2412 Addendum 1.pdf
PDF 2 MB Posted
- Solicitation number
- 2412
- Issued by
- Kenosha County, Wisconsin
About this file
This Addendum No. 1, dated April 17, 2024, modifies the Kenosha County Courthouse Railing Base Restoration project bid specifications and drawings for Kenosha County, Wisconsin. The project involves the restoration of metal railings at the Kenosha County Courthouse campus located at 912 56th Street, Kenosha, WI 53140. The addendum revises multiple drawing sheets (A102, A103, A104, A105, A106, and A107) to include detailed modifications for enlarged entry elevations, stair sections, and repair details at both the main courthouse and Molinaro Building locations. Key modifications include new notes on entry elevations requiring temporary railing assemblies during restoration work, notification requirements if base plate material section loss exceeds 50 percent, and detailed repair specifications for embedded railing posts using new 1-1/2" x 0.065" HSS stainless steel 316 square tube posts with square V butt welded connections. The addendum also adds three new detail drawings (Details 5, 6, and 7 on Sheet A104) and renames existing details to clarify repair procedures and painting phasing requirements.
The addendum updates specification sections related to execution and closeout requirements, pipe and tube railings, and high-performance coatings, including modifications to reference standards, submittal requirements, manufacturers, aluminum materials and finishes, coating preparation, cleaning, and protection procedures. Bidders must submit bids using the revised Bid Offer Form attached to the addendum, which includes pricing for a base bid covering all labor and materials, plus three alternate bids: Alternate 1 for wire brush and paint of entire rails on-site, Alternate 2 for media blast and paint of entire rails off-site, and Alternate 3 for complete railing replacement. Bidders must also specify lead time to begin work and days required to complete work after notice to proceed, and include a required bid bond with their submission.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
April 17, 2024
Courthouse Railing Base Restoration Kenosha County Courthouse Kenosha County 912 56th Street, Kenosha, WI 53140
ADDENDUM NO.1
Drawings:
1) Sheet A102
a. Detail 1, Enlarged North Entry Elevation has been modified to include two (2) new notes.
b. Detail 2, Enlarged East Entry Elevation has been modified to include two (2) new notes.
c. Detail 5, East Entry Center Stair Elevation (West Elevation Similar) has been modified to include three (3) new notes.
2) Sheet A103
a. Detail 1, Enlarged South Entry Elevation – Molinaro Building has been modified to include two (2) new notes.
b. Detail 2, South Entry Stair East Elevation – Molinaro Building (West
Elevation Similar) has been modified to include two (2) new notes.
c. Detail 3, Enlarged North Entry Elevation – Molinaro Building has been modified to include two (2) new notes.
3) Sheet A104
a. Detail 2 has been renamed to “Post Repair Detail”.
b. Detail 3 has been renamed to “Enlarged Repair Detail”.
c. Detail 4 has been renamed to “Enlarged Post Repair Embedment
Detail”.
d. Detail 5 has been added to the Drawings.
e. Detail 6 has been added to the Drawings.
f. Detail 7 has been added to the Drawings.
4) Sheet A105
a. Section 017000, Execution and Closeout Requirements, Part 3 Execution, 3.05 Alterations has been modified to include item(s):
i. B.3
ii. B.4
5) Sheet A106
a. Section 055213, Pipe and Tube Railings, Part 1 General, has been modified to include item(s):
i. 1.02 Related Requirements
ii. 1.02.A
6) Sheet A107
a. Section 055213, Pipe and Tube Railings, Part 1 General, 1.03
Reference Standards, has been modified to include item(s):
i. 1.03.E
ii. 1.03.F
iii. 1.03.G
iv. 1.03.H
v. 1.03.I
vi. 1.03.J
b. Section 055213, Pipe and Tube Railings, Part 1 General, has been modified to include item(s):
i. 1.04 Submittals
c. Section 055213, Pipe and Tube Railings, Part 2 Products, has been modified to included item(s):
i. 2.01 Manufacturers
d. Section 055213, Pipe and Tube Railings, Part 2 Products, 2.02 Railings – General Requirements, has been modified to included item(s):
i. 2.02. B
ii. 2.02. C
iii. 2.02. E.2
iv. 2.02. E.3
v. 2.02. E.4
e. Section 055213, Pipe and Tube Railings, Part 2 Products, has been modified to included item(s):
i. 2.03 Aluminum Materials
f. Section 055213, Pipe and Tube Railings, Part 2 Products, has been modified to included item(s):
i. 2.06 Aluminum Finishes (Alternate #3)
g. Section 099600, High-Performance Coatings, Part 3 Execution, 3.02 Preparation has been modified to included item(s):
i. 3.02. C.1
ii. 3.02. C.2
iii. 3.02. C.2.a
h. Section 099600, High-Performance Coatings, Part 3 Execution, has been modified to included item(s):
i. 3.07 Cleaning
ii. 3.08 Protection
Please find the revised Sheets A102, A103, A104, A105, A106, and A107 with an Addendum #1 date of 4/17/24 attached.
When submitting a Bid, Contractor shall use the “Revised Bid Offer Form” which is attached to this addendum.
END OF ADDENDUM NO. 1
8' - 2 247/256"
5' - 9 29/64"
3' - 7 1/2"
11' - 8 67/128"
/1
/2
12' - 6 33/64"
Number
Sheet
Scale
Number
Type
Issued
DFD
Set
Date
Graphic
Revisions:
InSite Consulting Architects 744 Williamson St. /STE 101
Madison, Wisconsin 53703
1.800.453.8086 info@icsarc.com
As indicated
C O
U R
T H
O U
S E
R A
IL
IN
G B
A S
E R
E S
T O
R A
T
IO
N K
E N
O S
H A
C O
U N
T Y
C O
U R
T H
O U
S E
K E
N O
S H
A C
O U
N T
Y
T H
S T
R E
E T
K
E N
O S
H A
W
I
A102
KC NO. 2412
BID SET
03/25/2024
E N
L A
R G
E D
C O
U R
T H
O U
S E
R A
IL
IN
G E
L E
V A
T O
N S
A N
D S
E C
T
IO
N S
SCALE: 1/2" = 1'-0"A102
1 ENLARGED NORTH ENTRY ELEVATION
SCALE: 3/4" = 1'-0"A102
2 NORTH ENTRY STAIR SECTION
SCALE: 1/2" = 1'-0"A102
3 ENLARGED EAST ENTRY ELEVATION
SCALE: 3/4" = 1'-0"A102
EAST ENTRY - NORTH STAIR SECTION
(SOUTH STAIR SIMILAR)
SCALE: 3/4" = 1'-0"A102
EAST ENTRY CENTER STAIR ELEVATION
(WEST ELEVATION SIMILAR)
1 4.17.24 ADD NO.1
SEE DETAIL 2/A102
SEE DETAIL 4/A102
SEE DETAIL 5/A102
UPON REMOVAL OF METAL RAILING ASSEMBLY,
PROVIDE TEMPORARY RAILING ASSEMBLEY UNTIL
INSTALLATION OF REPAIRED RAILING ASSEMBLY.
UPON REMOVAL OF METAL RAILING
ASSEMBLY, PROVIDE TEMPORARY
RAILING ASSEMBLEY UNTIL
INSTALLATION OF REPAIRED RAILING
ASSEMBLY.
UPON REMOVAL OF METAL RAILING
ASSEMBLY, PROVIDE TEMPORARY
RAILING ASSEMBLEY UNTIL
INSTALLATION OF REPAIRED RAILING
ASSEMBLY.
UPON REMOVAL OF METAL RAILING
ASSEMBLY, PROVIDE TEMPORARY
RAILING ASSEMBLEY UNTIL
INSTALLATION OF REPAIRED RAILING
ASSEMBLY.
1 1
CLEAN, PRIME, AND PAINT BASE PLATE AND
VERTICAL LEGS. NOTIFY ARCHITECT IF MORE
THAN 50% SECTION LOSS OF BASE PLATE
MATERIAL HAS OCURRED.
CLEAN, PRIME, AND PAINT BASE PLATE AND
VERTICAL LEGS. NOTIFY ARCHITECT IF MORE
THAN 50% SECTION LOSS OF BASE PLATE
MATERIAL HAS OCURRED.
SEE DETAIL 1/A104 FOR EMBEDDED RAILING
REPAIRS.
1 1
13' - 11 1/2"
/2
9' - 2 3/64"
/2
Number
Sheet
Scale
Number
Type
Issued
DFD
Set
Date
Graphic
Revisions:
InSite Consulting Architects 744 Williamson St. /STE 101
Madison, Wisconsin 53703
1.800.453.8086 info@icsarc.com
As indicated
C O
U R
T H
O U
S E
R A
IL
IN
G B
A S
E R
E S
T O
R A
T
IO
N K
E N
O S
H A
C O
U N
T Y
C O
U R
T H
O U
S E
K E
N O
S H
A C
O U
N T
Y
T H
S T
R E
E T
K
E N
O S
H A
W
I
A103
KC NO. 2412
BID SET
03/25/2024
E N
L A
R G
E D
M O
L
IN
A R
O B
U
IL
D
IN
G R
A
IL
IN
G
E L
E V
S E
C T
IO
N
S
SCALE: 1/2" = 1'-0"A103
ENLARGED SOUTH ENTRY ELEVATION -
MOLINARO BUILDING
SCALE: 1" = 1'-0"A103
SOUTH ENTRY STAIR EAST ELEVATION -
MOLINARO BUILDING (WEST ELEVATION
SIMILAR)
SCALE: 1/2" = 1'-0"A103
ENLARGED NORTH ENTRY ELEVATION -
MOLINARO BUILDING
SCALE: 1" = 1'-0"A103
NORTH ENTRY STAIR ELEVATION -
MOLINARO BUILDING (SOUTH
ELEVATION SIMILAR)
1 4.17.24 ADD NO.1
SEE DETAIL 2/A103
SEE DETAIL 4/A103
UPON REMOVAL OF METAL RAILING ASSEMBLY,
PROVIDE TEMPORARY RAILING ASSEMBLEY UNTIL
REPAIRED RAILING ASSEMBLY IS REINSTALLED.
UPON REMOVAL OF METAL RAILING ASSEMBLY,
PROVIDE TEMPORARY RAILING ASSEMBLEY UNTIL
REPAIRED RAILING ASSEMBLY IS REINTALLED.
PROVIDE TEMPORARY ADA COMPLIANT RAILING ASSEMBLEY DURING
THE REPAIR WORK. TEMPORARILLY REMOUNT THE EXISTING
MAILBOX AND WIRELESS ADA DOOR OPERATOR PUSH PLATE TO
TEMPORARY RAILING STRUCTURE. ONCE RAILINGS ARE
REINSTALLED, REMOUNT MAILBOX AND PUSH PLATE TO ORIGINAL
METAL RAILING.
PROVIDE TEMPORARY ADA COMPLIANT
RAILING ASSEMBLEY DURING THE REPAIR
WORK.
REMOVE ADA DOOR OPERATOR PUSH PLATE. TEMPORARILLY
INSTALL AT TEMPORARY ADA RAILING ASSEMBLY. UPON
INSTALLATION OF REPAIRED METAL RAILING ASSEMBLY,
REINSTALL ADA OPERATOR AT ORIGINAL LOCATION.
REMOVE OVERNIGHT MAILBOX. TEMPORARILLY INSTALL AT
TEMPORARY ADA RAILING ASSEMBLY. UPON INSTALLATION
OF REPAIRED METAL RAILING ASSEMBLY, REINSTALL MAILBOX
AT ORIGINAL LOCATION.
A105
A105
(M
IN
(M
IN
0' - 1" 0' - 1"
M
IN
0' - 1" 0' - 1"
MIN.
0' - 3"
Number
Sheet
Scale
Number
Type
Issued
DFD
Set
Date
Graphic
Revisions:
InSite Consulting Architects 744 Williamson St. /STE 101
Madison, Wisconsin 53703
1.800.453.8086 info@icsarc.com
As indicated
C O
U R
T H
O U
S E
R A
IL
IN
G B
A S
E R
E S
T O
R A
T
IO
N K
E N
O S
H A
C O
U N
T Y
C O
U R
T H
O U
S E
K E
N O
S H
A C
O U
N T
Y
T H
S T
R E
E T
K
E N
O S
H A
W
I
A104
KC NO. 2412
BID SET
03/25/2024
R A
IL
IN
G R
E P
A
IR
A N
D P
A
IN
T P
H A
S
IN
G D
E T
A
IL
S
1 4.17.24 ADD NO.1
EXISTING CONCRETE SLAB TO REMAIN
CUT EXISTING RAILING POST TO ALLOW
FOR REMOVAL OF RAILING
DEMO EXISTING CONCRETE AT STEEL POST
EMBEDDMENT. MECHANICALLY CORE TO PROVIDE
UNIFORM MINIMUM 1" OF DEMOLITION BETWEEN POST
AND CONCRETE TO REMAIN.
PROTECT RAILING FINISH DURING DEMOLITION
ACTIVITIES
PREP AND CLEAN BOTTOM RAIL AND NEW POST
PRIOR TO WELDING
NEW STEEL POST. MATCH EXISTING LENGHT.
PREP, PRIME, AND PAINT PRIOR TO INSTALLATION
NEW SQUARE V BUTT WELDED CONNECTION
NEW CEMENTITOUS GROUT FILL
EXISTING CONCRETE
PAINT ENTIRE LENGHT OF BOTTOM RAIL AFFECTED
BY WELDING REPAIRS
NEW 1-1/2" X 0.065" HSS STAINLESS SQUARE TUBE 316 POST
SQUARE V BUTT WELD
PREP, PRIME, AND PAINT NEW STAINLESS
STEEL POST UPON COMPLETION OF
WELDING REPAIR
PREP, PRIME, AND PAINT BOTTOM STEEL
RAIL UPON COMPLETION OF WELDING
REPAIR
SCALE: 3" = 1'-0"A104
2 POST REPAIR DETAIL
SCALE: 6" = 1'-0"A104
3 ENLARGED POST REPAIR DETAIL
SCALE: 3" = 1'-0"A104
1 HANDRAIL REMOVAL DETAIL - TYP.
SCALE: 6" = 1'-0"A104
ENLARGED POST REPAIR
EMBEDDMENT DETAIL
NEW 1-1/2" X 0.065" HSS STAINLES SQUARE TUBE 316 POST
PREP, PRIME, AND PAINT NEW STEEL
POST UPON COMPLETION OF WELDING
REPAIR
NEW CEMENTITIOUS GROUT FILL. PROVIDE MINIMUM 1" DISTANCE BETWEEN
SIDE OF POST AND EXISTING CONCRETE.
EMBEDD NEW POST A MINIMUM OF 6 INCHES. SET TRUE AND PLUM TO GROUND
CONCRETE PLANE.
MAINTAIN MINIMUM 1" OF EXISTING STEEL POST.
REMOVE EXISTING METAL COATING PRIOR TO
WELDING.
SCALE: 1 1/2" = 1'-0"A104
ALTERNATE 1 - WIRE BRUSH AND PAINT
100%
SCALE: 1 1/2" = 1'-0"A104
ALTERNATE 2 - MEDIA BLAST AND
PAINT 100%
BASE BID PAINT REPAIRS
ALTERNATE #1 PAINT
REPAIRS
ALTERNATE #2 PAINT
REPAIRS
EXTENT OF BASE PAINT
REPAIRS AT NEW
EMBEDDED POST AND
HORIZTONAL BOTTOM RAIL
MEMBERS.
ALTERNATE #1 PAINT
REPAIRS TO BE PERFORMED
IN ADDITION TO BASE BID
PAINT REPAIRS.
ALTERNATE #2 -
PAINT REPAIRS TO BE
PERFORMED IN LIEU OF
BASE BID PAINT REPAIRS
SCALE: 1 1/2" = 1'-0"A104
ALTERNATE 3 - REPLACE RAILING WITH
NEW
ALTERNATE #3 -
PROVIDE NEW ADA
COMPLIANT RAILING AT
RAILING LOCATIONS
INDICATED ON
DRAWINGS TO RECEIVE
BASE BID REPAIRS.
Number
Sheet
Scale
Number
Type
Issued
DFD
Set
Date
Graphic
Revisions:
InSite Consulting Architects 744 Williamson St. /STE 101
Madison, Wisconsin 53703
1.800.453.8086 info@icsarc.com
C O
U R
T H
O U
S E
R A
IL
IN
G B
A S
E R
E S
T O
R A
T
IO
N K
E N
O S
H A
C O
U N
T Y
C O
U R
T H
O U
S E
K E
N O
S H
A C
O U
N T
Y
T H
S T
R E
E T
K
E N
O S
H A
W
I
A105
KC NO. 2412
BID SET
03/25/2024
G U
ID
E
L
IN
E S
P E
C
IF
IC
A
T
IO
N
1 4.17.24 ADD NO.1
Scale
Number
Type
Issued
DFD
Set
Date
Graphic
Revisions:
InSite Consulting Architects 744 Williamson St. /STE 101
Madison, Wisconsin 53703
1.800.453.8086 info@icsarc.com
C O
U R
T H
O U
S E
R A
IL
IN
G B
A S
E R
E S
T O
R A
T
IO
N K
E N
O S
H A
C O
U N
T Y
C O
U R
T H
O U
S E
K E
N O
S H
A C
O U
N T
Y
T H
S T
R E
E T
K
E N
O S
H A
W
I
A106
KC NO. 2412
BID SET
03/25/2024
G U
ID
E
L
IN
E S
P E
C
IF
IC
A
T
IO
N
1 4.17.24 ADD NO.1
Scale
Number
Type
Issued
DFD
Set
Date
Graphic
Revisions:
InSite Consulting Architects 744 Williamson St. /STE 101
Madison, Wisconsin 53703
1.800.453.8086 info@icsarc.com
C O
U R
T H
O U
S E
R A
IL
IN
G B
A S
E R
E S
T O
R A
T
IO
N K
E N
O S
H A
C O
U N
T Y
C O
U R
T H
O U
S E
K E
N O
S H
A C
O U
N T
Y
T H
S T
R E
E T
K
E N
O S
H A
W
I
A107
KC NO. 2412
BID SET
03/25/2024
G U
ID
E
L
IN
E S
P E
C
IF
IC
A
T
IO
N
1 4.17.24 ADD NO.1
KENOSHA COUNTY BID #2412
WISCONSIN PAGE 1 OF 1
ATTACHMENT C
REVISED BID OFFER FORM
Vendor:____________________________________________________________________________
BASE BID
Base Bid: Provide all labor and materials to complete all work per bid terms, conditions, and specifications
ALTERNATE BIDS:
The base bid includes painting the new base and bottom rail per bid specifications. The following are alternates to the base bid:
Alternate 1 – Wire brush and paint the entire rail a uniform color per paint specifications. This work may be done on site. Amount added to base bid
Alternate 2 – Media blast and paint the entire rail a uniform color off site per paint specifications. Amount added to base bid.
Alternate 3 – Replace the entire railings per bid specifications and specifications included in Addendum 1. Amount added to base bid.
Lead time to begin work is __________ days after notice to proceed
Lead time to complete work is __________ days after work begins
Bid Bond (Required) is included? Yes_____ No______
Kenosha County is exempt from Federal Excise and Wisconsin Sales Taxes, 77.54(9a)(b) WI Stats.
Kenosha County’s CES number is 008-1020421892-06.
File details come from the government source that posted it. Updated .