About this file

This document set consists of architectural drawings and specifications issued by the County of Kenosha, Wisconsin, for the 2026 Building Envelope Restoration Project at Kemper Center (6501 3rd Avenue, Kenosha, WI 53143). The project scope encompasses comprehensive restoration and rehabilitation of the building's exterior, including masonry repointing, brick replacement, limestone restoration, window and door restoration and replacement, steel lintel painting, and miscellaneous exterior painting. The drawings were issued for bid on January 7, 2026, and were prepared by InSite Consulting Architects of Madison, Wisconsin. The project includes work across multiple building elevations (east, west, and north) and courtyard areas, with detailed specifications for restoration of approximately 100 random brick replacements throughout the project, full repointing of masonry joints, removal and resetting of coping stones, and restoration or replacement of windows and doors across multiple locations identified as W001 through W302 and D101 through D104.

All work must comply with the latest Wisconsin Building Code and local standards. Contractors are required to verify all dimensions and site conditions prior to bid submission and must document existing conditions that may be impacted by work operations. The contract mandates that contractors coordinate with building facility managers regarding any required system shutdowns, protect landscaping and existing features within project limits, and immediately report any discrepancies between drawings and field conditions to the architect. Materials specifications include Douglas fir for wood replacements, stainless steel fasteners and counterflashing, copper and lead flashing, self-adhering membrane flashing, and all finishes must match existing colors and profiles. Bidders must include all labor, materials, equipment, and services necessary for project completion, with the understanding that any work not specifically detailed will be subject to change order.

View the file

Other files

File Type Posted
2604 Bid Documents.pdf PDF
2604 Addendum 1.pdf PDF
Vendor Responsibility Form Construction.pdf PDF
2604 Specifications.pdf PDF
2604 Addendum 2.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Kemper Center 6501 3rd Ave Kenosha, WI 53143

B U

IL

D

IN

G

E N

VE

LO

PE

R

ES

TO

R

AT

IO

N

KE

M

PE

R

C

EN

TE

R

KE

N

O

SH

A C

O U

N

TY

ISSUE FOR BID

01/07/2026

InSite Consulting Architects 744 Williamson St. / STE 101 Madison, Wisconsin 53703 608-204-0825 608-531-1533 (fax) info@icsarc.com

THE FOLLOWING GENERAL NOTES SHALL

APPLY :

ALL DESIGN AND CONSTRUCTION SHALL BE IN ACCORDANCE

WITH ALL LOCAL AND STATE OF WISCONSIN BUILDING CODE

LATEST EDITION.

CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF, AND

COORDINATION WITH, ALL DIMENSIONS SHOWN ON THESE

DRAWINGS RELATIVE TO EXISTING CONDITIONS PRIOR

TO SUBMITTING BID.

THE DRAWINGS REPRESENT THE ON-SITE CONDITIONS TO THE

EXTENT KNOWN. THE BIDDERS ARE REQUIRED TO INFORM

THE ARCHITECT AND OWNER OF ANY OBSERVED

DISCREPANCIES BETWEEN THE DRAWINGS AND THE ON-SITE

CONDITIONS PRIOR TO SUBMITTING THEIR BID.

CONTRACTOR SHALL REPORT IMMEDIATELY TO THE

ARCHITECT ALL DISCREPANCIES VERBALLY, A WRITTEN

REPORT SHOULD PROMPTLY FOLLOW. CONTRACTOR SHALL

CEASE WORK IN THE AFFECTED AREA UNTIL DIRECTED BY

THE ARCHITECT. IF A CHANGE IN SCOPE OR TIME IS EXPECTED

PROVIDE A DETAILED CHANGE REQUEST FOR ARCHITECT'S

REVIEW.

THE CONTRACTOR SHALL PROVIDE ALL METHODS AND

EQUIPMENT FOR PROTECTING THE BUILDING, ALL

MATERIALS, AND PERSONNEL FROM FIRE OR OTHER DAMAGE

PRIOR TO STARTING. THE CONTRACTOR SHALL SUBMIT THE

APPROVED METHODS AND EQUIPMENT IN WRITING FOR THE

OWNER AND ARCHITECT'S REVIEW PRIOR TO STARTING

WORK.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

2026 BUILDING ENVELOPE RESTORATION

KEMPER CENTER

KENOSHA COUNTY BID #2604

THE CONTRACTOR SHALL COMPLY WITH ALL SAFETY AND

HEALTH LAWS AND REGULATIONS.

PROTECT TREES, SHRUBS, LAWNS, AND OTHER FEATURES

WITHIN PROJECT LIMITS. RESTORE DAMAGED FEATURES TO

ORIGINAL CONDITION. THE CONTRACTOR SHALL DOCUMENT ALL

EXISTING CONDITIONS THAT MAY BE IMPACTED BY THE

CONTRACTOR'S OPERATIONS.

THE CONTRACTOR SHALL COORDINATE WITH BUILDING FACILITY

MANAGER(S) ANY BUILDING SYSTEMS SHUT DOWNS PRIOR TO

SCHEDULED SYSTEM SHUT DOWNS.

BY SUBMITTING BID, THE BIDDERS ACKNOWLEDGE THAT THEY

HAVE VERIFIED ALL DIMENSIONS, DETAILS AND OTHER

CONDITIONS PRIOR TO SUBMITTING THEIR BID.

THE BIDDERS SHALL INCLUDE IN THEIR BID ALL WORK,

MATERIALS, SERVICES, ETC., NECESSARY TO THE SUCCESSFUL

COMPLETION OF THE PROJECT.

KENOSHA, WI

SHEET INDEX

TS TITLE SHEET

A1 OVERALL SCOPE LOCATIONS

A2 EAST ELEVATION SCOPE

A3 EAST ELEVATION SCOPE

A4 NORTH ELEVATION SCOPE

A5 WEST ELEVATION SCOPE - COURTYARD

A6 NORTH ELEVATION SCOPE - COURTYARD

A7 EAST ELEVATION SCOPE - COURTYARD

A8 EAST ELEVATION SCOPE - COURTYARD

A9 CHIMNEY SCOPE

A10 TYPICAL WINDOW RESTORATION SCOPE

A11 WINDOW REPLACEMENT TYPES AND SCHEDULE

A12 TYPICAL WINDOW REPLACEMENT DETAILS

A13 DOOR REPLACEMENT SCOPE

A14 DOOR REPLACEMENT SCOPE

A15 DOOR SCHEDULE

A16 CAP FLASHING DETAIL

A17 TYPICAL MASONRY DETAILS

PROJECT LOCATION

N

TITLE SHEET

TS

Kenosha, WI 53143

B U

IL

D

IN

G

E N

VE

LO

PE

R

ES

TO

R

AT

IO

N

KE

M

PE

R

C

EN

TE

R

KE

N

O

SH

A C

O U

N

TY

ISSUE FOR BID

01/07/2026

InSite Consulting Architects 744 Williamson St. / STE 101 Madison, Wisconsin 53703 608-204-0825 608-531-1533 (fax) info@icsarc.com

BIRD'S EYE PHOTO LOOKING EAST3

A0

OVERALL SCOPE LOCATIONS

A1

KEY:

AREA OF SCOPE

BIRD'S EYE PHOTO LOOKING SOUTH2

A0

BIRD'S EYE PHOTO LOOKING WEST1

A0

SEE SHEET

A2

SEE SHEET

A2

SEE SHEET

A4

SEE SHEET

A3

SEE SHEET

A6

SEE SHEET

A7

SEE SHEET

A5

SEE SHEET

A5

Kenosha, WI 53143

B U

IL

D

IN

G

E N

VE

LO

PE

R

ES

TO

R

AT

IO

N

KE

M

PE

R

C

EN

TE

R

KE

N

O

SH

A C

O U

N

TY

ISSUE FOR BID

01/07/2026

InSite Consulting Architects 744 Williamson St. / STE 101 Madison, Wisconsin 53703 608-204-0825 608-531-1533 (fax) info@icsarc.com

A2

EAST ELEVATION SCOPE

BRICK REPLACEMENT

1. ASSUME REPLACEMENT OF 100

RANDOM BRICK. (ENTIRE

PROJECT)

2. REPLACEMENT BRICK SHALL

MATCH EXISTING. FINAL SIZE

AND COLOR SHALL BE BY

ARCHITECT.

KEY:

100% REPOINT

CONTROL JOINT

D000 DOOR TAG

W000 WINDOW TAG

EAST ELEVATION PHOTO - RECTORY1

A2

DESIGN NOTES:

100% REPOINT THIS AREA

REMOVE, FLASH, AND RESET

COPING STONES

REPLACE BACKER ROD AND

SEALANT IN EXISTING CONTROL

JOINT

100% REPOINT BRICK HEAD,

JAMB/RETURNS

REPLACE EXISTING DOOR AND

FRAME.

SCRAPE, CLEAN, PRIME, PAINT

EXISTING STEEL LINTEL. MATCH

EXISTING COLOR

SCRAPE, CLEAN, PRIME, PAINT

EXISTING WOOD TRIM. MATCH

EXISTING COLOR

SCRAPE, CLEAN, PRIME, PAINT

EXISTING DOOR AND FRAME.

REPAIR WOOD AS REQUIRED.

MATCH EXISTING COLORS.

REPLACE PERIMETER SEALANT.

REPLACE WEATHERSTRIPPING

(ALL SIDES) AND ALUMINUM

THRESHOLD

SCRAPE, CLEAN, PRIME, PAINT

EXISTING WINDOW FRAME AND

STORM. MATCH EXISTING COLORS.

NEW SEALANT AROUND PERIMETER

OF FRAME - PAINT TO MATCH

EXISTING COLOR

REPLACE BRICK THIS LOCATION

TYPICAL WINDOW RESTORATION

SCOPE. SEE SHEET A10

REPLACE EXISTING WINDOW. SEE

SHEETS A11 & A12

13 REMOVE EXISTING LOUVER AND

INFILL OPENING. BRICK TO MATCH

EXISTING WALL

SCRAPE CLEAN, PRIME, PAINT

DORMER AND WINDOW (FRAME AND

SASHES). REPAIR WOOD AS

REQUIRED. NEW SEALANT AROUND

PERIMETER OF FRAME - PAINT TO

MATCH EXISTING COLOR

EAST ELEVATION PHOTO - ARMITAGE HALL2

A2

D101

D102

PROVIDE WOOD

DUTCHMAN

PROVIDE WOOD

SASH CLOSURE -

PAINT TO MATCH

SASH

100% REPOINT

1SEE PHOTO

3/A2

ENLARGED PHOTO @ WINDOW3

A2

PHOTO4

A2

REPLACE DAMAGED

BRICK - MATCH

EXISTING

SEE PHOTO

4/A2

Kenosha, WI 53143

B U

IL

D

IN

G

E N

VE

LO

PE

R

ES

TO

R

AT

IO

N

KE

M

PE

R

C

EN

TE

R

KE

N

O

SH

A C

O U

N

TY

ISSUE FOR BID

01/07/2026

InSite Consulting Architects 744 Williamson St. / STE 101 Madison, Wisconsin 53703 608-204-0825 608-531-1533 (fax) info@icsarc.com

A3

EAST ELEVATION SCOPE

EAST ELEVATION PHOTO - ARMITAGE HALL1

A3

BRICK REPLACEMENT

1. ASSUME REPLACEMENT OF 100

RANDOM BRICK. (ENTIRE

PROJECT)

2. REPLACEMENT BRICK SHALL

MATCH EXISTING. FINAL SIZE

AND COLOR SHALL BE BY

ARCHITECT.

KEY:

100% REPOINT

CONTROL JOINT

D000 DOOR TAG

W000 WINDOW TAG

DESIGN NOTES:

100% REPOINT THIS AREA

REMOVE, FLASH, AND RESET

COPING STONES

REPLACE BACKER ROD AND

SEALANT IN EXISTING CONTROL

JOINT

100% REPOINT BRICK HEAD,

JAMB/RETURNS

REPLACE EXISTING DOOR AND

FRAME.

SCRAPE, CLEAN, PRIME, PAINT

EXISTING STEEL LINTEL. MATCH

EXISTING COLOR

SCRAPE, CLEAN, PRIME, PAINT

EXISTING WOOD TRIM. MATCH

EXISTING COLOR

SCRAPE, CLEAN, PRIME, PAINT

EXISTING DOOR AND FRAME.

REPAIR WOOD AS REQUIRED.

MATCH EXISTING COLORS.

REPLACE PERIMETER SEALANT.

REPLACE WEATHERSTRIPPING

(ALL SIDES) AND ALUMINUM

THRESHOLD

SCRAPE, CLEAN, PRIME, PAINT

EXISTING WINDOW FRAME AND

STORM. MATCH EXISTING COLORS.

NEW SEALANT AROUND PERIMETER

OF FRAME - PAINT TO MATCH

EXISTING COLOR

REPLACE BRICK THIS LOCATION

TYPICAL WINDOW RESTORATION

SCOPE. SEE SHEET A10

REPLACE EXISTING WINDOW. SEE

SHEETS A11 & A12

13 REMOVE EXISTING LOUVER AND

INFILL OPENING. BRICK TO MATCH

EXISTING WALL

SCRAPE CLEAN, PRIME, PAINT

DORMER AND WINDOW (FRAME AND

SASHES). REPAIR WOOD AS

REQUIRED. NEW SEALANT AROUND

PERIMETER OF FRAME - PAINT TO

MATCH EXISTING COLOR

PHOTO2

A3

PHOTO3

A3

PHOTO4

A3

PHOTO5

A3

SEE PHOTO

3/A3

SEE PHOTO

2/A3

SEE PHOTO

4/A3

SEE PHOTO

5/A3

REPLACE DAMAGED

BRICK - MATCH

EXISTING

REPLACE DAMAGED

BRICK - MATCH

EXISTING

Kenosha, WI 53143

B U

IL

D

IN

G

E N

VE

LO

PE

R

ES

TO

R

AT

IO

N

KE

M

PE

R

C

EN

TE

R

KE

N

O

SH

A C

O U

N

TY

ISSUE FOR BID

01/07/2026

InSite Consulting Architects 744 Williamson St. / STE 101 Madison, Wisconsin 53703 608-204-0825 608-531-1533 (fax) info@icsarc.com

A4

NORTH ELEVATION SCOPE

NORTH ELEVATION PHOTO - ARMITAGE HALL1

A4

BRICK REPLACEMENT

1. ASSUME REPLACEMENT OF 100

RANDOM BRICK. (ENTIRE

PROJECT)

2. REPLACEMENT BRICK SHALL

MATCH EXISTING. FINAL SIZE

AND COLOR SHALL BE BY

ARCHITECT.

KEY:

100% REPOINT

CONTROL JOINT

D000 DOOR TAG

W000 WINDOW TAG

11 4

DESIGN NOTES:

100% REPOINT THIS AREA

REMOVE, FLASH, AND RESET

COPING STONES

REPLACE BACKER ROD AND

SEALANT IN EXISTING CONTROL

JOINT

100% REPOINT BRICK HEAD,

JAMB/RETURNS

REPLACE EXISTING DOOR AND

FRAME.

SCRAPE, CLEAN, PRIME, PAINT

EXISTING STEEL LINTEL. MATCH

EXISTING COLOR

SCRAPE, CLEAN, PRIME, PAINT

EXISTING WOOD TRIM. MATCH

EXISTING COLOR

SCRAPE, CLEAN, PRIME, PAINT

EXISTING DOOR AND FRAME.

REPAIR WOOD AS REQUIRED.

MATCH EXISTING COLORS.

REPLACE PERIMETER SEALANT.

REPLACE WEATHERSTRIPPING

(ALL SIDES) AND ALUMINUM

THRESHOLD

SCRAPE, CLEAN, PRIME, PAINT

EXISTING WINDOW FRAME AND

STORM. MATCH EXISTING COLORS.

NEW SEALANT AROUND PERIMETER

OF FRAME - PAINT TO MATCH

EXISTING COLOR

REPLACE BRICK THIS LOCATION

TYPICAL WINDOW RESTORATION

SCOPE. SEE SHEET A10

REPLACE EXISTING WINDOW. SEE

SHEETS A11 & A12

13 REMOVE EXISTING LOUVER AND

INFILL OPENING. BRICK TO MATCH

EXISTING WALL

SCRAPE CLEAN, PRIME, PAINT

DORMER AND WINDOW (FRAME AND

SASHES). REPAIR WOOD AS

REQUIRED. NEW SEALANT AROUND

PERIMETER OF FRAME - PAINT TO

MATCH EXISTING COLOR

ENLARGED PHOTO - ARMITAGE HALL2

A4

SEE PHOTO

2/A4

100% REPOINT

SEE PHOTO

2/A9

Kenosha, WI 53143

B U

IL

D

IN

G

E N

VE

LO

PE

R

ES

TO

R

AT

IO

N

KE

M

PE

R

C

EN

TE

R

KE

N

O

SH

A C

O U

N

TY

ISSUE FOR BID

01/07/2026

InSite Consulting Architects 744 Williamson St. / STE 101 Madison, Wisconsin 53703 608-204-0825 608-531-1533 (fax) info@icsarc.com

A5

WEST ELEVATION SCOPE -

COURTYARD

WEST ELEVATION PHOTO- ARMITAGE HALL

BRICK REPLACEMENT

1. ASSUME REPLACEMENT OF 100

RANDOM BRICK. (ENTIRE

PROJECT)

2. REPLACEMENT BRICK SHALL

MATCH EXISTING. FINAL SIZE

AND COLOR SHALL BE BY

ARCHITECT.

KEY:

100% REPOINT

CONTROL JOINT

D000 DOOR TAG

W000 WINDOW TAG

A5

8 8

1 1

DESIGN NOTES:

100% REPOINT THIS AREA

REMOVE, FLASH, AND RESET

COPING STONES

REPLACE BACKER ROD AND

SEALANT IN EXISTING CONTROL

JOINT

100% REPOINT BRICK HEAD,

JAMB/RETURNS

REPLACE EXISTING DOOR AND

FRAME.

SCRAPE, CLEAN, PRIME, PAINT

EXISTING STEEL LINTEL. MATCH

EXISTING COLOR

SCRAPE, CLEAN, PRIME, PAINT

EXISTING WOOD TRIM. MATCH

EXISTING COLOR

SCRAPE, CLEAN, PRIME, PAINT

EXISTING DOOR AND FRAME.

REPAIR WOOD AS REQUIRED.

MATCH EXISTING COLORS.

REPLACE PERIMETER SEALANT.

REPLACE WEATHERSTRIPPING

(ALL SIDES) AND ALUMINUM

THRESHOLD

SCRAPE, CLEAN, PRIME, PAINT

EXISTING WINDOW FRAME AND

STORM. MATCH EXISTING COLORS.

NEW SEALANT AROUND PERIMETER

OF FRAME - PAINT TO MATCH

EXISTING COLOR

REPLACE BRICK THIS LOCATION

TYPICAL WINDOW RESTORATION

SCOPE. SEE SHEET A10

REPLACE EXISTING WINDOW. SEE

SHEETS A11 & A12

13 REMOVE EXISTING LOUVER AND

INFILL OPENING. BRICK TO MATCH

EXISTING WALL

SCRAPE CLEAN, PRIME, PAINT

DORMER AND WINDOW (FRAME AND

SASHES). REPAIR WOOD AS

REQUIRED. NEW SEALANT AROUND

PERIMETER OF FRAME - PAINT TO

MATCH EXISTING COLOR

WEST ELEVATION PHOTO - ARMITAGE HALL2

A5

D103 D104

SEE PHOTO

1/A9

NOTE:

BRICK BELT COURSE

REPOINTING INCLUDES

BED JOINTS ON TOP

AND BOTTOM

1 1

SEE DETAIL

3/A17

Kenosha, WI 53143

B U

IL

D

IN

G

E N

VE

LO

PE

R

ES

TO

R

AT

IO

N

KE

M

PE

R

C

EN

TE

R

KE

N

O

SH

A C

O U

N

TY

ISSUE FOR BID

01/07/2026

InSite Consulting Architects 744 Williamson St. / STE 101 Madison, Wisconsin 53703 608-204-0825 608-531-1533 (fax) info@icsarc.com

NORTH ELEVATION SCOPE -

COURTYARD

A6

BRICK REPLACEMENT

1. ASSUME REPLACEMENT OF 100

RANDOM BRICK. (ENTIRE

PROJECT)

2. REPLACEMENT BRICK SHALL

MATCH EXISTING. FINAL SIZE

AND COLOR SHALL BE BY

ARCHITECT.

KEY:

100% REPOINT

CONTROL JOINT

D000 DOOR TAG

W000 WINDOW TAG

NORTH ELEVATION PHOTO - FOUNDERS HALL1

A6

4 4 4 4 4

12 11 11 11 11

1 1

DESIGN NOTES:

100% REPOINT THIS AREA

REMOVE, FLASH, AND RESET

COPING STONES

REPLACE BACKER ROD AND

SEALANT IN EXISTING CONTROL

JOINT

100% REPOINT BRICK HEAD,

JAMB/RETURNS

REPLACE EXISTING DOOR AND

FRAME.

SCRAPE, CLEAN, PRIME, PAINT

EXISTING STEEL LINTEL. MATCH

EXISTING COLOR

SCRAPE, CLEAN, PRIME, PAINT

EXISTING WOOD TRIM. MATCH

EXISTING COLOR

SCRAPE, CLEAN, PRIME, PAINT

EXISTING DOOR AND FRAME.

REPAIR WOOD AS REQUIRED.

MATCH EXISTING COLORS.

REPLACE PERIMETER SEALANT.

REPLACE WEATHERSTRIPPING

(ALL SIDES) AND ALUMINUM

THRESHOLD

SCRAPE, CLEAN, PRIME, PAINT

EXISTING WINDOW FRAME AND

STORM. MATCH EXISTING COLORS.

NEW SEALANT AROUND PERIMETER

OF FRAME - PAINT TO MATCH

EXISTING COLOR

REPLACE BRICK THIS LOCATION

TYPICAL WINDOW RESTORATION

SCOPE. SEE SHEET A10

REPLACE EXISTING WINDOW. SEE

SHEETS A11 & A12

13 REMOVE EXISTING LOUVER AND

INFILL OPENING. BRICK TO MATCH

EXISTING WALL

SCRAPE CLEAN, PRIME, PAINT

DORMER AND WINDOW (FRAME AND

SASHES). REPAIR WOOD AS

REQUIRED. NEW SEALANT AROUND

PERIMETER OF FRAME - PAINT TO

MATCH EXISTING COLOR

ENLARGED PHOTO @ SILL2

A6

ENLARGED PHOTO @ SILL3

A6

ENLARGED PHOTO @ SILL4

A6

SEE PHOTO

3/A6

SEE PHOTO

2/A6

SEE PHOTO

4/A6

W201

W202

W203 W204 W205

W301 W302

W001

NOTE: WOOD SPECIES FOR ALL

REPLACEMENT WOOD SHALL BE

DOUGLAS FIR. ANY SUBSTITUTION

MUST BE APPROVED BY ARCHITECT

PRIOR TO WORK

PROVIDE WOOD DUTCHMAN

PROVIDE WOOD DUTCHMAN

PROVIDE WOOD DUTCHMAN

Kenosha, WI 53143

B U

IL

D

IN

G

E N

VE

LO

PE

R

ES

TO

R

AT

IO

N

KE

M

PE

R

C

EN

TE

R

KE

N

O

SH

A C

O U

N

TY

ISSUE FOR BID

01/07/2026

InSite Consulting Architects 744 Williamson St. / STE 101 Madison, Wisconsin 53703 608-204-0825 608-531-1533 (fax) info@icsarc.com

EAST ELEVATION SCOPE -

COURTYARD

A7

BRICK REPLACEMENT

1. ASSUME REPLACEMENT OF 100

RANDOM BRICK. (ENTIRE

PROJECT)

2. REPLACEMENT BRICK SHALL

MATCH EXISTING. FINAL SIZE

AND COLOR SHALL BE BY

ARCHITECT.

KEY:

100% REPOINT

CONTROL JOINT

D000 DOOR TAG

W000 WINDOW TAG

EAST ELEVATION PHOTO - SOUTH CLOISTER - ALTERNATE NO. 11

A7

1 1

9 9

DESIGN NOTES:

100% REPOINT THIS AREA

REMOVE, FLASH, AND RESET

COPING STONES

REPLACE BACKER ROD AND

SEALANT IN EXISTING CONTROL

JOINT

100% REPOINT BRICK HEAD,

JAMB/RETURNS

REPLACE EXISTING DOOR AND

FRAME.

SCRAPE, CLEAN, PRIME, PAINT

EXISTING STEEL LINTEL. MATCH

EXISTING COLOR

SCRAPE, CLEAN, PRIME, PAINT

EXISTING WOOD TRIM. MATCH

EXISTING COLOR

SCRAPE, CLEAN, PRIME, PAINT

EXISTING DOOR AND FRAME.

REPAIR WOOD AS REQUIRED.

MATCH EXISTING COLORS.

REPLACE PERIMETER SEALANT.

REPLACE WEATHERSTRIPPING

(ALL SIDES) AND ALUMINUM

THRESHOLD

SCRAPE, CLEAN, PRIME, PAINT

EXISTING WINDOW FRAME AND

STORM. MATCH EXISTING COLORS.

NEW SEALANT AROUND PERIMETER

OF FRAME - PAINT TO MATCH

EXISTING COLOR

REPLACE BRICK THIS LOCATION

TYPICAL WINDOW RESTORATION

SCOPE. SEE SHEET A10

REPLACE EXISTING WINDOW. SEE

SHEETS A11 & A12

13 REMOVE EXISTING LOUVER AND

INFILL OPENING. BRICK TO MATCH

EXISTING WALL

SCRAPE CLEAN, PRIME, PAINT

DORMER AND WINDOW (FRAME AND

SASHES). REPAIR WOOD AS

REQUIRED. NEW SEALANT AROUND

PERIMETER OF FRAME - PAINT TO

MATCH EXISTING COLOR

Kenosha, WI 53143

B U

IL

D

IN

G

E N

VE

LO

PE

R

ES

TO

R

AT

IO

N

KE

M

PE

R

C

EN

TE

R

KE

N

O

SH

A C

O U

N

TY

ISSUE FOR BID

01/07/2026

InSite Consulting Architects 744 Williamson St. / STE 101 Madison, Wisconsin 53703 608-204-0825 608-531-1533 (fax) info@icsarc.com

EAST ELEVATION SCOPE -

COURTYARD

A8

BRICK REPLACEMENT

1. ASSUME REPLACEMENT OF 100

RANDOM BRICK. (ENTIRE

PROJECT)

2. REPLACEMENT BRICK SHALL

MATCH EXISTING. FINAL SIZE

AND COLOR SHALL BE BY

ARCHITECT.

KEY:

100% REPOINT

CONTROL JOINT

D000 DOOR TAG

W000 WINDOW TAG

EAST ELEVATION PHOTO - SOUTH CLOISTER - ALTERNATE NO. 11

A8

DESIGN NOTES:

100% REPOINT THIS AREA

REMOVE, FLASH, AND RESET

COPING STONES

REPLACE BACKER ROD AND

SEALANT IN EXISTING CONTROL

JOINT

100% REPOINT BRICK HEAD,

JAMB/RETURNS

REPLACE EXISTING DOOR AND

FRAME.

SCRAPE, CLEAN, PRIME, PAINT

EXISTING STEEL LINTEL. MATCH

EXISTING COLOR

SCRAPE, CLEAN, PRIME, PAINT

EXISTING WOOD TRIM. MATCH

EXISTING COLOR

SCRAPE, CLEAN, PRIME, PAINT

EXISTING DOOR AND FRAME.

REPAIR WOOD AS REQUIRED.

MATCH EXISTING COLORS.

REPLACE PERIMETER SEALANT.

REPLACE WEATHERSTRIPPING

(ALL SIDES) AND ALUMINUM

THRESHOLD

SCRAPE, CLEAN, PRIME, PAINT

EXISTING WINDOW FRAME AND

STORM. MATCH EXISTING COLORS.

NEW SEALANT AROUND PERIMETER

OF FRAME - PAINT TO MATCH

EXISTING COLOR

REPLACE BRICK THIS LOCATION

TYPICAL WINDOW RESTORATION

SCOPE. SEE SHEET A10

REPLACE EXISTING WINDOW. SEE

SHEETS A11 & A12

13 REMOVE EXISTING LOUVER AND

INFILL OPENING. BRICK TO MATCH

EXISTING WALL

SCRAPE CLEAN, PRIME, PAINT

DORMER AND WINDOW (FRAME AND

SASHES). REPAIR WOOD AS

REQUIRED. NEW SEALANT AROUND

PERIMETER OF FRAME - PAINT TO

MATCH EXISTING COLOR

Kenosha, WI 53143

B U

IL

D

IN

G

E N

VE

LO

PE

R

ES

TO

R

AT

IO

N

KE

M

PE

R

C

EN

TE

R

KE

N

O

SH

A C

O U

N

TY

ISSUE FOR BID

01/07/2026

InSite Consulting Architects 744 Williamson St. / STE 101 Madison, Wisconsin 53703 608-204-0825 608-531-1533 (fax) info@icsarc.com

A9

CHIMNEY SCOPE

CHIMNEY PHOTO - SOUTH ELEVATION1

A9

REPOINT BASE OF CHIMNEY -

ALL SIDES (BOTTOM 36

COURSES)

CHIMNEY PHOTO - NORTH ELEVATION - ALTERNATE NO. 22

A9

REPOINT NORTH

ELEVATION OF

CHIMNEY (TOP

58 COURSES)

Kenosha, WI 53143

B U

IL

D

IN

G

E N

VE

LO

PE

R

ES

TO

R

AT

IO

N

KE

M

PE

R

C

EN

TE

R

KE

N

O

SH

A C

O U

N

TY

ISSUE FOR BID

01/07/2026

InSite Consulting Architects 744 Williamson St. / STE 101 Madison, Wisconsin 53703 608-204-0825 608-531-1533 (fax) info@icsarc.com

A10

TYPICAL WINDOW

RESTORATION SCOPE

Scale: 3" = 1'-0"

TYPICAL HEAD DETAIL3

A10

REMOVE ALL

PERIMETER SEALANT -

CLEAN AND PREPARE

SURFACES FOR NEW

SEALANT

PROVIDE NEW WHITE SCREEN

FRAME AND FABRIC. SCREEN

FRAME SHALL HAVE HORIZONTAL

STABILIZER BAR WITH 4 SPRING

LOCKED PINS PER SCREEN

BRICK JAMB/RETURNS ONLY

1. REMOVE MORTAR

(CENTER-CUT METHOD ONLY)

TO A DEPTH OF 2.5X THE

WIDTH OF THE JOINT.

2. PREPARE JOINT FOR

REPOINTING.

3. INSTALL NEW MORTAR PER

THE SPECIFICATIONS - MATCH

ADJACENT MORTAR IN ALL

WAYS - INCLUDING COLOR,

FINISH STRENGTH AND

TOOLING.

Scale: 1/2" = 1'-0"

TYPICAL EXTERIOR ELEVATION1

A10

NOTE: ACTUAL EXISTING

CONDITIONS IN THE FIELD MAY

VARY. VERIFY ALL CONDITIONS IN

THE FIELD.

EXISTING CONSTRUCTION MAY

REMAIN - CONFIRM IN FIELD

INSPECT WOOD FRAME/TRIM

IN-SITU. REPLACE ALL DAMAGED

WOOD WITH 1/4 SAWN DOUGLAS

FIR. CONSOLIDATE IF POSSIBLE -

PATCH AND DUTCHMAN. ALL

REPAIRS NOT SPECIFICALLY

NOTED WILL BE BY CHANGE

ORDER. SCRAPE, CLEAN, PRIME

AND PAINT ALL EXTERIOR

SURFACES (FRAME

CONFIGURATION VARIES)

A10

A10

A10

REPAINT EXTERIOR SIDE OF SASH

PROVIDE WINDOW SCREEN

RETAINER CLIP (2 PER SCREEN).

INSTALL 1'-0" FROM TOP OF

SCREEN, BOTH JAMBS

1' -0

RETAINER CLIPS:

USE .4375" WHITE FLUSH RETAINER

CLIP BY "PRIME-LINE".

ANY SUBSTITUTIONS MUST BE

APPROVED BY ARCHITECT

Scale: 3" = 1'-0"

TYPICAL JAMB DETAIL2

A10

AREA OF REPOINT

EXISTING LIMESTONE

SILL (BELOW)

REMOVE ALL PERIMETER

SEALANT - CLEAN AND

PREPARE SURFACES FOR

NEW SEALANT

Scale: 3" = 1'-0"

TYPICAL SILL DETAIL4

A10

NOTE: ACTUAL EXISTING

CONDITIONS IN THE FIELD MAY

VARY. VERIFY ALL CONDITIONS IN

THE FIELD.

EXISTING CONSTRUCTION MAY

REMAIN - CONFIRM IN FIELD

INSPECT WOOD FRAME/TRIM

IN-SITU. REPLACE ALL DAMAGED

WOOD WITH 1/4 SAWN DOUGLAS

FIR. CONSOLIDATE IF POSSIBLE -

PATCH AND DUTCHMAN. ALL

REPAIRS NOT SPECIFICALLY

NOTED WILL BE BY CHANGE

ORDER. SCRAPE, CLEAN, PRIME

AND PAINT ALL EXTERIOR

SURFACES (FRAME

CONFIGURATION VARIES)

REPAINT EXTERIOR SIDE OF SASH

6' -8

" R .O

+/- 2'-11 1/2" R.O.

+/- 3'-2"" R.O.

3'

-5 " R

.O

3' -0

" R .O

+/- 2'-11 1/2" R.O.

Kemper Center 6501 3rd Ave Kenosha, WI 53143

B U

IL

D

IN

G

E N

VE

LO

PE

R

ES

TO

R

AT

IO

N

KE

M

PE

R

C

EN

TE

R

KE

N

O

SH

A C

O U

N

TY

ISSUE FOR BID

01/07/2026

InSite Consulting Architects 744 Williamson St. / STE 101 Madison, Wisconsin 53703 608-204-0825 608-531-1533 (fax) info@icsarc.com

A11

WINDOW REPLACEMENT

TYPES AND SCHEDULE

WINDOW TYPE A1

A11 Scale: 1/2" = 1'-0"

A12

A12

A12

VE

R

IF

Y

IN

F

IE

LD

VERIFY IN FIELD

NO. TYPE INTERIOR FINISH EXTERIOR SASH

FINISH

EXTERIOR FRAME

FINISH SCREEN

W001 C NONE PAINT - MATCH

EXISTING COLOR

PAINT - MATCH

EXISTING COLOR YES

W201 A STAIN - MATCH

EXISTING COLOR

PAINT - MATCH

EXISTING COLOR

PAINT - MATCH

EXISTING COLOR YES

W202 B STAIN - MATCH

EXISTING COLOR

PAINT - MATCH

EXISTING COLOR

PAINT - MATCH

EXISTING COLOR YES

W203 A STAIN - MATCH

EXISTING COLOR

PAINT - MATCH

EXISTING COLOR

PAINT - MATCH

EXISTING COLOR YES

W204 A STAIN - MATCH

EXISTING COLOR

PAINT - MATCH

EXISTING COLOR

PAINT - MATCH

EXISTING COLOR YES

W205 A STAIN - MATCH

EXISTING COLOR

PAINT - MATCH

EXISTING COLOR

PAINT - MATCH

EXISTING COLOR YES

W301 A STAIN - MATCH

EXISTING COLOR

PAINT - MATCH

EXISTING COLOR

PAINT - MATCH

EXISTING COLOR YES

W302 A STAIN - MATCH

EXISTING COLOR

PAINT - MATCH

EXISTING COLOR

PAINT - MATCH

EXISTING COLOR YES

WINDOW REPLACEMENT SCHEDULE

WINDOW TYPE B2

A11 Scale: 1/2" = 1'-0"

VE

R

IF

Y

IN

F

IE

LD

VERIFY IN FIELD

WINDOW TYPE C3

A11 Scale: 1/2" = 1'-0"

VE

R

IF

Y

IN

F

IE

LD

VERIFY IN FIELD

A12

A12 SIM.

A12 SIM.

A12 SIM.

A12 SIM.

A12 SIM.

SIM.

A12

MATCH EXISTING

6501 3rd Ave Kenosha, WI 53143

B U

IL

D

IN

G

E N

VE

LO

PE

R

ES

TO

R

AT

IO

N

KE

M

PE

R

C

EN

TE

R

KE

N

O

SH

A C

O U

N

TY

ISSUE FOR BID

01/07/2026

InSite Consulting Architects 744 Williamson St. / STE 101 Madison, Wisconsin 53703 608-204-0825 608-531-1533 (fax) info@icsarc.com

A12

TYPICAL WINDOW

REPLACEMENT DETAILS

JAMB DETAIL3

A12 Scale: 3" = 1'-0"

HEAD DETAIL1

A12 Scale: 3" = 1'-0"

SILL DETAIL2

A12 Scale: 3" = 1'-0"

CONTINUOUS WOOD BLOCKING

ALONG ENTIRE LENGTH OF OPENING

WATER-RESISTIVE BARRIER - EXTEND

AS SHOWN. PROVIDE SEALANT AT ALL

LAPS AND TERMINATIONS

WOOD REPLACEMENT

WINDOW

CONTINUOUS SEALANT

CONTINUOUS SEALANT

SCREEN

WOOD REPLACEMENT

WINDOW

CONTINUOUS WOOD

BLOCKING BETWEEN HEAD

AND SILL WOOD BLOCKING

WATER-RESISTIVE BARRIER -

EXTEND AS SHOWN. PROVIDE

SEALANT AT ALL LAPS AND

TERMINATIONS

CONTINUOUS SEALANT

WOOD REPLACEMENT

WINDOW

SPRAY FOAM INSULATION (IF

CAVITY IS ACCESSIBLE

DURING REPLACEMENT)

SHIM AS REQUIRED SHIM AS REQUIRED

EXISTING CONSTRUCTION IS

UNKNOWN - VERIFY IN FIELD

JAMB DETAIL @ MULLION4

A12 Scale: 3" = 1'-0"

CONTINUOUS WOOD BLOCKING

BETWEEN HEAD AND SILL WOOD

BLOCKING

WATER-RESISTIVE BARRIER -

EXTEND AS SHOWN. PROVIDE

SEALANT AT ALL LAPS AND

TERMINATIONS

WOOD MULLION PROVIDED

BY WINDOW MANUFACTURER

SHIM AS REQUIRED

MATCH EXISTING

PROVIDE INTERIOR MULLION

COVER. STAIN TO MATCH

EXISTING

PROTECT EXISTING INTERIOR

FINISHES DURING WINDOW

REPLACEMENT

Kenosha, WI 53143

B U

IL

D

IN

G

E N

VE

LO

PE

R

ES

TO

R

AT

IO

N

KE

M

PE

R

C

EN

TE

R

KE

N

O

SH

A C

O U

N

TY

ISSUE FOR BID

01/07/2026

InSite Consulting Architects 744 Williamson St. / STE 101 Madison, Wisconsin 53703 608-204-0825 608-531-1533 (fax) info@icsarc.com

A13

PHOTO OF DOOR D101 - EXTERIOR1

A13

+/-8'-11" R .O

VER

IFY IN

FIELD

+/- 3'-4" R.O.

VERIFY IN FIELD

MATCH

EXISTING

TRANSOM IN

ALL WAYS

PROVIDE

SEALANT

AROUND

PERIMETER

PHOTO OF DOOR D101 - INTERIOR2

A13

PHOTO OF DOOR D101 - INTERIOR TRANSOM3

A13

PHOTO OF DOOR D101 - INTERIOR JAMB4

A13

+/-7'-11"

VER

IFY IN

FIELD

CL

PRESERVE EXISTING DOOR

CASING - REMOVE AND

REINSTALL AS REQUIRED

REPLICATE ALL EXISTING

MOLDING PROFILES

+/- 7"VERIFY INFIELD

DOOR REPLACEMENT

SCOPE

Kenosha, WI 53143

B U

IL

D

IN

G

E N

VE

LO

PE

R

ES

TO

R

AT

IO

N

KE

M

PE

R

C

EN

TE

R

KE

N

O

SH

A C

O U

N

TY

ISSUE FOR BID

01/07/2026

InSite Consulting Architects 744 Williamson St. / STE 101 Madison, Wisconsin 53703 608-204-0825 608-531-1533 (fax) info@icsarc.com

DOOR REPLACEMENT

SCOPE

A14

PHOTO OF DOOR D102 - EXTERIOR1

A14

+/- 3'-3" R.O.

VERIFY IN FIELD

+/-7'-3" R .O

VER

IFY IN

FIELD

PROVIDE

SEALANT

AROUND

PERIMETER

PHOTO OF DOOR D102 - JAMB1a A14

PHOTO OF DOOR D102 - INTERIOR1b A14

PRESERVE EXISTING

WOOD TRIM. REMOVE

AND REINSTALL AS

REQUIRED

PHOTO OF DOOR D104 - EXTERIOR3

A14

PHOTO OF DOOR D103 - EXTERIOR2

A14

+/- 3'-9" R.O.

VERIFY IN FIELD

+/-6'-10" R .O

VER

IFY IN

FIELD

+/- 3'-3 1/2" R.O.

VERIFY IN FIELD

+/-7'-2" R .O

VER

IFY IN

FIELD

PROVIDE

SEALANT

AROUND

PERIMETER

PROVIDE

SEALANT

AROUND

PERIMETER

Kenosha, WI 53143

B U

IL

D

IN

G

E N

VE

LO

PE

R

ES

TO

R

AT

IO

N

KE

M

PE

R

C

EN

TE

R

KE

N

O

SH

A C

O U

N

TY

ISSUE FOR BID

01/07/2026

InSite Consulting Architects 744 Williamson St. / STE 101 Madison, Wisconsin 53703 608-204-0825 608-531-1533 (fax) info@icsarc.com

DOOR SCHEDULE

A15

DOOR AND HARDWARE SCHEDULE

DOOR

NUMBER

DOOR FRAME

REMARKS

LEAF SIZE

MATERIAL GLAZING EXTERIOR FINISH INTERIOR FINISH MATERIAL EXTERIOR FINISH INTERIOR FINISH HARDWAREWIDTH HEIGHT

D101 3'-0" 7'-0" WOOD

1/4"

INSULATED,

TEMPERED

PAINT - MATCH

EXISTING COLOR

STAIN - MATCH

EXISTING COLOR WOOD PAINT - MATCH

EXISTING COLOR

STAIN - MATCH

EXISTING COLOR

SEE SPECS

AND

REMARKS

1, 2

D102 3'-0" 7'-0" WOOD - PAINT - MATCH

EXISTING COLOR

STAIN - MATCH

EXISTING COLOR WOOD PAINT - MATCH

EXISTING COLOR

STAIN - MATCH

EXISTING COLOR

SEE SPECS

AND

REMARKS

1, 2

D103 3'-3" 6'-7" WOOD - PAINT - MATCH

EXISTING COLOR

PAINT - MATCH

EXISTING COLOR WOOD PAINT - MATCH

EXISTING COLOR

PAINT - MATCH

EXISTING COLOR

SEE SPECS

AND

REMARKS

1, 2

D104 3'-0" 7'-0" WOOD - PAINT - MATCH

EXISTING COLOR

STAIN - MATCH

EXISTING COLOR WOOD PAINT - MATCH

EXISTING COLOR

STAIN - MATCH

EXISTING COLOR

SEE SPECS

AND

REMARKS

1, 2

DOOR AND HARDWARE SCHEDULE REMARK NOTES

1. IT IS THE INTENT THAT THE NEW DOOR DESIGN MATCH EXISTING IN ALL WAYS

2. SALVAGE AND REUSE EXISTING LOCKSETS, CYLINDERS, PULL HANDLES, STRIKE PLATES, AND CLOSERS

Kenosha, WI 53143

B U

IL

D

IN

G

E N

VE

LO

PE

R

ES

TO

R

AT

IO

N

KE

M

PE

R

C

EN

TE

R

KE

N

O

SH

A C

O U

N

TY

ISSUE FOR BID

01/07/2026

InSite Consulting Architects 744 Williamson St. / STE 101 Madison, Wisconsin 53703 608-204-0825 608-531-1533 (fax) info@icsarc.com

CAP FLASHING DETAIL

A16

Scale: 6" = 1'-0"

CAP FLASHING DETAIL - TYPICAL1

A16

COPPER FLASHING SET IN A BED OF

SEALANT - CONFIGURE AS SHOWN

SELF-ADHERING MEMBRANE STRIP-IN

FLASHING - EXTEND AS SHOWN

CONTINUOUS LAP SEALANT

TUBE WEEPS @ EVERY HEAD

JOINT

DRILL HOLE IN NEW WEEP TUBE

TO ACCOMMODATE CROSS

DRAINAGE

3/8" DIAMETER X 4" LONG STAINLESS

STEEL PIN - MIN. (2) PER STONE.

FILL WITH SEALANT - TOP AND

BOTTOM

SEALANT @ PIN ANCHOR

SELF-ADHERING MEMBRANE FLASHING,

CONFIGURE AS SHOWN; CLEAN AND

PRIME ALL SURFACES PRIOR TO

INSTALLATION. NEW CONTINUOUS

SEALANT AT ALL LAPS AND BRAKES IN

MATERIAL

REUSE EXISTING COPING STONE

MATCH EXISTING PROFILE

MORTAR

CONFIRM EXISTING COLLAR JOINTS

ARE FULL AND FILL WITH MORTAR

AS REQUIRED

CAVITY

SPACE

LEAD CAP FLASHING AT ALL SKY

JOINTS - EXTEND AS SHOWN

BACKER ROD AND SEALANT

EXPANSION ANCHOR

@ 24" O.C.

CONTINUOUS SPRING-LOCKED

STAINLESS STEEL COUNTERFLASHING

RECEIVER SET IN A BED OF SEALANT

SEAL EXISTING ROOF

MEMBRANE TERMINATION AS

REQUIRED TO MAKE

WATERTIGHT

STAINLESS STEEL

COUNTERFLASHING - FASTEN @

12" O.C.

SET PIN MINIMUM 1" FROM TOP OF

STONE

PACK FULL MORTAR

VERIFY IN FIELD

GRIND EXISTING MORTAR TO

SOUND MATERIAL - 2-1/2" TIMES

THE JOINT WIDTH/HEIGHT

MAXIMUM

EXISTING OR REPLACEMENT

MASONRY

NOTE: REPOINT USING CENTER-CUT METHOD. HOLD

BACK FACE OF MORTAR AT REPLACEMENT BRICK -

REPOINT REMAINDER OF MORTAR JOINT FOR

CONSISTENT APPEARANCE

STRIKE MORTAR TO MATCH

EXISTING IN ALL WAYS

Kemper Center 6501 3rd Ave Kenosha, WI 53143

B U

IL

D

IN

G

E N

VE

LO

PE

R

ES

TO

R

AT

IO

N

KE

M

PE

R

C

EN

TE

R

KE

N

O

SH

A C

O U

N

TY

ISSUE FOR BID

01/07/2026

InSite Consulting Architects 744 Williamson St. / STE 101 Madison, Wisconsin 53703 608-204-0825 608-531-1533 (fax) info@icsarc.com

TYPICAL MASONRY DETAILS

A17

Scale: FULL SIZE

TYPICAL REPOINTING DETAIL1

A17

LEAD CAME

BACKER ROD AND

SEALANT

D

EP

TH

.5 x

JO

IN

T

W

ID

TH

Scale: FULL SIZE

TYPICAL LEAD FLASHING DETAIL2

A17 Scale: 3" = 1'-0"

TYPICAL BRICK INFILL DETAIL3

A17

CONTINUE ALL HEADER

COURSES OF EXISTING

WALL

2"

VERIFY EXISTING

CONSTRUCTION

EXISTING LIMESTONE

SILL

MATCH TOOLING OF

EXISTING WALL

PROVIDE BRICK - MATCH

EXISTING

Sheets and Views
Kemper Center 2026-TS
Kemper Center 2026-A1
Kemper Center 2026-A2
Kemper Center 2026-A3
Kemper Center 2026-A4
Kemper Center 2026-A5
Kemper Center 2026-A6
Kemper Center 2026-A7
Kemper Center 2026-A8
Kemper Center 2026-A9
Kemper Center 2026-A10
Kemper Center 2026-A11
Kemper Center 2026-A12
Kemper Center 2026-A13
Kemper Center 2026-A14
Kemper Center 2026-A15
Kemper Center 2026-A16
Kemper Center 2026-A17

File details come from the government source that posted it. Updated .