26_61301_001 Complete Bid Package_Golf Course.pdf

PDF 16 MB Posted

Attached to
26-61301-001 Irrigation Materials for Uncle Remus Golf Course
Solicitation number
PE-77002-NONST-2026-000000011
Issued by
Polk County, Georgia

About this file

This is a complete bid package document for Putnam County, Georgia, solicitation 26-61301-001 for irrigation materials and equipment required for a new irrigation system at Uncle Remus Golf Course. The project encompasses the supply of materials necessary to install a comprehensive irrigation system at the golf course facility. Sealed bids are requested and must be submitted using the official proposal form provided in the bid package. Proposals must be received by Thursday, September 10, 2026, at 3:00 p.m., at which time proposals will be publicly read. Bids are valid for 60 business days from submission. The bid package is available through the Putnam County Board of Commissioners via the county website at www.putnamcountyga.us/rfps.

Putnam County reserves the right to reject any and all bids, waive any technicalities, and award the contract based on the lowest bid and/or the best interest of the county. The solicitation encourages minority-owned, locally-owned, women-owned, and women-operated businesses to submit proposals. Specific pricing terms, material specifications, quantities, and detailed technical requirements are contained within the complete bid package documentation. No incumbent information, site visit requirements, or pre-bid conference details are specified in the solicitation notice provided.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SOLICITATION

26-61301-001

Irrigation Materials For Uncle Remus Golf Course

Putnam County Board of Commissioners 117 Putnam Drive, Suite A

Eatonton, GA 31024

September 10, 2026

3:00 P.M.

PUTNAM COUNTY BOARD OF COMMISSIONERS

117 Putnam Drive, Suite A ◊ Eatonton, GA 31024

Tel: 706-485-5826 ◊ www.putnamcountyga.us

PUTNAM COUNTY

SOLICITATION # 26-61301-001

Irrigation Materials For Uncle Remus Golf Course

The Putnam County Board of Commissioners requests sealed bids, good for 60 business days, for materials for a new irrigation system at Uncle

Remus Golf Course.

Prospective bidders must obtain a bid package from the Putnam County Board of Commissioners via the county website:

www.putnamcountyga.us/rfps

Proposals must be submitted on the proposal form issued by Putnam County and contained in the bid package.

Proposals must be received by Thursday, September 10, 2026 at 3:00 p.m. The proposals will be read at that time.

LOCAL AND MINORITY OWNED/OPERATED AND/OR WOMEN

OWNED/OPERATED BUSINESSES ARE ENCOURAGED TO SUBMIT PROPOSALS.

PUTNAM COUNTY RESERVES THE RIGHT TO REJECT ANY AND ALL BIDS, TO

WAIVE ANY AND ALL TECHNICALITIES AND TO AWARD THE BID BASED ON

THE LOWEST AND/OR BEST INTEREST OF PUTNAM COUNTY.

08/06/2026 & 08/13/2026 & 08/20/2026 & 08/27/2026 http://www.putnamcountyga.us/

Putnam County BOC Page 1 of 7 Instructions

INSTRUCTIONS AND SPECIFICATIONS FOR BIDDERS:

SOLICITATION # 26-61301-001

IRRIGATION MATERIALS FOR UNCLE REMUS GOLF COURSE

PUTNAM COUNTY, GEORGIA

SECTION 1 – GENERAL NOTICE

Sealed proposals for materials for a new irrigation system at Uncle Remus Golf Course

(SOLICITATION: 26-61301-001) will be received by the office of the Board of Commissioners of Putnam County, Georgia, up to the hour of 3:00 P.M. local time, on Thursday, September 10, 2026, at which time and place they will be publicly opened and read aloud. Bidders are invited to be present.

SECTION 2 – BID DOCUMENTS

Copies of the Proposal, Specifications, Plans (if required) and other document forms may be obtained from the office of the County Commissioners. Bidders are required to examine the same and satisfy themselves that all requirements are fully understood. It is highly recommended that bidders also personally inspect the location of the project upon which they are bidding.

SECTION 3 – BIDDING PROCEDURE

Bids shall be presented in a sealed envelope with the bid number (26-61301-001) and the name of the company or firm submitting clearly marked on the outside of the envelope. IF SUBMITTING

A PHYSICAL BID, TWO PAPER COPIES AND ONE ELECTRONIC COPY MUST BE SUBMITTED. IF

SUBMITTING ELECTRONICALLY, ONE ELECTRONIC COPY MAY BE SUBMITTED VIA THE COUNTY

WEBSITE. Bids will not be accepted verbally, by fax or email. All appropriate blanks shall be completed. Any interlineations, alteration, or erasure on the specification document shall be initialed by the signer of the bid. Bidder shall not change the proposal form nor make additional stipulations on the specification document. Any amplified or qualifying information shall be on the bidder’s letterhead and firmly attached to the bid document. Items in RED are requirements for bid consideration.

Bid prices shall be submitted on the Proposal Form included in the bid document.

Putnam County BOC Page 2 of 7 Instructions

Each bid must be legibly printed in ink or by printer, include the full name, business address, and telephone number of the bidder and be signed in ink by the bidder.

A bid by a firm or organization other than a corporation must include the name and address of each member.

A bid by a corporation must be signed in the name of such corporation by a duly authorized official thereof.

No bidder shall submit more than one proposal nor submit two or more proposals under different names.

In order to be considered, the outside of the sealed envelope must be clearly marked with the offeror’s name, address and phone number, the project number, name of the project for which the proposal is being submitted, and the bid opening date and time of Thursday, September 10, 2026 at 3:00 p.m. All proposals shall be delivered by a delivery service or in person to Putnam County Board of Commissioners, Attn: County Clerk, 117 Putnam Drive, Suite A, Eatonton, GA 31024, or submitted electronically, on or before the time and date prescribed above.

For your convenience, please use the label on the enclosed “Submittal Requirement” page.

Bids received after the time and date established for receiving bids will be rejected.

SECTION 4 – QUALIFICATION OF BIDDERS

All bidders shall provide a Work Resume and file it with their bid. The resume shall include projects which are similar to the type of work being bid for which the bidder had direct control over and was charged with full responsibility of the outcome.

SECTION 5 – ADDENDA

Addenda are written instruments issued by the County prior to the date for receipt of bids which modify or interpret the specification document by addition, deletion, clarification, or correction.

Addenda will be mailed or delivered to all who are known by the County to have received a complete set of specification documents. Potential bidders may return the “Potential Bidder Form” to ensure they are notified of any addenda issued.

Copies of addenda will be posted on the county website and will also be available for inspection at the office of the County Clerk.

No addendum will be issued later than forty-eight (48) hours prior to the date and time for receipt of bids, except an addendum withdrawing the invitation to bid or an addendum which includes postponement of the bid.

Putnam County BOC Page 3 of 7 Instructions

Bidders shall ascertain prior to submitting their bid that they have received all addenda issued and they shall acknowledge receipt of addenda on the proposal form.

SECTION 6 – BIDDER’S REPRESENTATION

Each bidder by signing and submitting a bid, represents that the bidder has read and understands the specification documents and the bid has been made in accordance therewith.

Each bidder for services further represents that the bidder is familiar with the local conditions under which the work is to be done and has correlated the observations with the requirements of the bid documents.

NON-COLLUSION AFFIDAVIT: By submitting a proposal, the bidder represents and warrants that such bid is genuine and not a sham or collusion or made in the interest or in behalf of any person not therein named, and that the bidder has not directly or indirectly induced or solicited any other bidder to put in a sham bid, or any other firm, person or corporation to refrain from bidding and that the bidder has not in any manner sought by collusion to secure to that bidder any advantage over any other bidder.

INTEREST OF: By submitting a proposal, the bidder represents and warrants that neither a commissioner, administrator, manager, employee, nor any other person employed by PUTNAM COUNTY or in any other way connected with the county has, in any manner, an interest, either directly or indirectly, in the bid or in the contract which may be made under it, or in any expected profits to arise therefrom.

CERTIFICATE OF INDEPENDENT PRICE DETERMINATION: By signing and submitting this bid, the bidder certifies that the prices in this bid have been arrived at independently, without consultation, communication, or agreement, for the purpose of restricting competition, as to any matter relating to such prices with any other bidder or with any competitor; unless otherwise required by law, the prices which have been quoted in this bid have not been knowingly disclosed by the bidder prior to bid opening directly or indirectly to any other bidder or to any competitor;

no attempt has been made, or will be made, by the bidder to induce any person or firm to submit, or not to submit, a bid for the purpose of restricting competition.

Various professions within the building industry are required by state law to be licensed. These professions include electricians, plumbers, conditioned air contractors, low voltage contractors, utility contractors, and certain residential and general contractors. Putnam County will be complying with state laws and board rules regarding licensure. No bid or proposal for projects that require a licensed professional will be accepted from unlicensed persons. In addition, the licensed contractor must be the prime contractor on the project. It is not permissible for an unlicensed individual/firm to subcontract with a licensed contractor. The validity of all licenses will be checked.

SECTION 7 – BIDDER’S SECURITY

BID BOND: Not required.

Putnam County BOC Page 4 of 7 Instructions

PERFORMANCE BOND: Not required.

SECTION 8 – EQUAL OPPORTUNITY

Each bidder agrees that it shall not discriminate against any employee or applicant for employment because of race, color, religion, sex, disability, national origin, age, or marital status.

In the employment of persons, bidder shall take affirmative action to ensure that applicants are employed and that employees are treated during employment without regard to race, color, religion, sex, disability, national origin, age, or marital status.

SECTION 9 – CLARIFICATION OF SPECIFICATION DOCUMENTS

Bidders shall promptly notify the County Clerk of any ambiguity, inconsistency, or error which they may discover upon examination of the specification documents.

Bidders desiring clarification or interpretation of the Specification documents shall make a written request which must reach the County Clerk at least seven (7) calendar days prior to the date and time for receipt of bids.

Interpretations, corrections, and changes made to the Specification Documents will be made by written addenda. Oral interpretations or changes to the Specification Documents made in any other manner, will not be binding on the County; and bidders shall not rely upon such interpretations or changes.

SECTION 10 – SCHEDULE

The project shall be Substantially Complete within 120 calendar days from the date of issuance of Notice to Proceed. Liquidated damages of $1,500 per day will be assessed if work is not completed within 120 calendar days (excluding weather delays) from the date of the Notice to Proceed. Uncle Remus Golf Course is located at 120 Hambone Holle Drive, Eatonton, GA 31024.

SECTION 11 – BID EVALUATION AND AWARD

The signed bid proposal shall be considered an offer on the part of the bidder. Such offer shall be deemed accepted upon issuance, by the County, of purchase orders, contract award notifications, or other contract documents appropriate to the work.

No bid shall be modified or withdrawn for a period of sixty (60) calendar days after the time and date established for receiving bids and each bidder so agrees in submitting the bid.

Award will be made to the vendor submitting the lowest responsive and responsible bid. The Putnam County Board of Commissioners reserves the right to reject any or all bids, to waive technicalities and to re-advertise or make an award as deemed in its best interest. The written bid documents supersede any verbal or written prior communication between the parties.

Putnam County BOC Page 5 of 7 Instructions

SECTION 12 – CONTRACT AND BOND

After the acceptance of the bid, the successful bidder must execute a written Contract between the bidder and the County; such contract will incorporate the County’s contract documents and be on forms provided by the County.

SECTION 13 – INSURANCE

All bidders shall take special note of the attached insurance sheet titled “Insurance Clause for all County Contracts.”

The successful bidder must provide proof of insurance in accordance with the contract documents.

SECTION 14 – INDEMNIFICATION

The bidder shall indemnify and hold harmless the County, its members, its officers, and employees from and against all claims, damages, losses, and expenses, including, but not limited to attorney’s fees arising out of or resulting from the performance of the contract, provided that any such claim, damage, loss, or expense is attributable to bodily injury, sickness, disease, or death, or to injury to or destruction of tangible property other than goods, materials, and equipment furnished under this contract, including the loss of use resulting therefrom; is caused in whole or part by any negligent act or omission of the bidder, any subcontractor, or anyone directly or indirectly employed by any one of them or anyone for whose acts made by any of them may be liable, regardless of whether or not it is caused by a party indemnified hereunder.

In any and all claims against the County or its members, officers or employees by an employee of the bidder, any subcontractor, anyone directly or indirectly employed by any of them or by anyone for whose acts made by any of them may be liable, the indemnification obligation listed above shall not be limited in anyway by any limitation of the amount or type of damages, compensation, or benefits payable by or for the bidder or any subcontractor under worker’s or workmen’s compensation acts, disability benefit acts, or other employee benefit acts.

SECTION 15 – LAWS

The Laws of the State of Georgia shall govern the rights, obligations, and remedies of the Parties under this proposal and any agreement reached as a result of this process.

SECTION 16 – INDEPENDENT CONTRACTOR

It is the express intent of the parties that this Contract shall not create an employer-employee relationship, and the Contractor, or any employee or other person acting on behalf of Contractor in the performance of this Contract, shall be deemed to be independent contractor(s) during the entire term of this Contract or any renewals thereof. Contractor shall be responsible for all compensation and benefits payable to Contractor’s employee(s) under this Contract and Contractor’s employees shall not be entitled to any compensation from County or to any benefits made to their employees, including, but not limited to, overtime, vacation, retirement benefits, Putnam County BOC Page 6 of 7 Instructions workers’ compensation, sick leave, or injury leave. Contractor shall also be responsible for maintaining workers’ compensation insurance, unemployment insurance, and for payment of all federal, state, local and any other payroll taxes with respect to the employee’s compensation.

SECTION 17 – CERTIFICATION

By signing and submitting a proposal, the bidder certifies that they have carefully examined the plans for this project and the applicable federal, state, and local regulations and the special provisions included in and made a part of this proposal, and have also personally examined the site of the work. If awarded, the bidder further proposes to execute the contract agreement described in the specifications as soon as the work is awarded.

SECTION 18 - DRUG-FREE WORK PLACE CERTIFICATION

By signing and submitting a proposal, the bidder certifies that the provisions of Code Sections 50- 24-1 through 50-24-6 of the Official Code of Georgia Annotated, relating to the "Drug-free Work Place Act”, have been complied with in full. The bidder further certifies that:

(1) A drug-free work place will be provided for the contractor's employees during the performance of the contract; and

(2) Each contractor who hires a subcontractor to work in a drug-free work place shall secure from that subcontractor a written certification that a drug free work place will be provided for the subcontractor's employees during the performance of this contract pursuant to paragraph (7) of subsection (b) of Code Section 50-24-3.

Also, they further certify that they will not engage in the unlawful manufacture, sale, distribution, dispensation, possession, or use of a controlled substance or marijuana during the performance of the contract.

SECTION 19 – SECURITY AND IMMIGRATION COMPLIANCE

It is further certified that pursuant to O.C.G.A. §13-10-91 I and all contractors and sub-contractors performing work under this Agreement are in compliance with the Federal Work Authorization Program. Prime contractors and sub-contractors may participate in any of the electronic verification of work authorization programs operated by the United States Department of Homeland Security or any equivalent federal work authorization program operated by the United States Department of Homeland Security to verify information of newly hired employees, pursuant to the Immigration Reform and Control Act of 1986 (“IRCA”). Contractor Affidavit, Subcontractor Affidavit (if applicable), and Sub-subcontractor Affidavit (if applicable) must be completed and turned in with your bid.

It is further certified that pursuant to O.C.G.A. §50-36-1 I am a United States citizen, a legal permanent resident of the United States, or a qualified alien or non-immigrant under the Federal Immigration and Nationality Act with an alien number issued by the Department of Homeland Security or other federal immigration agency. Affidavit must be completed and turned in with your bid, along with a copy of your driver’s license.

Putnam County BOC Page 7 of 7 Instructions

SECTION 20 – PAYMENTS

Contractor shall be paid by and in accordance with Putnam County payment regulations. Putnam County will strive to take advantage of all discounts offered for prompt payment, therefore, indicate all discounts on monthly invoices. Invoices shall not be submitted more frequently than once a month.

SECTION 21 – SPECIFICATIONS

See plans identified as “IRRIGATION SYSTEM DESIGN FOR UNCLE REMUS GOLF COURSE.”

See specifications identified as “IRRIGATION PROJECT SPCIFICATIONS – MATERIALS.”

For additional information, please contact Uncle Remus Golf Course Director Michael Benton at

(706) 485-6850 or mbenton@putnamcountyga.us.

Member

The Irrigation Association

THIS DESIGN DRAWING IS THE PROPERTY

OF JAS IRRIGATION CONSULTING, LLC.,

DUPLICATION THEREOF IS PROHIBITED.

ANY UNAUTHORIZED USE, ALTERATION OR

004331

JAS Irrigation Consulting, LLC

WHERE WISE USE OF WATER STARTS

TABLE OF CONTENTS

COVER

IR-01 - HYDRAULIC

IR-02 - ELECTRICAL - HUNTER/TORO

IR-03 - ELECTRICAL LAYOUT - RAIN BIRD

IR-04 - DETAILS

IR-05 - DETAILS

IRRIGATION SYSTEM DESIGN FOR

120 HAMBONE HOLLE DR

EATONTON, GA 31024

RELEASED FOR BID 3/31/26

PG

6'

6'

6'

6''

6''

6''

6''

6'' 6''

6'' 6'' 6'' 6'' 6'' 6'' 6''

6'

6'

6'

6''

6'

6'

6'

6'

6''

6'

6'

6''

6'

6'

6'' 6''

6''

6''

6''

6''

6'' 6''

8'' 8'' 8'' 8''

8''

8''

8''

8''

8''

8''

8''

8''

6''

6''

6'' 6''

6''

6''

6''

6'' 6''

6'' 6'' 6'' 6'' 6'' 6''

6'' 6''

6'' 6''

6'' 6'' 6''

6'' 6''

6'' 6''

6'' 6''

6'' 6''

6''

6'' 6''

6'' 6''

6'' 6''

6''

6''

6''

6''6'

6'

6'

6'

6''

6'

6'

6'

6'

6'

6'

6'

6'

6'

6''

6''

6'

6'

6'

4''

4'

6'

6'

6'' 6''

4''

4''

4''

6''

6''

6''

6''

6''

6''

6'' 6''

6''

6'' 6''

6'' 6''

6'' 6''

6'' 6''

6''

6''

6''

6''

6''

6''

6''

6'

6'

6'

6''

6'

6'' 6'' 6'' 6''

6'' 6'' 6''

6''

6''

6''

6'

6'

6'

6'

6'

6''

6''

6'

6''

F18

F12 F13

3'' 3''

3''

3'' 3'

3''

3'

3'

3''

4''

4''

3'

3''

4''

3''

4''

4''

4''

3''

3''

3''

D

D

D

D

D

C

PWR

4"

4"

4"

4"

4"

4" 4"

4"

4"

4"

4" D

TIE IN TO MUNI POC

FOR PONDFILL

DateRevision/IssueNo.

Project Name and Address

SheetProject

Checked by:Drawn by:

Scale 1" = 100'-0"

Date

Member

The Irrigation Association

THIS DESIGN DRAWING IS THE PROPERTY

OF JAS IRRIGATION CONSULTING, LLC.,

DUPLICATION THEREOF IS PROHIBITED.

ANY UNAUTHORIZED USE, ALTERATION OR

IR-01

3/12/26

UNCLE REMUS GOLF COURSE

120 HAMBONE HOLLE DR

EATONTON, GA 31024

UNCLEREMUSGC2026

004331

JAS Irrigation Consulting, LLC

WHERE WISE USE OF WATER STARTS

JAS JAS

SPRINKLER LEGEND

KEY DESCRIPTION GPM SPC PSI

18.6 35-50'

43.6 75'

HUNTER MODEL GT885D SPRINKLER - #18 ORANGE NOZZLE

HUNTER MODEL GT880D SPRINKLER - #43 DK BROWN NOZZLE

8075'HUNTER MODEL GT885D SPRINKLER - #43 DK BROWN NOZZLE 43.5

IRRIGATION SYSTEM INSTALLATION NOTES:

1) ALL MAINLINE PIPING TO BE DR11 HDPE

2) ALL LATERAL PIPING TO BE DR13.5 HDPE

3) ALL LATERAL PIPE IS TO BE 2" UNLESS OTHERWISE NOTED.

4) ALL GREENS FEEDS ARE TO BE 4" TYPICAL

5) NO PIPING SHALL BE INSTALLED WITHIN THE CONFINES OF A GREEN, TEE

OR A SAND BUNKER.

6) ALL PIPE 3" AND LARGER SHALL BE INSTALLED TO PROVIDE 30" COVER

FROM THE TOP OF THE PIPE TO FINISH GRADE. ALL PIPE 2.5" AND SMALLER

SHALL BE INSTALLED TO PROVIDE A MINIMUM OF 24" COVER FROM TOP OF

PIPE TO FINISH GRADE.

7) ALL VALVES ARE TO BE INSTALLED ACCORDING TO MANUFACTURER RECOMMENDATIONS,

IN A VALVE BOX WITH THE APPROPRIATE SLEEVE.

8) ALL SPRINKLERS, QUICK COUPLERS AND VALVE BOX LOCATIONS ARE TO BE APPROVED

BY THE OWNERS REPRESENTATIVE PRIOR TO INSTALLATION.

9) ALL PAVED SURFACES THAT ARE CROSSED BY PIPING AND/OR WIRE MUST BE CUT/BORED AND PATCHED TO OWNERS SPECIFICATION. ALL PIPE AND WIRE MUST BE INSTALLED THROUGH SLEEVING TWO SIZES LARGER THAN PIPE WITH WIRE BEING INSTALLED IN SEPARATE HDPE SLEEVE AT LEAST 2" PER WIRE RUN PASSING THROUGH, IN DIAMETER.

9) DRAIN VALVES AND AIR RELIEF VALVE LOCATIONS TO BE DETERMINED IN FIELD IF NOT DEMARCATED ON PLAN.

10) THE CONTRACTOR IS RESPONSIBLE FOR THEIR OWN SITE VISITS TO EXAMINE WORKING CONDITIONS.

THE CONTRACTOR IS ALSO RESPONSIBLE FOR THEIR OWN MATERIAL TAKE-OFF AND MEASUREMENTS. ALL CHNAGES

SHOULD BE SUBMITTED IN WRITING PRIOR TO BEGIN OF WORK.

11) THE CONTRACTOR MUST NOTIFY THE IRRIGATION CONSULTANT PRIOR TO ANY

SIGNIFICANT CHANGES TO THE MAINLINE ROUTING. NO PIPING MAY BE SUBSTITUTED WITH

SMALLER PIPE. THE CONTRACTOR MUST RECEIVE WRITTEN APPROVAL BY THE IRRIGATION CONSULTANT BEFORE

DEVIATING FROM ORIGINAL DESIGN.

12) THE IRRIGATION SYSTEM HAS BEEN DESIGNED FOR EFFICIENT AND OPTIMAL PERFORMANCE.

ANY DEVIATION WITHOUT EXPRESS WRITTEN APPROVAL BY BY THE IRRIGATION CONSULTANT IS STRICTLY PROHIBITED. THE CONTRACTOR WILL BE HELD SOLELY RESPONSIBLE FOR ALL DAMAGES AND/OR SYSTEM PERFORMANCE ISSUES CAUSED BY DEVIATIONS, IF DEVIATIONS ARE NOT APPROVED IN WRITING PRIOR TO

INSTALLATION.

8031.7 65'HUNTER MODEL GT880D SPRINKLER - #25 BLUE NOZZLE

8065'HUNTER MODEL GT885D SPRINKLER - #25 BLUE NOZZLE 31.5

HYDRAULIC LEGEND

KEY DESCRIPTION

4" GATE VALVE W/HDPE ENDS - AVK / CLOW

6" GATE VALVE W/HDPE ENDS- AVK / CLOW

DRAIN VALVE ASSY: 2" ELECTRIC VALVE W/ 2" POLY VALVE W/ TWM/ ICM / LSM

2" COMBINATION VACUUM / AIR RELEASE VALVE

2" DR 13.5 HDPE LATERAL PIPE

3" DR 13.5 HDPE LATERAL PIPE

4" DR 11 HDPE MAINLINE PIPE

6" DR 11 HDPE MAINLINE PIPE

3" 360 DEGREE KIS/AQUAFUSE POLY BALL VALVE

18.8

36.3 75'

RAIN BIRD MODEL 752IC SPRINKLER - #28 WHITE NOZZLE

RAIN BIRD MODEL 952IC SPRINKLER - #52 ORANGE NOZZLE

8075'RAIN BIRD MODEL 952IC SPRINKLER - #26 ORANGE NOZZLE 36.3

8" DR 11 HDPE MAINLINE PIPE

8030.6 65'RAIN BIRD MODEL 702IC SPRINKLER - #40 ORANGE NOZZLE

8065'RAIN BIRD MODEL 752IC SPRINKLER - #40 ORANGE NOZZLE 30.6

15.9

52.9 75'

TORO MODEL INF35 SPRINKLER - #31 ORANGE NOZZLE

TORO MODEL INF54 SPRINKLER - #57 BLACK NOZZLE

8075'TORO MODEL INF55 SPRINKLER - #57 BLACK NOZZLE 42.9

8028.5 65'TORO MODEL INF34 SPRINKLER - #33 BROWN NOZZLE

8065'TORO MODEL INF35 SPRINKLER - #34 ORANGE NOZZLE 28.5

DR13.5 HDPE SLEEVE FOR ROAD CROSSINGS (TWO SIZES LARGER THAN THROUGH

-PIPE)

1" QUICK COUPLING VALVE (ACME)

35-50'

35-50'

2" 360 DEGREE KIS/AQUAFUSE POLY BALL VALVE

D

PG

W P1

W P1

W P1

W P1

W P1

W P1

WP1

WP1

WP1

W P1

W P1

W P1

WP1

WP1 WP1 WP1 WP1 WP1 WP1 WP1 WP1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

WP1

WP1

WP1

WP1

W P1

W P1

W P1

W P1

WP1 WP1

WP1

WP1

WP1

WP1 WP1 WP1

WP1

W P1

W P1

W P1

W P1

W P1

W P1

W P2

WP2

WP2

WP2

WP2

WP2

WP2

WP2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

WP2 WP2 WP2 WP2 WP2 WP2

WP2

WP2

WP2

WP2

WP2

WP2

WP2

WP2

WP2

WP2

WP2

WP2

WP2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

WP2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

WP2

W P2

W P2

W P2

WP1

WP1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

WP1

WP1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

WP1

WP1

WP1 WP1

WP1

WP1

WP1

WP1 WP1

WP1

WP1

WP1

WP1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

F18

F12 F13

D

D

D

D

D C

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

D

CC

G

ELECTRICAL LEGEND

KEY DESCRIPTION

WIRE PATH 1 - 163 STATIONS

CC

PILOT DECODER HUB/ LYNX SMART HUB WITH RADIO

PWR POWER LOCATION - MAIN PUMP STATION AND MAINTENANCE FACILITY

LINE SURGE PROTECTION W/ COPPER GROUND ROD / GROUND PLATE KIT AND

REENTERABLE CONNECTORS

C

CENTRAL COMPUTER - LOCATED AT MAINTENANCE FACILITY W/ GROUNDING

WP1

WIRE PATH 2 - 125 STATIONSWP2

SPRINKLER LEGEND

KEY DESCRIPTION GPM SPC PSI

18.6 35-50'

43.6 75'

HUNTER MODEL GT885D SPRINKLER - #18 ORANGE NOZZLE

HUNTER MODEL GT880D SPRINKLER - #43 DK BROWN NOZZLE

8075'HUNTER MODEL GT885D SPRINKLER - #43 DK BROWN NOZZLE 43.5

8031.7 65'HUNTER MODEL GT880D SPRINKLER - #25 BLUE NOZZLE

8065'HUNTER MODEL GT885D SPRINKLER - #25 BLUE NOZZLE 31.5

15.9

52.9 75'

TORO MODEL INF35 SPRINKLER - #31 ORANGE NOZZLE

TORO MODEL INF54 SPRINKLER - #57 BLACK NOZZLE

8075'TORO MODEL INF55 SPRINKLER - #57 BLACK NOZZLE 42.9

8028.5 65'TORO MODEL INF34 SPRINKLER - #33 BROWN NOZZLE

8065'TORO MODEL INF35 SPRINKLER - #34 ORANGE NOZZLE 28.5

35-50'

DR13.5 HDPE SLEEVE FOR ROAD CROSSINGS (TWO SIZES LARGER THAN THROUGH

-PIPE)

G

IRRIGATION SYSTEM ELECTRICAL INSTALLATION NOTES:

1) NO WIRE SHALL BE INSTALLED WITHIN THE CONFINES OF A GREEN, TEE

OR A SAND BUNKER.

2) ALL WIRE SHALL BE INSTALLED TO PROVIDE A MINIMUM OF 24" COVER FROM TOP OF

PIPE TO FINISH GRADE.

3) ALL VALVES ARE TO BE INSTALLED ACCORDING TO MANUFACTURER RECOMMENDATIONS,

IN A VALVE BOX WITH THE APPROPRIATE SLEEVE.

4) ALL SPRINKLERS, QUICK COUPLERS AND VALVE BOX LOCATIONS ARE TO BE APPROVED

BY THE OWNERS REPRESENTATIVE PRIOR TO INSTALLATION.

5) ALL PAVED SURFACES THAT ARE CROSSED BY PIPING AND/OR WIRE MUST BE CUT/BORED AND PATCHED TO OWNERS SPECIFICATION. ALL PIPE AND WIRE MUST BE INSTALLED THROUGH SLEEVING TWO SIZES LARGER THAN PIPE WITH WIRE BEING INSTALLED IN SEPARATE HDPE SLEEVE AT LEAST 2" PER WIRE RUN PASSING THROUGH, IN DIAMETER.

6) ALL GROUND LOCATIONS TO BE MEASURED FOR RESISTANCE OF 10 OHMS OR LESS AFTER INSTALLATION, REGARDLESS OF MANUFACTURER. INCLUDE THE ADDITION OF ONE EXTRA 4" X 36" GROUND PLATE ASSEMBLY

PER GROUNDING LOCATION AS "ADD ALTERNATE"

7) THE CONTRACTOR IS RESPONSIBLE FOR THEIR OWN SITE VISITS TO EXAMINE WORKING CONDITIONS.

THE CONTRACTOR IS ALSO RESPONSIBLE FOR THEIR OWN MATERIAL TAKE-OFF AND MEASUREMENTS AFTER AWARD OF CONTRACT. QUANTITIES PROVIDED IN SPECIFICATIONS ARE FOR BIDDING PURPOSES ONLY.

8) THE CONTRACTOR MUST NOTIFY THE IRRIGATION CONSULTANT PRIOR TO ANY

SIGNIFICANT CHANGES TO THE WIRE ROUTING. NO WIRE MAY BE SUBSTITUTED WITH

SMALLER WIRE. THE CONTRACTOR MUST RECEIVE WRITTEN APPROVAL BY THE IRRIGATION CONSULTANT BEFORE

DEVIATING FROM ORIGINAL DESIGN.

9) THE IRRIGATION SYSTEM HAS BEEN DESIGNED FOR EFFICIENT AND OPTIMAL PERFORMANCE.

ANY DEVIATION WITHOUT EXPRESS WRITTEN APPROVAL BY BY THE IRRIGATION CONSULTANT IS STRICTLY PROHIBITED. THE CONTRACTOR WILL BE HELD SOLELY RESPONSIBLE FOR ALL DAMAGES AND/OR SYSTEM PERFORMANCE ISSUES CAUSED BY DEVIATIONS, IF DEVIATIONS ARE NOT APPROVED IN WRITING PRIOR TO

INSTALLATION.

WIRE SCHEDULE:

1) ALL TRUNKLINE WIRE TO BE 12/2 , ALL LATERAL WIRE TO BE 14/2

2) 14/2 LATERAL WIRE TO FAIRWAYS TO BE YELLOW JACKETED

3) 14/2 LATERAL WIRE TO TEES TO BE PURPLE JACKETED

4) 14/2 LATERAL WIRE TO GREENS TO BE GREEN JACKETED

5) 14/2 LATERAL WIRE TO DRAIN VALVES TO BE WHITE JACKETED

6) AT EVERY GROUNDING CONNECTION - A PAIGE REENTERABLE CONNECTION P7408D

FOR EASY ISOLATION AND TESTING OF GROUNDING.

7) EVERY TRUNKLINE TO LATERAL SPLICE WILL HAVE A TAG DENOTING WIRE PATH AND LOCATION USING PAIGE WIRE

MARKING TAG (270WMT) OR EQUIVALENT

8) ALL WIRE SPLICES TO DECODER/LSM/ICM CONNECTIONS TO BE CONNECTED VIA MANUFACTURER'S

RECOMMENDATION WITH DBRY-6 MINIMUM.

9) WIRE LENGTHS PROVIDED ARE FOR BID PURPOSES ONLY. CONTRACTOR/DISTRIBUTOR RESPONSIBLE FOR OWN

TAKE-OFFS AFTER PROJECT AWARD.

DateRevision/IssueNo.

Project Name and Address

SheetProject

Checked by:Drawn by:

Scale 1" = 100'-0"

Date

Member

The Irrigation Association

THIS DESIGN DRAWING IS THE PROPERTY

OF JAS IRRIGATION CONSULTING, LLC.,

DUPLICATION THEREOF IS PROHIBITED.

ANY UNAUTHORIZED USE, ALTERATION OR

IR-02

3/12/26

UNCLE REMUS GOLF COURSE

120 HAMBONE HOLLE DR

EATONTON, GA 31024

UNCLEREMUSGC2026

004331

JAS Irrigation Consulting, LLC

WHERE WISE USE OF WATER STARTS

JAS JAS

PG

W P1

W P1

W P1

W P1

W P1

W P1

WP1

WP1

WP1

W P1

W P1

W P1

WP1

WP1 WP1 WP1 WP1 WP1 WP1 WP1 WP1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

WP1

WP1

WP1

WP1

W P1

W P1

W P1

W P1

WP1 WP1

WP1

WP1

WP1

WP1 WP1 WP1

WP1

W P1

W P1

W P1

W P1

W P1

W P1

W P2

WP2

WP2

WP2

WP2

WP2

WP2

WP2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

WP2 WP2 WP2 WP2 WP2 WP2

WP2

WP2

WP2

WP2

WP2

WP2

WP2

WP2

WP2

WP2

WP2

WP2

WP2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

WP2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

W P2

WP2

W P2

W P2

W P2

WP1

WP1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

WP1

WP1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

WP1

WP1

WP1 WP1

WP1

WP1

WP1

WP1 WP1

WP1

WP1

WP1

WP1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

W P1

F18

F12 F13

D

D

D

D

D

C

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

D

CC

G

CC

RAIN BIRD ICI+ WITH RADIO

POWER LOCATION

C

CENTRAL COMPUTER W/RADIO - LOCATED AT MAINTENANCE FACILITY

WITH MGP1 AND MSP1 GROUNDING KITS (SEE DETAILS)

WIRE PATH 2 - 125 STATIONS

IRRIGATION SYSTEM ELECTRICAL INSTALLATION NOTES:

1) NO WIRE SHALL BE INSTALLED WITHIN THE CONFINES OF A GREEN, TEE

OR A SAND BUNKER.

2) ALL WIRE SHALL BE INSTALLED TO PROVIDE A MINIMUM OF 24" COVER FROM TOP OF

PIPE TO FINISH GRADE.

3) ALL VALVES ARE TO BE INSTALLED ACCORDING TO MANUFACTURER RECOMMENDATIONS,

IN A VALVE BOX WITH THE APPROPRIATE SLEEVE.

4) ALL SPRINKLERS, QUICK COUPLERS AND VALVE BOX LOCATIONS ARE TO BE APPROVED

BY THE OWNERS REPRESENTATIVE PRIOR TO INSTALLATION.

5) ALL PAVED SURFACES THAT ARE CROSSED BY PIPING AND/OR WIRE MUST BE CUT/BORED AND PATCHED TO OWNERS SPECIFICATION. ALL PIPE AND WIRE MUST BE INSTALLED THROUGH SLEEVING TWO SIZES LARGER THAN PIPE WITH WIRE BEING INSTALLED IN SEPARATE HDPE SLEEVE AT LEAST 2" PER WIRE RUN PASSING THROUGH, IN DIAMETER.

6) ALL GROUND LOCATIONS TO BE MEASURED FOR RESISTANCE OF 10 OHMS OR LESS AFTER INSTALLATION, REGARDLESS OF MANUFACTURER. INCLUDE THE ADDITION OF ONE EXTRA 4" X 36" GROUND PLATE ASSEMBLY

PER GROUNDING LOCATION AS "ADD ALTERNATE"

7) THE CONTRACTOR IS RESPONSIBLE FOR THEIR OWN SITE VISITS TO EXAMINE WORKING CONDITIONS.

THE CONTRACTOR IS ALSO RESPONSIBLE FOR THEIR OWN MATERIAL TAKE-OFF AND MEASUREMENTS AFTER AWARD OF CONTRACT. QUANTITIES PROVIDED IN SPECIFICATIONS ARE FOR BIDDING PURPOSES ONLY.

8) THE CONTRACTOR MUST NOTIFY THE IRRIGATION CONSULTANT PRIOR TO ANY

SIGNIFICANT CHANGES TO THE WIRE ROUTING. NO WIRE MAY BE SUBSTITUTED WITH

SMALLER WIRE. THE CONTRACTOR MUST RECEIVE WRITTEN APPROVAL BY THE IRRIGATION CONSULTANT BEFORE

DEVIATING FROM ORIGINAL DESIGN.

9) THE IRRIGATION SYSTEM HAS BEEN DESIGNED FOR EFFICIENT AND OPTIMAL PERFORMANCE.

ANY DEVIATION WITHOUT EXPRESS WRITTEN APPROVAL BY BY THE IRRIGATION CONSULTANT IS STRICTLY PROHIBITED. THE CONTRACTOR WILL BE HELD SOLELY RESPONSIBLE FOR ALL DAMAGES AND/OR SYSTEM PERFORMANCE ISSUES CAUSED BY DEVIATIONS, IF DEVIATIONS ARE NOT APPROVED IN WRITING PRIOR TO

INSTALLATION.

SPRINKLER LEGEND

KEY DESCRIPTION GPM SPC PSI

18.8

36.3 75'

RAIN BIRD MODEL 752IC SPRINKLER - #28 WHITE NOZZLE

RAIN BIRD MODEL 952IC SPRINKLER - #52 ORANGE NOZZLE

8075'RAIN BIRD MODEL 952IC SPRINKLER - #26 ORANGE NOZZLE 36.3

8030.6 65'RAIN BIRD MODEL 702IC SPRINKLER - #40 ORANGE NOZZLE

8065'RAIN BIRD MODEL 752IC SPRINKLER - #40 ORANGE NOZZLE 30.6

35-50'

WIRE SCHEDULE:

1) ALL TRUNKLINE WIRE TO BE 12/2 , ALL LATERAL WIRE TO BE 14/2

2) 14/2 LATERAL WIRE TO FAIRWAYS TO BE YELLOW JACKETED

3) 14/2 LATERAL WIRE TO TEES TO BE PURPLE JACKETED

4) 14/2 LATERAL WIRE TO GREENS TO BE GREEN JACKETED

5) 14/2 LATERAL WIRE TO DRAIN VALVES TO BE WHITE JACKETED

6) AT EVERY GROUNDING CONNECTION - A PAIGE REENTERABLE CONNECTION P7408D

FOR EASY ISOLATION AND TESTING OF GROUNDING.

7) EVERY TRUNKLINE TO LATERAL SPLICE WILL HAVE A TAG DENOTING WIRE PATH AND LOCATION USING PAIGE WIRE

MARKING TAG (270WMT) OR EQUIVALENT

8) ALL WIRE SPLICES TO DECODER/LSM/ICM CONNECTIONS TO BE CONNECTED VIA MANUFACTURER'S

RECOMMENDATION WITH DBRY-6 MINIMUM.

9) WIRE LENGTHS PROVIDED ARE FOR BID PURPOSES ONLY. CONTRACTOR/DISTRIBUTOR RESPONSIBLE FOR OWN

TAKE-OFFS AFTER PROJECT AWARD.

ELECTRICAL LEGEND

KEY DESCRIPTION

WIRE PATH 1 - 163 STATIONS

DR13.5 HDPE SLEEVE FOR ROAD CROSSINGS (TWO SIZES LARGER THAN THROUGH

-PIPE)

PWR

G LINE SURGE PROTECTION W/ COPPER GROUND ROD / GROUND PLATE KIT AND

REENTERABLE CONNECTORS

DateRevision/IssueNo.

Project Name and Address

SheetProject

Checked by:Drawn by:

Scale 1" = 100'-0"

Date

Member

The Irrigation Association

THIS DESIGN DRAWING IS THE PROPERTY

OF JAS IRRIGATION CONSULTING, LLC.,

DUPLICATION THEREOF IS PROHIBITED.

ANY UNAUTHORIZED USE, ALTERATION OR

IR-03

3/12/26

UNCLE REMUS GOLF COURSE

120 HAMBONE HOLLE DR

EATONTON, GA 31024

UNCLEREMUSGC2026

004331

JAS Irrigation Consulting, LLC

GATE VALVE

BOX

VALVE

HDPE PIPE

ROAD

20' MIN.

BOX

VALVE

20' MIN.

HDPE PIPE

HDPE PIPE

WATER

STREAM CROSSING

HDPE PIPE

HDPE PIPE

HDPE PIPE

HDPE 45

HDPE 45

HDPE PIPING W/ ELEC. SLEEVING

BRIDGE CROSSING

HDPE PIPE

HDPE PIPE

WATER

CLEVIS HANGERS

PVC ELECTRICAL CONDUIT

ELECTRICAL SLEEVING SHALL BE

HDPE 45

HDPE PIPE

HDPE 45

ACME INLET SWING JOINT ASSEMBLY

END OF LINE OR MAINLINE TAP WITH

1. ACME O-RING SEALED THREADS ARE TO BE FINGER

TIGHTENED AND "BACKED OFF" ONE FULL ROTATION BEFORE

INSTALLATION.

2. THE SWING JOINT LAY ARM IS TO BE INSTALLED AT AN ANGLE

AS PER MANUFACTURES RECOMENDATIONS

TOP VIEW

HDPE LATERAL LINE

END OF LINE

HDPE LATERAL LINE

SWING JOINT INSTALLATION NOTE:

FEMALE ACME OUTLET 90°

ELBOW

FEMALE ACME OUTLET 90°

ELBOW

END OF LINE SERVICE SADDLE

SIDE VIEW

END OF LINE

HDPE LATERAL LINE

END OF LINE

ACME INLET SWING JOINT ASSEMBLY

SADDLE WITH

TOP VIEW

SIDE VIEW

SERVICE SADDLE

HDPE LATERAL LINE

HDPE LATERAL LINE

FUSIBLE HDPE SERVICE

SADDLE

FUSIBLE HDPE SERVICE

SADDLE

HDPE LATERAL LINE

ACME INLET SWING JOINT

FEMALE ACME OUTLET 90°

ELBOW

FEMALE ACME OUTLET 90°

ELBOW

LATERAL SYSTEM DETAIL - 25 YEAR MANUFACTURER WARRANTY REQUIRED

FINISH GRADE

VALVE BOX

OPEN

C L O S E

O

C O EL S

P E N

PVC SLEEVE (MIN. 6" I.D.)

NOTCH PIPE TO FIT VALVE

VALVE BOX

TOP VIEW

SQUARE OR ROUND BASE

BRANCH SADDLE WITH

OUTLET

HDPE MAIN LINE

HDPE LATERAL LINE

3" MINIMUM DEPTH OF

3/4" WASHED GRAVEL

SOCKET FUSION 90° ELBOW

PE X PE BALL VALVE

PE X PE BALL VALVE

SOCKET FUSION COUPLING

(LINE SIZE PER PLAN)

HDPE MAIN LINE BELOW

SOCKET FUSION 90° ELBOW DOWN

END OF LINE

HDPE LATERAL LINE

ACME SWING JOINT

MANUFACTURED

SWING JOINT

END OF LINE

SOCKET FUSION

COUPLING

GATE VALVE W/HDPE ENDS 8" AND BELOW

HDPE MAIN LINE PIPE

FINISH GRADE

VALVE BOX

PVC SLEEVE

NOTCH PIPE TO FIT VALVE

GATE VALVE WITH BUTT FUSION STUB

ENDS

3" MINIMUM DEPTH OF

3/4" WASHED GRAVEL

FINISH GRADE

NO SCALE NO SCALE

NO SCALE

TYPICAL ROAD CROSSING - MUST BE BORED. NO OPEN CUTS ALLOWED

NO SCALE

NO SCALE

TYPICAL BRIDGE CROSSING

NO SCALE

ACME SWING JOINT

ACME SWING JOINT

ACME INLET SWING JOINT

CLEAN SOIL COMPACTED

DECODER WIRE

24"

BOTTOM OF TRENCH

MAIN LINE PIPE

POWER WIRE

6"

GRADE

REQUIRED AND MUST BE BACKFILLED

IF ROCK IS ENCOUNTERED AN

WITH CLEAN MATERIAL

ADDITIONAL 6" DEPTH IS

TYPICAL BEDDING

CRISPIN C20 AIR/VACUUM

RELEASE VALVE

2" HDPE X THREADED BRASS

TRANSITION FITTING CUT TO FIT2" SOCKET FUSION COUPLING

HDPE RISER CUT TO FIT

2" SOCKET FUSION 90°

ELBOW

3" MINIMUM DEPTH OF

3/4" WASHED GRAVEL

AIR RELIEF VALVE

2" SOCKET FUSION 90°

ELBOW

HDPE MAIN LINE

SQUARE OR ROUND BASE

BRANCH SADDLE WITH 2"

OUTLET

PVC SLEEVE

NOTCH PIPE TO FIT VALVE

JUMBO VALVE BOX

FINISH GRADE

WITH 360 POLY BALL VALVE

NO SCALE

2" 360 POLY BALL VALVE

FINISH GRADE

HDPE PIPE

HDPE SADDLE

1" ACME X 1" BRASS MALE SWING JOINT

QUICK COUPLING VALVE

QUICK COUPLING VALVE

ELECTRICAL

VALVES SURROUNDED

AND BEDDED WITH

3" MINIMUM DEPTH OF

3/4" WASHED GRAVEL

DRAIN VALVE ASSEMBLY

HDPE MAIN LINE

SQUARE OR ROUND BASE

BRANCH SADDLE WITH 2"

OUTLET

JUMBO VALVE BOX

FINISH GRADE

WITH 360 POLY BALL VALVE & ELECTRIC VALVE

NO SCALE

2" 360 POLY BALL VALVE

ELECTRIC VALVE WITH

BLACK WIRES FROM 2-WIRE PATH

RED WIRES FROM 2-WIRE PATH

2-WIRE PATH: COLOR PER SPEC.

DECODER / ICM / LSM/

214010 20M

Y09

002E86

2" TRANSITION

HDPE X STAINLESS STEEL

2" SOCKET FUSION COUPLING

2" SOCKET FUSION

COUPLING

FUSIBLE HDPE SERVICE

SADDLE

FUSIBLE HDPE SERVICE

SADDLE

FUSIBLE HDPE SERVICE

SADDLE

VALVE TO PIPE RESTRAINT

GATE VALVE - ELEVATION

(IPS)

(PJ x PJ)

VALVE TO FITTING

(IPS)

w/ PJ VALVE

GATE VALVE - PLAN

(IPS)

(PJ x PJ)

VALVE TO FITTING

(IPS)

w/ FLANGED VALVE

VALVE TO FITTING

(IPS)

w/ PJ VALVE

ANCHOR

BOLTS (TYP.)

VALVE TO FITTING

(IPS)

w/ FLANGED VALVE

FLANGED VALVE

FOR PIPE OVER 8"

VALVE TO FITTINGS W/JOINT RESTRAINTS

NO SCALE

PIPE BELL

REDUCER (IPS)

(PJ x PJ)

90° BEND (IPS)

(PJ x PJ)

TEE (IPS)

(PJ x PJ x PJ)

22.5° BEND (IPS)

(PJ x PJ)

45° BEND (IPS)

(PJ x PJ)

FLANGE ADAPTER

CONNECTION (IPS)

PJ x FLG

TEE w/ REDUCER

IN BRANCH & RUN

(IPS)

(PJ x PJ x PJ)

11.25° BEND (IPS)

(PJ x PJ)

CAP (IPS)

(PJ)

PIPE FITTINGS W/JOINT RESTRAINTS

NO SCALE

SPACED AT 12-24" APART

DateRevision/IssueNo.

Project Name and Address

SheetProject

Checked by:Drawn by:

Scale 1" = 100'-0"

Date

Member

The Irrigation Association

THIS DESIGN DRAWING IS THE PROPERTY

OF JAS IRRIGATION CONSULTING, LLC.,

DUPLICATION THEREOF IS PROHIBITED.

ANY UNAUTHORIZED USE, ALTERATION OR

IR-04

3/12/26

UNCLE REMUS GOLF COURSE

120 HAMBONE HOLLE DR

EATONTON, GA 31024

UNCLEREMUSGC2026

004331

JAS Irrigation Consulting, LLC

GROUND ROD AND GROUND PLATE FOR CONTROLLER

8'

12'

11' (MINIMUM)

CONTROLLER

ENHANCED GROUNDING DETAIL

UL LISTED 5/8" X 10' COPPER CLAD GROUND ROD

4" X 96" X .0625" GROUND PLATE

WITH CADWELD CONNECTOR

TOP VIEW

ELECTRODE SPHERE OF INFLUENCE (12" X 24')

ELECTRODE SPHERE OF INFLUENCE (10' RADIUS)

#6 AWG SOLID BARE

NOTES:

1. GROUND PLATE SHALL BE INSTALLED 30" (IN.) BELOW GRADE.

IN EARTH CONTACT MATERIAL

COPPER WIRE 2. ENCASE GROUND PLATE IN 100 LBS. OF EARTH CONTACT MATERIAL -

50 LBS. BELOW PLATE AND 50 LBS. ABOVE PLATE.

SPREAD CONTACT MATERIAL EVENLY.

3. NO OTHER WIRES OR CABLES SHALL BE INSTALLED WITHIN THE

SPHERE OF INFLUENCE.

STEP 5

STRAP TOP TO CONNECTOR

STEP 1

STEP 2

STEP 4

PUSH WIRE NUT

STEP 3

INTO CONNECTOR

TABS

PAST TABS

TWIST WIRE NUT ONTO WIRE ENDS

AND TWIST TOGETHER

STRIP WIRES 1/2" FROM ENDS

3M WIRE CONNECTION DBRY-6

NO SCALE

ADDITIONAL ELECTRICAL

GROUND ROD AND GROUND PLATE FOR GROUNDP POINTS

8'

12'

11' (MINIMUM)

ENHANCED GROUNDING DETAIL

UL LISTED 5/8" X 10' COPPER CLAD GROUND ROD

4" X 96" X .0625" GROUND PLATE

WITH CADWELD CONNECTOR

TOP VIEW

ELECTRODE SPHERE OF INFLUENCE (12" X 24')

ELECTRODE SPHERE OF INFLUENCE (10' RADIUS)

#6 AWG SOLID BARE

NOTES:

1. GROUND PLATE SHALL BE INSTALLED 30" (IN.) BELOW GRADE.

IN EARTH CONTACT MATERIAL

COPPER WIRE 2. ENCASE GROUND PLATE IN 100 LBS. OF EARTH CONTACT MATERIAL -

50 LBS. BELOW PLATE AND 50 LBS. ABOVE PLATE.

SPREAD CONTACT MATERIAL EVENLY.

3. NO OTHER WIRES OR CABLES SHALL BE INSTALLED WITHIN THE

SPHERE OF INFLUENCE.

ADDITIONAL ELECTRICAL

8'

4" X 96" X .0625" GROUND PLATE

ELECTRODE SPHERE OF INFLUENCE (12" X 24')

IN EARTH CONTACT MATERIAL

WHEN GROUNDING READINGS > 10 OHMS

12'

UL LISTED 5/8" X 10' COPPER CLAD GROUND ROD

WITH CADWELD CONNECTOR

2-WIRE SYSTEMS WITH INTEGRATED DECODER & SOLENOID

36"

Ground Plate

Valve Box

DBR/Y-6

Connectors

THE SHERE OF

INFLUENCE

Re-enterable Connector

Lightning Arrester

Decoder

Solenoid

Waterproof Connector

Integrated Device (Decoder + Solenoid)

Re-enterable Connector

Lightning Arrester

Ground Plate (4" x 36")

Powerset® Earth Contact Backfill, 50 lbs

2-Wire Decoder Cable

36" Cable Loop

Marking Tag

DECODERS PROTECTED BY EXTERNAL LIGHTNING ARRESTER:

36"

Ground Plate

Valve Box

DBR/Y-6

Connectors

THE SHERE OF

INFLUENCE

Re-enterable Connector

Lightning Arrester

Decoder To So le no id

Decoder Cable Loop - 36" from ground level to the top of the loop

Ground Plate (4" x 36") Paige 182201lC

PowerSet® Earth Contact Backfilll, 50 Lbs Paige 1820058

Marking Tag Paige 270WMT

External Arrester

Re-enterable Connector Paige 270RC4

3M DBR/Y-6

Paige 270672

2-Wire Decoder Cable

HUB

CONCRETE PAD

ROUND VALVE ECONO BOX

2" ABOVE GRADE

GRADE

6"

SLEEVE

PLATE

MATERIAL ON TOP OF

AND BELOW THE GROUND

36"

GROUND PLATE

APPROX

SECTION A

1"

1"

2"

A

SLOPE SLOPE

MATERIAL

6" DRAIN GRATE

MOISTURE TO GROUND ENHANCEMENT

NDS PLASTIC TO ALLOW

24"- 36" DEEP

W/ 25' OF #6 BARE WIRE

1 1/2 BAGS OF 50 LBS. EA.

GROUND ENHANCEMENT MIX

COPPER PLATE COVERED W/

COPPER PLATE 12X36X.06 THK

5/8" X 10' LENGTH GROUND ROD

APPROX 1" OF ENHANCEMENT

TYPICAL CONTROLLER GROUNDING

NO SCALE

1.5" GROUND CONDUIT

CONCRETE SLAB 34"L x 28"W x 6"D

1.5" AC POWER SUPPLY

FOR DECODER WIRE

3" PLASTIC SWEEP

PILOT HUB

TOP VIEW

6"

34"

6"

28"

34" 30"

6"

R

PILOT SERIES HUB

NO SCALE

MINIMUM 10'

HUNTER

PILOT-SG

TOP VIEW

2FINISH GRADE

WITH COVER

PLASTIC VALVE BOX

HUNTER GTSERIES ROTOR

WITH PILOT-100 DECODER

2 DISTANCE OF SOLID COPPER

GROUND WIRE IS AS FAR

AWAY AS WIRE SUPPLIED

(10' MINIMUM)

PILOT 2 WIRE PATH

DBRY-6 CONNECTOR

PILOT-SG "IN LINE"

SURGE ARRESTOR

10" ROUND PLASTIC

VALVE BOX

PILOT-SG

HUNTER

WIRE

CONTROL

FINISH GRADE

PILOT-SG "IN LINE" AND LINE END SURGE ARRESTOR

NO SCALE

UL LISTED 5/8" X 10' COPPER CLAD GROUND ROD

WITH CADWELD CONNECTOR

15 FOOT

5/8" X 10' GROUND ROD

NO SCALE

4" X 96" COPPER PLATE

TO 4 FEET2-1/2 FEET MINIMUM

R

1 FOOT

PILOT IRRIGATION CENTRAL

RAIN BIRD CONNECTORS

FITTING AS REQUIRED

SWING JOINT

PVC PIPE

FINISH GRADE

YELLOW SNAP RING

(DENOTES LOCATION OF ICSD)

NOT TO SCALE

AND ICSD SURGE DEVICE

RAIN BIRD VALVE IN HEAD ROTOR WITH ICM

2. AT ALL SPLICE LOCATIONS, PROVIDE SUFFICIENT SLACK TO ALLOW

THE SPLICE TO BE RAISED A MINIMUM OF 24" ABOVE GRADE FOR INSPECTION.

NOTES:

RAIN BIRD ROTOR WITH ICM

RAIN BIRD ICSD

MAXI-CABLE COLOR

PER SPECIFICATIONS

#10 AWG BARE COPPER WIRE

18" MINIMUM

UL LISTED 4" X 36" (OR EQUIVALENT)

GROUND PLATE IN 50 LB. EARTH GROUND MATERIAL

4. GROUND PLATE SHALL BE LOCATED 36" (IN.) AWAY FROM RAIN BIRD ICSD.

5. SPREAD EARTH CONTACT MATERIAL EVENLY ABOVE AND BELOW GROUND PLATE.

RAIN BIRD ICM

1. WIRE CONNECTIONS ARE AS FOLLOWS:

CONNECT BLACK WIRE(S) FROM ICM WITH BLACK WIRE FROM MAXI CABLE(S) AND ICSD

CONNECT RED WIRE(S) FROM ICM WITH RED WIRE FROM MAXI CABLE(S) AND ICSD

CONNECT GREEN WIRES FROM ICSD TO #10 BARE COPPER WIRE FROM GROUND PLATE

ALL CONNECTIONS SHALL BE MADE USING RAIN BIRD CONNECTORS.

3. THE LOCATION OF WIRE CONNECTIONS SHALL BE SNUGLY PLACED

BENEATH THE FLANGE OF THE ROTOR.

6-1 BARE COPPER

TO GROUND PLATE

AT ALL SPLICE LOCATIONS PROVIDE

SUFFICIENT SLACK TO ALLOW THE SPLICE

TO BE RAISED A MINIMUM OF 24"

ABOVE GRADE FOR INSPECTION

20'

30" (IN) MINIMUM, OR BELOW

FROSTLINE

4" DRAINAGE PIPE 18" LONG

WITH GRATE CENTERED

OVER GROUND PLATE

FILLED WITH CRUSHED STONE

4" X 96" X .0625" GROUND PLATE

SHALL BE INSTALLED A MINIMUM

OF 20' (FT) AWAY FROM STATION,

COMMUNICATION, AND POWER WIRES

100 LBS. POWERSET

EARTH CONTACT MATERIAL

(50 LBS. ABOVE PLATE,

50 LBS. BELOW PLATE)

MSP-1 SURGE ARRESTOR

MOUNTED INTO MGP-1

GROUND PLATE ASSEMBLY

GROUNDING ROD

MGP-1 GROUNDING PLATE

ASSEMBLY - CLAMPED TO

RAIN BIRD CONNECTORS

TO GROUNDING SCREWS

MSP-1 GROUND WIRES

(GREEN) - CONNECT

ON MGP-1 GROUNDING

PLATE ASSEMBLY

(COLOR PER SPEC.) SHALL HAVE

FROM CENTRAL INTERFACE

MAXI-CABLE 2-WIRE PATH

SUFFICIENT SLACK TO LIFT SPLICE

INSTALL A JUMBO VALVE BOX

ENCLOSING MGP-1, MSP-1,

GRADE FOR FUTURE ACCESS

AND GROUND ROD AT

PANDUIT CX-35 GROUND LUG

ASSEMBLY 24" ABOVE FINISH GRADE

CENTRAL EQUIPMENT

6-1 BARE COPPER FROM

COPPER CLAD GROUND ROD

TOP TO BE 6" BELOW GRADE

5/8" DIA. x 8'-0" (MIN.) UL LISTED

POLYPHASER

6-1 BARE COPPER FROM

FREEDOM SYSTEM ANTENNA

6-1 BARE COPPER FROM

MAST "U"BOLT

WEATHER STATIONS, ETC.

ADDITIONAL MGP-1/MSP-1 ASSEMBLIES

AS REQUIRED FOR ADDITIONAL WIRE PATHS,

NOTES:

1. EACH CENTRAL ASSEMBLY CAN ACCOMMODATE UP TO THREE (3)

MGP-1 GROUND PLATES FOR A TOTAL OF SIX (6) WIRE PATHS.

2. IF REQUIRED, A SECOND GROUND ASSEMBLY SHALL BE INSTALLED

WITHIN 10' (FT) OF THE FIRST ASSEMBLY TO ACCOMMODATE WIRE PATHS

7 THRU 12. RODS SHALL BE BONDED TOGETHER USING #6-1 BARE

COPPER WIRE.

3. ADDITIONAL GROUND ELECTRODES MAY BE REQUIRED IF EARTH GROUND

RESISTANCE EXCEEDS 5 OHMS.

TYPICAL GROUNDING GRID - RAIN BIRD CENTRAL EQUIPMENT & ICI+

RAIN BIRD CONNECTORS

FITTING AS REQUIRED

SWING JOINT

HDPE PIPE

BLACK WIRES FROM MAXI-CABLE

RED WIRES FROM MAXI-CABLE

FINISH GRADE

YELLOW SNAP RING

MAXI-CABLE COLOR PER SPEC.

(DENOTES LOCATION OF ICSD)

AND ICSD WITH ACCESS BOX

BLACK WIRE FROM RAIN BIRD ICSD

GREEN WIRES FROM RAIN BIRD ICSD

TOP TO BE 10" BELOW GRADE

COPPER CLAD GROUND ROD -

5/8" DIA. x 8'-0" (MIN.) UL LISTED

RAIN BIRD VALVE IN HEAD ROTOR WITH ICM

RED WIRE FROM RAIN BIRD ICSD

1. AT ALL SPLICE LOCATIONS, PROVIDE SUFFICIENT SLACK TO ALLOW

THE SPLICE TO BE RAISED A MINIMUM OF 24" ABOVE GRADE FOR INSPECTION.

NOTE:

RAIN BIRD ROTOR WITH ICM

RAIN BIRD ICSD

BURIED 4" - 6" BELOW GRADE

4" ROUND VALVE BOX (OPTIONAL)

R

LARGE TURF GEARED ROTOR TORO INF30 SERIES

FOR GOLF APPLICATIONS

NOTES:

1. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS.

2. DO NOT SCALE DRAWING.

3. CONTRACTORS NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT: www.toro.com

APPROVED BACKFILL

TM

PRESSURIZED MAIN OR LATERAL PIPE LATERAL TEE

TORO SWING JOINT

TORO INFINITY

SERIES SPRINKLER

FINISH GRADE

TO NEXT SPRINKLER

FROM SMART HUB / GATEWAY

WITH INTEGRATED LYNX SMART MODULE

LARGE TURF GEARED ROTOR TORO INF50 SERIES

FOR GOLF APPLICATIONS

NOTES:

1. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS.

2. DO NOT SCALE DRAWING.

3. CONTRACTORS NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT: www.toro.com

APPROVED BACKFILL

TM

PRESSURIZED MAIN OR LATERAL PIPE LATERAL TEE

TORO SWING JOINT

TORO INFINITY

SERIES SPRINKLER

FINISH GRADE

TO NEXT SPRINKLER

FROM SMART HUB / GATEWAY

WITH INTEGRATED LYNX SMART MODULE

FINISH GRADE

HDPE PIPE

HDPE SADDLE

1" ACME X 1" BRASS MALE SWING JOINT

QUICK COUPLING VALVE

QUICK COUPLING VALVE

These connectors were designed for installations in wet or damp locations, and are re-useable. The connector can be installed underground, in a valve box, in concrete or direct buried in earth. It can also be continually submerged in water to a maximum depth of 6 feet.

The Re-usebale connector can be used in conjunction with Decoders or Lightning Arresters or Decoder Cable Fuse Devices, or multiple wire connections.

Re-Enterable*:

Simplifies the connecting and disconnecting of ground plates and ground rods when testing earth ground resistance.

Lug:

The Lug is made from 6061-T6 aluminum alloy, providing premium electrical and mechanical performance. It can accommodate copper or aluminum wires from 14AWG to 2/0AWG.

Hex Set-Screw:

The 3/16” Hex Set-screw is radially tipped to reduce conductor strand damage when the Set-screwis tightened Rubber Covering:

The Lug is encapsulated in EPDM rubber to with-standthe rigors of the application environments.

Ribs:

The Connector main body, the Set-screw Access Plugs and the Connector Sleeves are radially ribbed to ensure a waterproof connection.

Listing:

UL Listed under UL486D for use in the USA and Canada for up to 600V.

Product Dimensions:

DIMENSIONS

Part No. No of Positions LengthWidth Height

270RC2 2 1-7/8” 2-5/8” 2-1/8”

270RC3 3 2-3/4”

270RC4 4 3-5/8”

270RC6 6 5-3/8”

270R2-IL 2 (In-Line) 5” 7/8”

SCOPE:

1.1

APPLICATION:

CONSTRUCTION:

3.1

3.2

3.3

3.4

3.5

3.6

3.7

Packaging:

Connectors are available in 3-packs. There are 30 of the 3-packs per case. The weight is 1.45 pounds per 3-pack.

Replacement Parts:

TYPICAL SPECIFICATIONS:

The Paige Electric Re-useable Connector shall be installed at all: Ground Grids, Decoder Cable Fuse Devices, Grounded Decoders, or any other grounded device. This will facilitate the testing of the earth ground resistance in decoder systems where the ground grid must be disconnected before taking its resistance reading. Paige Electric 270RCX Series. No alternates.

* The connector body and Connector Sleeve and Set-screw Access Plug must be inspected to make sure they have not been damaged before the connector is reused. All connector components and the wires must be clean before re-assembly.

1.0

2.0

3.0

3.8

3.9

Re-enterable Connectors

P7408D - Rev 5

Page 1 05/20/24

UL486D

Bonding/Shielding Wires 10 AWG Solid Bare Copper or 10 AWG Green

Wire from Ground Plate, Green/Yellow

Conductor Sleeve

Conductor Lug

Hex Set-Screw

Set-Screw Access Plug

270RCPLUG

Allen Wrench 3/16”

Ground Wire, Green.

From Decoder or Lightning Arrester

Paige No. Photo Description Packaging

270RCSLEEV Conductor Sleeve Each

270RCPLUG Set Screw Access Plug

Each

270RCGRS Silicone Lubricating Grease (8 ounces)

Each

4.0

ELECTRICAL DETAILS

DateRevision/IssueNo.

Project Name and Address

SheetProject

Checked by:Drawn by:

Scale 1" = 100'-0"

Date

Member

The Irrigation Association

THIS DESIGN DRAWING IS THE PROPERTY

OF JAS IRRIGATION CONSULTING, LLC.,

DUPLICATION THEREOF IS PROHIBITED.

ANY UNAUTHORIZED USE, ALTERATION OR

IR-05

3/12/26

UNCLE REMUS GOLF COURSE

120 HAMBONE HOLLE DR

EATONTON, GA 31024

UNCLEREMUSGC2026

004331

JAS Irrigation Consulting, LLC

WHERE WISE USE OF WATER STARTS

JAS JAS

AutoCAD SHX Text

MADE IN TAIWAN

AutoCAD SHX Text

MADE IN TAIWAN

AutoCAD SHX Text

EQUIP

AutoCAD SHX Text

FIELD

AutoCAD SHX Text

FIELD

AutoCAD SHX Text

EQUIP

AutoCAD SHX Text

MADE IN TAIWAN

AutoCAD SHX Text

MADE IN TAIWAN

AutoCAD SHX Text

EQUIP

AutoCAD SHX Text

FIELD

Putnam County BOC Page 1 of 42 Specifications

IRRIGATION PROJECT MATERIALS SPECIFICATIONS

AND DETAILS:

SOLICITATION # 26-61301-001

IRRIGATION MATERIALS FOR UNCLE REMUS GOLF COURSE

PUTNAM COUNTY, GEORGIA

Michael Benton Superintendent and Golf Course Director

Jay Swanson CID, CGIA, CLIA, CIT Irrigation Consultant JAS Irrigation Consulting Services

Putnam County BOC Page 2 of 42 Specifications

Summary Material Take Off System Performance Requirements The Uncle Remus Golf Course Representative’s Responsibility Legal Responsibilities & Public Safety Assignment Of Contract Invoicing & Timing Change Orders Document Organization Private And Public Property Ordinances, Regulations, Codes, Permits And Inspections Bidding Submittals, Include:

Quality Assurance Delivery, Storage, And Handling Sequencing And Scheduling Distributor’s Guarantee Training Of Maintenance Personnel Completion Of Project and Returns General System Components and Materials Order of Delivery and Plan Procedure ..................................................................................……. 21 Stake Out Central Control Computer Central Control System Hunter Pilot Decoder Hub Rain Bird ICI+ Unit Toro Smart Hub Sprinkler Heads Electric Valves High Density Polyethylene (HDPE) Pipe, Valves, And Fittings Combination Air/Vacuum Release Valves Valve Boxes and Lids Quick Coupling Valves Communication Wire, Grounding and Splice Installation 120 VAC Power Wiring Installation and Splicing 240 VAC Power Wiring Installation and Splicing

Putnam County BOC Page 3 of 42 Specifications

BID DETAILS

1. The undersigned Bidder offers and agrees, if this Bid is accepted, to enter into an agreement with PUTNAM COUNTY BOARD OF COMMISSIONERS dba/ UNCLE REMUS GOLF COURSE (herby referred to as UNCLE REMUS GOLF COURSE to complete all work as specified and indicated in these documents.

2. The undersigned understands and agrees that the estimated quantities for unit bid prices, if any, are to be considered as approximate only. The UNCLE REMUS GOLF COURSE does not expressly or by implication agree that the actual quantities will correspond and reserves the right to increase or decrease any quantity or to eliminate…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .