This document is a set of engineering plans prepared by Endeavor Civil Engineering Inc. for the Iowa Department of Natural Resources septic mound system project at Wapsipinicon State Park in Jones County, Iowa. The project involves the demolition of an existing septic system and installation of a new mound-based wastewater treatment system. Key project components include installing a 2,000-gallon septic tank, a 1,000-gallon dosing chamber with pump, 290 feet of 2-inch diameter force main pipe, seven distribution trenches measuring 2 feet wide by 75 feet long spaced 4 feet apart, and associated site work including removal of the existing septic tank and installation of sewer service lines. The mound system measures 156 feet by 32 feet and will be constructed with sand fill material, synthetic drainage fabric, and a topsoil cap. The project location is within the park near an existing restroom facility, with specific considerations for maintaining 100-foot separation from a private irrigation well and minimal disturbance to golf course operations. Bid closing is scheduled for August 27, 2026 at 3:00 PM, with electronic submission required.

The plans specify material requirements compliant with Iowa Code Chapter 69, including detailed cross-sectional specifications for distribution trenches with gravel placement at minimum 6 inches below and 2 inches above distribution pipes. All disturbed areas must be hydroseeded and fertilized with native topsoil blended into existing hillside slopes. Site-specific requirements include cutting a gap in existing cable fencing to provide improved access from the golf course and installing matching posts to maintain fencing integrity. Cleanout locations on distribution runs must be installed flush with ground surface with threaded caps and green lids suitable for golf course mowing operations to minimize operational disruption.

View the file

Other files

File Type Posted
25-06-53-01 - Bid Package.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

IOWA DEPARTMENT OF

NATURAL RESOURCES

SEPTIC MOUND SYSTEM

S E

P T

IC

M

O U

N D

S Y

ST

E

M

IO

W A

D E

P A

R T

M E

N T

O F

N A

T U

R A

L R

E S

O U

R C

E S

IOWA

ONE CALL

800 / 292-8989

TOLL FREE

CALL - BEFORE - YOU - DIG

I hereby certify that this engineering document was prepared by me or under my direct supervision and that I am a duly licensed Professional Engineer under the laws of the State of Iowa.

ENDEAVOR CIVIL ENGINEERING INC.

1 TITLE SHEET

2 ESTIMATE OF QUANTITIES AND GENERAL NOTES

3 MISCELLANEOUS NOTES AND SPECIFICATIONS

4 SITE LOCATION

5 SITE PLAN VIEW

6 MOUND SYSTEM LAYOUT AND DETAILS

SH

AW

RD

228 A V

E

GRANT WOOD RD

120 ST

SLIDE ROCK RD

150 ST

138 ST

A V

E

C O

R D

E

SLIDE ROCK RD

SHOOTING STAR RD

150 ST

FOREST

CHAPEL RD

205 AVE

D

EA

R B

O

RN

R D

STONECITY RD

ANAMOSA

F A I R V I E W

CO HOME RD E23

RID

G

E RD E28

ST

O

NE C

ITY

R D X

‒‒0

8/11/2026

Mike Typewritten Text Michael Dufoe, P.E.

Mike Typewritten Text Bruce Flippin, P.E.

REF.# DESCRIPTION

Endeavor Civil Engineering

GENERAL NOTES

Mike Text Box

See Attachment B as part of Contract and Proposal Bid Documents for Quantity Information

SEPTIC TANK

DOSING CHAMBER

MOUND FILL MATERIAL

MOUND GRAVEL MATERIAL

PROJECT LOCATION WITHIN PARK

WAPSIPINICON STATE PARK

INSTALL 2,000 GALLON

SEPTIC TANK

INSTALL 1,000 GALLON

DOSING CHAMBER

WITH PUMP

EXISTING RESTROOM

FACILITY

PROPOSED MOUND SYSTEM LOCATION

DIMENSIONS: 156.0' x 32.0'

(SEE SHEET 6 FOR ADDITIONAL DETAILS)

INSTALL 290 FEET OF 2" DIA. SDR 26 OR STRONGER

SANITARY SEWER FORCE MAIN PIPE, BORE PIPE IN

AREAS OUTSIDE OF MOUND WHERE POSSIBLE TO

MINIMIZE DISTURBANCE. PIPE SHALL ALSO HAVE A

POSITIVE SLOPE TO IT TO ALLOW EFFLUENT TO

BACKFLOW INTO DOSING CHAMBER BETWEEN

PUMPINGS

REMOVE EXISTING

SEPTIC TANK

75' LONG RUNS OF 1" DIAMETER

SDR26 IN 2 FOOT TRENCHES (SEE

SHEET 6 FOR ADDITIONAL DETAILS)

INSTALL 15 FEET OF 4" DIA. SDR 26

OR STRONGER SEWER SERVICE AT

A MIN. 1% SLOPE

MAINTAIN MINIMUM OF 10 FOOT

SEPARATION BETWEEN EDGE OF

MOUND SYSTEM AND WATER

IRRIGATION LINE

INSTALL 5 FEET OF 4" DIA. SDR 26

OR STRONGER SEWER SERVICE AT

A MIN. 1% SLOPE

783 785

HYDROSEED, AND FERTILIZE OVER ALL

DISTURBED AREAS.

BLEND TOP SOIL COVER INTO

EXISTING HILL SIDE SURROUNDING

MOUND SYSTEM DISTRIBUTION

AREA

IRRIGATION LINE

IRRIGATION LINE

IRRIGATION LINE

IR

RI

GAT

IO

N LI

NE

PRIVATE IRRIGATION WELL

EDGE OF MOUND AREA IS 101' AWAY FROM

IRRIGATION WELL. MAINTAIN MINIMUM

100' SEPARATION DURING CONSTRUCTION

CONTRACTOR TO CUT GAP IN EXISTING CABLE FENCE AT

LOCATION DETERMINED SUITABLE BY THE DNR TO

PROVIDE BETTER ACCESS TO RESTROOM FACILITY FROM

THE GOLF COURSE. A NEW POST MATCHING THE

EXISTING POSTS SHALL BE INSTALLED 3.5' FROM AN

EXISTING POST IN THE GAP TO RE-ATTACH THE CABLE TO

FOR PEDESTRIAN ACCESS.

Mike Polygonal Line

Mike Typewritten Text

SENSATIVE AREA

AVOID

CAP SYSTEM WITH 12

INCHES OF TOP SOIL

BLEND ENDS OF

TOPSOIL LAYER INTO

EXISTING HILL SLOPE

SAND FILL MATERIAL

LAYER: 2.25' THICK

2' WIDE DISTRIBUTION

TRENCHES

RESTRICTIVE LAYER

PLOWED SURFACE

SHAPE ENDS TO AT

LEAST 3:1 SLOPE

1" DIA. DISTRIBUTION PIPE

4 FOOT SPACING OF

DISTRIBUTION TRENCHES

PLACE SYNTHETIC

DRAINAGE FABRIC OVER

DISTRIBUTION TRENCHES

SECTION A-A (TYPICAL SECTION)

NOTES:

GRAVEL IN DISTRIBUTION TRENCHES SHALL BE PLACED A MINIMUM OF 6 INCHES

BELOW THE DISTRIBUTION PIPE, AND A MINIMUM OF 2 INCHES ABOVE THE

DISTRIBUTION PIPE.

MATERIAL UTILIZED IN DISTRIBUTION TRENCHES SHALL COMPLY WITH SPECS AS

OUTLINED IN SHEET 3 OF THESE PLANS AND CHAPTER 69 OF IOWA CODE.

FILL SAND UTILIZED SHALL COMPLY WITH MATERIAL SPECS FOUND ON SHEET 3 OF

THESE PLANS, AND CHAPTER 69 OF IOWA CODE.

AREA OF MOUND SYSTEM SHALL BE STRIPPED OF VEGETATION BEFORE

CONSTRUCTION WITH THE TOP LAYER BEING PLOWED TO A DEPTH OF 8 INCHES.

TOP SOIL UTILIZED SHALL CONSIST OF QUALITY NATIVE SOIL FROM THE AREA

HAULED IN BY CONTRACTOR

CLEANOUTS ON ENDS OF DISTRIBUTION RUNS SHALL BE INSTALLED FLUSH WITH THE

GROUND SURFACE TO PROVIDE MINIMAL DISTURBANCE TO THE GOLF COURSE.

CAPS SHALL HAVE A THREADED CAP WITH GREEN LID SUITABLE FOR GOLF COURSE

MOWING OPERATIONS TO PROVIDE MINIMAL DISTURBANCE TO NORMAL

OPERATIONS.

A

A

7 DISTRIBUTION TRENCHES,

2 FOOT WIDE BY 75 FEET

LONG SPACED AT 4'-0"

MAINTAIN MINIMUM 3' OF

SEPARATION BETWEEN EDGE OF

TRENCHES AND EDGE OF

MOUND SYSTEM

ANGLE END OF DISTRIBUTION PIPE

UPWARDS, AND PLACE CLEANOUTS FLUSH

WITH NEW GROUND SURFACE (TYP.)

2" DIA. CENTERAL

FORCE MAIN

MOUND DISTRIBUTION SYSTEM PLAN VIEW

ANGLE END OF DISTRIBUTION

PIPE UPWARDS, AND PLACE

CLEANOUTS FLUSH WITH NEW

GROUND SURFACE (TYP.)

MINIMUM 36 INCH SEPARATION

BETWEEN BOTTOM OF GRAVEL AND

RESTRICTIVE LAYER

IRRIGATION LINE

7 DISTRIBUTION TRENCHES, 2

FOOT WIDE BY 75 FEET LONG

SPACED AT 4'-0"

1
2
3
4
5
6

File details come from the government source that posted it. Updated .