This document contains drawings related to a federal contract opportunity for renovations to the Cody Service Center office. The drawings include a location map, floor plans, power plans, lighting plans, and HVAC plans for the office remodel project. They provide architectural, electrical, and HVAC details for the renovation of the Cody Service Center located in Cody, Wyoming as part of solicitation number 89503222BWA000053 for the Boysen Peak Generator Site and Cody Office Remodel opportunity with the Department of Energy's Western Area Power Administration. The contractor shall review all drawings and notify the agency of any errors or omissions.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment D
Cody Service Center Drawings
89503222BWA000053
21 May 2022
CODY SERVICE CENTER OFFICE REMODEL
DIVISION 15 - DRAWINGS
A. GENERAL:
CONSTRUCTION DRAWINGS: Construction drawings are the specification drawings and any additional drawings required for use in construction. The construction drawings will be issued after contract award and may include amendment changes and other details, which make the drawings suitable to use for construction purposes.
PROJECT DRAWINGS: Project drawings included herein are reduced reproductions and are not to scale. Some project drawings show details of fabrication and other information not a part of the work. Disregard information and details, which are not applicable.
STANDARD DRAWINGS: Where details shown on standard drawings included herein differ from construction or project drawings or text, the details of construction or project drawings or text shall govern. A complete set of standard drawings are available at https://www.wapa.gov/DoingBusiness/SellingToWestern/Pages/what-western-buys.aspx.
INFORMATIONAL DRAWINGS: Some project drawings have the words “FOR INFORMATION ONLY” appearing above the title block. These drawings show some information, which may be required for bidding purposes. These drawings do not show items to be furnished or work to be performed.
EXISTING INSTALLATION DRAWINGS: Some project drawings have the words “EXISTING INSTALLATION” appearing above the title block. These drawings show the existing installations prior to modifications and may show some new work to be performed.
REFERENCE DRAWINGS: Reference drawings referred to on project drawings and not included herein, are not necessary for bidding purposes.
CONTRACTOR'S RESPONSIBILITY: Check all drawings and advise Western of any errors or omissions.
B. LIST OF DRAWINGS:
LOCATION MAP:
1. CDY 0017 – LOCATION AND VICINITY MAP (FIO)
ARCHITECTURAL:
2. CDY 300 – FLOOR PLAN
3. CDY 300 – REV A - FLOOR PLAN
ELECTRICAL:
1. CDY 330 – POWER PLAN
2. CDY 330 – REV A - POWER PLAN
3. CDY 331 – LIGHTING PLAN
4. CDY 331 – REV A - LIGHTING PLAN
HVAC:
1. CDY 340 – HVAC PLAN
2. CDY 340– REV A - HVAC PLAN