This document is an Addendum #1 for the KC Brookside Flooring Replacement Project issued by Kueny Architects for the County of Kenosha Purchasing Division. The project involves a flooring replacement in the lower level kitchen and dishwashing areas, with bids due by 1:00 PM on August 27, 2025. The addendum clarifies that two existing steamers will be removed by the General Contractor but not replaced, and will be replaced by the owner under a separate contract. The project includes demolition of existing sheet vinyl flooring, removal and relocation of various kitchen equipment, and installation of new flooring with options for polished concrete or tile finishes.
The addendum introduces a new specification for stainless steel wall base (Polished Flooring Option) with specific details including the basis of design by JTC Metals, a 4 Brushed Finish with kick, 20ga thickness, and 6" height. Revisions are noted for the A201 and A202 floor plan drawings, with owner-replaced equipment added to the plans and the stainless steel wall base incorporated into the proposed design. The project includes alternate options for flooring finishes and wall treatments, with specific instructions for painting existing surfaces and preparing the area for new installations.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Vendor Responsibility Form Construction.pdf | ||
| 2518 Drawings.pdf | ||
| 2518 Bid Documents.pdf | ||
| 2518 Specifications.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
KC Brookside – Flooring Replacement Project
ADDENDUM #1
August 13, 2025
BIDS DUE: Bids must be submitted No later than 1:00 PM August 27, 2025 to: County of Kenosha Purchasing Division 1010 56th Street, Second Floor Kenosha, WI 53140
LATE BIDS WILL BE REJECTED
There will be a public opening for this Bid conducted at 1010 56th Street, Second Floor Kenosha, WI 53140.
This Addendum is issued to modify, explain or correct the original Drawings and Specifications as noted below, and is hereby made a part of the Contract documents.
Please attach this Addendum to the Specifications in your possession. Acknowledge receipt of this Addendum in the space provided on the Bid Form. Failure to do so may subject Bidder to disqualification.
This Addendum consists of (1) written page, (2) attachments, and (1) sign in sheet
QUESTIONS AND ANSWERS
1. At the walk-through meeting, it was stated there are two pieces of owner equipment that will be removed by the General Contractor but not replaced.
Please clarify the equipment and locations.
a. See the attached drawing sheet with noted equipment to be replaced by the owner under a separate contract. They are the (2) steamers shown in the photos below.
REVISED / ADDED SPECIFICATION
1. 10 80 00 MISCELLANEOUS SPECIALITES
a. Stainless steel wall base (Polished Flooring Option)
-2-
i. Basis of Design: JTC Metals, Stainless steel wall base
1. Architects approved equal.
ii. Finish: 4 Brushed Finish, with Kick
iii. Thickness: 20ga
iv. Height: 6”
REVISIONS TO THE DRAWINGS
1. A201 – Floor Plan – Lower Level – Existing and Demo
a. Owner replaced equipment added to the plans.
2. A202 – Floor Plan – Lower Level – Proposed
a. Stainless Steel wall base added to the project.
8"
13'�6"
5" 6'�4"
12'�0"
5" 4'�6"
5" 7'�7"
�1
FREE�ER T� RE�AI�
EXISTI�G
C���ER T� RE�AI�
EXISTI�G
C���ER T� RE�AI�
EXISTI�G
�FFICE T� RE�AI�
EXISTI�G
ST�RAGE T� RE�AI�
EXISTI�G
1. DEMOLITION NOTES AND PLANS ARE PROVIDED AS A
REFERENCE. CONTRACTOR TO VERIFY EXISTING
CONDITIONS AND EXAMINE DRAWINGS AND DETAILS TO
DETERMINE EXTENT AND LIMITS OF DEMOLITION REQUIRED
TO ACCOMMODATE NEW CONSTRUCTION.
2. REFER TO CONSULTANT DRAWINGS FOR ADDITIONAL
DEMOLITION OF OTHER DISCIPLINES.
3. PROVIDE AND COORDINATE ALL DEMOLITION AND NEW
CONSTRUCTION WITH PROPOSED PLAN DIMENSIONS AND
INSTALLATION OF NEW MATERIALS AND FINISHES.
DEMOLITION TO BE IN ACCORDANCE WITH NEW FINAL
PRODUCT.
4. PROVIDE SMOOTH AND CLEAN SURFACE TO ALL AREAS
RECEIVING NEW FINISHES. COORDINATE WORK WITH PLANS
AND THE ROOM FINISH SCHEDULE TO COMPLY WITH NEW
PROPOSED MATERIAL.
5. ALL RELATED WOOD BLOCKING, HARDWARE CONNECTION
DEVICES, ADHESIVES, AND/OR MASTIC SHALL BE REMOVED
FROM SURFACES AT ITEMS NOTED FOR DEMO. PROVIDE
SURFACES ACCEPTABLE FOR PATCHING AND/OR NEW
CONSTRUCTION.
6. IDENTIFICATION AND/OR ABATEMENT OF HAZARDOUS
MATERIALS IS NOT PART OF THIS SCOPE OF WORK. IF
ASBESTOS OR OTHER HAZARDOUS MATERIALS ARE
ENCOUNTERED, THE CONTRACTOR SHALL NOTIFY THE
OWNER IMMEDIATELY.
7. REMOVE LOOSE PAINT AND MISCELLANEOUS HANGING
OBJECTS FROM WALLS AND CEILINGS AT ALL AREAS TO
RECEIVE NEW FINISHES.
8. OPENING IN THE EXISTING STRUCTURE SMALLER THAN 12"
IN ANY DIRECTION ARE NOT IDENTIFIED ON THESE
DRAWINGS. SUB-CONTRACTORS SHALL BE RESPONSIBLE
FOR PROVIDING OPENINGS SMALLER THAN 12" AS
REQUIRED FOR INSTALLATION OF THEIR WORK.
9. OPENINGS IN THE EXISTING STRUCTURE SHALL NOT BE MADE
WITHOUT PRIOR APPROVAL OF THE STRUCTURAL ENGINEER.
10. PATCH AND REPAIR ALL EXISTING FLOOR SLABS AND WALL
SURFACES DAMAGED FROM DEMOLITION OR PRIOR USE.
11. PATCH ALL AREAS OF ELECTRICAL AND MECHANICAL
DEMOLITION THAT WILL NOT BE REUSED.
12. DO NOT REMOVE ANY ITEMS WHICH JEOPARDIZE THE
STRUCTURAL INTEGRITY OF THE BUILDING. IF HIDDEN
ELEMENTS OR DETERIORATED ELEMENTS ARE
ENCOUNTERED, NOTIFY THE ARCHITECT IMMEDIATELY.
13. PROTECT ALL ADJACENT AREAS AND ITEMS "TO REMAIN"
DURING DEMOLITION/CONSTRUCTION. REPAIR/REPLACE ALL
ITEMS DAMAGED DURING CONSTRUCTION.
14. EXISTING BUILDING CONDITIONS SHOWN ON THESE
DRAWINGS ARE DERIVED FROM DRAWINGS OF THE ORIGINAL
BUILDING AND FROM LIMITED FIELD OBSERVATION.
15. INDICATED EXISTING BUILDING CONDITIONS ARE ASSUMED TO
BE REPRESENTATIVE OF THE ACTUAL CONSTRUCTION OF
THE BUILDING.
FIELD CONDITIONS MAY VARY.
16. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN
ADDITIONAL MEANS OF EGRESS AS NEEDED AS A RESULT OF
CONSTRUCTION SEQUENCING AND/OR REGULATORY
REQUIREMENTS
17. G.C. IS RESPONSIBLE FOR ALL DEMO WORK REQUIRED FOR
THE COMPLETION OF THE PROPOSED SCOPE OF WORK;
REFER TO ALL BASE BID AND ALTERNATE PLANS. ALL
CUTTING AND PARCHING REQUIRED IS THE RESPONSIBILITY
OF THE G.C.
"A�� AREAS SH�W� AS DIAG��A� HATCH T� RE�AI�
EXISTI�G U"�"�"
I�DICATED GE�ERA� (BUT ��T �I�ITED T�) AREA OF
WORK
1 DEMO EXISTING SHEET VINYL FLOORING; PREP SUB FLOOR FOR NEW
FLOORING INSTALL
2 EXISTING DISHWASHING SINK; G.C. TO RELOCATE FOR STORAGE AND
RE-INSTALL; PROVIDE ALL REQUIRED PLUMBING DISCONNECT AND
SHUTOFF
3 EXISTING DISHWASHING SINK AND PREP COUNTER; G.C. TO
RELOCATE FOR STORAGE AND RE-INSTALL
4 EXISTING STORAGE RACKING; G.C. TO RELOCATE FOR STORAGE AND
RE-INSTALL
5 EXISTING MOBILE STORAGE UNITS; G.C. TO RELOCATE FOR STORAGE
AND RE-INSTALL
6 EXISTING FOOD WARMING UNIT; G.C. TO RELOCATE FOR STORAGE
AND RE-INSTALL
7 DEMO EXISTING COVE BASE AND TRIM; COMPLETE SYSTEM FOR NEW
FLOORING SYSTEM
8 RELOCATE EXISTING ICE MAKER FOR STORAGE AND RE-INSTALL
9 DEMO EXISTNG EYE WASH STATION; REPLACE WITH NEW UNIT
10 DEMO ALL DOOR TRANSITIONS; TYPICAL ALL IN REPLACEMENT AREA -
G.C. TO FIELD VERIFY AND REPLACE ALL
11 REMOVE EXISTING COOKING EQUIPMENT; G.C. TO PROVIDE ALL
DISCONNECTS AND REMOVAL FOR STORAGE; G.C. TO RE-INSTALL
AFTER FLOORING REPLACEMENT
12 CLEAN ALL EXISTING TILE AND STAINLESS STEEL; COMPLETE ROOM
EQUIPMENT STORAGE
BUILDING LOCATION
PROJECT AREA
H
OWNER:
PROJECT:
PROJECT
PROJECT ISSUE DATE:
©2025 Kueny Architects L.L.C. - All Rights Reserved
10505 Corporate Drive, Pleasant Prairie, WI 53158 phone: 262.857.8101 web: www.kuenyarch.com
A
1 2 3 4
1 2 3 4
X
B
C
D
X X
X
A
B
C
D
CONSULTANTS
REV # DESCRIPTION DATE
REVISIONS
KEY PLAN
PLAN NORTH
SHEET
SHEET TITLE:
ARCHITECT
Kueny Architects Phone: 262.857.8101 Address: 10505 Corporate Drive, Suite 100 Pleasant Prairie, Wisconsin 53158
Architect of Record - Jon P. Wallenkamp P:414.690.3197
Project Manager - Lee Anderson P:262.945.7709
KEYNOTE LEGEND
/1
/2
:4
:1
A
M
SCALE: As indicated
A201
Kenosha Brookside Care Center
3506 Washington Rd, Kenosha, WI 53144
#2518 - Kitchen Flooring Replacement
Floor Plan - Lower Level - Existing and Demo
July 17, 2025
3/16" = 1'-0"1 Floor Plan - Lower Level - Existing and Demo
DEMO GENERAL NOTES
EQUIPMENT STORAGE LOCATION
1 Addendum #1 08/13/2025
'�1
'�1
'�0
'�1
6'�4"
8"
5"
15'�7"
13'�6"
5" 6'�4"
12'�0"
5" 4'�6"
5" 7'�7"
45'�10"
'�0
'�1
'�1
�1
'�0
'�1
'�0
'�0
'�2
'�2
'�0
'�8
'�5
'�7
'�9
"5
'�7
'�0 kitchen dishwashing
09 91 00.A1
09 91 00.A1
09 91 00.A1
09 91 00.A1
09 91 00.A1
09 91 00.A1
09 91 00.A1
09 91 00.A1
09 91 00.A1
09 91 00.A2
09 91 00.A3
10 80 00.A1
09 91 00.A3
09 91 00.A3
09 91 00.A3
EXISTING
FREEZER
EXISTING
COOLER
EXISTING
COOLER
EXISTING
OFFICE
09 65 00.A2
09 65 00.A2
09 65 00.A2
(09 31 00) WA�� TI�E� REFER T�
SPECIFICATI��S
(09 31 00) F���R TI�E AS
SCHEDU�ED� REFER T�
SPECIFICATI��S
(07 92 13) SEA�A�T AT P�RCE�AI�
TI�E #�I�T, FU�� �E�GTH �F TI�E
(09 30 00) GR�UT #�I�T PRI�R T�
SEA�A�T
F���R STRUCTURE
EXISTI�G WA�� STRUCTURE
Room Schedule Notes:
1. ALTERNATE #1 - PROVIDE POLISHED CONCRETE FLOOR FINISH. WALL BASE UNDER ALTERNATE #1
TO BE STAINLESS STEEL WALL BASE
2. ALTERNATE #2 - PROVIDE TILE FLOORING; WALL BASE UNDER ALTERNATE #2 TO BE TILE WALL
BASE.
Room Schedule Notes:
1. ALTERNATE #3 - PAINT ALL EXISTING DRYWALL AREAS.
2. PAINT ALL EXISTING HM DOOR FRAMES AND EXISTING GUARDRAIL AREAS UNDER ALTERNATE #3.
3. PAINT ALL EXISTING TRENCH DRAIN GRATING IN THE BASE BID. COORDINATE ALL COLORS WITH
OWNER. GREEN REQUIRED AT TRENCH TIED TO GREASE INTERCEPTOR. RED FOR AREAS NOT
TIED IN WITH GREASE INTERCEPTOR.
(09 65 00) F���R FI�ISH PER
SCHEDU�ES A�D DETAI�S
(09 65 00) A�U'I�U'
PU�CTURE PR��F B��DED
REI�F�RCI�G STRIP
EXISTI�G F���R STRUCTURE
T� RE'AI� W� SE�F �EVE�I�G
C�'P�U�D
(09 65 00) STAI��ESS STEE� C�VE
CAP� VERIFY F���RI�G 'ATERIA�
THIC+�ESS
WA�� FI�ISH PER SCHEDU�ES A�D
DETAI�S
(07 92 13) C��T. SEA�A�T
8' � 0"
8' � 0"
8' � 0" kitchen dishwashing
AREA NOT IN SCOPE
AREA NOT IN SCOPE
09 91 00.A4
09 91 00.A4
09 91 00.A4
09 91 00.A4
09 91 00.A5
09 91 00.A6
09 91 00.A6
09 91 00.A5
09 91 00.A6
09 91 00.A5
09 91 00.A6
01 00 00.A8
01 00 00.A6
01 00 00.A7
(09 65 00) F���R FI�ISH PER
SCHEDU�ES A�D DETAI�S
EXISTI�G F���R STRUCTURE
T� RE'AI� W� SE�F �EVE�I�G
C�'P�U�D
REP�ACE DRYWA�� BEHI�D WA��
BASE AS REQUIRED F�R �EW WA��
BASE ADHESI��
WA�� FI�ISH PER SCHEDU�ES A�D
DETAI�S
EXISTI�G FRP �R GYPSU' WA��
(10 80 00) STAI��ESS STEE� WA��
BASE� 4" HEIGHT WITH T�E +IC+
3" = 1'-0"2 Wall Tile - Base Detail
H
OWNER:
PROJECT:
PROJECT
PROJECT ISSUE DATE:
©2025 Kueny Architects L.L.C. - All Rights Reserved
10505 Corporate Drive, Pleasant Prairie, WI 53158 phone: 262.857.8101 web: www.kuenyarch.com
A
1 2 3 4
1 2 3 4
X
B
C
D
X X
X
A
B
C
D
CONSULTANTS
REV # DESCRIPTION DATE
REVISIONS
KEY PLAN
PLAN NORTH
SHEET
SHEET TITLE:
ARCHITECT
Kueny Architects Phone: 262.857.8101 Address: 10505 Corporate Drive, Suite 100 Pleasant Prairie, Wisconsin 53158
Architect of Record - Jon P. Wallenkamp P:414.690.3197
Project Manager - Lee Anderson P:262.945.7709
KEYNOTE LEGEND
/1
/2
:4
:1
A
M
SCALE: As indicated
A202
Kenosha Brookside Care Center
3506 Washington Rd, Kenosha, WI 53144
#2518 - Kitchen Flooring Replacement
Floor Plan - Lower Level - Proposed
July 17, 2025
3/16" = 1'-0"1 Lower Level - Area H - Enlarged Kitchen
ROOM SCHEDULE
NUMBER NAME FLOOR TYPE BASE
WALL FINISH CEILING
NORTH SOUTH EAST WEST TYPE HEIGHT
037 .itche4 VI�Y� SHEET VI�Y� SHEET EXISTI�G EXISTI�G EXISTI�G EXISTI�G DRYWA�� 9'�0"
038 dishwashi4g VI�Y� SHEET VI�Y� SHEET EXISTI�G EXISTI�G EXISTI�G EXISTI�G DRYWA�� 9'�0"
01 00 00.A6 EXISTING LIGHT FIXTURES TO REMAIN
01 00 00.A7 EXISTING FIRE PROTECTION HEADS TO REMAIN
01 00 00.A8 EXISTING SPEAKERS TO REMAIN
09 65 00.A2 PROVIDE STAINLESS STEEL TRANSITION; MATCH EXISTING
PROFILE
09 91 00.A1 PAINT PER SPECIFICATIONS; RE-PAINT WALLS PER
ALTERNATE #3
09 91 00.A2 PAINT EXISTING DOOR FRAME AND WINDOW FRAME
09 91 00.A3 REPAIR EXISTING DOOR FRAME BASE AND PAINT PER SPECS
09 91 00.A4 PAINT EXISTING CEILING; COORDINATE WITH EXISTING
FIXTURES AND LIGHTING
09 91 00.A5 RE-PAINT EXISTING SUPPLY
09 91 00.A6 RE-PAINT EXISTING RETURN
10 80 00.A1 NEW EYE WASH STATION; SEE SPECIFICATIONS
PAINT SCHEDULE
ROOM
FLOOR
WALLS
CEILING METAL WOOD REMARKSNUM NAME NORTH SOUTH EAST WEST
037 .itche4 ��A PT�1 PT�1 PT�1 PT�1 PT�2 E�A'E� PT�1 RE�PAI�T A�� TRI' A�D EXISTI�G H' D��R FRA'ES
038 dishwashi4g ��A ��A ��A PT�1 PT�1 PT�2 E�A'E� PT�1 RE�PAI�T A�� EXISTI�G H' D��R FRA'ES
3" = 1'-0"3 Cove Base Detail
1/8" = 1'-0"4 Ceiling Plan - Kitchen
1 Addendum #1 08/13/2025
3" = 1'-0"5 Stainless Steel Base
| Brookside Care Center_2025 - Sheet - A202 - Floor Plan - Lower Level - Proposed.pdf |
| Sheets |
| A201 - Floor Plan - Lower Level - Existing and Demo |
| A202 - Floor Plan - Lower Level - Proposed |
| Brookside Care Center_2025 - Sheet - A201 - Floor Plan - Lower Level - Existing and Demo.pdf |
| Sheets |
| A201 - Floor Plan - Lower Level - Existing and Demo |
| A202 - Floor Plan - Lower Level - Proposed |
File details come from the government source that posted it. Updated .