25-8622_-_Exhibit_M_-_Final_Plans_20250723.pdf
PDF 5 MB Posted
- Attached to
- Ted Curcie Bridge Repair
- Solicitation number
- 25-8522
- Issued by
- Collier County, Florida
About this file
This is a Final Plans document prepared by Stantec Consulting Services for Collier County's Ted Curcie Bridge Repair project (Bridge No. 034122) located over a drainage canal in Naples, Florida. The project encompasses comprehensive bridge rehabilitation services including cathodic protection integral pile jacket systems for 16 piles across Bents 1-4, galvanic anode installations in End Bent 5, structural concrete spall repairs using latex-modified mortar, methacrylate monomer application to the bridge deck, and scour protection installation consisting of rubble riprap, bedding stone, and filter fabric. The plans specify detailed pay items including flowable fill for sheet pile walls (13.5 cubic yards), steel sheet piling permanent installation (2,000 square feet), bridge deck expansion joint rehabilitation (48 linear feet), riprap rubble for scour protection (209 tons), and bedding stone (140 tons). The design indicates a 60-foot overall bridge length with four 15-foot spans, a 24-foot roadway width, and 12-inch square prestressed concrete piles. The project requires compliance with Florida Department of Transportation Standard Specifications FY 2025-26, with elevations based on NAVD 88 datum and located in FEMA Flood Zone AE with a base flood elevation of 8.0 feet. Sealed bids are due October 2, 2025, at 3:00 p.m., with a non-mandatory pre-bid meeting scheduled for September 4, 2025, at 10:00 a.m.
The project timeline extends 270 calendar days total, with substantial completion required within 240 calendar days from the Notice to Proceed and final completion within 30 calendar days thereafter. Bidders must hold a State of Florida General Contractor or Building Contractor license and be FDOT Bridge Qualified, with at least one NACE-certified staff member required for cathodic protection work. The estimated construction budget is $873,723.54, requiring a 5% bid bond and performance and payment bonds for 100% of the contract amount. Liquidated damages of $1,685 per calendar day apply for failure to achieve substantial completion within the specified timeframe. Insurance requirements mandate $1,000,000 in commercial general liability and automobile liability coverage. Funding is provided directly by Collier County with no grant funding indicated. Work operations shall be confined to one traffic lane when necessary, with flaggers and traffic control devices required throughout construction. The contractor must maintain access for emergency vehicles and comply with Collier County road closure policies, obtain right-of-way permits, and coordinate with National Park Services for entrance gate access.
View the file
Other files
Show all 35
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
V:\2158\active\215811087\Bridge034122\4500209720\struct\KeySheet01.dgnmargarcia 7/21/2025 3:25:28 PM B-01
NO.
SHEET
YEAR
FISCAL
PERMIT PLANS
N
ENGINEER OF RECORD:
STRUCTURES PLANS
GOVERNING STANDARD SPECIFICATIONS:
http://www.fdot.gov/programmanagement/Implemented/SpecBooks for Road and Bridge Construction at the following website:
Florida Department of Transportation, FY 2025-26 Standard Specifications
GOVERNING STANDARD PLANS:
following website: http://www.fdot.gov/design/standardplans
Standard Plans for Road Construction and associated IRs are available at the
Bridge Construction and applicable Interim Revisions (IRs).
Florida Department of Transportation, FY 2025-26 Standard Plans for Road and
SHEET DESCRIPTIONSHEET NO.
INDEX OF STRUCTURES PLANS
CONTRACT PLANS COMPONENTS
BRIDGE NO. 034122 TED CURCIE ROAD OVER DRAINAGE CANAL
PROJECT LOCATION
EXPRESSWAY
T U
R N P
IK
E
PENSACOLA FORT WALTON
BEACH
PANAMA
CITY
CHIPLEY
TALLAHASSEE
JACKSONVILLE
ST AUGUSTINE
GAINESVILLE
OCALA DAYTONA BEACH
DELAND
NEW PORT RICHEY
TAMPA
LAKELAND
MELBOURNE -
COCOA
ORLANDO
BARTOWST PETERSBURG
SARASOTA -
BRADENTON
FT PIERCE
FT MYERS
WEST PALM
BEACH
FT LAUDERDALE
MIAMI
NAPLES
KEY WEST
CITY
LAKE
F
LO
R
ID
A 'S
BEACH LINE
https://goo.gl/maps/cEUVTcNYAaWp6yQ37
25 B-1
COLLIER COUNTY BOARD OF COMMISIONER:
WILLIAM L. MCDANIEL, JR.DISTRICT 5:
DAN KOWALDISTRICT 4:
BURT L. SAUNDERSDISTRICT 3:
CHRIS HALLDISTRICT 2:
RICK J. LOCASTRODISTRICT 1:
COLLIER COUNTY PROJECT MANAGER:
SENIOR PROJECT MANAGER
ROBERT WHITE, P.E., PMP
COLLIER COUNTY PROJECT NO.: 66066.2
STRUCTURE PLANS
BEGIN BRIDGE No.034122
BEGIN PROJECT
TO NAPLES
END BRIDGE No.034122
END PROJECT
TO MIAMI
VENDOR NO.: VF-112-167-170
CONTRACT NO. : 18-7432ST
PHONE: (561) 686-7707
WEST PALM BEACH, FLORIDA 33411
2056 VISTA PARKWAY, SUITE 100
STANTEC CONSULTING SERVICES, INC.
P.E. NO.: 65204
MOHIT SONI, P.E.
B1-10
B1-9
B1-8
B1-7
B1-6
B1-5
B1-4
B1-3
B1-2
B1-1
B-4
B-3
B-2
B-1
TEMPORARY TRAFFIC CONTROL PLAN
SCOUR PROTECTION DETAILS
SPALL REPAIR DETAILS
PILE JACKET DETAILS (3 OF 3)
PILE JACKET DETAILS (2 OF 3)
PILE JACKET DETAILS (1 OF 3)
FOUNDATION LAYOUT
TYPICAL SECTION THROUGH THE BRIDGE
BRIDGE HYDRAULIC RECOMMENDATIONS
PLAN AND ELEVATION
GENERAL NOTES
SUMMARY OF QUANTITIES
SIGNATURE SHEET
KEY SHEET
STATE OF
No 65204
R E
E
NI
GNE LANOIS
SE
F O
R P
ESNECIL
ADIROL
F
INOS TIHOM
STATE OF
No 71585
R E
E
NI
GNE LANOIS
SE
F O
R P
ESNECIL
ADIROL
F
ADNUMED DDOT
STATE OF
No 56859
R E
E
NI
GNE LANOIS
SE
F O
R P
ESNECIL
ADIROL
F
R
EI
E
MKCORB .E SI
R
H C
THE FOLLOWING SHEETS IN ACCORDANCE WITH RULE 61G15-23.004, F.A.C.
THE ABOVE NAMED PROFESSIONAL ENGINEER SHALL BE RESPONSIBLE FOR
SIGNED AND SEALED BY:
THIS ITEM HAS BEEN DIGITALLY
THE FOLLOWING SHEETS IN ACCORDANCE WITH RULE 61G15-23.004, F.A.C.
THE ABOVE NAMED PROFESSIONAL ENGINEER SHALL BE RESPONSIBLE FOR
SIGNED AND SEALED BY:
THIS ITEM HAS BEEN DIGITALLY
MOHIT SONI, P.E. NO. 65204
WEST PALM BEACH, FL 33411
2056 VISTA PARKWAY, SUITE 100
STANTEC CONSULTING SERVICES, INC.
ON ANY ELECTRONIC COPIES.
AND THE SIGNATURE MUST BE VERIFIED
NOT CONSIDERED SIGNED AND SEALED
PRINTED COPIES OF THIS DOCUMENT ARE
ON THE DATE ADJACENT TO THE SEAL
TODD DEMUNDA, P.E. NO. 71585
ROCKLEDGE, FL 32955
5445 VILLAGE DRIVE, SUITE 105
STANTEC CONSULTING SERVICES, INC.
ON ANY ELECTRONIC COPIES.
AND THE SIGNATURE MUST BE VERIFIED
NOT CONSIDERED SIGNED AND SEALED
PRINTED COPIES OF THIS DOCUMENT ARE
ON THE DATE ADJACENT TO THE SEAL
THE FOLLOWING SHEETS IN ACCORDANCE WITH RULE 61G15-23.004, F.A.C.
THE ABOVE NAMED PROFESSIONAL ENGINEER SHALL BE RESPONSIBLE FOR
SIGNED AND SEALED BY:
THIS ITEM HAS BEEN DIGITALLY
CHRIS E. BROCKMEIER, P.E. NO. 56859
NAPLES, FL 34105
3510 KRAFT ROAD, SUITE 200
STANTEC CONSULTING SERVICES, INC.
ON ANY ELECTRONIC COPIES.
AND THE SIGNATURE MUST BE VERIFIED
NOT CONSIDERED SIGNED AND SEALED
PRINTED COPIES OF THIS DOCUMENT ARE
ON THE DATE ADJACENT TO THE SEAL
SHEET NO. SHEET DESCRIPTION SHEET NO. SHEET DESCRIPTION
B-2
SIGNATURE SHEET
B1-2
B-2
BRIDGE HYDRAULIC RECOMMENDATIONS
SIGNATURE SHEET
SHEET NO. SHEET DESCRIPTION
TEMPORARY TRAFFIC CONTROL PLAN
SIGNATURE SHEET
B1-10
B-2
TEMPORARY TRAFFIC CONTROL PLAN
SCOUR PROTECTION DETAILS
SPALL REPAIR DETAILS
PILE JACKET DETAILS (3 OF 3)
PILE JACKET DETAILS (2 OF 3)
PILE JACKET DETAILS (1 OF 3)
FOUNDATION LAYOUT
TYPICAL SECTION THROUGH THE BRIDGE
PLAN AND ELEVATION
GENERAL NOTES
SUMMARY OF QUANTITIES
SUMMARY OF PAY ITEMS
SIGNATURE SHEET
KEY SHEET
B1-10
B1-9
B1-8
B1-7
B1-6
B1-5
B1-4
B1-3
B1-1
B-4
BQ1-1
B-3
B-2
B-1
MG 05/2021
AV 05/2021
REF. DWG. NO.
SHEET NO.
SHEET TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
DESIGNED BY:
CHECKED BY:
ROAD NO. COUNTY FINANCIAL PROJECT ID
REVISIONS
DATE BY DESCRIPTION DATE BY DESCRIPTION
margarcia 7/21/2025 V:\2158\active\215811087\Bridge034122\4500209720\struct\SIGNST.DGN
OG 05/2021
MG 05/2021
4500209720
3:25:59 PM
STANTEC CONSULTING SERVICES, INC.
P.E. License No. 65204
MOHIT SONI, P.E
WEST PALM BEACH, FLORIDA 33411
2056 VISTA PARKWAY, SUITE 100
COLIIER
TRANSPORTATION ENGINEERING DIVISION
COLLIER COUNTY
CR 92 TED CURCIE ROAD BRIDGE OVER DRAINAGE CANAL
SUMMARY OF EROSION AND SEDIMENT CONTROL DEVICES
LOCATION
SIDE
ID
AREA
BARRIER
TURBIDITY
FLOATING
NOTES
DESIGN
REMARKS
CONSTRUCTION
STA. TO STA.
0104 11
LF
P F
100.0 WEST SIDE OF BRIDGE
100.0 EAST SIDE OF BRIDGE
SUB-TOTAL: 200.0
TOTAL: 200
SUMMARY OF LUMP SUM ITEMS
NO.
PAY ITEM
PAY ITEM DESCRIPTION UNIT
QUANTITY
NOTES
DESIGN
REMARKS
CONSTRUCTION
P F
0101 1 MOBILIZATION LS 1
0102 1 MAINTENANCE OF TRAFFIC LS 1 14 DAYS PRIOR TO START
CONSTRUCTION THROUGH COMPLETION
0709 11101 TRAFFIC STRIPE-TWO REACTIVE COMPONENTS, LS 1 300 LF
STANDARD, WHITE, SOLID, 6"
0709 11201 TRAFFIC STRIPE-TWO REACTIVE COMPONENTS, LS 1 300 LF
STANDARD, YELLOW, SOLID, 6"
SUMMARY OF STRUCTURE QUANTITIES - BRIDGE 34122
SECTION
NO.
PAY ITEM
PAY ITEM DESCRIPTION LOCATION UNIT
QUANTITY TOTAL
NOTES
DESIGN
REMARKS
CONSTRUCTION
P F P F
0121 70 FLOWABLE FILL SHEET PILE WALLS CY 13.5 13.5
0401 70 2 RESTORE SPALLED AREAS, LATEX MODIFIED MORTAR-STYRENE BUTADINE BENT CAPS CF 2.2 3.2
DECK COPING CF 1.0
0413 151 METHACRYLATE MONOMER BRIDGE DECK GA 15.0 15.0
0413 154 CLEANING & SEALING CONCRETE SURFACES-PENETRANT SEALER OR METHACRYLATE BRIDGE DECK SF 1,441 1,441
0455 81 106 CATHODIC PROTECTION, F&I, PIER, OTHER MATERIAL ASSEMBLY BENT 5 EA 56 56
0455 133 3 STEEL SHEET PILING, F&I PERMANENT BEGIN/END BRIDGE SF 2,000 2,000
0457 2 211 CATHODIC PROTECTION INTEGRAL PILE JACKET, STRUCTURAL, UP TO 16", GALVANIC SYSTEM BENTS 1 THRU 4 LF 112 112
0458 1 28 BRIDGE DECK EXPANSION JOINT, REHABILITATION, POURED JOINT WITHOUT BACKER ROD BEGIN/END BRIDGE LF 48 48
0530 3 4 RIPRAP-RUBBLE. F&I, DITCH LINNING BEGIN/END BRIDGE TN 209 209
0530 74 BEDDING STONE BEGIN/END BRIDGE TN 140 140
MG 05/2021
AV 05/2021
REF. DWG. NO.
SHEET NO.
SHEET TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
DESIGNED BY:
CHECKED BY:
ROAD NO. COUNTY FINANCIAL PROJECT ID
margarcia 7/21/2025 V:\2158\active\215811087\Bridge034122\4500209720\struct\B1SumofQuantities01.DGN
4500209720
3:26:04 PM
T H
E O
F F
IC
IA
L R
E C
O R
D O
F T
H
IS
S H
E E
T I
S T
H E
E L
E C
T R
O N
IC
F
IL
E
D
IG
IT
A
L L
Y S
IG
N
E D
A N
D S
E A
L E
D U
N D
E R
R U
L E
G
-2
.0
F
.A .C
STANTEC CONSULTING SERVICES, INC.
P.E. License No. 65204
MOHIT SONI, P.E
COLLIER COUNTY
BRIDGE NO. 034122
CR 92
PAY ITEM NOTES:
SUMMARY OF QUANTITIES
B-3
UNIT PRICE OF PAY ITEM 455-133-3.
IS ENCOUNTER. PAYMENT FOR PRE-DRILLING SHALL BE INCLUDED IN THE
PRE-DRILLING TO INSTALL SHEET PILE MAY BE REQUIRED IF CAPROCK
UNIT PRICE OF PAY ITEM 455-133-3.
THE INSTALLATION OF STEEL SHEET PILE SHALL BE INCLUDED IN THE
FOR VEGETATION CLEANING AND/OR TRIMMING REQUIRED TO COMPLETE
5. ITEM NO. 455-133-3: STEEL SHEET PILING, F&I PERMANENT: PAYMENT
BE INCLUDED IN THE UNIT PRICE OF PAY ITEM 530-074.
COMPLETE THE INSTALLATION OF BEDDING STONE/FILTER FABRIC SHALL
PAYMENT FOR VEGETATION CLEANING AND/OR TRIMMING REQUIRED TO
UNIT PRICE FOR THIS PAY ITEM.
INSTALL BEDDING STONE/FILTER FABRIC SHALL BE INCLUDED IN THE
EXCAVATION, REMOVAL AND DISPOSAL OF EXISTING MATERIAL TO
4. ITEM NO. 530-074, BEDDING STONE:
UNIT PRICE FOR THIS PAY ITEM.
INSTALL THE PROPOSED SCOUR PROTECTION SHALL BE INCLUDED IN THE
FOR ANY REMOVAL OF EXISTING SAND-CEMENT RIPRAP REQUIRED TO
3. ITEM NO. 530-3-4, RIPRAP RUBBLE, F&I, DITCH LINNING: PAYMENT
ANODES ARE INCLUDED IN THIS PAY ITEM.
COST OF THE INTEGRAL CATHODIC PROTECTION PILE JACKET. THE BULK
CONTINUITY, CONDUIT, TERMINAL BOXES, ETC., IS INCIDENTAL TO THE
INSTALLATION SUCH AS POSITIVE AND NEGATIVE CONNECTIONS,
SERVICES, STEEL FOR NEW REBAR CAGE, ELECTRICAL WORK FOR JACKET
INCLUDED IN THE UNIT PRICE FOR THIS PAY ITEM. CP SPECIALIST'S
CATHODIC PROTECTION INTEGRAL PILE JACKET INSTALLATION SHALL BE
JACKET. PAYMENT FOR ANY REQUIRED EXCAVATION RELATED WITH THE
EXCAVATION MAY BE NEEDED AROUND THE PILE TO INSTALL PILE
2. ITEM NO. 457-2-211, CATHODIC PROTECTION INTEGRAL PILE JACKET:
SPILL ARE INCLUDED IN THIS PAY ITEM.
ABSORBENT MATERIALS EMPLOYED IN THE EVENT OF AN ACCIDENTAL
1. ITEM NO. 101-1: EROSION CONTROL DEVICES AND SKIMMERS OR
TED CURCIE ROAD BRIDGE OVER DRAINAGE CANAL
AV 05/2021
REF. DWG. NO.
SHEET NO.
SHEET TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
DESIGNED BY:
CHECKED BY:
ROAD NO. COUNTY FINANCIAL PROJECT ID
REVISIONS
margarcia 7/21/2025 V:\2158\active\215811087\Bridge034122\4500209720\struct\B1GeneralNotes01.dgn
4500209720
3:26:09 PM
T H
E O
F F
IC
IA
L R
E C
O R
D O
F T
H
IS
S H
E E
T I
S T
H E
E L
E C
T R
O N
IC
F
IL
E
D
IG
IT
A
L L
Y S
IG
N
E D
A N
D S
E A
L E
D U
N D
E R
R U
L E
G
-2
.0
F
.A .C
STANTEC CONSULTING SERVICES, INC.
P.E. License No. 65204
MOHIT SONI, P.E
COLLIER COUNTY
BRIDGE NO. 034122
CR 92
CALL 48 HOURS BEFORE YOU DIG
1-800-432 4770
SUNSHINE STATE ONE CALL OF FLORIDA, INC.
IT'S THE LAW !
UTILITIES NOTIFICATION CENTER
1-800-432-4770
Call 48 hours before you dig
One Call of Florida, Inc.
Sunshine State
GENERAL NOTES
DESIGN SPECIFICATIONS:
PLAN ELEVATIONS:
PLAN DIMENSIONS:
ENVIROMENTAL CLASSIFICATION:
UTILITIES:
EXISTING BRIDGE CONSTRUCTION CONSIDERATIONS:
BEGINNING CONSTRUCTION AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES
AND MAY NOT REPRESENT AS-BUILT CONDITIONS. VERIFY THIS DATA BEFORE
AS DETAILED IN THE ORIGINAL CONSTRUCTION PLANS OF THE EXISTING BRIDGE
ELEVATIONS AND INTERSECTION ANGLES SHOWN ARE BASED ON THE INFORMATION
DIMENSION VERIFICATION: UNLESS OTHERWISE NOTED, THE DIMENSIONS,
WATER QUALITY:
NAVIGATION:
CONCRETE CLASSES:
REINFORCING STEEL:
ALL REINFORCING STEEL SHALL BE ASTM A615, GRADE 60.
ACCIDENTAL SPILL.
MATERIALS AT THE WORK AREA FOR IMMEDIATE DEPLOYMENT IN THE EVENT OF AN
WORK AREA AT ALL TIMES. MAINTAIN APPROPRIATE SKIMMERS AND ABSORBENT
AVAILABLE MEANS OF EROSION AND TURBIDITY CONTROL MEASURES TO ISOLATE THE
THE DISCHARGE OF ANY FOREIGN MATERIAL INTO THE WATER. ERECT THE BEST
SHALL BE PERMITTED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PREVENTING
NO DEGRADATION OF WATER QUALITY AND/OR INCREASED TURBIDITY OF THE WATER
SHOULD THE WATERWAY BE CLOSED TO NAVIGATION.
EVENT OF HURRICANE WATCH/WARNING. AT NO TIME DURING THE CONSTRUCTION,
BEGINNING CONSTRUCTION AND SUBMIT A PLAN FOR CLEARING THE CHANNEL IN THE
MICHAEL LIEBERUM AT (305) 415-6744 SAFETY OFFICE THIRTY (30) DAYS PRIOR TO
CONTRACTOR SHALL NOTIFY THE UNITED STATES COAST GUARD MARINE COORDINATOR
THE WATERS WITHIN THE PROJECT AREA ARE FREQUENTED BY BOAT TRAFFIC. THE
SITE INSPECTION:
CONTACT
ENVIRONMENTAL NOTES:
".8
3 OF AGGREGATE FOR CLASS IV CONCRETE SHALL BE
EXISTING COVERS WILL BE MAINTAINED UNLESS OTHERWISE NOTED. MAX. SIZE
IV (SP 457) f'c = 5500 psi BENT PILES (JACKET)
POLYMER MODIFIED f'c = 6500 psi SPALL REPAIRS
CLASS MIN. 28-DAY COMP. STRENGTH LOCATION
SHOP DRAWING NOTES:
SPECIAL PROVISIONS.
JACKETS AND CONTINUITY TESTING OF REBARS AS NOTED IN THE TECHNICAL
OF THE OVERALL APPLICATION AND INSTALLATION OF THE CATHODIC PROTECTION
CERTIFIED CATHODIC PROTECTION (CP) SPECIALIST TO PROVIDE QUALITY ASSURANCE
THE CONTRACTOR SHALL SECURE THE SERVICES OF AN INDEPENDENT NACE
WITH THE CONTRACT DOCUMENTS.
ITEMS AND MATERIALS WHICH ARE REQUIRED TO BE FURNISHED IN ACCORDANCE
COMPENSATION WILL BE ALLOWED BECAUSE OF FAILURE TO INCLUDE IN BID ALL
NATURE OF THE WORK TO BE DONE UNDER THIS CONTRACT. NO EXTRA
FAMILIARIZED WITH THE PRESENT CONDITION AND TO JUDGE THE EXTENT AND
THE CONTRACTOR SHALL VISIT THE SITE BEFORE BIDDING TO BECOME
3. FDOT DESIGN MANUAL DATED JANUARY 2025.
9TH EDITION.
(AASHTO) LOAD AND RESISTANCE FACTOR (LRFD) BRIDGE DESIGN SPECIFICATIONS,
2. AMERICAN ASSOCIATION OF STATE HIGHWAY AND TRANSPORTATION OFFICIALS
DESIGN BULLETINS.
1. FDOT STRUCTURES MANUAL DATED JANUARY 2025 AND SUBSEQUENT STRUCTURES
239-656-2414 LEE COUNTY ELECTRIC CO-OP
407-722-2300 SUMMIT BROADBAND
239-252-1037 COLLIER COUNTY STAKE & LOCATES
239-822-7431 CENTURYLINK
TELEPHONE NO. UTILITY COMPANY
2. UTILITY OWNERS/AGENCY CONTACTS:
EFFORTS WITH UTILITY PROVIDERS.
PROTECTED FROM DAMAGE AS NECESSARY. CONTRACTOR SHALL COORDINATE ALL WORK
1. ALL EXISTING UTILITIES ARE TO REMAIN UNLESS OTHERWISE NOTED, AND
TOM BAIILEY
LESTER GUTHRIE
ERIC FEY
KENNY STINNETT
SCOPE OF WORK:
B-4
VERTICALLY UNLESS NOTED OTHERWISE.
ALL DIMENSIONS IN THESE PLANS ARE MEASURED EITHER HORIZONTALLY OR
SUBSTRUCTURE: EXTREMELY AGGRESSIVE
D. SCOUR PROTECTION
C. SPALL AND DELAMINATED AREAS OF CONCRETE COMPONENTS.
B. APPLICATION OF METHACRYLATE MONOMER TO BRIDGE DECK.
A. PILE JACKET SYSTEM WITH CATHODIC PROTECTION ON ALL PILES.
DOCUMENTS:
RESTORE AND/OR REPAIR THE FOLLOWING IN ACCORDANCE WITH THE CONTRACT
SCOUR PROTECTION SYSTEM).
CALCULATIONS (IF SELECTED IN LIEU OF THE CURRENTLY SHOWN RUBBLE RIPRAP
- ARTICULATED CONCRETE BLOCK REVETMENT SYSTEM (ACB) PLANS AND
E) SCOUR PROTECTION SYSTEM:
- PRODUCT DATA SHEET FOR THE SELECTED MATERIAL.
D) METACRYLATE MONOMER IN BRIDGE DECK:
- PRODUCT DATA SHEET FOR THE REPAIR MATERIAL.
C) RESTORE SPALL AREAS:
FOR REQUIREMENTS.
- REFER TO 66066.2-034122_TSP403_GALVANIC CATHODIC PROTECTION SYSTEM
B) GALVANIC CATHODIC PROTECTION SYSTEM:
- REFER TO 66066.2-034122_TSP457_CATHODIC PROTECTION FOR REQUIREMENTS.
A) CATHODIC PROTECTION INTEGRAL PILE JACKET:
SHOP DRAWINGS SHALL INCLUDE AND SHOW:
MAINTENANCE OF TRAFFIC:
SHEET.
FOR MAINTENANCE OF TRAFFIC, REFER TO TEMPORARY TRAFFIC CONTROL PLAN
REQUIREMENTS REGARDING ENDANGERED SPECIES.
THROUGH THE PROJECT AREA. COMPLY WITH ALL FEDERAL AND STATE
9. ENDANGERED MAMMALS, REPTILES, FISHES, AND BIRDS MAY MIGRATE
NOT PERMITTED.
BE TIED TO EXISTING PILES TO MAINTAIN POSITION. THE USE OF SPUDS IS
THE BRIDGE AS NECESSARY TO COMPLETE THE WORK. BOAT/PLATFORM MAY
8. SMALL WORK BOATS OR PLATFORMS OR FLOATS SHALL BE OPERATED UNDER
REPLACED PROMPTLY.
WETLAND AREAS THAT ARE DISTURBED DURING CONSTRUCTION ARE TO BE
INCIDENTAL IMPACTS SHOULD BE MINIMIZED AS MUCH AS POSSIBLE.
WETLANDS. WETLAND AREAS ARE TO BE AVOIDED AND PROTECTED. ANY
7. THERE IS NO WORK ANTICIPATED THAT WILL IMPACT THE EXISTING
6. THE WORK DOES NOT PROPOSE ANY DREDGING ACTIVITIES.
WETLANDS (MANGROVES) MAY REQUIRED FEDERAL AND/OR STATE PERMITS.
ENDANGERED SPECIES (MANATEES), AQUATIC RESOURCES (SEAGRASS) OR
AND WILDLIFE CONSERVATION COMMISION (FWC) IS REQUIRED. IMPACTS TO
THE EVERGLADES NATIONAL PARK COORDINATION WITH THE FLORIDA FISH
5. PLEASE BE ADVISED THAT IF THE PROJECT IS WITHIN THE BOUNDARIES OF
MATERIALS (ACM) AND ASBESTOS WAS NOT IDENTIFIED.
4. BRIDGE NO. 034122 HAS BEEN TESTED FOR ASBESTOS CONTAINING
SHALL BE PROTECTED BY APPROPRIATE EROSION CONTROL DEVICES.
3. ANY MATERIAL TO BE STOCKPILED FOR PERIODS GREATER THAN 24 HOURS
PERMITTED.
DISCHARGE OF ANY FOREIGN MATERIALS INTO THE WATER SHALL NOT BE
TURBIDITY UNITS (NTUS) ABOVE NATURAL BACKGROUND LEVELS. THE
CONTROL MECHANISMS ARE NOT ALLOWED TO EXCEED 29 NEPHELOMETRIC
2. THIS PROJECT CROSSES A WATERWAY, TURBIDITY LEVELS BEYOND THE
MAY OCCUR, CONTACT THE ENGINEER IMMEDIATELY.
OR IF A HAZARDOUS MATERIAL (INCLUDING SUSPECT ASBESTOS) RELEASE
HERBICIDES, ETC.) FROM SPILLING INTO THE SURFACE WATERS. IF A SPILL
TO PREVENT POTENTIAL POLLUTANTS (FUEL, LUBRICANTS,
WHAT MANAGEMENT PRACTICES AND CONTAINMENT METHODS WILL BE USED
CONTAINMENT, REPORTING, AND RESPONSE. THE CONTRACTOR SHALL SPECIFY
SPECIFICATION 104-5 THAT WILL INCLUDE TOXIC SUBSTANCE AND SPILL
1. PROVIDE THE COUNTY WITH AN EROSION CONTROL PLAN PER STANDARD
MANATEE CONDITIONS:
COMPLY WITH THE "STANDARD MANATEE CONDITIONS FOR IN-WATER WORK, 2011."
FEMA FLOOD:
FLOOD ELEVATION 8.0' (NAVD).
12021C0855J, DATED 02/08/2024, AND LOCATED IN FEMA FLOOD ZONE AE, BASE
THE SUBJECT PROPERTY IS LOCATED IN FEMA FLOOD INSURANCE MAP NUMBER
CONVERSION FORMULA : ELEV. (FT-NAVD 88) + 1.32' = ELEV. (FT-NGVD 29)
ON NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 88).
ELEVATIONS SHOWN ON THE PLANS WERE OBTAINED FROM SURVEY AND ARE BASED
TURBIDITY CONTROL:
MANAGEMENT PRACTICES SHALL BE UTILIZED THROUGHOUT CONSTRUCTION.
AS NECESSARY TO OPERATE WITH CURRENTS AT THE PROJECT SITE. BEST
WITH PERMIT REQUIREMENTS. TURBIDITY BARRIERS SHALL INCLUDE ANCHORS
CONTROL TURBIDITY CAUSED BY CONSTRUCTION OPERATIONS IN ACCORDANCE
PROVIDE AND MAINTAIN FLOATING TURBIDITY BARRIERS AS REQUIRED TO
BRIDGE NO. 034122
MG 05/2021
AV 05/2021
REF. DWG. NO.
SHEET NO.
SHEET TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
DESIGNED BY:
CHECKED BY:
ROAD NO. COUNTY FINANCIAL PROJECT ID
REVISIONS
margarcia 7/21/2025 V:\2158\active\215811087\Bridge034122\4500209720\struct\B1PlanElev01.dgn
4500209720
3:28:32 PM
T H
E O
F F
I C
I A
L R
E C
O R
D O
F T
H I S
S H
E E
T I
S T
H E
E L
E C
T R
O N
I C
F I L
E D
I G
I T
A L
L Y
S I G
N E
D A
N D
S E
A L
E D
U N
D E
R R
U L
E
G
.0
F
.A .C
STANTEC CONSULTING SERVICES, INC.
P.E. License No. 65204
MOHIT SONI, P.E
COLLIER COUNTY
BRIDGE NO. 034122
CR 92
N
¡ TED CURCIE ROAD
GUARDRAIL (TYP.)
END BENT 5
END BRIDGE
END BENT 1
BEGIN BRIDGE ¡ BENT 3¡ BENT 2 ¡ BENT 4
END BENT 1
BEGIN BRIDGE
END BENT 5
END BRIDGE
REFUGE
NATIONAL WILDLIFE
ACCESS GATE TO
90°00'00"
¡ BENT 2 ¡ BENT 3 ¡ BENT 4
REFUGE
WILDLIFE
TO NATIONAL
ACCESS GATE
(TYP.)
13'-0" MHC
ABANDONED IN PLACE
SHEET PILE TO BE
EXISTING
NOTES 4 AND 5 (TYP.)
SHEET PILE, SEE
PROPOSED
60'-0" (OVERALL BRIDGE LENGTH)
BARRIER (TYP.)
FLOATING TURBIDITY
EDGE OF WATER (TYP.)
(T Y
P
(O U
T T
O O
U T
C U
R B
C U
R B
CONC. PILE (TYP.)
PRESTRESSED
EXIST. 12" SQ.
CANAL
EXIST. BOTTOM OF
RIPRAP TO MATCH
TOP OF RUBBLE
SPECIFICATIONS SECTION 413
PER FDOT STANDARD
AND FROM BEGIN TO END BRIDGE
BRIDGE, FROM GUTTER TO GUTTER
THE ROADWAY DECK AREA OF THE
APPLY METACRYLATE MONOMER TO
EL. 6.53
LOW MEMBER
END BENT 5 PILES
JACKET IN ALL PILES EXCEPT
PROTECTION INTEGRAL PILE
INSTALL STRUCTURAL CATHODIC
TO REMAIN
CEMENT RIPRAP
EXIST. SAND
NOTES 4 AND 5
SHEET PILE, SEE
PROPOSED
RIPRAP (TYP.)
PROPOSED RUBBLE
LIMITS OF
SPAN 4
15'-0"
SPAN 3
15'-0"
SPAN 2
15'-0"
SPAN 1
15'-0"
RUBBLE RIPRAP
PROPOSED
TO BE ABANDONED
EXIST. SHEET PILE
ABANDONED IN PLACE
SHEET PILE TO BE
EXISTING
SHEET PILE
PROPOSED
SHEET PILE
PROPOSED
SHEET PILE
PROPOSED
RIPRAP TO REMAIN
EXIST. SAND CEMENT
C R
SEE NOTE 6
B1-1
PLAN AND ELEVATION
PLAN
ELEVATION
C A
N A
L
D R
A
IN
A G
E
AND LISTED ON THE APPROVED PRODUCT LIST (APL).
THE REQUIREMENTS OF SPECIFICATIONS SECTION 932
USE A TYPE D SILICONE SEALANT MATERIAL MEETING
RECOMMENDATIONS AND SPECIFICATIONS SECTION 458.
ACCORDANCE WITH MANUFACTURER'S
END OF BRIDGE, INSTALL POURED JOINT IN
9. CLEAN EXISTING EXPANSION JOINTS AT BEGIN AND
MUST BE APPROVED BY FDOT/PERMITTING AGENCIES.
EXISTING BOTTOM OF CANAL. THE USE OF ACB SYSTEM
RUBBLE RIPRAP). TOP OF ACB SYSTEM TO MATCH
PROTECTION SYSTEM (BEDDING STONE, FILTER FABRIC,
OF THE CURRENTLY SHOWN RUBBLE RIPRAP SLOPE
REVETMENT SYSTEM (ACB) MAY BE PROPOSED IN LIEU
8. AN EQUIVALENT ARTICULATED CONCRETE BLOCK
SHEET PILE.
BEDDING STONE/FILTER FABRIC, AND THE PROPOSED
REQUIRED TO COMPLETE THE INSTALLATION OF
7. VEGETATION CLEANING AND/OR TRIMMING MAY BE
FOUNDATION LAYOUT.
PILES, FOR ADDITIONAL INFORMATION REFER TO
IN END BENT 5 INSTALL DRILLED GALVANIC ANODES6.
171.7 IN^4/FT, MIN. SECTION MODULUS=25.65 IN^3/FT)
SECTION OR EQUIVALENT (MIN. MOMENT OF INERTIA =
5. PROPOSED SHEET PILE SECTION : NZ14 HOT ROLLED
BOTH END BRIDGE CORNERS.
EXISTING SHEET PILE AND PROPOSED SHEET PILE AT
WITH FLOWABLE FILL CONCRETE THE GAP BETWEEN
AFTERWARD OF THE EXISTING SHEET PILE WALL. FILL
4. PROPOSED SHEET PILE TO BE INSTALLED 12-INCHES
3. NO DREDGING IS PROPOSED.
MEASURED ALONG THE ¡ BRIDGE.
2. ALL DIMENSIONS WERE FIELD VERIFIED AND ARE
AVAILABLE.
1. EXISTING BRIDGE NO. 34122 PLANS ARE NOT
NOTES:
(TYP.)
MHW 0.69
MLW -1.92
2:1 2:1
2:1 2:1
C A
N A
L
D R
A
IN
A
PROPOSED SHEET PILE WALL = 80 LF
FLOWABLE FILL CONCRETE VOLUME = 13.5 CY
2. BELOW MHWL= 0.05582 ACRES
1. ABOVE MHWL = 0.00000 ACRES
AREA OF PROPOSED RIPRAP FILL:
-10
-5
EJ EJ
EL. -16.00 (TYP.)
SHEET PILE TIP
REF. DWG. NO.
SHEET NO.
SHEET TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
DESIGNED BY:
CHECKED BY:
ROAD NO. COUNTY FINANCIAL PROJECT ID
REVISIONS
margarcia 7/21/2025 V:\2158\active\215811087\Bridge034122\4500209720\struct\B1BridgeHydro01.dgn
4500209720
3:26:19 PM
T H
E O
F F
IC
IA
L R
E C
O R
D O
F T
H
IS
S H
E E
T I
S T
H E
E L
E C
T R
O N
IC
F
IL
E
D
IG
IT
A
L L
Y S
IG
N
E D
A N
D S
E A
L E
D U
N D
E R
R U
L E
G
-2
.0
F
.A .C
COLLIER COUNTY
BRIDGE NO. 034122
CR 92
1.9
.8
.6
.6
.2
.6
.5
.1
.5
.4
.8
1.0 - .5
.0
.4
.3
0.9- .4
.9
.2
.4
.3
( 3 ) ( 4 )
Greatest Flood: The most severe that can be predicted where overtopping is not practicable.
Overtopping Flood: Causes flow over the highway, over a watershed divide, or thru emergency relief structures.
Base Flood: Has a 1% chance of being exceeded in any given year (100 year frequency)
Design Flood: Utilized to assure a desired level of hydraulic performance.
SCOUR PREDICTIONS FOR PROPOSED STRUCTURE DESCRIBED ABOVE:
and land use. Users of this data are cautioned against the assumption of precision which cannot be obtained.
The resultant hydraulic data is sensitive to changes, particularly antecedent conditions, urbanization, channelization determined by a study of the watershed. Many judgements and assumptions are required to establish these factors.
elevations which may be anticipated in any given year. This data was generated using highly variable factors
The hydraulic data is shown for informational purposes only to indicate the flood discharges and water surface
(2)BRIDGE 34122
N
0 500
Feet
¡ TED CURCIE ROAD
PROFILE GRADE LINE
(TYP.)
EDGE OF WATER
END BENT 1
BEGIN BRIDGE
¡ PIER 2
¡ PIER 3
¡ PIER 4
END BENT 5
END BRIDGE
PROPOSED RUBBLE RIPRAP
BRIDGE LOCATION
SPAN 4
15'-0"
SPAN 3
15'-0"
SPAN 2
15'-0"
SPAN 1
15'-0"
BEGIN BRIDGE END BRIDGE
RUBBLE RIPRAP (TYP.)
LIMITS OF PROPOSED
60'-0" (OVERALL BRIDGE LENGTH)
CONC. PILE (TYP.)
PRESTRESSED
EXIST. 12" SQ.
LOW MEMBER EL. 6.53
STRUCTURE
PROPOSED
TERMS:
NOTE:
STAGE ELEV. NAVD (ft)
WATER SURFACE ELEVATIONS:
FLOOD DATA:
DISCHARGE (cfs)
AVERAGE VELOCITY (f/s)
EXCEEDANCE PROB. (%)
FREQUENCY (yr.)
N.H.W. (Non-Tidal)
CONTROL (Non-Tidal)
M.H.W. (Tidal)
M.L.W. (Tidal)
MAX. EVENT OF RECORD DESIGN FLOOD BASE FLOOD GREATEST FLOOD
OVERTOPPING or
TOTAL SCOUR ELEVATION
PIER INFORMATION LONG TERM
SCOUR ELEV.
WORST CASE < 100 yr.
FREQ. (yr.) FREQ. (yr.)
HYDRAULIC RECOMMENDATIONS
BEGIN BRIDGE STATION1.
2.
3.
4.
CLEARANCE PROVIDED:
MINIMUM CLEARANCE:
ABUTMENTS:
NAV: HORIZ.
NAV: HORIZ.
VERT.
VERT.
END BRIDGE STATION
ABOVE EL.
ABOVE EL.
DRIFT: HORIZ.
DRIFT: HORIZ.
VERT.
VERT.
ABOVE EL.
ABOVE EL.
END BRIDGEBEGIN BRIDGE
RUBBLE GRADE:
SLOPE:
BURIED OR NON-BURIED HORIZ. TOE:
TOE HORIZ. DISTANCE:
LIMIT OF PROTECTION:
DECK DRAINAGE:5.
REMARKS:
AREA OF OPENING@D.F.
HYDRAULIC DESIGN DATA
EXISTING STRUCTURES
SKEW ANGLE
SIZE AND TYPENUMBERS
ELEV. LOW MEMBER
BRIDGE WIDTH
TYPE CONSTRUCTION
SPAN LENGTH
OVERALL LENGTH
FOUNDATION
(REFERENCE)
WORST CASE < 500 yr.
6.53'
12" Sq. Conc. Piles
12" Sq. Conc. Piles
25'
5.84'
25.0' 2.00'
12" Sq. Conc. Piles
Prest. Conc. Slabs
1 %
4.5
6.1
X
BRIDGE NO. 34122
B1-2
BRIDGE HYDRAULIC RECOMMENDATIONS
24.00'
60.00'
15.00'
12" Sq. Conc. Piles
-30
-10
-40
-20
13.0'
DRAINAGE CONTAINED WITHIN CURBS, NO INLET OR SCUPPERS ARE PRESENT.
13'
BENT 3
BENTS 2 & 4
BENTS 1 & 5
N/A
N/A
N/A
-1.92
0.69
ELEVATIONS SHOWN ARE NAVD 88
5.84'
0°00'00"N/AN/A
6.00' 0.69
0.69 0.69
0.69
UNKNOWN
UNKNOWN
UNKNOWN
UNKNOWN
UNKNOWN
-8.7 (NAVD 88)
-8.3 (NAVD 88)
-7.9/-7.2 (NAVD 88)
12.0' TO EACH SIDE OF BRIDGE
N/A
NON-BURIED
MATCH EXIST. SLOPE
DITCH LINING
12.0' TO EACH SIDE OF BRIDGE
N/A
NON-BURIED
MATCH EXIST. SLOPE
DITCH LINING
STANTEC CONSULTING SERVICES, INC.
P.E. License No. 71585
TODD DEMUNDA, P.E
ROCKLEDGE, FLORIDA 32955
5445 VILLAGE DRIVE, SUITE 105
C A
N A
L
D R
A
IN
A
MLW -1.92
MHW 0.69
MATCH EXIST. BOTTOM OF CANAL
(*) TOP OF RUBBLE RIPRAP TO
PLAN
ELEVATION
REF. DWG. NO.
SHEET NO.
SHEET TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
DESIGNED BY:
CHECKED BY:
ROAD NO. COUNTY FINANCIAL PROJECT ID
REVISIONS
margarcia 7/21/2025 V:\2158\active\215811087\Bridge034122\4500209720\struct\B1BridgeSection01.dgn
4500209720
3:26:40 PM
T H
E O
F F
IC
IA
L R
E C
O R
D O
F T
H
IS
S H
E E
T I
S T
H E
E L
E C
T R
O N
IC
F
IL
E
D
IG
IT
A
L L
Y S
IG
N
E D
A N
D S
E A
L E
D U
N D
E R
R U
L E
G
-2
.0
F
.A .C
STANTEC CONSULTING SERVICES, INC.
P.E. License No. 65204
MOHIT SONI, P.E
COLLIER COUNTY
BRIDGE NO. 034122
CR 92
¡ BRIDGE & ROADWAY
CONCRETE PILE (TYP.)
12" SQ, PRESTRESSED
GUARDRAIL (TYP.)
W/ALUMINUM
" � PIPE 2
BOTTOM
EXIST. CHANNEL
24'-0"
1'-1" 1'-1"10'-11"10'-11"
PILE JACKET (TYP.)
PROTECTION INTEGRAL
STRUCTURAL CATHODIC
TYPICAL SECTION THROUGH THE BRIDGE
B1-3
MG 05/2021
AV 05/2021
REF. DWG. NO.
SHEET NO.
SHEET TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
DESIGNED BY:
CHECKED BY:
ROAD NO. COUNTY FINANCIAL PROJECT ID
REVISIONS
margarcia 7/21/2025 V:\2158\active\215811087\Bridge034122\4500209720\struct\B1FoundLay01.dgn
4500209720
3:26:44 PM
T H
E O
F F
IC
IA
L R
E C
O R
D O
F T
H
IS
S H
E E
T I
S T
H E
E L
E C
T R
O N
IC
F
IL
E
D
IG
IT
A
L L
Y S
IG
N
E D
A N
D S
E A
L E
D U
N D
E R
R U
L E
G
-2
.0
F
.A .C
STANTEC CONSULTING SERVICES, INC.
P.E. License No. 65204
MOHIT SONI, P.E
COLLIER COUNTY
BRIDGE NO. 034122
CR 92
N
ROAD
¡ TED CURCIE (TYP.)
90°00'00"
EDGE OF WATER
(TYP.)
EXIST. SHEET PILE
BARRIER (TYP.)
FLOATING TURBIDITY
PLAN
LEGEND:
#-# BENT ID - PILE ID
1-1
1-2
1-3
1-4
2-1
2-2
2-3
2-4
3-1
3-2
3-3
3-4
4-1
4-2
4-3
4-4
B1-4
FOUNDATION LAYOUT
5-1
5-2
5-3
5-4
EXISTING 12" SQ. PRESTRESSED CONCRETE PILE
C A
N A
L
D R
A
IN
A
NOTES:
STRUCTURAL CATHODIC PROTECTION INTEGRAL PILE JACKET (16 PILES TOTAL)
IN THE VERTICAL DIRECTION, TWO (2) ANODES PER ROW.
3. GALVANIC ANODES SHALL BE INSTALLED AT 8-INCHES SPACING
THE SPECIFICATIONS TSP403.
LENGTH EACH PILE) IN END BENT 5, IN ACCORDANCE WITH
EXPOSED SURFACE OF THE PILE (APPROXIMATELY 5-FEET
2. INSTALL DRILLED GALVANIC ANODES IN ALL PILES ALONG THE
ON EACH PILE, EXCLUDING END BENT 5 PILES.
1. INSTALL STRUCTURAL CATHODIC PROTECTION INTEGRAL JACKET
PROPRIETARY GALVANIC ANODE (4 PILES)
C R
REF. DWG. NO.
SHEET NO.
SHEET TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
DESIGNED BY:
CHECKED BY:
ROAD NO. COUNTY FINANCIAL PROJECT ID
REVISIONS
margarcia 7/21/2025 V:\2158\active\215811087\Bridge034122\4500209720\struct\B1MiscDet01.dgn
4500209720
3:26:50 PM
T H
E O
F F
IC
IA
L R
E C
O R
D O
F T
H
IS
S H
E E
T I
S T
H E
E L
E C
T R
O N
IC
F
IL
E
D
IG
IT
A
L L
Y S
IG
N
E D
A N
D S
E A
L E
D U
N D
E R
R U
L E
G
-2
.0
F
.A .C
STANTEC CONSULTING SERVICES, INC.
P.E. License No. 65204
MOHIT SONI, P.E
COLLIER COUNTY
BRIDGE NO. 034122
CR 92
45° CHAMFER
(PREINSTALLED IN JACKET)
NEW ZINC MESH ANODE
JACKET SEAM
HMWPE INSULATION (INSIDE JACKET)
NO. 8 AWG COPPER STRAND WIRE WITH
SIDES TO BULK ZINC ANODE
" � STEEL BAR WELDED ON BOTH 8
CONCRETE TYPE IV
JACKET FILLED WITH
NEW FIBERGLASS
SEE DETAIL A
PVC TERMINAL BOX
FACE OF EXIST. PILE
SEE NOTE 6
ACCESS PORT
MONITORING
AND DOWN TO THE TOP OF THE JACKET (TYP.)
JACKET, EMBED CONDUIT INTO THE CHAMFER
REQUIRED FOR ALL WIRES/CABLES OUTSIDE OF
" � OR SUITABLE SIZE PVC CONDUIT 4
REPAIR (FILL WITH APPROVED MORTAR)
4"X4" EXCAVATION FOR CONTINUITY
AND NOTE 3
SEE DETAIL B
" 6"6"
(HULL TYPE)
48 LB BULK ZINC ANODE
TORQUE TO 15 FT-LBS
AGAINST CONCRETE
STRAP, PLACE FLANGED SIDE
ANODE FOR FULL LENGTH INCLUDING
THICKNESS BOLTED TO BACK OF
" 16
32" GALVANIZED STEEL CHANNEL
48 LB. BULK ZINC ANODE
CARRIAGE BOLT
"Ø GALVANIZED8
AGAINST CONCRETE
FLANGED SIDE
THICKNESS, PLACE
" 16
3STEEL CHANNEL
2" GALVANIZED
EXCAVATED MUDLINE
EXISTING MUDLINE OR
M E
S H
H E
IG
H
T
M
IN
REMOVE AFTER THE FILL MATERIAL HAS SET
SEAL BOTTOM TO POUR FILLER MATERIAL,
FIBERGLASS FORM
FIBERGLASS FORM
BETWEEN ANODE MESH AND
CORNER OF JACKET. PLACE WIRE
TO STEEL BAR. ROUTE INTO
COPPER STRAND WIRE BRAZED
#8 HMWPE (RED INSULATION)
WELDED AT BOTH ENDS
" ROUND STEEL BAR8
48 LB. BULK ZINC ANODE
BULK ZINC ANODE WIRE
" DIA. PVC PIPE4
CP JACKET
PRE-INSTALLED ON INNER FACE OF FORM
ZINC ANODE MESH
TO ENCASE WIRE-BAR CONNECTION
" DIA. PVC FILLED WITH EPOXY 4
TO EXTEND A MAXIMUM OF 3" INSIDE JACKET
INSULATION DURING BRAZING OPERATION. CONDUIT
COPPER STRAND WIRE TO STEEL BAR AND PROTECT
NON-CONDUCTIVE EPOXY AFTER BRAZING. BRAZE
" Ø PVC PIPE. LOWER 8" TO BE FILLED WITH 4
J A
C K
E T
L E
N G
T H
AFTER FILLER MATERIAL HAS CURED
MATERIAL TO BE REMOVED
FORM TO POUR FILLER
ANODE ASSEMBLY, VIEW A-A)
BOTH ENDS (SEE BULK ZINC
BOLTED TO ANODE STRAP ON
STEEL CHANNEL
B1-5
PILE JACKET DETAILS (1 OF 3)
VIEW A-A
PILE JACKET NOTES
LEGEND
EXISTING STRUCTURAL ELEMENTS
NEW STRUCTURAL ELEMENTS
MHW EL
MLW EL
A
A
TYPICAL STRUCTURAL CATHODIC PILE JACKET
(NEW REINFORCEMENT NOT SHOWN FOR CLARITY)
TOP OF JACKET EL. +3.00
(¬) EXCAVATE MUDLINE WHERE NECESSARY
DETAIL B
4. FOR DETAIL A REFER TO PILE JACKET DETAILS (2 OF 3) SHEET.
A MINIMUM DEPTH OF 1'-0" BELOW THE JACKET.
3. AT LOCATIONS WHICH REQUIRE AN EXCAVATION, THE BULK ANODE MAY BE INSTALLED IN A HORIZONTAL POSITION AT
EAST FACE OF PILES WEST OF THE CHANNEL AND THE WEST FACE EAST OF THE CHANNEL.
2. ALL CONDUIT, BULK ZINC ANODES, MONITORING PORT, JUNCTION BOXES, AND CONNECTIONS SHALL BE PLACED ON THE
AND ON OPPOSITE SIDES WITH 3' MAXIMUM SPACING.
ARE REQUIRED TO ENSURE PROPER FILLING, THEY SHALL BE LOCATED ABOVE THE BOTTOM PORT HOLE STAGGERED
1. PROVIDE A PUMPING PORT WITHIN 4" OF THE PILE JACKET BOTTOM TO APPLY FILLER. IF ADDITIONAL PUMPING PORTS
CONTINUING TO OTHER PILE WORK.
8. SIMULTANEOUS PILE JACKET WORK SHALL BE INSTALLED, COMPLETED AND CURED FOR A MINIMUM OF 3 DAYS BEFORE
ADJACENT BENTS IS NOT PERMITTED.
7. NO ADJACENT PILES WITHIN THE SAME BENT SHALL BE REPAIRED SIMULTANEOUSLY. SIMULTANEOUS WORK ON
ACCESS PORTS ARE INSTALLED AT THE CORRECT LOCATION.
DESCRIBED IN THE SPECIAL PROVISIONS. VERIFY CURRENT MEAN HIGH WATER (MHW) TO ENSURE MONITORING
6. COMPLY WITH SPECIFICATIONS FOR WORK METHODS AND FILL MATERIAL. INSTALL MONITORING ACCESS PORTS AS
MUDLINE WHERE NECESSARY TO ACCOMPLISH PROPER PLACEMENT OF THE JACKET AND THE BULK ANODE.
5. INSTALL JACKET AND BULK ANODE PRIOR TO THE INSTALLATION OF ANY SCOUR MITIGATION SYSTEM. EXCAVATE
REF. DWG. NO.
SHEET NO.
SHEET TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
DESIGNED BY:
CHECKED BY:
ROAD NO. COUNTY FINANCIAL PROJECT ID
REVISIONS
margarcia 7/21/2025 V:\2158\active\215811087\Bridge034122\4500209720\struct\B1MiscDet02.dgn
4500209720
3:26:55 PM
T H
E O
F F
IC
IA
L R
E C
O R
D O
F T
H
IS
S H
E E
T I
S T
H E
E L
E C
T R
O N
IC
F
IL
E
D
IG
IT
A
L L
Y S
IG
N
E D
A N
D S
E A
L E
D U
N D
E R
R U
L E
G
-2
.0
F
.A .C
STANTEC CONSULTING SERVICES, INC.
P.E. License No. 65204
MOHIT SONI, P.E
COLLIER COUNTY
BRIDGE NO. 034122
CR 92
EXISTING STRAND (TYP.)
OUTSIDE JACKET FOR CLARITY)
NEGATIVE CONNECTIONS (SHOWN
CONTINUITY REPAIR OR
4"X4" EXCAVATION FOR
EXCAVATION RESULTING FROM
JACKET
EXISTING STRAND (TYP.)
PVC TERMINAL BOX
CHIPPING. SEE NOTE 1
SHALL BE ACHIEVED BY
" 4
1AND THEN THE LAST
" SHORT OF SPIRAL, 4
1STOP
PERIMETER, SAWCUT SHALL
SAWCUT AROUND ENTIRE
(M
IN
EXISTING SPIRAL
PERIMETER OF PILE
ON INNER FACE OF FORM
ZINC ANODE MESH PRE-INSTALLED
45° CHAMFER (TYP.)
ANODE MESH AND FIBERGLASS FORM
OF JACKET, PLACE WIRE BETWEEN
(RED INSULATION) ROUTED INTO CORNER
CONNECTION: ONE #8 AWG HMWPE
BULK ZINC ANODE POSITIVE
ORIGINATING AT LEFT HALF OF JACKET
ONE #10 AWG HMWPE (RED INSULATION)
ZINC ANODE MESH POSITIVE CONNECTION:
THE JACKET)
INTO THE CHAMFER DOWN TO THE TOP OF
CONNECTOR AND BUSHING. (EMBED CONDUIT
" DIA. SCH 80 WITH 4
1PVC CONDUIT. 1
CP JACKET (RIGHT HALF)
RING TERMINAL CONNECTOR
ANODE WIRE FROM BULK ANODE
" THREADED ROD4
1SS COUPLER FOR
ANODE WIRES FROM MESH IN JACKET
NEW STEEL CAGE
GROUND WIRES FROM
EXIST. PILE STEEL
GROUND WIRES FROM
TOGETHER
ALL WIRES SHORTED
BUS TERMINAL
CP JACKET (LEFT HALF)
SAME FACE AS THE TERMINAL BOX)
CP JACKET SEAM (LOCATE SEAM IN THE
TWO DIFFERENT BARS
WIRES BRAZED TO REINFORCING STEEL AT
#10 AWG HMWPE (WHITE INSULATION)
CAGE STEEL NEGATIVE CONNECTION: ONE
DIFFERENT LOCATIONS
WIRES BRAZED TO STEEL (TIES) AT TWO
ONE #10 AWG HMWPE (BLACK INSULATION)
EXISTING STEEL NEGATIVE CONNECTION:
ORIGINATING AT RIGHT HALF OF JACKET
ONE #10 AWG HMWPE (RED INSULATION)
ZINC ANODE MESH POSITIVE CONNECTION:
"2
SS NUT (TYP.)
SS WASHER (TYP.)
RUBBER WASHER (TYP.)
0.1 OHMs/2A SHUNT
THE JACKET) ATTACHED TO PILE
316 SS COVER SCREWS (WITHIN 1'-0" OF
PVC TERMINAL BOX (6"X6"X3" MIN. W/ TYPE
TIE AT TWO LOCATIONS
BRAZED TO A SPIRAL
SYSTEM NEGATIVES)
STRAND WIRES (FOR
NO. 10 AWG COPPER
PVC TERMINAL BOX
REACH PROPOSED
LONG ENOUGH TO
FREE END SHALL BE
BE AT LEAST 1" LONG
LENGTH TO
CONNECTION WELD
NEGATIVE CONNECTION,
CONNECTION ROD
ZINC MESH
CONNETCION ROD
GROUND
CONNECTION ROD
BULK ANODE
SS WASHERS AND NUT
THREAD, FULLY THREADED W/ TWO TYPE 316
"~20 4
1TYPE 316 SS HEX HEAD CAP SCREW,
THREE TYPE 316 SS WASHERS AND NUT
"~20 THREAD, FULLY THREADED W/ 4
TYPE 316 SS HEX HEAD CAP SCREW,
PILE JACKET DETAILS (2 OF 3)
B1-6
SCHEME 2SCHEME 1
ELEVATION
(SCHEME 2)
ELEVATION
(SCHEME 1)
TERMINAL BOX NOTES:
NOTES: DISCONTINUOUS STRAND. CONNECTIONS SHALL NOT TOUCH.
3. A MINIMUM OF TWO CONTINUITY CONNECTIONS SHALL BE MADE TO EACH
EPOXY. WIRES SHALL BE PARALLEL.
STRAND IS REACHED. COAT CONNECTION WITH 100% SOLID NON-CONDUCTIVE
DISCONTINUOUS STRAND TO THE ADJACENT STRAND UNTIL A CONTINUOUS
2. RESISTANCE WELD TWO NO. 10AWG OR LARGER MILD STEEL WIRES FROM ONE
SHOWN OUTSIDE JACKET FOR CLARITY.
APPROVAL OR PROPOSED SAWCUT LOCATION FROM ENGINEER. EXCAVATION
PILE JACKET DOES NOT EXTEND AT LEAST 7'-0" ABOVE MLW, OBTAIN
6'-0" ABOVE THE MLW AND A MAXIMUM OF 7'-0" ABOVE MLW. IN CASES WHERE
EXCAVATION AREA TO BE LOCATED INSIDE THE JACKET AT A MINIMUM OF
EXTENDS TO THE FIRST ADJACENT STRAND THAT IS CONTINUOUS.
1. EXCAVATE A 4"X4" AREA AT EACH STRAND OF DISCONTINUITY SUCH THAT IT
CONTINUITY CORRECTIONS
DETAIL A PVC TERMINAL BOX DETAIL
BE SEALED PRIOR TO PLACEMENT OF THE CATHODIC PROTECTION JACKET.
THE JACKET LIMITS. CONTINUITY TEST AND CONTINUITY CORRECTION EXCAVATIONS SHALL
POSSIBLE, ALL EXCAVATIONS TO EXPOSED REINFORCING STEEL SHALL BE MADE INSIDE
CORRECTIONS. AS LITTLE CONCRETE AS POSSIBLE SHALL BE REMOVED DURING REPAIR. IF
SUBMIT REPAIR PLANS SHOWING LOCATIONS AND SCHEME USED FOR CONTINUITY
3. NO STEEL FASTENERS SHALL BE USED INSIDE THE CP JACKET.
2. LOCATE CP JACKET SEAM IN THE SAME FACE AS THE TERMINAL BOX.
SCHEME 2.
REVEAL THAT DISCONTINUITY EXISTS IN THREE OR MORE STRANDS PER FACE, PERFORM
THAN TWO STRANDS PER FACE, PERFORM SCHEME 1. IF THE ELECTRICAL RESISTANCE TESTS
1. IF THE ELECTRICAL RESISTANCE TESTS REVEAL THAT DISCONTINUITY EXISTS IN NO MORE
" INCH OF LENGTH EXPOSED OUTSIDE THE BOX.2
1ALL THREADED RODS SHALL HAVE 113.
SO THAT ANIMALS AND INSPECTS CANNOT GET IN.
TWO WEEP HOLES SHALL BE PROVIDED AT THE BOTTOM WITH A MESH SCREEN COVER 12.
TERMINAL BOX SHALL BE WATERTIGHT.11.
SPECIALIST DURING ENERGIZATION.
ENDS OF THE GROUND THREADED ROD. IT SHALL ONLY BE CONNECTED BY THE CP
WHEN THE TERMINAL BOX IS INSTALLED, THE COUPLER SHALL NOT CONNECT THE TWO 10.
FASTENERS.
CONTACT ANY REINFORCEMENT IN THE PILE. USE EPOXY TO ISOLATE THE SS
316 STAINLESS STEEL FASTENERS. IF SS FASTENERS ARE USED, THEY MUST NOT
INSTALL THE TERMINAL BOX ON THE PILE USING EITHER NON-METALLIC FASTENERS OR 9.
ASSEMBLE THE TERMINAL BOX OFF-SITE AND DELIVER TO THE JOB SITE.8.
BETWEEN THEM.
ADJUST THE DISTANCE BETWEEN THE THREE THREADED RODS TO FIT THE SHUNT 7.
HALVES OF THE GROUND THREADED ROD DURING ENERGIZATION.
USE THE SS COUPLER TO CONNECT THE GROUND TO THE ANODES BY COUPLING THE TWO 6.
HMWPE INSULATION.
THE WIRES CONNECTING THE BUS TERMINAL TO THE THREADED RODS NEED NOT HAVE 5.
BOX.
USE ONLY 316 STAINLESS STEEL (SS) HARDWARE IN THE ASSEMBLY OF THE TERMINAL 4.
3. THE USE OF PVC TERMINAL BOXES WITH BRASS SCREW INSERTS IS NOT ALLOWED.
SEALER.
2. ALL PENETRATIONS IN THE PVC TERMINAL BOX SHALL BE SEALED WITH AN APPROVED
INHIBITOR.
1. ALL CONNECTIONS INSIDE THE PVC TERMINAL BOX SHALL BE COATED WITH A RUST
EACH DISCONTINUOUS STRAND. CONNECTIONS SHALL NOT TOUCH.
3. A MINIMUM OF TWO CONTINUITY CONNECTIONS SHALL BE MADE TO
EPOXY. WIRES SHALL BE PARALLEL.
STRANDS. COAT CONNECTION WITH 100% SOLID NON-CONDUCTIVE
2. RESISTANCE WELD NO. 10AWG OR LARGER MILD STEEL WIRES TO ALL
SAWCUTTING/CHIPPING AREA PER TSP 457.
APPROVAL OF PROPOSED SAW CUT LOCATION. CLEAN AND PREPARE
PILE JACKET DOES NOT EXTEND AT LEAST 7'-0" ABOVE MLW, OBTAIN
ABOVE MLW AND A MAXIMUM OF 7'-0" ABOVE MLW. IN CASES WHERE
AREA TO BE LOCATED INSIDE THE JACKET AT A MINIMUM OF 6'-0"
SAWCUTTING, CHIP AS NECESSARY TO EXPOSE STRANDS AND SPIRALS.
PERIMETER KEEPING CLEAR OF EXISTING STRANDS. AFTER
1. MAKE UNIFORM DEPTH AND HEIGHT SAW CUTS AROUND ENTIRE PILE
REF. DWG. NO.
SHEET NO.
SHEET TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
DESIGNED BY:
CHECKED BY:
ROAD NO. COUNTY FINANCIAL PROJECT ID
REVISIONS
margarcia 7/21/2025 V:\2158\active\215811087\Bridge034122\4500209720\struct\B1MiscDet03.dgn
4500209720
3:27:00 PM
T H
E O
F F
IC
IA
L R
E C
O R
D O
F T
H
IS
S H
E E
T I
S T
H E
E L
E C
T R
O N
IC
F
IL
E
D
IG
IT
A
L L
Y S
IG
N
E D
A N
D S
E A
L E
D U
N D
E R
R U
L E
G
-2
.0
F
.A .C
STANTEC CONSULTING SERVICES, INC.
P.E. License No. 65204
MOHIT SONI, P.E
COLLIER COUNTY
BRIDGE NO. 034122
CR 92
(TYP.)
6"
A T
E N
D S
C
L R
(T
Y P
1" CLR. MIN.
1'-6"
FACE, SEE DETAIL 1)
DOWEL (MIN. 8 PER
45° CHAMFER (SEE NOTE 3)
THREE EQ. SPA. AT EACH FACE
#7 BARS
APPROVED FILLER MATERIAL
INNER FACE OF FORM
PRE-INSTALLED ON
ZINC ANODE MESH
(ROUTED TO CORNER OF JACKET)
BULK ANODE WIRE
(OR EQUIVALENT) (TYP.)
FLAT BAR COLUMN CLAMPS
NEW #7 BAR
NEW #4 U-BAR
VERTICAL SPACING)
EPOXY (6'-0'' MAX.
BAR EMBEDDED IN
NEW #5 DOWEL CONCRETE PILE
EXISTING PRECAST
EXISTING STRAND
PILE SURFACE
NON-DAMAGED EXIST.
EMBEDMENT
4" MIN.
SEAL
TO REMAIN IN PLACE
FIBERGLASS FORMS
" THICK (MIN.)8
(TYP.) (CAGE STEEL)
@ 12" C/C
#4 U-BAR (PAIR)
(SEE NOTE 1) (TYP.)
WOOD STIFFBACKS
(CAGE STEEL)
#7 BARS (TYP.)
EXISTING PILE
CLAMP LOCATION (TYP.)
STANDOFFS AT EACH
CONCRETE PILE
EXISTING PRECAST
REMAIN IN PLACE
FIBERGLASS TO
TOP OF PILE JACKET
STRUCTURAL FIBERGLASS FORM)
" THICK (MIN.)8
1 (2'-0" X 2'-0" X
CATHODIC PROTECTION PILE JACKET
SEE DETAIL 1, NOTE 5
CONCRETE FILLER
REINFORCING STEEL
EXPOSED EXIST.
(TYP.) (CAGE STEEL)
#4 U-BAR (PAIR) @ 1'-0"
(TYP.)
3"
12"
PER SP 457
" MIN.4
J
A C
K E
T L
E N
G T
H
"2
(TYP.)
6"
A T
E N
D S
C
L R
(T
Y P
1" CLR. MIN.
1'-6"
FACE, SEE DETAIL 1)
DOWEL (MIN. 8 PER
45° CHAMFER (SEE NOTE 3)
THREE EQ. SPA. AT EACH FACE
#7 BARS
APPROVED FILLER MATERIAL
INNER FACE OF FORM
PRE-INSTALLED ON
ZINC ANODE MESH
(ROUTED TO CORNER OF JACKET)
BULK ANODE WIRE
(OR EQUIVALENT) (TYP.)
FLAT BAR COLUMN CLAMPS
NEW #7 BAR
NEW #4 U-BAR
VERTICAL SPACING)
EPOXY (6'-0'' MAX.
BAR EMBEDDED IN
NEW #5 DOWEL CONCRETE PILE
EXISTING PRECAST
EXISTING STRAND
PILE SURFACE
NON-DAMAGED EXIST.
EMBEDMENT
4" MIN.
SEAL
TO REMAIN IN PLACE
FIBERGLASS FORMS
" THICK (MIN.)8
(TYP.) (CAGE STEEL)
@ 12" C/C
#4 U-BAR (PAIR)
(SEE NOTE 1) (TYP.)
WOOD STIFFBACKS
(CAGE STEEL)
#7 BARS (TYP.)
EXISTING PILE
CLAMP LOCATION (TYP.)
STANDOFFS AT EACH
CONCRETE PILE
EXISTING PRECAST
REMAIN IN PLACE
FIBERGLASS TO
TOP OF PILE JACKET
STRUCTURAL FIBERGLASS FORM)
" THICK (MIN.)8
1 (2'-0" X 2'-0" X
CATHODIC PROTECTION PILE JACKET
SEE DETAIL 1, NOTE 5
CONCRETE FILLER
REINFORCING STEEL
EXPOSED EXIST.
(TYP.) (CAGE STEEL)
#4 U-BAR (PAIR) @ 1'-0"
(TYP.)
3"
12"
PER SP 457
" MIN.4
J
A C
K E
T L
E N
G T
H
"2
AA
(CATHODIC COMPONENTS NOT SHOWN FOR CLARITY)
PILE JACKET DETAILS (3 OF 3)
B1-7
LEGEND
SECTION A-A
#4 U-BAR
STRUCTURAL CATHODIC PILE JACKET DETAIL
NOTES:
EXISTING STRUCTURAL ELEMENT
NEW STRUCTURAL ELEMENT
DETAIL 1
DETAIL 1 NOTES:
ACCEPTED BY THE ENGINEER PRIOR TO BEGINNING ANY WORK.
4. ALL EXISTING PILE DIMENSIONS SHALL BE FIELD VERIFIED AND
REMOVED AND REPLACED AT THE DISCRETION OF THE ENGINEER.
CRACKS. IF CRACKING OCCURS, CHAMFER MATERIAL SHALL BE
3. JACKET CHAMFER SHALL HAVE A NEAT LINE AND BE FREE OF
457-3.2 OF THE FDOT SPECIFICATIONS.
2. SURFACE PREPARATION SHALL BE IN ACCORDANCE WITH SECTION
OR MISALIGNED. TO BE REMOVED AFTER CURING.
ON THE STANDOFFS HEADS SO THE FORM WILL NOT BE DEFORMED
1. PROVIDE HOLES IN THE WOOD STIFFBACKS TO RELIEVE PRESSURE
ROUTE TO TERMINAL BOX.
3. INSTALL TWO GROUND CONNECTIONS ON CAGE STEEL PER SECTION 457 OF THE SPECIFICATIONS AND
2. WIRE TIE ALL INTERSECTIONS OF VERTICAL BARS AND U-BARS.
JUNCTION BOX (SEE DETAIL A, PILE JACKET DETAILS (2 OF 3) SHEET).
1. PROVIDE ELECTRICAL CONTINUITY BETWEEN THE NEW AND EXISTING STEEL AT THE PVC TERMINAL
NOTES:
REINFORCING FOR JACKETS SHALL BE AS DETAILED ON THIS SHEET.
5. FILLER FOR JACKETS SHALL BE IN ACCORDANCE WITH FDOT SP 457.
MINIMUM COVER.
4. TRIM EXCESS LENGTH AFTER EMBEDMENT AS REQUIRED TO PROVIDE 1"
3. NO FLAME CUTTING OF REINFORCING STEEL WILL BE ALLOWED.
2. WIRE TIE ALL INTERSECTIONS OF DOWEL AND REINFORCING CAGE.
PILE REINFORCEMENT.
JACKET. MAINTAIN ELECTRICAL ISOLATION BETWEEN DOWEL AND EXISTING
WITH THE PILE LENGTH EXTENDING FROM THAT PARTICULAR END OF THE
AT A POINT WHERE STRAND AND CONCRETE IS INTACT AND CONTINUOUS
1. EMBED DOWEL WITH EPOXY, IN ACCORDANCE WITH SPECIFICATIONS 937,
TOP OF JACKET EL. 3.00
REINFORCING STEEL TO TERMINAL BOX
BULK ANODE, ANODE MESH AND
PVC CONDUIT TO ROUTE WIRES FROM
AA
(CATHODIC COMPONENTS NOT SHOWN FOR CLARITY)
PILE JACKET DETAILS (3 OF 3)
B1-7
LEGEND
SECTION A-A
#4 U-BAR
STRUCTURAL CATHODIC PILE JACKET DETAIL
NOTES:
EXISTING STRUCTURAL ELEMENT
NEW STRUCTURAL ELEMENT
DETAIL 1
DETAIL 1 NOTES:
ACCEPTED BY THE ENGINEER PRIOR TO BEGINNING ANY WORK.
4. ALL EXISTING PILE DIMENSIONS SHALL BE FIELD VERIFIED AND
REMOVED AND REPLACED AT THE DISCRETION OF THE ENGINEER.
CRACKS. IF CRACKING OCCURS, CHAMFER MATERIAL SHALL BE
3. JACKET CHAMFER SHALL HAVE A NEAT LINE AND BE FREE OF
457-3.2 OF THE FDOT SPECIFICATIONS.
2. SURFACE PREPARATION SHALL BE IN ACCORDANCE WITH SECTION
OR MISALIGNED. TO BE REMOVED AFTER CURING.
ON THE STANDOFFS HEADS SO THE FORM WILL NOT BE DEFORMED
1. PROVIDE HOLES IN THE WOOD STIFFBACKS TO RELIEVE PRESSURE
ROUTE TO TERMINAL BOX.
3. INSTALL TWO GROUND CONNECTIONS ON CAGE STEEL PER SECTION 457 OF THE SPECIFICATIONS AND
2. WIRE TIE ALL INTERSECTIONS OF VERTICAL BARS AND U-BARS.
JUNCTION BOX (SEE DETAIL A, PILE JACKET DETAILS (2 OF 3) SHEET).
1. PROVIDE ELECTRICAL CONTINUITY BETWEEN THE NEW AND EXISTING STEEL AT THE PVC TERMINAL
NOTES:
REINFORCING FOR JACKETS SHALL BE AS DETAILED ON THIS SHEET.
5. FILLER FOR JACKETS SHALL BE IN ACCORDANCE WITH FDOT SP 457.
MINIMUM COVER.
4. TRIM EXCESS LENGTH AFTER EMBEDMENT AS REQUIRED TO PROVIDE 1"
3. NO FLAME CUTTING OF REINFORCING STEEL WILL BE ALLOWED.
2. WIRE TIE ALL INTERSECTIONS OF DOWEL AND REINFORCING CAGE.
PILE REINFORCEMENT.
JACKET. MAINTAIN ELECTRICAL ISOLATION BETWEEN DOWEL AND EXISTING
WITH THE PILE LENGTH EXTENDING FROM THAT PARTICULAR END OF THE
AT A POINT WHERE STRAND AND CONCRETE IS INTACT AND CONTINUOUS
1. EMBED DOWEL WITH EPOXY, IN ACCORDANCE WITH SPECIFICATIONS 937,
TOP OF JACKET EL. 3.00
REINFORCING STEEL TO TERMINAL BOX
BULK ANODE, ANODE MESH AND
PVC CONDUIT TO ROUTE WIRES FROM
REF. DWG. NO.
SHEET NO.
SHEET TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
DESIGNED BY:
CHECKED BY:
ROAD NO. COUNTY FINANCIAL PROJECT ID
REVISIONS
margarcia 7/21/2025 V:\2158\active\215811087\Bridge034122\4500209720\struct\B1MiscDet04.dgn
4500209720
3:27:05 PM
T H
E O
F F
IC
IA
L R
E C
O R
D O
F T
H
IS
S H
E E
T I
S T
H E
E L
E C
T R
O N
IC
F
IL
E
D
IG
IT
A
L L
Y S
IG
N
E D
A N
D S
E A
L E
D U
N D
E R
R U
L E
G
-2
.0
F
.A .C
STANTEC CONSULTING SERVICES, INC.
P.E. License No. 65204
MOHIT SONI, P.E
COLLIER COUNTY
BRIDGE NO. 034122
CR 92
TYPE I
REPAIR
(VERTICAL)
TYPE III
REPAIR
(EXISTING) (PROPOSED)
CONCRETE SPALL
CONCRETE SPALL
EXIST. STIRRUP
EXIST. BAR
MORTAR/CONCRETE
PORTLAND CEMENT
PATCH W/ POLYMER MODIFIED
CUT EXISTING CONCRETE AND
CONCRETE SPALL REPAIR
TYPE III
REPAIR
SPALL REPAIR
CONCRETE
TYPE II
REPAIR
CONCRETE SPALL
CONCRETE SPALL REPAIR
MORTAR/CONCRETE
PORTLAND CEMENT
PATCH W/ POLYMER MODIFIED
CUT EXISTING CONCRETE AND
EXISTING MAIN REINFORCING
EXISTING STIRRUP
REINFORCING
EXIST. SLAB
CONC. DECK
MORTAR/CONCRETE
PORTLAND CEMENT
PATCH W/ POLYMER MODIFIED
CUT EXISTING CONCRETE AND
RECOMMENDED LAYOUT
B1-8
SPALL REPAIR DETAILS
REPAIR TYPE I
QTY
DETAIL - TYPICAL SPALL REPAIR CONFIGURATIONS
BENT CAP SPALL REPAIRS
BENT
(L x H x D)
DIMENSIONS
1 2'-0" x 1'-0" x 6" 1
TYPICAL BENT CAP SPALL REPAIRS
NOTES:
(SUPERSTRUCTURE SPAN AHEAD SHOWN, SPAN BACK NOT SHOWN FOR CLARITY)
LOCATION
1'-0" x 1-6" x 3"
1'-0" x 6" x 6"
EAST OVERHANG, TOP SIDE
WEST OVERHANG, BOTTOM SIDE
TYPE
REPAIR
I
I
III
QTYSPAN
(L x H x D)
DIMENSIONS
1 1
LOCATION
TYPE
REPAIR
II
DECK COPING SPALL REPAIRS
WEST SIDE 6" x 6" x 3"
WEST SIDE
EAST SIDE
6" x 6" x 3"
6" x 6" x 3"
II
II
WEST SIDE
EAST SIDE
6" x 6" x 3"
6" x 6" x 3"
II
II
REPAIR TYPE III
REPAIR TYPE II
EAST OVERHANG, BOTTOM SIDE
VERTICAL EDGE.
CONCRETE TO CURE FOR AT LEAST 72 HOURS BEFORE PROCEEDING TO REPAIR THE
DO NOT PERFORM REPAIRS SIMULTANEOUSLY. REPAIR TOP EDGES FIRST. ALLOW
BE INCLUDED IN THE UNIT PRICE OF PAY ITEM 401-70-2.
COST ASSOCIATED WITH THE SPALL REPAIR PROCESS DOCUMENTATION SHALL
2. SUBMIT PHOTOS TO THE COUNTY DOCUMENTING THE SPALL REPAIR PROCESS.
FIT LOCATION. EPOXY SHALL BE ON THE FDOT APPROVED PRODUCTS LIST.
LENGTH SHALL BE A MINIMUM OF 4" AND MAY REQUIRE TO BE FIELD-BENT TO
AND EPOXY INTO PLACE OR LAPPED WITH A LAP SPLICE OF 12". EMBEDED
BE REMOVED AND REPLACED WITH SAME SIZE BAR. NEW BAR CAN BE DRILLED
1. IF EXISTING REINFORCING EXHIBITS MORE THAN 20% SECTION LOSS, IT SHALL
REF. DWG. NO.
SHEET NO.
SHEET TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
DESIGNED BY:
CHECKED BY:
ROAD NO. COUNTY FINANCIAL PROJECT ID
REVISIONS
margarcia 7/21/2025 V:\2158\active\215811087\Bridge034122\4500209720\struct\B1ScourDetail01.dgn
4500209720
3:27:10 PM
T H
E O
F F
IC
IA
L R
E C
O R
D O
F T
H
IS
S H
E E
T I
S T
H E
E L
E C
T R
O N
IC
F
IL
E
D
IG
IT
A
L L
Y S
IG
N
E D
A N
D S
E A
L E
D U
N D
E R
R U
L E
G
-2
.0
F
.A .C
STANTEC CONSULTING SERVICES, INC.
P.E. License No. 65204
MOHIT SONI, P.E
COLLIER COUNTY
BRIDGE NO. 034122
CR 92
2T
FILTER FABRIC
BEDDING STONE
1'-0" MIN.
VARIES 1'-6" MIN.)
T (THICKNESS
2'-0" MIN.
BEDDING STONE
MIN.
1'-0"
6" TO TOP OF
TO ¡ SPLICE
6'-0" MIN.
SAND-CEMENT RIPRAP
CEMENT RIPRAP
DRIVEN THROUGH SAND-
#4 REBAR @ 1'-6" C/C
RUBBLE RIPRAP
(TYP.)
SPLICE
FABRIC
FILTER
CONCRETE PILE (TYP.)
PRESTRESSED
EXIST. 12" SQ.
BEDDING STONE
1'-0" MIN.
BERM
3'-0" MIN.
PILE
ELEVATION AT FACE OF
MATCH EXIST. RIPRAP
TOP OF BERM TO
RIPRAP TO REAMIN
EXIST. SAND-CEMENT
FABRIC
INSTALLATION OF THE FILTER
COATING IMMEDIATELY PRIOR TO
FILTER FABRIC WITH BITUMINOUS
(*) COAT AREA BETWEEN PILE AND
2T
BEDDING STONE
1'-0" MIN.
BOTTOM OF CHANNEL
TO MATCH EXIST.
TOP OF RUBBLE RIPRAP
FABRIC
FILTER
VARIES) (1'-6" MIN.)
T (THICKNESS
FABRIC
FILTER
BEDDING STONE
BETWEEN PILES, TO REMAIN
RIPRAP PLACED VERTICALLY
EXISTING SAND-CEMENT
AGENCIES.
ACB SYSTEM MUST BE APPROVED BY FDOT/PERMITTING
TO MATCH EXISTING BOTTOM OF CANAL. THE USE OF EQUIVALENT
STONE, FILTER FABRIC, RUBBLE RIPRAP). TOP OF ACB SYSTEM
SHOWN RUBBLE RIP RAP SLOPE PROTECTION SYSTEM (BEDDING
SYSTEM (ACB) MAY BE PROPOSED IN LIEU OF THE CURRENTLY
3. AN EQUIVALENT ARTICULATED CONCRETE BLOCK REVETMENT
IN THE UNIT PRICE OF PAY ITEM 530-074.
COST ASSOCIATED WITH CHANNEL SURVEY SHALL BE INCLUDED
B. AFTER INSTALLATION OF PROPOSED SCOUR PROTECTION.
A. PRIOR TO INSTALLATION OF PROPOSED SCOUR PROTECTION,
2. PERFORM CHANNEL SURVEY AS FOLLOWS:
ACCORDANCE WITH SPECIFICATIONS SECTION 514.
SPECIFICATIONS SECTION 985. SPLICE LENGTH SHALL BE IN
1. FILTER FABRIC SHALL BE TYPE D-2, IN ACCORDANCE WITH
CONC. PILE
PRESTRESSED
EXIST. 12" SQ.
VARIES 1'-6" MIN.)
T (THICKNESS
CHANNEL
EXIST. BOTTOM OF
CHANNEL (MATCH)
EXIST. BOTTOM OF
RIPRAP TO REAMIN
EXIST. SAND-CEMENT
2T
NOTES:
MLW
1'-0" (MIN.) TRENCH BELOW
EMBED REBAR
RIPRAP
SAND-CEMENT
SCOUR PROTECTION DETAILS
TYPICAL SECTION TROUGH ¡ BRIDGE
B1-9
TYPICAL DETAIL AROUND PILES TYPICAL END SECTION ALONG CANAL
A e c c
D b
C o g o
P o in t
(A e c c
La n d
A e c c
D b
C o g o
P o in t
(A e c c
La n d
A e c c
D b
C o g o
P o in t
(A e c c
La n d
A e c c
D b
C o g o
P o in t
(A e c c
La n d
WORK AREA
85' (BN 034122)
200' 200'
155'
12 13 14 14+21
100'245'
SYMBOLS:
WORK AREA
GENERAL NOTES:
N
LANE IDENTIFICATION & DIRECTION OF TRAFFIC
CHANNELIZING DEVICE (SEE INDEX NO. 102-600)
WORK ZONE SIGN
END
ROAD WORK
W20-4
FLAGGER
W20-7
W20-1F G20-2
MOT-13-06
SPEEDING FINES
DOUBLED
WHEN WORKERS
PRESENT
AHEAD
WORK
ROAD
AHEAD
ROAD
ONE LANE
END
ROAD WORK
TED CURCIE ROAD
PHASE I
DEVICES IS 50'.
SPACING BETWEEN CHANNELIZING
OPPOSITE HAND)
- EASTBOUND LANE -CURCIE ROAD / SOUTHBOUND LANE CR 92 SIMILAR BUT
(WESTBOUND CURCIE ROAD / NORTHBOUND LANE - CR 92 DIRECTION SHOWN
(PHASE II AS MODIFIED IN NOTES BELOW)
W20-1F
AHEAD
WORK
ROAD
TYPE III BARRICADE
C R
W20-4
AHEAD
ROAD
ONE LANE
W20-7
G20-2
CHANNELIZING DEVICES IS 25'.
SPACING BETWEEN
(BUFFER)(TAPER)
G20-2
END
ROAD WORK
W20-1F
AHEAD
WORK
ROAD
MOT-13-06
SPEEDING FINES
DOUBLED
WHEN WORKERS
PRESENT
W20-4
AHEAD
ROAD
ONE LANE
W20-7
24" WHITE LINE
24" WHITE LINE
24" WHITE LINE
0 40' 80'
B1-10
SN 05/2021
AM 05/2021
REF. DWG. NO.
SHEET NO.
SHEET TITLE:
PROJECT NAME:
DRAWN BY:
CHECKED BY:
DESIGNED BY:
CHECKED BY:
ROAD NO. COUNTY PROJECT ID
COLLIER COUNTY
CH 07/2021
DH 07/2021
4500209720 COLLIER CR 92
TEMPORARY TRAFFIC CONTROL PLAN STANTEC CONSULTING SERVICES, INC.
CHRIS E. BROCKMEIER, P.E.
P.E. LICENSE NO. 80986
NAPLES, FL. 34105
3510 KRAFT ROAD, SUITE 200
T H
E O
F F
IC
IA
L R
E C
O R
D O
F T
H
IS
S H
E E
T I S
T H
E E
L E
C T
R O
N
IC
F
IL
E D
IG
IT
A L L Y
S
IG
N E
D A
N D
S E
A L E
D U
N D
E R
R U
L E
G
-2
.0
F
.A .C margarcia 5/8/2025 5:13:04 PM V:\2158\active\215811087\Bridge034122\4500209720\trafops\11087-01c-tc02-Ted Curcie-Binded-10.dgn
CONSTRUCTION.
BE APPLIED IN ACCORDANCE TO FDOT REQUIREMENTS AND RECOMMENDATIONS PER SECTION 709 OF THE STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE PAVEMENT MARKING MATERIAL SHALL BE TWO COMPONENT REACTIVE MARKINGS AND MATCH THE EXISTING COLOR, TYPE, AND SIZE. PAVEMENT MARKINGS SHALL
THE CONTRACT. CONTRACTOR SHALL REPLACE PAVEMENT MARKINGS WITHIN THE BRIDGE DECK CONSTRUCTION LIMITS PRIOR TO SUBSTANTIAL COMPLETION OF 13.
SIGNS TO BE COVERED WHEN NOT IN USE FOR ACTIVE LANE CLOSURE OPERATION.12.
WORK ZONE POSTED SPEED: 30 MPH
CR 92 ROAD POSTED SPEED: 45 MPH.
CURSIE ROAD POSTED SPEED: 30 MPH.11.
CONTRACTOR IS REQUIRED TO COMPLY WITH COLLIER'S COUNTY ROAD LANE CLOSURE POLICIES, AND OBTAIN REQUIRED ROW PERMITS.10.
FT.WHEN BUFFER SPACE CANNOT BE ATTAINED DUE TO GEOMETRIC CONSTRAINTS, USE THE GREATEST ATTAINABLE LENGTH, NOT LESS THAN 155 9.
LOCATION OF FLAGGERS AND FLAGGER SIGNS SHALL BE IN ACCORDANCE WITH FDOT DESIGN STANDARDS INDEX 102-603.
FLAGGERS ARE THE SOLE MEANS OF ONE-WAY CONTROL, THE FLAGGERS MUST BE IN SIGHT OF EACH OTHER OR IN DIRECT COMMUNICATION AT ALL TIMES.
8. FLAGGERS MAINTENANCE OPERATIONS SHALL BE IMPLEMENTED TO THE TEMPORARY TRAFFIC CONTROL THROUGHOUT THE PROJECT LIMITS, AS NECESSARY. WHEN
7. CONTRACTOR SHALL MAINTAIN A DRIVABLE ROADWAY SURFACE TO PROVIDE ACCESS TO LOCAL AND EMERGENCY VEHICLES AT ALL TIMES OF THE DAY.
KEY CONTACT INFORMATION AND APPROVAL OF CONTRACTOR TO UTILIZING PART OF THE PROPERTY FOR STAGING / LAYDOWN AREA AS PART OF THE PROJECT.
ENTRANCE GATE CONTRACTOR SHALL COORDINATE WITH COLLIER COUNTY AND NATIONAL PARK SERVICES PRIOR TO COMMENCING CONSTRUCTION TO VERIFY 6.
PUBLIC ACCESS TO BUSINESSES, RESIDENCES, AND SIDE STREETS SHALL BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION.5.
FOR GENERAL TRAFFIC CONTROL ZONE REQUIREMENTS AND ADDITIONAL INFORMATION REFER TO INDEX NO. 102-600, 102-603 AND 102-604.4.
ROTATING, FLASHING, OSCILLATING, OR STROBE LIGHTS OPERATING.
HIGH- INTENSITY THE TWO CHANNELIZING DEVICES DIRECTLY IN FRONT OF THE WORK AREA MAY BE OMITTED PROVIDING VEHICLES IN THE WORK AREA HAVE 3.
CONTRACTOR SHALL NOTIFY THE COLLIER COUNTY ENGINEER A MINIMUM OF TWO WEEKS IN ADVANCE OF ANY LANE CLOSURES.2.
WORK THAT IS TO BE PERFORMED FROM THE WATERWAY, THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ACCESS VIA PUBLIC OR PRIVATE BOAT RAMP.
CONFINED TO PILE JACKETING SYSTEM WITH CATHODIC PROTECTION ON ALL PILES, AND APPLICATION OF METHACRYLATE MONOMER TO BRIDGE DECK. FOR
OPERATIONS ARE WORK OPERATIONS SHALL BE CONFINED TO ONE TRAFFIC LANE WHEN NECESSARY, LEAVING THE ADJACENT LANE…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .