Questions and Answers Sources Sought.pdf

PDF 64 KB Posted

Attached to
Three (3) Heat Treat Furnaces for aerospace parts.
Solicitation number
23-40-1000
Issued by

About this file

This document contains the Questions and Answers for a Sources Sought notice related to a federal contract opportunity for Three (3) Heat Treat Furnaces for aerospace parts.

The key details are:

  • The Sources Sought notice for Solicitation Number 23-40-1000 has been extended until COB 14 August 2024 to provide answers to vendor questions.
  • The furnaces must be equipped with specific Eurotherm, Honeywell, and Yokogawa controllers and recorders to meet AMS 2750 requirements for temperature accuracy and control.
  • The furnace chamber dimensions are provided, with Furnace #1 and Furnace #2 at 13 ft x 3.75 ft x 2 ft, and Furnace #3 at 13 ft x 9.5 ft x 6 ft.
  • Acceptance testing procedures are detailed, requiring temperature deviation limits of +/- 10°F or +/- 25°F depending on the temperature range.
  • The contract is being issued by the Defense Logistics Agency Aviation for Tinker Air Force Base.
  • Interested parties are instructed to submit responses by 12 August 2024 to the AVN IPE Market Research email address.

View the file

Other files

File Type Posted
SOURCES SOUGHT Synopsis.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1. The sources sought for 23-40-1000, Three (3) Heat Treat Furnaces for aerospace parts will be extended until COB 14 August 2024. The purpose of this extension is to provide answers to questions:

Vendor Questions:

1. What is the working volume of each heat treatment oven chamber?

2. Can you confirm the heating method for each chamber, i.e. Radiant Heating or Convection Heating?

Answer to Questions:

1. All furnaces are radiant heat

2. The furnaces chamber dimensions are as follows

a. Furnace #1: 13 ft x 3.75 ft x 2 ft

b. Furnace #2: 13 ft x 3.75 ft x 2 ft

c. Furnace #3: 13 ft x 9.5 ft x 6 ft

2. Please direct any questions to Christina Petrone at Christina.Petrone@dla.mil.

mailto:Christina.Petrone@dla.mil