26-8627_-_Exhibit_M_-_PLANS_and_DRAWINGS_BID_SET.pdf
PDF 36 MB Posted
- Solicitation number
- 26-8627
- Issued by
- Collier County, Florida
About this file
This is a comprehensive bid set of plans and drawings for Collier County's Northeast Water Reclamation Facility Deep Injection Well Equipping and Conveyance project (Bid No. 26-8627), prepared by Carollo Engineers, Inc. and Johnson Engineering, LLC. The project encompasses the design and construction of two deep injection wells, one dual-zone monitoring well, approximately 3,800 linear feet of 36-inch and 24-inch diameter high-density polyethylene (HDPE) piping for conveyance, control systems, and associated instrumentation. The bid set includes detailed site plans, civil engineering drawings with plan and profile alignments, structural details for well pads and monitoring facilities, mechanical specifications for pumps and pressure equipment, comprehensive electrical schematics with control panel designs, and instrumentation diagrams with process and instrumentation drawings (P&IDs). A non-mandatory pre-bid meeting is scheduled for January 13, 2026, at 2:00 p.m., with sealed bids due electronically by February 12, 2026, at 3:00 p.m. local time. The contractor must achieve substantial completion within 425 calendar days from the Notice to Proceed, with work limited to 7:00 a.m. to 7:00 p.m., Monday through Friday, unless otherwise specified.
The project has an anticipated budget of $7,184,000 with a $600,000 Owner's Allowance for unforeseen conditions and change orders. Bidders must submit a certified bid bond equal to five percent of the total bid amount and provide Payment and Performance Bonds covering 100 percent of the contract value through a Florida-licensed surety. Liquidated damages of $2,535.53 per calendar day apply for failure to achieve substantial completion on schedule. Prospective bidders must demonstrate qualification through five project references completed within the last five years, current Florida contractor's licenses, E-Verify enrollment, and appropriate insurance certifications. The solicitation does not identify incumbent vendors or specific set-asides for disadvantaged enterprises. Plans and drawings were digitally signed and sealed by multiple professional engineers and are dated November 2025, indicating final approval for bid set distribution.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET DRAWING
NUMBER TITLE
GENERAL
1 00G01 COVER SHEET
2 00G02 NOTES AND DRAWING SYMBOLOGY
3 00G03 SYMBOLS 1
4 00G04 SYMBOLS 2
5 00G05 OVERALL SITE PLAN
6 00G06 ENLARGED SITE PLAN
7 00G07 INJECTION WELLS AND MONITORING WELL PROCESS FLOW DIAGRAM
CIVIL
8 00C01 NOTES AND LEGENDS
9 00C02 KEY MAP
10 00C03 PLAN & PROFILE ALIGNMENT A 0+00_TO_4+00
11 00C04 PLAN & PROFILE ALIGNMENT B 2+50_TO_7+00
12 00C05 PLAN & PROFILE ALIGNMENT B 7+00_TO_12+00
13 00C06 PLAN & PROFILE ALIGNMENT C 11+00_TO_16+50
14 00C07 PLAN & PROFILE ALIGNMENT D 16+00_TO_21+50
15 00C08 PLAN & PROFILE ALIGNMENT D 21+50_TO_27+00
16 00C09 PLAN & PROFILE ALIGNMENT D 27+00_TO_32+50
17 00C10 PLAN & PROFILE ALIGNMENT D 32+50_TO_38+00
18 00C11 PLAN & PROFILE WELL SITE & ALIGNMENT E
19 00C12 DIIW METER ASSEMBLY DETAILS & CROSS SECTION
STRUCTURAL
20 S01 GENERAL STRUCTURAL NOTES
21 S02 DEEP INJECTION WELL PLAN AND SECTION
22 S03 MONITORING WELL PLAN AND SECTION
PROCESS MECHANICAL
23 PM01 DEEP INJECTION WELL - PLAN
24 PM02 INJECTION WELL WELLHEAD SECTIONS
25 PM03 MONITORING WELL SURFACE FEATURES PLAN AND SECTIONS
26 PM04 INJECTION AND MONITORING WELL DETAILS
ELECTRICAL
27 00GE01 LEGEND
28 00GE02 NOTES
29 00E01 SITE PLAN
SHEET DRAWING
NUMBER TITLE
30 00E02 RISER DIAGRAMS SHEET NO. 1
31 00E03 RISER DIAGRAMS SHEET NO. 2
32 00E04 SCHEDULES SHEET NO. 1
33 00E05 SCHEDULES SHEET NO. 2
34 00E06 SCHEMATICS SHEET NO. 1
35 00E07 DEEP INJECTION WELSS LAYOUT
36 00E08 MONITORING WELL LAYOUT
37 00E09 NESA WWTP ELECTRICAL ROOM
38 00E10 DETAILS SHEET NO. 1
39 00E11 DETAILS SHEET NO. 2
INSTRUMENTATION
40 00GN01 SYMBOLS AND ABBREVIATIONS 1
41 00GN02 SYMBOLS AND ABBREVIATIONS 2
42 00GN03 SYMBOLS AND ABBREVIATIONS 3
43 00GN04 SYMBOLS AND ABBREVIATIONS 4
44 00GN05 SCHEMATIC SYMBOLS
45 00N01 INJECTION WELLS P&ID
46 00N02 MONITORING WELL P&ID
47 00N03 PLC ENCLOSURE DETAIL
48 00N04 PLC CONTROL WIRING DETAIL
49 00N05 DIW NETWORK PANEL ELEVATION
50 00N06 DIW NETWORK CABINET POWER WIRING DETAIL
51 00N07 DIW SUMP PUMPS CONTROL SCHEMATIC
52 00N08 MONITORING WELL PUMPS CONTROL SCHEMATIC
53 00N09 SINGLE PHASE SUMP PUMP CONTROL SCHEMATIC
54 03N01 NETWORK BLOCK DIAGRAM
55 10N01 IQ DEEP INJECTION WELL METERING STATION P&ID
TYPICAL DETAILS
56 TA01 ARCHITECTURAL 1
57 TS01 STRUCTURAL 1
58 TS02 STRUCTURAL 2
59 TS03 STRUCTURAL 3
60 TS04 STRUCTURAL 4
61 TM01 MECHANICAL 1
62 TN01 INSTRUMENTATION 1
PROJECT NO.
LA
ST
S
AV
ED
B
Y:
FILE NAME: 7126I1000G01.dwg
Al ai co
7126I10
DRAWING NO.
SHEET NO.
OF 621
00G01301 North Cattlemen Road, Suite 302 Sarasota, FL 34232
Phone: 941-371-9832 CA No. 00008571
LOCATION MAPVICINITY MAP
10 11 12 135 6 7 8 91 2 3 4
A
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G
/6
/2
3:
:0
PM
Pl ot
D at e:
CONTRACT DOCUMENTS
NORTHEAST WATER RECLAMATION
FACILITY/WATER TREATMENT PLANT
DIW CONVEYANCE
COLLIER COUNTY PROJECT #: 70194 .2
PROJECT LOCATION
COLLIER COUNTY
NOVEMBER 2025
SCALE: NTS SCALE: NTS
PROJECT LOCATION
VOLUME 2 OF 2
No 52648JO
SEPH J . HANLO
NNo 58434
JO
EL D . SMASON
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY
JOEL D. SMASON ON THE DATE ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE SIGNATURE
BE VERIFIED ON ANY ELECTRONIC COPIES.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY
MATTHEW S. LOVE ON THE DATE ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE SIGNATURE
BE VERIFIED ON ANY ELECTRONIC COPIES.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY
JOSEPH J. HANLON ON THE DATE ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE SIGNATURE
BE VERIFIED ON ANY ELECTRONIC COPIES.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY
ALEKSANDAR D. STOJANOVIC ON THE DATE ADJACENT TO
THE SEAL.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE SIGNATURE
BE VERIFIED ON ANY ELECTRONIC COPIES.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY
JARED ROY BROWN ON THE DATE ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE SIGNATURE
BE VERIFIED ON ANY ELECTRONIC COPIES.
THE BOARD OF COLLIER COUNTY COMMISSIONERS
DISTRICT 1 - RICK LOCASTRO
DISTRICT 2 - CHRIS HALL
DISTRICT 3 - BURT L. SAUNDERS
DISTRICT 4 - DAN KOWAL
DISTRICT 5 - WILLIAM L. MCDANIEL, JR.
COUNTY MANAGER
AMY PATTERSON
A ##X##
VIEW
REVISION DELTA
SCALE
FENCE
GUARDRAIL
CENTER LINE
REMOVE AND/OR ABANDON
GATE
EXISTINGNEW
DETAIL REFERENCES HATCH PATTERNS
VIEW
DRAWING CUT ORIGINATION
TYPICAL DETAIL #
TYP
FILE:
SCALE:
FILE:
100'0 50' 200'
SECTION CUT
TYPICAL DETAIL
REFERENCE
(EXIST)
EXTERIOR ELEVATION
VIEWS
PHOTO LOCATION
KEY NOTE
EQUIPMENT/DEVICE
TAG AND NUMBER
AGRID BUBBLE
PIPE TAG
BREAK LINE
TR
UE
N O
R
TH
PL
AN
T
NO
RT
H
30°
NORTH ARROW/PLANT NORTH
UNDERGROUND/
OVERHEAD
WARNING
(STATE/REGION
SPECIFIC)
SYMBOLS
NOTES
MATCH LINE
HIDDEN LINE
MATCH LINE SEE DWG ##X##
VIEW
ELEVATION TOC XXXX.XX
EXISTING ELEVATION
PIPE BREAK
PLAN VIEW
PIPE BREAK
CROSS SECTION
CONSTRUCTION
FUTURE CONSTRUCTION
PIPE CONTINUATION
(SINGLE LINE)
BRACKET
EQUIPMENT
EX-EQUIP = EXISTING EQUIPMENT
EF-EQUIP = FUTURE EQUIPMENT
SIZE FLOW STREAM
EX-SIZE FLOW STREAM = EXISTING
EF-SIZE FLOW STREAM = FUTURE
PLAN/TITLE
SECTION OR DETAIL
TITLE W/ REFERENCE
ALPHA = SECTION
NUMERIC = DETAIL
DETAIL CALL-OUT
(ENLARGED)
ARROW INDICATES
POINT OF VIEW
- = SHOWN ON SAME DRAWING
##X## = SEE INDICATED DRAWING
DRAWING REFERENCE ##X##
DISCIPLINE DESIGNATOR
SEE INDICATED
DRAWING
SHEETS IN
DETAIL
TYPICAL DETAIL NUMBER
TYPICAL DETAIL TITLE
AREA DESIGNATOR
(WHEN APPLICABLE)
CONSECUTIVE
SHEET NUMBER
DATE CREATED
(REVISED)
PLAN NOT REFERENCED
LINE WORK
MODIFICATION NOTE
S = STANDARD
J = JOB SPECIFIC
R = REVISED
N = NOTE TO TYPICAL DETAIL USER
T.O.W. XXXX.X±
PIPE SIZE FLOW STREAM
XXX-XX-XXXX
X" XXX
##X##
SHT # OF #MOD
LINE 2
LINE 1
LINE 3
VER DATE
TYP
SECTION/DETAIL TITLEC/1
##X##
FILE
SCALE
C
A FILE
PLAN TITLE
1. FOLLOWING NOTES ARE GENERAL AND APPLY TO ALL SHEETS OF THESE CONTRACT DOCUMENTS AS IF
THEY WERE WRITTEN IN THEIR ENTIRETY ON EACH SHEET.
2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS BEFORE STARTING WORK AND SHALL IMMEDIATELY NOTIFY THE ENGINEER OF ANY DISCREPANCIES. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL EXISTING CONDITIONS INCLUDING LOCATION AND DIMENSIONS OF ALL EXISTING CONSTRUCTION AND UTILITIES. CONTRACTOR SHALL NOTIFY ENGINEER IF THERE IS A CONFLICT BETWEEN THE CONTRACT
DOCUMENTS AND EXISTING CONSTRUCTION BEFORE PROCEEDING WITH WORK.
PRIOR TO EXCAVATION FOR NEW STRUCTURES, ELECTRICAL CONDUIT, FABRICATION OF NEW PIPING AND/OR OTHER PROPOSED UTILITIES, CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION OF ALL EXISTING PIPING AND UTILITIES IN THE CONSTRUCTION AREA. THE CONTRACTOR SHALL TEMPORARILY RELOCATE CONFLICTING EXISTING UTILITIES AT TIE-IN/CONNECTION LOCATIONS AND REINSTALL THEM AS REQUIRED TO ELIMINATE THE CONFLICT AT NO ADDITIONAL COST TO THE
OWNER.
CONTRACTOR SHALL VERIFY LOCATION OF ALL ARCHITECTURAL, MECHANICAL, AND ELECTRICAL ITEMS
BEFORE PLACING ANY STRUCTURAL STEEL OR CONCRETE. ALSO, STRUCTURAL DIMENSIONS AND
OPENINGS CONTROLLED BY ARCHITECTURAL, MECHANICAL, OR ELECTRICAL EQUIPMENT SHALL BE
VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION.
3. UNLESS DETAILED, SPECIFIED, OR OTHERWISE INDICATED ON THE DRAWINGS, CONSTRUCTION SHALL BE AS INDICATED IN THE APPLICABLE TYPICAL DETAILS AND GENERAL NOTES. TYPICAL DETAILS SHALL APPLY
EVEN THOUGH NOT REFERENCED AT SPECIFIC LOCATIONS ON DRAWINGS.
4. CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CONSTRUCTION STORM WATER DISCHARGE
REGULATORY REQUIREMENTS.
5. CONTRACTOR TO REFER TO COLLIER COUNTY DESIGN CRITERIA FOR MINIMUM DEPTH OF COVER. PIPES SHALL BE ROUTED AS SHOWN UNLESS MINOR REVISIONS ARE NECESSARY TO MISS EXISTING PIPES, STRUCTURES, ETC. CONTRACTOR SHALL BE RESPONSIBLE FOR FURNISHING ALL FITTINGS AND ADAPTERS REQUIRED TO MAKE THE ROUTING CHANGES AT NO ADDITIONAL COST TO THE OWNER. CONTRACTOR SHALL INCLUDE COST
FOR THIS IN THE BID.
6. EXISTING FACILITY AND UTILITY INFORMATION SHOWN ON THE DRAWINGS WAS OBTAINED FROM AVAILABLE RECORDS OR ELECTRONIC FILES. NEITHER THE OWNER NOR ENGINEER ASSUMES ANY RESPONSIBILITY FOR FACILITIES AND UTILITIES NOT SHOWN OR NOT IN THE LOCATION SHOWN.
7. THE CONTRACTOR SHALL TAKE ALL PRECAUTIONARY MEASURES NECESSARY TO PROTECT FROM DAMAGE EXISTING FACILITIES AND UTILITIES SHOWN OR NOT SHOWN THAT ARE TO REMAIN IN PLACE.
ALL FACILITIES DAMAGED BY THE CONTRACTOR'S OPERATIONS SHALL BE EXPEDITIOUSLY REPAIRED
OR RECONSTRUCTED TO THE ORIGINAL OR BETTER CONDITION AT THE CONTRACTOR'S EXPENSE
WITHOUT ADDITIONAL COMPENSATION.
8. CONTRACTOR SHALL MAKE CONNECTIONS TO EXISTING PIPE, EQUIPMENT, ETC. AS REQUIRED AND SHALL PROVIDE ALL FITTINGS, ADAPTERS, AND APPURTENANCES REQUIRED TO MAKE THE CONNECTIONS.
PROVIDE ALL SUPPORTS REQUIRED FOR A RIGIDLY SUPPORTED COMPLETE AND WORKING SYSTEM.
9. ADJUST ALL VALVE BOXES, VAULTS, PULL BOXES, AND MANHOLES TO FINISHED GRADE UNLESS OTHER- WISE SHOWN OR DIRECTED. MANHOLES IN OPEN FIELDS SHALL BE SET TWELVE INCHES ABOVE FINISHED
GRADE AND VAULTS SHALL BE SIX INCHES ABOVE FINISHED GRADE.
10. THE CONTRACTOR SHALL CONTACT THE PROPER UTILITY REPRESENTATIVE AS FOLLOWS FOR
QUESTIONS OR COORDINATION OF CONSTRUCTION RELATED TO EXISTING UTILITIES.
11. CONTRACTOR SHALL VERIFY THAT PIPING SHOWN TO BE ABANDONED OR AS ABANDONED PREVIOUSLY IS NO LONGER IN SERVICE. LINES IN SERVICE SHALL BE MAINTAINED UNTIL NO LONGER REQUIRED BY
THE PLANT.
12. ALL EXISTING PIPES THAT ARE TO BE ABANDONED IN PLACE OR REMOVED MAY NOT BE SHOWN.
WHERE PIPING IS TO BE ABANDONED AND MUST REMAIN IN SERVICE UNTIL COMPLETION OF OTHER PHASES OF WORK, AND IT CONFLICTS WITH NEW PIPING, TEMPORARILY RELOCATE PIPING AS REQUIRED
TO MAINTAIN SERVICE BY THE PLANT.
13. CONTRACTOR SHALL REROUTE THE EXISTING PIPING IF REQUIRED TO MISS THE PROPOSED STRUCTURES.
THE EXISTING PIPE SHALL REMAIN IN SERVICE UNTIL NEW PIPING IS READY TO BE PLACED INTO SERVICE.
PLAN SHALL BE SUBMITTED AND APPROVED 30 DAYS MINIMUM PRIOR TO COMMENCEMENT OF WORK.
14. THE CONTRACTOR SHALL TAKE SPECIAL PRECAUTIONS IN THE VICINITY OF ANY OVERHEAD ELECTRIC LINES. CONTRACTOR SHALL ABIDE BY THE NATIONAL ELECTRIC CODE AND ANY REQUIREMENT BY THE
OWNER OF THE ELECTRIC LINES.
15. PROVIDE ALL SHEETING/SHORING REQUIRED TO PROTECT EXISTING STRUCTURES, PIPES AND FACILITIES.
16. MECHANICAL AND ELECTRICAL EQUIPMENT SUPPORTS, ANCHORAGES, OPENINGS, RECESSES, AND REVEALS NOT SHOWN ON THE STRUCTURAL DRAWINGS, THAT ARE REQUIRED BY OTHER CONTRACT
DRAWINGS, SHALL BE PROVIDED PRIOR TO CASTING CONCRETE.
17. ELEVATIONS SHOWN HEREON ARE BASED ON NORTH AMERICAN VERTICAL DATUM 1988 (NAVD '88).
CONVERSION FACTOR TO NATIONAL GEODETIC VERTICAL DATUM 1929 (NGVD '29) IS (+) 1.257
RUBBER
TREAD PLATE
LANDSCAPING
GRATING
STEEL
ALUMINUM
BRONZE, BRASS,
OR COPPER
BRICK OR BLOCK
AGGREGATE BASE
COURSE (ABC)
BEDROCK
CAST IRON OR
FIBERGLASS
CLSM
CONCRETE
(ALL CLASSES)
DRAIN ROCK
STRUCTURAL FILL
OR BACKFILL
WOOD
SPAN
ASPHALT PAVING
GRAVEL
EXISTING/
UNDISTURBED SOIL
Know what's below.
Call before you dig.
SAND OR GROUT
KEY TAG X
DATEREV BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
7126I.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OFNOVEMBER 2025
COLLIER COUNTY
NORTHEAST WRF/WTP -DIW CONVEYANCE
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
301 North Cattlemen Road, Suite 302 Sarasota, FL 34232
Phone: 941-371-9832 CA No. 00008571 62
10/25 RC BID SET
THIS DOCUMENT HAS BEEN DIGITALLY SIGNED
AND SEALED BY MATTHEW S. LOVE ON THE DATE
ADJACENT TO THE SEAL ON THE COVER SHEET.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE BE VERIFIED ON ANY ELECTRONIC
COPIES.
PROJECT NO.
LA
ST
S
AV
ED
B
Y:
FILE NAME:
MAB
AMR
LDM
00G02
GENERAL
NOTES AND DRAWING SYMBOLOGY
7126I1000G02.dwg ar ic ar do
7126I10
/6
/2
3:
:3
PM
Pl ot
D at e:
PIPING SYMBOLS MECHANICAL SYMBOLS
VV
K
SILENT CHECK VALVE
ECCENTRIC PLUG VALVE
MUD VALVE (PLAN VIEW)
ELBOW, 11.25 DEGREE
ELBOW, 22.5 DEGREE
SWING CHECK VALVE
FLEXIBLE COUPLING ADAPTER
DISMANTLING JOINT
WAFER CHECK VALVE
GLOBE VALVE
ANCHOR
CAP
CROSS
LATERAL
TEE
UNION
FLANGED COUPLING ADAPTER
GROOVED END ADAPTER
FLANGED COUPLING ADAPTER
FLEXIBLE COUPLING
EXPANSION COMPENSATOR
ELBOW, 90 DEGREE
LUBRICATED PLUG
BALL CHECK VALVE
KNIFE GATE VALVE
MIXING VALVE
DUAL CHECK VALVE
DIAPHRAGM VALVE
FLANGE
ELBOW, 45 DEGREE
EXP JOINT
PINCH VALVE
PLUG VALVE
(RUBBER GASKET)
FLANGED JOINT
ADAPTER SIDE
THRUST TIES
WITH THRUST TIES
WELDED JOINT
CONTROL VALVE
GATE VALVE
BALL VALVE
CHARACTERIZED BALL
BUTTERFLY VALVE
TEE DOWN
METAL BELLOWS EXP JOINT
FLEXIBLE COUPLING WITH
ELASTOMER BELLOWS
HUB & SPIGOT JOINT
GROOVED END JOINT
CONCENTRIC REDUCER
ELBOW DOWN
ELBOW UP
TEE UP
LATERAL DOWN
LATERAL UP
VALVE
(RESTRAINED)
PUSH-ON JOINT
3-WAY GLOBE TYPE
NEEDLE VALVE
CHECK BACKFLOW
PREVENTER
M
S
X
M
PUMP: ROTARY
PUMP: METERING
CAVITY
PUMP: CENTRIFUGAL
PUMP: PLUNGER
VENTURI TUBE
STRAINER: WYE TYPE
STRAINER: WYE TYPE
WITH BLOWOFF
WEIR
SLUICE GATE
PUMP: DIAPHRAGM
VALVE: TELESCOPING
VALVE: PLUG ECCENTRIC
VALVE: SWING CHECK
VALVE: AIR RELIEF
VALVE: ANGLE
PRESSURE-REDUCING REGULATOR
PULSATION DAMPENER
PRIMARY FLOW ELEMENT:
PUMP: RECIPROCATING
PUMP: PROGRESSIVE
X = U - ULTRASONIC
X = TH - THERMAL
X = R - ROTAMETER
X = M - MAGNETIC
X = C - CORIOLIS
PRIMARY FLOW ELEMENT:
PUMP: SUBMERSIBLE
PUMP: SCREW
FLUME
PRIMARY FLOW ELEMENT:
ORIFICE PLATE
X = PT - PITOT TUBE
ROTARY CHEMICAL
RUPTURE DISK
SLIDE GATE
SAMPLE PORT
SIGHT GLASS
FEEDER
PRIMARY FLOW ELEMENT:
X = T - TURBINE
X = P - PROPELLER
PRIMARY FLOW ELEMENT:
X = D - DENSITY
VALVE: CONE
VALVE: GATE
FLOW SWITCH
FIRE HYDRANT
RADAR
PRIMARY LEVEL ELEMENT:
THERMOMETER
W/ EXTERNAL PRESSURE TAP
REGULATOR W/EXTERNAL
BACKPRESSURE REGULATOR
VALVE: THREE WAY
BACKPRESSURE REGULATOR
PUMP: PERISTALTIC TUBE METERING
VALVE: THREE WAY
VALVE: THREE WAY
MOTOR OPERATED
SELF-CONTAINED
AIR OPERATED
SOLENOID OPERATED
VALVE: BUTTERFLY
VALVE: BALL CHECK
VALVE: BALL
VALVE: PLUG CONCENTRIC
VALVE: PRESSURE RELIEF
VALVE: VACUUM
PRESSURE TAP
PRESSURE-REDUCING
PRESSURE-REDUCING
VALVE: PINCH
VALVE: NEEDLE
REGULATOR: SELF-CONTAINED
VALVE: FLAPPER CHECK
VALVE: DIAPHRAGM
VALVE: FOUR WAY
VALVE: GLOBE
VALVE: HOSE
DIFFUSER
AIR VENT
OR FLUSHING
RECIPROCATING
DRAIN
BLOWER
QUICK DISCONNECT
PRIMARY LEVEL ELEMENT:
HIGH PRESSURE AIR
BATCHMETER
AIR OR CHEMICAL
COMPRESSOR:
ELECTRIC MOTOR
EXPANSION JOINT,
EQUIPMENT DRAIN
PUMP: VERTICAL LIFT
PIPE REDUCER: CONCENTRIC
FLEXIBLE VIBRATION
COMPRESSOR/TURBINE
CALIBRATION COLUMN
DIAPHRAGM SEAL
JOINT
EJECTOR OR EDUCTOR
FLAME ARRESTER
FLOOR DRAIN
FLAME ARRESTER WITH
PRESSURE
THERMALLY OPERATED VALVE
FAN: EXHAUST/SUPPLY
FILTER
WEIR
FLOAT SWITCH
ULTRASONIC
PRIMARY LEVEL ELEMENT:
PRIMARY LEVEL ELEMENT:
OIL OR MOISTURE TRAP
GAUGE: PRESSURE
GAUGE: DIFFERENTIAL
MIXER
PRIMARY LEVEL ELEMENT:
BUBBLER
BASKET STRAINER
PRIMARY LEVEL ELEMENT:
ELECTRODE
PRIMARY LEVEL ELEMENT:
FLUID
INVERTED COLUMN
DESCRIPTION SINGLE LINE DESCRIPTIONSINGLE LINE DESCRIPTION SINGLE LINEDOUBLE LINE SINGLE LINE DESCRIPTION DESCRIPTIONSINGLE LINEDOUBLE LINE
IDENTIFICATION SYMBOLS
CONTINUATION TO DWG NO.
CONTINUATION FROM DWG NO.UNIQUE IDENTIFIER
CHEMICAL INJECTION POINT
CONTINUATION TAG
PIPE DESIGNATOR
EQUIPMENT / VALVE TAG
PIPE SIZE FLOW STREAM
PIPE MATERIAL CHANGE
XXX-XX-XXXX
X" XXX
C
BA
DWG NO.
CHEMICAL
ECCENTRIC REDUCER
(FOT. FOB)
PIPE REDUCER: ECCENTRIC
(FOT, FOB)
PROJECT NO.
LA
ST
S
AV
ED
B
Y:
FILE NAME:
MAB
AMR
LDM
00G03
GENERAL
SYMBOLS 1
7126I1000G03.dwg ar ic ar do
7126I10
/6
/2
3:
:0
PM
Pl ot
D at e:
DATEREV BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
7126I.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OFNOVEMBER 2025
COLLIER COUNTY
NORTHEAST WRF/WTP -DIW CONVEYANCE
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
301 North Cattlemen Road, Suite 302 Sarasota, FL 34232
Phone: 941-371-9832
AND SEALED BY MATTHEW S. LOVE ON THE DATE
ADJACENT TO THE SEAL ON THE COVER SHEET.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE BE VERIFIED ON ANY ELECTRONIC
COPIES.
B
C
D
E
F
G
H
I
J L
M
N
O
P
R
S
T
U
V
W
ABBREVIATIONS
AGGREGATED BASE
AGGREGATED BASE COURSE
ASPHALTIC CONCRETE
APPROXIMATE
AIR RELEASE VALVE
AMERICAN SOCIETY OF TESTING AND
MATERIALS
BEGIN CURVE
BLIND FLANGE
BACK FLOW PREVENTER
BUTTERFLY VALVE
BUILDING
BEGINNING OF ALIGNMENT
BACK OF CURB
BEGINNING OF PIPE
BALL VALVE
BEGINNING OF VERTICAL CURVE
BYPASS
CABLE TV
CATCH BASIN
CONCRETE CURB
CUBIC FOOT PER MINUTE
CAST IRON
CENTERLINE
CURED IN PLACE PIPE
CLEAR / CLEARANCE
CEMENT MORTAR LINED
CEMENT MORTAR LINED AND COATED
CEMENT MORTAR LINED STEEL PIPE
CORRUGATED METAL PIPE
CONTROL LOW STRENGTH MATERIAL
CONCRETE
CONTROL POINT
COUPLING
CLEANOUT
CONCRETE
COORDINATE
CORRUGATED STEEL PIPE
CENTER
CUBIC
CULVERT
DRAIN
DEGREE
DEMOLITION
DETAIL
DROP INLET
DIAMETER
DIFFERENCE
DUCTILE IRON PIPE
DEEP INJECTION WELL
DETENTION POND
PUMP
DRIVE
DRAWING
DRIVEWAY APRON
DUAL ZONE MONITORING WELL
ELECTRIC, EAST
EACH
END OF CURVE
ECCENTRIC
EXISTING GROUND
ELBOW
ELECTRIC
ELEVATION
ELECTRICAL MANHOLE
END OF ALIGNMENT
EDGE OF PAVEMENT
EDGE OF PAVING
EQUAL
ELECTRICAL UNDERGROUND
END OF VERTICAL CURVE
EACH WAY
EXISTING
FLEXIBLE COUPLING / FLEXIBLE CONNECTION
FLANGE COUPLING ADAPTER
FIRE HYDRANT
FINAL / FINISHED
FLOW LINE
FLEXIBLE
FLANGE
FLANGE ADAPTER
FORCE MAIN
FORCE MAIN SANITARY SEWER
FIBER OPTIC OR CATV
FACE OF CURB
FIBERGLASS - REINFORCED PLASTIC
FIRE SERVICES
FABRICATED STEEL PIPE
FOOT
FOOTING
GAS
GALVANIZE(D)
GAS METER
GROUND
GALVANIZED STEEL PIPE
GATE VALVE
HOT DIPPED GALVANIZED
HIGH DENSITY POLYETHYLENE
HORIZONTAL
HIGH POINT
HIGH PRESSURE GAS MAIN
HEADWALL
HIGHWAY
HYDRANT
AB
ABC
AC
APPROX
ARV
ASTM
BC
BF
BFP
BFV
BLDG
BOA
BOC
BOP
BV
BVC
BYP
CATV
CB
CC
CFM
CI
CL OR C
CIPP
CLR
CML
CMLC
CMLSP
CMP
CLSM
CONC
CP
CPLG
CO
CONC
COORD
CSP
CTR
CU
CULV
D
DEG
DEMO
DET
DI
DIA
DIFF
DIP
DIW
DP
DPTA
DR
DWG
D/W
DZMW
E
EA
EC
ECC
EG
ELB / ELL
ELEC
ELEV/EL
EMH
EOA
EOP
EP
EQ
EUG
EVC
EW
EX/EXIST
FC
FCA
FH
FIN
FL
FLEX
FLG
FLGA
FM
FMSS
FO
FOC
FRP
FS
FSP
FT
FTG
G
GALV
GM
GND
GSP
GV
HDG
HDPE
HORIZ
HP
HPGM
HW
HWY
HYD
I
ID
INV
IRR
JNCT
LAT
LF
LONG
LT
MAX
MFR/MFR'S
MH
MISC
MIN
MJ
MON
N
NG
NIC
NO./NO'S
NTS
NW
OC
OD
OHE
OHU
OTF
PC
PCC
PCL
PERP
PH
PI
PL
PMP
PP
PROP
PRC
PSF
PSI
PT
PV
PVC
PVI
PVT
PVMT
QTY
RAD
RCP
RED
REF
REINF
REQ'D
REV
RR
RP
R/W
S
SD
SDDI
SDMH
SDVLT
SHLD
SHT
SIM
SPEC
SQ FT
SSCO
SSMH
SST
ST
STA
STD
STL
SW
TB
TELE
TG
TOC
TOP
TS
TYP
UGE
UGG
UGPB
UGTEL
UNKN
UNO
VC
VCP
VERT
VLT
VPI
W / WTR
W
WM
WTP
WV
WW
WWTP
WRF
WSTP
W/
INTERSECTION OF ANGLE
INSIDE DIAMETER
INVERT
IRRIGATION
JUNCTION
LATERAL
LINEAR FEET
LONGITUDINAL
LEFT
MAXIMUM
MANUFACTURER / MANUFACTURER'S
MANHOLE
MISCELLANEOUS
MINIMUM
MECHANICAL JOINT
MONUMENT
NORTH
NATURAL GAS
NOT IN CONTRACT
NUMBER / NUMBERS
NOT TO SCALE
NORTHWEST
ON CENTER
OUTSIDE DIAMETER
OVERHEAD ELECTRIC
OVERHEAD UTILITIES
OUTFALL
POINT OF CURVATURE
POINT OF COMPOUND CURVE
PARCEL PROPERTY LINE
PERPENDICULAR
POT HOLE
POINT OF INTERSECTION
PLATE / PROPERTY LINE
PUMP
POWER POLE
PROPERTY
POINT OF REVERSE CURVATURE
PER SQUARE FOOT
PER SQUARE INCH
POINT, POINT OF TANGENT
PLUG VALVE
POLYVINYL CHLORIDE
POINT OF VERTICAL INTERSECTION
POINT OF VERTICAL TANGENCY
PAVEMENT
QUANTITY
RADIUS
REINFORCED CONCRETE PIPE
REDUCER
REFERENCE
REINFORCED
REQUIRED
REVISION
RAILROAD
RADIUS POINT
RIGHT-OF-WAY
SLOPE, SOUTH
STORM DRAIN
STORM DRAIN DROP INLET
STORM DRAIN MANHOLE
STORM DRAIN VAULT
SHOULDER
SHEET
SIMULAR
SPECIFICATION
SQUARE FEET
SANITARY SEWER CLEANOUT
SANITARY SEWER MANHOLE
STAINLESS STEEL
STREET
STATION
STANDARD
STEEL
SOUTHWEST
THRUST BLOCK
TELEPHONE
TOP OF GRATE
TOP OF CONCRETE
TOP OF PIPE
TRAFFIC SIGNAL
TYPICAL
UNDERGROUND ELECTRIC
UNDERGROUND G
UNDERGROUND POWER BOX
UNDERGROUND TELEPHONE
UNKNOWN
UNLESS NOTED OTHERWISE
VERTICAL CURVE
VITRIFIED CLAY PIPE
VERTICAL
VAULT
VERTICAL POINT OF INTERSECTION
WATER
WEST
WATER METER
WATER TREATMENT PLAN
WATER VALVE
WASTEWATER
WASTE WATER TREATMENT PLANT
WATER RECLAMATION FACILITY
WATERSTOP
WITH
SOIL BORING LOCATIONS
SYMBOLS
MONUMENT
BENCH MARK
VERTICAL CONTROL POINT
SYMBOL DESCRIPTION
DIRECTION ARROW
FLOW ARROW
GAS VALVE
OPEN/CLOSED
FLOW/SLOPE
DIRECTION
GAS METER
IRON PIN
IRON ROD
MANHOLE (PROFILE)
MANHOLE (PLAN)
PULL BOX
TRANSIT POINT
POWER TOWER
ANCHOR POINT
SYMBOL DESCRIPTION
3 WAY PA SPEAKER
DATUM POINT
CATCH BASIN (SQUARE)
CATCH BASIN (ROUND)
CURB MANHOLE
HIGH LIGHT POLE
ROCK WALL
RIP RAP
PA SPEAKER
PROPERTY HOOK
2 WAY PA SPEAKER
4 WAY PA SPEAKER
BURIED VALVE
HEADWALL
TRAFFIC LIGHT POLE
TRAFFIC LIGHT POLE
SINGLE TRAFFIC
LIGHT POLE
X JUNCTION BOX
/ JUNCTION BOX
I JUNCTION BOX
GUYED LIGHT POLE
CABLE TV
UTILITY POLE
UTILITY POLE GUY WIRE
VALVE W/ OPERATOR
CLOSED VALVE
W/ OPERATOR
VALVE W/ OPERATOR
AND CONNECTION
CLOSED VALVE W/
OPERATOR AND
CONNECTION
VALVE W/ OPERATOR
AND TWO CONNECTIONS
CLOSED VALVE
W/ OPERATOR AND
TWO CONNECTIONS
PIPE CAP OR
CONNECTION
CHECK VALVE
CROSS
FIRE HYDRANT -
2 WAY
FIRE HYDRANT -
3 WAY
FLANGE
VALVE
VALVE W/
CONNECTION
CLOSED VALVE W/
CONNECTION
VALVE W/ TWO
CONNECTIONS
CLOSED VALVE W/
TWO CONNECTIONS
CLOSED VALVE
CAP OR TURN DOWN
PLUG VALVE
CLOSED
PLUG VALVE
REDUCER W/
CONNECTION
REDUCER W/
CONNECTION
REDUCER
REDUCER FLANGED
REDUCER W/ TWO
CONNECTIONS
GATE VALVE W/
BLIND FLANGE
AND CONNECTION
TEE W/ FLANGE
AND CONNECTIONS
TEE W/
CONNECTIONS
FLANGED TEE
(IN FEET)
RIP RAP
ELEVATION
ROADWAY GRADE
COORDINATES
CONCRETE PAVEMENT
SLOPE CALLOUT
SURFACE SLOPE
ASPHALT PAVEMENT
PLANT COORDINATES AT STRUCTURES
(OUTSIDE FACE AT FINISHED GRADE)
(SEE TABLE ON EACH
GUARD POST
2%
SECTIONPLAN
SPOT ELEVATION (FINISH ELEV)
CONTROL POINT
SPOT ELEVATION (AT PAVEMENT)
SPOT ELEVATION (AT DIRT)
SPOT ELEVATION (AT FLOWLINE)
SPOT ELEVATION (AT TOP CURB)
SPOT ELEVATION (AT HIGH POINT)
FIN SLAB
FIN SLAB/
PVMT
XX.X
XX.XX
XX.XX
XX.XX
(HP)
XX.XX
XX.XX
TC
FL
3:1 =
2:1 =
(FT/FT)
S=0.0100
S=0.0020
(FT/FT)
E 10000N 16000
X 1325.00
1328.2 EXISTING
LENGTH
CURVE NUMBER
EDGE OF PVMT
PT
RADIUS POINT
RADIUS
ANGLE
CLOCKWISE
PC
VAULT
METER
VAULT
METER
TEST BORING LOCATIONS
PERCOLATION
TEST LOCATIONS
IP
IR
DATUM
P
CTV
MC MC
PH POTHOLE/
POTHOLE NUMBER
DROP INLET
SHRUB/HEDGE
TREE
T TELEPHONE PEDESTAL
YARD HYDRANT
CO
CLEANOUT
AIR RELEASE VALVE
BLOW OFF VALVE
LIGHT
LIGHT POLE
PP
POWER POLE
SIGN/SIGN POST
ELECTRICAL MANHOLE
AND PULL BOX
REDUCER W/
FLANGE AND
CONNECTION
DROP MANHOLE
PARSHALL FLUME
OPERATOR/
OPERATOR CLOSED
HOSE BIBB
SERVICE CONNECTION
GATE
ROADWAY/PIPE CURVE
WITH ROADWAY/PIPE CURVES.)
GRADING & PAVING OR CIVIL PIPING DWG
ROADWAY/PIPE CURVES
COORDINATES
PATTERNING
ELEVATION/SLOPES
DESCRIPTIONSYMBOL
STAGING AREA
STABILIZED CONSTRUCTION
ENTRANCE
DRAINAGE DITCH OR
CHANNEL GRADE
NEW
OR OUTSIDE FACE
OF CURB
ALL SYMBOLS SHOWN AS
NEW. EXISTING SYMBOLS
ARE SCREENED.
XX
PHXX
XX
X
X
X
X
XX
Q
PROJECT NO.
LA
ST
S
AV
ED
B
Y:
FILE NAME:
MAB
AMR
LDM
00G04
GENERAL
SYMBOLS 2
7126I1000G04.dwg ar ic ar do
7126I10
/6
/2
3:
:3
PM
Pl ot
D at e:
DATEREV BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
7126I.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OFNOVEMBER 2025
COLLIER COUNTY
NORTHEAST WRF/WTP -DIW CONVEYANCE
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
301 North Cattlemen Road, Suite 302 Sarasota, FL 34232
Phone: 941-371-9832
AND SEALED BY MATTHEW S. LOVE ON THE DATE
ADJACENT TO THE SEAL ON THE COVER SHEET.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE BE VERIFIED ON ANY ELECTRONIC
X
X X
X X
X X
X X
X X
X X
X X
X
X X
X X
X
X X
XXXXXXXX
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
WM WMWMWM
WM WM
DATEREV BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
7126I.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OFNOVEMBER 2025
COLLIER COUNTY
NORTHEAST WRF/WTP -DIW CONVEYANCE
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
301 North Cattlemen Road, Suite 302 Sarasota, FL 34232
Phone: 941-371-9832
AND SEALED BY MATTHEW S. LOVE ON THE DATE
ADJACENT TO THE SEAL ON THE COVER SHEET.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE BE VERIFIED ON ANY ELECTRONIC
COPIES.
PROJECT NO.
LA
ST
S
AV
ED
B
Y:
FILE NAME:
MAB
AMR
LDM
00G05
GENERAL
OVERALL SITE PLAN
7126I1000G05.dwg ar ic ar do
7126I10
/6
/2
3:
:4
PM
Pl ot
D at e:
FILE:
PLAN
7126I1000C100
DP
POND #2G
A 00G06
400'200'0 100'
SCALE: 1" = 200'
FUTURE COLLECTIONS &
DISTRIBUTION BUILDING
FACILITY
ENTRANCE
FUTURE
WTP
FUTURE
WRF
INTERIM
WWTP
GENERAL NOTE:
1. PROJECT SCOPE OF WORK SHOWN IN BOLD.
AutoCAD SHX Text X
AutoCAD SHX Text
W M
W M
W M
W M
WM WM WM WM
WM WM WM WM WM
INJECTION WELL #1
N 717413.98 E 796869.90
MONITORING WELL
N 717413.98 E 797019.90
INJECTION WELL #2
N 717413.98 E 797169.90
DATEREV BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
7126I.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OFNOVEMBER 2025
COLLIER COUNTY
NORTHEAST WRF/WTP -DIW CONVEYANCE
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
301 North Cattlemen Road, Suite 302 Sarasota, FL 34232
Phone: 941-371-9832
AND SEALED BY MATTHEW S. LOVE ON THE DATE
ADJACENT TO THE SEAL ON THE COVER SHEET.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE BE VERIFIED ON ANY ELECTRONIC
COPIES.
PROJECT NO.
LA
ST
S
AV
ED
B
Y:
FILE NAME:
MAB
AMR
LDM
00G06
GENERAL
ENLARGED SITE PLAN OF DEEP INJECTION WELL
7126I1000G06.dwg ar ic ar do
7126I10
/6
/2
3:
:4
PM
Pl ot
D at e:
FUTURE COLLECTIONS &
DISTRIBUTION BUILDING
80'40'0 20'
SCALE: 1" = 40'
DP-3
POND #2G
SCALE:
FILE:
PLAN
7126I1000C100
1" = 40'A
150'-0" 150'-0"
GENERAL NOTES:
1. AFTER WELL CONSTRUCTION ACTIVITIES ARE
COMPLETE, THE INJECTION WELL PADS ARE NOT,
UNLESS SPECIFIC APPROVAL IS OBTAINED FROM
THE DEPARTMENT, TO BE USED FOR STORAGE
OF ANY MATERIAL OR EQUIPMENT AT ANY TIME
2. CONTRACTOR SHALL CONDUCT A SITE SURVEY
PRIOR TO CONSTRUCTION. SEE SPECIFICATION
SECTION 13 40 00 FOR SURVEY REQUIREMENTS.
3. SITE IS CURRENTLY UNDER DEVELOPMENT.
CONTRACTOR SHALL USE EXISTING
CONSTRUCTION ACCESS ROADS FOR SITE
ACCESS.
4. CONTRACTOR CAN UTILIZE AREA TO THE EAST OF
THE INJECTION WELL SITES FOR A LAYDOWN
AREA. LAYDOWN AREA SHALL NOT ENCROACH
UPON ACCESS TO EXISTING STRUCTURES.
PROJECT NO.
L A
S T
S
V
E D
Y
FILE NAME:
MAB
AMR
LDM
00G07
GENERAL
INJECTION WELLS AND MONITORING WELL
PROCESS FLOW DIAGRAM
7126I1000G07.dwg
A l a i c o
7126I10
A
M P l o t
D a t e
DATE
REV
BY
DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
7126I.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OFNOVEMBER 2025
COLLIER COUNTY
NORTHEAST WRF/WTP -DIW CONVEYANCE
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
301 North Cattlemen Road, Suite 302
Sarasota, FL 34232
Phone: 941-371-9832
CA No. 00008571
10/25 RC
BID SET
AND SEALED BY MATTHEW S. LOVE ON THE DATE
ADJACENT TO THE SEAL ON THE COVER SHEET.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE BE VERIFIED ON ANY ELECTRONIC
COPIES.
GATE VALVE
(TYP)
FROM FUTURE WTP
FROM WWTP
CONTAINMENT AREA
(TYP)
DEEP INJECTION
WELL #1
DEEP INJECTION
WELL #2
AIR COMBINATION
VALVE. DRAIN INTO
CONTAINMENT AREA
(TYP)
CHECK VALVE
(TYP)
WELL ANNULUS
PRESSURE TANK
NITROGEN
CYLINDERS
SAMPLE PANEL
SWING CHECK
VALVE (TYP)
BALL VALVE (TYP)
DUAL ZONE
MONITORING WELL
PLUG VALVE
(TYP)
CHECK
VALVE
(TYP)
PRESSURE RELIEF
VALVE (TYP)
GENERAL NOTES:
1. SEE DRAWING G02 FOR PIPE SCHEDULE
WELL ANNULUS
PRESSURE TANK
NITROGEN
CYLINDERS
DIIQ
ROC
24" DIIQ/ROC
2" SPD
1/2" NG
1" ASF
FLEXIBLE
CONNECTION
FLEXIBLE
CONNECTION
FLEXIBLE
CONNECTION
PLUG VALVE WITH
ACTUATOR (TYP)
SAMPLE
POINT
(TYP)
SUMP
2" SPD
1 1/4" MWD
1 1/4" MWD
2" SPD
3-WAY BALL
VALVE (TYP)
2" SPD
1" DR 1" DR
STRAINER:
WYE TYPE
(TYP)
PRESSURE
REGULATOR
(TYP)
SP-1
DIW SUMP
PUMP #1
SAM-1
SHALLOW
ZONE SAMPLE
PUMP
SAM-2
DEEP ZONE
SAMPLE
PUMP
SP-3
DZMW SUMP
PUMP
SP-2
DIW SUMP
PUMP #2
M
M
M
M
FLOW METER
FLOW METER
(TYP)
FLOW METER
AIR RELEASE
VALVE (TYP)
PLUG VALVE
WITH ACTUATOR
(TYP)
36" DIIQ/ROC
24" DIIQ/ROC
24" DIIQ/ROC
PROJECT NO.
LA
ST
S
AV
ED
B
Y:
FILE NAME:
MNT
MNT
JRB
00C01
GENERAL
NOTES & LEGENDS
20203210-001_Cover.dwg
M ic ha el
.T is eo
71261.10
JOHNSON ENGINEERING, LLC.
2122 JOHNSON STREET
FORT MYERS, FLORIDA 33901
PHONE: (239) 334-0046
E.R. #642 & L.B. #642
COLLIER COUNTY PUBLIC UTILITIES STANDARD DETAIL NOTES:
ALL REFERENCES TO COLLIER COUNTY PUBLIC UTILITIES STANDARD DETAILS ARE FROM
THE 2025 COLLIER COUNTY UTILITIES OPERATION AND MAINTENANCE MANUAL. THESE
STANDARD DETAILS WERE PREPARED BY OR AT THE DIRECTION OF COLLIER COUNTY
AND WERE FURNISHED TO JOHNSON ENGINEERING, INC.
THE DESIGN STANDARDS REFERENCED WITHIN THIS PLAN SET HAVE BEEN
INCORPORATED HEREIN VERBATIM AS SET FORTH WITHIN THE ABOVE REFERENCED
COLLIER COUNTY OPERATION AND MAINTENANCE MANUAL.
PRINTING AND PLOTTING NOTE:
PRINTING FULL SIZE OR 22"X34" PLANS:
· 22"X34" PLANS ARE MEANT TO BE PLOTTED AT 20 SCALE.
(SEE INDIVIDUAL SCALE BARS ON EACH SHEET FOR DEVIATIONS)
· WHEN PRINTING FULL SIZE PLANS (22"X34") MAKE SURE THE PROPER SIZE PAPER IS
USED, FAILURE TO DO SO WILL RESULT IN PLANS THAT ARE NOT TO SCALE.
· WHEN PRINTING 22"X34" PDF'S FROM ADOBE SELECT "ACTUAL SIZE" & "CHOOSE PAPER
SOURCE BY PDF PAGE SIZE"
PRINTING 1/2 SIZE OR 11"X17" PLANS:
· 11"X17" PLANS ARE MEANT TO BE PLOTTED AT 40 SCALE.
(SEE INDIVIDUAL SCALE BARS ON EACH SHEET FOR DEVIATIONS)
· WHEN PRINTING 1/2 SIZE PLANS (11"X17") MAKE SURE THE PROPER SIZE PAPER IS
USED, FAILURE TO DO SO WILL RESULT IN PLANS THAT ARE NOT TO SCALE.
· WHEN PRINTING 11"X17" PDF'S FROM ADOBE SELECT "ACTUAL SIZE" & "CHOOSE PAPER
SOURCE BY PDF PAGE SIZE"
SYMBOLS
A
UTILITY LINETYPES
PROPOSEDEXISTING
IRR
FM
WM
RW
SS
PR. 8'' WM
PR. 8'' FM
PR. 8'' IRR
PR. 8'' IQ
PR. 8'' RW
PR. 8'' SS
RU
PR. 8'' RU
IQ
ABBREVIATIONS
DATEREV BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
SHEET NO.
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
301 North Cattlemen Road, Suite 302 Sarasota, FL 34232
Phone: 941-371-9832 CA No. 00008571
THIS DOCUMENT HAS BEEN DIGITALLY SIGNED
AND SEALED BY JARED ROY BROWN, PE ON THE
DATE ADJACENT TO THE SEAL ON THE COVER
SHEET.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE BE VERIFIED ON ANY ELECTRONIC
COPIES.
/5
/2
4:
:4
PM
Pl ot
D at e:
STATE OF
NO. 60024
J A
RED ROY BROW
N
P
RO
FESS I ONA L ENG I N
EE
R
L I CENSE
F L O R I D A
ALL "FUTURE" UTILITIES REFERENCES ON THESE
PLANS ARE CURRENTLY UNDER DESIGN.
REFERENCE TO SAID UTILITIES ARE FOR INFORMATION
PURPOSES ONLY.
"FUTURE" UTILITIES WILL BE ADJUSTED BASED ON
AS-BUILIT LOCATION OF PROPOSED DIIQ MAIN.
"FUTURE" UTILITY LINETYPES
.2
36" DIIQ - HDPE DR11
ELEVATIONS SHOWN HEREON ARE BASED ON NORTH AMERICAN VERTICAL DATUM 1988 (NAVD '88).
CONVERSION FACTOR TO NATIONAL GEODETIC VERTICAL DATUM 1929 (NGVD '29) IS (+) 1.257
ALIGNMENT A
ALIGNMENT B
ALIGNMENT C
ALIGNMENT D
ALIGNMENT E
SEE SHEET 10
SEE SHEET 11
SEE SHEET 12
SEE SHEET 13
SEE SHEET 14 SEE SHEET 15 SEE SHEET 16
SEE SHEET 17
SEE SHEET 18
DIIQ METER ASSEMBLY
SEE SHEET 19
DEEP INJECTION
WELL #2
DEEP INJECTION
WELL #1
JOHNSON ENGINEERING, LLC.
2122 JOHNSON STREET
FORT MYERS, FLORIDA 33901
PHONE: (239) 334-0046
E.R. #642 & L.B. #642DATEREV BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
SHEET NO.
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
301 North Cattlemen Road, Suite 302 Sarasota, FL 34232
Phone: 941-371-9832 CA No. 00008571
THIS DOCUMENT HAS BEEN DIGITALLY SIGNED
AND SEALED BY JARED ROY BROWN, PE ON THE
DATE ADJACENT TO THE SEAL ON THE COVER
SHEET.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE BE VERIFIED ON ANY ELECTRONIC
COPIES.
/5
/2
4:
:0
PM
Pl ot
D at e:
STATE OF
NO. 60024
J A
RED ROY BROW
N
P
RO
FESS I ONA L ENG I N
EE
R
L I CENSE
F L O R I D A
PROJECT NO.
LA
ST
S
AV
ED
B
Y:
FILE NAME:
MNT
MNT
JRB
00C02
GENERAL
KEY MAP
20203210-001_PP.dwg
M ic ha el
.T is eo
71261.10
8" IQ MAIN
DISPOSAL SPRAY FIELD
(NOT PART OF THIS PROJECT)
ALIGNMENT F
MONITORING WELL
36" DIIQ - PLUG ON VALVE
FOR FUTURE CONNECTION
36" DIIQ - GATE VALVE
36" DIIQ - 45° HOR BEND
36" DIIQ - TEE 36" DIIQ - HDPE DR11
36" DIIQ - GATE VALVE
36"X16" DIIQ - REDUCER
16" DIIQ - HDPE DR11
16" DIIQ - 45° VERT BEND
16" DIIQ - 45° VERT BEND
36" DIIQ - 45° HOR BEND
SEE SHEET 11 FOR
PROFILE OF THIS 16" DIIQ
0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00
8" IQ MAIN
DISPOSAL SPRAY FIELD
(NOT PART OF THIS PROJECT)
DIIQ METER ASSEMBLY
SEE SHEET 19 FOR
DETAILS & CROSS SECTIONS
FUTURE 12" GRND
(BY OTHERS)
FUTURE 8" IRG
(BY OTHERS)
FUTURE 42" RJW
(BY OTHERS)
FUTURE 12" PVC DRAIN
(BY OTHERS)
FUTURE 18" PDD
(BY OTHERS)
FUTURE 8" FPW
(BY OTHERS)
FUTURE 6" PLW
(BY OTHERS)
FUTURE 36" REW
(BY OTHERS)
FUTURE 12" PVC DRAIN
(BY OTHERS)
FUTURE 12" PVC DRAIN
(BY OTHERS)
FUTURE 8" IRG
(BY OTHERS)
FUTURE 18" PDD
(BY OTHERS)
FUTURE 12" PVC DRAIN
(BY OTHERS)
FUTURE 8" FPW
(BY OTHERS)
FUTURE 8" IRG
(BY OTHERS)
FUTURE 6" PLW
(BY OTHERS)
FUTURE 24" DUCTBANK
(BY OTHERS)
Hor. Scale: 1" = 20', Vert. Scale: 1" = 2'Alignment A Sta: 0+00 to Sta: 4+00
0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00
36" DIIQ - 45° HOR BEND
36" DIIQ - GATE VALVE
36" DIIQ - PLUG ON VALVE
FOR FUTURE CONNECTION
0.5'
36" DIIQ - 45° HOR BEND
9.
0'
M
IN
. D
EP
TH
PROPOSED
FINISHED GRADE
(BY OTHERS)
2.5'
FUTURE 42" RJW
(BY OTHERS)
FUTURE 42" RJW
(BY OTHERS)
FUTURE 36" REW
(BY OTHERS)
FUTURE 12" PVC DRAIN
(BY OTHERS)
FUTURE 12" PVC DRAIN
(BY OTHERS)
FUTURE 30" RCP
(BY OTHERS)
FUTURE 8" IRG
(BY OTHERS)
FUTURE 6" PLW
(BY OTHERS)
FUTURE 18" PDD
(BY OTHERS)
FUTURE 12" PVC DRAIN
(BY OTHERS)
FUTURE 8" FPW
(BY OTHERS)
36" DIIQ - HDPE DR11
36" DIIQ - GATE VALVE
36" DIIQ - TEE
FOR CONTINUATION SEE SHEET 11
ELEVATIONS SHOWN HEREON ARE BASED ON NORTH AMERICAN VERTICAL DATUM 1988 (NAVD '88).
CONVERSION FACTOR TO NATIONAL GEODETIC VERTICAL DATUM 1929 (NGVD '29) IS (+) 1.257
JOHNSON ENGINEERING, LLC.
2122 JOHNSON STREET
FORT MYERS, FLORIDA 33901
PHONE: (239) 334-0046
E.R. #642 & L.B. #642DATEREV BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
SHEET NO.
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
301 North Cattlemen Road, Suite 302 Sarasota, FL 34232
Phone: 941-371-9832 CA No. 00008571
THIS DOCUMENT HAS BEEN DIGITALLY SIGNED
AND SEALED BY JARED ROY BROWN, PE ON THE
DATE ADJACENT TO THE SEAL ON THE COVER
SHEET.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE BE VERIFIED ON ANY ELECTRONIC
COPIES.
/5
/2
4:
:4
PM
Pl ot
D at e:
STATE OF
NO. 60024
J A
RED ROY BROW
N
P
RO
FESS I ONA L ENG I N
EE
R
L I CENSE
F L O R I D A
PROJECT NO.
LA
ST
S
AV
ED
B
Y:
FILE NAME:
MNT
MNT
JRB
00C03
GENERAL
ALIGNMENT A 0+00_TO_4+00
20203210-001_PP.dwg
M ic ha el
.T is eo
71261.10
ALL "FUTURE" UTILITIES REFERENCES ON THESE PLANS ARE CURRENTLY UNDER DESIGN.
REFERENCE TO SAID UTILITIES ARE FOR INFORMATION PURPOSES ONLY.
"FUTURE" UTILITIES WILL BE ADJUSTED BASED ON AS-BUILIT LOCATION OF PROPOSED DIIQ MAIN.
DIIQ METER ASSEMBLY
SEE SHEET 19 FOR
DETAILS & CROSS SECTIONS
36" DIIQ - HDPE DR11
2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00
16" DIIQ - HDPE DR11
CONTRACTOR TO VERIFY THAT BELL OF
DRAINAGE PIPE WILL NOT BE IN CONFLICT.
CROSSING MAY BE ADJUSTED (NORTH OR SOUTH)
AS NEEDED TO ALLOW FOR INSTALLATION
FUTURE 6" PLW
(BY OTHERS)
FUTURE 30" RCP
(BY OTHERS)
FUTURE 8" IRG
(BY OTHERS)
FUTURE 18" PDD
(BY OTHERS)
FUTURE 12" PVC DRAIN
(BY OTHERS)
FUTURE 8" FPW
(BY OTHERS)
FUTURE 8" IRG
(BY OTHERS)
FUTURE 15" RCP
(BY OTHERS)
FUTURE 36" FA
(BY OTHERS)
FUTURE 24" EBI
(BY OTHERS)
FUTURE 16" EBE
(BY OTHERS)
36" DIIQ - 45° HOR BEND
36" DIIQ - PLUG ON VALVE
FOR FUTURE CONNECTION
36" DIIQ - GATE VALVE
36" DIIQ - TEE
36" DIIQ - 45° HOR BEND
36" DIIQ - GATE VALVE
16" DIIQ - 45° VERT BEND
16" DIIQ - 45° VERT BEND
36"X16" DIIQ - REDUCER
Hor. Scale: 1" = 20', Vert. Scale: 1" = 2'Alignment B Sta: 3+00 to Sta: 7+00
3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00
Hor. Scale: 1" = 20', Vert. Scale: 1" = 2'Alignment B (Offset) Sta: 2+50 to Sta: 3+50
2+50 3+00 3+50
36" DIIQ - 45° HOR BEND
36" DIIQ - HDPE DR11
PROPOSED
FINISHED GRADE
(BY OTHERS)
9.
0'
M
IN
. D
EP
TH
2.7' 1.9'
2.7'
5.8'5.8'
PROPOSED DEPTH
NOT FOUND
IN FUTURE PLANSFUTURE 8" FPW
(BY OTHERS)
FUTURE 8" IRG
(BY OTHERS)
FUTURE 36" FA
(BY OTHERS)
FUTURE 15" RCP
(BY OTHERS) FUTURE 24" EBI
(BY OTHERS)
FUTURE 16" EBE
(BY OTHERS)
36" DIIQ - TEE
36"X16" DIIQ - REDUCER
16" DIIQ - HDPE DR11
9.
0'
M
IN
. D
EP
TH
3.0'
0.6' 1.3'
PROPOSED
FINISHED GRADE
(BY OTHERS)
36" DIIQ - 45° HOR BEND
16" DIIQ - 90° HOR BEND
16" DIIQ - 45° VERT BEND
0.6'
16" DIIQ - 45° VERT BEND
M
AT
C H
LI
N
E
SE
E
SH
EE
T
FOR CONTINUATION SEE SHEET 10
ELEVATIONS SHOWN HEREON ARE BASED ON NORTH AMERICAN VERTICAL DATUM 1988 (NAVD '88).
CONVERSION FACTOR TO NATIONAL GEODETIC VERTICAL DATUM 1929 (NGVD '29) IS (+) 1.257
JOHNSON ENGINEERING, LLC.
2122 JOHNSON STREET
FORT MYERS, FLORIDA 33901
PHONE: (239) 334-0046
E.R. #642 & L.B. #642DATEREV BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
SHEET NO.
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
301 North Cattlemen Road, Suite 302 Sarasota, FL 34232
Phone: 941-371-9832 CA No. 00008571
THIS DOCUMENT HAS BEEN DIGITALLY SIGNED
AND SEALED BY JARED ROY BROWN, PE ON THE
DATE ADJACENT TO THE SEAL ON THE COVER
SHEET.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE BE VERIFIED ON ANY ELECTRONIC
COPIES.
/5
/2
4:
:1
PM
Pl ot
D at e:
STATE OF
NO. 60024
J A
RED ROY BROW
N
P
RO
FESS I ONA L ENG I N
EE
R
L I CENSE
F L O R I D A
PROJECT NO.
LA
ST
S
AV
ED
B
Y:
FILE NAME:
MNT
MNT
JRB
00C04
GENERAL
ALIGNMENT B 2+50_TO_7+00
20203210-001_PP.dwg
M ic ha el
.T is eo
71261.10
ALL "FUTURE" UTILITIES REFERENCES ON THESE PLANS ARE CURRENTLY UNDER DESIGN.
36" DIIQ - HDPE DR11
36" DIIQ - HDPE DR11
7+00 7+50 8+00 8+50 9+00 9+50 10+00 10+50 11+00
+5
+0
A
8" IQ MAIN
DISPOSAL SPRAY FIELD
(NOT PART OF THIS PROJECT)
REEL CONNECTION POINTS
DISPOSAL SPRAY FIELD
(NOT PART OF THIS PROJECT)
REEL CONNECTION POINTS
DISPOSAL SPRAY FIELD
(NOT PART OF THIS PROJECT)
.9
FUTURE 24" RS
(BY OTHERS)
FUTURE 24" RS
(BY OTHERS)
FUTURE 8" IRG
(BY OTHERS)
FUTURE 60" RCP
(BY OTHERS)
FUTURE 8" IRG
(BY OTHERS)
FUTURE 8" FPW
(BY OTHERS)
36" DIIQ - 45° HOR BEND
36" DIIQ - 45° HOR BEND
36" DIIQ - 45° VERT BEND
36" DIIQ - 45° VERT BEND
AIR RELEASE VALVE
Hor. Scale: 1" = 20', Vert. Scale: 1" = 2'Alignment B Sta: 7+00 to Sta: 12+00
7+00 7+50 8+00 8+50 9+00 9+50 10+00 10+50 11+00 11+50 12+00
36" DIIQ - HDPE DR11
36" DIIQ - 45° HOR BEND
36" DIIQ - 45° HOR BEND
36" DIIQ - 45° VERT BEND
PROPOSED
FINISHED GRADE
(BY OTHERS)
9.
0'
M
IN
. D
EP
TH
3.
0'
M
IN
D
EP
TH
5.8' 5.8'
1.9'1.9'
FUTURE 24" RS
(BY OTHERS)
FUTURE 24" RS
(BY OTHERS)
FUTURE 8" IRG
(BY OTHERS)
FUTURE 8" FPW
(BY OTHERS)
36" DIIQ - 45° VERT BEND
A
AIR RELEASE VALVE
MATCHLINE SEE SHEET 13
M
AT
C H
LI
N
E
SE
E
SH
EE
T
FOR CONTINUATION SEE SHEET 13
ELEVATIONS SHOWN HEREON ARE BASED ON NORTH AMERICAN VERTICAL DATUM 1988 (NAVD '88).
CONVERSION FACTOR TO NATIONAL GEODETIC VERTICAL DATUM 1929 (NGVD '29) IS (+) 1.257
JOHNSON ENGINEERING, LLC.
2122 JOHNSON STREET
FORT MYERS, FLORIDA 33901
PHONE: (239) 334-0046
E.R. #642 & L.B. #642DATEREV BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
SHEET NO.
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
301 North Cattlemen Road, Suite 302 Sarasota, FL 34232
Phone: 941-371-9832 CA No. 00008571
THIS DOCUMENT HAS BEEN DIGITALLY SIGNED
AND SEALED BY JARED ROY BROWN, PE ON THE
DATE ADJACENT TO THE SEAL ON THE COVER
SHEET.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE BE VERIFIED ON ANY ELECTRONIC
COPIES.
/5
/2
4:
:4
PM
Pl ot
D at e:
STATE OF
NO. 60024
J A
RED ROY BROW
N
P
RO
FESS I ONA L ENG I N
EE
R
L I CENSE
F L O R I D A
PROJECT NO.
LA
ST
S
AV
ED
B
Y:
FILE NAME:
MNT
MNT
JRB
00C05
GENERAL
ALIGNMENT B 7+00_TO_12+00
20203210-001_PP.dwg
M ic ha el
.T is eo
71261.10
ALL "FUTURE" UTILITIES REFERENCES ON THESE PLANS ARE CURRENTLY UNDER DESIGN.
36" DIIQ - 45° HOR BEND
36" DIIQ - 45° HOR BEND
36" DIIQ - 45° HOR BEND
36" DIIQ - 45° HOR BEND
36" DIIQ - HDPE DR11
36" DIIQ - HDPE DR11
36" DIIQ - 45° VERT BEND
36" DIIQ - 45° VERT BEND
36" DIIQ - HDPE DR11
AIR RELEASE VALVE
10+80
11+00
11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50
16+00
16+50
16+70
A
FUTURE 60" RCP
(BY OTHERS)
FUTURE 8" IRG
(BY OTHERS)
FUTURE 6" PLW
(BY OTHERS)
FUTURE 4" PW
(BY OTHERS)
FUTURE 8" IRG
(BY OTHERS)
FUTURE 4" PW
(BY OTHERS)
FUTURE 8" FPW
(BY OTHERS)
Hor. Scale: 1" = 20', Vert. Scale: 1" = 2'Alignment C Sta: 11+00 to Sta: 16+50
11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50
36" DIIQ - 45° HOR BEND
36" DIIQ - 45° HOR BEND
36" DIIQ - 45° HOR BEND
36" DIIQ - HDPE DR11
36" DIIQ - 45° HOR BEND
PROPOSED
FINISHED GRADE
(BY OTHERS)
3.
0'
M
IN
D
EP
TH
36" DIIQ - 45° VERT BEND
36" DIIQ - 45° VERT BEND
A
AIR RELEASE VALVE
FOR CONTINUATION SEE SHEET 12
FOR CONTINUATION SEE SHEET 14
MATCHLIN
E SEE SHEET 14
MATCHLIN
E SEE SHEET 12
ELEVATIONS SHOWN HEREON ARE BASED ON NORTH AMERICAN VERTICAL DATUM 1988 (NAVD '88).
CONVERSION FACTOR TO NATIONAL GEODETIC VERTICAL DATUM 1929 (NGVD '29) IS (+) 1.257
JOHNSON ENGINEERING, LLC.
2122 JOHNSON STREET
FORT MYERS, FLORIDA 33901
PHONE: (239) 334-0046
E.R. #642 & L.B. #642DATEREV BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
SHEET NO.
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
301 North Cattlemen Road, Suite 302 Sarasota, FL 34232
Phone: 941-371-9832 CA No. 00008571
THIS DOCUMENT HAS BEEN DIGITALLY SIGNED
AND SEALED BY JARED ROY BROWN, PE ON THE
DATE ADJACENT TO THE SEAL ON THE COVER
SHEET.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE BE VERIFIED ON ANY ELECTRONIC
COPIES.
/5
/2
4:
:2
PM
Pl ot
D at e:
STATE OF
NO. 60024
J A
RED ROY BROW
N
P
RO
FESS I ONA L ENG I N
EE
R
L I CENSE
F L O R I D A
PROJECT NO.
LA
ST
S
AV
ED
B
Y:
FILE NAME:
MNT
MNT
JRB
00C06
GENERAL
ALIGNMENT C 11+00_TO_16+50
20203210-001_PP.dwg
M ic ha el
.T is eo
71261.10
ALL "FUTURE" UTILITIES REFERENCES ON THESE PLANS ARE CURRENTLY UNDER DESIGN.
+5
+0
16+50 17+00 17+50 18+00 18+50 19+00 19+50 20+00 20+50 21+00 21+50
FUTURE 6" PLW
(BY OTHERS)
FUTURE 4" PW
(BY OTHERS)
FUTURE 8" IRG
(BY OTHERS)
FUTURE 4" PW
(BY OTHERS)
FUTURE 8" IRG
(BY OTHERS)
36" DIIQ - 45° HOR BEND
36" DIIQ - 45° HOR BEND
EXISTING 30" RCP
Hor. Scale: 1" = 20', Vert. Scale: 1" = 2'Alignment D Sta: 16+00 to Sta: 21+50
16+00 16+50 17+00 17+50 18+00 18+50 19+00 19+50 20+00 20+50 21+00 21+50
36" DIIQ - 45° HOR BEND
36" DIIQ - HDPE DR11
PROPOSED
FINISHED GRADE
(BY OTHERS)
1.1'
3.
0'
M
IN
D
EP
TH
M
AT
C H
LI
N
E
SE
E
SH
EE
T
15MATCHLINE SEE SHEET 13
FOR CONTINUATION SEE SHEET 13
ELEVATIONS SHOWN HEREON ARE BASED ON NORTH AMERICAN VERTICAL DATUM 1988 (NAVD '88).
CONVERSION FACTOR TO NATIONAL GEODETIC VERTICAL DATUM 1929 (NGVD '29) IS (+) 1.257
JOHNSON ENGINEERING, LLC.
2122 JOHNSON STREET
FORT MYERS, FLORIDA 33901
PHONE: (239) 334-0046
E.R. #642 & L.B. #642DATEREV BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
SHEET NO.
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
301 North Cattlemen Road, Suite 302 Sarasota, FL 34232
Phone: 941-371-9832 CA No. 00008571
THIS DOCUMENT HAS BEEN DIGITALLY SIGNED
AND SEALED BY JARED ROY BROWN, PE ON THE
DATE ADJACENT TO THE SEAL ON THE COVER
SHEET.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE BE VERIFIED ON ANY ELECTRONIC
COPIES.
/5
/2
4:
:5
PM
Pl ot
D at e:
STATE OF
NO. 60024
J A
RED ROY BROW
N
P
RO
FESS I ONA L ENG I N
EE
R
L I CENSE
F L O R I D A
PROJECT NO.
LA
ST
S
AV
ED
B
Y:
FILE NAME:
MNT
MNT
JRB
00C07
GENERAL
ALIGNMENT D 16+00_TO_21+50
20203210-001_PP.dwg
M ic ha el
.T is eo
71261.10
ALL "FUTURE" UTILITIES REFERENCES ON THESE PLANS ARE CURRENTLY UNDER DESIGN.
21+50 22+00 22+50 23+00 23+50 24+00 24+50 25+00 25+50 26+00 26+50 27+00
36" DIIQ - HDPE DR11
FUTURE 54" RCP
(BY OTHERS)
FUTURE 8" IRG
(BY OTHERS)
Hor. Scale: 1" = 20', Vert. Scale: 1" = 2'Alignment D Sta: 21+50 to Sta: 27+00
21+50 22+00 22+50 23+00 23+50 24+00 24+50 25+00 25+50 26+00 26+50 27+00
36" DIIQ - HDPE DR11
PROPOSED
FINISHED GRADE
(BY OTHERS)
1.7'
3.
0'
M
IN
D
EP
TH
FUTURE 54" RCP
(BY OTHERS)
M
AT
C H
LI
N
E
SE
E
SH
EE
T
M
AT
C H
LI
N
E
SE
E
SH
EE
T
ELEVATIONS SHOWN HEREON ARE BASED ON NORTH AMERICAN VERTICAL DATUM 1988 (NAVD '88).
CONVERSION FACTOR TO NATIONAL GEODETIC VERTICAL DATUM 1929 (NGVD '29) IS (+) 1.257
JOHNSON ENGINEERING, LLC.
2122 JOHNSON STREET
FORT MYERS, FLORIDA 33901
PHONE: (239) 334-0046
E.R. #642 & L.B. #642DATEREV BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
SHEET NO.
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
301 North Cattlemen Road, Suite 302 Sarasota, FL 34232
Phone: 941-371-9832 CA No. 00008571
THIS DOCUMENT HAS BEEN DIGITALLY SIGNED
AND SEALED BY JARED ROY BROWN, PE ON THE
DATE ADJACENT TO THE SEAL ON THE COVER
SHEET.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE BE VERIFIED ON ANY ELECTRONIC
COPIES.
/5
/2
4:
:3
PM
Pl ot
D at e:
STATE OF
NO. 60024
J A
RED ROY BROW
N
P
RO
FESS I ONA L ENG I N
EE
R
L I CENSE
F L O R I D A
PROJECT NO.
LA
ST
S
AV
ED
B
Y:
FILE NAME:
MNT
MNT
JRB
00C08
GENERAL
ALIGNMENT D 21+50_TO_27+00
20203210-001_PP.dwg
M ic ha el
.T is eo
71261.10
ALL "FUTURE" UTILITIES REFERENCES ON THESE PLANS ARE CURRENTLY UNDER DESIGN.
27+00 27+50 28+00 28+50 29+00 29+50 30+00 30+50 31+00 31+50 32+00 32+50
FUTURE 15" RCP
(BY OTHERS)
FUTURE 8" IRG
(BY OTHERS)
FUTURE 8" IRG
(BY OTHERS)
FUTURE 15" RCP
(BY OTHERS)
FUTURE 4" SAN
(BY OTHERS)
FUTURE 3" RS
(BY OTHERS)
Hor. Scale: 1" = 20', Vert. Scale: 1" = 2'Alignment D Sta: 27+00 to Sta: 32+50
27+00 27+50 28+00 28+50 29+00 29+50 30+00 30+50 31+00 31+50 32+00 32+50
36" DIIQ - HDPE DR11
PROPOSED
FINISHED GRADE
(BY OTHERS)
3.
0'
M
IN
D
EP
TH
2.3' 2.6'
3.
0'
M
IN
D
EP
TH
FUTURE 15" RCP
(BY OTHERS)
FUTURE 8" IRG
(BY OTHERS)
FUTURE 8" IRG
(BY OTHERS)
FUTURE 4" SAN
(BY OTHERS)
FUTURE 3" RS
(BY OTHERS)
M
AT
C H
LI
N
E
SE
E
SH
EE
T
M
AT
C H
LI
N
E
SE
E
SH
EE
T
ELEVATIONS SHOWN HEREON ARE BASED ON NORTH AMERICAN VERTICAL DATUM 1988 (NAVD '88).
CONVERSION FACTOR TO NATIONAL GEODETIC VERTICAL DATUM 1929 (NGVD '29) IS (+) 1.257
JOHNSON ENGINEERING, LLC.
2122 JOHNSON STREET
FORT MYERS, FLORIDA 33901
PHONE: (239) 334-0046
E.R. #642 & L.B. #642DATEREV BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
SHEET NO.
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
301 North Cattlemen Road, Suite 302 Sarasota, FL 34232
Phone: 941-371-9832 CA No. 00008571
THIS DOCUMENT HAS BEEN DIGITALLY SIGNED
AND SEALED BY JARED ROY BROWN, PE ON THE
DATE ADJACENT TO THE SEAL ON THE COVER
SHEET.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE BE VERIFIED ON ANY ELECTRONIC
COPIES.
/5
/2
4:
:0
PM
Pl ot
D at e:
STATE OF
NO. 60024
J A
RED ROY BROW
N
P
RO
FESS I ONA L ENG I N
EE
R
L I CENSE
F L O R I D A
PROJECT NO.
LA
ST
S
AV
ED
B
Y:
FILE NAME:
MNT
MNT
JRB
00C09
GENERAL
ALIGNMENT D 27+00_TO_32+50
20203210-001_PP.dwg
M ic ha el
.T is eo
71261.10
ALL "FUTURE" UTILITIES REFERENCES ON THESE PLANS ARE CURRENTLY UNDER DESIGN.
24" DIIQ - DIP
24" DIIQ - DIP
32+50 33+00 33+50 34+00 34+50 35+00 35+50 36+00 36+50 37+00 37+50 38+00
36" DIIQ - HDPE DR11
24" DIIQ - DIP
24" DIIQ - DIP
FUTURE 3" PW
(BY OTHERS)
FUTURE 15" RCP
(BY OTHERS)
FUTURE 8" IRG
(BY OTHERS)
FUTURE 4" RS
(BY OTHERS)
FUTURE 20" IRG
(BY OTHERS)
24" DIIQ - CAP
36"X24" DIIQ - TEE
24" DIIQ - GATE VALVE
24" DIIQ - GATE VALVE
24" DIIQ - TEE
REMOVE 24" CAP
& CONNECT TO
24" WELL PIPING
FUTURE 60" RCP
(BY OTHERS)
FUTURE 60" RCP
(BY OTHERS)
24" DIIQ - GATE VALVE
FUTURE 30" ROC
(BY OTHERS)
FUTURE 24" DUCTBANK
(BY OTHERS)
FUTURE 6" PWL
(BY OTHERS)
FUTURE 8" IRG
(BY OTHERS)
24" DIIQ - 45° VERT BEND
24" DIIQ - 45° VERT BEND
REMOVE 24" CAP
& CONNECT TO
24" WELL PIPING
24" DIIQ - 45° VERT BEND
24" DIIQ - 45° VERT BEND
ABOVE GROUND
WELL PIPING
SEE SHEET 23 & 24
ABOVE GROUND
WELL PIPING
SEE SHEET 23 & 24
36"X24" DIIQ - REDUCER
24" DIIQ - GATE VALVE
Hor. Scale: 1" = 20', Vert. Scale: 1" = 2'Alignment D Sta: 32+50 to Sta: 38+00
32+50 33+00 33+50 34+00 34+50 35+00 35+50 36+00 36+50 37+00 37+50 38+00
PROPOSED
FINISHED GRADE
(BY OTHERS)
3.
0'
M
IN
D
EP
TH
3.
0'
M
IN
D
EP
TH
2.0'
36" DIIQ - HDPE DR11
FUTURE 3" PW
(BY OTHERS)
FUTURE 15" RCP
(BY OTHERS)
FUTURE 60" RCP
(BY OTHERS)
24" DIIQ - TEE
36"X24" DIIQ - REDUCER
36" DIIQ - HDPE DR11
36"X24" DIIQ - TEE 24" DIIQ - DIP
24" DIIQ - GATE VALVE
M
AT
C H
LI
N
E
SE
E
SH
EE
T
DEEP INJECTION
WELL #2
DEEP INJECTION
WELL #1
ELEVATIONS SHOWN HEREON ARE BASED ON NORTH AMERICAN VERTICAL DATUM 1988 (NAVD '88).
CONVERSION FACTOR TO NATIONAL GEODETIC VERTICAL DATUM 1929 (NGVD '29) IS (+) 1.257
JOHNSON ENGINEERING, LLC.
2122 JOHNSON STREET
FORT MYERS, FLORIDA 33901
PHONE: (239) 334-0046
E.R. #642 & L.B. #642DATEREV BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
SHEET NO.
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
301 North Cattlemen Road, Suite 302 Sarasota, FL 34232
Phone: 941-371-9832 CA No. 00008571
THIS DOCUMENT HAS BEEN DIGITALLY SIGNED
AND SEALED BY JARED ROY BROWN, PE ON THE
DATE ADJACENT TO THE SEAL ON THE COVER
SHEET.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE BE VERIFIED ON ANY ELECTRONIC
COPIES.
/5
/2
4:
:3
PM
Pl ot
D at e:
STATE OF
NO. 60024
J A
RED ROY BROW
N
P
RO
FESS I ONA L ENG I N
EE
R
L I CENSE
F L O R I D A
PROJECT NO.
LA
ST
S
AV
ED
B
Y:
FILE NAME:
MNT
MNT
JRB
00C10
GENERAL
ALIGNMENT D 32+50_TO_38+00
20203210-001_PP.dwg
M ic ha el
.T is eo
71261.10
FOR WELL CONNECTION PROFILES
SEE SHEET 18
ALL "FUTURE" UTILITIES REFERENCES ON THESE PLANS ARE CURRENTLY UNDER DESIGN.
Hor. Scale: 1" = 20', Vert. Scale: 1" = 2'Alignment E Sta: 0+00 to Sta: 1+50
0+00 0+50 1+00 1+50
FUTURE 8" IRG
(BY OTHERS)FUTURE 6" PWL
(BY OTHERS)
FUTURE 4" RS
(BY OTHERS)
FUTURE 20" IRG
(BY OTHERS)
DEFLECT FUTURE 6" MAIN
TO AVOID 24" DIIQ
FUTURE 30" ROC
(BY OTHERS) PROPOSED
WELL PAD
(BY OTHERS)
ABOVE GROUND
WELL PIPING
SEE SHEET 23 & 24
REMOVE 24" CAP
& CONNECT TO
24" WELL PIPING
24" DIIQ - 45° VERT BEND
24" DIIQ - DIP
24" DIIQ - 45° VERT BEND
24" DIIQ - GATE VALVE
24" DIIQ - TEE
24" DIIQ - GATE VALVE
24" DIIQ - CAP
24" DIIQ - DIP
24" DIIQ - DIP
0+
0+
1+
1+
0+
1+
1+
36" DIIQ - HDPE DR11
24" DIIQ - DIP
24" DIIQ - DIP
FUTURE 8" IRG
(BY OTHERS)
FUTURE 4" RS
(BY OTHERS)
FUTURE 20" IRG
(BY OTHERS)
24" DIIQ - CAP
36"X24" DIIQ - TEE
24" DIIQ - GATE VALVE
24" DIIQ - GATE VALVE
24" DIIQ - TEE
REMOVE 24" CAP
& CONNECT TO
24" WELL PIPING
FUTURE 60" RCP
(BY OTHERS)
FUTURE 60" RCP
(BY OTHERS)
24" DIIQ - GATE VALVE
FUTURE 30" ROC
(BY OTHERS)
FUTURE 24" DUCTBANK
(BY OTHERS)
FUTURE 6" PWL
(BY OTHERS)
FUTURE 8" IRG
(BY OTHERS)
24" DIIQ - 45° VERT BEND
24" DIIQ - 45° VERT BEND
REMOVE 24" CAP
& CONNECT TO
24" WELL PIPING
24" DIIQ - 45° VERT BEND
24" DIIQ - 45° VERT BEND
ABOVE GROUND
WELL PIPING
SEE SHEET 23 & 24
ABOVE GROUND
WELL PIPING
SEE SHEET 23 & 24
36"X24" DIIQ - REDUCER
24" DIIQ - GATE VALVE
Hor. Scale: 1" = 20', Vert. Scale: 1" = 2'Alignment F Sta: 0+00 to Sta: 1+50
0+00 0+50 1+00 1+50
ABOVE GROUND
WELL PIPING
SEE SHEET 23 & 24
REMOVE 24" CAP
& CONNECT TO
24" WELL PIPING
24" DIIQ - 45° VERT BEND
24" DIIQ - 45° VERT BEND
24" DIIQ - GATE VALVE
36"X24" DIIQ - TEE
24" DIIQ - DIP
24" DIIQ - DIP
PROPOSED
WELL PAD
(BY OTHERS)
FO
R
C O
N
TI
N U
AT
IO
N S
EE
S
H
EE
T
ALIGNMENT E
DEEP INJECTION
WELL #2
DEEP INJECTION
WELL #1
ELEVATIONS SHOWN HEREON ARE BASED ON NORTH AMERICAN VERTICAL DATUM 1988 (NAVD '88).
CONVERSION FACTOR TO NATIONAL GEODETIC VERTICAL DATUM 1929 (NGVD '29) IS (+) 1.257
JOHNSON ENGINEERING, LLC.
2122 JOHNSON STREET
FORT MYERS, FLORIDA 33901
PHONE: (239) 334-0046
E.R. #642 & L.B. #642DATEREV BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
SHEET NO.
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
301 North Cattlemen Road, Suite 302 Sarasota, FL 34232
Phone: 941-371-9832 CA No. 00008571
THIS DOCUMENT HAS BEEN DIGITALLY SIGNED
AND SEALED BY JARED ROY BROWN, PE ON THE
DATE ADJACENT TO THE SEAL ON THE COVER
SHEET.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE BE VERIFIED ON ANY ELECTRONIC
COPIES.
/5
/2
4:
:0
PM
Pl ot
D at e:
STATE OF
NO. 60024
J A
RED ROY BROW
N
P
RO
FESS I ONA L ENG I N
EE
R
L I CENSE
F L O R I D A
PROJECT NO.
LA
ST
S
AV
ED
B
Y:
FILE NAME:
MNT
MNT
JRB
00C11
GENERAL
WELL SITE ALIGNEMNTS E & F
20203210-001_PP.dwg
M ic ha el
.T is eo
71261.10
ALIGNMENT F
ALL "FUTURE" UTILITIES REFERENCES ON THESE PLANS ARE CURRENTLY UNDER DESIGN.
REFERENCE TO SAID UTILITIES ARE FOR INFORMATION PURPOSES ONLY.
MONITORING WELL
GRADE9'-0"
6"
6'-0"4'GRADE
16"x10" ECC
REDUCER
(2) 10" GVS
16"x10" ECC REDUCER
10" TEE
10" TEE
16" 90° MJ BEND
16" PIPE
10" ENDRESS+HAUSER
PROMAG FLOW METER
4'-2"
REMOVE EX. 16" 90° BEND
AND INSTALL 16" TEE
2' -6
1'-8"
5'-10"
16" PIPE
16" 90° BEND
16" 90° MJ BEND
16" PIPE
PIPE STANCHION
(TYP.)
PIPE SUPPORT (TYP.)
REINFORCED CONCRETE
SLAB 7'-6" x 9'-0" x 6" THICK
1/2" Ø GR316 S.S. ANCHOR HDW
PROVIDE 14" RAM-NECK
SEALANT BETWEEN CONC.
AND PIPE
1/4" THICK x 4" WIDE ANODIZED
ALUMINUM STRAP ANCHORED TO
SUPPORT…