23Q0122_ATCH 1_Pricing_Technical_Prior Experience.xlsx

XLSX spreadsheet 143 KB Posted

Attached to
Wet Gap Eddy Current Engine Dynamometers with Instrumentation Accessories Federal contract opportunity
Solicitation number
47QSWC23Q0122
Issued by
GSA Federal Acquisition Service

About this file

This document contains a pricing spreadsheet, technical specifications matrix, and prior experience questionnaire for Wet Gap Eddy Current Engine Dynamometers with Instrumentation Accessories. The solicitation is seeking two wet gap eddy current engine dynamometers rated at 275HP and 8,000RPM each, along with associated testing and measurement instrumentation including a data acquisition system, pressure and thermocouple input channels, interface accessories, and optional items. Responses are required in the provided templates which collect pricing, technical compliance, and descriptions of prior experience delivering similar equipment. The solicitation number is 47QSWC23Q0122 and is issued by GSA Federal Acquisition Service. Delivery and installation is required at Marine Corps Logistics Base Albany, GA within 30 weeks of award.

View the file

Other files for this federal contract opportunity

Other files attached to Wet Gap Eddy Current Engine Dynamometers with Instrumentation Accessories, newest first.
File Type Posted
RFQ 23Q0122 MDMC Dynamometers_Final.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SECT 1 Pricing Wksht 47QSWC23Q0122 - MDMC Wet Gap Eddy Current Engine Dynamometers with Instrumentation Accessories Section 1: Pricing Spreadsheet

Item #Original Equipment ManufacturerProduct NumberProduct DescriptionU/IQtyCountry of OriginMSRPHistorical PaidQuoted Price
Unit Price
(FOB Destination)Unit Price
(FOB Destination)Unit Price
(FOB Destination)Extension Price

(FOB Destination)

1Wet Gap Eddy Current Engine Dynamometers with Instrumentation AccessoriesEA2$ - 0
Total Quoted Aggregate Price:$ - 0

SECT 2 Technical Compliance

47QSWC23Q0122 - MDMC Wet Gap Eddy Current Engine Dynamometers with Instrumentation Accessories
Section 2: TECHNICAL COMPLIANCE MATRIX
Quoter to complete responses within the blue fields
SPECIFICATION / SALIENT CHARACTERISTICS
(NOTE: CHANGING ANY INFORMATION IN THIS COLUMN WILL INVALIDATE YOUR OFFER!!!!!)QUOTER'S SPECIFICATION / SALIENT CHARACTERISTIC (Select from Drop Down if proposed solution meets, does not meet, or exceeds required specifications)QUOTER'S QUOTE REFERENCE (Provide Page Number, Section/Paragraph of quote that meets or exceeds required specifications)COMMENTS (If proposing different specifications, provide a detailed explanation for how proposed speciifcation lacks or exceeds the Government's requirements.
Scope of Work
The contractor shall provide all labor, tools, materials, equipment, safety measures, supervision and all associated permits and services to complete the work to furnish, install, and start-up of two (2) fully functional dynamometer systems at MCLB Albany, GA. (B2224).MEETS
Contractor will be responsible for connecting system to base power. (Customer will provide utilities (electrical power and plant air) within 50' of equipment.DOES NOT MEET
Contractor shall be responsible for due diligence. Customer will provide basic building/shop layouts, site visits, other information as necessary upon requestEXCEEDS
Contractor will be responsible for System start-up and functions check. System start-up will include a check of the final connections as necessary, commissioning,

calibration, and operator training on the equipment purchased. The training will cover basic system functionality including running pre-written automated tests (as applicable) and manual system operation. Connecting other devices, Service startup/training will be 40 hours per Dynamometer system

Final inspection per government end user acceptance.
Equipment Description per Dynamometer
EDDY CURRENT ENGINE DYNAMOMETER, WET GAP,
275HP (205KW), 8,000RPM, 110V COIL
Load cell and linkage
Speed sensor with 60-tooth tach gear
Coolant safety system
Calibration arm and weight hanger (no weights)
Dynamometer hub / companion flange: 1410
Dynamometer shaft centerline height: 16in (406mm)
TESTING AND MEASUREMENT INSTRUMENTATION FOR ENGINE DYNAMOMETERS
Silver
A Data Acquisition & Control System that is customizable
Adaptable to meet our testing requirements
Sophisticated graphical and numerical data analysis tools
Convenient, centralized management of all test data, notes, documents and other information
Fully configurable, with built-in, full-featured programmable language
System Channel list
Eight (8), Pressure input channels with dual LCD display
1 ea. 0-20psia
1 ea. 0-75psia
4 ea. 0-150psia
1 ea. 0-200psia
1 ea. 0-500psia
Sixteen (16), Thermocouple input channels (Type K) with dual LCD display Connections for: Dyno, Speed, Throttle, Digital Inputs, Analog Inputs, Frequency inputs, Fuel

Measurement, Blow- by, Weather Station, Opacity, Network and Peripheral connections

Instrumentation Accessories
JUNCTION BOX RETROFIT KIT, TANDEM ENGINE/CHASSIS, DP2
EDDY CURRENT PAU,6 AMP, wall mount, STD TEMP, FUSED for 208 P, 240 S, 200VDC OUT, 1.5 KVA XFRMR, 60 HZ
PEDESTAL, 48IN TALL, 350 DEGREE SWIVEL, STATIONARY, DP2
THROTTLE CONTROL INTERFACE, 0-20mA, DP2, 25 FT LG
THROTTLE CONTROL INTRFACE, 0-10 VDC, DP2, 25 FT LG LEADS
THROTTLE CONTROL INTERFACE, 100-2,000 HZ, DP2, 25 FT LONG
THROTTLE CONTROL INTERFACE, 0-500 HZ, DP2, 25FT LG
THROTTLE CONTROL INTERFACE, PWM, DP2, 25 FT LG (PULSE WIDTH MODULATION)
MPID INTERFACE, J1708, J1939, OBDII,25'ENG, DP2 Designed to work with testing and measurement system. This system provides electronic engine communications.
Supported communications protocols
SAE 1708/J1587 • SAE J1939
SAE J1850 VPW • SAE J1850 PWM
SAE J2284 / ISO 15765(CAN) • ISO 9141-2
ISO 14230-4 (KPW2000)
Provides a 25ft (7.6m) connecting cable
TEMP CHANNEL CABLE KIT, K TYPE TC, 4x 25’, ENG, DP2 Includes
Four (4), 25ft (7.62m) Extension cables
Four (4), Type K thermocouples
Four (4), Fittings with low and high temp ferrules
PRESSURE CHANNEL HOSE KIT, 25’, 3LO, 1HI TEMP, ENG, DP2 Includes
Three (3),25ft (7.62m) low temperature polymeric core tube with a fiber reinforcement and abrasion-resistant black urethane cover
One (1),25ft (7.62m) High temp stainless steel hoses with a Type 2 silicone rubber composite sleeve
HANDHELD, Tablet with i5 processor, 8GB RAM, 256GB SSD, Bluetooth, Dual Camera with Windows 10 & PROTECTIVE COVER
ESTOP BUTTON KIT, 4 BUTTONS, DP2 Includes
Four (4) E-Stop buttons
1000ft (305m) of cable, connectors, cable tester and crimp tool
WEATHER STATION, NO CABLE, ENG, DP2 Includes
Mounts directly to testing and measurement instrumentation enclosure
Relative humidity
Ambient temperature
IGNITION POWER SUPPLY, 12VDC 24VDC ADDON, 30'CABLE (Not to be used as a power supply for electric starters)
ADVANCED CAL KIT NO WEIGHTS Includes
Pressure/ Vac Calibrator with Gauges
Thermocouple Simulator
Electrical requirements: 115VAC / 1ph / 60Hz and 208V / 3-ph / 60Hz AC voltage.
General Requirements
Contractor shall cleanup work sites daily and properly dispose of debris off Government property
The work shall be performed in such a manner as to cause the least interference with the normal functions of the Government activity. Work areas will be cleared/vacated for the period necessary for the Contractor to perform work; however, the building will be occupied during work.
Prior to beginning any work, the Contractor shall meet with the designated Government representative to discuss and develop mutual understandings relative to scheduling and administering work. All work shall be accomplished within 30 weeks after date of award. This completion time includes 14-day period for checking background of the contractor’s personnel prior to arrival to start work on Base. All asbestos abatement and removal shall be accomplished on weekends and holidays (only if asbestos is found during the project). All other work shall be accomplished between the hours of 8:00 a.m. and 5:00 p.m., Monday thru Friday (excluding federal holidays) unless otherwise specified in the requirements section and specifically pre-arranged with the Contracting Officer. This requires a written request two (2) days prior to proposed work.
Work shall be accomplished by personnel experienced in their respective trades. The Contractor shall perform all work in accordance with acceptable industry standards and all federal, state, and local codes.
All work requiring energy (electrical, mechanical, hydraulic, pneumatic, chemical, thermal or other) removal shall be done in compliance with OSHA 29 CFR 1910.147 and 1910.333 lock-out/tag-out procedures for worker protection. No work will be performed on energized electrical circuits unless proof is provided that no other means exist. NFPA 70E (current edition), Standard for Electrical Safety in the Workplace, shall also be utilized for worker safety compliance.
Except where specifically specified otherwise herein, all salvable materials and equipment disconnected or removed during the work and not indicated or specified for reuse on the new work shall remain the property of the Government. All recyclable materials such as metals, pipes, pumps, engines, motors, and certain electrical components, to include switch gear, MCCs, conduit, copper wire, distribution and control panels, nuts, bolts, washers, old motor starters, obsolete breakers, cable lugs, conduit, conduit fittings, connection boxes, etc. will be recycled in accordance with MCO 5090.2A through the base Qualified Recycling Program (QRP). Remaining material shall be removed from the Government property. Contractor will disassemble or cut recyclable material to fit into roll-off containers or on flat bed trailers. With no part of the items hanging off the trailers or protruding out of the top of the containers.
Prior to performing "Hot Work" (welding, cutting, etc.) or operating other flame-producing/spark producing devices, a written permit shall be requested from the Fire Division. CONTRACTORS ARE REQUIRED TO MEET ALL CRITERIA BEFORE A PERMIT IS ISSUED. The Contractor will provide at least two (2) ten (10) pound 4A:80 BC rated extinguishers for normal "Hot Work". All extinguishers shall be current inspection tagged, approved safety pin and tamper resistant seal. It is also mandatory to have a designated FIRE WATCH for any "Hot Work" done at this activity. The Fire Watch shall be trained in accordance with NFPA 51B and remain on-site for a minimum of 1 Hour after completion of the task or as specified on the hot work permit. When starting work in the facility, Contractors shall require their personnel to familiarize themselves with the location of the nearest fire alarm boxes and place in memory the EMERGENCY FIRE phone number 229-639-5911. ANY FIRE, NO MATTER HOW SMALL, SHALL BE REPORTED TO 229-639-5911 IMMEDIATELY.
Note: Any deviation from the above described equipment, characteristics and requested delivery and installation shall be noted in the Quoter's Technical Discussion and equipment, specifications and delivery as well as detailed descriptions of any added value or benefit to the Government.

SECT 3A Prior Exp Questions

47QSWC23Q0122 - MDMC Wet Gap Eddy Current Engine Dynamometers with Instrumentation Accessories - Section 3A: Prior Experience Worksheet
Please complete this workbook in its entirety, to be submitted for consideration. Quoter to complete all blue cells.
Question No.Prior Experience QuestionsPrior Experience Responses
1How long has your firm been in business? (Limit response to no more than 50 words.)

2 How many contracts/task orders has your firm successfully performed within the past three (3) years? (Limit response to no more than 300 words)

3 How many contracts/task orders has your firm successfully performed within the past three (3) years that have involved Wet Gap Eddy Current Engine Dynamometers with Instrumentation Accessories? Please list your five (5) largest contracts/task orders. (Limit response to no more than 300 words)

4a How many contracts/task orders has your firm successfully performed within the past three (3) years that have involved providing Wet Gap Eddy Current Engine Dynamometers with Instrumentation Accessories? Please list the relevant performance location information. (Limit response to no more than 350 words)

4b Please describe any difficulties/constraints you encountered providing support for the contracts/task orders described in Question 4a and what steps your firm took to overcome those challenges. (Limit response to no more than 350 words)

5 Has your firm earned any industry awards? If so, please list and provide description of award and why your firm received this recognition. (Limit response to no more than 300 words. If necessary, limit list of awards to those that are most relevant to this requirement)

6 How would your firm's Prior Experience provide value to the Government for this requirement? (Limit response to no more than 350 words)

7 How would your firm's Prior Experience mitigate risks to the Government for this requirement? (Limit response to no more than 350 words)

SECT 3B Prior Exp Projects

47QSWC23Q0122 - MDMC Wet Gap Eddy Current Engine Dynamometers with Instrumentation Accessories - Section 3B: Prior Experience Worksheet
Please complete this workbook in its entirety, to be submitted for consideration. Quoter to complete all blue cells.
PE #1PE #2PE #3
1Quoter Name

2 Quoter UEI Number

3 Contract Number

4 Task Order Number

5 SCHEDULE/GWAC/OASIS Name, if applicable

6 Contract Type

7 Title of Requirement

8 Customer/Agency that Requirement is for

9 Award Date

10 Client POC Name

11 Client POC Email Address

12 Within 3 years of this RFQ (Y/N)?

13 Period of Performance (PoP)

14 Does this project have at least one yearly CPARS assessment completed?

15 Total Contract $$ Value

16 Quoter's Role (Prime or Sub)

17 If Sub-contractor, what percent of project value was completed by your firm?

18Equipment
Did this experience include providing any of the equipment as stated in Section C of the RFQ?
If yes, please describe equipment provided and how they are relevant to this requirement in no more than 350 words

File details come from the government source that posted it. Updated .