26QA217 Salient Characteristics - draft.docx
DOCX document 33 KB Posted
- Attached to
- Fire Department Entry Control System
- Solicitation number
- FA462026QA217-1
About this file
This is a Salient Characteristics document for Building 3 Access Control System (ACS) installation at Fairchild Air Force Base, scheduled for delivery and installation by 10 March 2026. The contractor shall deliver and install a standalone ACS with Premise Control Units (PCU), uninterrupted power supply, panel batteries, laser jet printer, duplex badge printer, and provide access control and badge training. The Government will receive shipment at 1001 West Boston Ave, Building 3, Fairchild AFB, WA 99011, with normal operations Monday through Friday 7am-4pm, excluding federal holidays. Services are not classified as mission essential during crises per DoDI 1100.22.
The software must run on a Windows 10 server/computer with dual HDMI ports and four USB slots, capable of independent alarm activations, remote door unlocking, individual or group locking, and administrator-controlled device naming. The system must display live card access activity including unknown cards, restricted users, invalid times, access grants, and duress indicators with associated photos. It requires administrator and operator-defined roles, programmable door schedules (minimum 25 doors), unlock times ranging from 1-15 seconds, and the ability to switch between Level I (swipe only) and Level II (swipe plus four-digit PIN) access. The contractor shall supply 200 proximity cards (26-bit format H10301, site code 65, sequence 1001), 10 Level II card readers with two spares, one enrollment reader, compatible CAC readers, sufficient electric strikes and 600-1200 lb magnetic locks with request exit sensors, emergency overrides, and push buttons. PCUs must be FIPS/NIST compliant with AES 128 or 256-bit encryption and four-hour battery backup. Supporting equipment includes one laser jet printer, one duplex color badge printer, one badge camera with tripod, 100 blank PVC cards, one unmanaged network switch with 25% spare ports, one KVM with HDMI and USB ports, and one external hard drive for database backup and system restoration. Power supplies must support magnetic locks and electric strikes independently with two backup batteries per supply, and two UPS units—one for the computer/server/monitor/switch and one for 30-minute KVM/monitor backup.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 26QA217 Attach 2. SOW.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SALIENT CHARACTERISTICS
BLDG. 3 ACS INSTALLATION
10 MARCH 2026
1.0. DESCRIPTION OF SERVICES. The contractor shall deliver and install standalone access control system (ACS), Premise Control Units (PCU), uninterrupted power supply, panel batteries, laser jet printer, duplex badge printer, and access control and badge training for Bldg. 3.
2.0. SCOPE OF WORK DEFINED. The contractor will deliver via the approved shipping method and install ACS equipment.
3.0. GOVERNMENT FACILITIES AND SERVICES. The Government shall receive shipment at 1001 West Boston Ave, Bldg. 3 Fairchild AFB WA, 99011, Fairchild AFB.
4.0. GENERAL INFORMATION.
4.1. Hours of Operation: Normal hours of operation are Monday through Friday 7am – 4pm
| January 1 | New Years Day | |||
| 3rd Monday in January | Martin Luther King, Jr. Day | |||
| 3rd Monday in February | President’s Day | |||
| Last Monday in May | Memorial Day | |||
| 3rd Week of June | Juneteenth Day | |||
| July 4 | Independence Day | |||
| 1st Monday in September | Labor Day | |||
| 2nd Monday in October | Columbus Day | |||
| November 11 | Veterans Day | |||
| 4th Thursday in November | Thanksgiving Day | |||
| December 25 | Christmas |
5.0. CONTINUATION OF MISSION ESSENTIAL FUNCTIONS. IAW DoDI 1100.22 (Policy and Procedures for Determining Workforce Mix), and any applicable Air Force implementation, unless otherwise directed by an authorized Government representative, it is determined that services provided under this contract are not mission essential for performance during a crisis.
6.0. SALIENT CHARACTERISTICS.
6.1. Contractor/vendor will provide and install:
6.1.1. Software Capabilities:
6.1.1.1. Provide one (1) server/computer system minimum Windows 10 with applicable Microsoft license and associated Windows updates with two High-Definition Multimedia Interface (HDMI) ports and four Universal Serial Bus (USB) slots.
6.1.1.2. Must show independent alarm activations. An operator must be able to acknowledge and reset alarms.
6.1.1.3. Must be able to remotely unlock doors and individually lock or as a group all doors.
6.1.1.4. An administrator must have software permissions to change naming ACS devices, i.e., Front door to Main Entrance, and so on.
6.1.1.5. Must show live card access activity, defined (naming conventions may be different with other software) as a minimum: Unknown card (not programmed/register), User Restricted (deny access), Invalid Time (register proximity card swiping outside the prescribed date and time), access granted, duress (indicated as such), and the applicable photo of person with a registered/enrolled proxy card.
6.1.1.6. Must have administrator and operator defined roles/permissions that the administrator (owning user agency) can program.
6.1.1.7. Program door locks for an unlock schedule, Monday through Sunday, at any given time. Must have minimum of 25 door schedule to be programmed individually for each respective door.
6.1.1.8. Program unlock door times ranging from 1 to 15 seconds.
6.1.1.9. An administrator must be able to program the software from Level I (swipe only) to Level II (swipe + entering a four-digit personal identification number) or from Level II to Level I at a moment’s notice for each card reader.
6.1.1.10. Run operator, administrator, and technical reports about components installed, user accessing doors with date and time stamps, and sensor activity.
6.1.1.11. Must have site/facility code requirement and be able to enter a four-digit personal identification number (PIN) by individual user.
6.1.1.12. Must have data fields of last and first name, and store associated picture.
6.1.1.13. For the individual profile, there must be three to five customizable text boxes where the administrator can add customized text with a fillable text box up to 100 characters.
6.1.1.14. Support Wiegand card bits, 26, 32, and 48.
6.1.1.15. Must support additional door programming for an additional 10 doors.
6.2.1. Access Control Card Capabilities:
6.2.1.1. Proximity cards must be compatible with current base-wide system and other HID card readers (26-bit, Format H10301, HID P/N: 2000PGGMN HID S/0: 11102089937-1).
6.2.1.2. Card readers must be able to read Government issued Common Access Card (CAC).
6.2.1.3. The contractor shall provide 200 proximity cards, 26-bit format H10301, site code 65, and starting sequence 1001.
6.2.1.4. Contractor shall install and provide 10 card readers as Level II, meaning proximity swipe with keypad in one card reader. Provide two (2) spare Level II card readers compatible with ACS server/computer.
6.2.1.5. Card readers must have color changing light emitting diode (LED) to display red when door is locked and green when unlocked.
6.2.1.6. Must be able to enter and register a duress PIN.
6.2.1.9. Provide one (1) enrollment reader to register proximity cards and CACs. This reader will be on its own desktop stand.
6.2.1.10. Supply sufficient applicable electric strikes.
6.2.1.11. Supply sufficient applicable 600 or 1200 lb. Magnetic locks.
6.2.1.12. Provide sufficient Passive Infrared Request Exits (REX) for each respective magnetic lock. Each respective REX will have adjustable passive Infrared eye to determine door unlock range for each magnetic lock.
6.2.1.13. Provide sufficient emergency overrides with each magnetic lock. Emergency Overrides will be wired and programmed to report a separate alarm when depressed. EOs do need to produce an audible siren.
6.2.1.14. Provide two (2) push buttons for unlocking two card reader doors.
6.3.1. Premise Control Unit (PCU):
6.3.1.1. Must be Federal Information Processing Standards (FIPS) and National Institute of Standards and Technology (NIST) compliant, Advanced Encryption Standard (AES) 128 or 256 bit, and the contractor must provide evidentiary documentation.
6.3.1.2. Must provide sufficient PCUs supporting magnetic locks, electric strikes, and electric crash bar.
6.3.1.3. Provide two (2) spare PCUs compatible with ACS computer/server.
6.3.1.4. Must have two (2) battery backup power for 4 hours.
6.3.1.5. Provide one (1) keypad to communicate with PCU.
6.4.1. Supporting Equipment:
6.4.1.1. Provide one (1) laser jet printer compatible with ACS server/computer.
6.4.1.2. Provide one (1) badge duplex color printer compatible with ACS server/computer.
6.4.1.3. Provide one (1) badge camera compatible with ACS server/computer. Provide one (1) tripod with collapsable legs for badge camera.
6.4.1.4. Provide 100 blank PVC cards for badge printer.
6.4.1.5. Provide one (1) unmanaged network switch with 25% spare Category 5e/6 ports.
6.4.1.6. Provide one (1) keyboard, video, and mouse (KVM) HDMI and two (2) USB ports.
6.4.1.7. Provide one (1) external hard drive for database backup. Hard drive size must be able to hold database, badge camera pictures, and a total backup of server/computer system for complete restoration.
6.5.1. Power Supplies:
6.5.1.1. Provide sufficient magnetic locks and electric strikes power supplies.
6.5.1.2. Magnetic locks and electric strikes/electric crash bar must have their own power supplies.
6.5.1.3. Provide two (2) backup batteries per power supply.
6.5.1.4. Provide sufficient power supplies with fire trigger output only for magnetic power supplies.
6.6.1. Uninterrupted Power Supply (UPS):
6.6.1.1. Provide one (1) UPS for computer/server, monitor, and unmanage switch. UPS must also have surge only plugins for laser and badge duplex color printers.
6.6.1.2. Provide one (1) UPS for 30 minutes battery backup to support KVM and monitor.