This document contains the architectural drawings and specifications for the repair of racquetball courts in Building S-1715 at Camp Casey. The key details are:

The scope of work includes replacing deteriorated ceiling panels, wall panels, lighting fixtures, and HVAC diffusers. It also requires grinding and refinishing the existing wood flooring and replacing thresholds. The drawings provide the floor plan, interior finish schedule, and construction details for these repairs.

The related federal contract opportunity is Solicitation W90VN824R0071 issued by the Department of the Army Materiel Command Army Contracting Command for the "MATOC Racquetball Court Repair Casey" project. The contract requires the contractor to provide all necessary resources to perform the repair work in accordance with the provided Statement of Work, specifications, and drawings.

View the file

Other files

File Type Posted
W90VN924R0071_SF30.pdf PDF
Solicitation_0071.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SCHEDULE OF DRAWINGS

RING NO. REF. NO.REVISION STATUSDWG. NO. SHT. NO.REF. NO.

T - 1

RING NO. DESCRIPTION OF DRAWINGS

TITLE SHEET

DWG. NO. SHT. NO. DESCRIPTION OF DRAWINGS REVISION STATUS

TITLE SHEET

T-1

A - 1

A - 2

ARCHITECTURAL

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15333, APO AP 96205-5333

DPW, ENGINEERING SERVICES DIVISON, DESIGN BRANCH

HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN-CASEY

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

FLOOR PLAN, GENERAL NOTES AND SCOPE OF WORK

SECTION DETAIL, INTERIOR FINISH SCHEDULE AND MATERIAL SCHEDULE

262280

BLDG. S-1715

REPAIR RACQUETBALL COURTS

CAMP CASEYKIM, YK

BLDG. S-1715

REPAIR RACQQUETBALL COURTS

FEWR NO. 262280, CP CASEY

MANUFACTURES INDICATED.

PURPOSES ONLY. AND NOT INTENDED TO LIMIT SELECTIONS TO PRODUCTS OF THE

COLORS AND PATTERNS LISTED BY MANUFACTURES ARE FOR BIDDING IDENTIFICATION 1.

ADJACENT AREAS AS DIRECTED BY THE CONTRACTING OFFICER REPRESENTATIVE (COR).

CAUSED BY THIS PROJECT AND SHALL REPAIR THE DAMAGES TO MATCH UP TO

CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGES MADE TO EXISTING AREAS

FOR APPROVAL.

CONTRACTOR ACCORDING TO ACTUAL FIELD CONDITION AND SUBMITED TO COR

CONDITION. IN THAT CASE, SHOP DRAWINGS SHALL BE PREPARED AT THE SITE BY THE

SOME DETAILS SHOWN ON CONTRACT DRAWINGS MAY NOT COINCIDE WITH THE FIELD

8.

FOR APPROVAL.

CONTRACTOR SHALL SUBMIT MANUFACTURER'S INSTALLATION SHOP DRAWINGS TO COR

2.

3.

4.

5.

6.

7.

CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER

IF THERE ARE ANY CONFLICTS WITHIN THE CONTRACT DOCUMENT. THE GENERAL

AND DIMENSIONS PRIOR TO COMMENCING ANY CONSTRUCTION OR RENOVATION.

THE CONTRACTOR SHALL BE RESPONSIBLE IN VERIFYING ALL EXISTING CONDITION

ADDITIONAL COST TO THE GOVERNMENT.

EQUIPMENT, ETC), ELECTRICAL, TELEPHONE AND FIRE ALARM SYSTEM WITHOUT

THE INSTALLATION AND/OR REPLACEMENT OF MECHANICAL (PLUMBING, HEATING,

ITEMS, CUT, PATCH AND RESTORE WALLS, FLOORS AND CEILING WHERE REQUIRED FOR

THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVE/REINSTALL ANY OBSTRUCTED

GENERAL NOTES

1.

2.

SCOPE OF WORKS (ARCHITECTURAL WORKS)

REPAIR / MAINTENANCE (K) WORKS

SCALE: 1/100

A-1

ARCHITECTURAL

COURT DESIGN WILL BE FOLLOWED AS CURRENT FLOOR DESIGN AND GYM MANAGER.

W

W

D D

FEC

,5

,5

,5

,5

6,096

9144,267914

FLOOR PLAN @ RACQUETBALL COURT

,1

14' 3'3'

ON THE WALL

NO LINES AREA ALLOWED

AND SOLID RED IN COLOR

ALL LINES ARE 1.5" WIDE

ROOM NO. 112

RACQUETBALL COURT

KEY PLAN @ BLDG S-1715

CLEAN EXST GLASS WALL & DOOR

ON EACH EDGES

REPLACE SEALANT CAULKING

7.

262280

BLDG. S-1715

REPAIR RACQUETBALL COURTS

CAMP CASEYKIM, YK

3.

CLEAN EXISTING GLASS WALL AND GLASS DOOR.4.

5.

ON FLOOR PLAN.

REPLACE DETERIORATED EXSITING SEALNT CAULKING WITH NEW FOR ALL EDGES AS SHOWN

COMPONENTS AS SHOWN ON FLOOR PLAN, DETAIL DRAWINGS & INTERIOR FINISH SCHEDULE.

INCLUDING NEW SUSPENDED CEILING SYSTEM, METAL FRAMINGS AND ASSOCIATED

REPLACE DETERIORATED EXISTING CEILING PANELS FOR RACQUET BALL COURT WITH NEW

REPLACE DETERIORATED EXSITING LINEAR SLOT DIFFUSERS WITH NEW.6.

RACQUETBALL COURT LIGHTING FIXTURES. (7 SETS, 2' X 2', 117 WATTS @ 12,075 LUMENS )

REPLACE DETERIORATED EXSITING LIGHTING FIXTURES WITH NEW IMPACT RESISTANT LED

REPLACE EXST WALL PANEL & CEILING PANEL

APPLY URETHANE FINISH

GRIND WOODEN FLOORING &

REPLACE THRESHOLDS

PER REGULATIONS AS SHOWN ON FLOOR PLAN & INTERIOR FINISH SCHEDULE.

APPLY URETHANE FINISH PER MANUFACTURERS SPECIFICATIONS AND LINE MARKING

GRIND THE EXISTING WOOD FLOORING TO FLATTEN THE PEELED SURFACES AND

AS SHOWN ON FLOOR PLAN, DETAIL DRAWINGS & INTERIOR FINISH SCHEDULE.

INCLUDING NEW METAL STUDS, METAL CHANNELS AND ASSOCIATED COMPONENTS

REPLACE DETERIORATED EXISTING WALL PANELS FOR RACQUET BALL COURT WITH NEW

AND SCOPE OF WORK

FLOOR PLAN, GENERAL NOTES

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15333, APO AP 96205-5333

DPW, ENGINEERING SERVICES DIVISON, DESIGN BRANCH

HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN-CASEY

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

SCALE: 1/2

6 THK OPENING FOR AIR VENT

EXST CONCRETE SLAB

A-2

ARCHITECTURAL

262280

BLDG. S-1715

REPAIR RACQUETBALL COURTS

CAMP CASEYKIM, YK

ROOM NAMES

INTERIOR FINISH SCHEDULE

FLOOR BASE WALLS CEILING

FINISH COLOR FINISH COLOR FINISH COLOR FINISH COLOR HEIGHT

MAT'L

EXST

MAT'L

NEW

MAT'L

EXST

MAT'L

NEW

MAT'L

EXST

MAT'L

NEW

MAT'L

NEW

MAT'L

EXST

6100WF - CP

FLOOR MATERIAL/COLOR

UT-1

OR APPROVED EQUAL

RACQUETBALL COURT

REMARKS

ROOM NOS

- - - - GLASS/WP CP

FINISH SCHEDULE NOTES :

PAINT -/WP -/F.F. F.F.

SCALE:

PICTURES

N/A

APPLY URETHANE FINISH

GRIND WOODEN FLOORING &

CEILING PANEL

REPLACE EXST WALL PANEL &

REPLACE LINEAR SLOT DIFFUSERS REMAIN EXST SPRINKLER HEADS

* IMPACT RESISTANT TYPE (LED)

REPLACE LIGHTING FIXTURES

WALL MATERIAL/COLOR

WP-1

OR APPROVED EQUAL

ALLIED PRODUCTS, LLC

: CEILING PANELCP-1

ALLIED PRODUCTS, LLC

THE MANUFACTURERS STANDARD MUST APPROACH.

THE SELECTIONS SERVE ONLY TO INDICATE THE COLOR WHICH

COLOR IS NOT REQUIRED.

OF PRODUCTS. AN EXACT MATCH OF THE MANUFACTURERS

PURPOSES ONLY AND ARE NOT INTENDED TO LIMIT SELECTIONS

MANUFACTURERS' COLORS LISTED ARE FOR IDENTIFICATION

CEILING MATERIAL/COLOR

-/WP-1 CP-1

: WALL PANEL

UT-1

: URETHANE PAINT LACQUER

TRANSPARENT COLOR

EXST 19 THK RUBBER PAD @ 300 OC

EXST 50 X 75 X 1200 WOOD SLEEPER @ 300 OC

CONC SLAB

MEMBRANE ON EXST

EXST 6 MIL POLYETHYLENE

(OPTIONAL BY MANUFACTURER)

EXST 12 THK PLYWOOD

TONGUE & GROOVE COURT WALL PANEL

REPLACE 1219 X 2438 X 28.5 THK

- CEILING : 16

- SIDE WALL : 22

- FRONT WALL : 28.5

* PANEL THICKNESS (OPTIONAL BY MANUFACTURER)

- CEILING : 16

- SIDE WALL : 22

- FRONT WALL : 28.5

* PANEL THICKNESS (OPTIONAL BY MANUFACTURER)

(OPTIONAL BY MANUFACTURER)

@400 O.C.(SIDE WALLS)

@300 O.C.(FRONT WALL)

THK150 METAL STUD

W/HIGH-DENSITY PARTICLEBOARD

W/85 lbs/cf, AVERAGE DENSITY

W/VELVET TEXTURE FINISH, 0.5THK

HIGH-PRESSURE PLASTIC LAMINATE

OR APPROVED EQUAL

W/HIGH-DENSITY PARTICLEBOARD

W/85 lbs/cf, AVERAGE DENSITY

W/VELVET TEXTURE FINISH, 0.5THK

HIGH-PRESSURE PLASTIC LAMINATE

GRINDING & URETHANE REFINISH

EXST 20 THK MAPLE FLOORING/

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15333, APO AP 96205-5333

DPW, ENGINEERING SERVICES DIVISON, DESIGN BRANCH

HEADQUARTERS, UNITED STATES ARMY GARRISON, YONGSAN-CASEY

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

SECTION DETAIL

SCHEDULE AND MATERIAL SCHEDULE

SECTION DETAIL, INTERIOR FINISH

MATERIAL SCHEDULE

T-01
A-01
A-02

File details come from the government source that posted it. Updated .