23125-1000 CASD Early Elem Kitchen - Bids - Dwgs - 02-02-2024 PART 2.pdf

PDF 1 MB Posted

Attached to
KITCHEN RENOVATION
Solicitation number
RFP - CAP - 240000001172
Issued by
Genesee County, Coldwater City, Michigan

About this file

This document is a set of construction drawings and specifications for a kitchen renovation project for the Clio Area School District located in Clio, Michigan. The project involves the demolition and replacement of the existing kitchen, including the removal and reinstallation of HVAC, plumbing, and electrical systems. The drawings provide details on the proposed layout, equipment, and building systems. Key details include a floor plan, demolition plan, piping plan, and various equipment schedules. The project is scheduled for bidding on February 2, 2024, with a quality management review on June 30, 2023 and a 75% construction set issued on May 5, 2023.

The project is being funded by the Clio Area School District and is located at 301 Rogers Lodge Drive in Clio, Michigan. No additional details are provided regarding pricing, set-asides, incumbents, or funding sources. The contract term and any renewal options are also not specified in the provided documentation.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

D1

D2

D1

D3

D3 D3

D3

KITCHEN

105A

TOILET

ROOM

CLASSROOM

B100

BOILER

ROOM

HEAD

START

T101

TOILET

ROOM

1 1/4" G

3" CW

D4

D5

D3

BOILER

WATER HEATER

A

6 7 8 9 10

B

C

D

11 12 13 14 15

D6

J.C.

T100

TOILET

ROOM

HEAD

START

C100

CORRIDOR

G

FD

FCO

FCO

CLASSROOM

BOX

OFFICE

CLASSROOM

CLASSROOM

DF

SS

FD

2" CW DN

3/4" HWR DN

1 1/4" HW DN

CW

HWR

HW

D8

PIPE

TRENCH

D8

3 COMPARTMENT SINK/

GREASE INTERCEPTOR

(2)RETURN GRILLES

"Ø

R A

"x

" S

A

Project Title

Key Plan c

Project Designer

Q.M. Review

Approved

Drawing Scale

Project Number

Project Architect / Engineer

Drawn By

Project Administrator

2024 , LLC

Drawing Number

Issued for Issue Date

IDS Drawing Title

1441 west long lake, suite 200 troy, michigan 48098

5211 cascade road SE, suite 300 grand rapids, michigan 49546

248.823.2100 www.ids-michigan.com architecture engineering interiors & technology

I N T E G ETR A D SOLUT SNIO

I N TEG ETRA D SOLU T SNIO

i D s

FOOD SERVICE CONSULTANT

JRA FOOD SERVICE CONSULTANTS, LLC

3113 W. RIVER ROAD

MUSKEGAN, MICHIGAN 49445

616.454.4433 www.jrafoodservicedesign.com

Au tod es k D oc s:/

/C lio

A re a S ch oo l D ist ric t (

)/C

AS

D

Cl io

Ea rly

E lem

-M

.rv t

2/2 /20

9:

:42

A M

T. Vercruysse

J. Schwartz

D. Burgess

M1.1

D. Burgess

C. Haas

M. Koehler

Clio Area School District

1/4" = 1'-0"

23125.1000

301 Rogers Lodge Dr, Clio, MI 48420

First Floor Demolition Plan

Clio Early Elementary Kitchen Renovatiob

LEGEND SYMBOL INDICATOR

NOTE: NOT ALL KEYNOTES MAY BE USED

DEMOLITION

KEYNOTES

D1 CUT HWHS/HWHR PIPING ON BOTH SIDES AND REMOVE HEATING

ELEMENT PIPING ON WALL INCLUDING CONTROLS AND CONTROL

WIRING. PREPARE PIPING FOR NEW CONNECTION.

D2 REMOVE PNEUMATIC THERMOSTAT INCLUDING ALL WIRING AND

ASSOCIATED ACCESSORIES. COORDINATE WALL

REPAIR/PATCHING WITH ARCHITECTURAL TRADES.

D3 REMOVE H&V UNIT, SUPPLY AND RETURN DUCTWORK AND

DIFFUSERS COMPLETE. REMOVE EXTERIOR STRUCTURAL

SUPPORT COMPLETE. COORDINATE WALL PATCH AND REPAIR

WITH ARCHITECTURAL.

D4 REMOVE EXHAUST FAN ABOVE CEILING AND ALL ASSOCIATED

COMPONENTS AND CONTROLS COMPLETE. COORDINATE WALL

PATCH AND REPAIR WITH ARCHITECTURAL.

D5 REMOVE EXHAUST FAN GRILLE AND ALL ASSOCIATED DUCTWORK

COMPLETE.

D6 REMOVE ELECTRIC WATER HEATER, PIPING AND ALL ASSOCIATED

ACCESSORIES COMPLETE.

D7 DISCONNECT 4" SANITARY AND REMOVE AS INDICATED. PREPARE

SANITARY PIPE FOR NEW CONNECTION. COORDINATE SAW

CUTTING WITH ARCHITECTURAL.

D8 REMOVE PLUMBING FIXTURE(S), INCLUDING FLOOR

CLEANOUTS/FLOOR DRAINS, 3 COMPARTMENT SINK, HAND WASH

SINK AND ALL ACCESSORIES COMPLETE.

75% Construction Set 05-05-2023 Quality Management Review 06-30-2023

Bids 02-02-2024

B100

BOILER

ROOM

CLASSROOM

HEAD

START

T101

TOILET

ROOM

105A

TOILET

ROOM

KITCHEN

NEW PIPE CHASE

BY ARCHITECTS

HUV

(IN ATTIC)

(ON ROOF)

EG-A

8"x8"

225 CFM

EG-A

8"x8"

225 CFM

EG-B

6"x6"

100 CFM

8"x8" 12"x12"

"x

(E)BOILER

(E)WATER HEATER

A

8 9 10

B

C

D

11 12

(E)FLUE

DWH

3"Ø EXHAUST FLUE

3"Ø OA INTAKE FLUE

RH

EF

S1

S1

"x

12"x12" UP TO

RELIEF HOOD

Project Title

Key Plan c

Project Designer

Q.M. Review

Approved

Drawing Scale

Project Number

Project Architect / Engineer

Drawn By

Project Administrator

2024 , LLC

Drawing Number

Issued for Issue Date

IDS Drawing Title

1441 west long lake, suite 200 troy, michigan 48098

5211 cascade road SE, suite 300 grand rapids, michigan 49546

248.823.2100 www.ids-michigan.com architecture engineering interiors & technology

I N T E G ETR A D SOLUT SNIO

I N TEG ETRA D SOLU T SNIO

i D s

FOOD SERVICE CONSULTANT

JRA FOOD SERVICE CONSULTANTS, LLC

3113 W. RIVER ROAD

MUSKEGAN, MICHIGAN 49445

616.454.4433 www.jrafoodservicedesign.com

Au tod es k D oc s:/

/C lio

A re a S ch oo l D ist ric t (

)/C

AS

D

Cl io

Ea rly

E lem

-M

.rv t

2/2 /20

9:

:43

A M

T. Vercruysse

J. Schwartz

D. Burgess

M2.1

D. Burgess

C. Haas

M. Koehler

Clio Area School District

1/4" = 1'-0"

23125.1000

301 Rogers Lodge Dr, Clio, MI 48420

First Floor Sheet Metal Plan

Clio Early Elementary Kitchen Renovatiob

LEGEND SYMBOL INDICATOR

NOTE: NOT ALL KEYNOTES MAY BE USED

SHEET METAL

KEYNOTES

S1 TERMINATE PER MANUFACTURER'S RECOMMENDATION.

Owner Review 04-14-2023 75% Construction Set 05-05-2023

3" SAN UP

TO DISPOSAL

A

6 7 8 9 10

B

C

D

11 12 13 14 15

3" SAN UP TO GREASE

INTERCEPTOR

4" SAN UP

TO FLOOR

SINK

4" SAN UP

TO FD

4" SAN UP

TO WC-1

3" SAN UP

TO LAV-1

4" SAN UP

TO FCO

3" SAN UP

TO SINK

3" SAN UP

TO SINK

P8

1 1/2" V UP

4" SAN UP

TO FD

3" SAN UP

TO FD

SAN

SA

N

4"

4" SAN UP

TO FCO

4"

(E)HWR

(E)CW

(E)CW

(E)HW

3/4" 1"

1" 1"

(E)2" CW UP

(E)3/4" HWR UP

(E)1 1/4" HW UP

(E)1 1/2" SAN UP

TO SINK

(E)1 1/2" SAN UP

TO SINK

(E)1 1/2" SAN UP

TO SINK

3" 3"

(E)3" SAN UP

(E)SAN

3"

4"

6"

(E )S

AN

(E)SAN

(E)SAN

3"

(E)3" SAN UP (E)3" SAN UP

(E)3" SAN UP(E)3" SAN UP

(E)3" SAN UP

AVOID (E)PIPE

TRENCH

3" SAN UP

TO FCO

(E)SAN

(E )S

AN

4"

CLASSROOM

B100

BOILER

ROOM

HEAD

START

KITCHEN 105A

TOILET

ROOM

T101

TOILET

ROOM

J.C.

T100

TOILET

ROOM

HEAD

START

CLASSROOM

BOX

OFFICE

CLASSROOM

CLASSROOM

Project Title

Key Plan c

Project Designer

Q.M. Review

Approved

Drawing Scale

Project Number

Project Architect / Engineer

Drawn By

Project Administrator

2024 , LLC

Drawing Number

Issued for Issue Date

IDS Drawing Title

1441 west long lake, suite 200 troy, michigan 48098

5211 cascade road SE, suite 300 grand rapids, michigan 49546

248.823.2100 www.ids-michigan.com architecture engineering interiors & technology

I N T E G ETR A D SOLUT SNIO

I N TEG ETRA D SOLU T SNIO

i D s

FOOD SERVICE CONSULTANT

JRA FOOD SERVICE CONSULTANTS, LLC

3113 W. RIVER ROAD

MUSKEGAN, MICHIGAN 49445

616.454.4433 www.jrafoodservicedesign.com

Au tod es k D oc s:/

/C lio

A re a S ch oo l D ist ric t (

)/C

AS

D

Cl io

Ea rly

E lem

-M

.rv t

2/2 /20

9:

:44

A M

T. Vercruysse

J. Schwartz

D. Burgess

M4.1U

D. Burgess

C. Haas

M. Koehler

Clio Area School District

1/8" = 1'-0"

23125.1000

301 Rogers Lodge Dr, Clio, MI 48420

Underground Plumbing Plan

Clio Early Elementary Kitchen Renovatiob

LEGEND SYMBOL INDICATOR

NOTE: NOT ALL KEYNOTES MAY BE USED

PLUMBING

KEYNOTES

P1 ROUTE (2) 1/2" HOT AND COLD WATER DOWN AND CONNECT TO 3

COMPARTMENT SINK (BY OTHERS) ROUTE 2" SAN FROM 2

COMPARTMENTS TO FLOOR SINK AND TERMINATE WITH AIR GAP.

ROUTE 2" SAN FROM 1 COMPARTMENT DOWN AND CONNECT TO

GREASE INTERCEPTOR. ROUTE 2" VENT UP. REFER TO FOOD

SERVICE EQUIPMENT PLANS FOR ADDITIONAL EQUIPMENT

INFORMATION, PLUMBING ROUGH-IN AND CONNECTION

REQUIREMENTS.

P2 ROUTE 3/4" HOT WATER AND CONNECT TO DISHWASHER (BY

OTHERS). ROUTE 1/2" COLD WATER AND CONNECT TO DRAIN

WATER TEMPERING KIT (BY OTHERS). ROUTE DRAINS FROM

DISHWASHER AND DRAIN TEMPERING KIT TO FLOOR SINK. REFER

TO FOOD SERVICE EQUIPMENT PLANS FOR ADDITIONAL

EQUIPMENT INFORMATION, PLUMBING ROUGH-IN AND

CONNECTION REQUIREMENTS.

P3 ROUTE 1/2" HOT AND COLD WATER DOWN AND CONNECT TO

HAND WASH SINK (BY OTHERS). PROVIDE ASSE 1070 MIXING

VALVE. ROUTE 3" SAN DOWN AND 1 1/2" VENT UP. REFER TO

FOOD SERVICE EQUIPMENT PLANS FOR ADDITIONAL EQUIPMENT

INFORMATION, PLUMBING ROUGH-IN AND CONNECTION

REQUIREMENTS.

P4 ROUTE 1/2" HOT AND COLD WATER AND CONNECT TO LAVATORY

(LAV-1). ROUTE 3" SAN DOWN AND 1 1/2" VENT UP.

P5 ROUTE HWHS/R PIPING RACKED ON WALL IN PRE-FABRICATED

SHEET METAL ENCLOSURE PROVIDED BY MECHANICAL

CONTRACTOR, AND CONNECT TO HORIZONTAL UNIT VENTILATOR.

COLOR SELECTED BY ARCHITECTURAL.

P6 ROUTE 1/2" COLD WATER , 3/4" HOT WATER AND 2" DRAIN AND

CONNECT TO DISPOSAL (BY OTHERS). REFER TO FOOD SERVICE

EQUIPMENT PLANS FOR ADDITIONAL EQUIPMENT INFORMATION,

PLUMBING ROUGH-IN AND CONNECTION REQUIREMENTS.

P7 ROUTE 1" COLD WATER AND CONNECT TO WATER CLOSET (WC-1).

ROUTE 4" SANITARY DOWN AND 2" VENT UP.

P8 CONNECT NEW 4" SANITARY TO EXISTING 4" SANITARY.

P9 MOUNT CONDENSING UNIT ON CONCRETE PAD (BY

ARCHITECTURAL). ROUTE REFRIGERANT PIPING (RS/RL) PIPING

FROM CONDENSING UNIT (ACCU) AND CONNECT TO HORIZONTAL

UNIT VENTILATOR (HUV). RACK ALL PIPING HORIZONTALLY IN

PRE-FABRICATED SHEET METAL ENCLOSURE PROVIDED BY

MECHANICAL CONTRACTOR. COLOR SELECTED BY

ARCHITECTURAL. ROUTE 3/4" COPPER CONDENSATE FROM HUV

THROUGH WALL AND TERMINATE WITH DOWN TURNED ELBOW.

CLASSROOM

B100

BOILER

ROOM

HEAD

START

KITCHEN

105A

TOILET

ROOM

HWHR

HWHS

HWR

HW

CW

(E)WATER HEATER

(E)1 1/4" G (E)3" CW

LAV-1 WC-1

T101

TOILET

ROOM

NEW ARCH SOFFIT FOR

NEW PLUMBING PIPING

HUV

P1 P2

P3

P3

P4

P5

(E)BOILER

CW

(E )G

DWH

HW

(E)G

(E)FCO

FCO

A

6 7 8 9 10

B

C

D

11 12

FS-1

GI

3" VTR

V

V

V

BALANCE VALVE

SET AT 0.5 GPM

HW

R

HWCW V

CAP CW & HW

FOR FUTURE

1 1/2" 1 1/4" 3/4" 1 1/2"

HW CW HW CW

1/2" G DN

1 1/2" CW DN

1 1/2" HW DN

1 1/4"

2" 1 1/4"

1"

P6

HW CW HW CW

CW

HW

2" 1 1/4"

1"

2" 1"

3/4"

2" 1"

1/2"

1 1/2" V DN

V

V

CW

HW

P7

1 1/2"

CW HW

R

3/4"

1 1/2"

DWP

(E)FD

(E)DF

(E)SS

FD

FCO 106

J.C.

T100

TOILET

ROOM

FD

FD

FCO

FD

2" CW DN

3/4" HWR DN

1 1/4" HW DN

(E)CW

(E)HWR

(E)HW

(E)PIPE

TRENCH

FCO

1 1/4" 1 1/4"

RS/RL

RS/RL

3/4" CONDACCU

1P9

Project Title

Key Plan c

Project Designer

Q.M. Review

Approved

Drawing Scale

Project Number

Project Architect / Engineer

Drawn By

Project Administrator

2024 , LLC

Drawing Number

Issued for Issue Date

IDS Drawing Title

1441 west long lake, suite 200 troy, michigan 48098

5211 cascade road SE, suite 300 grand rapids, michigan 49546

248.823.2100 www.ids-michigan.com architecture engineering interiors & technology

I N T E G ETR A D SOLUT SNIO

I N TEG ETRA D SOLU T SNIO

i D s

FOOD SERVICE CONSULTANT

JRA FOOD SERVICE CONSULTANTS, LLC

3113 W. RIVER ROAD

MUSKEGAN, MICHIGAN 49445

616.454.4433 www.jrafoodservicedesign.com

Au tod es k D oc s:/

/C lio

A re a S ch oo l D ist ric t (

)/C

AS

D

Cl io

Ea rly

E lem

-M

.rv t

2/2 /20

9:

:45

A M

T. Vercruysse

J. Schwartz

D. Burgess

M4.1

D. Burgess

C. Haas

M. Koehler

Clio Area School District

1/4" = 1'-0"

23125.1000

301 Rogers Lodge Dr, Clio, MI 48420

First Floor Piping Plan

Clio Early Elementary Kitchen Renovatiob

LEGEND SYMBOL INDICATOR

NOTE: NOT ALL KEYNOTES MAY BE USED

PLUMBING

KEYNOTES

P1 ROUTE (2) 1/2" HOT AND COLD WATER DOWN AND CONNECT TO 3

COMPARTMENT SINK (BY OTHERS) ROUTE 2" SAN FROM 2

COMPARTMENTS TO FLOOR SINK AND TERMINATE WITH AIR GAP.

ROUTE 2" SAN FROM 1 COMPARTMENT DOWN AND CONNECT TO

GREASE INTERCEPTOR. ROUTE 2" VENT UP. REFER TO FOOD

SERVICE EQUIPMENT PLANS FOR ADDITIONAL EQUIPMENT

INFORMATION, PLUMBING ROUGH-IN AND CONNECTION

REQUIREMENTS.

P2 ROUTE 3/4" HOT WATER AND CONNECT TO DISHWASHER (BY

OTHERS). ROUTE 1/2" COLD WATER AND CONNECT TO DRAIN

WATER TEMPERING KIT (BY OTHERS). ROUTE DRAINS FROM

DISHWASHER AND DRAIN TEMPERING KIT TO FLOOR SINK. REFER

TO FOOD SERVICE EQUIPMENT PLANS FOR ADDITIONAL

EQUIPMENT INFORMATION, PLUMBING ROUGH-IN AND

CONNECTION REQUIREMENTS.

P3 ROUTE 1/2" HOT AND COLD WATER DOWN AND CONNECT TO

HAND WASH SINK (BY OTHERS). PROVIDE ASSE 1070 MIXING

VALVE. ROUTE 3" SAN DOWN AND 1 1/2" VENT UP. REFER TO

FOOD SERVICE EQUIPMENT PLANS FOR ADDITIONAL EQUIPMENT

INFORMATION, PLUMBING ROUGH-IN AND CONNECTION

REQUIREMENTS.

P4 ROUTE 1/2" HOT AND COLD WATER AND CONNECT TO LAVATORY

(LAV-1). ROUTE 3" SAN DOWN AND 1 1/2" VENT UP.

P5 ROUTE HWHS/R PIPING RACKED ON WALL IN PRE-FABRICATED

SHEET METAL ENCLOSURE PROVIDED BY MECHANICAL

CONTRACTOR, AND CONNECT TO HORIZONTAL UNIT VENTILATOR.

COLOR SELECTED BY ARCHITECTURAL.

P6 ROUTE 1/2" COLD WATER , 3/4" HOT WATER AND 2" DRAIN AND

CONNECT TO DISPOSAL (BY OTHERS). REFER TO FOOD SERVICE

EQUIPMENT PLANS FOR ADDITIONAL EQUIPMENT INFORMATION,

PLUMBING ROUGH-IN AND CONNECTION REQUIREMENTS.

P7 ROUTE 1" COLD WATER AND CONNECT TO WATER CLOSET (WC-1).

ROUTE 4" SANITARY DOWN AND 2" VENT UP.

P8 CONNECT NEW 4" SANITARY TO EXISTING 4" SANITARY.

P9 MOUNT CONDENSING UNIT ON CONCRETE PAD (BY

ARCHITECTURAL). ROUTE REFRIGERANT PIPING (RS/RL) PIPING

FROM CONDENSING UNIT (ACCU) AND CONNECT TO HORIZONTAL

UNIT VENTILATOR (HUV). RACK ALL PIPING HORIZONTALLY IN

PRE-FABRICATED SHEET METAL ENCLOSURE PROVIDED BY

MECHANICAL CONTRACTOR. COLOR SELECTED BY

ARCHITECTURAL. ROUTE 3/4" COPPER CONDENSATE FROM HUV

THROUGH WALL AND TERMINATE WITH DOWN TURNED ELBOW.

Owner Review 04-14-2023 75% Construction Set 05-05-2023

89.82°

4 1 /2"

R

2 1/2"

SINGLE VANE ELBOW

UP TO 20" IN WIDTH SINGLE VANE DETAIL

90.00°

1 9/16"

SMALL DOUBLE VANE

RUNNER DETAIL

90.00°

4"R

2"R

LARGE DOUBLE VANE DETAIL

8 1/4"

2"R 1"R

90.00°

SMALL DOUBLE VANE DETAIL

SMALL DOUBLE VANE SQUARE

ELBOW UP TO 36" IN WIDTH

1 1/8"

2 1/4"

LARGE DOUBLE VANE SQUARE ELBOW

MORE THAN 36" IN WIDTH LARGE DOUBLE VANE RUNNER DETAIL

SQUARE AND RECTANGULAR ELBOWS - LOW

VELOCITY

NO SCALE

4 1/2"

PACKED GLASS

FIBER

NON-HARDENING

MASTIC

NOTE:

1. COORDINATE WITH ARCH TRADES

FOR FRAME WALL OPENINGS

LARGER THAN 14 INCHES WIDE

OR WHERE METAL STUD MUST BE

CUT TO INSTALL DUCT.

GYPSUM ON METAL

STUF WALL

1" ALL SIDES

DUCT

16 GA. SLEEVE

FASTENED TO

GYPSUM BOARD

DUCT SEAL AT NON-RATED WALLS

NO SCALE

FINISH FLOOR

REFER TO PLANS

FOR SIZE

HW&CW SUPPLIES IN

WALL OR PIPE CHASE

ASSE 1070 TMV

CONCEAL UNDER

COUNTER

CHECK

VALVE (TYP)

ANGLE

STOP (TYP)

½" TW&CW

SUPPLY TO LAV

HAND WASHING SINK/LAV DIAGRAM

NO SCALE

CW

HW

TW

CW

GARBAGE

DISPOSAL

1 1/2" 1 1/4"

TO 3" W

IN WALL

3"

FLOW

CONTROL

GREASE

INTERCEPTOR

2"

FLOOR DRAIN

WITHIN 3FT.

OF SINK

2"(TYP)

2"(TYP)

INDIRECT

WASTE

4"

4"

WASH RINSE SANITIZE

THREE COMPARTMENT SINK WITH

GREASE INTERCEPTOR

NO SCALE

30" MAX

FLOOR

CHECK VALVE

4" HIGH CONCRETE

HOUSEKEEPING

PAD

DIRT LEG

GAS VALVE

UNION TYPICAL

CHARGING VALVE

FLUE WITH DRAFT DIVERTERISOLATION VALVE (TYP)

STRAP ON AQUA-STAT

WITH ELECTRIC TIMER

HOT WATER RECIRC.

PUMP

REFER TO DETAIL

HOSE END

DRAIN

VALVE & CAP

1/2" DRAIN VALVE

BALANCING

VALVE

FLOOR DRAIN

CW

HWR

HW

G

GAS FIRED

WATER

HEATER

GAS FIRED WATER HEATER PIPING DIAGRAM

DI-ELECTRIC

UNION

PRESSURE AND TEMPERATURE

RELIEF VALVE

POTABLE WATER

EXPANSION TANK

SUPPORTED INDEPENDANT

FROM PIPING

NO SCALE

COMBUSTION AIR INTAKE FLUE

UNION (TYP)

COMBINATION FLOW

MEASURING AND

BALANCE DEVICE

(TYP)

MANUAL AIR VENT

CONTROL VALVE

Y-STRAINER WITH

HOSE END

CONNECTION

ISOLATION VALVE (TYP)

HEATING ELEMENT

HW

HS

HW

HR

HOT WATER HORIZONTAL UNIT

VENTILATOR PIPING DIAGRAM

NO SCALE

UNION (TYP)

REDUCER (TYP)

THREADED ROD

CALCIUM SILICATE

INSULATION. SAME

LENGTH AS SADDLE

PIPE: SIZE PER PLAN

GALVANIZED STEEL PIPE

JACKET (SEE NOTE 1)

PIPE SHIELD INCORPORATED

MODEL A 4000 & LOWER

CLEVIS HANGER

SINGLE PIPE SUPPORT (LESS THAN 4")

NO SCALE

NOTES:

1. PROVIDE GALVANIZED SHEET METAL INSULATION JACKET AS FOLLOWS:

PIPE SIZE:

2" TO 4"

LENGTH:

12"

GAUGE:

PIPE PENETRATIONS

NO SCALE

PIPE PENETRATION THRU NON-FIRE RATED WALL

MINERAL WALL INSULATION

TIGHTLY PACKED FOR FULL

DEPTH OF WALL

METAL PIPE SLEEVE

SEAL BOTH SIDES WITH

NON-HARDENING WATER

PROOF CAULK

PIPE

PARTITION

SEAL OR CAULK SLEEVE

THRU FIRE WALL IN A

SMOKE TIGHT MANNER.

PROVIDE U.L. LISTED

FIRE STOPPING SYSTEM

STANDARD WEIGHT STEEL PIPE

SLEEVE OF SIZE TO PASS PIPE

AND INSULATION

FINISHED EXCUTCHEON PLATE

FLUSH AGAINST WALL AND OF

SIZE TO COMPLETELY COVER

OPENING

FINISHED WALL SURFACE

PIPE THRU FIRE RATED WALL OR FLOOR

SEALING AND

ANCHORING COLLAR

SEAL WATERTIGHT WITH

MASTIC OR ASPHALT

CENTER PIPE

IN SLEEVE

CONTINUOUS WELD

STANDARD WEIGHT STEEL PIPE

SLEEVE INSTALLED DURING

WALL CONSTRUCTION

COAT EXTERIOR SURFACE

WITH TAR COMPOUND

FINISHED WALL SURFACE

SEAL SLEEVE WITH TIGHTLY PACKED

FIBERGLASS OR 'LINK-SEAL'

PIPE THRU EXTERIOR WALL

1/4"

Project Title

Key Plan c

Project Designer

Q.M. Review

Approved

Drawing Scale

Project Number

Project Architect / Engineer

Drawn By

Project Administrator

2024 , LLC

Drawing Number

Issued for Issue Date

IDS Drawing Title

1441 west long lake, suite 200 troy, michigan 48098

5211 cascade road SE, suite 300 grand rapids, michigan 49546

248.823.2100 www.ids-michigan.com architecture engineering interiors & technology

I N T E G ETR A D SOLUT SNIO

I N TEG ETRA D SOLU T SNIO

i D s

FOOD SERVICE CONSULTANT

JRA FOOD SERVICE CONSULTANTS, LLC

3113 W. RIVER ROAD

MUSKEGAN, MICHIGAN 49445

616.454.4433 www.jrafoodservicedesign.com

Au tod es k D oc s:/

/C lio

A re a S ch oo l D ist ric t (

)/C

AS

D

Cl io

Ea rly

E lem

-M

.rv t

2/2 /20

9:

:46

A M

T. Vercruysse

J. Schwartz

D. Burgess

M6.1

D. Burgess

C. Haas

M. Koehler

Clio Area School District

As Noted

23125.1000

301 Rogers Lodge Dr, Clio, MI 48420

Details

Clio Early Elementary Kitchen Renovatiob

75% Construction Set 05-05-2023

Project Title

Key Plan c

Project Designer

Q.M. Review

Approved

Drawing Scale

Project Number

Project Architect / Engineer

Drawn By

Project Administrator

2024 , LLC

Drawing Number

Issued for Issue Date

IDS Drawing Title

1441 west long lake, suite 200 troy, michigan 48098

5211 cascade road SE, suite 300 grand rapids, michigan 49546

248.823.2100 www.ids-michigan.com architecture engineering interiors & technology

I N T E G ETR A D SOLUT SNIO

I N TEG ETRA D SOLU T SNIO

i D s

FOOD SERVICE CONSULTANT

JRA FOOD SERVICE CONSULTANTS, LLC

3113 W. RIVER ROAD

MUSKEGAN, MICHIGAN 49445

616.454.4433 www.jrafoodservicedesign.com

Au tod es k D oc s:/

/C lio

A re a S ch oo l D ist ric t (

)/C

AS

D

Cl io

Ea rly

E lem

-M

.rv t

2/2 /20

9:

:47

A M

T. Vercruysse

J. Schwartz

D. Burgess

M7.1

D. Burgess

C. Haas

M. Koehler

Clio Area School District

No Scale

23125.1000

301 Rogers Lodge Dr, Clio, MI 48420

Schedules

Clio Early Elementary Kitchen Renovatiob

1. PROVIDE FACTORY MOUNTED AND WIRED DISCONNECT.

NOTES:

HUV-1 1/4 1,500 450 73.9 3.8 46.0 93.9 140/100 5.0 2 80/67 57/56.1 28.0 39.8 98 21.83 30.26 1x10x36

MERV 8 2 3.4 15 115/1/60 ZFV1500 SEE SCHEDULE 2" SUB BASE

HP CFM MBH GPM EAT

(°F)

LAT

(°F)

EWT/LWT

(°F)

MAX PD

(FT. HD)

MIN

ROWS

EAT

DB/WB

(°F)

LAT

DB/WB

(°F)

SENS.

MBH

TOTAL

MBH WIDTH DEPTH HEIGHT TYPE QUANTITY MCA MOP V/PH/Hz

MARK

SUPPLY FAN

OUTSIDE

AIR

(CFM)

HEATING COIL (HOT WATER) DX COOLING (95°F AMBIENT) MAX. ENCLOSURE DIM (IN) FILTER ELECTRICAL

"AIREDALE"

MODEL No.

REMOTE

CONDENSING

UNIT

REMARKS

HORIZONTAL UNIT VENTILATOR SCHEDULE

2. PROVIDE EXPANSION TANK, "LOCHINVAR" MODEL No. LTCPA 20, OR EQUAL.

1. PROVIDE ONE COMMON CONDENSATE NEUTRALIZATON TANK PER WATER HEATING SYSTEM.

NOTES:

DWH-1 BUILDING 4-14 150 96 5:1 90 40 140 175 115/1/60 SWA150N

MIN-MAX

PRESS

(IN.WC.)

INPUT

(MBH)

EFF.

MOD.

RATIO

VOLUME

(GAL)

EWT

(°F)

LWT

(°F)

GPH

100°F RISE V/P/Hz

MARK SERVICE

NATURAL GAS DATA WATER ELECTRICAL

"LOCHINVAR"

MODEL No. REMARKS

CONDENSING DOMESTIC HOT WATER HEATER SCHEDULE

1. PROVIDE ALL FANS WITH FACTORY MOUNTED AND WIRED DISCONNECT.

NOTES:

EF-1 ATTIC KITCHEN AND TOILET ROOM 550 550 0.4 INLINE DIRECT 1,531 1/4 0.09 1,800 115/1/60 79 77 72 64 58 49 40 38 SQ-95-VG

HZ HZ HZ HZ HZ HZ HZ HZ

TYPE DRIVE FAN

RPM HP BHP RPM

63 125 250 500 1K 2K 4K 8KMARK LOCATION AREA SERVED

DESIGN

AIRFLOW

(CFM)

INITIAL

CONN.

AIRFLOW

(CFM)

EXTERNAL

STATIC

PRESSURE

(IN. WG.)

FAN DATA MOTOR DATA

ELECTRICAL

V/PH/HZ

INLET SOUND POWER LEVEL

"GREENHECK"

MODEL No. REMARKS

FAN SCHEDULE

3. SG-B FRONT BLADES PARALLEL TO SHORT DIMENSION.

2. ALL WALL AND DUCT MOUNTED GRILLES SHALL HAVE COUNTER-SUNK SCREWS.

1. COORDINATE MOUNTING FRAMES WITH REFLECTED CEILING PLANS.

NOTES:

EG-B PERFORATED NOTE 1 12"x12" WHITE NONE STEEL PDDR

EG-A PERFORATED NOTE 1 24"x24" WHITE NONE STEEL PDDR

MARK CORE STYLE BORDER

FRAME TYPE MODULE SIZE FINISH ACCESSORY CONSTRUCTION "PRICE"

MODEL No. REMARKS

GRILLE, REGISTER AND DIFFUSER SCHEDULE

1. PROVIDE WITH ALUMINUM BIRDSCREEN AND INSECT SCREEN.

NOTES:

RH-1 RELIEF 550 0.073 26 27 26 12 12 18 FGR-12x12

WIDTH LENGTH HEIGHT WIDTH LENGTH

MARK SERVICE AIRFLOW

(CFM)

AIR STATIC

PRESSURE (IN

WG)

HOOD DIMENSIONS (IN) THROAT DIM. (IN) CURB

HEIGHT

(IN)

"GREENHECK"

MODEL No. REMARKS

GRAVITY HOOD SCHEDULE

GI-1 KITCHEN 3 / 3 25 21 50 32.25 x19.875 x 17 Z1170-600

FLOW

(GPM)

WATER

(GAL.)

GREASE

(LBS.)

MARK SERVICE

INLET/

OUTLET

(IN.)

CAPACITY

DIMENSIONS

L x W x H

(INCHES)

"ZURN"

MODEL No. REMARKS

GREASE INTERCEPTOR SCHEDULE

DWP-1 BOILER ROOM DOMESTIC HOT WATER INLINE 2 20 270 Watts 4600 115 1 NBF-36

GPM FT. HEAD HP RPM VOLTS PHASE

MARK LOCATION SYSTEM SERVED TYPE

PUMP MOTOR "BELL & GOSSETT"

MODEL No. REMARKS

PUMP SCHEDULE

1. REFRIGERANT SUCTION PIPING SHALL BE INSULATED USING 1" THICK EXPANDED FOAM INSULATION.

NOTES:

CU-3.0 COOLING ONLY R410A 3.0 19.6 30 240/1/60 29.25x29.25x30 145 YCE36

MCA MOCP V/PH/HZ

DIMENSIONS

L x W x H

(IN.)

WEIGHT

(LBS)

MARK SYSTEM TYPE REFRIGERANT CAPACITY

TONS

ELECTRICAL PHYSICAL

"YORK"

MODEL No. REMARKS

CONDENSING UNIT SCHEDULE

75% Construction Set 05-05-2023

SUPPLY AIR

TO SINGLE ZONE

RETURN

AIR

OUTSIDE

AIR

F I L T E R

DPT

SUPPLY

FAN

HWH HEATING

COIL

HW

HS

HW

HR

MTR

CTRL

THERMOSTAT INCLUDING:

- USER STPT ADJ

- TEMPERATURE SENSOR

- CARBON DIOXIDE SENSOR

- OCCUPIED MODE BUTTON

BY MFR

PACKAGED

UNIT

CONTROL

PANEL

BACnet MSTP

HORIZONTAL UNIT VENTILATOR CONTROL DIAGRAM

UNOCCUPIED MODE

1. THE UNIT SHALL DEACTIVATE AND CLOSE THE OUTSIDE AIR DAMPER.

2. THE HEATING COIL CONTROL VALVE SHALL MODULATE TO MAINTAIN MINIMUM CABINET

TEMPERATURE FOR FREEZE PROTECTION.

3. THE UNIT SHALL CYCLE ON AND SHALL CONTROL TO MAINTAIN THE UNOCCUPIED SPACE

TEMPERATURE RANGE (60°F TO 80°F, ADJ). DURING UNOCCUPIED MODE OPERATION, THE

OUTSIDE AIR DAMPER SHALL REMAIN CLOSED.

4. DURING UNOCCUPIED MODE, IF THE THERMOSTAT OCCUPIED MODE BUTTON IS PRESSED,

THE UNIT SHALL OPERATE PER THE OCCUPIED MODE SEQUENCE FOR 2 HOURS (ADJ).

SAFETIES & INTERLOCKS

1. IF ANY OF THE FOLLOWING SAFETY DEVICES ARE ACTIVATED, THE UNIT SHALL DEACTIVATE, THE OUTSIDE AIR DAMPERS SHALL CLOSE, AND THE RETURN AIR DAMPER SHALL OPEN:

A. FREEZESTAT

N.C.

N.O.

NOTES

1. HORIZONTAL UNIT VENTILATOR (HUV) TO BE PROVIDED WITH PACKAGED DDC CONTROLS BY

THE UNIT MANUFACTURER. MECHANICAL SYSTEMS CONTROLS CONTRACTOR (MSCC) TO

FIELD INSTALL, WIRE, AND TERMINATE IN THE PACKAGED UNIT DDC CONTROLLER, ANY

APPLICABLE SENSORS OR DEVICES AS NECESSARY PER THE UNIT MANUFACTURER'S

REQUIREMENTS FOR A COMPLETE SYSTEM.

SEQUENCE OF OPERATION

MODES OF OPERATION

1. THE UNIT SHALL OPERATE IN EITHER OCCUPIED OR UNOCCUPIED MODE.

2. THE OPERATING MODE OF THE UNIT SHALL BE AUTOMATICALLY CYCLED BETWEEN

OCCUPIED AND UNOCCUPIED MODE BASED ON THE SET UNIT TIME SCHEDULE.

OCCUPIED MODE

1. THE SUPPLY FAN SHALL START.

2. THE MIXED AIR DAMPERS SHALL OPEN TO FIXED OUTSIDE AIR POSITION. THIS POSITION

SHALL BE SET IN COORDINATION WITH THE TEST AND BALANCE CONTRACTOR.

3. THE HEATING COIL, MIXED AIR DAMPERS, AND COOLING COIL SHALL CONTROL IN SERIES TO

MAINTAIN THE THERMOSTAT TEMPERATURE SETPOINT, INCLUDING ECONOMIZER

OPERATION.

4. NORMAL OUTSIDE AIR DAMPER MODULATION SHALL BE LIMITED TO MAINTAIN THE SPACE

CARBOC DIOXIDE HIGH LIMIT SETPOINT (1,000 PPM, ADJ).

DX COOLING

EVAP COIL

CLG

CTRL

OUTDOOR

CONDENSING

UNIT

OWNER IP NETWORK

GATEWAY

EXISTING OWNER TRIDIUM/NIAGARA 4 BAS

OPERATOR INTERFACE SYSTEM SERVER

TO ADDITIONAL

MECHANICAL EQUIPMENT

CONTROLLERS

SITE BAS NETWORK

GATEWAY/

CONTROLLER(S)

BACnet

MECH EQUIP

CONTROLLER

MECH EQUIP

CONTROLLER

GATEWAY

ADDITIONAL/FUTURE

SITE GATEWAY(S)/

CONTROLLER(S)

TO ADDITIONAL

EQUIPMENT

CONTROLLERS

EQUIPMENT

CONTROLLER

EQUIPMENT

CONTROLLER

EQUIPMENT

CONTROLLER

BUILDING AUTOMATION SYSTEM NETWORK RISER DIAGRAM

NOTES

1. THE MECHANICAL SYSTEMS CONTROLS CONTRACTOR (MSCC) SHALL PROVIDE A NEW BUILDING AUTOMATION SYSTEM (BAS) CONTROLLER/GATEWAY

DEVICE OR DEVICES, POWER SUPPLIES, AND NEMA 1 ENCLOSURES AS NECESSARY TO INTEGRATE ALL FIELD DEVICES AND DEVICE NETWORKS TO THE

OWNER CENTRAL BAS OPERATOR INTERFACE SYSTEM (OIS) SERVER.

2. MSCC SHALL PROVIDE ETHERNET IP DATA CONNECTION(S) AND LOCATE DEVICE(S) AS NECESSARY IN COORDINATION WITH THE

ELECTRICAL/TECHNOLOGY CONTRACTOR AND THE OWNER.

T 120V

120V/24V

TRANSFORMER

(TYP)

T 120V

MECH EQUIP

CONTROLLER

CONTROL

PANEL

DOMESTIC

WATER

HEATER

DWH-1

GATEWAY BACnet MSTP

24V

BY MFR

EMERGENCY

OFF

NOTES

1. HEATERS TO BE PROVIDED WITH PACKAGED CONTROLS. MECHANICAL

SYSTEMS CONTROLS CONTRACTOR (MSCC) TO FIELD INSTALL, WIRE, AND

TERMINATE IN THE PACKAGED CONTROLLER ANY APPLICABLE SENSORS OR

DEVICES AS NECESSARY PER THE UNIT MANUFACTURERS REQUIREMENTS

FOR A COMPLETE SYSTEM.

2. MSCC SHALL FIELD INSTALL AND WIRE NETWORKING DEVICES AS NECESSARY

TO CONNECT AND INTEGRATE UNITS TO THE BUILDING AUTOMATION SYSTEM.

DOMESTIC HOT WATER SYSTEM

CONTROL DIAGRAM

TYPICAL SINGLE PHASE

EXHAUST FAN WIRING DETAIL

L1 NSEE EQUIP. SCHEDULE FOR VOLTAGE

MTR

OL

ON OFF DDC

DAMPER

ACTUATOR W/

ENDSWITCH

EXHAUST

FAN

EXHAUST

AIR FROM

SPACE

SEQUENCE OF OPERATION

1. THE EF SHALL BE SET TO ACTIVATE AND DEACTIVATE ACCORDING TO THE SET

HUV OPERATION TIME SCHEDULE FOR OCCUPIED AND UNOCCUPIED TIME

PERIODS.

EXHAUST FAN CONTROL DIAGRAM

DAMPER & ACTUATOR W/

ENDSWITCH BY MSCC

RELIEF HOOD

D-1 N.C.

Project Title

Key Plan c

Project Designer

Q.M. Review

Approved

Drawing Scale

Project Number

Project Architect / Engineer

Drawn By

Project Administrator

2024 , LLC

Drawing Number

Issued for Issue Date

IDS Drawing Title

As Noted

1441 west long lake, suite 200 troy, michigan 48098

5211 cascade road SE, suite 300 grand rapids, michigan 49546

248.823.2100 www.ids-michigan.com architecture engineering interiors & technology

I N T E G ETR A D SOLUT SNIO

I N TEG ETRA D SOLU T SNIO

i D s

FOOD SERVICE CONSULTANT

JRA FOOD SERVICE CONSULTANTS, LLC

3113 W. RIVER ROAD

MUSKEGAN, MICHIGAN 49445

616.454.4433 www.jrafoodservicedesign.com

Au tod es k D oc s:/

/C lio

A re a S ch oo l D ist ric t (

)/C

AS

D

Cl io

Ea rly

E lem

-M

.rv t

2/2 /20

9:

:48

A M

T. Vercruysse

J. Schwartz

J. Gutzeit

M8.1

J. Gutzeit

C. Haas

M. Koehler

Clio Area School District

23125.1000

301 Rogers Lodge Dr, Clio, MI 48420

Mechanical Systems Controls

Clio Early Elementary Kitchen Renovatiob

75% Construction Set 05-05-2023

HEAD START

CORRIDOR

CLASSROOM CLASSROOMBOILER ROOM

RESTROOM

DISHWASHING

DRY STORAGEPREPEXISTING WINDOW TO BE FILLED

- NIKEC

NORTH

Key Plan c

Project Designer

Q.M. Review

Approved

Drawing Scale

Project Number

Project Architect / Engineer

Drawn By

Project Administrator

2021 , LLC

Drawing Number

Issued for Issue Date

IDS Drawing Title

SCALE 1/4" = 1'-0"

1441 west long lake, suite 200 troy, michigan 48098

5211 cascade road SE, suite 300 grand rapids, michigan 49546

248.823.2100 www.ids-michigan.com architecture engineering interiors & technology

I N T E G ETR A D SOLU T SNIO

I N TEG ETR A D SOLU T SNIO

i D s

FOOD SERVICE CONSULTANT

JRA FOOD SERVICE CONSULTANTS, LLC

401 HALL STREET SW, SUITE 185H

GRAND RAPIDS, MICHIGAN 49503

616.454.4433 www.jrafoodservicedesign.com

Clio Area School District

301 Rogers Lodge Dr, Clio, MI 48420

Clio Early Elementary Kitchen Renovation

A. Forzley

FSE - 1

FOOD SERVICE

EQUIPMENT

FLOOR PLAN

C. Payne

J. Riemenschneider

Designer

C. Hass

J. Gondek

23125-1000

AND STORED OR DISCARDED

FOR CONSTRUCTION PURPOSES.

AS DIRECTED BY OWNER.

ANY EXISTING EQUIPMENT AS REQUIRED

EQUIPMENT NOT BEING REUSED TO BE DISCONNECTED

RELOCATED AS PER PLANS AND SPECIFICATIONS.

BE DISCONNECTED AND

EQUIPMENT DESIGNATED AS RELOCATED SHALL5.

4.

WHERE APPLICABLE.

VERIFY ROUGHIN REQUIREMENTS FOR

REUSE EXISTING ROUGHINS

FUTURE, PURVEYOR SUPPLIED, OWNERS RELOCATED

EQUIPMENT, OWNER SUPPLIED EQUIPMENT, ETC.

DISCONNECT, REMOVE, STORE & RECONNECT

2.

3.

NOTE:

1.

EXISTING DOOR TO BE FILLED

- NIKEC

GREASE TRAP

UNIT VENTILATOR

ELECTRICAL PANEL

CLASSROOM

30"

34"

10"

14 GA. 304 STAINLESS STEEL TOP AS PER PLAN

20" X 20" X 5" ROLLER BEARING

STAINLESS STEEL LEGS & GUSSETS

5" LOCKING CASTERS

STAINLESS STEEL DRAWER

18 GA. 304 STAINLESS STEEL UNDERSHELF

BACKSPLASH WITH ENCLOSED BACK

6"

10"

2"

14 GA. 304 STAINLESS STEEL TOP AS PER PLAN

20" X 20" X 5" ROLLER BEARING

STAINLESS STEEL LEGS & GUSSETS

STAINLESS STEEL BULLET FEET

STAINLESS STEEL DRAWER

18 GA. 304 STAINLESS STEEL UNDERSHELF

2'-10"

12" S.S. WALL SHELF

BACKSPLASH & WALL CLIP

2'-0"

2'-6"

BOARD BELOW

BEARING DRAWER & CUTTING

STAINLESS STEEL ROLLER

4'-0"

2'-2"

2'-2"

STAINLESS STEEL CROSS BRACING

5" LOCKING CASTERS

STAINLESS STEEL UNDERSHELF

14 GA. 304 STAINLESS

12" STAINLESS STEEL OVERSHELF & UPRIGHTS

STEEL TOP AS PER PLAN

STAINLESS STEEL UTENSIL RACK & HOOKS

SCALE 1/4" = 1'-0" ELEVATION

CEILING

WALL

HAND SINK

WALLMICROWAVE OVEN

SCALE 1/4" = 1'-0" ELEVATION

CEILING

PORTABLE TABLE COOKS TABLE

CAN OPENER

UTENSIL RACK

OVERSHELF

W/ SIDE SPLASHES

TRASH BIN

- BY OWNER

HAND SINK

W/ SIDE SPLASHES

TRASH BIN

- BY OWNER

REFRIGERATOR COOK & HOLD

HOT FOOD CABINET

OVEN

WORKTABLE

& SHELF

14 GA. 304 S.S. SINK

WASTE VALVE WITH CONNECTED

OVERFLOW AND SUPPORT CLIP

TYPICAL 12" FLOOR SINK

WITH REMOVABLE

INDIRECT WASTE PIPING

S.S. LEGS, FEET & CROSSRAILS

8" 180° ROLLED RIM

& HALF GRATE

SEDIMENT BUCKET

14"

WITH AIR GAP

AND DRAINBOARDS

1'-6"

26.5"

BACKSPLASH & WALL CLIP

WIRE OVERSHELF BY FSEC

1.5±"2"

24X54 24X54

X3

24X48 24X48

02-02-2024 ISSUED FOR BIDDING

c 2024

Key Plan c

Project Designer

Q.M. Review

Approved

Drawing Scale

Project Number

Project Architect / Engineer

Drawn By

Project Administrator

2021 , LLC

Drawing Number

Issued for Issue Date

IDS Drawing Title

SCALE 1/4" = 1'-0"

1441 west long lake, suite 200 troy, michigan 48098

5211 cascade road SE, suite 300 grand rapids, michigan 49546

248.823.2100 www.ids-michigan.com architecture engineering interiors & technology

I N T E G ETR A D SOLU T SNIO

I N TEG ETR A D SOLU T SNIO

i D s

FOOD SERVICE CONSULTANT

JRA FOOD SERVICE CONSULTANTS, LLC

401 HALL STREET SW, SUITE 185H

GRAND RAPIDS, MICHIGAN 49503

616.454.4433 www.jrafoodservicedesign.com

Clio Area School District

301 Rogers Lodge Dr, Clio, MI 48420

Clio Early Elementary Kitchen Renovation

A. Forzley

FSE - 2

FOOD SERVICE

ELECTRICAL

FLOOR PLAN

C. Payne

J. Riemenschneider

Designer

C. Hass

J. Gondek

23125-1000

AND STORED OR DISCARDED

FOR CONSTRUCTION PURPOSES.

AS DIRECTED BY OWNER.

ANY EXISTING EQUIPMENT AS REQUIRED

EQUIPMENT NOT BEING REUSED TO BE DISCONNECTED

RELOCATED AS PER PLANS AND SPECIFICATIONS.

BE DISCONNECTED AND

EQUIPMENT DESIGNATED AS RELOCATED SHALL5.

4.

WHERE APPLICABLE.

VERIFY ROUGHIN REQUIREMENTS FOR

REUSE EXISTING ROUGHINS

FUTURE, PURVEYOR SUPPLIED, OWNERS RELOCATED

EQUIPMENT, OWNER SUPPLIED EQUIPMENT, ETC.

DISCONNECT, REMOVE, STORE & RECONNECT

2.

3.

FLOOR DRAIN - 3" MINIMUM DRAIN - MINIMUM PITCH

FUNNEL FLOOR DRAIN FOR IW - 3" MINIMUM DRAIN

FLOOR SINK FOR IW - 12" SQ. - HALF GRATE - 3" MIN.

NATURAL GAS - 7" W.C. OR LP GAS - 11" W.C. - VIF

BEVERAGE CONDUIT WITH 18" SWEEP ENDS BY TRADES - VIF

EXHAUST VENT CONNECTION

CUBIC FEET MINUTE

MAKE UP AIR DUCT CONNECTION

STATIC PRESSURE

CFM

BC

SP

EVC

MUA

COLD WATER - 25 PSI

WASTE DRAIN - DIRECT CONNECTION

HOT WATER - 25 PSI - 115 DEGREES

FFD

FS

FFD

FL SK

FD

W

FD

VERIFY IN FIELD

VOLTS

HW

CW

G

V

VIF

WATERTIGHT FLUSH FLOOR DUPLEX - 20 AMP - GFIC

W.T. FLUSH FLOOR POWER/COMMUNICATIONS RECEPTACLE

INDIRECT/AIR GAPPED WASTE TO FL DR OR FL SK

BRANCH TO CONNECTION BY TRADES

DROP FROM ABOVE

ABOVE FINISHED FLOOR

UNLESS OTHERWISE NOTED

GENERAL PURPOSE

HP HORSEPOWER

KILOWATT

PHASE

UON

PH

KW

IW

GP

DFA

BTC

AFF

SPECIAL RECEPTACLE - 120 VOLT

SPECIAL RECEPTACLE - 208/240 VOLT

AMPS

JUNCTION BOX

LIGHT FIXTURE

JB JB

A

LT

SR

SR

TFT TEMPERED FLOOR TROUGH

120 V - 20 AMP SIMPLEX OUTLET - GFIC VERTICALLY MOUNTED

120 V - 20 AMP DUPLEX RECEPTACLE - GFIC VERTICALLY MOUNTED

120 VOLT - 30 AMP QUAD OUTLET

DATA CONNECTION

NIKEC NOT IN KITCHEN EQUIPMENT CONTRACT

21. VERIFY VENTILATION DATA WITH HOOD MFG. SHOP DRAWINGS.

FOR HEALTH DEPARTMENT AND RETURNED TO THE SITE.

16. EQUIPMENT NOT BEING RE-USED SHALL BE DISCARDED.

OWNER SUPPLIED, RELOCATED, OR EXISTING EQUIPMENT WITH ALL TRADES

13. COORDINATE ROUGHIN REQUIREMENTS FOR

TERMINATION POINT TO ALLOW WIRING/PIPING TO FIXTURE.

4. FURNISH AND INSTALL ALL ACCESSORIES (FAUCETS, SWITCHES,

3. SHALL MAKE ALL FINAL CONNECTIONS BETWEEN EQUIPMENT AND ROUGH-IN POINT,

8. PROVIDE ACCESS HOLES IN EQUIPMENT FOR UTILITIES, PIPING, POS,

7. PROVIDE CHASES/REWORK OF WALLS, FLOORS, CEILINGS FOR UTILITIES,

POSSIBLE TO KEEP FLOORS AS CLEAN AS POSSIBLE. ROUGH-INS ARE SHOWN AT

6. ALL "ROUGH-INS" SHOULD BE "UP-WITHIN" AND THEN "OUT-OF" WALLS WHERE

ROUGH-IN DRAWINGS AND SHOP DRAWINGS FOR ACTUAL REQUIREMENTS.

2. DO NOT ROUGH-IN FROM THIS DRAWING. REFER TO F.S.E.C. DIMENSIONED

AND FURNISH ALL WIRING, SWITCHES, CONTROLS, SERVICE VALVES, PIPING, ETC AS REQUIRED.

5. SLOPES TO FD'S SHOULD BE HELD TO A MINIMUM DIMENSION.

1. KITCHEN EQUIPMENT SHALL BE DELIVERED AND ERECTED

PROVIDE ROOM VENTILATION (A/C RECOMMENED) AS REQUIRED

9. PROVIDE VENTILATION, STRUCTURAL SUPPORT, CEILING WORK,

10. EXHAUST HOOD SHALL BE USED FOR VENTILATION OF COOKING EQUIPMENT ONLY.

12. REVIEW ALL ROUGHINS AND SHOP DRAWINGS FROM F.S.E.C. AND

11. PROVIDE ADEQUATE VENTILATION FOR REFRIGERATION

COMPRESSORS, WHETHER AIR OR WATER COOLED.

14. REUSE EXISTING ROUGHINS IF APPLICABLE

ADVISE PRIOR TO ROUGHING IN IF ANY CHANGES ARE REQUIRED.

15. EQUIPMENT NOT BEING REUSED TO BE DISCONNECTED.

19. EQUIPMENT DESIGNATED AS RELOCATED SHALL BE REMOVED FROM SITE, CLEANED, MADE READY

18. EQUIPMENT DESIGNATED AS RELOCATED SHALL BE DISCONNECTED FROM UTILITIES.

17. IF OWNER REQUESTS EXISTING EQUIPMENT BE SALVAGED TURN OVER TO OWNER.

20. EQUIPMENT DESIGNATED AS RELOCATED SHALL BE RE-CONNECTED.

ROOF PENETRATIONS AND FIRE PROOFING AS REQUIRED.

FLOOR GRATES, WALKINS, DUCTS, ETC.

BEVERAGE LINES, ETC.

CORDS, VALVES, GAS HOSES, ETC.).

FURNISH DRAIN WATER TEMPERING KIT(S).

02-02-2024 ISSUED FOR BIDDING

Key Plan c

Project Designer

Q.M. Review

Approved

Drawing Scale

Project Number

Project Architect / Engineer

Drawn By

Project Administrator

2021 , LLC

Drawing Number

Issued for Issue Date

IDS Drawing Title

SCALE 1/4" = 1'-0"

1441 west long lake, suite 200 troy, michigan 48098

5211 cascade road SE, suite 300 grand rapids, michigan 49546

248.823.2100 www.ids-michigan.com architecture engineering interiors & technology

I N T E G ETR A D SOLU T SNIO

I N TEG ETR A D SOLU T SNIO

i D s

FOOD SERVICE CONSULTANT

JRA FOOD SERVICE CONSULTANTS, LLC

401 HALL STREET SW, SUITE 185H

GRAND RAPIDS, MICHIGAN 49503

616.454.4433 www.jrafoodservicedesign.com

Clio Area School District

301 Rogers Lodge Dr, Clio, MI 48420

Clio Early Elementary Kitchen Renovation

A. Forzley

FSE - 3

FOOD SERVICE

PLUMBING

FLOOR PLAN

C. Payne

J. Riemenschneider

Designer

C. Hass

J. Gondek

23125-1000

AND STORED OR DISCARDED

FOR CONSTRUCTION PURPOSES.

AS DIRECTED BY OWNER.

ANY EXISTING EQUIPMENT AS REQUIRED

EQUIPMENT NOT BEING REUSED TO BE DISCONNECTED

RELOCATED AS PER PLANS AND SPECIFICATIONS.

BE DISCONNECTED AND

EQUIPMENT DESIGNATED AS RELOCATED SHALL5.

4.

WHERE APPLICABLE.

VERIFY ROUGHIN REQUIREMENTS FOR

REUSE EXISTING ROUGHINS

FUTURE, PURVEYOR SUPPLIED, OWNERS RELOCATED

EQUIPMENT, OWNER SUPPLIED EQUIPMENT, ETC.

DISCONNECT, REMOVE, STORE & RECONNECT

2.

3.

S.S. BRACKET

FINAL CONNECTION

BY FSEC

CONTROL PANEL

WITH DISCONNECT

S.O. VALVE

CW CONNECTION AND

DRAINBOARD

CONE

DRAIN PIPING

PRE-RINSE BY FSEC

DISPOSER

PIPING

SOLENOID

WIRING

SYPHON BREAKER

BY FSEC

FLOOR DRAIN - 3" MINIMUM DRAIN - MINIMUM PITCH

FUNNEL FLOOR DRAIN FOR IW - 3" MINIMUM DRAIN

FLOOR SINK FOR IW - 12" SQ. - HALF GRATE - 3" MIN.

NATURAL GAS - 7" W.C. OR LP GAS - 11" W.C. - VIF

BEVERAGE CONDUIT WITH 18" SWEEP ENDS BY TRADES - VIF

EXHAUST VENT CONNECTION

CUBIC FEET MINUTE

MAKE UP AIR DUCT CONNECTION

STATIC PRESSURE

CFM

BC

SP

EVC

MUA

COLD WATER - 25 PSI

WASTE DRAIN - DIRECT CONNECTION

HOT WATER - 25 PSI - 115 DEGREES

FFD

FS

FFD

FL SK

FD

W

FD

VERIFY IN FIELD

VOLTS

HW

CW

G

V

VIF

WATERTIGHT FLUSH FLOOR DUPLEX - 20 AMP - GFIC

W.T. FLUSH FLOOR POWER/COMMUNICATIONS RECEPTACLE

INDIRECT/AIR GAPPED WASTE TO FL DR OR FL SK

BRANCH TO CONNECTION BY TRADES

DROP FROM ABOVE

ABOVE FINISHED FLOOR

UNLESS OTHERWISE NOTED

GENERAL PURPOSE

HP HORSEPOWER

KILOWATT

PHASE

UON

PH

KW

IW

GP

DFA

BTC

AFF

SPECIAL RECEPTACLE - 120 VOLT

SPECIAL RECEPTACLE - 208/240 VOLT

AMPS

JUNCTION BOX

LIGHT FIXTURE

JB JB

A

LT

SR

SR

TFT TEMPERED FLOOR TROUGH

120 V - 20 AMP SIMPLEX OUTLET - GFIC VERTICALLY MOUNTED

120 V - 20 AMP DUPLEX RECEPTACLE - GFIC VERTICALLY MOUNTED

120 VOLT - 30 AMP QUAD OUTLET

DATA CONNECTION

NIKEC NOT IN KITCHEN EQUIPMENT CONTRACT

21. VERIFY VENTILATION DATA WITH HOOD MFG. SHOP DRAWINGS.

FOR HEALTH DEPARTMENT AND RETURNED TO THE SITE.

16. EQUIPMENT NOT BEING RE-USED SHALL BE DISCARDED.

OWNER SUPPLIED, RELOCATED, OR EXISTING EQUIPMENT WITH ALL TRADES

13. COORDINATE ROUGHIN REQUIREMENTS FOR

TERMINATION POINT TO ALLOW WIRING/PIPING TO FIXTURE.

4. FURNISH AND INSTALL ALL ACCESSORIES (FAUCETS, SWITCHES,

3. SHALL MAKE ALL FINAL CONNECTIONS BETWEEN EQUIPMENT AND ROUGH-IN POINT,

8. PROVIDE ACCESS HOLES IN EQUIPMENT FOR UTILITIES, PIPING, POS,

7. PROVIDE CHASES/REWORK OF WALLS, FLOORS, CEILINGS FOR UTILITIES,

POSSIBLE TO KEEP FLOORS AS CLEAN AS POSSIBLE. ROUGH-INS ARE SHOWN AT

6. ALL "ROUGH-INS" SHOULD BE "UP-WITHIN" AND THEN "OUT-OF" WALLS WHERE

ROUGH-IN DRAWINGS AND SHOP DRAWINGS FOR ACTUAL REQUIREMENTS.

2. DO NOT ROUGH-IN FROM THIS DRAWING. REFER TO F.S.E.C. DIMENSIONED

AND FURNISH ALL WIRING, SWITCHES, CONTROLS, SERVICE VALVES, PIPING, ETC AS REQUIRED.

5. SLOPES TO FD'S SHOULD BE HELD TO A MINIMUM DIMENSION.

1. KITCHEN EQUIPMENT SHALL BE DELIVERED AND ERECTED

PROVIDE ROOM VENTILATION (A/C RECOMMENED) AS REQUIRED

9. PROVIDE VENTILATION, STRUCTURAL SUPPORT, CEILING WORK,

10. EXHAUST HOOD SHALL BE USED FOR VENTILATION OF COOKING EQUIPMENT ONLY.

12. REVIEW ALL ROUGHINS AND SHOP DRAWINGS FROM F.S.E.C. AND

11. PROVIDE ADEQUATE VENTILATION FOR REFRIGERATION

COMPRESSORS, WHETHER AIR OR WATER COOLED.

14. REUSE EXISTING ROUGHINS IF APPLICABLE

ADVISE PRIOR TO ROUGHING IN IF ANY CHANGES ARE REQUIRED.

15. EQUIPMENT NOT BEING REUSED TO BE DISCONNECTED.

19. EQUIPMENT DESIGNATED AS RELOCATED SHALL BE REMOVED FROM SITE, CLEANED, MADE READY

18. EQUIPMENT DESIGNATED AS RELOCATED SHALL BE DISCONNECTED FROM UTILITIES.

17. IF OWNER REQUESTS EXISTING EQUIPMENT BE SALVAGED TURN OVER TO OWNER.

20. EQUIPMENT DESIGNATED AS RELOCATED SHALL BE RE-CONNECTED.

ROOF PENETRATIONS AND FIRE PROOFING AS REQUIRED.

FLOOR GRATES, WALKINS, DUCTS, ETC.

BEVERAGE LINES, ETC.

CORDS, VALVES, GAS HOSES, ETC.).

FURNISH DRAIN WATER TEMPERING KIT(S).

FS

02-02-2024 ISSUED FOR BIDDING

File details come from the government source that posted it. Updated .