_2336_A Addendum 5.pdf

PDF 2 MB Posted

Attached to
2336-A Lake Kedron Dam Intake Sluice Gate
Solicitation number
PE-65600-NONST-2024-000000018
Issued by
Douglas County, Georgia

About this file

This document is an Addendum 5 to a Request for Quotes (RFQ) issued by the Fayette County, Georgia Purchasing Department for the Lake Kedron Dam Intake Sluice Gate project. The addendum provides responses to questions and clarification on specification details, including the distance from the operating floor to the handwheel centerline (36.5"), the dimensions of the existing cutout (25" x 2.25"), and confirmation that the specified leakage rate is 0.5 gpm per foot of seating perimeter. The RFQ dates were previously updated in earlier addenda, with the questions due date of November 7, 2023 and quotes due by 3:00 pm on November 14, 2023.

The addendum notes that if the document is not returned signed, respondents will still be responsible for the requirements and changes outlined. Interested parties are instructed to contact the Contract Administrator, Natasha Duggan, with any further questions.

View the file

Other files

File Type Posted
_2336_A Addendum _1.pdf PDF
_2336_A Pre_quote sign in sheet.pdf PDF
_2336_A Addendum 2.pdf PDF
_2336_A Addendum 3.pdf PDF
_2336_A RFQ.pdf PDF
_2336_A Addendum 4.pdf PDF
_2336_A Tally Sheet.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FAYETTE

Create Your Story!

November 7, 2023

Purchasing Department

140 Stonewall Avenue West, Ste 204 Fayetteville, GA 30214 Phone: 770-305-5420 www.fayettecountyga.gov

Subject: Request for Quotes 2336-A: Lake Kedron Dam Intake Sluice Gate

Addendum 5

Gentlemen/Ladies:

Below, please find responses to questions, clarification, or additional information for the above referenced Request for Quote. You will need to consider this information when preparing your quote.

1. Please provide the distance from the operating floor at the inside of the Intake Structure (where we were all standing on 11/2/23) to the centerline of the cutout where the handwheel will protrude.

36.5"

2. Also provide the opening dimensions of the existing cutout (length x height).

25" X 2.25"

3. Specifications part 2.1 specify leakage rate at 0.5 gpm per foot of seating perimeter. Can you confirm that is correct or is it meant to be 0.05 gpm?

It is as written - 0.5 gpm per foot of seating perimeter.

Received by (Name): __________ _ Company _________ _

Note: If this addendum is not returned to the Fayette County Purchasing Department or if it is returned not signed, responding individuals or companies will still be responsible for the requirements of this addendum and the specifications or changes herein.

The dates for this RFQ were changed in previous addenda as follows:

a. Addendum 1 changed the pre-quote meeting to 9:00 a.m. on Thursday, November 2, 2023

b. Addendum 2 changed the questions due date to 3:00 p.m., Tuesday, November 7, 2023

c. Addendum 2 changed the quotes due: 3:00 p.m., Tuesday, November

14, 2023

Quotes must be received by the Purchasing Department at the address above, Suite 204, at or before the opening date and time.

If you have questions, please contact Natasha Duggan, Contract Administrator at (770) 305-5150, fax

(770) 719-5534 or email at nduggan@fayettecountyga.gov.