21Q0207_Attachment 1- Technical Specifications.pdf

PDF 60 KB Posted

Attached to
Power Pack- Brand Name Mandatory: MAXPRO TECHNOLOGIES Federal contract opportunity
Solicitation number
N3904021Q0207
Issued by
Department of the Navy Naval Sea Systems Command

View the file

Other files for this federal contract opportunity

Other files attached to Power Pack- Brand Name Mandatory: MAXPRO TECHNOLOGIES, newest first.
File Type Posted
21Q0207_RFQ Request for Quote Sheet_25May21.pdf PDF
21Q0207_Attachment 2- BNM_redacted.pdf PDF
N3904021Q0207_Combined Synopsis Sol_25May21.pdf PDF
21Q0207_Attachment 2_LSJ-SS_KOsigned_Redacted.pdf PDF
21Q0207_Combined Synopsis Solicitation.pdf PDF
21Q0207_RFQ Request for Quote Sheet_100521.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REQ DOC NO. - 1053V006 REV 1 ATTACHMENT ____1____

CONTINUATION SHEET CONTRACT NO. - _______________ PAGE _1__ OF _2__

NAME OF OFFER OR/CONTRACTOR

POWER PACK 2 EA

C. DESCRIPTION/SPECIFICATIONS

C.1 POWER PACK: MAXPRO TECHNOLOGIES MODEL MTPP15-W-PP111-

HL-N-G-2V-RD.

C.2 THE POWER PACK IS DESIGNED FOR WATER SERVICE AND INCLUDE

THE FOLLOWING:

C.2.1 PP111S-HL AIR DRIVEN PUMP WITH HAND LEVER, 1:130 RATIO,

POLYURETHANE SEALS & BUNA-N O-RINGS

C.2.2 DRIVE AIR INLET FILTER

C.2.3 PANEL MOUNTED AIR REGULATOR AND 2.5 INCH DIA, 0 – 160

PSIG PRESSURE GAUGE

C.2.4 STAINLESS STEEL PORTABLE BASE PLATE WITH HANDLE AND

VERTICAL CONTROL PANEL. THE SYSTEM FRAME WILL INCLUDE

STORAGE FOR THE PUMP DRIVE HANDLE.

C.2.5 HEISE 6 INCH CM PRECISION PRESSURE GAUGE, 0 – 15,000 PSI

WITH 9/16”-18 FEMALE BACK CONNECTION. PANEL MOUNT, SLOKD

FRONT, BLOW OUT BACK, WITH HIGH AND LOW PRESSURE LIMIT

STOP AND SLOTTER LINK TO PROTECT MOVEMENT. MIRROR BAND

DIAL, + 0.1% FULL SCALE ACCURACY, WITH SIGNED CERTIFICATE OF

CONFORMANCE.

C.2.6 2500 – 25,000 PSIG ADJUSTABLE RELIEF VALVE, MOUNTED

VERTICALLY.

ITEM # SUPPLIES/SERVICES QTY U/I

C.2.7 35,000 PSIG RATED MAXIMATORTM BRAND ISOLATION & VENT

VALVES

C.2.8 65,000 PSIG RATED MAXIMATORTM BRAND FITTINGS & TUBING

FOR THE HIGH PRESSURE PLUMBING.

C.3 THE SYSTEM IS DESIGNED FOR 15,000 PSIG MAXIMUM OUTLET

PRESSURE AND WILL HAVE THE FOLLOWING CONNECTIONS

C.3.1 DRIVE AIR INLET: HANSEN 3-L15 PLUG END

C.3.2 WATER INLET: HANSEN LL2-K6-192 PLUG END

C.3.3 HIGH PRESSURE OUTLET: SNAP TITE S77C4-SF375CXV SOCKET

END

C.3.4 VENT OUTLET: HANSEN LL2-H6-SL-192 SOCKET END.

C.4 NO OTHER UTILITIES ARE REQUIRED. UNIT CAN BE OPERATED WITH

EITHER COMPRESSED AIR DRIVE, OR MANUAL HAND LEVER

OPERATION. NO CHANGES ARE REQUIRED TO SWITCH BETWEEN

THE TWO MODES OF OPERATION. ALL COMPONENTS WILL BE PRE-

PLUMBED AND MOUNTED ON THE HANDLE AND BASE PLATE, AND

TESTED PRIOR TO SHIPMENT. TO ACCOMMODATE ALL THE NEW

PANEL MOUNTED EQUIPMENT, THE ANTICIPATED SYSTEM

DIMENSIONS WILL BE 20” W X 10” D X16” H.