26-16_Wor982210D_schedule of prices WORKSHEET.pdf
PDF 294 KB Posted
- Attached to
- Wor982210D (East & West) 26-13 Worth
- Solicitation number
- 009-RFB-WRBWL-CY26-13
- Issued by
- Winnebago County, Iowa
About this file
This document is a Schedule of Prices worksheet for Bid No. 26-13, issued by the Iowa Department of Agriculture & Land Stewardship, Division of Soil Conservation and Water Quality, for the Wor982210D Nutrient Reduction Wetland Project located in Section 10, Township 99 North, Range 22 West, Worth County, Iowa. The project encompasses two construction sites designated as West and East, with bidders required to submit sealed bids through the Iowa Management of Procurement and Contracts System (IMPACS) by November 12, 2026 at 3:00 PM CST. A pre-bid conference is scheduled for October 27, 2026 at 10:30 AM at the USDA Service Center in Norwood. The scope of work includes site stripping and preparation, excavation and earthfill operations, installation of reinforced concrete pipe in various diameters (12" through 36"), concrete structures for intake and outlet systems, solar pump systems, tile connections, riprap placement, and seeding. The West site requires approximately 2,752 cubic yards of general excavation, 2,156 cubic yards of general dam earthfill, and installation of 279 linear feet of reinforced concrete pipe across multiple sizes, while the East site requires 845 cubic yards of general dam earthfill and 180 linear feet of 18-inch diameter reinforced concrete pipe. Construction must commence within seven days of the preconstruction meeting, with a project completion deadline of September 1, 2027, and seeding deadlines of December 15, 2027.
The estimated construction cost range is $225,000 to $325,000, with bid security required at ten percent of the bid amount and a Performance/Payment Bond equal to one hundred percent of the contract price. All bidders must be registered with the Iowa Department of Inspections, Appeals & Licensing prior to contract execution. The worksheet serves as a bidding template only, with actual bids to be submitted exclusively through the online IMPACS platform. Written technical questions regarding plans and specifications must be directed to the project engineer, Brandon Short, P.E. at Bolton & Menk (with copies to Tracy Blocker at the Division) by 3:00 PM on November 5, 2026, to be included in a final addendum. Bidders are instructed to calculate mobilization and demobilization costs as a lump sum and enter one-half of the total under each site (West and East).
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Wor982210D Nutrient Reduction Wetland Project DOCUMENT CC Bid No. 26-13 PROPOSAL AND SCHEDULE OF PRICES
CC-4
SCHEDULE OF PRICES
Wor982210D Project Contract No. 26-13 Section 10, Township 99 North, Range 22 West, Worth County, Iowa
Name of Bidder:_______________________________________________________________________________
IMPACS
No.
Eng's Item No.
Work or Material Spec No. Est Qty Unit Unit
Price Total
WEST
1.1 1 Site Stripping & Preparation IA CS-001 1.0 LS
2 Crop Damage IA CS-001 0.0
1.2 3 Structure and Channel Seeding IA CS-006 1.2 AC
4 Buffer Seeding IA CS-006 0.0
1.3 5 Mobilization and Demobilization** IA CS-008 1 LS
1.4 6 Headwall and Tile Removal IA CS-009 1 HR
1.5 7 Excavation (General) IA CS-021 2,752 CY
1.6 8 Earthfill (General) IA CS-023 165 CY
1.7 9 Earthfill (General Dam) IA CS-023 2,156 CY
1.8 10 Topsoil Placement IA CS-026 1,169 CY
11 Reinforced Concrete Pipe (RCP)
1.9 11.1 12" Dia. RCP IA CS-031 60 LF
11.2 18" Dia. RCP IA CS-031 0
1.10 11.3 24" Dia. RCP IA CS-031 38 LF
1.11 11.4 30" Dia. RCP IA CS-031 111 LF
1.12 11.5 36" Dia. RCP IA CS-031 70 LF
12 Reinforced Concrete Apron, Footing, Bar Guard
12.2 18" Dia. IA CS-031 0
1.13 13 24" Reinforced Concrete Tee IA CS-031 1 EA
14 Modified SW-401 Pump Basin IA CS-031 0
1.14 15 Modified SW-402 Pump Basin IA CS-031 1 EA
16 Solar Pump System (3 HP Turbine) IA CS-031 0
1.15 17 Solar Pump System (1.5 HP Axial) IA CS-031 2 EA
18 Concrete Structures (Inlet)
1.16 18.1 SW-512 Circular Area Intake (18") IA CS-031 2 EA
19 Concrete Structures (Outlet)
19.1 Modified SW-513 Outlet Structure (One-
Sided, 48" x 48") IA CS-031 0
1.17 19.2 Modified SW-513 Outlet Structure (Three- Sided, 48" x 48") IA CS-031 1 EA
1.18 19.3 Modified SW-513 Outlet Structure (Four- Sided, 66" x 66") IA CS-031 1 EA
1.19 20 6" Dia. PVC Pipe IA CS-045 236 LF
1.20 21 Tile Connection - 10" Dia. Or Smaller IA CS-046 2 EA
1.21 22 Tile Connection - 12" Dia. Or Larger IA CS-046 1 EA
23 CMP Tile Outlet
1.22 23.1 15" Dia. IA CS-051 1 EA
23.2 24" Dia. IA CS-051 0
1.23 23.3 36" Dia. IA CS-051 1 EA
1.24 23.4 42" Dia. IA CS-051 1 EA
1.25 24 Riprap (Class E) IA CS-061 99.0 TN
*IMPACS will not accept an amount less than 1.
** For Mobilization: Calculate your lump sum cost and put 1/2 under each site
Sub -TOTAL BASE BID……………………………………………………………………WEST…$________________
Wor982210D Nutrient Reduction Wetland Project DOCUMENT CC Bid No. 26-13 PROPOSAL AND SCHEDULE OF PRICES
CC-5
IMPACS
No.
Eng's Item No.
Work or Material Spec No. Est Qty Unit Unit
Price
EAST
2.1 1 Site Stripping & Preparation IA CS-001 1.0 LS
2 Crop Damage IA CS-001 0.0
2.2 3 Structure and Channel Seeding* IA CS-006 1.0 AC
2.3 4 Buffer Seeding* IA CS-006 1.0 AC
2.4 5 Mobilization and Demobilization** IA CS-008 1 LS
2.5 6 Headwall and Tile Removal IA CS-009 1 HR
7 Excavation (General) IA CS-021 0
2.6 8 Earthfill (General) IA CS-023 100 CY
2.7 9 Earthfill (General Dam) IA CS-023 845 CY
2.8 10 Topsoil Placement IA CS-026 327 CY
11 Reinforced Concrete Pipe (RCP)
11.1 12" Dia. RCP IA CS-031 0
2.90 11.2 18" Dia. RCP IA CS-031 180 LF
11.3 24" Dia. RCP IA CS-031 0
11.4 30" Dia. RCP IA CS-031 0
11.5 36" Dia. RCP IA CS-031 0
12 Reinforced Concrete Apron, Footing, Bar Guard
2.10 12.2 18" Dia. IA CS-031 1 EA
13 24" Reinforced Concrete Tee IA CS-031 0
2.11 14 Modified SW-401 Pump Basin IA CS-031 1 EA
15 Modified SW-402 Pump Basin IA CS-031 0
2.12 16 Solar Pump System (3 HP Turbine) IA CS-031 1 EA
17 Solar Pump System (1.5 HP Axial) IA CS-031 0 18 Concrete Strucutres (Inlet)
18.1 SW-512 Circular Area Intake (18") IA CS-031 0
19 Concrete Strucutres (Outlet)
2.13 19.1 Modified SW-513 Outlet Structure (One-Sided, 48" x 48") IA CS-031 1 EA
19.2 Modified SW-513 Outlet Structure (Three-Sided, 48" x 48") IA CS-031 0
19.3 Modified SW-513 Outlet Structure (Four-Sided, 66" x 66") IA CS-031 0
20 6" Dia. PVC Pipe IA CS-045 0
2.14 21 Tile Connection - 10" Dia. Or Smaller IA CS-046 1 EA
2.15 22 Tile Connection - 12" Dia. Or Larger IA CS-046 1 EA
* For acres, enter a unit price for 1 unit, and the bid tabulation will be adjusted based on the engineer's estimated quantity.
** For Mobilization: Calculate your lump sum cost and put 1/2 under each site
Sub -TOTAL BASE BID……………………………………………………………………EAST…$________________
Worksheet purposes only. Bids will only be accepted through the on-line Iowa Management of Procurement & Contracts System
(IMPACS).
To register and learn about IMPACS, go to:https://solutions.sciquest.com/apps/Router/SupplierLogin?CustOrg=DASIowa
END OF DOCUMENT CC
https://solutions.sciquest.com/apps/Router/SupplierLogin?CustOrg=DASIowa
File details come from the government source that posted it. Updated .