23-001 Exhibit A- Materials Location and Identification.xlsx

XLSX spreadsheet 19 KB Posted

Attached to
TECHNICIAN LABOR AND MATERIALS FOR CABLE INSTALLATION AND TERMINATION WITHIN THE ANAMOSA STATE PENNITENTIARY
Solicitation number
23-001
Issued by
Jones County, Iowa

About this file

The document is an Exhibit A - Materials Location and Identification for an Invitation to Bid (ITB) issued by the Iowa Communications Network (ICN) on behalf of the Anamosa State Penitentiary (ASP). The ITB seeks bids from qualified vendors to provide technician labor and materials for horizontal and vertical copper and fiber optic cable installation and termination within the Anamosa State Penitentiary campus. The exhibit details the materials required, including quantities of various conduit sizes, cable types, and termination components. No specific bid due date or award date is provided, but the order in which the buildings are to be cabled has yet to be determined, and ICN/ASP reserves the right to add or delete drops in any of the buildings.

The pricing terms and funding sources are not explicitly stated, but the vendor is expected to provide a quote for each material quantity. There is no mention of set-asides, incumbents, or specific funding requirements. The current environment appears to involve the need to upgrade and expand the cabling infrastructure across multiple buildings and campuses within the Anamosa State Penitentiary.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Materials

ASP ITB Exhibit A - Materials Location and Identification

Cabel location Building # Phones Provided by ICN/Lumen, for information only Cable Only Analog for information only PVC Conduit 3/4" in Feet **PER ASP** * All tunnel conduit need to be PVC, CE4X1C or the equivalent EMT Conduit 3/4" in Feet Rigid Conduit 3/4" in Feet EMT Conduit 1" in Feet Rigid Conduit 1" in Feet EMT Conduit 1.5" in Feet Rigid Conduit 1.5" in Feet EMT Conduit 2" in Feet EMT Conduit 4" in Feet Surface mount Raceway: Legrand V700 Series Wiremold Steel Raceway in Feet or the equivalent PANDUIT CAT6 PLENUM BLUE - PUP6004BU-W (6P4P24-BL-P-PAN-TP) Single Mode inside / outside OS2 6 or 12 strand Fiber Optic cable 6 strd= PDP006AB0707-I/O-C4(YEL) and 12 strd= PDP012AB0707-I/O-C4(YEL) or the equivalent SM OS2 Fiber Jumper 1-meter LC to LC OR-810-LL7-003 / Graybar part # or the equivalent Panduit Cat6 Blue 3' patch cord (UTP28SP3BU) Panduit 24 port Patch Panel (CPPL24WBLY) Surge protector / power strip for cabinets - Provided by Lumen or ICN Weather Proof boxes 10"x 6"x 6" for Tunnel phones (JBXH12126=box / LPCG507=sealent for the box) or equivalent Chatworth 6RU wall mount (11754-719) Panduit Fiber adapter panel (FAP6WBUDLCZ) or Corning Fiber adaptor panel (CCH-CP06-A9) Panduit Rack mount Fiber Dist. Panel (FCE1U) Allen Tel 25 pair Male AMP end (25-3-PX-10-GY) Panduit 24 port punch down (DP245E88TGY) Panduit LC single mode OS1/OS2 fiber ends (FLCSSCBUY) or equivalent Panduit Cat6 Blue Jacks (CJ688TGBU) Panduit Cat6 Blue 14' patch cord (UTPSP14BUY) Pentair/Caddy J-Hooks (appropriate type and size TBD while on site by vendor) Panduit faceplates (CFP1IW / CFP2IW / CFP4IW - to be determined while on site by vendor)

448200
Social services closet 2nd Fl Bldg#235431111112
Conduit or MPLS in walls2A1031120201800
Conduit or MPLS in walls2B1972103250
2B.12050475
Conduit or MPLS in walls1C516010720
Conduit or MPLS in walls1D2230800
55 (Towers 5 & 6)201400
55 (Towers 5 & 6)2257501400422212
Admin MDF Basement Bldg#12362111
NOTE: 4" conduit & Pull Box from Basement to 3rd floor with 2" stubs North & South each floor into drop ceilings.1A52608060875
1B1331402400
1C10901700
1D2230900
Security Office 2fl Bldg#311411
1B57010375
1C ASP Pulled4
3A150200
Upper Rotunda 2nd Fl Bldg# 31811
1C ASP Pulled3
3C23515325
Rotunda Gates 3&4 1st Fl Bldg#31911
1B7130101000
4/5A120100
Chapel Mechanical Rm 3rd Fl Bldg#311211
ES1.1520040875
3A110012200
3C ASP Pulled3
Store Rm 1st Fl Bldg# 652211111112
6A/B21100250
6C/D/E5145060480
7A312501000
Building 5 & Tower 1 share conduit4/5A212752751
54 (Towers 1, 2, 3,4)5010002250
54 (Towers 1, 2, 3,4)51000160084224212
Green house Bldg#101111
10A1150150
Clothing Rm 1st Fl Bldg#112101111
11A6600600
11B22500500
Basement Bldg# 12281111
12B/C12250400
13A111300430
Tunnel24504502
Soap Factory 2fl Bldg#142311
14A/B3375375
License Plate 2nd Fl Bldg#151311
15330030011
Furniture Shop 2nd Fl Bldg#171101111
Bldg. 17, 18, 19, NEED LIFT17A3200200
18A21100225450
19A215075560
Tunnel260011002
Maint/Carpentry 1stfl Bldg#221151
LIFT WILL BE NEEDED20, 21, 22, 23A736501751525
21, 22, 23B31750750
LUD Basement Bldg# 81151
8A4
All phones need 2' patch cord in Cab.8B3
2nd Fl to Basement Tie = Cables 4 cables8C250200
8D2
Power House Basement Bldg#25131
252175300
25A1200200
IPI Warehouse1 upper level Bldg#2626111
26A31200200
26 B, C share conduit26B16565
26C165130
Pump House 1st Fl Bldg#32111
3213030
Dairy Barn 1st Fl Bldg#36141
362125250
TOTAL MATERIAL QUANTITY162382410506985100057575022510002378032030815300042234261644858848448200

VENDOR ESTIMATED PRICE FOR EACH MATERIAL QUANTITY COLUMN TOTAL $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $

NOTES:
1) Where applicable, a part number has been provided. If vendor proposes an alternative, vendor shall provide a cut sheet for ICN, ASP consideration.
2) Some conduits will need pull boxes and/or junction boxes / the conduit connecting floors in the Admin building will need pull boxes on every floor to acomadat the 4" conduit pathway.
3) Conduit size may vary depending on the cable type/brand installed, vendor to adjust as needed.
4) All outdoor conduit requires rigid and attached to handrails unless approved by ASP staff .
5) All indoor conduit requires EMT.
6) All Tunnel conduit requires PVC.
7) Unless identified otherwise, Vendor shall quote and use Panduit products.
8) There are locations Vendor will need to provide a lift to reach the installation point.
9) The order in which the buildings are to be cabled has yet to be determined.
10) ICN or ASP reserves the right to add/delete drops in any of the buildings.

File details come from the government source that posted it. Updated .