FLOW CONTROL SYSTEM REDESIGN

1. INTRODUCTION

Naval Surface Warfare Center (NSWC), Corona Division, Measurement Science Department, Code MS35, requires the acquisition of quantity 27 each; P/N 71DE System Redesigned flow control system for Novec 71DE in 1 Gallon Glass Bottle and quantity 27 each, P/N 7100 System Redesigned flow control system for Novec 7100 in 1 Gallon Glass Bottle.

2. BACKGROUND

Measurement Science Department Corona has a requirement to provide Test and Measurement Diagnostic Equipment (TMDE) and/or associated components for the Calibration Standards Program to support the Navy Calibration Labs with calibration standard test equipment.

Equipment procured on this request is going to support calibration standard program for calibration support of solvent removal for Oxygen gages. Navy Test measurement and Diagnostic Equipment (TMDE) assets associated include the emergency Oxygen recompression systems, Oxygen concentrator systems, life support Oxygen converter systems, aircraft liquid Oxygen systems. These standards will be shipped to several Navy Calibration Labs.

This procurement is to modify existing contract N6426720P0285.The contract did not require the parts to be Oxygen-clean, which is a requirement for these parts. This modification would change parts for other readily available parts and will include the Oxygen-clean requirement. In order to meet the requirements, the equipment listed below is needed.

PURCHASE DESCRIPTION

2 | 3

Equipment is to be new. Refurbished equipment is not acceptable Shipping is to be included in cost.

3. REQUIREMENTS

DESCRIPTION QTY P/N:

Redesigned flow control system for

Novec 71DE in 1 Gallon Glass Bottle 27 EA 71DE System

- Swagelok - Stainless Ball valve 27 SS‐44F6

- Cleaning by Swagelok 27 SC11

- Swagelok 45 degree angle tube fitting 27 SS‐400‐5‐4

- Cleaning by Swagelok 27 SC11

- Swagelok PFA 1/4 inch hosing 50 feet 01 SS-PFA-.25

- GT Body barb assembly 27 TBD

- Low Pressure bushing 3/8" Male x 1/4 Female 27 4443K163

- ASTM 93 C cleaning by Astropak 27 N/A

- Fully threaded, 1/4 NPT, 7/8" long pipe nipple 27 4830K131

- ASTM 93 C cleaning by Astropak 27 N/A

- Cleaning to ASTM 93 C by Astropak 27 91s6‐1/4

Redesigned flow control system for Novec 7100 in 1 Gallon Glass Bottle 27 EA 7100 System

- Swagelok Stainless Ball valve 27 SS‐44F6

- cleaning by Swagelok 27 SC11

- Swagelok 45 degree angle tube fitting 27 SS‐400‐5‐4

- Cleaning by Swagelok 27 SC11

- Swagelok PFA 1/4 inch hosing 50 feet 01 SS-PFA-.25

- GT Body barb assembly 27 TBD

- Low Pressure bushing 3/8" Male x 1/4 Female 27 4443K163

- ASTM 93 C cleaning by Astropak 27 N/A

- Fully threaded, 1/4 NPT, 7/8" long pipe nipple 27 4830K131

- ASTM 93 C cleaning by Astropak 27 N/A

- Cleaning to ASTM 93 C by Astropak 27 91s6‐1/4

ADDITIONAL INFORMATION

A. PERIOD OF PERFORMANCE / REQUIRED DELIVERY DATES

B. PLACE OF PERFORMANCE

N/A

60 Days after Contract Award

3 | 3

C. SHIPPING ADDRESS

NSWC Corona Division

UIC: N64267

1999 Fourth Street Norco, CA 92860