25043-ITB-Kipnuk Transformers and H Piles Addendum #01.pdf

PDF 30 KB Posted

Attached to
Kipnuk Distribution System Upgrade Transformer and H-Pile Purchase
Solicitation number
25043
Issued by
Aleutians East Borough, Anchorage Municipality, Alaska

About this file

This document is an Addendum (No. 01) issued by the Alaska Energy Authority (AEA) for the Kipnuk Transformers and H Piles project, Solicitation No. RFQ 25043, dated April 1, 2025. The addendum provides clarification regarding the transformer specifications, specifically addressing a question about the 50kVA 3-phase transformer requirements. The document confirms that the request is for 3x 50kVA transformers, resulting in a 150kVA 3-phase bank, with transformers specified as 12470/7200 Grounded Wye and 208/120 Ground Wye configuration.

The addendum serves to modify the original Request for Quotes (RFQ) documents, ensuring all potential bidders have consistent and accurate information about the transformer specifications. It emphasizes that all other terms, conditions, and specifications of the original RFQ remain unchanged, and requires acknowledgment by email from plan holders. The clarification is critical for potential vendors to accurately quote and supply the correct transformer configuration for the Kipnuk Distribution System Upgrade project.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Page 1 of 1 Printed on 04/01/2025

Date: April 1, 2025 Project: Kipnuk Transformers and H Piles Solicitation No.: RFQ 25043 Addendum No.: 01

TO ALL PLAN HOLDERS:

The following changes, additions, clarifications, and/or deletions are hereby made a part of the RFQ Documents for the above noted project, fully and completely as if the same were fully contained therein. All other terms, conditions, and specifications of the original Request for Quotes remain unchanged.

This addendum must be acknowledged by email.

The modifications directed by this Addendum One are described on this page.

CHANGES TO DOCUMENTS:

The RFQ Package is hereby clarified, changed, or modified by the following:

1. Question: Would you please provide clarification about the 50kVA 3-phase transformer requested on RFQ 25043? Are they wanting 3x 50kVA (150kVA 3-phase bank) or expecting to make 50kVA total out of a 3-phase bank? The later alternative is highly unlikely b/c a manufacturer would have to custom engineer and produce 17.5kVA polemounts.

Answer: 3x 50kVA 150kVA 3-phase bank.

END OF ADDENDUM #01