241127 - STANTONSBURG - COMPLETE PRICING.pdf
PDF 15 MB Posted
- Attached to
- Stantonsburg Town Hall Municipal Complex Project
- Solicitation number
- 102812312024
- Issued by
- Watauga County, Wade Town, North Carolina
About this file
This is a complete set of architectural, mechanical, electrical and plumbing drawings for renovations to the Stantonsburg Town Hall & Police Department building located at 312 S. Main Street in Stantonsburg, NC. The project (#24-019) is being managed by Turpentine Design and is marked "FOR PRICING PURPOSES ONLY, NOT FOR CONSTRUCTION" with a date of 11.27.2024. The drawings detail extensive interior renovations including modifications to the council room, offices, public spaces, restrooms, and support areas. The plans include demolition and new construction drawings for architectural elements, mechanical systems, electrical systems, plumbing fixtures, fire alarm systems, and related infrastructure modifications.
The drawing set contains detailed specifications for materials, finishes, fixtures and equipment to be used throughout the renovation. This includes lighting fixtures, plumbing fixtures, HVAC modifications, electrical panel upgrades, fire alarm components, and architectural finishes like flooring, wall coverings, and millwork. The plans emphasize maintaining operations during construction and proper coordination between trades. While marked for pricing purposes, no specific budget information is included in the drawings. The plans appear to be at approximately 90% completion level based on the revision dates shown.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CS1.0
STANTONSBURG
TOWN HALL & POLICE DEPARTMENT
E0.1
COVER SHEET
ARCHITECTURAL
MECHANICAL
ELECTRICAL
CS1.0
MECHANICAL COVER SHEET M0.1
FLOOR PLAN - DEMOLITION POWER
DRAWING SUMMARY
11.27.2024PRICING
PROJECT #: 24-019
FOR PRICING PURPOSES ONLY,
NOT CONSTRUCTION
312 S. MAIN STREET
STANTONSBURG, NC 27833
1007 Procure Street Fuquay-Varina, NC 27526
919.412.9138
CODE SUMMARYCS2.0
LIFE SAFETY PLAN CS2.1
SPECIFICATIONS CS3.0
SPECIFICATIONS CS3.1
SYMBOLS LEGENDSCS4.0
TYPICAL ANSI DETAILS CS6.0
TYPICAL ANSI DETAILS CS6.1
DEMOLITION FLOOR PLANAD1.1
CONSTRUCTION FLOOR PLAN A1.1
DEMO REFLECTED CEILING PLAN AD2.1
NEW REFLECTED CEILING PLAN A2.1
FINISH PLAN A3.0
FURNITURE AND EQUIPMENT PLAN A4.1
ROOF PLAN A5.0
ENLARGED PLANS AND ELEVATIONSA8.0
ENLARGED PLANS AND ELEVATIONSA8.1
ENLARGED PLANS AND ELEVATIONSA8.2
MILLWORK DETAILS A11.0
MILLWORK DETAILSA11.1
MILLWORK DETAILSA11.2
DOOR SCHEDULE AND DETAILS A12.0
P1.1
PLUMBING
FLOOR PLAN - DEMOLITION PLUMBING
MECHANICAL SCHEDULES M0.2
CRAWLSPACE PLAN - MECHANICAL DEMOLITION M1.1
ATTIC PLAN - MECHANICAL DEMOLITION M1.2
CRAWLSPACE PLAN - MECHANICAL M2.1
ATTIC PLAN - MECHANICAL M2.2
MECHANICAL DETAILS M3.1
E0.2 FLOOR PLAN - POWER
E1.1 FLOOR PLAN - DEMOLITION POWER
E1.2 FLOOR PLAN - POWER
E1.3 FLOOR PLAN - MECHANICAL CONNECTIONS
E2.1 FLOOR PLAN - DEMOLITION LIGHTING
E2.2 FLOOR PLAN - LIGHTING
E3.1 ELECTRICAL DETAILS
E3.2 ELECTRICAL DETAILS
FA1.1 FLOOR PLAN - FIRE ALARM
FA2.1 FIRE ALARM DETAILS
FA2.2 FIRE ALARM DETAILS
P1.2 FLOOR PLAN - WASTE & VENT
P1.3 FLOOR PLAN - WATER
P2.1 PLUMBING RISER
P2.2 PLUMBING RISER
2018 APPENDIX B
BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS
(EXCEPT 1 AND 2 - FAMILY DWELLINGS AND TOWNHOUSES)
A. PROJECT INFORMATION
NAME OF PROJECT: STANTONSBURG TOWN HALL & POLICE DEPARTMENT
ADDRESS: 312 S. MAIN STREET ZIP CODE: 27833
OWNER/AUTHORIZED AGENT: BRIAN HAWLEY PHONE: 252.238.3608 EMAIL: BHAWLEY@TOWNOFSTANTONSBURG.COM
OWNED BY: CITY COUNTY STATE PRIVATE
CODE ENFORCEMENT JURISDICTION: CITY COUNTY STATE
C. CODE DATA
2018 NC BUILDING CODE: (SELECT ONE):
NEW BUILDING ADDITION RENOVATION FIRST TIME INTERIOR COMPLETION
SHELL/CORE - CONTACT THE LOCAL INSPECTION JURISDICTION FOR POSSIBLE ADDITIONAL PR0CEDURES AND
REQUIREMENTS
PHASED CONSTRUCTION - SHELL/CORE- CONTACT THE LOCAL INSPECTION JURISDICTION OR POSSIBLE ADDITIONAL
PR0DECURES AND REQUIREMENTS
2018 NC EXISTING BUILDING CODE: (SELECT ONE): PRESCRIPTIVE REPAIR CHAPTER 14
ALTERATION: LEVEL I LEVEL II LEVEL III
HISTORIC PROPERTY CHANGE OF USE
CONSTRUCTED (DATE): 1979 CURRENT OCCUPANCY(S) (CH. 3): B
RENOVATED (DATE): N/A PROPOSED OCCUPANCY (S) (CH.3): B & A-3
RISK CATEGORY (TABLE 1604.5) CURRENT N/A I II III IV
PROPOSED N/A I II III IV
D. BASIC BUILDING DATA
CONSTRUCTION TYPE: I-A I-B II-A II-B II-B III-A III-B IV
V-A V-B
SPRINKLERS: YES NO PARTIAL NFPA 13 NFPA 13R NFPA 13D
STANDPIPES: NO YES CLASS I II WET DRY
FIRE DISTRICT: YES NO FLOOD HAZARD AREA YES NO
SPECIAL INSPECTIONS REQUIRED: NO YES (CONTACT THE LOCAL INSPECTION JURISDICTION FOR ADDITIONAL
PROCEDURES AND REQUIREMENTS).
GROSS BUILDING AREA TABLE
FLOOR EXISTING (S.F.) REN. AREA (S.F.) NEW (S.F.) SUB-TOTAL
1ST FLOOR 5,380 5,380 0 5,380
TOTALS 5,380 5,380 0 5,380
F. ALLOWABLE HEIGHT
BUILDING HEIGHT IN FEET (TABLE 504.3) 40' EXISTING
BUILDING HEIGHT IN STORIES (TABLE 504.4) 1 1
ALLOWABLE SHOWN ON PLANS CODE REFERENCE
G. FIRE PROTECTION REQUIREMENTS
BUILDING ELEMENT FIRE
SEPARATION
DISTANCE
(FEET)
RATING DETAIL #
AND
SHEET #
DESIGN #
FOR RATED
ASSEMBLY
REQ'D. PROVIDED
(W/ XXX*
REDUCTION)
SHEET #
FOR RATED
PENETRATION
SHEET #
FOR RATED
JOINTS
H. PERCENTAGE OF WALL OPENINGS
FIRE SEPARATION DISTANCE (FEET)
FROM PROPERTY LINE
DEGREE OF OPENINGS PROTECTION
(TABLE 705.8) ALLOWABLE AREA (%) ACTUAL SHOWN ON
PLANS (%)
30 OR GREATER UP, NS NO LIMIT N/A
* INDICATE SECTION NUMBER PERMITTING REDUCTION
STRUCTURAL FRAME, INCLUDING
COLUMNS, GIRDERS, & TRUSSES
BEARING WALLS
EXTERIOR
NORTH
SOUTH
EAST
WEST
INTERIOR
NONBEARING WALLS & PARTITIONS
EXTERIOR WALLS
NORTH
SOUTH
EAST
WEST
INTERIOR WALLS & PARTITIONS
FLOOR CONSTRUCTION INCLUDING
SUPPORTING BEAMS & JOISTS
FLOOR CEILING ASSEMBLY
COLUMNS SUPPORTING FLOORS
ROOF CONSTRUCTION INCLUDING
SUPPORTING BEAMS & JOISTS
ROOF CEILING ASSEMBLY
COLUMNS SUPPORTING ROOF
SHAFT ENCLOSURES - EXIT
SHAFT ENCLOSURES - OTHER
CORRIDOR SEPARATION
OCCUPANCY/FIRE BARRIER
SEPARATION 2-HOUR 2-HOUR U301
PARTY/FIRE WALL SEPARATION
SMOKE BARRIER SEPARATION
SMOKE PARTITION
TENANT/DWELLING UNIT/ SLEEPING
UNIT SEPARATION
INCIDENTAL USE SEPARATION
L. ACCESSIBLE PARKING (SECTION 1106)
TOTAL
LOT OR PARKING
AREA
TOTAL # OF PARKING SPACES
REQUIRED PROVIDED
# OF ACCESSIBLE SPACES PROVIDED
96" SPACES 132" SPACES
N. SPECIAL APPROVALS
SPECIAL APPROVAL: (LOCAL JURISDICTION, DEPARTMENT OF INSURANCE, OSC, DPI, DHHS, ETC.)
N/A
Q. MECHANICAL DESIGN (PROVIDE ON THE MECHANICAL SHEETS IF APPLICABLE)
MECHANICAL SYSTEMS, SERVICE SYSTEMS & EQUIPMENT
THERMAL ZONE:
WINTER DRY BULB: XXX
SUMMER DRY BULB: XXX
INTERIOR DESIGN CONDITIONS: XXX
WINTER DRY BULB: XXX
SUMMER DRY BULB: XXX
RELATIVE HUMIDITY: XXX
BUILDING HEATING LOAD: XXX
BUILDING COOLING LOAD: XXX
MECHANICAL SPACING CONDITIONING SYSTEM:
UNITARY
DESCRIPTION OF UNIT: XXX
HEATING EFFICIENCY: XXX
COOLING EFFICIENCY: XXX
SIZE CATEGORY OF UNIT: XXX
BOILER:
SIZE CATEGORY. IF OVERSIZED, STATE REASON: XXX
CHILLER:
SIZE CATEGORY. IF OVERSIZED, STATE REASON: XXX
LIST EQUIPMENT EFFICIENCIES: XXX
R. ELECTRICAL DESIGN
(PROVIDE ON THE ELECTRICAL SHEETS IF APPLICABLE)
ELECTRICAL SUMMARY
ELECTRICAL SYSTEM & EQUIPMENT
METHOD OF COMPLIANCE: ENERGY CODE PRESCRIPTIVE PERFORMANCE
ASHRAE 90.1 PRESCRIPTIVE PERFORMANCE
LIGHTING SCHEDULE (EACH FIXTURE TYPE)
LAMP TYPE REQUIRED IN FIXTURE
NUMBER OF LAMPS IN FIXTURE
BALLAST TYPE USED IN FIXTURE
NUMBER OF BALLASTS IN FIXTURE
TOTAL WATTAGE PER FIXTURE
TOTAL INTERIOR WATTAGE SPECIFIED VS. ALLOWED (WHOLE BUILDING
OR SPACE BY SPACE)
TOTAL EXTERIOR WATTAGE SPECIFIED VS. ALLOWED
ADDITIONAL EFFICIENCY PACKAGE OPTIONS
(WHEN USING THE 2018 NCECC; NOT REQUIRED FOR ASHRAE 90.1)
C406.2 MORE EFFICIENT HVAC EQUIPMENT PERFORMANCE
C406.3 REDUCED LIGHTING POWER DENSITY
C406.4 ENHANCED DIGITAL LIGHTING CONTROLS
C406.5 ON-SITE RENEWABLE ENERGY
C406.6 DEDICATED OUTDOOR AIR SYSTEM
C406.7 REDUCED ENERGY USE IN SERVICE WATER HEATER
B. DESIGN PROFESSIONAL INFORMATION
CONTACT: JESSICA SWANSON
DESIGNER FIRM NAME LICENSE PHONE EMAIL
ARCHITECTURAL TURPENTINE DESIGN JESSICA SWANSON 15382 919.412.9138 JESS@TURPENTINE-DESIGN.COM
CIVIL - - -
ELECTRICAL ALIGN ENGINEERING RICHARD COPELAND NC 29517 919.650.6565 RICK@AE-NC.COM
FIRE ALARM ALIGN ENGINEERING RICHARD COPELAND NC 29517 919.650.6565 RICK@AE-NC.COM
PLUMBING ALIGN ENGINEERING EMMETT WILLIS NC 041129 919.650.6565 EMMETT@AE-NC.COM
MECHANICAL ALIGN ENGINEERING NATHAN ROMBLAD NC 041129 919.650.6565 NATHAN@AE-NC.COM
SPRINKLER-STANDPIPE - - - - -
STRUCTURAL - - - - -
RETAINING WALLS <5' HIGH - - - - -
OTHER - - - - -
E. ALLOWABLE AREA
PRIMARY OCCUPANCY CLASSIFICATION(S):
ASSEMBLY A-1 ASSEMBLY A-2 ASSEMBLY A-3
ASSEMBLY A-4 ASSEMBLY A-5 BUSINESS
EDUCATIONAL FACTORY F-1 FACTORY F-2
HAZARDOUS-1 DETONATE HAZARDOUS H-2 DEFLAGRATE HAZARDOUS-3 COMBUST
HAZARDOUS H-4 HEALTH HAZARDOUS H-5 HPM INSTITUTIONAL I-1 CONDITION 1
INSTITUTIONAL I-1 CONDITION 2 INSTITUTIONAL I-2-CONDITION 1 INSTITUTIONAL I-2 CONDITION 2
INSTITUTIONAL I-3 CONDITION 1 INSTITUTIONAL I-3 CONDITION 2 INSTITUTIONAL I-3 CONDITION 3
INSTITUTIONAL I-3 CONDITION 4 INSTITUTIONAL I-3 CONDITION 5 INSTITUTIONAL I-4
MERCANTILE RESIDENTIAL R-1 RESIDENTIAL R-2
RESIDENTIAL R-3 RESIDENTIAL R-4 STORAGE S-1
STORAGE S-1 HIGH PILE STORAGE S-2 STORAGE S-2 HIGH-PILED
STORAGE PKNG. GARAGE (OPEN) STORAGE PARKING GARAGE (ENCLOSED) STORAGE REPAIR GARAGE
UTILITY AND MISC.
ACCESSORY OCCUPANCY CLASSIFICATIONS(S): N/A
INCIDENTAL USES (TABLE 509): N/A
SPECIAL USES (CHAPTER 4 - LIST CODE SECTIONS): N/A
SPECIAL PROVISIONS: (CHAPTER 5 - LIST CODE SECTIONS): N/A
MIXED OCCUPANCY: YES NO SEPARATION: 2 HR. EXCEPTION: XXX
SELECT ONE:
NON-SEPARATED USE (508.3)
SEPARATED USE (508.4) - SEE BELOW FOR AREA CALCULATIONS FOR EACH STORY, THE AREA OF THE
OCCUPANCY SHALL BE SUCH THAT THE SUM OF THE RATIOS OF THE ACTUAL FLOOR AREA OF EACH USE
DIVIDED BY THE ALLOWABLE FLOOR AREA FOR EACH USE SHALL NOT EXCEED 1.
ACTUAL AREA OF OCC. A + ACTUAL AREA OF OCC. B ≤1
ALLOWABLE AREA OF OCC. A ALLOWABLE AREA OF OCC. B
+ + ... ... = ≤1.0
STORY NO. DESCRIPTION
AND USE
(A)
BLDG. AREA PER STORY
(ACTUAL)
(B)
TABLE 506.2 (4)
AREA
(C)
AREA FOR
FRONTAGE
INCREASE (1,5)
(D)
ALLOWABLE AREA
PER STORY OR
UNLIMTED (2,3)
1. FRONTAGE INCREASES FROM SECTION 506.3 ARE COMPUTED THUS:
A. PERIMETER WHICH FRONTS A PUBLIC WAY OR OPEN SPACE HAVING 20 FT. MIN. WIDTH = XXXX (F)
B. TOTAL BUILDING PERIMETER = XXX (P)
C. RATIO (F/P) = XXX (F/P)
D. W = MINIMUM WIDTH OF PUBLIC WAY = XXX (W)
E. PERCENT OF FRONTAGE INCREASE I(F) = 100{(F/P - 0.25} X W/30 = XXX (%)
2. UNLIMITED AREA APPLICABLE UNDER CONDITIONS OF SECTION 507.
3. MAXIMUM BUILDING AREA = TOTAL NUMBER OF STORIES IN THE BUILDING X D (MAXIMUM 3 STORIES) (506.2).
4. THE MAXIMUM AREA OF OPEN PARKING GARAGES MUST COMPLY WITH TABLE 406.5.4.
5. FRONTAGE INCREASE IS BASED ON THE UNSPRINKLERD AREA VALUE IN TABLE 506.2
1. PROVIDE CODE REFERENCE IF THE "SHOWN ON PLANS" QUANITY IS NOT BASED ON TABLE 504.3 OR 504.4.
2. THE MAXIMUM HEIGHT OF AIR TRAFFIC CONTROL TOWERS MUST COMPLY WITH TABLE 412.3.1.
3. THE MAXIMUM HEIGHT OF OPEN PARKING GARAGES MUST COMPLY WITH TABLE 406.5.4.
I. LIFE SAFETY SYSTEM REQUIREMENTS
EMERGENCY LIGHTING: YES NO
EXIT SIGNS: YES NO
FIRE ALARM: YES NO
SMOKE DETECTION SYSTEMS: YES NO PARTIAL
CARBON MONOXIDE DETECTION: YES NO
K. ACCESSIBLE DWELLING UNITS (SECTION 1107)
UNIT
CLASSIFICATION
TOTAL
UNITS
ACCESSIBLE
UNITS
REQUIRED
ACCESSIBLE
UNITS
PROVIDED
TYPE A UNITS
REQUIRED
TYPE A UNITS
PROVIDED
TYPE B UNITS
REQUIRED
TYPE B UNITS
PROVIDED
TOTAL
ACCESSIBL
E UNITS
PROVIDED
TOTAL #
ACCESSIBLE
PROVIDED
NEW 1 2 2 1 1 1 2 - 1 1
REQ'D 1 1 2 - 1 1 2 - 2* 2*
USE WATERCLOSETS
MALE FEMALE
URINALS LAVATORIES
MALE FEMALE
SHOWERS/
TUBS
DRINKING FOUNTAINS
REGULAR ACCESSIBLE
M. PLUMBING FIXTURE REQUIREMENTS (TABLE 2902.1)
UNISEX UNISEX
SPACE
O. ENERGY SUMMARY
ENERGY REQUIREMENTS:
THE FOLLOWING DATA SHALL BE CONSIDERED MINIMUM AND ANY SPECIAL ATTRIBUTE REQUIRED TO MEET THE ENERGY CODE SHALL ALSO BE PROVIDED. EACH DESIGNER SHALL FURNISH THE REQUIRED PORTIONS OF THE PROJECT INFORMATION FOR THE PLAN DATA SHEET. IF PERFORMANCE METHOD, STATE THE ANNUAL ENERGY COST FOR THE STANDARD REFERENCE DESIGN VS ANNUAL ENERGY
COST FOR THE PROPOSED DESIGN.
EXISTING BUILDING ENVELOPE COMPLIES WITH CODE YES (THE REMAINDER OF THIS SECTION IS
NOT APPLICABLE)
NO
EXEMPT BUILDING NO YES (PROVIDE CODE OF STATUTORY REFERENCE): XXX
CLIMATE ZONE N/A 3A 4A 5A
METHOD OF COMPLIANCE): ENERGY CODE PERFORMANCE PRESCRIPTIVE
ASHRAE 90.1 PERFORMANCE PRESCRIPTIVE
(IF OTHER SPECIFY SOURCE HERE) XXX
THERMAL ENVELOPE (PRESCRIPTIVE METHOD ONLY)
ROOF/CEILING ASSEMBLY (EACH ASSEMBLY)
DESCRIPTION OF ASSEMBLY: XXX
U - VALUE OF TOTAL ASSEMBLY: XXX
R- VALUE OF INSULATION: XXX
SKYLIGHTS IN EACH ASSEMBLY: XXX
U- VALUE OF SKYLIGHT: XXX
TOTAL SQUARE FOOTAGE OF SKYLIGHTS IN EACH ASSEMBLY: XXX
EXTERIOR WALLS (EACH ASSEMBLY)
DESCRIPTION OF ASSEMBLY: XXX
U-VALUE OF TOTAL ASSEMBLY: XXX
R- VALUE OF INSULATION: XXX
OPENINGS (WINDOWS OR DOORS WITH GLAZING)
U-VALUE OF ASSEMBLY: XXX
SOLAR HEAT GAIN COEFFICIENT: XXX
PROJECTION FACTOR: XXX
DOOR R- VALUE: XXX
WALLS BELOW GRADE (EACH ASSEMBLY)
DESCRIPTION OF ASSEMBLY: XXX
U-VALUE OF TOTAL ASSEMBLY: XXX
R- VALUE OF INSULATION: XXX
FLOORS OVER UNCONDITIONED SPACE (EACH ASSEMBLY)
DESCRIPTION OF ASSEMBLY: XXX
U- VALUE OF TOTAL ASSEMBLY: XXX
R- VALUE OF INSULATION: XXX
FLOORS SLAB ON GRADE
DESCRIPTION OF ASSEMBLY: XXX
U- VALUE OF TOTAL ASSEMBLY: XXX
R- VALUE OF INSULATION: XXX
HORIZONTAL/VERTICAL REQUIREMENT: XXX
SLAB HEATED: XXX
P. STRUCTURAL DESIGN (PROVIDE ON STRUCTURAL SHEETS IF APPLICABLE)
DESIGN LOADS:
IMPORTANCE FACTORS SNOW (IS) XXX
SEISMIC (IE) XXX
LIVE LOADS:
ROOF XXX PSF
MEZZANINE XXX PSF
FLOOR XXX PSF
GROUND SNOW LOAD XXX PSF
WIND LOAD ULTIMATE WIND SPEED XXX MPH (ASCE-7)
EXPOSURE CATEGORY XXX
SEISMIC DESIGN CATEGORY: A B C D
PROVIDE THE FOLLOWING SEISMIC DESIGN PARAMETERS:
RISK CATEGORY (TABLE 1604.5) I II III IV
SPECTRAL RESPONSE ACCELERATION: S(S) XXX %G S(I) XXX %G
SITE CLASSIFICATION (ASCE 7): A B C D E F
DATA SOURCE: FIELD TEST PRESUMPTIVE HISTORICAL DATA
BASIC STRUCTURAL SYSTEM: BEARING WALL BUILDING FRAME MOMENT FRAME
DUAL W/ SPECIAL MOMENT FRAME
DUAL W/ INTERMEDIATE R/C OR SPECIAL STEEL
INVERTED PENDULUM
ANALYSIS PROCEDURE: SIMPLIFIED EQUIV. LATERAL FORCE DYNAMIC
ARCH./MECH. COMPONENTS ANCHORED? YES NO
LATERAL DESIGN CONTROL: EARTHQUAKE WIND
SOIL BEARING CAPACITIES:
FIELD TEST (PROVIDE COPY OF TEST REPORT) XXX PSF
PRESUMPTIVE BEARING CAPACITY XXX PSF
PILE SIZE, TYPE & CAPACITY XXX
J. LIFE SAFETY PLAN REQUIREMENTS
LIFE SAFETY PLAN SHEET #: CS2.1.
FIRE AND/OR SMOKE RATED WALL LOCATIONS (CHAPTER 7)
ASSUMED AND REAL PROPERTY LINE LOCATIONS (IF NOT ON THE SITE PLAN)
EXTERIOR WALL OPENING AREA WITH RESPECT TO DISTANCE TO ASSUMED PROPERTY LINES (705.8) OCCUPANCY USE FOR EACH AREA AS IT RELATES TO OCCUPANT LOAD CALCULATION (TABLE 1004.1.2)
OCCUPANT LOADS FOR EACH AREA
EXIT SIGN LOCATIONS (1013)
EXIT ACCESS TRAVEL DISTANCES (1017)
COMMON PATH OF TRAVEL DISTANCES (TABLES 1006.2.1 & 1006.3.2(1))
DEAD END LENGTHS (1020.4)
CLEAR EXIT WIDTHS FOR EACH EXIT DOOR
MAXIMUM CALCULATED OCCUPANT LOAD CAPACITY FOR EACH EXIT DOOR CAN ACCOMMODATE BASED ON EGRESS WIDTH (1005.3)
ACTUAL OCCUPANT LOAD FOR EACH EXIT DOOR
A SEPARATE SCHEMATIC PLAN INDICATING WHERE FIRE RATED FLOOR/CEILING AND/OR ROOF STRUCTURE PROVIDED FOR PURPOSES
OF OCCUPANCY SEPARATION
LOCATION OF DOORS WITH PANIC HARDWARE (1010.1.10)
LOCATION OF DOORS WITH DELAYED EGRESS LOCKS AND THE AMOUNT OF DELAY (1010.1.9.7)
LOCATION OF DOORS WITH ELECTROMAGNETIC EGRESS LOCKS (1010.1.9.9)
LOCATION OF DOORS EQUIPPED WITH HOLD OPEN DEVICES
LOCATION OF EMERGENCY ESCAPE WINDOWS (1030)
THE SQUARE FOOTAGE OF EACH FIRE AREA (202)
THE SQUARE FOOTAGE OF EACH SMOKE COMPARTMENT FOR OCCUPANCY CLASSIFICATIONS I-2 (407.5) NOTE ANY CODE EXCEPTIONS OR TABLE NOTES THAT MAY HAVE BEEN UTILIZED REGARDING THE ITEMS ABOVE
1 COUNCIL ROOM (A-3) 823 6,000 N/A 6,000
1 ADMIN AREAS/PD (B) 4,537 9,000 N/A 9,000
6,000
4,537 9,000
0.64
N/A
EXISTI
NG TO
RE
MAIN
N/A
EXISTI
NG TO
RE
MAIN
*PER SECTION 2902.7 AN ADJUSTMENT IN OCCUPANT CONTENT SHALL BE MADE PER OWNER REQUEST.
N/A
REF
ER
TO
MECH
ANICA
L S
HEET
S
REF
ER
TO
ELE
CTR
ICA
L S
HEET
S
CODE SUMMARY
SCALE: NTS
CS2.0
COPYRIGHT 2024 - ALL RIGHTS RESERVED
PRINTED OR ELECTRONIC DRAWINGS & DOCUMENTATION MAY NOT BE REPRODUCED OR
REDISTRIBUTED IN ANY WAY WITHOUT WRITTEN PERMISSION FROM TURPENTINE DESIGN
STANTONSBURG
TOWN HALL
312 S. MAIN ST.,
STANTONSBURG, NC 27833
SHEET #
ARCH PROJECT # 24-019
DESCRIPTION DATE
1007 Procure Street Fuquay-Varina, NC 27526
919.412.9138 turpentine-design.com
50% REVIEW 08.20.24
90% REVIEW 09.19.24
PRICING 11.27.24
FO
R
PR
IC
IN
G
PU
RP
OS
ES
O
NL
Y
NO
T
FO
R
CO
NS
TR
UC
TI
ON
LEVELSTAIR
S.F. (SECTION 1005.3)AREA EGRESS WIDTH
USE GROUPTHE PORTION OF THE MEANS OF EGRESS WHICH IS SEPARATED FROM
OTHER INTERIOR SPACES OF A BUILDING OR STRUCTURE BY
FIRE-RESISTANCE RATED CONSTRUCTION AND OPENING PROTECTIVES
AS REQUIRED TO PROVIDE A PROTECTED PATH OF EGRESS TRAVEL
BETWEEN THE EXIT ACCESS AND THE EXIT DISCHARGE. EXITS
INCLUDE EXTERIOR EXIT DOORS AT THE LEVEL OF EXIT DISCHARGE,
VERTICAL EXIT ENCLOSURES, EXIT PASSAGEWAYS, EXTERIOR EXIT
STAIRWAYS, EXTERIOR EXIT RAMPS AND HORIZONTAL EXITS.
NODE WHICH DEFINES WHERE THE COMMON PATH OF EGRESS
TRAVEL DISTANCE HAS BEEN DETERMINED. THIS POINT OCCURS
ALONG THE EXIT ACCESS ROUTE AND ESTABLISHES WHERE 2
DISTINCT PATHS OF EGRESS TRAVEL BECOME AVAILABLE.
STARTING POINT TO WHICH THE TRAVEL DISTANCE TO THE NEAREST
EXIT IS DETERMINED. THIS POINT IS DEFINED AS THE MOST REMOTE
POINT WITHIN THE SPACE OR STORY. THE TRAVEL DISTANCE IS
TAKEN ALONG THE NATURAL AND UNOBSTRUCTED PATH OF EGRESS
TRAVEL TO AN EXTERIOR EXIT DOOR AT THE LEVEL OF DISCHARGE,
AN ENTRANCE TO A VERTICAL EXIT ENCLOSURE, AN EXIT
PASSAGEWAY, A HORIZONTAL EXIT, AN EXTERIOR EXIT STAIRWAY
OR AN EXTERIOR EXIT RAMP.
LOAD (A/B)
FEC
FIRE EXTINGUISHER OR FIRE EXTINGUISHER CABINET. SEE SYMBOLS
LIBRARY FOR MORE INFORMATION ON THE SPECIFICATION.
CPT
*SUITE EXIT
*BLDG EXIT
SYMBOL INDICATING DIRECTION OF TRAVEL, OCCUPANT LOAD
SERVING DOOR, REQUIRED CLEAR WIDTH, AND PROVIDED CLEAR
WIDTH.
REQ'D. EGRESS WIDTH
ACTUAL EGRESS WIDTH
OCCUPANT LOADX
X X
FE
CALCULATED
OCCUPANCY
CLASSIFICATION
FLOOR AREA ALLOWANCE
PER OCCUPANTHATCH PATTERN
7 NET CONCENTRATED
(CHAIRS ONLY- NOT FIXED)
SHOWN ON PLANSACTUAL WIDTH
LEVELSTAIRLEVELSTAIR
EXIT WIDTH (INCHES)
OCCUPANT
REQUIRED WIDTH
(A/B) X C(TABLE 1005.3)PERAREAOR SPACE
PER OCCUPANT
(C)(B)(A)
DESCRIPTION
OCCUPANT LOAD AND EXIT WIDTH CALCULATIONS
OCCUPANT
(1004)
100 GROSS
BUSINESS (B) 100 GROSS
TOTALS
ASSEMBLY (A-3)
BUSINESS (B)
STORAGE (S-2) 300 GROSS
ASSEMBLY (A-3) (CONCENTRATED - CHAIRS
ONLY, NOT FIXED)
GC SHALL PROVIDE SIGNAGE COMPLYING WITH NCBC 1110,
E107 AND A117.1 2009.
(NO HATCH)
STORAGE (S-2)
OCCUPANCY LEGENDLIFE SAFETY GENERAL NOTESLIFE SAFETY PLAN LEGEND
7 NET
VARIES 124
300 GROSS
5,195
THIS LIFE SAFETY STUDY IS BASED ON THE 2018 NCBC.
ALL EXISTING LIFE SAFETY SYSTEMS (SPRINKLER, FIRE
ALARM, EGRESS LIGHTING AND EXIT SIGNS) SHALL BE
MAINTAINED DURING CONSTRUCTION.
GC SHALL PROVIDE (IF NOT ALREADY EXISTING) TACTILE
EXIT SIGNS AT ALL EXIT DISCHARGES PER NCBC 1011.3.
GC SHALL BE RESPONSIBLE WITH SAFEGUARDS DURING
CONSTRUCTION COMPLYING WITH NCBC CHAPTER 33.
ALL INTERIOR FINISHES SHALL COMPLY WITH NCBC T803.11.
GC TO MAINTAIN EXISTING ACCESSIBLE PARKING AS WELL
AS ACCESSIBLE ROUTE FROM ADA PARKING TO THE
BUILDING ENTRYWAY FREE AND CLEAR AT ALL TIMES
DURING AND AFTER CONSTRUCTION. IN ADDITION, ADA
ROUTE TO ACCESSIBLE RESTROOMS AND WATER
FOUNTAINS SHALL ALSO BE MAINTAINED AT ALL TIMES.
9 *NOTES:
GC SHALL MAINTAIN CLEAR PATHS OF EGRESS TO EXITS
DURING ALL PHASES OF CONSTRUCTION.
4,040 41
1 LIFE SAFETY PLAN
SCALE: 1/8" = 1'-0"
0.3 0.2 - - - -
RA
MP
DO
W N
FINANCE
OFFICER
EXISTING
UTILITY CLOSET
SGT.
OFFICE
SUPPLY
CLOSET
CHIEF
OFFICE
PUBLIC
SAFETY
EVIDENCE
TV
BILL PAY
INTERVIEW
RAMP
DOWN
RAMP
DOWN
RA
MP
DO
W N
TOWN CLERK
OFFICE
PUBLIC
RECORDS
STORAGE
PUBLIC
RECORDS
PRNT
TV I.T.
RAMP
DOWN
TV
BREAK
ROOM
TOWN
MANAGER
MAYOR
OPEN
WORK
CONFERENCE
ROOM
JAN.
BREAK
ROOM
COUNCIL
ROOM
UNISEX
UNISEX
MEN'S
WOMEN'S
A
A
LIFE SAFETY KEY NOTES
DOOR IS TO BE EQUIPPED WITH PANIC
HARDWARE. REFER TO DOOR SCHEDULE SHEET
FOR MORE INFORMATION.
X X
EXIT SIGNAGE (WALL OR CEILING MOUNTED). REFER TO ELECTRICAL
ENGINEERING DRAWINGS FOR MORE INFORMATION.
OCCUPANT LOAD POSTING - SIGNAGE THAT
MEETS NCBC 1004.3 SHALL BE PLACED IN
CONSPICUOUS PLACE NEAR MAIN EXIT. SEE
GENERAL LIFE SAFETY NOTE #1 THIS SHEET
DOOR NOTED IS EQUIPPED WITH PANIC HARDWARE. REFER TO DOOR
SCHEDULE FOR MORE INFORMATION.
"CR" SYMBOL INDICATES SECURE DOOR(S) EQUIPPED WITH
CARD READER AND ELECTRIFIED HARDWARE OR MAGNETIC
LOCK. SEE DOOR SCHEDULE FOR MORE INFORMATION.
REQUIRED DOOR SEPARATION:
(105'-11"/2) 53'-0"
ACTUAL DOOR SEPARATION: 81'-11"
OVERAL DIAGONAL: 105'-11" TRAVEL DISTANCE: 51'-0"
TRAVEL DISTANCE: 68'-5"
OVERAL DIAGONAL: 40'-9"
REQUIRED DOOR SEPARATION:
(40'-9"/2) 20'-5"
ACTUAL DOOR SEPARATION: 29'-4"
TRAVEL DISTANCE: 65'-4"
ACCESSIBLE ENTRY/EXIT
ASSEMBLY (A-3) (UNCONCENTRATED -
TABLES & CHAIRS) / PLATFORM 15 NET294 20
ASSEMBLY (A-3) 15 NET (UNCONCENTRATED TABLES
AND CHAIRS)
0.3 0.2
0.3 0.2
0.3 0.2
0.3 0.2
N/A 8.2
N/A 12.2
N/A 4
N/A 0.4
N/A 102
N/A 68
N/A 48
N/A 68
LIFE SAFETY PLAN
SCALE: 1/8" = 1'-0"
CS2.1
COPYRIGHT 2024 - ALL RIGHTS RESERVED
PRINTED OR ELECTRONIC DRAWINGS & DOCUMENTATION MAY NOT BE REPRODUCED OR
REDISTRIBUTED IN ANY WAY WITHOUT WRITTEN PERMISSION FROM TURPENTINE DESIGN
STANTONSBURG
TOWN HALL
312 S. MAIN ST.,
STANTONSBURG, NC 27833
SHEET #
ARCH PROJECT # 24-019
DESCRIPTION DATE
1007 Procure Street Fuquay-Varina, NC 27526
919.412.9138 turpentine-design.com
50% REVIEW 08.20.24
90% REVIEW 09.19.24
PRICING 11.27.24
FO
R
PR
IC
IN
G
PU
RP
OS
ES
O
NL
Y
NO
T
FO
R
CO
NS
TR
UC
GENERAL CONSTRUCTION NOTES:
1. ALL WORK SHALL COMPLY WITH THE APPLICABLE LOCAL CODES AND BUILDING RULES AND
REGULATIONS.
2. CM/CONTRACTOR SHALL REVIEW AND STUDY THE CONTRACT DOCUMENTS AND SHALL BE
RESPONSIBLE FOR THE COORDINATION OF THE WORK OF ALL TRADES.
3. CM/CONTRACTOR SHALL ACQUAINT THEMSELVES WITH THE JOB AND VERIFY ALL
DIMENSIONS, EXISTING CONDITIONS, ETC. BEFORE COMMENCING ANY PHASE OF THE WORK.
4. CM/CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY DISCREPANCY BETWEEN THE
DRAWINGS, THESE NOTES AND FIELD CONDITIONS PRIOR TO COMMENCING ANY
DISCREPANCY BETWEEN THE DRAWINGS, THESE NOTES AND FIELD CONDITIONS PRIOR TO
COMMENCING ANY PHASE OF THE WORK.
5. ALL WOOD BLOCKING AND GROUNDS, ARE TO BE FIRE-RETARDANT TREATED AND
CONFORM TO ANY AND ALL BUILDING CODE REQUIREMENTS CONCERNING FIREPROOFING.
6. CM/CONTRACTOR SHALL FURNISH AND INSTALL ALL MATERIALS AS REQUIRED TO PATCH
AND REPAIR EXISTING FINISHES OR PROVIDE NEW FINISHES IN ORDER TO PROVIDE A FINAL
COMPLETE FINISH AFTER ALL DEMOLITION, CHAPPING, REMOVAL, ETC.
7. ALL OPENINGS IN RATED WALLS AND ENCLOSURES SHALL BE PROTECTED WITH FIRE RATED
PROTECTIVE DEVICES AS PER THE LOCAL BUILDING CODE.
8. CM/CONTRACTOR SHALL SUBMIT ALL SHOP DRAWINGS AND/OR SAMPLES FOR ALL
PERTINENT TRADES, INCLUDING WOODWORK, DOORS AND HARDWARE, LIGHTING, ETC. TO
ARCHITECT FOR APPROVAL PRIOR TO COMMENCING WORK.
9. ALL OUTSIDE CORNERS AT DRYWALL PARTITIONS SHALL HAVE CORNER BEADS TAPED AND
SPACKLED. ALL GYPSUM BOARD ABUTTING CEILING TILES AND ELSEWHERE AS INDICATED
SHALL HAVE TAPING "L" BEADS, TAPED AND SPACKLED.
WOOD TRIM (064600)
WORK INCLUDED:
1. INTERIOR WOOD TRIM
MATERIALS
1. INTERIOR TRIM:
A. GRADED IN ACCORDANCE WITH AWI/AWMAC/WI ARCHITECTURAL WOODWORK STANDARDS,
SECTION 3 REQUIREMENTS FOR QUALITY GRADE SPECIFIED, AVERAGE MOISTURE CONTENT OF
6 PERCENT.
B. MAPLE SPECIES, NO. 1 SELECT, OF QUALITY SUITABLE FOR OPAQUE AND TRANSPARENT
FINISHES.
ACCESSORIES
1. FASTENERS: TYPE AND SIZE AS REQUIRED BY CONDITIONS OF USE; PLAIN STEEL FOR INTERIOR
USE; HOT DIP GALVANIZED STEEL FOR EXTERIOR USE.
2. ADHESIVES:
A. WATERPROOF, WATER BASED TYPE, COMPATIBLE WITH TRIM AND SUBSTRATE MATERIALS.
B. MAXIMUM VOLATILE ORGANIC COMPOUND (VOC) CONTENT: 30 GRAMS PER LITER.
C. FASTENERS: TYPE AND SIZE AS REQUIRED BY CONDITIONS OF USE; PLAIN STEEL FOR
INTERIOR USE; HOT DIP GALVANIZED STEEL FOR EXTERIOR USE.
FINISHES
1. FACTORY FINISHING:
A. PAINT OR STAIN AS INDICATED ON DRAWINGS.
EXECUTION
1. PRIOR TO INSTALLATION, CONDITION WOOD TO AVERAGE HUMIDITY THAT WILL PREVAIL
AFTER INSTALLATION.
2. INSTALL IN ACCORDANCE WITH AWI/AWMAC/WI ARCHITECTURAL WOODWORK STANDARDS.
3. INSTALL IN LONGEST PRACTICAL LENGTHS.
4. SET PLUMB AND LEVEL.
5. MITER ENDS, CORNERS, AND INTERSECTIONS.
6. SCRIBE TO ADJACENT CONSTRUCTION WITH MAXIMUM 1/8 INCH GAPS.
7. FASTEN OR ADHERE TO SUPPORTING CONSTRUCTION.
DIVISION 8: DOORS, WINDOWS & GLASS
ALUMINUM DOORS AND FRAMES FOR INTERIOR USE (08110)
STANDARDS:
1. NFPA 80 - STANDARD FOR FIRE DOORS AND WINDOWS.
2. UL BUILDING MATERIALS LIST, JANUARY 1979 EDITION.
3. FIRE-RATED DOOR AND DOOR FRAME ASSEMBLIES (INCLUDING HARDWARE) SHALL CONFORM
TO UL STANDARDS AND LOCAL BUILDING CODES. PLACE UL LABELS WHERE VISIBLE WHEN
DOORS AND FRAMES INSTALLED, OPEN POSITION.
LABELS:
1. COMPLY WITH STANDARDS AND PROVIDE UL LABELS WHERE REQUIRED ON DOORS AND
FRAMES.
QUALITY ASSURANCE:
1. SINGLE SOURCE RESPONSIBILITY: PROVIDE ALUMINUM FRAMES AND ACCESSORIES PRODUCED
BY A SINGLE MANUFACTURER FOR EACH TYPE OF PRODUCT INDICATED.
QUALIFICATION OF INSTALLERS:
1. FOR ACTUAL INSTALLATION OF ALUMINUM DOOR FRAMES WORK, USE ONLY PERSONNEL WHO
ARE THOROUGHLY TRAINED AND EXPERIENCED IN SKILLS REQUIRED AND WHO ARE
COMPLETELY FAMILIAR WITH MANUFACTURER'S CURRENT RECOMMENDATION METHODS OF
INSTALLATION AS WELL AS REQUIREMENTS OF THIS WORK.
DELIVERY, STORAGE AND HANDLING
1. DELIVER FRAMES IN CARTONS TO PROVIDE PROTECTION DURING TRANSIT AND STORAGE AT
PROJECT SITE.
2. INSPECT FRAMES UPON DELIVERY FOR DAMAGE
A. REPAIR MINOR DAMAGE TO PRE-FINISHED PRODUCTS BY MEANS AS RECOMMENDED BY
MANUFACTURER.
B. REPLACE FRAMES THAT CANNOT BE SATISFACTORILY REPAIRED.
3. STORE FRAMES AT PROJECT SITE UNDER COVER AND AS NEAR AS POSSIBLE TO FINAL
INSTALLATION LOCATION. DO NOT USE COVERING MATERIAL THAT WILL CAUSE
DISCOLORATION OF ALUMINUM FINISH.
ENVIRONMENTAL REQUIREMENTS
1. DO NOT BEGIN INSTALLATION OF FRAMES OR DOORS UNTIL AREA OF WORK HAS BEEN
COMPLETELY ENCLOSED AND INTERIOR IS PROTECTED FROM THE ELEMENTS.
2. MAINTAIN TEMPERATURE AND HUMIDITY IN AREAS OF INSTALLATION WITHIN REASONABLE
LIMITS, AS CLOSE AS POSSIBLE TO FINAL OCCUPANCY. IF NECESSARY, PROVIDE TEMPERATURE
CONTROL AND VENTILATION TO MAINTAIN REQUIRED ENVIRONMENTAL CONDITIONS.
SUBMITTALS:
1. SUBMIT THE FOLLOWING IN ACCORDANCE WITH DIVISION 1.
2. SHOP DRAWING SHOWING ELEVATIONS OF EACH DOOR TYPE; DETAILS OF EACH FRAME TYPE;
LOCATION IN THE PROJECT FOR EACH ITEM; CONDITIONS AT OPENINGS WITH VARIOUS WALL
THICKNESS AND MATERIAL; TYPICAL AND SPECIAL DETAILS OF CONSTRUCTION; METHODS OF
ASSEMBLING SECTIONS; LOCATION AND INSTALLATION REQUIREMENTS FOR HARDWARE, SIZE,
SHAPE AND THICKNESS OF MATERIALS; JOINTS AND CONNECTIONS. USE SAME REFERENCE
NUMBERS FOR OPENINGS AS CONTRACT DRAWINGS.
3. INFORMATIONAL SUBMITTALS: SUBMIT MANUFACTURER'S INSTRUCTIONS.
SAMPLES - SUBMIT THE FOLLOWING:
1. SAMPLES INDICATING QUALITY OF FINISH IN SELECTED COLORS ON ALLOYS USED FOR WORK.
2. WHERE NORMAL COLOR AND TEXTURE VARIATIONS ARE EXPECTED, INCLUDE ADDITIONAL
SAMPLES TO SHOW RANGE OF SUCH VARIATION.
COORDINATION AND MEASUREMENT:
1. TAKE ALL NECESSARY MEASUREMENTS AT THE PROJECT SITE TO ASSURE PROPER FITTING
AND FABRICATIONS OF ALL WORK. VARIATIONS OF ADJACENT CONSTRUCTION SHALL BE
TAKEN INTO ACCOUNT AND PROPERLY PROVIDED FOR WORK UNDER THIS SECTION SHALL BE
CLOSELY COORDINATED WITH THAT OF OTHER TRADES WHOSE WORK AFFECTS, OR IS
AFFECTED BY WORK INCLUDED HEREIN. PROVIDE 15% OF THE FRAMES 3" EXTRA LENGTH, NO
ANGLE CLIPS ATTACHED FRAMES TO E UTILIZED IN AREAS WHERE FLOOR VARIES.
2. SECURE TEMPLATES FROM FINISH HARDWARE SUPPLIER AND ACCURATELY INSTALL, OR MAKE
PROVISIONS FOR, ALL FINISHED HARDWARE AT FACTORY.
REQUIREMENTS OF REGULATORY AGENCIES:
1. A. PROVIDE REQUIRED LABELS PERMANENTLY FASTENED ON EACH DOOR AND FRAME
ASSEMBLY WHICH IS WITHIN THE SIZE LIMITATIONS ESTABLISHED BY THE LABELING
AUTHORITY HAVING JURISDICTION.
B. PROVIDE ANCHORS FOR LABELED FRAMES AS REQUIRED BY AUTHORITY HAVING
JURISDICTION.
WARRANTY:
1. WARRANT AGAINST DEFECTS IN MANUFACTURING OF MATERIALS FOR A PERIOD OF 2 YEARS
FROM DATE OF SUBSTANTIAL COMPLETION.
2. WARRANT FRAMING FINISH AGAINST DEFECTS, INCLUDING CRACKING, FLAKING, BLISTERING, PEELING AND EXCESSIVE FADING, CHALKING AND NON-UNIFORMITY IN COLOR FOR A PERIOD
OF 5 YEARS.
MANUFACTURERS:
1. REFERENCE DOOR SCHEDULE FOR APPROVED MANUFACTURERS AND PRODUCTS.
ALUMINUM FRAMES:
1. MATERIALS
A. ALUMINUM: MEETING REQUIREMENTS OF ASTM B221, 6063T5 ALLOY, AND AS OTHERWISE
REQUIRED TO ASSURE COMPLIANCE WITH DIMENSIONAL TOLERANCES AND MAINTAIN COLOR
UNIFORMITY. BILLETS SHALL BE COMPOSED OF AT LEAST 33% RECYCLED ALUMINUM.
B. ANCHORAGE DEVICES, CLIPS AND FASTENERS: MANUFACTURER'S STANDARD TYPE,
COMPATIBLE WITH MATERIALS BEING SECURED.
C. ACCESSORIES AS REQUIRED FOR COMPLETE SYSTEM
2. FABRICATION
A. ASSEMBLE ALL DOOR FRAMES WITH SCREWS UTILIZING INTERNAL SCREW SPLINE SYSTEM,
INSERT INTO THE DRYWALL ROUGH OPENING.
B. DO NOT EXCEED MAXIMUM SIZE OF DOOR TO MEET APPLICABLE CODE REQUIREMENTS.
C. FACTORY PRE-MACHINE DOOR FRAME JAMBS AND PREPARE FOR HARDWARE, WITH
CONCEALED REINFORCEMENT PLATES, DRILLED AND TAPPED AS REQUIRED, AND FASTENED
WITHIN FRAME WITH CONCEALED SCREWS.
5. INSTALLATION
A. SET HOLLOW METAL FRAMES AT LOCATIONS SHOWN, IN PERFECT ALIGNMENT AND
ELEVATION, PLUMB, LEVEL, STRAIGHT, TRUE AND FREE FORM RACK. BRACE FRAMES TO
PREVENT DISPLACEMENT.
B. ANCHOR FRAMES TO FLOORS WITH ANCHOR BOLTS OR WITH DRIVEN FASTENERS.
COORDINATE THE INSTALLATION OF BUILT-IN ANCHORS FOR WALL AND PARTITION
CONSTRUCTION AS REQUIRED WITH OTHER WORK.
C. AFTER WALL CONSTRUCTION HAS BEEN COMPLETED, REMOVE TEMPORARY BRACES.
LEAVE SURFACES SMOOTH AND DAMAGED.
D. INSTALL LABELED FIRE DOORS AND FRAMES TO MEET REQUIREMENTS OF THE INSURANCE
INSPECTION AND RATING BUREAUS HAVING JURISDICTION AT THE PROJECT SITE SO AS TO
AVOID ANY RATE PENALTY. CORRECT ANY INSTALLATION WHICH WOULD SUBJECT THE
OWNER AND TENANT TO A RATE PENALTY.
E. AFTER INSTALLATION, TOUCH-UP SCRATCHED SURFACES. USE TYPE OF PRIMER
RECOMMENDED FOR GALVANIZED SURFACES OR IDENTICAL TO THAT USED FOR SHOP COAT.
WOOD DOORS (08200)
1. PROVIDE EXPOSED WOOD VENEER DOORS OR PAINT-GRADE DOORS AS INDICATED ON
ARCHITECTURAL DRAWINGS.
2. SUBMITTALS: SUBMIT SHOP DRAWINGS IN ACCORDANCE WITH DIVISION 1.
3. SOLID CORE DOORS: FLUSH TYPE, 1-3/4" THICK (MINIMUM, UNLESS OTHERWISE NOTED) SOLID
BLOCK OR STILE AND RAIL CORE. TYPE AS (5PLY) CONSTRUCTION DOORS SHALL BE
PREMIUM GRADE PER AWI STANDARDS. FACE VENEERS OR PAINT SPECIFICATION SHALL BE
AS INDICATED ON DOOR SCHEDULE.
A. PROVIDE SOLID WOOD BLOCKING FOR ALL DOOR HARDWARE SUCH THAT NO
THROUGHBOLT WILL BE REQUIRED TO PERMANENTLY MOUNT HARDWARE ON DOOR. IF
BLOCKING IS NOT PRACTICAL, PROVIDE STAVE-CORE WOOD DOORS.
B. EXECUTION: DOORS SHALL HAVE ALL HANDLING MARKS OR EFFECTS OF EXPOSURE TO
MOISTURE REMOVED WITH THOROUGH, FINAL SANDING OVER ALL EXPOSED SURFACES USING
150 GRIT OR FINER SANDPAPER AND SHALL THEN BE BRUSHED CLEAN.
C. PRIME OR SEAL ALL WOOD DOORS ON ALL SIDES AND EDGES (IMMEDIATELY UPON
DELIVERY TO PROJECT SITE). WHERE ITEMS ARE FURNISHED PREPRIMED, TOUGH UP ALL
ABRASIONS.
4. INSTALLATION
A. HANGING DOORS: ALL DOORS SHALL BE EXPERTLY HUNG AND SHALL FIT SNUG AGAINST
ALL STOPS, FIT ACCURATELY AND HANG FREE FROM HINGE BIND.
B. CLEARANCE: FOR NON FIRE-RATED DOORS PROVIDE CLEARANCES OF 1/8" AT JAMBS AND
HEADS, 1/8" AT MEETING STILES FOR PAIRS OF DOORS, AND 1/4" FROM BOTTOM OF DOOR TO
TOP OF DECORATIVE FLOOR FINISH OR, COVERING UNLESS OTHERWISE NOTED. WHEN
THRESHOLD IS SHOWN OR SCHEDULED, PROVIDE 1/8" CLEARANCE FROM BOTTOM OF DOOR
TO TOP OF THRESHOLD.
C. HARDWARE SHALL BE FITTED PRIOR TO FINISHING AND THEN REMOVED AND FINISHING
COMPLETED BEFORE FINAL INSTALLATION OF HARDWARE. FINISH HARDWARE MUST BE
NEATLY AND PROPERLY INSTALLED IN ACCORDANCE WITH BEST PRACTICES AS PRESCRIBED
BY MANUFACTURERS AND AS APPROVED BY ARCHITECT.
D. NO EXTRA COST WILL BE ALLOWED BECAUSE OF CHANGES OR CORRECTIONS
NECESSARY TO FACILITATE INSTALLATION OF ANY HARDWARE. CONTRACTOR
SHALL BE RESPONSIBLE FOR PROPER FABRICATION OF ALL WORK OR MATERIAL TO
RECEIVE HARDWARE.
DIVISION 8: DOORS, WINDOWS & GLASS (con't)
FINISH HARDWARE (08700)
1. PROVIDE FINISH HARDWARE AS INDICATED ON THE DOOR/HARDWARE SCHEDULE ON
ARCHITECTURAL DRAWING.
2. SUBMITTALS:
A. SUBMIT THE FOLLOWING IN ACCORDANCE WITH DIVISION 1.
B. SCHEDULES: SUBMIT HARDWARE SCHEDULE INDICATING EACH TYPE OF HARDWARE FOR
EACH DOOR; INCLUDING ROOM NUMBERS AND ANY OTHER INFORMATION.
C. SAMPLES: INDICATE REQUIRED STYLE AND FINISH.
D. PRODUCT DATA: SUBMIT MANUFACTURER'S CATALOG CUTS FOR EACH HARDWARE ITEM.
3. HARDWARE ITEMS
A. SEE DOOR SCHEDULE FOR HARDWARE GROUP LOCATIONS AND DOOR TYPES.
B. BUTTS: ALL EXTERIOR OUTSWINGING DOORS SHALL HAVE NONFERROUS BUTTS WITH
NON-REMOVABLE PINS. LABELED DOORS SHALL HAVE STEEL BUTTS. WHERE LABELED
DOORS ARE EXTERIOR OUTSWINGING, PROVIDE STAINLESS STEEL BUTTS. UNLESS
OTHERWISE SPECIFIED, SIZE OF BUTTS WILL BE DETERMINED BY THE FOLLOWING TABLE:
1. SIZE AND TYPE:
a. DOORS 1-3/4" THICK AND UP TO 41" WIDE: 4 1/2" EXTRA HEAVY-WEIGHT
BALLBEARING OR OILITE BEARING.
b. DOORS 2" THICK AND/OR OVER 48" WIDE: 5" EXTRA HEAVY-WEIGHT BALLBEARING OR
OILITE BEARING.
2. PROVIDE WIDTHS SUFFICIENT TO CLEAR TRIM PROJECTION WHEN DOOR SWINGS 180
DEGREES.
3. PROVIDE 2 HINGES TO 60" HIGH, 3 HINGES TO 90" HIGH, 4 HINGES 120" HIGH FOR EACH
DOOR LEAF, UNLESS OTHERWISE SPECIFIED HEREIN.
4. FINISH: MATCH LOCKSET OR LATCHSET, UNLESS OTHERWISE SPECIFIED OR INDICATED.
C. LOCKSETS AND LATCHSETS: PROVIDE HEAVY DUTY MORTISE CASES OF METAL
MATCHING SPECIFIED FINISH; INTERIOR PARTS OF STEEL AND ZINC-DICHROMATIC PLATING TO
RESIST RUSTING AND CORROSION. DO NOT SUPPLY PLASTIC, DIE-CAST OR ALUMINUM
MECHANISMS. CYLINDERS SHALL HAVE FULL ROUND PLUGS OF EXTRUDED BRASS BAR
MATERIAL, AND BE 6-PIN TUMBLER TYPE.
1. FINISH: SEE DOOR SCHEDULE
2. BACKSET: PER MFR. RECOMMENDATIONS
3. STRIKES: PROVIDE STANDARD BOX-TYPE STRIKES; FURNISH WITH EXTENDED LIPS WHERE
REQUIRED TO PROTECT TRIM FROM BEING MARRED BY LATCH BOLT. VERIFY WHETHER
STANDARD OR ANSI CUTOUTS ARE PROVIDED IN METAL FRAMES.
D. KEYS AND KEYING: (BY OTHERS)
1. HARDWARE MANUFACTURERS SHALL KEY AND REGISTER ALL LOCKS, PROVIDING FOR
GRAND MASTER, MASTER KEY ALIKE OR KEY DIFFERENT KEYING AS DIRECTED BY
ARCHITECT.
2. PROVIDE MINIMUM 2 KEYS FOR EACH LOCKSET. COORDINATE FINAL QUANTITIES W/
CLIENT.
3. PROVIDE CONSTRUCTION CYLINDERS FOR DOORS REQUIRING LOCKS DURING
CONSTRUCTION. CONSTRUCTION CYLINDERS SHALL BE REMOVED AND REPLACED JUST PRIOR
TO OWNER OCCUPANCY. KEYS FOR PERMANENT USE SHALL BE SUBMITTED TO OWNER.
E. CLOSERS:
1. FURNISH PRODUCTS OF ONE MANUFACTURER; FULL RACK AND PINION TYPE WITH STEEL
SPRING AND NON-FREEZING HYDRAULIC FLUID. PROVIDE CONTROLS FOR REGULATING
CLOSING, LATCHING, SPEEDS AND BACK CHECK. SPRING POWER ADJUSTMENT WHERE
SPECIFIED. SUPPLY PARALLEL-ARM CLOSERS AT REVERSE BEVEL DOORS AND WHERE
DOORS SWING FULL 180 DEGREES. ARM TYPES SHALL SUIT INDIVIDUAL CONDITIONS, AS
APPROVED. REFER TO DOOR SCHEDULE FOR LOCATION OF CLOSER.
2. DESIGN: ANSI MODERN TYPE WITH COVER, UNLESS OTHERWISE SPECIFIED.
3. SIZES AS RECOMMENDED BY MANUFACTURER AND ADJUSTABLE TO THE FOLLOWING
OPERATING PRESSURES:
4. INTERIOR DOORS: 5 POUNDS.
5. FIRE RATED DOORS: 15 POUNDS.
6. HEX BOLTS AND GROMMET NUTS SHALL BE AVOIDED ON DOOR FACES IN HIGHLY VISIBLE
AREAS, UNLESS NO ALTERNATIVE IS POSSIBLE, AS DIRECTED AND APPROVED, AND SHALL
NOT BE USED FOR SOLID WOOD CORE DOORS.
7. MAKE LABELED DOORS SELF-CLOSING, WITH MAGNETIC HOLDERS AND SMOKE DETECTORS,
WHERE SPECIFIED OR SHOWN ON DRAWINGS.
8. CLOSERS SHALL BE ADJUSTED BY FACTORY REPRESENTATIVE.
9. DOOR STOPS: UNLESS OTHERWISE SPECIFIED, DOME TYPE TO SUIT CONDITIONS. PROVIDE
CARPET RISERS AT CARPETED AREAS.
10. MAGNETIC HOLD-OPEN DEVICES, COORDINATE WITH ELECTRICAL INSTALLATION FOR
HOOK-UP TO SMOKE DETECTOR UNIT WHERE SHOWN.
11. WEATHER-STRIPPING, THRESHOLDS AND DOOR BOTTOMS: PROVIDE WEATHER-STRIPPING
AND DOOR BOTTOMS AS PART OF DOOR ASSEMBLY COMPLETE WITH ALL ACCESSORIES.
FASTENING AND SEALS AS REQUIRED FOR SMOKE PROOF INSTALLATIONS WHERE SHOWN.
12. KICK PLATES: MOUNT ON PUSH SIDE ONLY. SIZE AS PER DOOR WIDTH BY SPECIFIED
HEIGHT.
4. INSTALLATION:
A. CONTRACTOR SHALL INSTALL FINISH HARDWARE AS REQUIRED. HARDWARE SHALL BE
FITTED PRIOR TO PAINTING AND THEN REMOVED AND PAINTING COMPLETED BEFORE FINAL
INSTALLATION OF HARDWARE. FINISH HARDWARE MUST BE NEATLY AND PROPERLY
INSTALLED IN ACCORDANCE WITH BEST PRACTICES AS PRESCRIBED BY MANUFACTURERS
AND AS ACCEPTABLE TO ARCHITECT. ALL HARDWARE MUST BE THOROUGHLY CLEANED
PRIOR TO TURNING PROJECT OVER TO OWNER.
B. NO EXTRA COST WILL BE ALLOWED BECAUSE OF CHANGES OR CORRECTIONS NECESSARY
TO FACILITATE INSTALLATION OF ANY HARDWARE. CONTRACTOR SHALL BE RESPONSIBLE
FOR PROPER FABRICATION OF ALL WORK OR MATERIAL TO RECEIVE HARDWARE.
DIVISION 0: GENERAL CONDITIONS
GENERAL CONDITIONS (00700)
CONFORM WORK TO THE CONTRACT DOCUMENTS WHICH INCLUDE THE
OWNER/CONTRACTOR AGREEMENT. THE DRAWINGS, AND ALL ADDENDA AND
MODIFICATIONS ISSUED BY THE ARCHITECT.
DIVISION 1: GENERAL REQUIREMENTS
SUBMITTALS (01340)
PROCEDURES:
1. PRIOR TO COMMENCING SUBSTANTIAL PORTIONS OF THE WORK, PREPARE A MASTER
SUBMITTAL LOG SHOWING EACH REQUIRED SUBMITTAL AND SPECIFICATION SECTION
NUMBER, THE PROPOSED SCHEDULE AND SEQUENCING OF SUBMITTALS, AND EACH
AFFECTED CONTRACTOR. MAINTAIN THE LOG CURRENT WITH THE PROGRESS OF THE
WORK. PROVIDE A COPY OF THE INITIAL AND UPDATED LOG TO THE ARCHITECT.
2. REVIEW SUBMITTALS AND INDICATE RESULTS OF REVIEW PRIOR TO SUBMITTING TO
ARCHITECT.
3. TRANSMIT EACH ITEM UNDER AIA FORM 810 OR SIMILAR FORM. NUMBER EACH SUBMITTAL
CONSECUTIVELY BASED UPON SPECIFICATION SECTION NUMBERS (I.E. 06400-2, 06400-3,
ETC.). ATTACH OR INCLUDE A COVER OUTING/STAMP SHEET WITH EACH SUBMITTAL IN
APPROVED FORMAT.
A. IDENTIFY PROJECT, CONTRACTOR, SUBCONTRACTOR, MAJOR SUPPLIER, AND
GENERIC NAME OF COMPONENT SYSTEM. ALLOW SPACE ON THE COVER SHEET TO
ACCOMMODATE REQUIRED STAMPS BY EACH REVIEWER. PROVIDE ADDITIONAL SHEETS IF
NECESSARY.
B. IDENTIFY DEVIATIONS FROM DRAWINGS AND SPECIFICATIONS AND INCLUDE A
STATEMENT OF REASON(S) FOR DEVIATION. PROCESS IN ACCORDANCE WITH SECTION
01630.
4. AFTER REVIEW OF SUBMITTAL, REVISE AND RESUBMIT IF SO INDICATED; IDENTIFY
CHANGES MADE SINCE PREVIOUS SUBMITTAL.
5. DISTRIBUTE COPIES OF REVIEWED SUBMITTALS TO CONCERNED CONTRACTORS. INSTRUCT
RECIPIENTS TO PROMPTLY REPORT ANY INABILITY TO COMPLY WITH PROVISIONS.
6. MAKE SUBMITTALS FAR ENOUGH IN ADVANCE OF SCHEDULED INSTALLATION DATES TO
PROVIDE TIME REQUIRED FOR REVIEWS, FOR SECURING NECESSARY APPROVALS, FOR
POSSIBLE REVISIONS AND RESUBMITTALS, AND FOR PLACING ORDERS AND SECURING
DELIVERY.
7. SUBMITTALS PROVIDED FOR WORK AND FOR WHICH NO REQUIREMENT FOR SUBMITTAL IS
STATED IN THE DRAWINGS OR SPECIFICATIONS MAY BE RETURNED WITHOUT REVIEW.
SHOP DRAWINGS
1. SUBMIT DIGITAL COPIES OF ALL SHOP DRAWINGS FOR REVIEW.
2. SHEET SIZE: 8-1/2 X 11 INCHES MINIMUM, 30X42 INCHES MAXIMUM.
PRODUCT DATA
1. MARK EACH COPY TO IDENTIFY APPLICABLE PRODUCTS, MODELS, OPTIONS, AND OTHER
DATA; SUPPLEMENT MANUFACTURER'S STANDARD DATA TO PROVIDE INFORMATION
UNIQUE TO THE WORK.
2. SUBMIT STATED NUMBER OF COPIES FOR PROCESSING, DISTRIBUTION AND RECORD
DOCUMENTATION.
A. FOR DATA INDICATING CHOICES OF COLOR, AND/OR FINISH, PROVIDE "ORIGINALS".
B. ALL OTHER PRODUCT DATA / SUBMITTALS REQUIRING REVIEW TO BE SUBMITTED
DIGITALLY UNLESS OTHERWISE REQUESTED BY TURPENTINE DESIGN.
SUBMITTALS
1. SUBMIT A REASONABLE RANGE OF MANUFACTURER'S STANDARD COLORS, TEXTURES,
SHEENS, AND PATTERNS FOR SELECTION WHERE SPECIFIC PRODUCT REQUIREMENTS HAVE
NOT BEEN STATED OR WHERE SUBSTITUTIONS ARE PROPOSED.
2. SUBMIT SAMPLES TO ILLUSTRATE FUNCTIONAL AND SIGHT-EXPOSED CHARACTERISTICS OF
THE PRODUCT, WITH INTEGRAL PARTS AND ATTACHMENT DEVICES. COORDINATE WITH
SUBMITTAL DATE OF OTHER SECTIONS FOR INTERFACING WORK.
3. INCLUDE IDENTIFICATION ON EACH SAMPLE, GIVING FULL INFORMATION.
4. SUBMIT THREE SETS OF EACH PRODUCT FOR THE ARCHITECTS, PLUS ADDITIONAL SET(S)
REQUIRED BY THE CONTRACTOR.
5. SIZES: UNLESS OTHERWISE SPECIFIED, PROVIDE THE FOLLOWING:
A. PAINT AND LIQUID COATED PRODUCTS: MINIMUM 8-1/2 X 11 INCHES, MAXIMUM 24
INCHES SQUARE; TAPE EDGES OF SAMPLES WHEN GYPSUM BOARD IS USED AS BASE OR
SUBSTRATE.
B. LINEAR PRODUCTS: MINIMUM 6 INCHES LONG, MAXIMUM 24 INCHES LONG.
C. BULK PRODUCTS: CONTAINER LABEL ONLY.
D. PREFABRICATED PRODUCTS: ONE UNIT.
6. FULL SIZE OR ON-SITE SAMPLES OR MOCK-UPS MAY BE USED IN THE WORK UPON
APPROVAL.
MANUFACTURER'S CERTIFICATES AND OTHER/SIMILAR DOCUMENTS
1. SUBMIT DIGITAL COPIES OF CERTIFICATES FOR THE ARCHITECT , PLUS ANY ADDITIONAL
HARD COPIES REQUIRED BY THE CONTRACTOR.
2. INCLUDE SIGNATURE ON EACH COPY.
BACKGROUND DRAWINGS
1. REPRODUCIBLE PDF COPIES OF FLOOR PLAN "BACKGROUNDS" ARE AVAILABLE FROM THE
ARCHITECT, UPON REQUEST FROM THE CONTRACTOR.
2. THESE DRAWINGS CAN BE PROVIDED BY THE ARCHITECT AS AN AID TO THE
CONTRACTOR/S RESPONSIBILITY TO PROVIDE SUBMITTAL DATA ACCURATELY SHOWING
FIELD CONDITIONS. THE ARCHITECT DOES NOT WARRANT ACCURACY OF "BACKGROUND"
DRAWINGS.
SUBSTITUTIONS (01630) REQUESTS FOR SUBSTITUTIONS
1. SUBMIT SEPARATE REQUESTS FOR EACH PRODUCT AND SUPPORT EACH REQUEST WITH:
A. PRODUCT IDENTIFICATION.
B. MANUFACTURER'S LITERATURE.
C. SAMPLES, AS APPLICABLE.
D. NAME AND ADDRESS OF SIMILAR PROJECTS ON WHICH PRODUCT HAS BEEN USED AND
DATE OF INSTALLATION.
2. REASON FOR SUBSTITUTION.
3. ITEMIZE A COMPARISON OF THE PROPOSED SUBSTITUTION WITH PRODUCT SPECIFIED AND
LIST SIGNIFICANT VARIATIONS.
4. SUBMIT DATA RELATING TO CHANGES IN CONSTRUCTION SCHEDULE.
5. NOTE ANY EFFECT OF SUBSTITUTION ON OTHER WORK OR PRODUCTS OR ON SEPARATE
CONTRACTS.
6. INCLUDE ACCURATE COST DATA COMPARING PROPOSED SUBSTITUTION WITH PRODUCT
AND THE AMOUNT OF ANY NET CHANGE IN THE CONTRACT PRICE.
7. SUBSTITUTIONS WILL NOT BE CONSIDERED WHEN:
A. THEY ARE INDICATED OR IMPLIED ON SUBMITTALS WITHOUT A FORMAL REQUEST.
B. ACCEPTANCE WILL REQUIRE SUBSTANTIAL REVISION OF DRAWINGS AND
SPECIFICATIONS.
8. DO NOT ORDER OR PROVIDE SUBSTITUTE PRODUCTS WITHOUT APPROVAL.
9. BURDEN OF PROOF OF MERIT OF PROPOSED SUBSTITUTION IS THE RESPONSIBILITY OF THE
CONTRACTOR.
CONTRACTOR'S REPRESENTATION
1. REQUESTS CONSTITUTE A REPRESENTATION THAT THE PROPOSING PARTY:
A. HAS INVESTIGATED PROPOSED PRODUCT AND DETERMINED THAT IT MEETS OR
EXCEEDS, IN ALL RESPECTS, SPECIFIED PRODUCT, INCLUDING REQUIRED APPROVAL FROM
AUTHORITIES HAVING JURISDICTION.
B. WILL PROVIDE THE SAME WARRANTY FOR SUBSTITUTION AS FOR SPECIFIED PRODUCT.
C. WILL COORDINATE INSTALLATION AND MAKE OTHER CHANGES WHICH MAY BE
REQUIRED FOR WORK TO BE COMPLETE IN ALL RESPECTS.
D. WAIVES CLAIMS FOR ADDITIONAL COSTS WHICH MAY SUBSEQUENTLY BECOME
APPARENT.
DIVISION 6: WOOD & PLASTICS
ROUGH CARPENTRY (061000)
WORK INCLUDED:
1. FIRE-TREATED WOOD BLOCKING IN WALLS AND CEILINGS.
2. SURFACE MOUNTED PLYWOOD PANEL BOARDS.
3. FIRE-RETARDANT TREATMENT.
EXECUTION:
1. CORRELATE LOCATION OF FURRING, NAILERS, BLOCKING, GROUNDS AND SIMILAR SUPPORTS
SO THAT ATTACHED WORK WILL COMPLY WITH DESIGN REQUIREMENTS AND BE PROPERLY
LOCATED.
2. CONSTRUCT MEMBERS OF CONTINUOUS PIECES OF LONGEST POSSIBLE LENGTHS.
3. FIT CARPENTRY WORK TO OTHER WORK. SCRIBE AND COPE AS REQUIRED FOR ACCURATE
FIT.
4. SHIM WITH METAL OR SLATE FOR BEARING ON CONCRETE AND MASONRY SUBSTRATES.
5. SECURELY ATTACH CARPENTRY WORK TO SUBSTRATES BY ANCHORING AND FASTENING
AS REQUIRED BY RECOGNIZED STANDARDS.
A. PROVIDE WASHER UNDER BOLT HEADS AND NUTS IN CONTACT WITH WOOD.
B. NAIL PLYWOOD TO COMPLY WITH RECOMMENDATIONS OF AMERICAN PLYWOOD
ASSOCIATION.
6. FRAMING: COMPLY WITH APPLICABLE RECOMMENDATIONS OF NATIONAL FOREST PRODUCTS
ASSOCIATION REFERENCED STANDARD, FOR FABRICATION AND INSTALLATION.
7. PLYWOOD: COMPLY WITH RECOMMENDATIONS OF AMERICAN PLYWOOD ASSOCIATION (APA)
FOR FABRICATION AND INSTALLATION OF PLYWOOD WORK.
FRAMING AND SHEATHING (061100)
WORK INCLUDED:
1. ROOF AND WALL FRAMING
2. ROOF AND WALL SHEATHING
3. WOOD BLOCKING AND FURRING
EXECUTION:
1. SET MEMBERS LEVEL, PLUMB, AND RIGID.
2. MAKE PROVISIONS FOR ERECTION LOADS, AND FOR TEMPORARY BRACING TO MAINTAIN
STRUCTURE SAFE, PLUMB, AND IN TRUE ALIGNMENT UNTIL COMPLETION OF ERECTION AND
INSTALLATION OF PERMANENT BRACING.
3. PLACE BEAMS, JOISTS, AND RAFTERS WITH CROWN EDGE UP.
4. CONSTRUCT LOAD BEARING FRAMING MEMBERS FULL LENGTH WITHOUT SPLICES.
5. STUD FRAMING:
A. PROVIDE SINGLE BOTTOM PLATE AND DOUBLE TOP PLATES FOR LOAD BEARING
PARTITIONS.
B. PROVIDE SINGLE BOTTOM AND TOP PLATES FOR NON-LOAD BEARING PARTITIONS.
C. ANCHOR BOTTOM PLATES TO CONCRETE STRUCTURE WITH ANCHOR BOLTS.
D. TRIPLE STUDS AT CORNERS AND PARTITION INTERSECTIONS.
E. FRAME OPENINGS WITH DOUBLE STUDS AND HEADERS. SPACE SHORT STUDS OVER AND
UNDER OPENING TO STUD SPACING.
6. PROVIDE BLOCKING, NAILERS, GROUNDS, FURRING, AND OTHER SIMILAR ITEMS REQUIRED TO
RECEIVE AND SUPPORT WORK.
7. PROVIDE ADEQUATE BLOCKING FOR ALL WALL-MOUNTED UNITS IN ACCORDANCE WITH
PLANS.
TOLERANCES:
1. FRAMING MEMBERS: 1
4" FROM TRUE POSITION, MAXIMUM.
CABINETWORK AND ARCHITECTURAL WOODWORK (064100)
1. PROVIDE SHOP FABRICATED CABINETWORK AND ARCHITECTURAL WOODWORK ITEMS
COMPLETE WITH HARDWARE ACCESSORIES, AS INDICATED ON ARCHITECTURAL DRAWINGS.
2. ALL CABINETWORK AND ARCHITECTURAL WOODWORK INDICATED ON ARCHITECTURAL
DRAWINGS SHALL BE FABRICATED IN ACCORDANCE WITH THE CURRENT STANDARDS OF
"ARCHITECTURAL WOODWORK INSTITUTE" (AWI), INCLUDING WOOD SELECTION, JOINERY,
SIZING FASTENING AND SHOP FINISHING AS FOLLOWS:
A. "CUSTOM GRADE" FOR PLASTIC LAMINATE OR OPAQUE FINISHED MILLWORK FINISHES AS
INDICATED ON THE DRAWINGS.
B. "HIGH PRESSURE LAMINATE AS AN ARCHITECTURAL WOODWORK MATERIAL"
REFERENCED FOR PLASTIC LAMINATE MILLWORK.
C. "PREMIUM GRADE" FOR EXPOSED WOOD VENEER MILLWORK.
3. PROVIDE FIRE RETARDANT TREATED WOOD WHERE REQUIRED BY THE 2018 NC STATE
BUILDING CODE.
4. SUBMITTALS:
A. SUBMIT THE FOLLOWING IN ACCORDANCE WITH DIVISION 1, SECTION 01340.
B. SUBMIT SHOP DRAWINGS FOR ALL ARCHITECTURAL WOODWORK INCLUDING
DIMENSIONED PLANS, ELEVATIONS, CROSS-SECTIONS, AND LARGE-SCALE DETAILS OF
CONSTRUCTION TO ARCHITECT FOR REVIEW PRIOR TO FABRICATION. SHOP DRAWINGS
SHALL INDICATE MATERIALS AND WOOD SPECIES, COMPONENT PROFILES, FASTENING,
JOINTING, FINISHES, HARDWARE AND ACCESSORIES; AND ADJACENT WORK OF OTHER
TRADES.
C. SUBMIT 3 (THREE) SAMPLES OF ALL ARCHITECTURAL WOODWORK FINISHES TO
ARCHITECT FOR REVIEW AND ACCEPTANCE PRIOR TO FABRICATION.
D. SUBMIT CERTIFICATION OF FIRE-RETARDANT TREATMENT OF WOOD STATING NAME OF
FIRE-RETARDANT MATERIALS USED AND COMPLIANCE WITH AWPA SPECIFICATIONS.
5. PROTECT ALL ARCHITECTURAL WOODWORK ITEMS DURING TRANSIT, DELIVERY, STORAGE
AND HANDLING TO PREVENT DAMAGE, SOILING AND DETERIORATION. THE WOODWORK
CONTRACTOR AND GENERAL CONTRACTOR SHALL BE JOINTLY RESPONSIBLE TO MAKE
CERTAIN THAT WOOD WORKING IS DELIVERED UNTIL PAINTING, WE WORK AND SIMILAR
OPERATIONS WHICH COULD DAMAGE FINISH WORK HAVE BEEN COMPLETED.
6. CONTRACTOR SHALL HAVE EXAMINED THE JOB SITE IN CONJUNCTION WITH PROJECT
DOCUMENTS SO AS TO BE SATISFIED AS TO THE CONDITIONS UNDER WHICH THE WORK
WILL BE PERFORMED, INCLUDING SUCH MATTERS AS UNLOADING FACILITIES AND ANY
OTHER CONDITIONS NEEDED PRELIMINARY TO AND DURING THE WORK.
7. WOODWORK CONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING OF ANY
DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS AND SHALL NOT PROCEED
WITH THE PORTION OF WORK IN QUESTION UNTIL THE DISCREPANCIES ARE CLARIFIED.
MATERIALS:
A. PLASTIC LAMINATE COLOR, MANUFACTURER, AND FINISH AS DESIGNATED ON FINISH
PLANS, SHALL BE OF THE FOLLOWING TYPES FOR SPECIFIC APPLICATION, CONFORMING TO
NEMA LD-3 AND ARCHITECT APPROVED SAMPLES. ADHESIVE: CONTACT TYPE TO BE AS
RECOMMENDED BY MANUFACTURER TO SUIT APPLICATION.
B. EXPOSED WOOD VENEER SPECIES, STAIN COLOR, FINISH AND MATCHING SHALL BE
DESIGNATED ON FINISH SCHEDULE. PROVIDE THE FOLLOWING MATCH AND
ASSEMBLY FOR CONTINUOUS SEQUENTIAL USE OF FLITCHES OR EACH SEPARATE EXPANSE
OF MATCHED WORK AS INDICATED (i.e. PANELS, DOORS & CASEWORK).
1. HORIZONTAL MATCH: REFER TO FINISH SCHEDULE.
2. VERTICAL MATCH: END MATCH.
3. ASSEMBLY: REFER TO FINISH SCHEDULE AND INTERIOR ELEVATIONS.
8. CABINET HARDWARE AND RELATED ACCESSORIES SHALL BE INDICATED ON INTERIOR
ELEVATIONS AND MILLWORK DETAILS.
9. JUST PRIOR TO OWNER ACCEPTANCE, REMOVE PROTECTIVE COVERING, TOUCH UP AS
REQUIRED, WIPE CLEAN, ADJUST AND LUBRICATE HARDWARE, AND CHECK FOR PROPER
OPERATION OF ALL ITEMS. COORDINATE THIS WITH THE GENERAL CONTRACTOR.
3. FINISHES
A. FACTORY FINISH EXTRUDED FRAME AND DOOR COMPONENTS SO THAT ALL PARTS
EXPOSED TO VIEW UPON COMPLETION OF INSTALLATION ARE UNIFORM IN FINISH AND
COLOR. EXPOSED SURFACES SHALL BE FREE OF SCRATCHES AND OTHER SERIOUS
BLEMISHES.
B. FINISH SHALL MATCH EXISTING TENANT STANDARD.
4. WORKMANSHIP
A. FINISHED WORK SHALL BE STRONG AND RIGID, SMOOTH AND NEAT IN APPEARANCE,
SQUARE, TRUE, AND FREE OF DEFECTS, WARP, AND BUCKLE. CORNER BENDS SHALL HAVE
MINIMUM RADII FOR THE GAUGES OF METAL USED.
B. EXAMINE PROJECT CONDITIONS AND VERIFY THAT PROJECT IS READY FOR WORK OF
THIS SECTION TO PROCEED. DO NOT PROCEED WITH INSTALLATION UNTIL UNSATISFACTORY
CONDITIONS HAVE BEEN CORRECTED.
C. VERIFY WALL THICKNESS DOES NOT EXCEED MANUFACTURER'S RECOMMENDED
TOLERANCES OF SPECIFIED THROAT SIZE.
5. INSTALLATION
A. COMPLY WITH FRAME AND DOOR MANUFACTURER'S PRINTED INSTALLATION
INSTRUCTIONS AND APPROVED SHOP DRAWINGS. DO NOT ATTEMPT INSTALLATION IN
AREAS WHERE WALL THICKNESS EXCEEDS TOLERANCES OF SPECIFIED THROAT SIZE.
B. INSTALL FRAMES PLUMB AND SQUARE, FREE FROM WARP OR TWIST, SECURELY
ANCHORED TO SUBSTRATES WITH FASTENERS RECOMMENDED BY FRAME MANUFACTURER.
MAINTAIN DIMENSIONAL TOLERANCES AND ALIGNMENT WITH ADJACENT WORK. ENSURE
JOINTS ARE HAIRLINE TIGHT AND SURFACES FLUSH WITH ADJACENT COMPONENTS.
6. ADJUSTING AND CLEANING
A. PROTECT EXPOSED PORTIONS OF ALUMINUM SURFACES FROM DAMAGE BY PLASTER,
LIME, ACID, CEMENT AND OTHER CONTAMINANTS.
B. TOUCH UP MARRED AREAS SO THAT TOUCH UP IS NOT VISIBLE FROM A DISTANCE OF 4
FEET. REMOVE AND REPLACE FRAMES THAT CANNOT BE SATISFACTORILY ADJUSTED.
7. PROTECTION
A. PROTECT AS REQUIRED TO ASSURE THAT FRAMES AND DOORS WILL BE WITHOUT
DAMAGE UNTIL SUBSTANTIAL COMPLETION.
DIVISION 8: DOORS, WINDOWS & GLASS
HOLLOW METAL DOORS AND FRAMES (08110)
WORK INCLUDED:
1. HOLLOW METAL DOORS AND FRAMES.
2. DRILLING AND REINFORCEMENT TO RECEIVE HARDWARE.
3. SHOP PRIMING.
STANDARDS:
1. ANSI A250.7 - STANDARD NOMENCLATURE FOR STANDARD STEEL DOOR AND STEEL
FRAMES.
2. CS242-62 U.S. DEPARTMENT OF COMMERCE COMMERCIAL STANDARD.
3. NFPA 80 - STANDARD FOR FIRE DOORS AND WINDOWS.
4. UL BUILDING MATERIALS LIST
5. STEEL DOORS, FRAMES, AND TIER INSTALLATION SHALL CONFORM WITH SD-100 AND
NAAMM.
6. FIRE-RATED DOOR AND DOOR FRAME ASSEMBLIES (INCLUDING HARDWARE) SHALL
CONFORM TO UL STANDARDS AND LOCAL BUILDING CODES. PLACE UL LABELS WHERE
VISIBLE WHEN DOORS AND FRAMES INSTALLED, OPEN POSITION.
LABELS:
1. COMPLY WITH STANDARDS AND PROVIDE UL LABELS WHERE REQUIRED ON DOORS AND
FRAMES.
QUALIFICATIONS:
1. PROVIDE DOORS AND FRAMES MANUFACTURED BY A FIRM SPECIALIZING IN THE
PRODUCTION OF HOLLOW METAL WORK.
QUALIFICATION OF INSTALLERS:
1. FOR ACTUAL INSTALLATION OF HALLOW METAL WORK, USE ONLY PERSONNEL WHO ARE
THOROUGHLY TRAINED AND EXPERIENCED IN SKILLS REQUIRED AND WHO ARE
COMPLETELY FAMILIAR WITH MANUFACTURER'S CURRENT RECOMMENDATION METHODS OF
INSTALLATION AS WELL AS REQUIREMENTS OF THIS WORK.
SUBMITTALS:
1. SUBMIT THE FOLLOWING IN ACCORDANCE WITH DIVISION 1.
2. SHOP DRAWING SHOWING ELEVATIONS OF EACH DOOR TYPE; DETAILS OF EACH FRAME
TYPE; LOCATION IN THE PROJECT FOR EACH ITEM; CONDITIONS AT OPENINGS WITH
VARIOUS WALL THICKNESS AND MATERIAL; TYPICAL AND SPECIAL DETAILS OF
CONSTRUCTION; METHODS OF ASSEMBLING SECTIONS; LOCATION AND INSTALLATION
REQUIREMENTS FOR HARDWARE, SIZE, SHAPE AND THICKNESS OF MATERIALS; JOINTS AND
CONNECTIONS.
COORDINATION AND MEASUREMENT:
1. TAKE ALL NECESSARY MEASUREMENTS AT THE PROJECT SITE TO ASSURE PROPER FITTING
AND FABRICATIONS OF ALL WORK. VARIATIONS OF ADJACENT CONSTRUCTION SHALL BE
TAKEN INTO ACCOUNT AND PROPERLY PROVIDED FOR WORK UNDER THIS SECTION SHALL BE
CLOSELY COORDINATED WITH THAT OF OTHER TRADES WHOSE WORK AFFECTS, OR IS
AFFECTED BY WORK INCLUDED HEREIN. PROVIDE 15% OF THE FRAMES 3" EXTRA LENGTH, NO
ANGLE CLIPS ATTACHED FRAMES TO E UTILIZED IN AREAS WHERE FLOOR VARIES.
2. SECURE TEMPLATES FROM FINISH HARDWARE SUPPLIER AND ACCURATELY INSTALL, OR MAKE
PROVISIONS FOR, ALL FINISHED HARDWARE AT FACTORY.
REQUIREMENTS OF REGULATORY AGENCIES:
1. A. PROVIDE REQUIRED LABELS PERMANENTLY FASTENED ON EACH DOOR AND FRAME
ASSEMBLY WHICH IS WITHIN THE SIZE LIMITATIONS ESTABLISHED BY THE LABELING
AUTHORITY HAVING JURISDICTION.
B. PROVIDE ANCHORS FOR LABELED FRAMES AS REQUIRED BY AUTHORITY HAVING
JURISDICTION.
HOLLOW METAL FRAMES:
1. MATERIALS
A. SHEET STEEL FOR FRAMES: ASTM A366, COLD ROLLED, PICKLED AND OILED, PRIME
QUALITY FULLY ANNEALED, STRETCHER LEVELED 16 GAUGE STEEL WITH CLEAN, SMOOTH
SURFACE, FREE…
This is the start of the file's text. The full file is on GovTribe.