Mobile Weapon Cleaning Trailers Statement of Work
The MTARNG continues to reduce and eliminate lead dust contamination and exposure to our Service Members inside of all MTARNG indoor facilities. Many of our Armories contain indoor firing ranges (IFRs) that are no longer used and continuous effort to clean, abate, and contain lead leaching residue is ongoing. During wipe sample procedures to identify any residual lead dust contamination from the IFRs, residual lead dust contamination above the permissible exposure limit (PEL) were identified in other areas throughout our facilities. Weapons cleaning inside the armories once completing Individual Weapons Qualification (IWQ) was determined to be the source of these residual lead dust levels.
In an effort to eliminate the source of residual lead dust contamination, the MTARNG seeks to identify ways to clean weapons on the range immediately following IWQ and prevent bringing the source of residual lead dust contamination back into the armories.
The MTARNG is looking to purchase two (2) separate weapons trailers capable of cleaning multiple weapons (depending on weapon type) simultaneously in timely fashion to prevent Soldier down time and or delays to additional training requirements.
Characteristics must have:
Ultra-sonic cleaning and Lubrication technology that can clean from M-9/M-17 pistols to MK19 grenade launcher and accommodate 4-8 systems depending on different weapon modifications.
Ultrasonic tanks need to be stainless steel and designed to heat liquid and employ sound waves to break up carbon and residue in ALL areas of the weapons.
Chemicals used in the solution must not be hazardous to humans, animals, or aquatics and must not produce no hazardous waste bi-product filtered through a collection filter system.
Lead and carbon residue should be captured inside a protected filtration system that keeps all residual tank contaminants to levels below the PEL established by OSHA (less than 30 ug/m3 or 50 ug/dl).
Provide a disposal service of spent filters that are at no cost to the customer without involvement from the State Environmental Office.
Ambient air filtration system that provides HEPA (High Efficiency Particulate Air) filtration of the operating environment providing at least 4 air changes per hour ventilation.
External, portable power source is provided that includes all wiring, terminals, circuits, 100-amp service panel and GFCI (Ground Fault Circuit interrupter) circuitry and 20% available power above system requirements. Power is provided by a diesel, gas or LP powered generator providing 110/ 220 ac/ 2 phased power.
will include 25 wire cleaning baskets capable of submersion into solution tanks, fitted with hanging brackets to allow liquids to drain into tank.
4 disassembly and assembly workstations (portable, foldable, storable tables). System and components will have a 5-year warranty and include on-site training for 2 days for operators and stakeholders.
Self-retracting 12x14 ft Awning attached to outside of trailer.
Compressed air throughout trailer.
Bumper pulled not longer than 29ft long trailer (excluding hitch), 8.5 foot wide, no taller than
13.6 ft tall with 2 5/16 ball and adjustable receiver that allows 6 inches for level pull and sway bar stabilization system.
Wiring harness able to adopt to 7 ways round coupler and or 4-way flat plug with locking mechanism.
Two dual torsion axles rated at minimum of 6,000lbs each.
Electric adjusting braking systems.
Exterior vinyl wrap custom to the MTARNG.
LED Lighting on exterior trailer will meet DOT requirements.
Interior floor needs to be rhino lined type and non-slip surface.
Stabilizing jacks on all four corners.
Self-lowering and raising ramp on the rear of trailer and two outward man doors mounted on the front of trailer at opposite sides with self-retracting steps.