This document is a Request for Proposal (RFP) for the Maintenance/Transportation HVAC Replacement project for Midland Public Schools located in Midland, Michigan. The RFP is seeking bids for the replacement of HVAC equipment at the Midland Public Schools Transportation Building. Proposals are due by 2:00 PM on Wednesday, February 14, 2024 and must be submitted in writing to the Midland Public Schools Board of Education. No oral, telephonic, or facsimile proposals will be considered.
The RFP does not provide details on the specific equipment to be replaced or the quantities involved. It also does not mention any site visits, bidder's meetings, award dates, or contract term. Pricing terms, set asides, incumbent contractors, funding requirements and sources, and other salient details are also not included in the RFP document.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 23 0939 01 MPS Transportation - BIDS (1).pdf | ||
| Maintenance Transportation HVAC (1).pdf | ||
| Maintenance Transportation HVAC.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TRANSPORTATION BUILDING - AHU/RTU REPLACEMENT
MIDLAND PUBLIC SHOOLS
600 E. Carpenter Street Midland, MI 48640
DATE: 01/22/2024 ISSUANCE: BIDS/PERMITS
MEP ENGINEERS:
SES
Strategic Energy Solutions
4000 W. Eleven Mile Road Berkley, MI 48072 Phone 248.399.1900 Fax 248.399.1901 www.sesnet.com
SES Project # 23 0939 01
LOCATION:
MIDLAND PUBLIC SCHOOLS TRANSPORTATION
BUILDING
410 E. Hines Road Midland, MI 48640
MAP IMAGE
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text MECHANICAL: M0.0TB MECHANICAL GENERAL INFORMATION MECHANICAL GENERAL INFORMATION M1.1TB MECHANICAL PLANS - TRANSPORTATION BUILDING MECHANICAL PLANS - TRANSPORTATION BUILDING M1.2TB MECHANICAL ROOF PLANS - TRANSPORTATION BUILDING MECHANICAL ROOF PLANS - TRANSPORTATION BUILDING ELECTRICAL: E0.0TB ELECTRICAL GENERAL INFORMATION ELECTRICAL GENERAL INFORMATION E1.1TB ELECTRICAL PLANS - TRANSPORTATION BUILDING ELECTRICAL PLANS - TRANSPORTATION BUILDING E1.2TB ELECTRICAL ROOF PLANS - TRANSPORTATION BUILDINGELECTRICAL ROOF PLANS - TRANSPORTATION BUILDING
AutoCAD SHX Text
C 2023 SES, INC.
MECHANICAL ABBREVIATIONS MECHANICAL ABBREVIATIONSMECHANICAL ABBREVIATIONS MECHANICAL SYMBOLS
DRAWING NOTATION
SECTION
APPLICABLE CODES
AND REGULATIONS
MECHANICAL PIPING SYMBOLS
PIPING LEGEND
M0.0TB
MECHANICAL GENERAL
INFORMATION
SES
Strategic Energy Solutions
Phone 248.399.1900 Fax 248.399.1901 www.sesnet.com
4000 W. Eleven Mile Road Berkley, MI 48072
SES Project #23 0939 01
MIDLAND PUBLIC SCHOOLS
600 East Carpenter Street Midland, MI 48640
MIDLAND PUBLIC SCHOOLS
TRANSPORTATION
BUILDING - AHU/RTU
REPLACEMENT
410 East Hines Road Midland, MI 48640
DRAWING INDEX
AutoCAD SHX Text
HO
AutoCAD SHX Text
HUB OUTLET
AutoCAD SHX Text
GAL
AutoCAD SHX Text
GALLON
AutoCAD SHX Text
FFE
AutoCAD SHX Text
FINISHED FLOOR ELEVATION
AutoCAD SHX Text
CIRC
AutoCAD SHX Text
CIRCULATING
AutoCAD SHX Text T & P
AutoCAD SHX Text
TEMPERATURE AND PRESSURE
AutoCAD SHX Text
SP
AutoCAD SHX Text
STATIC PRESSURE
AutoCAD SHX Text
SQUARE FOOT/SQUARE FEET
AutoCAD SHX Text
SERVICE SINK
AutoCAD SHX Text
SHOWER
AutoCAD SHX Text
SS
AutoCAD SHX Text SqFt / SF
AutoCAD SHX Text
SH
AutoCAD SHX Text
POUNDS PER SQUARE INCH - GAUGE
AutoCAD SHX Text
PSIG
AutoCAD SHX Text
REVOLUTIONS PER MINUTE
AutoCAD SHX Text
REDUCED PRESSURE ZONE
AutoCAD SHX Text
SUPPLY AIR
AutoCAD SHX Text
ROOF SUMP
AutoCAD SHX Text
RELIEF AIR
AutoCAD SHX Text
RETURN AIR
AutoCAD SHX Text
RPM
AutoCAD SHX Text
SA
AutoCAD SHX Text
RS
AutoCAD SHX Text
RPZ
AutoCAD SHX Text
REL.A
AutoCAD SHX Text
RA
AutoCAD SHX Text
POUNDS PER SQUARE INCH - ABSOLUTE
AutoCAD SHX Text
PRESSURE REDUCING VALVE
AutoCAD SHX Text
PRESSURE DROP (FEET OF WATER)
AutoCAD SHX Text
OPPOSED BLADE DAMPER
AutoCAD SHX Text
OPEN ENDED DUCT
AutoCAD SHX Text
OUTSIDE DIAMETER
AutoCAD SHX Text
ON CENTER / CENTER TO CENTER
AutoCAD SHX Text
OUTSIDE AIR
AutoCAD SHX Text
PD
AutoCAD SHX Text
PSIA
AutoCAD SHX Text
PRV
AutoCAD SHX Text
OBD
AutoCAD SHX Text
OED
AutoCAD SHX Text
OD
AutoCAD SHX Text
OC
AutoCAD SHX Text
OA
AutoCAD SHX Text
MANUAL AIR VENT
AutoCAD SHX Text
NOT IN CONTRACT
AutoCAD SHX Text
NORMALLY CLOSED
AutoCAD SHX Text
NOMINAL
AutoCAD SHX Text
NORMALLY OPEN
AutoCAD SHX Text
NOISE CRITERIA
AutoCAD SHX Text
MINIMUM
AutoCAD SHX Text
MISCELLANEOUS
AutoCAD SHX Text
MANHOLE
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
NOM
AutoCAD SHX Text
NIC
AutoCAD SHX Text N.C.
AutoCAD SHX Text
NO
AutoCAD SHX Text
NC
AutoCAD SHX Text
MAV
AutoCAD SHX Text
MIN
AutoCAD SHX Text
MISC
AutoCAD SHX Text
MFR
AutoCAD SHX Text
MECH
AutoCAD SHX Text
MH
AutoCAD SHX Text
1000 BRITISH THERMAL UNITS PER HOUR
AutoCAD SHX Text
POUNDS PER HOUR
AutoCAD SHX Text
LOCKED ROTOR AMPS
AutoCAD SHX Text
LEAVING WET BULB TEMPERATURE
AutoCAD SHX Text
LEAVING DRY BULB TEMPERATURE
AutoCAD SHX Text
MAXIMUM
AutoCAD SHX Text
LAVATORY
AutoCAD SHX Text
LEAVING AIR TEMPERATURE
AutoCAD SHX Text
INTERNAL STATIC PRESSURE
AutoCAD SHX Text
KILOWATT
AutoCAD SHX Text
INDIRECT WASTE
AutoCAD SHX Text
INCHES
AutoCAD SHX Text
INVERT
AutoCAD SHX Text
LRA
AutoCAD SHX Text
MAX
AutoCAD SHX Text
MBH
AutoCAD SHX Text
LWB
AutoCAD SHX Text
LDB
AutoCAD SHX Text
LBS/HR
AutoCAD SHX Text
LAV
AutoCAD SHX Text
ISP
AutoCAD SHX Text
INV
AutoCAD SHX Text
KW
AutoCAD SHX Text
LAT
AutoCAD SHX Text
IW
AutoCAD SHX Text
IN
AutoCAD SHX Text
WALL HYDRANT
AutoCAD SHX Text
WATER GAUGE
AutoCAD SHX Text
VENT THRU ROOF
AutoCAD SHX Text
WATER CLOSET
AutoCAD SHX Text
WET BULB TEMPERATURE
AutoCAD SHX Text
WASTE AND VENT
AutoCAD SHX Text
WG
AutoCAD SHX Text
WH
AutoCAD SHX Text W
AutoCAD SHX Text
WC
AutoCAD SHX Text
WB
AutoCAD SHX Text W&V
AutoCAD SHX Text
VTR
AutoCAD SHX Text
WASTE
AutoCAD SHX Text
HOUR
AutoCAD SHX Text
INVERT ELEVATION
AutoCAD SHX Text
HERTZ
AutoCAD SHX Text
INSIDE DIAMETER
AutoCAD SHX Text
HYDRANT
AutoCAD SHX Text
HORSEPOWER
AutoCAD SHX Text
HEATING
AutoCAD SHX Text
HYD
AutoCAD SHX Text
HZ
AutoCAD SHX Text
IE
AutoCAD SHX Text
ID
AutoCAD SHX Text
HTG
AutoCAD SHX Text
HR
AutoCAD SHX Text
HP
AutoCAD SHX Text
VOLUME DAMPER (MANUALLY ADJUSTABLE)
AutoCAD SHX Text
UNDERWRITERS LABORATORY
AutoCAD SHX Text
UNLESS NOTED OTHERWISE
AutoCAD SHX Text
TEMPERATURE CONTROL
AutoCAD SHX Text
TOTAL STATIC PRESSURE
AutoCAD SHX Text
UNDERGROUND
AutoCAD SHX Text
VD
AutoCAD SHX Text
UNO
AutoCAD SHX Text
UR
AutoCAD SHX Text
UL
AutoCAD SHX Text
URINAL
AutoCAD SHX Text
TSP
AutoCAD SHX Text
TYP
AutoCAD SHX Text
UG
AutoCAD SHX Text
TC
AutoCAD SHX Text
TYPICAL
AutoCAD SHX Text
SMOKE DETECTOR
AutoCAD SHX Text
MOTORIZED DAMPER
AutoCAD SHX Text
VOLUME DAMPER (MANUALLY ADJUSTABLE)
AutoCAD SHX Text
CO2 SENSOR
AutoCAD SHX Text
CROSS SECTION OF SUPPLY AIR DUCT
AutoCAD SHX Text
FLEXIBLE CONNECTION
AutoCAD SHX Text
LINEAR SLOT DIFFUSER
AutoCAD SHX Text
SUPPLY DIFFUSER
AutoCAD SHX Text
RETURN OR EXHAUST GRILLE
AutoCAD SHX Text
TRANSFER GRILLE
AutoCAD SHX Text
FLEXIBLE DUCT CONNECTION TO SUPPLY
AutoCAD SHX Text
CONCENTRIC TRANSITION (DOUBLE LINE)
AutoCAD SHX Text
CONCENTRIC TRANSITION (SINGLE LINE)
AutoCAD SHX Text
ECCENTRIC TRANSITION (SINGLE LINE)
AutoCAD SHX Text
ECCENTRIC TRANSITION (DOUBLE LINE)
AutoCAD SHX Text
RADIUS RECTANGULAR ELBOW
AutoCAD SHX Text
RADIUS ROUND ELBOW
AutoCAD SHX Text
ROUND ELBOW UP
AutoCAD SHX Text
RECTANGULAR ELBOW UP
AutoCAD SHX Text
RECTANGULAR ELBOW DOWN
AutoCAD SHX Text
ROUND ELBOW DOWN
AutoCAD SHX Text
RECTANGULAR TAKE-OFF (SINGLE LINE)
AutoCAD SHX Text
RECTANGULAR TAKE-OFF (DOUBLE LINE)
AutoCAD SHX Text
ROUND TAKE-OFF (SINGLE LINE)
AutoCAD SHX Text
ROUND TAKE-OFF (DOUBLE LINE)
AutoCAD SHX Text
SPIN-IN FITTING (WITH VOLUME DAMPER)
AutoCAD SHX Text
ELBOW (WITH TURNING VANES)
AutoCAD SHX Text
FULL LOAD AMPS
AutoCAD SHX Text
FLA
AutoCAD SHX Text
GALLONS PER HOUR
AutoCAD SHX Text
GALLONS PER MINUTE
AutoCAD SHX Text
FLOOR
AutoCAD SHX Text
FEET
AutoCAD SHX Text
FEET PER MINUTE
AutoCAD SHX Text
FUNNEL FLOOR DRAIN
AutoCAD SHX Text
FLOOR SINK
AutoCAD SHX Text
FACE VELOCITY
AutoCAD SHX Text
FIRE VALVE CABINET
AutoCAD SHX Text
GPM
AutoCAD SHX Text
GPH
AutoCAD SHX Text
FVC
AutoCAD SHX Text
FV
AutoCAD SHX Text
FT
AutoCAD SHX Text
FS
AutoCAD SHX Text
FFD
AutoCAD SHX Text
FPM
AutoCAD SHX Text
FLR
AutoCAD SHX Text
FLEXIBLE CONNECTION
AutoCAD SHX Text
FIRE HOSE VALVE
AutoCAD SHX Text
FLOOR DRAIN
AutoCAD SHX Text
FACE AREA (COIL) / FREE AREA (LOUVER)
AutoCAD SHX Text
DEGREES FAHRENHEIT
AutoCAD SHX Text
FD
AutoCAD SHX Text
FHV
AutoCAD SHX Text
FC
AutoCAD SHX Text
FA
AutoCAD SHX Text
%%DF
AutoCAD SHX Text
ELECTRIC WATER COOLER
AutoCAD SHX Text
EXTERNAL STATIC PRESSURE
AutoCAD SHX Text
ELEVATION
AutoCAD SHX Text
ENTERING AIR TEMPERATURE
AutoCAD SHX Text
EXHAUST AIR
AutoCAD SHX Text
EXPANSION JOINT
AutoCAD SHX Text
EXHAUST FAN
AutoCAD SHX Text
ENERGY MANAGEMENT SYSTEM
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
ELECT
AutoCAD SHX Text
EWC
AutoCAD SHX Text
EWB
AutoCAD SHX Text
ESP
AutoCAD SHX Text
EMS
AutoCAD SHX Text
EJ
AutoCAD SHX Text
EL
AutoCAD SHX Text
EF
AutoCAD SHX Text
EAT
AutoCAD SHX Text
EDB
AutoCAD SHX Text
EA/EXH
AutoCAD SHX Text
DEGREES
AutoCAD SHX Text
DRY BULB TEMPERATURE
AutoCAD SHX Text
DOWN
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
DOMESTIC WATER HEATER
AutoCAD SHX Text
DRAIN TILE CONNECTION
AutoCAD SHX Text
DIRECT DIGITAL CONTROL
AutoCAD SHX Text
CABINET UNIT HEATER
AutoCAD SHX Text
CONTROL VALVE
AutoCAD SHX Text
CONVECTOR
AutoCAD SHX Text
DWH
AutoCAD SHX Text (E)
AutoCAD SHX Text
DTC
AutoCAD SHX Text
DDC
AutoCAD SHX Text
DN
AutoCAD SHX Text
CV
AutoCAD SHX Text
DB
AutoCAD SHX Text
DEG
AutoCAD SHX Text
CUH
AutoCAD SHX Text
CONV
AutoCAD SHX Text
COOLING
AutoCAD SHX Text
CONTINUATION OR CONTINUED
AutoCAD SHX Text
CLEAN OUT
AutoCAD SHX Text
CAPACITY
AutoCAD SHX Text
BRITISH THERMAL UNIT
AutoCAD SHX Text
CUBIC FEET PER HOUR
AutoCAD SHX Text
CONSTANT AIR VOLUME
AutoCAD SHX Text
BACKWATER VALVE
AutoCAD SHX Text
CUBIC FEET PER MINUTE
AutoCAD SHX Text
CO
AutoCAD SHX Text
CONT
AutoCAD SHX Text
CLG
AutoCAD SHX Text
CFM
AutoCAD SHX Text
CFH
AutoCAD SHX Text
CAV
AutoCAD SHX Text
CAP
AutoCAD SHX Text
BWV
AutoCAD SHX Text
BTUH
AutoCAD SHX Text
BTU
AutoCAD SHX Text
ACCESS DOOR
AutoCAD SHX Text
AIR EXTRACTOR
AutoCAD SHX Text
BRAKE HORSEPOWER
AutoCAD SHX Text
BOTTOM OF DUCT
AutoCAD SHX Text
BACKFLOW PREVENTER
AutoCAD SHX Text
AUTOMATIC SPRINKLER RISER
AutoCAD SHX Text
ABOVE FINISHED FLOOR
AutoCAD SHX Text
AIR PRESSURE DROP
AutoCAD SHX Text
AUTOMATIC AIR VENT / AIR ADMITTANCE VALVE
AutoCAD SHX Text
ASR
AutoCAD SHX Text
BOD
AutoCAD SHX Text
BHP
AutoCAD SHX Text
BFP
AutoCAD SHX Text
APD
AutoCAD SHX Text
AFF
AutoCAD SHX Text
AAV
AutoCAD SHX Text
AE
AutoCAD SHX Text
AD
AutoCAD SHX Text
ENTERING WET BULB TEMPERATURE
AutoCAD SHX Text
ENTERING DRY BULB TEMPERATURE
AutoCAD SHX Text
BRITISH THERMAL UNITS PER HOUR
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
ABBREV.
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
ABBREV.
AutoCAD SHX Text
ABBREV.
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
ABBREV.
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text
SD
AutoCAD SHX Text
INCLINED DROP IN DIRECTION OF AIR FLOW
AutoCAD SHX Text
(SINGLE LINE)
AutoCAD SHX Text
INCLINED DROP IN DIRECTION OF AIR FLOW
AutoCAD SHX Text
(DOUBLE LINE)
AutoCAD SHX Text
INCLINED RISE IN DIRECTION OF AIR FLOW
AutoCAD SHX Text
(SINGLE LINE)
AutoCAD SHX Text
INCLINED RISE IN DIRECTION OF AIR FLOW
AutoCAD SHX Text
(DOUBLE LINE)
AutoCAD SHX Text
DIFFUSER
AutoCAD SHX Text
DUCT
AutoCAD SHX Text
CROSS SECTION OF EXHAUST OR RETURN AIR
AutoCAD SHX Text
ORS
AutoCAD SHX Text
OVERFLOW ROOF SUMP
AutoCAD SHX Text
RELATIVE HUMIDITY
AutoCAD SHX Text
RH
AutoCAD SHX Text
REQD
AutoCAD SHX Text
REQUIRED
AutoCAD SHX Text
EXISTING DEVICES OR EQUIPMENT
AutoCAD SHX Text
NEW OR MODIFIED DEVICES OR EQUIPMENT
AutoCAD SHX Text M5.2
AutoCAD SHX Text
AutoCAD SHX Text M5.2
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING SYSTEM COMPONENT TO BE REMOVED
AutoCAD SHX Text
SCALE: 1/4" = 1' - 0"
AutoCAD SHX Text
POINT OF NEW CONNECTION
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text
NEW WORK KEY NOTE NO. 1
AutoCAD SHX Text
DEMOLITION KEY NOTE NO. 1
AutoCAD SHX Text
EQUIPMENT TAG
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
NEW
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
SMOKE DAMPER
AutoCAD SHX Text
FIRE DAMPER (HORIZONTAL)
AutoCAD SHX Text
FIRE DAMPER (VERTICAL)
AutoCAD SHX Text
NEW
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
NEW
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
NEW
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
NEW
AutoCAD SHX Text
HB
AutoCAD SHX Text
HOSE BIBB
AutoCAD SHX Text
PT
AutoCAD SHX Text
PRESSURE / TEMPERATURE PORT
AutoCAD SHX Text
FIRE HYDRANT
AutoCAD SHX Text
FIRE HOSE CABINET
AutoCAD SHX Text
FIRE HOSE RACK
AutoCAD SHX Text
FIRE DEPARTMENT CONNECTION
AutoCAD SHX Text
FHR
AutoCAD SHX Text
FHC
AutoCAD SHX Text
FDC
AutoCAD SHX Text
FH
AutoCAD SHX Text
YEAR
AutoCAD SHX Text
CODE
AutoCAD SHX Text
MICHIGAN BUILDING CODE
AutoCAD SHX Text
MICHIGAN REHABILITATION CODE FOR EXISTING BUILDINGS
AutoCAD SHX Text
MICHIGAN MECHANICAL CODE
AutoCAD SHX Text
INTERNATIONAL FUEL GAS CODE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ICC/ANSI ACCESSIBLE AND USABLE BUILDING & FACILITIES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AMERICANS WITH DISABILITIES ACT ACCESSIBILITIES GUIDELINE (ADA-AG)
AutoCAD SHX Text AIR TERMINAL TAG: IE: DIFFUSER TYPE = S-1 DIFFUSER TYPE = S-1 NECK SIZE = 10x10 CFM = 100 (TYPICAL FOR 2)
AutoCAD SHX Text
MICHIGAN UNIFORM ENERGY CODE
AutoCAD SHX Text
AutoCAD SHX Text
COMBINATION FIRE/SMOKE DAMPER (HORIZONTAL)
AutoCAD SHX Text
COMBINATION FIRE/SMOKE DAMPER (VERTICAL)
AutoCAD SHX Text
ECCENTRIC REDUCER
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
ABBREV.
AutoCAD SHX Text
PIPE ELBOW DOWN
AutoCAD SHX Text
DIRECTION OF FLOW
AutoCAD SHX Text
PIPE ELBOW UP
AutoCAD SHX Text
UNION
AutoCAD SHX Text
CONCENTRIC REDUCER
AutoCAD SHX Text
FLEXIBLE CONNECTION
AutoCAD SHX Text
PIPE GUIDE
AutoCAD SHX Text
PIPE ANCHOR
AutoCAD SHX Text
EXPANSION JOINT
AutoCAD SHX Text
CIRCULATING PUMP
AutoCAD SHX Text
BUTTERFLY VALVE
AutoCAD SHX Text
GLOBE VALVE
AutoCAD SHX Text
ANGLE VALVE
AutoCAD SHX Text
BALL VALVE
AutoCAD SHX Text
ISOLATION VALVE
AutoCAD SHX Text
PIPE CAP OR PLUG
AutoCAD SHX Text
TRAP (PLAN VIEW)
AutoCAD SHX Text
CENTRIFUGAL FAN
AutoCAD SHX Text
CHECK VALVE (SPRING)
AutoCAD SHX Text
PLUG VALVE
AutoCAD SHX Text
NEEDLE VALVE
AutoCAD SHX Text
FLOOR DRAIN / FUNNEL FLOOR DRAIN (ELEVATION)
AutoCAD SHX Text
CLEAN OUT (IN FLOOR)
AutoCAD SHX Text
ROOF SUMP
AutoCAD SHX Text
FLOOR DRAIN / FUNNEL FLOOR DRAIN (PLAN VIEW)
AutoCAD SHX Text
AUTOMATIC GAS SHUT-OFF VALVE
AutoCAD SHX Text
CHECK VALVE (SWING)
AutoCAD SHX Text
BACKFLOW PREVENTER
AutoCAD SHX Text
DIRECTION OF PIPE PITCH
AutoCAD SHX Text
HOSE BIBB, WALL HYDRANT
AutoCAD SHX Text
SPRINKLER HEAD (SIDEWALL)
AutoCAD SHX Text
SIAMESE CONNECTION (YARD)
AutoCAD SHX Text
FIRE HYDRANT
AutoCAD SHX Text
FLOW SWITCH
AutoCAD SHX Text
SPRINKLER HEAD (UPRIGHT)
AutoCAD SHX Text
SIAMESE CONNECTION (WALL MOUNTED)
AutoCAD SHX Text
OUTSIDE SCREW AND YOKE VALVE (OS&Y)
AutoCAD SHX Text
CLEAN OUT (IN LINE)
AutoCAD SHX Text
FLOW MEASURING DEVICE
AutoCAD SHX Text
COMBINATION FLOW MEASURING AND BALANCING DEVICE
AutoCAD SHX Text
BALANCING VALVE
AutoCAD SHX Text
AUTOMATIC AIR VALVE
AutoCAD SHX Text
AAV
AutoCAD SHX Text
MANUAL AIR VALVE
AutoCAD SHX Text
MAV
AutoCAD SHX Text S = SUPPLY = SUPPLY SUPPLY R = RETURN = RETURN RETURN E = EXHAUST = EXHAUST EXHAUST T = TRANSFER= TRANSFERTRANSFER
AutoCAD SHX Text
MINIMUM CIRCUIT AMPACITY
AutoCAD SHX Text
MCA
AutoCAD SHX Text
MAXIMUM OVER-CURRENT PROTECTION
AutoCAD SHX Text
MOP
AutoCAD SHX Text
UNIT HEATER
AutoCAD SHX Text
UH
AutoCAD SHX Text
PIPE TEE DOWN
AutoCAD SHX Text
STRAINER
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
WCO
AutoCAD SHX Text
CLEAN OUT (WALL)
AutoCAD SHX Text S
AutoCAD SHX Text
BFP
AutoCAD SHX Text M
AutoCAD SHX Text
WATER METER ASSEMBLY
AutoCAD SHX Text
PRESSURE REGULATING VALVE
AutoCAD SHX Text
SOLENOID VALVE
AutoCAD SHX Text
CONTROL VALVE (2-WAY / 3-WAY)
AutoCAD SHX Text H
AutoCAD SHX Text T
AutoCAD SHX Text
CO2
AutoCAD SHX Text
RETURN OR EXHAUST / SUPPLY AIR FLOW
AutoCAD SHX Text M
AutoCAD SHX Text
MOTOR OPERATED DAMPER (AUTOMATIC)
AutoCAD SHX Text
MOD
AutoCAD SHX Text
PUMPED SANITARY PIPING
AutoCAD SHX Text
HEATING HOT WATER SUPPLY PIPING
AutoCAD SHX Text
HEATING HOT WATER RETURN PIPING
AutoCAD SHX Text
SANITARY WASTE PIPING
AutoCAD SHX Text
CHILLED WATER SUPPLY PIPING
AutoCAD SHX Text
CHILLED WATER RETURN PIPING
AutoCAD SHX Text
FUEL OIL SUPPLY PIPING
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
ABBREV.
AutoCAD SHX Text
DOMESTIC HOT WATER PIPING
AutoCAD SHX Text
DOMESTIC COLD WATER PIPING
AutoCAD SHX Text
PUMPED STEAM CONDENSATE RETURN PIPING
AutoCAD SHX Text
CONDENSATE DRAIN PIPING
AutoCAD SHX Text
STORM SEWER PIPING
AutoCAD SHX Text
STEAM PIPING
AutoCAD SHX Text
VENT PIPING
AutoCAD SHX Text
FUEL OIL RETURN PIPING
AutoCAD SHX Text
DRAIN TILE
AutoCAD SHX Text
REFRIGERANT LIQUID PIPING
AutoCAD SHX Text
REFRIGERANT SUCTION PIPING
AutoCAD SHX Text
FIRE PROTECTION PIPING
AutoCAD SHX Text
RAIN CONDUCTOR PIPING
AutoCAD SHX Text
GEO HEAT EXCHANGE RETURN
AutoCAD SHX Text
GEO HEAT EXCHANGE SUPPLY
AutoCAD SHX Text
CW
AutoCAD SHX Text
HW
AutoCAD SHX Text
HWR
AutoCAD SHX Text
DOMESTIC HOT WATER RETURN PIPING
AutoCAD SHX Text
BOOSTED-DOMESTIC HOT WATER PIPING
AutoCAD SHX Text
BHW
AutoCAD SHX Text
BOOSTED-DOMESTIC COLD WATER PIPING
AutoCAD SHX Text
BCW
AutoCAD SHX Text
HW(XXX)
AutoCAD SHX Text
FOR
AutoCAD SHX Text
FOS
AutoCAD SHX Text
CHWR
AutoCAD SHX Text
CHWS
AutoCAD SHX Text
CD
AutoCAD SHX Text
CONDENSER WATER SUPPLY PIPING
AutoCAD SHX Text
CONDENSER WATER RETURN PIPING
AutoCAD SHX Text
CWR
AutoCAD SHX Text
CWS
AutoCAD SHX Text
NATURAL GAS PIPING
AutoCAD SHX Text G
AutoCAD SHX Text
GXHR
AutoCAD SHX Text
GXHS
AutoCAD SHX Text
STEAM CONDENSATE RETURN PIPING
AutoCAD SHX Text
CR
AutoCAD SHX Text
HHWR
AutoCAD SHX Text
HHWS
AutoCAD SHX Text
HEAT PUMP LOOP SUPPLY PIPING
AutoCAD SHX Text
HEAT PUMP LOOP RETURN PIPING
AutoCAD SHX Text
HPLR
AutoCAD SHX Text
HPLS
AutoCAD SHX Text
NON POTABLE COLD WATER PIPING
AutoCAD SHX Text
NPCW
AutoCAD SHX Text
DT
AutoCAD SHX Text F
AutoCAD SHX Text
PCR
AutoCAD SHX Text
LOW PRESSURE CONDENSATE PIPING
AutoCAD SHX Text
LPC
AutoCAD SHX Text
HIGH PRESSURE CONDENSATE PIPING
AutoCAD SHX Text
HPC
AutoCAD SHX Text
NITROGEN GAS PIPING
AutoCAD SHX Text N
AutoCAD SHX Text
PSAN
AutoCAD SHX Text
RC
AutoCAD SHX Text
ORC
AutoCAD SHX Text
OVERFLOW RAIN CONDUCTOR PIPING
AutoCAD SHX Text
RL
AutoCAD SHX Text
RS
AutoCAD SHX Text
SAN
AutoCAD SHX Text
ST
AutoCAD SHX Text
STM
AutoCAD SHX Text
HIGH PRESSURE STEAM PIPING
AutoCAD SHX Text
HPS
AutoCAD SHX Text
LOW PRESSURE STEAM PIPING
AutoCAD SHX Text
LPS
AutoCAD SHX Text V
AutoCAD SHX Text
COMPRESSED AIR PIPING
AutoCAD SHX Text
CA
AutoCAD SHX Text
VACUUM PIPING
AutoCAD SHX Text
VAC
AutoCAD SHX Text
OXYGEN GAS PIPING
AutoCAD SHX Text O2
AutoCAD SHX Text
MEDICAL AIR PIPING
AutoCAD SHX Text
MA
AutoCAD SHX Text
PUMPED STORM PIPING
AutoCAD SHX Text
PST
AutoCAD SHX Text
HOT GAS BY-PASS PIPING
AutoCAD SHX Text
HGB
AutoCAD SHX Text
TEMPERED WATER PIPING
AutoCAD SHX Text
TW
AutoCAD SHX Text
THERMOSTAT OR TEMPERATURE SENSOR
AutoCAD SHX Text
HUMIDISTAT OR HUMIDITY SENSOR
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text S-1
AutoCAD SHX Text 10x10
AutoCAD SHX Text 100-2
AutoCAD SHX Text
FURNISHED
AutoCAD SHX Text
FURN
AutoCAD SHX Text
INSTALLED
AutoCAD SHX Text
INST
AutoCAD SHX Text
SHEET M5.2 ON WHICH SECTION IS CUT (ENLARGED PARTIAL PLAN SIMILAR)
AutoCAD SHX Text
SECTION NO. 6
AutoCAD SHX Text
SECTION NO. 4
AutoCAD SHX Text
SHEET M5.2 ON WHICH SECTION DRAWN
AutoCAD SHX Text
%%UEF-1
AutoCAD SHX Text
FS
AutoCAD SHX Text S
AutoCAD SHX Text
BACKWATER VALVE
AutoCAD SHX Text
DOMESTIC HOT WATER PIPING CIRCULATED AT XXX TEMPERATURE
AutoCAD SHX Text
TRANSFER AIR DUCT
AutoCAD SHX Text
TD
AutoCAD SHX Text
JWG
AutoCAD SHX Text
NCS
AutoCAD SHX Text
SHEET TITLE:
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESIGNER:
AutoCAD SHX Text
ENGINEER:
AutoCAD SHX Text
ISSUED
AutoCAD SHX Text
C 2023 SES, INC.
AutoCAD SHX Text R
AutoCAD SHX Text
SHEET NUMBER:
AutoCAD SHX Text R
AutoCAD SHX Text
PROJECT:
AutoCAD SHX Text Seal:
AutoCAD SHX Text
ISSUED FOR:
AutoCAD SHX Text
CLIENT:
AutoCAD SHX Text 01/22/24
AutoCAD SHX Text
BIDS/PERMITS
AutoCAD SHX Text
SHT NO
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
M0.0TB
AutoCAD SHX Text
MECHANICAL GENERAL INFORMATION
AutoCAD SHX Text
M1.1TB
AutoCAD SHX Text
MECHANICAL PLANS - TRANSPORTATION BUILDING
AutoCAD SHX Text
M1.2TB
MECHANICAL ROOF PLANS - TRANSPORTATION BUILDING
MECHANICAL DEMOLITION NOTES HVAC GENERAL NOTESDEMOLITION KEYED NOTES
KEYED NOTES
SES
Strategic Energy Solutions
Phone 248.399.1900 Fax 248.399.1901 www.sesnet.com
4000 W. Eleven Mile Road Berkley, MI 48072
SES Project #23 0939 01
MIDLAND PUBLIC SCHOOLS
600 East Carpenter Street Midland, MI 48640
MIDLAND PUBLIC SCHOOLS
TRANSPORTATION
BUILDING - AHU/RTU
REPLACEMENT
410 East Hines Road Midland, MI 48640
NOT TO SCALE
KEY PLAN
M1.1TB
MECHANICAL PLANS -
TRANSPORTATION
BUILDING
PARTIAL MECHANICAL DEMO PLAN PARTIAL MECHANICAL PLAN
AutoCAD SHX Text %%uOFFICE
AutoCAD SHX Text %%uOFFICE
AutoCAD SHX Text %%uOFFICE
AutoCAD SHX Text
%%UVESTIBULE
AutoCAD SHX Text
%%UAREA
AutoCAD SHX Text
%%UOFFICE
AutoCAD SHX Text %%uWELDING SHOP
AutoCAD SHX Text %%uMEN
AutoCAD SHX Text %%uWOMEN
AutoCAD SHX Text %%uDRIVERS
AutoCAD SHX Text %%uLOUNGE
AutoCAD SHX Text
%%UCORR.
AutoCAD SHX Text
%%UWOOD STORAGE
AutoCAD SHX Text %%uCARPENTRY SHOP
AutoCAD SHX Text %%uLOADING & RECEIVING
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
SHEETMETAL
AutoCAD SHX Text
PAINTING
AutoCAD SHX Text
SHOP
AutoCAD SHX Text
TOOL RM.
AutoCAD SHX Text
MECH. RM.
AutoCAD SHX Text
PLUMBING SHOP
AutoCAD SHX Text
LUNCH RM.
AutoCAD SHX Text
BOLT RM.
AutoCAD SHX Text
UP
AutoCAD SHX Text D.F.
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text 12x12
AutoCAD SHX Text 20x14
AutoCAD SHX Text
AutoCAD SHX Text 16x12
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text 10x10
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 12x12
AutoCAD SHX Text
AutoCAD SHX Text 12x12
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text
(E)FTR
AutoCAD SHX Text (E)G
AutoCAD SHX Text
3/4 UP
AutoCAD SHX Text 16x20 SA & RA UP
AutoCAD SHX Text
(E)CONV
AutoCAD SHX Text 16x18
AutoCAD SHX Text
(E)RC
AutoCAD SHX Text
(E)FTR
AutoCAD SHX Text
(E)OA INTAKE LOUVER
AutoCAD SHX Text
(E)AHU AHU (MEZZ.)
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text
(E)CUH
AutoCAD SHX Text
(E)CUH
AutoCAD SHX Text
(E)FTR
AutoCAD SHX Text
(E)FTR
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text
1. THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL EXTENT OF THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL EXTENT OF WORK TO BE PERFORMED. THE EXACT EXTENT OF DEMOLITION SHALL BE AS REQUIRED BY THE NEW WORK. 2. PRIOR TO COMMENCEMENT OF WORK, CONTRACTOR SHALL VISIT THE SITE AND PRIOR TO COMMENCEMENT OF WORK, CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH EXISTING SITE CONDITIONS, SYSTEMS, AND UTILITIES. NOTIFY ARCHITECT OF ANY INTERFERENCES OR DISCREPANCIES. 3. VERIFY DEPTH, SIZE, LOCATIONS AND CONDITION OF EXISTING UTILITIES IN THE VERIFY DEPTH, SIZE, LOCATIONS AND CONDITION OF EXISTING UTILITIES IN THE FIELD, INCLUDING POINTS OF CONNECTION PRIOR TO STARTING ANY WORK. 4. ANY INTERRUPTIONS OF EXISTING SERVICES AND/OR EQUIPMENT SHALL BE ANY INTERRUPTIONS OF EXISTING SERVICES AND/OR EQUIPMENT SHALL BE PERFORMED AT A TIME APPROVED IN ADVANCE BY THE OWNER'S REPRESENTATIVE SO AS NOT TO INTERFERE WITH THE PRESENT BUILDING'S OPERATION. 5. ALL ITEMS ON DEMOLITION PLAN SHALL BE CONSIDERED EXISTING UNLESS ALL ITEMS ON DEMOLITION PLAN SHALL BE CONSIDERED EXISTING UNLESS OTHERWISE NOTED. ALL WORK INDICATED ON PLANS HAS BEEN LOCATED PER EXISTING DRAWINGS AND/OR FIELD OBSERVATION AND REQUIRES FIELD VERIFICATION. 6. ALL ITEMS INDICATED WITH CROSS-HATCHING SHALL BE REMOVED COMPLETE, ALL ITEMS INDICATED WITH CROSS-HATCHING SHALL BE REMOVED COMPLETE, WITH ALL RELATED ITEMS INCLUDING HANGERS, SUPPORTS, INSULATION, CONTROLS, ETC. CAP ALL OPEN ENDED PIPES AND DUCTS. 7. ALL EXISTING WORK TO REMAIN SHALL BE PROTECTED FROM DAMAGE. WHERE ALL EXISTING WORK TO REMAIN SHALL BE PROTECTED FROM DAMAGE. WHERE DUCT OR PIPE INSULATION HAS BEEN DAMAGED DURING DEMOLITION, THE CONTRACTOR SHALL REPAIR INSULATION AS REQUIRED TO MATCH EXISTING. 8. THE OWNER SHALL HAVE FIRST RIGHT OF REFUSAL ON ALL EQUIPMENT BEING THE OWNER SHALL HAVE FIRST RIGHT OF REFUSAL ON ALL EQUIPMENT BEING REMOVED. ALL ITEMS REMOVED SHALL BE LEGALLY DISPOSED OF. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL EXISTING RELOCATED AND OWNER PROVIDED EQUIPMENT.
AutoCAD SHX Text
1. THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL EXTENT OF THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL EXTENT OF THE WORK. PROVIDE HVAC SYSTEMS COMPLETE PER SPECIFICATION, SMACNA STANDARDS, AND PER APPLICABLE CODES INCLUDING ALL NECESSARY OFFSETS, FITTINGS, SPECIAL RADIUS OR MITERED ELBOWS WHICH ARE REQUIRED DUE TO SPACE CONSTRAINTS OR STRUCTURAL CONDITIONS OR OTHER CONDITIONS. 2. CONTRACTOR SHALL COORDINATE THEIR WORK WITH THE WORK OF ALL OTHER CONTRACTOR SHALL COORDINATE THEIR WORK WITH THE WORK OF ALL OTHER TRADES. ALL DUCTWORK IS TO BE ROUTED AS HIGH A POSSIBLE. PROVIDE ACCESS AROUND ALL NEW EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS. VERIFY ALL CLEARANCES PRIOR TO THE FABRICATION OF ANY WORK. 3. DUCTWORK/PIPING SHALL BE ROUTED AS HIGH AS POSSIBLE AND SHALL NOT DUCTWORK/PIPING SHALL BE ROUTED AS HIGH AS POSSIBLE AND SHALL NOT BE LOCATED OVER ELECTRICAL EQUIPMENT/PANELS. PROVIDE REQUIRED CLEARANCE IN FRONT OF ELECTRICAL EQUIPMENT. DUCTWORK/PIPING SHALL NOT INTERFERE WITH ELECTRICAL EQUIPMENT CLEARANCE. 4. DUCTWORK/PIPING SHALL NOT BE INSTALLED IN A LOCATION THAT RESTRICTS DUCTWORK/PIPING SHALL NOT BE INSTALLED IN A LOCATION THAT RESTRICTS THE ACCESS TO MECHANICAL DEVICES REQUIRING ACCESS. 5. THE CONTRACTOR SHALL PROVIDE ALL MISCELLANEOUS SUPPORTING STEEL, THE CONTRACTOR SHALL PROVIDE ALL MISCELLANEOUS SUPPORTING STEEL, ETC. FOR THE PROPER INSTALLATION OF ALL MECHANICAL SYSTEMS. 6. COORDINATE FLOOR, WALL, ROOF PENETRATIONS, LOUVER SIZES, PAD COORDINATE FLOOR, WALL, ROOF PENETRATIONS, LOUVER SIZES, PAD LOCATIONS ETC. WITH ARCHITECTURAL TRADES. SEAL ALL PIPING AND DUCT PENETRATIONS. 7. BRANCH DUCTWORK TO GRILLES, REGISTERS AND DIFFUSERS SHALL BE THE BRANCH DUCTWORK TO GRILLES, REGISTERS AND DIFFUSERS SHALL BE THE SAME SIZE AS THE GRILLE, REGISTER OR DIFFUSER NECK SIZE WHERE NO DUCT SIZE IS INDICATED ON PLAN. 8. MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 5'-0". MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 5'-0". 9. PROVIDE CODE REQUIRED CLEARANCE/ACCESS DOORS FOR DAMPERS, VALVES, PROVIDE CODE REQUIRED CLEARANCE/ACCESS DOORS FOR DAMPERS, VALVES, AND CLEANOUTS LOCATED IN WALLS OR ABOVE HARD CEILINGS. COORDINATE LOCATIONS WITH ARCHITECT. REFER TO ARCHITECTURAL PLANS FOR CEILING TYPES. 10. CONNECTION TO EQUIPMENT SHALL BE VERIFIED WITH MANUFACTURER'S CONNECTION TO EQUIPMENT SHALL BE VERIFIED WITH MANUFACTURER'S CERTIFIED DRAWINGS. TRANSITIONS TO ALL EQUIPMENT SHALL BE VERIFIED AND PROVIDED FOR EQUIPMENT FURNISHED.
AutoCAD SHX Text %%uOFFICE
AutoCAD SHX Text %%uOFFICE
AutoCAD SHX Text %%uOFFICE
AutoCAD SHX Text %%uWELDING SHOP
AutoCAD SHX Text %%uMEN
AutoCAD SHX Text %%uWOMEN
AutoCAD SHX Text %%uDRIVERS
AutoCAD SHX Text %%uLOUNGE
AutoCAD SHX Text
%%UCORR.
AutoCAD SHX Text
%%UWOOD STORAGE
AutoCAD SHX Text %%uCARPENTRY SHOP
AutoCAD SHX Text %%uLOADING & RECEIVING
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
SHEETMETAL
AutoCAD SHX Text
PAINTING
AutoCAD SHX Text
SHOP
AutoCAD SHX Text
TOOL RM.
AutoCAD SHX Text
MECH. RM.
AutoCAD SHX Text
PLUMBING SHOP
AutoCAD SHX Text
LUNCH RM.
AutoCAD SHX Text
BOLT RM.
AutoCAD SHX Text
UP
AutoCAD SHX Text D.F.
AutoCAD SHX Text
%%UVESTIBULE
AutoCAD SHX Text
%%UOFFICE
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text 20x14
AutoCAD SHX Text 16x12
AutoCAD SHX Text 10x10
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 12x12
AutoCAD SHX Text
AutoCAD SHX Text 12x12
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text
(E)FTR
AutoCAD SHX Text (E)G
AutoCAD SHX Text
(E)CONV
AutoCAD SHX Text
(E)RC
AutoCAD SHX Text
(E)FTR
AutoCAD SHX Text
(E)OA INTAKE LOUVER
AutoCAD SHX Text 14x14 W/BELLMOUTH
AutoCAD SHX Text 20x16 SA&RA UP TO RTU
AutoCAD SHX Text 20x16
AutoCAD SHX Text 14x14
AutoCAD SHX Text 14x12
AutoCAD SHX Text 14x14
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 14x14
AutoCAD SHX Text
(E)FTR
AutoCAD SHX Text T
AutoCAD SHX Text
(E)FTR
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text
(E)CUH
AutoCAD SHX Text
(E)CUH
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text
TO RTU-1. CONFIRM EXACT LOCATION WITH OWNER
AutoCAD SHX Text
1. REMOVE EXISTING INDOOR AHU, DUCTWORK AS INDICATED, CONDENSING UNIT REMOVE EXISTING INDOOR AHU, DUCTWORK AS INDICATED, CONDENSING UNIT ON ROOF, AND HEATING HOT WATER PIPING BACK TO MAIN. 2. REMOVE RTU AND DUCTWORK AS INDICATED. REMOVE GAS PIPING AND REMOVE RTU AND DUCTWORK AS INDICATED. REMOVE GAS PIPING AND PREPARE FOR CONNECTION TO NEW RTU.
AutoCAD SHX Text
1. PROVIDE METAL INSULATED PANEL TO BLANK OFF EXISTING OA INTAKE LOUVER. PROVIDE METAL INSULATED PANEL TO BLANK OFF EXISTING OA INTAKE LOUVER. 2. 1" GAS UP TO RTU. PROVIDE DIRT LEG, UNION AND SHUT-OFF VALVE AT 1" GAS UP TO RTU. PROVIDE DIRT LEG, UNION AND SHUT-OFF VALVE AT UNIT CONNECTION. COORDINATE EXACT LOCATION WITH UNIT PROVIDED. PROVIDE ROOF FLASHING CONE AND COUNTER FLASHING AT ROOF PENETRATION. 3. REMOVE AND REPLACE FTR OR CONVECTOR CONTROLS WITH DDC CONTROLS. REMOVE AND REPLACE FTR OR CONVECTOR CONTROLS WITH DDC CONTROLS. INCLUDE NEW CONTROL VALVE, TEMPERATURE SENSOR AND ZONE CONTROLLER. FIELD VERIFY WHICH SENSOR SERVES EACH PIECE OF EQUIPMENT. 4. REMOVE AND REPLACE CUH CONTROLS AND TEMPERATURE SENSOR WITH DDC REMOVE AND REPLACE CUH CONTROLS AND TEMPERATURE SENSOR WITH DDC CONTROLS. INCLUDE NEW CONTROLLER, CONTROL VALVE, DAMPER ACTUATORS, TEMPERATURE SENSORS, ETC. AS REQUIRED FOR COMPLETE DDC CONTROL OF THE UNIT.
AutoCAD SHX Text
1. THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL EXTENT OF THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL EXTENT OF THE WORK. PROVIDE HVAC SYSTEMS COMPLETE PER SPECIFICATION, SMACNA STANDARDS, AND PER APPLICABLE CODES INCLUDING ALL NECESSARY OFFSETS, FITTINGS, SPECIAL RADIUS OR MITERED ELBOWS WHICH ARE REQUIRED DUE TO SPACE CONSTRAINTS OR STRUCTURAL CONDITIONS OR OTHER CONDITIONS. 2. CONTRACTOR SHALL COORDINATE THEIR WORK WITH THE WORK OF ALL OTHER CONTRACTOR SHALL COORDINATE THEIR WORK WITH THE WORK OF ALL OTHER TRADES. ALL DUCTWORK IS TO BE ROUTED AS HIGH A POSSIBLE. PROVIDE ACCESS AROUND ALL NEW EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS. VERIFY ALL CLEARANCES PRIOR TO THE FABRICATION OF ANY WORK. 3. DUCTWORK/PIPING SHALL BE ROUTED AS HIGH AS POSSIBLE AND SHALL NOT DUCTWORK/PIPING SHALL BE ROUTED AS HIGH AS POSSIBLE AND SHALL NOT BE LOCATED OVER ELECTRICAL EQUIPMENT/PANELS. PROVIDE REQUIRED CLEARANCE IN FRONT OF ELECTRICAL EQUIPMENT. DUCTWORK/PIPING SHALL NOT INTERFERE WITH ELECTRICAL EQUIPMENT CLEARANCE. 4. DUCTWORK/PIPING SHALL NOT BE INSTALLED IN A LOCATION THAT RESTRICTS DUCTWORK/PIPING SHALL NOT BE INSTALLED IN A LOCATION THAT RESTRICTS THE ACCESS TO MECHANICAL DEVICES REQUIRING ACCESS. 5. THE CONTRACTOR SHALL PROVIDE ALL MISCELLANEOUS SUPPORTING STEEL, THE CONTRACTOR SHALL PROVIDE ALL MISCELLANEOUS SUPPORTING STEEL, ETC. FOR THE PROPER INSTALLATION OF ALL MECHANICAL SYSTEMS. 6. COORDINATE FLOOR, WALL, ROOF PENETRATIONS, LOUVER SIZES, PAD COORDINATE FLOOR, WALL, ROOF PENETRATIONS, LOUVER SIZES, PAD LOCATIONS ETC. WITH ARCHITECTURAL TRADES. SEAL ALL PIPING AND DUCT PENETRATIONS. 7. BRANCH DUCTWORK TO GRILLES, REGISTERS AND DIFFUSERS SHALL BE THE BRANCH DUCTWORK TO GRILLES, REGISTERS AND DIFFUSERS SHALL BE THE SAME SIZE AS THE GRILLE, REGISTER OR DIFFUSER NECK SIZE WHERE NO DUCT SIZE IS INDICATED ON PLAN. 8. MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 5'-0". MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 5'-0". 9. PROVIDE CODE REQUIRED CLEARANCE/ACCESS DOORS FOR DAMPERS, VALVES, PROVIDE CODE REQUIRED CLEARANCE/ACCESS DOORS FOR DAMPERS, VALVES, AND CLEANOUTS LOCATED IN WALLS OR ABOVE HARD CEILINGS. COORDINATE LOCATIONS WITH ARCHITECT. REFER TO ARCHITECTURAL PLANS FOR CEILING TYPES. 10. CONNECTION TO EQUIPMENT SHALL BE VERIFIED WITH MANUFACTURER'S CONNECTION TO EQUIPMENT SHALL BE VERIFIED WITH MANUFACTURER'S CERTIFIED DRAWINGS. TRANSITIONS TO ALL EQUIPMENT SHALL BE VERIFIED AND PROVIDED FOR EQUIPMENT FURNISHED.
AutoCAD SHX Text
SHEET TITLE:
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESIGNER:
AutoCAD SHX Text
ENGINEER:
AutoCAD SHX Text
ISSUED
AutoCAD SHX Text
C 2023 SES, INC.
AutoCAD SHX Text R
AutoCAD SHX Text
SHEET NUMBER:
AutoCAD SHX Text R
AutoCAD SHX Text
PROJECT:
AutoCAD SHX Text Seal:
AutoCAD SHX Text
ISSUED FOR:
AutoCAD SHX Text
CLIENT:
AutoCAD SHX Text 01/22/24
AutoCAD SHX Text
BIDS/PERMITS
AutoCAD SHX Text
JWG
AutoCAD SHX Text
NCS
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1/8" = 1'-0"
AutoCAD SHX Text
SCALE:
1/8" = 1'-0"
MECHANICAL DEMOLITION NOTES HVAC GENERAL NOTESDEMOLITION KEYED NOTES
KEYED NOTES
PACKAGED COMMERCIAL ROOFTOP UNIT SCHEDULE - (DX - GAS)
SES
Strategic Energy Solutions
Phone 248.399.1900 Fax 248.399.1901 www.sesnet.com
4000 W. Eleven Mile Road Berkley, MI 48072
SES Project #23 0939 01
MIDLAND PUBLIC SCHOOLS
600 East Carpenter Street Midland, MI 48640
MIDLAND PUBLIC SCHOOLS
TRANSPORTATION
BUILDING - AHU/RTU
REPLACEMENT
410 East Hines Road Midland, MI 48640
NOT TO SCALE
KEY PLAN
M1.2TB
MECHANICAL ROOF PLANS -
TRANSPORTATION
BUILDING
PARTIAL MECHANICAL ROOF DEMO PLAN PARTIAL MECHANICAL ROOF PLAN
AutoCAD SHX Text
(E)VTR
AutoCAD SHX Text
(E)RTURTU
AutoCAD SHX Text
(E)CUCU
AutoCAD SHX Text
(E)RS
AutoCAD SHX Text
(E)EFEF
AutoCAD SHX Text
1. THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL EXTENT OF THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL EXTENT OF WORK TO BE PERFORMED. THE EXACT EXTENT OF DEMOLITION SHALL BE AS REQUIRED BY THE NEW WORK. 2. PRIOR TO COMMENCEMENT OF WORK, CONTRACTOR SHALL VISIT THE SITE AND PRIOR TO COMMENCEMENT OF WORK, CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH EXISTING SITE CONDITIONS, SYSTEMS, AND UTILITIES. NOTIFY ARCHITECT OF ANY INTERFERENCES OR DISCREPANCIES. 3. VERIFY DEPTH, SIZE, LOCATIONS AND CONDITION OF EXISTING UTILITIES IN THE VERIFY DEPTH, SIZE, LOCATIONS AND CONDITION OF EXISTING UTILITIES IN THE FIELD, INCLUDING POINTS OF CONNECTION PRIOR TO STARTING ANY WORK. 4. ANY INTERRUPTIONS OF EXISTING SERVICES AND/OR EQUIPMENT SHALL BE ANY INTERRUPTIONS OF EXISTING SERVICES AND/OR EQUIPMENT SHALL BE PERFORMED AT A TIME APPROVED IN ADVANCE BY THE OWNER'S REPRESENTATIVE SO AS NOT TO INTERFERE WITH THE PRESENT BUILDING'S OPERATION. 5. ALL ITEMS ON DEMOLITION PLAN SHALL BE CONSIDERED EXISTING UNLESS ALL ITEMS ON DEMOLITION PLAN SHALL BE CONSIDERED EXISTING UNLESS OTHERWISE NOTED. ALL WORK INDICATED ON PLANS HAS BEEN LOCATED PER EXISTING DRAWINGS AND/OR FIELD OBSERVATION AND REQUIRES FIELD VERIFICATION. 6. ALL ITEMS INDICATED WITH CROSS-HATCHING SHALL BE REMOVED COMPLETE, ALL ITEMS INDICATED WITH CROSS-HATCHING SHALL BE REMOVED COMPLETE, WITH ALL RELATED ITEMS INCLUDING HANGERS, SUPPORTS, INSULATION, CONTROLS, ETC. CAP ALL OPEN ENDED PIPES AND DUCTS. 7. ALL EXISTING WORK TO REMAIN SHALL BE PROTECTED FROM DAMAGE. WHERE ALL EXISTING WORK TO REMAIN SHALL BE PROTECTED FROM DAMAGE. WHERE DUCT OR PIPE INSULATION HAS BEEN DAMAGED DURING DEMOLITION, THE CONTRACTOR SHALL REPAIR INSULATION AS REQUIRED TO MATCH EXISTING. 8. THE OWNER SHALL HAVE FIRST RIGHT OF REFUSAL ON ALL EQUIPMENT BEING THE OWNER SHALL HAVE FIRST RIGHT OF REFUSAL ON ALL EQUIPMENT BEING REMOVED. ALL ITEMS REMOVED SHALL BE LEGALLY DISPOSED OF. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL EXISTING RELOCATED AND OWNER PROVIDED EQUIPMENT.
AutoCAD SHX Text
1. THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL EXTENT OF THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL EXTENT OF THE WORK. PROVIDE HVAC SYSTEMS COMPLETE PER SPECIFICATION, SMACNA STANDARDS, AND PER APPLICABLE CODES INCLUDING ALL NECESSARY OFFSETS, FITTINGS, SPECIAL RADIUS OR MITERED ELBOWS WHICH ARE REQUIRED DUE TO SPACE CONSTRAINTS OR STRUCTURAL CONDITIONS OR OTHER CONDITIONS. 2. CONTRACTOR SHALL COORDINATE THEIR WORK WITH THE WORK OF ALL OTHER CONTRACTOR SHALL COORDINATE THEIR WORK WITH THE WORK OF ALL OTHER TRADES. ALL DUCTWORK IS TO BE ROUTED AS HIGH A POSSIBLE. PROVIDE ACCESS AROUND ALL NEW EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS. VERIFY ALL CLEARANCES PRIOR TO THE FABRICATION OF ANY WORK. 3. DUCTWORK/PIPING SHALL BE ROUTED AS HIGH AS POSSIBLE AND SHALL NOT DUCTWORK/PIPING SHALL BE ROUTED AS HIGH AS POSSIBLE AND SHALL NOT BE LOCATED OVER ELECTRICAL EQUIPMENT/PANELS. PROVIDE REQUIRED CLEARANCE IN FRONT OF ELECTRICAL EQUIPMENT. DUCTWORK/PIPING SHALL NOT INTERFERE WITH ELECTRICAL EQUIPMENT CLEARANCE. 4. DUCTWORK/PIPING SHALL NOT BE INSTALLED IN A LOCATION THAT RESTRICTS DUCTWORK/PIPING SHALL NOT BE INSTALLED IN A LOCATION THAT RESTRICTS THE ACCESS TO MECHANICAL DEVICES REQUIRING ACCESS. 5. THE CONTRACTOR SHALL PROVIDE ALL MISCELLANEOUS SUPPORTING STEEL, THE CONTRACTOR SHALL PROVIDE ALL MISCELLANEOUS SUPPORTING STEEL, ETC. FOR THE PROPER INSTALLATION OF ALL MECHANICAL SYSTEMS. 6. COORDINATE FLOOR, WALL, ROOF PENETRATIONS, LOUVER SIZES, PAD COORDINATE FLOOR, WALL, ROOF PENETRATIONS, LOUVER SIZES, PAD LOCATIONS ETC. WITH ARCHITECTURAL TRADES. SEAL ALL PIPING AND DUCT PENETRATIONS. 7. THE CONTRACTOR SHALL REFER TO ARCHITECTURAL REFLECTED CEILING PLANS THE CONTRACTOR SHALL REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF GRILLES, REGISTERS, AND DIFFUSERS. 8. COORDINATE AND PROVIDE ACCESS DOORS IN HARD CEILING AREAS FOR COORDINATE AND PROVIDE ACCESS DOORS IN HARD CEILING AREAS FOR ACCESS TO BALANCING DAMPERS, ETC. REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPES. 9. BRANCH DUCTWORK TO GRILLES, REGISTERS AND DIFFUSERS SHALL BE THE BRANCH DUCTWORK TO GRILLES, REGISTERS AND DIFFUSERS SHALL BE THE SAME SIZE AS THE GRILLE, REGISTER OR DIFFUSER NECK SIZE WHERE NO DUCT SIZE IS INDICATED ON PLAN. 10. MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 5'-0". MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 5'-0". 11. FOR EQUIPMENT VALVING, COMPONENT, AND PIPING ARRANGEMENT, REFER TO FOR EQUIPMENT VALVING, COMPONENT, AND PIPING ARRANGEMENT, REFER TO PIPING DIAGRAMS AND DETAILS. 12. PAINT ALL VISIBLE INTERIOR SURFACES OF EXHAUST/RETURN GRILLES, PAINT ALL VISIBLE INTERIOR SURFACES OF EXHAUST/RETURN GRILLES, REGISTERS AND VISIBLE ASSOCIATED DUCTWORK FLAT BLACK. 13. THE CEILING SPACE IS USED AS A RETURN AIR PLENUM. NO PLASTIC THE CEILING SPACE IS USED AS A RETURN AIR PLENUM. NO PLASTIC HE CEILING SPACE IS USED AS A RETURN AIR PLENUM. NO PLASTIC MATERIALS INCLUDING PVC PIPING, CONDUIT, WIRING, ETC. SHALL BE USED. ALL MATERIAL IN THE CEILING SPACE IS TO BE PLENUM RATED. 14. PROVIDE CODE REQUIRED CLEARANCE/ACCESS DOORS FOR DAMPERS, VALVES, PROVIDE CODE REQUIRED CLEARANCE/ACCESS DOORS FOR DAMPERS, VALVES, AND CLEANOUTS LOCATED IN WALLS OR ABOVE HARD CEILINGS. COORDINATE LOCATIONS WITH ARCHITECT. REFER TO ARCHITECTURAL PLANS FOR CEILING TYPES. 15. DUCTWORK TO AND FROM VAV BOXES/TERMINAL UNITS SHALL BE EQUAL TO DUCTWORK TO AND FROM VAV BOXES/TERMINAL UNITS SHALL BE EQUAL TO THE BOX CONNECTIONS SIZES UNLESS INDICATED OTHERWISE. 16. CONNECTION TO EQUIPMENT SHALL BE VERIFIED WITH MANUFACTURER'S CONNECTION TO EQUIPMENT SHALL BE VERIFIED WITH MANUFACTURER'S CERTIFIED DRAWINGS. TRANSITIONS TO ALL EQUIPMENT SHALL BE VERIFIED AND PROVIDED FOR EQUIPMENT FURNISHED. 17. ALL BRANCH PIPING TO TERMINAL UNITS TO BE 3/4" UNLESS OTHERWISE ALL BRANCH PIPING TO TERMINAL UNITS TO BE 3/4" UNLESS OTHERWISE NOTED. 18. ROOF MOUNTED EQUIPMENT REQUIRING SERVICE SHALL BE LOCATED A MINIMUM ROOF MOUNTED EQUIPMENT REQUIRING SERVICE SHALL BE LOCATED A MINIMUM OF 10 FEET FROM ROOF EDGES. WHERE EQUIPMENT CAN'T BE LOCATED AWAY FROM ROOF EDGE AND GUARD RAILS ARE NOT PROVIDED, PROVIDE PERMANENT FALL ARREST ANCHORAGE CONNECTION DEVICE THAT COMPLIES WITH ANSI/ASSE Z 359.1.
AutoCAD SHX Text
(E)VTR
AutoCAD SHX Text
(E)RS
AutoCAD SHX Text
(E)EFEF
AutoCAD SHX Text
RTU-1
AutoCAD SHX Text
1. REMOVE CONDENSING UNIT, LINE SET AND ROOF CURB. PATCH ROOF TO REMOVE CONDENSING UNIT, LINE SET AND ROOF CURB. PATCH ROOF TO MATCH EXISTING. 2. REMOVE EXISTING RTU. PROVIDE INSULATED CAP ON EXISTING ROOF CURB. REMOVE EXISTING RTU. PROVIDE INSULATED CAP ON EXISTING ROOF CURB. REMOVE GAS PIPING TO THRU ROOF AND PATCH ROOF TO MATCH EXISTING.
AutoCAD SHX Text
1. THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL EXTENT OF THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL EXTENT OF THE WORK. PROVIDE HVAC SYSTEMS COMPLETE PER SPECIFICATION, SMACNA STANDARDS, AND PER APPLICABLE CODES INCLUDING ALL NECESSARY OFFSETS, FITTINGS, SPECIAL RADIUS OR MITERED ELBOWS WHICH ARE REQUIRED DUE TO SPACE CONSTRAINTS OR STRUCTURAL CONDITIONS OR OTHER CONDITIONS. 2. CONTRACTOR SHALL COORDINATE THEIR WORK WITH THE WORK OF ALL OTHER CONTRACTOR SHALL COORDINATE THEIR WORK WITH THE WORK OF ALL OTHER TRADES. ALL DUCTWORK IS TO BE ROUTED AS HIGH A POSSIBLE. PROVIDE ACCESS AROUND ALL NEW EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS. VERIFY ALL CLEARANCES PRIOR TO THE FABRICATION OF ANY WORK. 3. DUCTWORK/PIPING SHALL BE ROUTED AS HIGH AS POSSIBLE AND SHALL NOT DUCTWORK/PIPING SHALL BE ROUTED AS HIGH AS POSSIBLE AND SHALL NOT BE LOCATED OVER ELECTRICAL EQUIPMENT/PANELS. PROVIDE REQUIRED CLEARANCE IN FRONT OF ELECTRICAL EQUIPMENT. DUCTWORK/PIPING SHALL NOT INTERFERE WITH ELECTRICAL EQUIPMENT CLEARANCE. 4. DUCTWORK/PIPING SHALL NOT BE INSTALLED IN A LOCATION THAT RESTRICTS DUCTWORK/PIPING SHALL NOT BE INSTALLED IN A LOCATION THAT RESTRICTS THE ACCESS TO MECHANICAL DEVICES REQUIRING ACCESS. 5. THE CONTRACTOR SHALL PROVIDE ALL MISCELLANEOUS SUPPORTING STEEL, THE CONTRACTOR SHALL PROVIDE ALL MISCELLANEOUS SUPPORTING STEEL, ETC. FOR THE PROPER INSTALLATION OF ALL MECHANICAL SYSTEMS. 6. COORDINATE FLOOR, WALL, ROOF PENETRATIONS, LOUVER SIZES, PAD COORDINATE FLOOR, WALL, ROOF PENETRATIONS, LOUVER SIZES, PAD LOCATIONS ETC. WITH ARCHITECTURAL TRADES. SEAL ALL PIPING AND DUCT PENETRATIONS. 7. THE CONTRACTOR SHALL REFER TO ARCHITECTURAL REFLECTED CEILING PLANS THE CONTRACTOR SHALL REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF GRILLES, REGISTERS, AND DIFFUSERS. 8. COORDINATE AND PROVIDE ACCESS DOORS IN HARD CEILING AREAS FOR COORDINATE AND PROVIDE ACCESS DOORS IN HARD CEILING AREAS FOR ACCESS TO BALANCING DAMPERS, ETC. REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPES. 9. BRANCH DUCTWORK TO GRILLES, REGISTERS AND DIFFUSERS SHALL BE THE BRANCH DUCTWORK TO GRILLES, REGISTERS AND DIFFUSERS SHALL BE THE SAME SIZE AS THE GRILLE, REGISTER OR DIFFUSER NECK SIZE WHERE NO DUCT SIZE IS INDICATED ON PLAN. 10. MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 5'-0". MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 5'-0". 11. FOR EQUIPMENT VALVING, COMPONENT, AND PIPING ARRANGEMENT, REFER TO FOR EQUIPMENT VALVING, COMPONENT, AND PIPING ARRANGEMENT, REFER TO PIPING DIAGRAMS AND DETAILS. 12. PAINT ALL VISIBLE INTERIOR SURFACES OF EXHAUST/RETURN GRILLES, PAINT ALL VISIBLE INTERIOR SURFACES OF EXHAUST/RETURN GRILLES, REGISTERS AND VISIBLE ASSOCIATED DUCTWORK FLAT BLACK. 13. THE CEILING SPACE IS USED AS A RETURN AIR PLENUM. NO PLASTIC THE CEILING SPACE IS USED AS A RETURN AIR PLENUM. NO PLASTIC HE CEILING SPACE IS USED AS A RETURN AIR PLENUM. NO PLASTIC MATERIALS INCLUDING PVC PIPING, CONDUIT, WIRING, ETC. SHALL BE USED. ALL MATERIAL IN THE CEILING SPACE IS TO BE PLENUM RATED. 14. PROVIDE CODE REQUIRED CLEARANCE/ACCESS DOORS FOR DAMPERS, VALVES, PROVIDE CODE REQUIRED CLEARANCE/ACCESS DOORS FOR DAMPERS, VALVES, AND CLEANOUTS LOCATED IN WALLS OR ABOVE HARD CEILINGS. COORDINATE LOCATIONS WITH ARCHITECT. REFER TO ARCHITECTURAL PLANS FOR CEILING TYPES. 15. DUCTWORK TO AND FROM VAV BOXES/TERMINAL UNITS SHALL BE EQUAL TO DUCTWORK TO AND FROM VAV BOXES/TERMINAL UNITS SHALL BE EQUAL TO THE BOX CONNECTIONS SIZES UNLESS INDICATED OTHERWISE. 16. CONNECTION TO EQUIPMENT SHALL BE VERIFIED WITH MANUFACTURER'S CONNECTION TO EQUIPMENT SHALL BE VERIFIED WITH MANUFACTURER'S CERTIFIED DRAWINGS. TRANSITIONS TO ALL EQUIPMENT SHALL BE VERIFIED AND PROVIDED FOR EQUIPMENT FURNISHED. 17. ALL BRANCH PIPING TO TERMINAL UNITS TO BE 3/4" UNLESS OTHERWISE ALL BRANCH PIPING TO TERMINAL UNITS TO BE 3/4" UNLESS OTHERWISE NOTED. 18. ROOF MOUNTED EQUIPMENT REQUIRING SERVICE SHALL BE LOCATED A MINIMUM ROOF MOUNTED EQUIPMENT REQUIRING SERVICE SHALL BE LOCATED A MINIMUM OF 10 FEET FROM ROOF EDGES. WHERE EQUIPMENT CAN'T BE LOCATED AWAY FROM ROOF EDGE AND GUARD RAILS ARE NOT PROVIDED, PROVIDE PERMANENT FALL ARREST ANCHORAGE CONNECTION DEVICE THAT COMPLIES WITH ANSI/ASSE Z 359.1.
AutoCAD SHX Text
1. EXTEND PLUMBING VENT TO 2' ABOVE OUTDOOR AIR INTAKE ON RTU. EXTEND PLUMBING VENT TO 2' ABOVE OUTDOOR AIR INTAKE ON RTU. 2. RTU ON NEW ROOF CURB FLASHED INTO EXISTING ROOF. PROVIDE OPENING RTU ON NEW ROOF CURB FLASHED INTO EXISTING ROOF. PROVIDE OPENING THRU EXISTING PRE-CAST CONCRETE DOUBLE T ROOF STRUCTURE. PROVIDE MISC. STEEL AS REQUIRED TO FRAME AND REINFORCE OPENING. 3. INSULATED CAP ON EXISTING ROOF CURB.INSULATED CAP ON EXISTING ROOF CURB.
AutoCAD SHX Text
UNIT ID
AutoCAD SHX Text
TOTAL SUPPLY (CFM)
AutoCAD SHX Text
DESIGN OA (CFM)
AutoCAD SHX Text
SUPPLY FAN
AutoCAD SHX Text
DX COOLING COIL
AutoCAD SHX Text
NATURAL GAS HEATING SECTION
AutoCAD SHX Text
POWER EXHAUST OR BAROMETRIC RELIEF
AutoCAD SHX Text
FILTER TYPE
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
DISCONNECT
AutoCAD SHX Text
MANUFACTURER/ MODEL NO.
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
ESP (IN WG)
AutoCAD SHX Text
FAN TYPE
AutoCAD SHX Text
DRIVE TYPE
AutoCAD SHX Text
BHP
AutoCAD SHX Text
HP
AutoCAD SHX Text
TOTAL CAPACITY (MBH)
AutoCAD SHX Text
SENSIBLE CAPACITY (MBH)
AutoCAD SHX Text
AIR
AutoCAD SHX Text
MIN. EFFICIENCY (EER/IEER)
AutoCAD SHX Text
REFRIGERANT TYPE
AutoCAD SHX Text
INPUT (MBH)
AutoCAD SHX Text
OUTPUT (MBH)
AutoCAD SHX Text
GAS PRESS. MIN.- MAX. (IN WG)
AutoCAD SHX Text
STAGES OR MODULATION TURNDOWN
AutoCAD SHX Text
BURNER TYPE
AutoCAD SHX Text
EAT (°F)
AutoCAD SHX Text
LAT (°F)
AutoCAD SHX Text
MOCP
AutoCAD SHX Text
MCA
AutoCAD SHX Text
FLA
AutoCAD SHX Text
VOLTS
AutoCAD SHX Text
PHASE
AutoCAD SHX Text
FURN. BY
AutoCAD SHX Text
INST. BY
AutoCAD SHX Text
EDB (°F)
AutoCAD SHX Text
EWB (°F)
AutoCAD SHX Text
LDB (°F)
AutoCAD SHX Text
LWB (°F)
AutoCAD SHX Text
APD (IN WG)
AutoCAD SHX Text
RTU-1
AutoCAD SHX Text 1,950
AutoCAD SHX Text
AutoCAD SHX Text 0.5
AutoCAD SHX Text
SWSI
AutoCAD SHX Text
DIRECT
AutoCAD SHX Text 0.85
AutoCAD SHX Text 4.0
AutoCAD SHX Text 62.1
AutoCAD SHX Text 48.9
AutoCAD SHX Text 80.0
AutoCAD SHX Text 67.0
AutoCAD SHX Text
AutoCAD SHX Text 56.9
AutoCAD SHX Text 0.33
AutoCAD SHX Text 12.8/17.1
AutoCAD SHX Text R-410A
AutoCAD SHX Text
AutoCAD SHX Text 51.2
AutoCAD SHX Text 5-14
AutoCAD SHX Text
5:1 MODULATION
AutoCAD SHX Text
STAINLESS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
BAROMETRIC RELIEF
AutoCAD SHX Text
MERV 8 MERV 14
AutoCAD SHX Text
AutoCAD SHX Text 28.7
AutoCAD SHX Text 25.7
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
MAN.
AutoCAD SHX Text
MAN.
AutoCAD SHX Text
DAIKIN/ DPS005A
AutoCAD SHX Text
NOTES: 1. DRY BULB ECONOMIZER. 2. PROVIDE WITH 24" ROOF CURB.
AutoCAD SHX Text
SHEET TITLE:
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESIGNER:
AutoCAD SHX Text
ENGINEER:
AutoCAD SHX Text
ISSUED
AutoCAD SHX Text
C 2023 SES, INC.
AutoCAD SHX Text R
AutoCAD SHX Text
SHEET NUMBER:
AutoCAD SHX Text R
AutoCAD SHX Text
PROJECT:
AutoCAD SHX Text Seal:
AutoCAD SHX Text
ISSUED FOR:
AutoCAD SHX Text
CLIENT:
AutoCAD SHX Text 01/22/24
AutoCAD SHX Text
BIDS/PERMITS
AutoCAD SHX Text
JWG
AutoCAD SHX Text
NCS
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1/8" = 1'-0"
AutoCAD SHX Text
SCALE:
ELECTRICAL ABBREVIATIONS
DRAWING NOTATION
POWER SYMBOL LISTCOPPER FEEDER SCHEDULE
E0.0TB
ELECTRICAL GENERAL
INFORMATION
SES
Strategic Energy Solutions
Phone 248.399.1900 Fax 248.399.1901 www.sesnet.com
4000 W. Eleven Mile Road Berkley, MI 48072
SES Project #23 0939 01
MIDLAND PUBLIC SCHOOLS
600 East Carpenter Street Midland, MI 48640
MIDLAND PUBLIC SCHOOLS
TRANSPORTATION
BUILDING - AHU/RTU
REPLACEMENT
410 East Hines Road Midland, MI 48640
DRAWING INDEX
AutoCAD SHX Text
TBB
AutoCAD SHX Text
ABBREV.
AutoCAD SHX Text
IG
AutoCAD SHX Text
ISOLATED GROUND
AutoCAD SHX Text
TELEPHONE BACKBOARD
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
RP
AutoCAD SHX Text
LP
AutoCAD SHX Text
RECEPTACLE PANEL
AutoCAD SHX Text
LIGHTING PANEL
AutoCAD SHX Text
AF
AutoCAD SHX Text
AMPERE FUSE/AMPERE FRAME
AutoCAD SHX Text
WP
AutoCAD SHX Text (E)
AutoCAD SHX Text
NIC
AutoCAD SHX Text
WEATHERPROOF
AutoCAD SHX Text
NOT IN CONTRACT
AutoCAD SHX Text
RMC
AutoCAD SHX Text (R)
AutoCAD SHX Text
RIGID METALLIC CONDUIT
AutoCAD SHX Text
RELOCATED EXISTING ELECTRICAL EQUIPMENT
AutoCAD SHX Text
EXISTING ELECTRICAL EQUIPMENT OR WORK
AutoCAD SHX Text
MDP
AutoCAD SHX Text
FACP
AutoCAD SHX Text
ATS
AutoCAD SHX Text
MAIN DISTRIBUTION PANEL
AutoCAD SHX Text
FA
AutoCAD SHX Text
FLA
AutoCAD SHX Text
FIRE ALARM
AutoCAD SHX Text
FULL LOAD AMPS
AutoCAD SHX Text
FIRE ALARM CONTROL PANEL
AutoCAD SHX Text
AUTOMATIC TRANSFER SWITCH
AutoCAD SHX Text T
AutoCAD SHX Text
TRANSFORMER
AutoCAD SHX Text
MAIN CIRCUIT BREAKER
AutoCAD SHX Text
MAIN LUG ONLY
AutoCAD SHX Text
AVAILABLE INTERRUPTING CURRENT (AMPS)
AutoCAD SHX Text
NON-FUSIBLE
AutoCAD SHX Text
NF
AutoCAD SHX Text
MCB
AutoCAD SHX Text
MLO
AutoCAD SHX Text
AIC
AutoCAD SHX Text
GROUND FAULT CIRCUIT INTERRUPTER
AutoCAD SHX Text
GFCI/GFI
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
EQUIPMENT TAG
AutoCAD SHX Text
DEMOLITION KEY NOTE NUMBER 1
AutoCAD SHX Text
CONSTRUCTION KEY NOTE NUMBER 1
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text
EXISTING SYSTEM COMPONENT TO BE REMOVED
AutoCAD SHX Text
LIGHTING FIXTURE TAG
AutoCAD SHX Text
MOTOR - SINGLE PHASE
AutoCAD SHX Text
MOTOR - THREE PHASE
AutoCAD SHX Text
METER
AutoCAD SHX Text M
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
NEW OR MODIFIED DEVICES OR EQUIPMENT
AutoCAD SHX Text
EXISTING DEVICES OR EQUIPMENT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
GROUND
AutoCAD SHX Text
G/GRD
AutoCAD SHX Text
AFF
AutoCAD SHX Text
ABOVE FINISHED FLOOR
AutoCAD SHX Text
CIRCUIT BREAKER
AutoCAD SHX Text
CB
AutoCAD SHX Text
ELECTRICAL METALLIC TUBING
AutoCAD SHX Text
EMT
AutoCAD SHX Text
ELECTRIC WATER COOLER
AutoCAD SHX Text
EWC
AutoCAD SHX Text
HAND-OFF-AUTO
AutoCAD SHX Text
HOA
AutoCAD SHX Text
NATIONAL ELECTRICAL MANUFACTURERS ASSOC.
AutoCAD SHX Text
NEMA
AutoCAD SHX Text
POLE
AutoCAD SHX Text P
AutoCAD SHX Text
TYP.
AutoCAD SHX Text
TYPICAL
AutoCAD SHX Text
NEW OR MODIFIED UNDERGROUND WIRING
AutoCAD SHX Text
REMOVE AND REINSTALL
AutoCAD SHX Text
(RR)
AutoCAD SHX Text
WG
AutoCAD SHX Text
WIRE GUARD
AutoCAD SHX Text C
AutoCAD SHX Text
CONDUIT OR CEILING MOUNTED
AutoCAD SHX Text
CONDUIT DOWN
AutoCAD SHX Text
CONDUIT UP
AutoCAD SHX Text
POWER RECEPTACLE - DUPLEX TYPE
AutoCAD SHX Text
POWER RECEPTACLE - SIMPLEX TYPE
AutoCAD SHX Text
POWER RECEPTACLE - RECESSED FLOOR TYPE
AutoCAD SHX Text
POWER RECEPTACLE - SPECIALTY TYPE
AutoCAD SHX Text
POWER RECEPTACLE - DUPLEX 6" ABOVE COUNTER
AutoCAD SHX Text
POWER RECEPTACLE - QUADRUPLEX TYPE
AutoCAD SHX Text
DISCONNECT SWITCH - NON FUSED
AutoCAD SHX Text
DISCONNECT SWITCH - FUSED
AutoCAD SHX Text
DISCONNECT SWITCH - COMB. MOTOR STARTER
AutoCAD SHX Text
ELECTRICAL PANEL
AutoCAD SHX Text
GROUNDING BAR
AutoCAD SHX Text
GROUND
AutoCAD SHX Text
GROUNDING ROD
AutoCAD SHX Text
JUNCTION BOX
AutoCAD SHX Text J
AutoCAD SHX Text
MOTOR RATED SWITCH
AutoCAD SHX Text S
AutoCAD SHX Text M
AutoCAD SHX Text
TIME CLOCK
AutoCAD SHX Text
TC
AutoCAD SHX Text NOTES: 1. ALL DEVICE RATINGS/SIZES SHALL BE COORDINATED WITH PLANS ALL DEVICE RATINGS/SIZES SHALL BE COORDINATED WITH PLANS AND SCHEDULES.
AutoCAD SHX Text A
AutoCAD SHX Text
AMPERE
AutoCAD SHX Text
AMPERE TRIP
AutoCAD SHX Text
AT
AutoCAD SHX Text
AWG
AutoCAD SHX Text
AMERICAN WIRE GAUGE
AutoCAD SHX Text
CURRENT TRANSFORMER
AutoCAD SHX Text
CT
AutoCAD SHX Text
COPPER
AutoCAD SHX Text
CU
AutoCAD SHX Text
DISCONNECT
AutoCAD SHX Text
DISC
AutoCAD SHX Text
DIAMETER
AutoCAD SHX Text
DIA
AutoCAD SHX Text
EMERGENCY POWER OFF
AutoCAD SHX Text
EPO
AutoCAD SHX Text F
AutoCAD SHX Text
FUSE
AutoCAD SHX Text
HORSEPOWER
AutoCAD SHX Text
HP
AutoCAD SHX Text
KV
AutoCAD SHX Text
KILOVOLT
AutoCAD SHX Text
KVA
AutoCAD SHX Text
KILOVOLT AMPERE
AutoCAD SHX Text
KW
AutoCAD SHX Text
KILOWATT
AutoCAD SHX Text
KWH
AutoCAD SHX Text
KILOWATT HOUR
AutoCAD SHX Text
MAXIMUM
AutoCAD SHX Text
MAX
AutoCAD SHX Text
MINIMUM
AutoCAD SHX Text
MIN
AutoCAD SHX Text
NATIONAL ELECTRICAL CODE
AutoCAD SHX Text
NEC
AutoCAD SHX Text
NEUTRAL
AutoCAD…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .