26-14_STO822305D Final Plans 2026-01-19.pdf

PDF 4 MB Posted

Attached to
26-14 Sto822305D (Story)
Solicitation number
013-RFB-3225-2027
Issued by
Taylor County, Iowa

About this file

Construction Plans for Nutrient Reduction Wetland - Story County, Iowa

This document comprises final construction plans prepared by Bolton & Menk, Inc. for the Iowa Department of Agriculture and Land Stewardship's Division of Soil Conservation and Water Quality for a solar-powered nutrient reduction wetland project (IDALS No. STO822305D) in Story County, Iowa. The project involves construction of a constructed wetland treatment system designed to reduce nutrient loading in an existing agricultural ditch system. Key project components include site preparation and stripping, excavation and grading of approximately 34,679 cubic yards, installation of 190 linear feet of 18-inch reinforced concrete pipe and 150 linear feet of 36-inch reinforced concrete pipe, placement of 1,129 linear feet of 6-inch corrugated high-density polyethylene drainage tile, construction of two solar-powered pump basins with duplex systems (3-phase, 3 HP axial pumps providing 350 GPM at 10.5 feet total dynamic head), installation of a modified SW-513 outlet structure, anti-seep collar installation, riprap placement (42.7 tons), and seeding of 11.5 acres (0.7 acres structure seeding and 10.8 acres buffer seeding). The wetland is designed with a normal water level elevation of 855.00 feet, maximum pool depth of 2.5 feet, and pool storage volume of 16.7 acre-feet at normal water level. The project includes construction access from 280th Street, with two excavation spoil piles identified on the site plan. Plans are dated January 19, 2026, and are sealed by Brandon C. Short, PE (Iowa License No. 29449, renewal date December 31, 2026).

The construction plans conform to Natural Resources Conservation Service standards, Iowa Department of Transportation specifications, and Iowa Statewide Urban Standard Specifications for Public Improvements. Detailed drawings address pipe installation methods for both reinforced concrete and corrugated polyethylene drainage tile, pump basin configuration with solar panel mounting requirements (southward orientation, two rows of seven panels spaced 20 feet apart), wetland outlet structure design with trash guards and anti-seep collars, grading and cross-sectional profiles for pool excavation and berm construction, and seeding plans for disturbed areas. All applicable federal, state, and local laws and ordinances must be observed during construction. The plans include subsurface utility information at Utility Quality Level D per CI/ASCE 38-02 standards, requiring contractors to contact Iowa One Call by phone at 811 prior to work commencement. If cultural resources are identified during construction, work must stop immediately and the local NRCS office must be notified. The document notes that there is no guarantee the wetland will fill or remain filled with water.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

210 210

5T

H A

V E

290TH ST

0T

H A

V E

T AVE

SW

RD

S

T

TH

S T

0T

H A

V E

0T

H A

V E

0T

H A

V E

0T

H A

V E

287TH ST

295TH ST

295TH ST

322ND ST

6T

H A

V E

5T

H A

V E

0T

H A

V E

0T

H A

V E

5T

H A

V E

OAK BLVD

5TH

ST

X AVE

272ND ST

250TH ST

0T

H A

V E

5T

H A

V E

5T

H A

V E

0T

H A

V E

0T

H A

V E

240TH ST

0T

H A

V E

0T

H A

V

E260TH ST

0T

H A

V E

270TH ST

305TH ST

0T

H A

V E

0T

H A

V E

290TH ST

0T

H A

V E

290TH ST

305TH ST

315TH ST

280TH ST

0T

H A

V E

320TH ST

320TH ST51

0T H

A V

E

LINCOLN HWY

TH

S T

260TH ST

270TH ST

0T

H A

V E

220TH ST

LINCOLN HWY

0T

H A

V

E LINCOLN HWY

260TH ST

260TH ST

0T

H A

V E

0T

H A

V E

5T

H A

V E

5T

H A

V E

0T

H A

V E

0T

H A

V E

280TH ST

0T

H A

V E

0T

H A

V E

0T

H A

V E

0T

H A

V E

300TH ST

315TH ST

320TH ST

0T

H A

V E

0T

H A

V E

282ND ST

280TH ST

0T H

A V

E

290TH ST

300TH ST300TH ST

310TH ST 310TH AVE

5T

H A

V E

0T

H A

V E

0T

H A

V E

C O

UN

TR

Y C

LU

B

RD

250TH ST

220TH ST

6T

H A

V E

0T

H A

V E

0T

H A

V E

0T

H A

V E

W MAPLE AVE

SA

N

D H

ILL

T

R

245TH ST

250TH ST

270TH ST

270TH ST

0T

H A

V E

265TH ST

TIM

BE

R

RD

320TH

LN

305TH

LN

4T

H A

V E

T AVE

0T

H A

V E

340TH ST340TH ST340TH ST340TH ST

ZUMWALT

STATION RD

SOUTH

S AVE

280TH

ST

0T

H A

V E

8T

H A

V E

0T

H A

V E

5T

H A

V E

303RD

ST

5T

H

A V

E

220TH ST

0T

H A

V E

306TH LN

2N

D A

V E

ONTARIO ST

2N

D A

V E

310TH ST

335TH ST

RI

V

ER

SI

D E

D R

DARTMOOR RD

C

ED

A R

LN

SO

UT

H D

A

KO

TA

A

V E

275TH

ST

3R

D A

V E

7T

H A

V E

NEVADA

KELLEY

SLATER HUXLEY

CAMBRIDGE

MAXWELL

C re ek

G ra nt

O pen

Ditch

In d ia n

W est

W alnut

S kunk

Cre ekW or le

Creek

R iver

Ea st

Ballard Creek

Coon C reek

Ru pp le

C a la m us

C reek

UNIVERSITY

SHIPLEY

IOWA

CENTER

W A S H I N G T O N

G R A N T

N E V A D A

U N I O N

P A L E S T I N E

131718

19 21 22 23

252627282930

31 32 33 34 35 36

7 8 9 11

131415161718

19 20 21 23 24

252627282930

31 32 33 34 35 36

19 20

282930

31 32

23456

7 8 9 11 12

131415161718

19 20 21 22 24

272829

32 33 34 35 36

23456

7 8 9 11 12

131415

19 20 22 23 24

252627282930

31 33 34 36

7 8

19 20

31 32

STATE

NURSERY

E57

E41

R38

R38 E63

E57

R70

R70

S14

E63

S14

R70

E63

AMES

MUNICIPAL

AIRPORT S

D A

YT

O

N A

V E

S14

I N D I A N

C R E E K

W

RD

S

T

A.01

TITLE SHEET

PROJECT DATUM: STATE PLANE

HORIZONTAL: IOWA NORTH

VERTICAL: NAVD 1988

MY LICENSE RENEWAL DATE IS

PAGES OR SHEETS COVERED BY THIS SEAL:

LICENSE NUMBER: DATE:

I OWA

LI

CE

NS

ED

PROFESS IONAL ENG

INEER

I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS

PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION

AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER

UNDER THE LAWS OF THE STATE OF IOWA.

29449

12/31/2026

ALL SHEETS

BRANDON C.

SHORT

29449

BRANDON C. SHORT, PE

STORY COUNTY, IA

CONSTRUCTION PLANS FOR

IDALS NO. STO822305D

NUTRIENT REDUCTION WETLAND

STORY COUNTY, IOWA

JANUARY 2026

THE SPECIFICATIONS AS PREPARED BY IOWA DEPARTMENT OF AGRICULTURE

AND LAND STEWARDSHIP AND BOLTON & MENK, INC. SHALL BE CONSIDERED

AS PART OF THIS DOCUMENT. NATURAL RESOURCES CONSERVATION SERVICE

CONSTRUCTION SPECIFICATIONS SHALL APPLY.

THE CURRENT EDITION OF THE "IOWA STATEWIDE URBAN STANDARD

SPECIFICATIONS FOR PUBLIC IMPROVEMENTS" SHALL GOVERN.

IOWA DEPARTMENT OF TRANSPORTATION "STANDARD SPECIFICATIONS FOR

HIGHWAY AND BRIDGE CONSTRUCTION" AND ALL CURRENT GENERAL

SUPPLEMENTAL SPECIFICATIONS AND MATERIALS INSTRUCTIONAL

MEMORANDUM SHALL GOVERN AS REFERENCED.

ALL APPLICABLE FEDERAL, STATE, AND LOCAL LAWS AND ORDINANCES WILL BE

COMPLIED WITH IN THE CONSTRUCTION OF THIS PROJECT.

GOVERNING SPECIFICATIONS

THE SUBSURFACE UTILITY INFORMATION IN THIS PLAN IS

UTILITY QUALITY LEVEL D. THIS UTILITY QUALITY LEVEL WAS

DETERMINED ACCORDING TO THE GUIDELINES OF CI/ASCE

38-02, ENTITLED "STANDARD GUIDELINES FOR THE

COLLECTION AND DEPICTION OF EXISTING SUBSURFACE

UTILITY DATA."

THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING IOWA

ONE CALL BY PHONE AT 811, OR ON THE WEB AT

HTTP://WWW.IOWAONECALL.COM/. TICKET# ___________.

TICKET NUMBER MUST BE PROVIDED TO THE NRCS PRIOR TO

COMMENCEMENT OF WORK.

NOTES

1. IF A CULTURAL RESOURCE IS IDENTIFIED DURING

CONSTRUCTION, STOP WORK IMMEDIATELY AND NOTIFY

THE LOCAL NATURAL RESOURCES CONSERVATION SERVICE

OFFICE.

2. THERE IS NO GUARANTEE THAT THE WETLAND WILL FILL OR

REMAIN FILLED WITH WATER.

R-24W

PROJECT

LOCATION

T-

N

CONSERVATION PRACTICE STANDARDS USED:

656 - CONSTRUCTED WETLAND

NRCS JOB CLASS: III

WATERSHED AREA < 300 AC

TO THE BEST OF MY PROFESSIONAL KNOWLEDGE,

JUDGEMENT, AND BELIEF, THESE PLANS MEET APPLICABLE

NRCS STANDARDS AND APPLICABLE LAWS AND

REGULATIONS.

CLIENT ACCEPTANCE

SIGNATURE DATE

R

FEETSCALE

0 1 2

T-

N

R-23W R-22W

T-

N T-

N

R-24W R-23W R-22W

SHEET INDEX

SHEET NO. SHEET TITLE

A.01 TITLE SHEET

A.02 PLAN OVERVIEW SHEET

B.01 RCP INSTALLATION DETAIL

B.02 CPDT INSTALLATION DETAIL

B.03 PUMP BASIN DETAIL

B.04 WETLAND OUTLET STRUCTURE & TRASH GUARD DETAIL

B.05 ANTI-SEEP COLLAR DETAIL

C.01 ESTIMATED QUANTITIES

D.01 GRADING OVERVIEW

D.02 INLET CHANNEL

D.03 NORTHEAST BERM & AUXILIARY SPILLWAY

D.04 SOUTH BERM

D.05 NORTH POOL CROSS SECTION (E-W)

D.06 SOUTH POOL CROSS SECTION (E-W)

D.07 POOL CROSS SECTION (N-S)

K.01 SEEDING PLAN

M.01 PUMP INLET PIPE & WETLAND OUTLET PIPE

M.02 RING TILE

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c H:

\I

DA

LS

\2

5X

0\

CA

D\

C3 D\

A0

1.

dw g 1/

/2

:1

2:

P M

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

STO822305D - BULAND WETLAND

BCS

NVD

JPR

25X.138710.000

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

AMES

© 2025 Microsoft Corporation © 2025 Maxar ©CNES (2025) Distribution Airbus DS © 2025 TomTom

BULAND, BETTY B

SMALLEY,

RAYMOND LSTORY COUNTY

STORY COUNTY

LARSON BROTHERS LLC

LARSON, SHANE

LARSON BROTHERS LLC

LARSON, SHANE

BULAND, BETTY B

BULAND, BETTY B

BULAND, BETTY B

BULAND, BETTY B GUSTAFSON,

DELWIN J & CINDY GUSTAFSON, DELWIN J & CINDY

RING TILE

6" HDPE

855 856

855854

CONSTRUCTION ACCESS

FROM 280TH ST

10 FT EMBANKMENT

TOP ELEV. 856.00

10 FT EMBANKMENT

TOP ELEV. 856.00

50 FT INLET CHANNEL

BOTTOM ELEV. 854.00

NWL = 855.00

EXCAVATE TO 854.00

PUMP INLET PIPE

18" RCP

DUPLEX SOLAR-POWERED PUMP

OUTLET STRUCTURE

MODIFIED SW-513

72" x 72"

WETLAND OUTLET PIPE

36" RCP

50 FT AUXILIARY SPILLWAY

CREST ELEV. 855.50

PROPOSED EASEMENT BOUNDARY

100-YEAR HWL = 855.95

FEMA NFHL 1% FLOOD RISK BOUNDARY

ELEV. ≈ 857

FEMA NFHL 0.2% FLOOD RISK BOUNDARY

ELEV. ≈ 858 (SITE IS WITHIN 0.2% FLOOD RISK ZONE)

PROPERTY LINES

SOLAR PANELS

EXCAVATION

SPOIL PILE

EXCAVATION

SPOIL PILE

NORMAL POOL (855.00)

100-YEAR HWL (855.95)

PROPOSED EASEMENT BOUNDARY

RIP-RAP

EXCAVATE TO 854.00

MICROTOPOGRAPHY

TREE REMOVAL

STRUCTURE SEEDING

LEGEND

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c H:

\I

DA

LS

\2

5X

0\

CA

D\

C3 D\

A0

2.

dw g 1/

/2

:1

3:

P M

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

STO822305D - BULAND WETLAND

BCS

NVD

JPR

25X.138710.000

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

A.02

PLAN OVERVIEW SHEET

R

FEETSCALE

0 100 200

HORZ.

DESIGN CRITERIA VALUE UNIT REQUIREMENT

PUMPED WATERSHED AREA 12480 ACRES

PUMP PERCENT CAPTURE 18.3%

EFFECTIVE TREATED WATERSHED 2278 ACRES

SURFACE WATERSHED AREA 174 ACRES

POOL NORMAL WATER LEVEL (NWL) ELEV 855.00 FT

DESIGNED WETLAND POOL AREA (@ NWL) 16.3 ACRES

POOL AREA TO EFFECTIVE WATERSHED AREA RATIO 0.7 % Range 0.5% to 2% of watershed area

MAXIMUM POOL DEPTH 2.5 FT

AVERAGE POOL DEPTH 1.0 FT

DEEP WATER AREA (DEPTH > 3 FT) 0.0 ACRES

PERCENT DEEP WATER TO POOL AREA 0.0 % Less than 25%

POOL STORAGE VOLUME AT NWL 16.7 ACRE-FT

OVERFLOW ELEVATION 855.50 FT

POOL STORAGE VOLUME AT OVERFLOW 25.0 ACRE-FT

PRIMARY WEIR ELEVATION 855.00 FT

PRIMARY WEIR WIDTH 22 FT Four 5.5-foot openings

TOTAL EASEMENT AREA 41.6 ACRES

AREA OF BUFFER 25.3 ACRES

RATIO BUFFER AREA TO NWL POOL AREA 1.6 Less than 4

AVERAGE CAPTURE FLOW 0.5 CFS

25-YEAR STORM HWL IN POOL 855.8 FT

25-YEAR PEAK INFLOW 85 CFS

25-YEAR PEAK OUTFLOW 73 CFS

100-YEAR STORM HWL IN POOL 855.95 FT

100-YEAR PEAK INFLOW 119 CFS

100-YEAR PEAK OUTFLOW 105 CFS

WETLAND ELEV INCREMENTAL CUMULATIVE CUMULATIVE

POOL DEPTH AREA VOLUME VOLUME

(FT) (FT) (FT2

) (FT3

) (AC-FT)

0.0 852.5 10,000

0.5 853.0 26,700 9,175 0.21

1.0 853.5 32,000 23,850 0.55

1.5 854.0 37,700 41,275 0.95

1.5 854.0 664,500 41,275 0.95

2.0 854.5 681,100 377,675 8.67

2.5 855.0 710,200 725,500 16.66

3.0 855.5 746,400 1,089,650 25.01

3.5 856.0 1,122,900 1,556,975 35.74

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c H:

\I

DA

LS

\2

5X

0\

CA

D\

C3 D\

B0

1.

dw g 1/

/2

:1

3:

P M

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

STO822305D - BULAND WETLAND

BCS

NVD

JPR

25X.138710.000

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

B.01

RCP INSTALLATION DETAIL

TRENCH INSTALLATION TYPE 3

COMPLETELY FILL

HAUNCH AREA WITH

GRAVELLY SAND

COMPACT TO 85%

STANDARD PROCTOR

DENSITY.

Do

LOOSELY PLACED UNCOMPACTED

GRAVELLY SAND BEDDING

Do/3

3" MIN.

PIPE SPRINGLINE

GRAVELLY SAND BEDDING SHALL BE CONSISTENT WITH THE GRADATION AND

OTHER CHARACTERISTICS OF STANDARD AASHTO A1 OR A3 SOIL. A

REPRESENTATIVE SAMPLE OF THE MATERIAL AND A GRADATION REPORT OR

SUPPLIER'S CERTIFICATION OF COMPLIANCE SHALL BE SUBMITTED TO THE

ENGINEER FOR APPROVAL PRIOR TO DELIVERY TO SITE. SEE SOIL DATA IN

APPENDIX OF SPECIFICATIONS BOOKLET.

6" TYP

0" MIN MEASURE POINT FOR

MAXIMUM TRENCH WIDTH

TOP OF

PIPE

CRUSHED ROCK MEETING THE GRADATION OF SUDAS CLASS I BEDDING

MATERAL, SPECIFICATION SECTION 3010.2.02.A, MAY BE SUBSTITUTED FOR

THE SAND OR CLAY HAUNCH BACKFILL MATERIAL. NO COMPACTION WILL BE

REQUIRED FOR THE CRUSHED ROCK BEDDING AND BACKFILL. MATERIAL

COSTS SHALL BE INCIDENTAL TO PIPE INSTALLATION.

MODIFIED TRENCH INSTALLATION TYPE 4

COMPLETELY FILL HAUNCH

AREA WITH NON-SATURATED

SILTY CLAY OR CLAY SOIL.

COMPACT TO 85% STANDARD

PROCTOR DENSITY. THERE

ARE NO SPECIFIED MOISTURE

LIMITS.

Do

WHERE TRENCH BOTTOM IN FIRM UNDISTURBED SOIL,

SHAPE TRENCH BASE GROOVE TO MATCH MINIMUM

1/6 OF THE OUTER CIRCUMFERENCE OF THE PIPE.

WHERE THE SHAPED GROOVE CANNOT BE

CONSTRUCTED INTO UNDISTURBED GROUND OR

WHERE EXCESS CUT OCCURS OVER EXCAVATE AND

PLACE MINIMUM 3-INCH THICK COMPACTED GRAVELLY

SAND BEDDING TO RESTORE GRADE SUCH THAT 1/6 OR

MORE OF THE OUTER CIRCUMFERENCE OF THE PIPE IS

BEDDED. THIS MATERIAL AND WORK IS SUBSIDIARY TO

THE INSTALLATION OF THE PIPE. CONTRACTOR MAY

SUBSTITUTE PIPE BEDDING ROCK AS THE BEDDING

MATERIAL. IT ALSO IS SUBSIDIARY.

PIPE SPRINGLINE

6" TYP

0" MIN MEASURE POINT FOR

MAXIMUM TRENCH WIDTH

TOP OF

PIPE

MINIMUM TRENCH WIDTH SHALL BE OUTSIDE DIAMETER OF PIPE PLUS 12" OR

THAT WIDTH WHICH IS REQUIRED FOR COMPACTION, WHICHEVER IS GREATER

WHERE FIRM BASE IS NOT

ENCOUNTERED. OVER

EXCAVATE AS DIRECTED BY

ENGINEER. PLACE CRADLING

ROCK AND BED PIPE IN IT

SUCH THAT 1/6 OR MORE OF

THE OUTER CIRCUMFERENCE

OF THE PIPE IS SUPPORTED.

THIS ROCK IS PAID FOR UNDER

A SEPARATE BID ITEM.

THE CONTRACTOR IS SOLEY RESPONSIBLE FOR THE INSTALLATION OF ALL PIPE ACCORDING TO PLAN REQUIREMENTS.

THE CONTRACTOR'S PARTICIPATION IN AND COMPLIANCE WITH THE FOLLOWING PROCEDURE IS REQUIRED AND WILL

ALLOW FOR FEWER SOIL DENSITY TESTS TO ENSURE PROPER PIPE INSTALLATION.

STEP 1

BEFORE COMMENCING PIPE INSTALLATION, STANDARD SOIL PROCTOR DENSITY TEST RESULTS OF REPRESENTATIVE SAMPLE(S) OF PIPE HAUNCH FILL SHALL BE PROVIDED BY AN INDEPENDENT QUALIFIED SOILS TESTING LAB. THE SELECTION OF THE SAMPLE(S) WILL BE MADE BY THE ENGINEER AND CONTRACTOR (WHEN SPECIFIED).

STEP 2

CONTRACTOR MAY BEGIN EXCAVATING THE MODIFIED TYPE 4 TRENCH

WITH THE REQUIRED SHAPED BOTTOM GROOVE AND PLACE SEVERAL PIPE SECTIONS ONLY WHEN BOTH ENGINEER AND

TESTING LAB TECHNICIAN ARE PRESENT

CONTRACTOR SHALL DEMONSTRATE THE INTENDED METHODS FOR COMPACTING THE FILL FOR THE PIPE HAUNCH AREAS. SOIL DENSITY TESTS SHALL BE TAKEN AT LOCATIONS DESIGNATED BY THE ENGINEER TO CONFIRM THAT THE INTEDNED METHODS FOR FILL AND COMPACTION OF THE PIPE HAUNCH AREAS SATIFIES THE PLAN REQUIREMENTS.

CONTRACTOR SHALL MODIFIY THE INSTALLATION METHODS AND REPEAT STEP 2 UNTIL ACCEPTABLE TESTS RESULTS ARE

ACHIEVED.

STEP 3

CONTRACTOR MAY INSTALL THE NEXT SEVERAL HUNDRED FEET OF PIPE. ENGINEER SHALL DESIGNATE SEVERAL LOCATIONS (APPROXIMATELY 10% OF THE INSTALLED LENGTH) WHERE CONTRACTOR SHALL LEAVE THE PIPE UNBLINDED FOR FURTHER DENSITY TESTS OF THE HAUNCH FILL AREA. ALL DENSITY TESTS MUST MEET PLAN REQUIREMENTS BEFORE

WORK MAY PROCEED FURTHER.

IF DENSITY TESTING DATA CONFIRMS TO THE SATISFACTION OF THE ENGINEER THAT THE CONTRACTOR'S INSTALLATION METHOD WILL PRODUCE CONSISTENT COMPLIANCE WITH PLAN REQUIREMENTS, CONTRACTOR MAY CONTINUE INSTALLATION OF THE PIPE WITH NO ADDITIONAL TESTING REQUIRED. IF NOT, STEPS 2 AND 3 SHALL BE REPEATED UNTIL A RELIABLE, SUCCESSFUL METHOD OF PIPE INSTALLATION THAT PRODUCES SATISFACTORY RESULTS IS ESTABLISHED.

TRENCH WALLS

PLUG DOWNSTREAM

TILE WITH PLASTIC END

PLUG, CONCRETE, OR

AS OTHERWISE

ALLOWED.FLOW FLOW

CUT AND SHAPE END OF P.E.

TILE TO FIT FLUSH WITH INSIDE

OF CONCRETE TILE. GROUT

CONNECTION

FILL TRENCH TO P.E. SPRINGLINE WITH COMPACTED CRUSHED

STONE. WHERE COVER EXCEEDS 8 FEET, COVER CONNECTION

AND EXPOSED P.E. WITH 12 INCHES OF CRUSHED STONE

BEDDING COMPLYING WITH SUDAS SPECIFICATION SECTION

3010.301. BUCKET PRESS & COMPACT EARTH FILL UNIFORMLY

ON BOTH SIDES OF STONE TO RESIST LATERAL MOVEMENT OF

THE STONE.

CONCRETE COLLAR EXCEPTION

CONNECTIONS TO THE PIPE AT BOTH ENDS MAY BE MADE

WITH A MANUFACTURED POLYETHYLENE INTERNAL SNAP

COUPLER INSERTED FULLY INTO THE PIPE. CONCRETE COLLARS

NOT REQUIRED WITH POSITIVE LOCKED CONNECTION OR

WHERE COMPACTED CRUSHED ROCK FULLY SURROUNDS THE

CONNECTION. GAPS AT THE CONNECTIONS SHALL BE COVERED

WITH ENGINEERING FABRIC WRAPPED AROUND THE JOINT.

INSERTA TEE WILL BE CONSIDERED AS ALTERNATE

CONNECTION AT NEW MAIN WITH ENGINEERS PRIOR

APPROVAL AND INSTALLATION PER MANUFACTURERS

RECOMMENDATION.

TYPICAL FIELD TILE CONNECTION

FOR FIELD TILE UP TO 10" DIAMETER

CO

VE

R

USE NON-PERFORATED

CORRUGATED P.E. DRAIN TILE

UNDISTURBED

SOIL

SLIDE CORRUGATED P.E. TILE A

MINIMUM OF 6" OVER END OF

EXISTING TILE. ENCASE JOINT (IF

NOT TIGHT FITTING) IN P.C.

CONCRETE COLLAR, AS SHOWN.

FIELD TILE

A

A

PIPE HAUNCH FILL AND COMPACTION METHOD

PLAN REQUIREMENTS COMPLIANCE VERIFICATION

12"

6"

HAND SHAPE TRENCH FOR P.E.

TILE TO INSURE UNDISTURBED

SOIL SUPPORT LOWER 1/2 OF

TILE PERIMETER OR BED ON

CRUSHED STONE FILL AND

THOROUGHLY TAMP SOIL

ENVELOPE

SECTION A-A

TOP OF SOIL

ENVELOPE

UNDISTURBED

SOIL

CONTRACTOR IS REQUIRED TO PROPERLY AND ADEQUATELY INSTRUCT SUBCONTRACTORS AND/OR SUBSEQUENT PIPE

INSTALLATION WORKERS ON THE PROPER INSTALLATION METHOD.

STEP 4A

SOIL OR TRENCH CONDITION CHANGES

TO VERIFY CONTRACTOR'S COMPLIANCE WITH PLAN REQUIREMENTS UNDER THE CHANGED CONDITIONS, ENGINEER MAY STOP WORK AND REQUIRE ADDITIONAL SOIL PROCTOR TESTS AND/OR SOIL DENSITY TESTS SIMILAR TO STEPS 1 THROUGH

3. THE WORK AND COSTS OF THE FIRST TWO REVERIFICATIONS IS SUBSIDIARY TO THE PIPE INSTALLATION. SUBSEQUENT

VERIFICATIONS WILL BE CONSIDERED EXTRA WORK.

STEP 4B

CONTRACTOR FAILS TO CONSISTENTLY PERFORM INSTALLATION METHOD OR INSTRUCT OTHER INSTALLERS

IF CONTRACTOR FAILS TO CONSISTENTLY PERFORM OR ADEQUATELY INSTRUCT SUBCONTRACTORS AND/OR SUBSEQUENT PIPE INSTALLATION WORKERS ON THE APPROVED INSTALLATION METHOD, ENGINEER MAY STOP WORK AND REQUIRE ADDITIONAL SOIL PROCTOR TESTS AND/OR SOIL DENSITY TESTS SIMILAR TO STEPS 1 THROUGH 3 TO VERIFY CONTRACTOR'S COMPLIANCE WITH PLAN REQUIREMENTS. THE WORK AND COSTS OF ALL VERIFICATIONS UNDER SUCH

CONDITIONS IS SUBSIDIARY TO THE PIPE INSTALLATION.

EXCEPTION

IF CONTRACTOR ELECTS TO SHAPE THE TRENCH BOTTOM SUCH THAT A MINIMUM OF 45% OF THE OUTER CIRCUMFERENCE OF THE PIPE IS FIRMLY BEDDED IN AND CONSISTENTLY SUPPORTED BY UNDISTURBED SOIL, PIPE HAUNCH FILL COMPACTION TESTING WILL NOT BE REQUIRED. THE CONTRACTOR IS REQUIRED TO COMPLY WITH A PROPER INSTALLATION METHOD AND TO FULLY COMPLY WITH THE REQUIREMENTS OF THE VERIFICATION OUTLINED

ABOVE FOR ALL SITUATIONS WHERE THIS EXCEPTION IS NOT MET.

NOT TO SCALE

SOURCE: AMERICAN CONCRETE PIPE ASSOCIATION

CONCRETE PIPE DESIGN MANUAL

NOT TO SCALE

SOURCE: AMERICAN CONCRETE PIPE ASSOCIATION

CONCRETE PIPE DESIGN MANUAL

ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c H:

\I

DA

LS

\2

5X

0\

CA

D\

C3 D\

B0

1.

dw g 1/

/2

:1

3:

P M

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

STO822305D - BULAND WETLAND

BCS

NVD

JPR

25X.138710.000

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

B.02

CPDT INSTALLATION DETAIL

FLAT BOTTOM TRENCH INSTALLATION

FILL TRENCH TO 6" ABOVE TOP OF PIPE WITH CRUSHED STONE OR GRAVEL

MEETING THE REQUIREMENTS IN TABLE 2. BEDDING MATERIAL SHALL BE

INCIDENTAL TO THE PIPE INSTALLATION.

PREFFERED TRENCH INSTALLATION BOTTOM

CORRUGATED POLYETHYLENE DRAINAGE TUBING

MATERIAL & INSTALLATION NOTES

NOT TO SCALE

SOURCE: ASTM F449

TRAPEZOIDAL GROOVE, "V" GROOVE, & CIRCULAR GROOVE

NOT TO SCALE

SOURCE: ASTM F449

6" MIN FOR

OPEN TRENCH

INSTALLATION

R

6" M

IN

A B G

0.

5R

0.

R

TRENCH WIDTH MEASURED

AT TOP OF PIPE

90° "V" GROOVE

90°

THE CIRCULAR GROOVE SHALL BE A

MINIMUM 0.35R DEEP AND SHALL

MATCH THE OUTSIDE CURVE

SHAPE OF THE DEFLECTED CPDT.

THE TRAPEZOIDAL GROOVE SHALL

BE SHAPED AND ADJUSTED SUCH

THAT POINTS A, B, & C WILL TOUCH

THE UNDEFLECTED CPDT FOR EACH

SIZE INSTALLED.

TRAPEZOIDAL GROOVE

CIRCULAR GROOVE

UNDISTURBED SOIL

UNDISTURBED SOIL

TRENCH WIDTH MEASURED

AT TOP OF PIPE

4" M

IN

SEE TABLE 2 FOR

BEDDING MATERIAL

NOTE: THIS IS AN ALLOWED ALTERNATIVE INSTALLATION FOR CPDT

1. ALL CPDT AND CONNECTORS FURNISHED SHALL BE IN COMPLIANCE WITH MATERIAL STANDARDS ASTM F405 AND F667, AS

APPLICABLE, AND SHALL BE CLASSIFIED AS HEAVY-DUTY UNDER THOSE STANDARDS.

2. EXCEPT MODIFIED HEREIN OR OTHERWISE APPROVED BY ENGINEER, ALL CPDT SHALL BE INSTALLED IN COMPLIANCE WITH THE

ASTM 449 STANDARD PRACTICE.

3. FOR PIPES 6” DIAMETER AND SMALLER A 90° V GROOVE BOTTOM MAY BE USED, FOR ALL LARGER PIPE A TRAPEZOIDAL BOTTOM OR A CIRCULAR BOTTOM CONFORMING TO THE OUTSIDE DIAMETER OF THE PIPE SHALL BE USED. PRIOR TO THE INSTALLATION OF CPDT, CONTRACTOR MUST PROVE TO ENGINEER THAT THE INSTALLATION REQUIREMENTS, INCLUDING THE

SHAPE OF THE TRENCH BOTTOM, WILL BE ACCOMPLISHED.

4. WHERE TRENCH BOTTOM IS IN FIRM UNDISTURBED SOIL, SHAPE TRENCH BASE GROOVE. WHERE EXCESS CUT OCCURS, OVEREXCAVATE AND PLACE MINIMUM THREE (3) INCH THICK, GRAVELLY SAND BEDDING TO RESTORE GRADE. THIS BEDDING SHALL MEET THAT REQUIRED FOR TRENCH INSTALLATION TYPE 3 ON PLAN SHEET B.02. THIS MATERIAL AND WORK SHALL BE INCIDENTAL TO THE INSTALLATION OF THE PIPE. CONTRACTOR MAY SUBSTITUTE PIPE BEDDING ROCK AS THE BEDDING

MATERIAL.

5. NATIVE SOILS MAY BE USED AS BACKFILL MATERIAL UNLESS UNSTABLE TRENCH CONDITIONS PREVENT THE TRENCH BOTTOM HOLDING THE SHAPED GROOVE. IF TRENCH BOTTOM WILL NOT HOLD GROOVE SHAPE CONTRACTOR SHALL NOTIFY ENGINEER IMMEDIATELY. A FLAT BOTTOM TRENCH INSTALLATION WILL THEN BE ASSUMED. THE REQUIRED BEDDING MATERIAL SHALL BE

INCIDENTAL TO THE INSTALLATION OF THE PIPE.

6. MINIMUM TRENCH WIDTH IS PIPE OUTSIDE DIAMETER PLUS FOUR (4) INCHES FOR PLOWED INSTALLATION AND PIPE OUTSIDE

DIAMETER PLUS TWELVE (12) INCHES FOR OPEN TRENCH INSTALLATION.

7. ALL LATERAL CONNECTIONS, ELBOWS, TEES, ALIGNMENT CURVES, START HOLES AND ALL PORTIONS OF THE TRENCH NOT MEETING THE GROOVED TRENCH INSTALLATION REQUIREMENTS SHALL BE FILLED TO A MINIMUM OF SIX (6) INCH COVER OVER THE PIPE WITH GRADED CRUSHED STONE OR GRAVEL AS SHOWN ON TABLE 2 OF THIS SHEET. BEDDING MATERIAL SHALL BE

INCIDENTAL TO THE INSTALLATION OF THE PIPE.

8. MANUFACTURER'S ENDCAPS SHALL BE INSTALLED AT THE TERMINATION OF EACH LINE UNLESS A CONNECTION TO AN EXISTING

DRAIN IS MADE.

9. WITH THE INSTALLATION OF THE FIRST REACH OF CPDT ON THE PROJECT, CONTRACTOR IS REQUIRED TO WORK WITH THE

ENGINEER TO CHECK AND CONFIRM THAT THE PIPE STRETCH, IF ANY, DOES NOT EXCEED 5%.

10. ALIGNMENT TURNS MAYBE MADE USING EITHER A MANUFACTURED FITTING OR CURVING THE LINE WITH A 25' MINIMUM

RADIUS.

R25'

PI

X °

PT

PT

Table 1 Maximum Allowable Buried Depth to Flowline of CPDT

Nominal Pipe Diameter (IN)

Pipe Quality

(ASTM)

Trench Width at Top of the Pipe (FT)

12" 18" 24" 30" or Greater

Standard 13 7 5.5 5

Heavy-duty Any 10 7 6

Standard 10 7 5.5 5

Heavy-duty Any 9.5 6.5 6

Standard 10 7 5.5 5

Heavy-duty Any 10 7 6

10 Heavy-duty ... 9 7 6 12 Heavy-duty ... 9 7 6 15 Heavy-duty ... ... 7 6

Table 2 Acceptable Bedding Material and Compaction Requirements

Description Percentage Passing Sieve Sizes Minimum

Standard Density (%)

Maximum Compaction Layer Height

(IN.)1" 3/4" No. 4

Crushed Stone Crushed Gravel* 100% > 95% < 5% Dumped 18

* Class 1 Bedding Material Per SUDAS 3010.202A is an Allowable Substitute

DEGREES Δ DELTA

20° 4.41 30° 6.7 45° 10.36 60° 14.43 70° 17.51 80° 20.98 90° 25 ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c H:

\I

DA

LS

\2

5X

0\

CA

D\

C3 D\

B0

1.

dw g 1/

/2

:1

3:

P M

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

STO822305D - BULAND WETLAND

BCS

NVD

JPR

25X.138710.000

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

B.03

PUMP BASIN DETAIL

SOLAR

NOTE: SOLAR PANELS SHALL BE INSTALLED IN THE LOCATION SHOWN ON

A.02 AND M.01 WITH A SOUTHWARD ORIENTATION.

SOLAR POWERED PUMP SYSTEM (BID ITEM 16) SHALL INCLUDE THE FOLLOWING:

· SOLAR PANELS

· SOLAR DRIVE

· 3-PHASE, 3 HP AXIAL PUMP (CARRY CP-04 WITH 17° IMPELLER OR

APPROVED EQUAL, PROVIDING 350 GPM AT 10.5 FT TDH)

· FLOAT SWITCH

· MOUNTING CLAMPS FOR CONTROLLER

· SOLAR PANEL MOUNTING KIT

· STEEL PIPE EXTENDERS

· WIRED GENERATOR PLUG

· LIGHTNING & SURGE PROTECTOR

· WIRING FOR PANELS, PUMP, AND CONTROLLER

CONTRACTOR SHALL PROVIDE THE FOLLOWING, SUBSIDIARY TO BID ITEM XX:

· STEEL PIPE FOR MOUNTING

· CONCRETE AND ROCK BEDDING FOR MOUNTING POLES

· PVC DISCHARGE PIPE

· CHECK VALVE

PUMP BASIN (BID ITEM XX) SHALL INCLUDE THE FOLLOWING:

· PUMP BASIN (MODIFIED SW-401, SEE DETAILS)

· STEEL LID WITH STAND

MOUNT PUMP CONTROLLER TO

SOLAR POSTS

INSTALL SOLAR DRIVES NEXT TO PUMPS

ON POSTS ABOVE ELEV. 862.00

FILL HOLE WITH CONCRETE

MIN. 12" DIAMETER

FLOW

EXTERIOR MASTIC &

FABRIC WRAP

ALL JOINTS - 9" WIDE

4'

14'

MIN. 12"

18" RCP

FL EL = 847.10

PAINTED STEEL LID WITH ACCESS HATCH

TOP EL = 860.00

8" PVC PUMP OUTLET

EL = 857.00

EXISTING GROUND

APPROX. EL = 857.00

NORMAL POOL = 855.00

EXCAVATED POOL

8" MIN. CLASS I BEDDING MATERIAL

SUMP = 840.00

SUDAS SW-402 STRUCTURE

2 FT

PLACE RIP RAP

SEE M.01

INSTALL PUMP CONTROL PANELS

ADJACENT TO PUMP BASIN OR ON

EMBANKMENT. MOUNT ON

POSTS ABOVE ELEVATION 862.00.

INSTALL CHECK VALVE

FLEXIBLE WATERTIGHT SEALS

4'

17'

18" RCP

FL EL = 847.10

PAINTED STEEL LID WITH ACCESS HATCH

TOP EL = 860.00

8" PVC PUMP OUTLET

EL = 857.00

8" MIN. CLASS I BEDDING MATERIAL

SUMP = 840.00

SUDAS SW-402 STRUCTURE

FLEXIBLE WATERTIGHT SEALS

FLOAT ELEVATIONS

PUMP 1 PUMP 2

ON 846.60 847.10

OFF 842.50 843.00

NORTH

20 FT

4" SCHEDULE 40 STEEL PIPE REQUIRED: 4 x 21' *CUT TWO IN HALF TO MAKE 4 x 10.5' IN GROUND POST

PUMP CONTROLLER AND SOLAR PANELS SHALL BE

ENTIRELY ABOVE THE ELEVATION 862.00.

PIPE INCLUDED IN KIT

GROUND SURFACE

20 FT

4.5 TO 5 FT

3 TO 3.5 FT

3.5 FT 21 FT

INSTALL SOLAR ARRAYS IN TWO ROWS

OF 7 PANELS. ARRAYS SHALL HAVE A

SOUTHWARD ORIENTATION AND BE

SPACED 20 FT APART.

DPC2500

SOLAR DRIVE

SOLAR

DISCONNECT

PUMP WIRING DIAGRAM

NOT TO SCALE

SW-402 WEIR & PUMP BASIN ELEVATION

NOT TO SCALE

XXX FT

SW-402 WEIR & PUMP BASIN ELEVATION

NOT TO SCALE

ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c H:

\I

DA

LS

\2

5X

0\

CA

D\

C3 D\

B0

1.

dw g 1/

/2

:1

3:

P M

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

STO822305D - BULAND WETLAND

BCS

NVD

JPR

25X.138710.000

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

B.04

WETLAND OUTLET STRUCTURE DETAIL

TOP OF STRUCTURE ELEVATION (SEE PROFILE)

A B.01

A

6" SUMP

FL ELEV (SEE PROFILE)

PRECAST OPENING ELEVATION

PROVIDE FLEXIBLE, WATERTIGHT GASKET FOR PIPE OPENINGS

SEE SUDAS FOR SW-513 DETAILS

PRECAST STRUCTURE SHALL BE ONE SECTION OR

PROVIDE WATERTIGHT SEAL BETWEEN SECTIONS.

72" WALL

WIDTH

72" WALL WIDTH

1.25'

SEE SUDAS FOR SW-513 DETAILS

OUTLET PIPE

BEDDING PER SUDAS72" WALL WIDTH

2 LF 12" DUAL-WALL HDPE

12" HICKENBOTTOM INTAKE

OR APPROVED EQUAL

2 LF 12" DUAL-WALL HDPE

12" HICKENBOTTOM INTAKE OR APPROVED EQUAL

12" 90° ELBOW

EXCAVATED WETLAND POOL

EXCAVATE 1 FT ADDITIONAL AROUND INTAKE

PLACE RIP RAP IN 3-FT DIA. CIRCLE AROUND INTAKE

UNDERLAY WITH GEOTEXTILE (1.5 TN)

PLACE RIP RAP IN 6-FT DIA. CIRCLE AROUND INTAKE

UNDERLAY WITH GEOTEXTILE (1.5 TN)

AGRI DRAIN IN-LINE

WATER LEVEL CONTROL

STRUCTURE OR

APPROVED EQUAL

ATTACH TO CONCRETE

STRUCTURE

AGRI DRAIN IN-LINE WATER LEVEL CONTROL

STRUCTURE OR APPROVED EQUAL

STUB IN 12" PIPE

BACKFILL MIN. 1 FT AROUND

WCS WITH 1" CLEAN ROCK

NORMAL WATER LEVEL

9" INLET OPENING

ON ALL SIDES

6" x 6" CENTER

PIER ON ALL

SIDES

STRUCTURE LID PER SUDAS

FIT WITH SW-604 TYPE 5 CASTING

3 FT

SECTION

MODIFIED SW-513

OUTLET STRUCTURE

PLAN

MODIFIED SW-513

OUTLET STRUCTURE

NOT TO SCALE

NOT TO SCALE

NOTES:

1. ALL FASTENERS SHALL BE GALVANIZED OR STAINLESS STEEL.

2. HICKENBOTTOM INTAKE, WATER LEVEL CONTROL

STRUCTURE, DUAL-WALL HDPE, ELBOW, TRASH GUARD,

CASTING, AND ALL HARDWARE AND APPURTENANCES

SHOWN ON THIS PAGE OR REQUIRED FOR INSTALLATION

ARE SUBSIDIARY TO THE OUTLET STRUCTURE.

36" RCP OUTLET PIPE

OPENINGS FOUR

SIDES WITH

CENTER PIERS

ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c H:

\I

DA

LS

\2

5X

0\

CA

D\

C3 D\

B0

1.

dw g 1/

/2

:1

3:

P M

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

STO822305D - BULAND WETLAND

BCS

NVD

JPR

25X.138710.000

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

B.05

TRASH GUARD & ANTI-SEEP COLLAR DETAIL

1/2" X 2" SLOTTED HOLES

FOR 3/8" DIA. BOLTS

CONTINUOUS WELD

BETWEEN BAND

AND COLLAR.

3.75'

3.75'

12'

SLOTTED HOLES

@ 8" O.C.

CONTINUOUS WELD

BETWEEN BAND

AND COLLAR.

BAND

BOTTOM OF BAND

2" 2"

BAND

A

A

12"TOP OF BAND

BOTTOM OF COLLAR

CORRUGATED METAL SHEET WELDED

TO CENTER OF SMOOTH METAL

BAND WITH MASTIC APPLIED FOR

SEALANT AROUND THE PIPE.

OPTIONAL SUBSTITUTE -

CAST-IN-PLACE CONCRETE BAND.

CORRUGATED METAL SHEET

GALVANIZED STEEL

PREFABRICATED HPDE ANTI-SEEP

COLLARS ARE AN ALLOWED ALTERNATIVE.

BAND

12" ID

RCP

TRENCH WIDTH (SEE PLANS)

5 FT MIN. COLLAR WIDTH

FT

C O

LL

AR

TH

IC

KN

ES

S

NOTES:

1. COMPOSITE BENTONITE AGGREGATE

(CBA) SHALL BE AQUABLOK OR

APPROVED EQUAL.

2. COLLAR SHALL EXTEND 1.75 FT BELOW

BOTTOM OF PIPE AND 1.75 FT ABOVE

TOP OF PIPE

3. COLLAR SHALL BE A MINIMUM OF 5 FT

WIDE AND EXTEND A MINIMUM OF 6"

BEYOND EDGE OF TRENCH

4. NO COMPACTION OF CBA IS

REQUIRED.

5. EXCAVATE AND BACKFILL THE

REMAINDER OF THE TRENCH AS

NOTED IN THE PLANS.

ANTI-SEEP COLLAR DETAILS

ALTERNATIVE 2: COMPOSITE BENTONITE AGGREGATE

COLLAR

NOT TO SCALE

ALTERNATIVE 1: RCP ANTI-SEEP COLLAR

NOT TO SCALE

48"

SHEET STEEL

SHEET STEEL

90"

GROUND CONTACT

TREATED POST

4"x4"

MODIFIED SW-513

OUTLET STRUCTURE

12" MIN. SPACE

BELOW GUARD

24"

CONCRETE FOOTINGS

MIN 12" DIAMETER

4 FT MIN.

EMBEDMENT

STRUCTURE

OPENING

BOLT SHEET STEEL TO

ANGLE IRON ANCHORED

ONTO STRUCTURE

GRADE BELOW TRASH

GUARD TO PROVIDE 12"

MINIMUM SPACE

BETWEEN BOTTOM OF

STEEL AND TOP OF RIP RAP

(TYP. ALL SIDES)

SHEET STEEL

TRASH GUARD FOR WETLAND OUTLET STRUCTURE

NOT TO SCALE

NOTE: TRASH GUARD AND APPURTENANCES ARE TYPICAL FOR ALL SIDES OF OUTLET STRUCTURE. QUANTITIES

AND DIMENSIONS FOR STEEL SHEETS PER SIDE OF STRUCTURE ARE AS FOLLOWS:

1 - STEEL SHEET - 90" x 24" x 3/8" 2 - STEEL SHEETS - 48" x 24" x 3/8"

ANGLE IRON--EITHER WELDED OR BOLTED--ON TOP AND BOTTOM OF EACH SHEET AS BRACE.

BOLT TRASH GUARD ONTO ANGLE IRON ANCHORED TO OUTLET STRUCTURE.

PROVIDE THREE POSTS WITH CONCRETE FOOTINGS ON EACH SIDE

GRADE AS NECESSARY TO ALLOW FLOW OF WATER UNDER TRASH GUARD WITH 12" MINIMUM CLEARANCE.

ALL FASTENERS SHALL BE GALVANIZED OR STAINLESS STEEL

ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c H:

\I

DA

LS

\2

5X

0\

CA

D\

C3 D\

C0

1.

dw g 1/

/2

:1

3:

P M

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

STO822305D - BULAND WETLAND

BCS

NVD

JPR

25X.138710.000

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

C.01

ESTIMATED QUANTITIES

Bid Item Description Specifications

Plan No.

Estimated Quantities

No. Page Quantity Unit

1 Site Stripping & Preparation IA CS-001 3 A.02 1 LS

2 Crop Damage IA CS-001 3 0 AC

3 Structure and Channel Seeding IA CS-006 7 K.01 0.7 AC

4 Buffer Seeding IA CS-006 7 K.01 10.8 AC

5 Mobilization and Demobilization IA CS-008 11 1 LS

6 Excavation (General) IA CS-021 16 D.01 34,679 CY

7 Earthfill (General) IA CS-023 19 D.01 64 CY

8 Earthfill (General Dam) IA CS-023 19 D.01, D.03-D.04 317 CY

9 Earthfill (Dam Core) IA CS-023 19 D.04 1,110 CY

10 Topsoil Strip, Salvage, and Respread IA CS-026 23 D.01 8,593 CY

11 18" Dia. Reinforced Concrete Pipe IA CS-031 25 B.01, M.01 190 LF

12 36" Dia. Reinforced Concrete Pipe IA CS-031 25 B.01, M.01 150 LF

13 18" Dia. Concrete Apron, Footing, Bar Guard IA CS-031 25 M.01 1 EA

14 36" Dia. Concrete Apron, Footing, Bar Guard IA CS-031 25 M.01 1 EA

15 SW-402 Pump Basin IA CS-031 25 B.03, M.01 1 EA

16 Solar Pump System IA CS-031 25 B.03, M.01 2 EA

17 72" x 72" Modified SW-513 Outlet Structure IA CS-031 25 B.04, M.01 1 EA

18 6" Dia. Corrugated HDPE Pipe (Single-Wall; Perforated) IA CS-046 33 B.02, M.02 1,044 LF

19 6" Dia. Corrugated HDPE Pipe (Single-Wall; Non-Perforated) IA CS-046 33 B.02, M.02 85 LF

20 Anti-Seep Collars IA CS-051 37 B.05, M.01 3 EA

21 8" Dia. CMP Tile Outlet (20 LF Each) IA CS-051 37 M.02 1 EA

22 Rip Rap (Class E) IA CS-061 41 M.01 42.7 TN

BULAND, BETTY B

SMALLEY,

RAYMOND L

STORY COUNTY

STORY COUNTY

LARSON BROTHERS LLC

LARSON, SHANE

LARSON BROTHERS LLC

LARSON, SHANE

BULAND, BETTY BBULAND, BETTY B

BULAND, BETTY B

BULAND, BETTY B GUSTAFSON,

DELWIN J & CINDY GUSTAFSON, DELWIN J & CINDY

10 FT EMBANKMENT

TOP ELEV. 856.00

50 FT INLET CHANNEL

ELEV. 854.00

10:1 SIDES

NWL = 855.00

EXCAVATE POOL TO 854.00

GRADE OUT AT 10:1

EXCAVATE TO 854.00

50 FT AUXILIARY SPILLWAY

CREST ELEV. 855.50

3:1 SIDES

PROPERTY LINES

EXCAVATE CHANNEL TO 854.00

GRADE OUT AT 10:1

EXCAVATE TO 853.00

440'x17' 4:1 SIDES85

855 856

855854

EXCAVATE TO 852.50

50'x50' 4:1 SIDES

EXCAVATE TO 853.00

440'x17' 4:1 SIDES

EXCAVATE TO 852.50

50'x50' 4:1 SIDES

EXCAVATE TO 852.50

50'x50' 4:1 SIDES

EXCAVATE TO 852.50

50'x50' 4:1 SIDES

SPOIL PILE

SPOIL PILE

10 FT COVER BERM

SEE M.01

4:1 SIDES

10 FT EMBANKMENT

TOP ELEV. 856.00

4:1 SIDES

NORMAL POOL (855.00)

100-YEAR HWL (855.95)

PROPOSED EASEMENT BOUNDARY

RIP-RAP

EXCAVATE TO 854.00

MICROTOPOGRAPHY

TREE REMOVAL

MINIMUM 6" TOPSOIL LAYER

STRUCTURE SEEDING

LEGEND

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c H:

\I

DA

LS

\2

5X

0\

CA

D\

C3 D\

D0

1.

dw g 1/

/2

:1

4:

P M

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

STO822305D - BULAND WETLAND

BCS

NVD

JPR

25X.138710.000

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

D.01

GRADING OVERVIEW

R

FEETSCALE

0 100 200

HORZ.

0+50 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00 12+50

9.

6.

6.

6.

6.

6.

6.

6.

6.

6.

6.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

4.

4.

4.

4.

4.

4.

4.

4.

4.

4.

3.

3.

3.

3.

3.

3.

3.

3.

3.

3.

VPI: 2+15.24

EL: 856.94

VPI: 2+27.00

EL: 854.00

VP

I:

+1

7.

EL

: 8

.9

9EXISTING GROUND SURFACE NWL = 855.00

END INLET CHANNEL

BEGIN POOL

INLET CHANNEL

EXCAVATE TO 854.00

50 FT INLET CHANNEL

EXCAVATE TO 854.00

0+00

1+00

2+00

3+00

4+00

5+00

6+00

7+00

8+00

9+00

10+00 11+00

12+00

12+50

BP

: 0

+0 0.

PC

: 1

0+

.4

PT: 11+23.74

EP: 12+50.00

858 857

855 854

PUMP INLET PIPE

SEE M.01

EXCAVATION SPOIL PILE

EXCAVATION SPOIL PILE

NORMAL POOL (855.00)

100-YEAR HWL (855.95)

PROPOSED EASEMENT BOUNDARY

RIP-RAP

EXCAVATE TO 854.00

MICROTOPOGRAPHY

TREE REMOVAL

STRUCTURE SEEDING

LEGEND

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c H:

\I

DA

LS

\2

5X

0\

CA

D\

C3 D\

D0

2.

dw g 1/

/2

:1

4:

P M

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

STO822305D - BULAND WETLAND

BCS

NVD

JPR

25X.138710.000

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

R

FEETSCALE

0 40 80

HORZ.

FEETSCALE

0 5 10

VERT. D.02

INLET CHANNEL

INLET CHANNEL

3:1 SIDES

INLET CHANNEL TYPICAL SECTION

EXISTING GROUND

50 FT BOTTOM

-1+00 0+00 1+00 2+00 3+00 4+00

5.

6.

5.

5.

5.

6.

6.

6.

6.

6.

0.00%VP

I:

0+

.0

EL

: 8

.0

VP

I:

2+

.3

EL

: 8

.0

010 FT EMBANKMENT

TOP ELEV. 856.00

EXISTING GROUND SURFACE

0+00 1+00 2+00 3+00

BP

: 0

+0 0.

EP

: 3

+0 0.

+0

855854

-1+00 0+00 1+00 2+00 3+00 4+00

5.

5.

5.

6.

6.

4.

5.

5.

4.

0.00% -0.75%

VP

I:

0+

.3

EL

: 8

.5

VP

I:

1+

.0

EL

: 8

.5

VP

I:

2+

.1

EL

: 8

.5

EXISTING GROUND SURFACE 50 FT AUXILIARY SPILLWAY

CREST ELEV. 855.50

0+00

1+00

2+00

3+00

BP: 0+00.00

PC: 1+50.00

PT

: 2

+0 4.9

EP

: 3

+0 0.0

WETLAND OUTLET PIPE

SEE M.01

NORMAL POOL (855.00)

100-YEAR HWL (855.95)

PROPOSED EASEMENT BOUNDARY

RIP-RAP

EXCAVATE TO 854.00

MICROTOPOGRAPHY

TREE REMOVAL

STRUCTURE SEEDING

LEGEND

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c H:

\I

DA

LS

\2

5X

0\

CA

D\

C3 D\

D0

2.

dw g 1/

/2

:1

4:

P M

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

STO822305D - BULAND WETLAND

BCS

NVD

JPR

25X.138710.000

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

R

FEETSCALE

0 40 80

HORZ.

FEETSCALE

0 5 10

VERT. D.03

NORTHEAST BERM & AUXILIARY SPILLWAY

R

NORTHEAST BERM TYPICAL SECTION

EXISTING GROUND

10 FT TOP

4:1

4:1

AUXILIARY SPILLWAY TYPICAL SECTION

EXISTING GROUNDTOP OF

EMBANKMENT

50 FT BOTTOM

3:1 3:1

NORTHEAST BERM AUXILIARY SPILLWAY

-1+25 -1+00 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 10+75

6.

6.

6.

5.

5.

5.

5.

5.

5.

5.

5.

4.

4.

4.

4.

5.

5.

4.

5.

6.

6.

6.

6.

6.

6.

6.

6.

6.

6.

6.

6.

6.

6.

6.

6.

6.

0.00%VP

I:

1+

.7

EL

: 8

.0

VP

I:

9+

.7

EL

: 8

.0

010 FT EMBANKMENT

TOP ELEV. 856.00

EXISTING GROUND SURFACE

NWL = 855.00

BOTTOM OF CORE TRENCH

5 FT BELOW EXISTING

GROUND SURFACE

TOP OF CORE TRENCH AT NWL

ELEV. 855.00

0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 9+50

BP

: 0 +0

0.

EP

: 9

+5 0.

855856 856855

85586

WETLAND OUTLET PIPE

SEE M.01

EXCAVATION SPOIL PILE

NORMAL POOL (855.00)

100-YEAR HWL (855.95)

PROPOSED EASEMENT BOUNDARY

RIP-RAP

EXCAVATE TO 854.00

MICROTOPOGRAPHY

TREE REMOVAL

STRUCTURE SEEDING

LEGEND

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c H:

\I

DA

LS

\2

5X

0\

CA

D\

C3 D\

D0

2.

dw g 1/

/2

:1

4:

P M

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

STO822305D - BULAND WETLAND

BCS

NVD

JPR

25X.138710.000

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

R

FEETSCALE

0 40 80

HORZ.

FEETSCALE

0 5 10

VERT. D.04

SOUTH BERM

SOUTH BERM

SOUTH BERM TYPICAL SECTION

EXISTING GROUNDEXCAVATED

POOL

4:14:1

10 FT TOP

0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00

5.

6.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

6.

6.

9.

8.

7.

7.

3.

3.

4.

3.

2.

2.

2.

2.

2.

2.

2.

2.

2.

3.

NWL = 855.00

EXCAVATION SPOIL PILE

WETLAND DEEP CHANNEL

BOTTOM ELEV. 853.00

EXCAVATED WETLAND POOL

BOTTOM ELEV. 854.00

EXISTING GROUND SURFACE

EXISTING GROUND SURFACE

NWL = 855.00

50 FT INLET CHANNEL

BOTTOM ELEV. 854.00

0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00

BP

: 0

+0 0.

EP

: 1

2+

.0

EXCAVATION SPOIL PILE

EXCAVATION SPOIL PILE

NORMAL POOL (855.00)

100-YEAR HWL (855.95)

PROPOSED EASEMENT BOUNDARY

RIP-RAP

EXCAVATE TO 854.00

MICROTOPOGRAPHY

TREE REMOVAL

STRUCTURE SEEDING

LEGEND

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c H:

\I

DA

LS

\2

5X

0\

CA

D\

C3 D\

D0

2.

dw g 1/

/2

:1

4:

P M

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

STO822305D - BULAND WETLAND

BCS

NVD

JPR

25X.138710.000

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

R

FEETSCALE

0 40 80

HORZ.

FEETSCALE

0 5 10

VERT. D.05

NORTH POOL CROSS SECTION (E-W)

NORTH POOL CROSS SECTION (E-W)

0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00

6.

6.

6.

6.

6.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

6.

6.

9.

8.

8.

4.

5.

6.

7.

8.

9.

5.

3.

3.

2.

2.

2.

2.

2.

2.

2.

2.

2.

3.

NWL = 855.00

EXCAVATION SPOIL PILE

WETLAND DEEP CHANNEL

BOTTOM ELEV. 853.00

EXCAVATED WETLAND POOL

BOTTOM ELEV. 854.00

EXISTING GROUND SURFACE

EXISTING GROUND SURFACE

50 FT INLET CHANNEL

BOTTOM ELEV. 854.00

EXCAVATION SPOIL PILE

0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00

BP

: 0

+0 0.

EP

: 1

2+

.0

EXCAVATION SPOIL PILE

EXCAVATION SPOIL PILE

NORMAL POOL (855.00)

100-YEAR HWL (855.95)

PROPOSED EASEMENT BOUNDARY

RIP-RAP

EXCAVATE TO 854.00

MICROTOPOGRAPHY

TREE REMOVAL

STRUCTURE SEEDING

LEGEND

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c H:

\I

DA

LS

\2

5X

0\

CA

D\

C3 D\

D0

2.

dw g 1/

/2

:1

4:

P M

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

STO822305D - BULAND WETLAND

BCS

NVD

JPR

25X.138710.000

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

R

FEETSCALE

0 40 80

HORZ.

FEETSCALE

0 5 10

VERT. D.06

SOUTH POOL CROSS SECTION (E-W)

SOUTH POOL CROSS SECTION (E-W)

0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00

6.

6.

6.

6.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

5.

1.

1.

1.

1.

1.

9.

7.

5.

3.

3.

3.

3.

3.

3.

3.

3.

3.

3.

3.

3.

5.

NWL = 855.00

EXCAVATION SPOIL PILE

WETLAND DEEP CHANNEL

BOTTOM ELEV. 853.00

EXCAVATED WETLAND POOL

BOTTOM ELEV. 854.00

EXISTING GROUND SURFACE

EXISTING GROUND SURFACE

0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00

BP

: 0

+0 0.

EP

: 1

2+

.0

856857858

856857

855 854

EXCAVATION SPOIL PILE

NORMAL POOL (855.00)

100-YEAR HWL (855.95)

PROPOSED EASEMENT BOUNDARY

RIP-RAP

EXCAVATE TO 854.00

MICROTOPOGRAPHY

TREE REMOVAL

STRUCTURE SEEDING

LEGEND

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c H:

\I

DA

LS

\2

5X

0\

CA

D\

C3 D\

D0

2.

dw g 1/

/2

:1

4:

P M

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

STO822305D - BULAND WETLAND

BCS

NVD

JPR

25X.138710.000

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

R

FEETSCALE

0 40 80

HORZ.

FEETSCALE

0 5 10

VERT. D.07

POOL CROSS SECTION (N-S)

POOL CROSS SECTION (N-S)

SEED EXCAVATION SPOIL PILE EXTENTS

BUFFER SEEDING

SEED EXCAVATION SPOIL PILE EXTENTS

BUFFER SEEDING

SEED DISTURBED AREAS TO 1 FT

BELOW NORMAL POOL

BUFFER SEEDING

SEED DISTURBED AREAS TO 1 FT

BELOW NORMAL POOL

BUFFER SEEDING

SEED NORTHEAST BERM

STRUCTURE SEEDING

SEED SOUTH BERM

STRUCTURE SEEDING

SEED AUXILIARY SPILLWAY

AND SURROUNDING AREA

STRUCTURE SEEDING

SEED OUTLET PIPE COVER BERM

STRUCTURE SEEDING

DO NOT SEED POOL

SEEDING AREAS

BUFFER SEEDING 10.8 AC

STRUCTURE SEEDING 0.7 AC

7 85

856856

NORMAL POOL (855.00)

100-YEAR HWL (855.95)

PROPOSED EASEMENT BOUNDARY

RIP-RAP

EXCAVATE TO 854.00

MICROTOPOGRAPHY

TREE REMOVAL

STRUCTURE SEEDING

LEGEND

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c H:

\I

DA

LS

\2

5X

0\

CA

D\

C3 D\

K0

1.

dw g 1/

/2

:1

4:

P M

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

STO822305D - BULAND WETLAND

BCS

NVD

JPR

25X.138710.000

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

K.01

SEEDING PLAN

R

FEETSCALE

0 100 200

HORZ.

-0+50 0+00 1+00 2+00 3+00

7.

9.

9.

7.

6.

6.

6.

6.

6.

7.

6.

7.

9.

9.

7.

6.

6.

6.

6.

6.

6.

6.

-1.00%

VPI: 0+30.00

EL: 849.00

VPI: 2+20.00

EL: 847.10

190' - 18" RCP @ 1.00%

190 LF - 18" RCP

@ 1.00% 2030

PU

M

P

BA

SI

N

(S

TA

+2

0) M

O

DI

FI

ED

S W

-4

SE

E

B.

TO

P

0.

FL

IN

.1

(1

8" S

ST

A

0+

" C

O N

CR

ET

E

AP

RO

N

FO

O

TI

N G, B

AR

G U

AR

D

FL

O

U T

9.

(1 8"

N

EXCAVATED WETLAND POOL

EXISTING GROUND SURFACE

NWL = 855.00

0+00 1+00 2+00 2+50

BP

: 0

+0 0.

EP

: 2

+5 0.

EXCAVATION

SPOIL PILE

EXCAVATION

SPOIL PILE

50-FT WIDTH TREE

REMOVAL OVER PIPE

RIP RAP

6 FT x 27 FT

12.8 TONS

RIP RAP

10 FT x 12 FT

9.5 TONS

STA 0+30

18" CONCRETE APRON,

FOOTING, BAR GUARD

FL OUT = 849.00 (18" N)

PUMP BASIN (STA 2+20)

MODIFIED SW-402

SEE B.03

TOP = 860.00

FL IN = 847.10 (18" S)

INSTALL SOLAR PANELS ON

POSTS ABOVE ELEV. 865.00

-0+75 0+00 1+00 2+00 2+75

4.

4.

4.

5.

4.

3.

7.

6.

8.

7.

4.

4.

4.

5.

4.

3.

7.

6.

8.

6.

-0.67%

.00

% -0.65%

150' - 36" RCP @ 0.67%

150 LF - 36" RCP

@ 0.67% 9545

O U

TL

ET

S

TR

U

CT

U

RE

(S

TA

+4

5) M

O

DI

FI

ED

S W

-5

"x

SE

E

B.

TO

P

6.

O

PE

N

IN

G

5.

FL

O U

T

0.

(3

6" S

ST

A

1+

" C

O N

CR

ET

E

AP

RO

N

FO

O

TI

N G, B

AR

G U

AR

D

FL

IN

.0

(3

6" N

VPI: 0+45.00

EL: 850.00 VPI: 1+95.00

EL: 849.00

COVER BERM

3 FT COVER REQUIRED

EXCAVATED WETLAND POOL

NWL = 855.00

EXISTING GROUND SURFACE

10 FT EMBANKMENT

SEE D.04

ANTI-SEEP COLLARS

SEE B.05

0+00 1+00 2+00 2+25

BP

: 0

+0 0.

EP

: 2

+2 5.

RIP RAP

12 FT x 20 FT

18.9 TONS

50-FT WIDTH TREE

REMOVAL OVER PIPE

RIP RAP

SEE B.04

1.5 TONS

OUTLET STRUCTURE (STA 0+45)

MODIFIED SW-513

72"x72"

SEE B.04

TOP = 856.25

OPENING = 855.00

FL OUT = 850.00 (36" S)

STA 1+95

36" CONCRETE APRON,

FOOTING, BAR GUARD

FL IN = 849.00 (36" N)

10 FT COVER BERM

NORMAL POOL (855.00)

100-YEAR HWL (855.95)

PROPOSED EASEMENT BOUNDARY

RIP-RAP

EXCAVATE TO 854.00

MICROTOPOGRAPHY

TREE REMOVAL

STRUCTURE SEEDING

LEGEND

R

FEETSCALE

0 25 50

HORZ.

FEETSCALE

0 5 10

VERT. M.01

PUMP INLET PIPE & WETLAND OUTLET PIPE

R

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c H:

\I

DA

LS

\2

5X

0\

CA

D\

C3 D\

M

.d w g

1/

/2

:1 4:

P

M

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

STO822305D - BULAND WETLAND

BCS

NVD

JPR

25X.138710.000

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

PUMP INLET PIPE WETLAND OUTLET PIPE

10 FT TOP

4:1 SIDES

COVER BERM TYPICAL SECTION

EXISTING GROUND

0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00

6.

6.

6.

6.

6.

6.

6.

6.

5.

5.

5.

5.

6.

6.

5.

6.

6.

0.

2.

2.

2.

2.

1.

1.

1.

1.

1.

1.

1.

1.

1.

1.

1.

1.

1.

1.

1.

1.

1.

1.

1.

-0.10%

VP

I:

0+

.0

EL

: 8

.2

VP

I:

+5

4.

EL

: 8

.0

1044' - 6" HDPE @ 0.10%

1044 LF - 6" PERFORATED HDPE

@ 0.10% 4905

85' - 6" HDPE @ 0.10%

85 LF - 6" NON-PERFORATED HDPE

@ 0.10% 34

EXISTING GROUND SURFACE

NON-PERFORATED PIPE OUTSIDE OF CROP LAND

20 LF 8" CMP TILE OUTLET

EXISTING GROUND SURFACE

0+00 1+00

2+00 3+00

4+00 5+00

6+00 7+00

8+00 9+00

10+00

11+00

12+00

BP

: 0

+0 0.

PI

: 1

0+

.7

EP: 12+00.00

20 LF 8" CMP TILE OUTLET

50-FT WIDTH TREE

REMOVAL OVER TILE

855854

NORMAL POOL (855.00)

100-YEAR HWL (855.95)

PROPOSED EASEMENT BOUNDARY

RIP-RAP

EXCAVATE TO 854.00

MICROTOPOGRAPHY

TREE REMOVAL

STRUCTURE SEEDING

LEGEND

R

FEETSCALE

0 40 80

HORZ.

FEETSCALE

0 5 10

VERT. M.02

RING TILE

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c H:

\I

DA

LS

\2

5X

0\

CA

D\

C3 D\

M

.d w g

1/

/2

:1 4:

P

M

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

STO822305D - BULAND WETLAND

BCS

NVD

JPR

25X.138710.000

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

RING TILE

Sheets and Views
A.01 TITLE SHEET
A.02 PLAN OVERVIEW SHEET
B.01 RCP INSTALLATION DETAIL
B.02 CPDT INSTALLATION DETAIL
B.03 PUMP BASIN DETAIL
B.04 WETLAND OUTLET STRUCTURE DETAIL
B.05 TRASH GUARD & ANTI-SEEP COLLAR DETAIL
C.01 ESTIMATED QUANTITIES
D.01 GRADING OVERVIEW
D.02 INLET CHANNEL
D.03 NORTHEAST BERM & AUXILIARY SPILLWAY
D.04 SOUTH BERM
D.05 NORTH POOL CROSS SECTION (E-W)
D.06 SOUTH POOL CROSS SECTION (E-W)
D.07 POOL CROSS SECTION (N-S)
K.01 SEEDING PLAN
M.01 PUMP INLET PIPE & WETLAND OUTLET PIPE
M.02 RING TILE

File details come from the government source that posted it. Updated .