About this file
This document is a Supplement to AFLC Form 761 dated 15NOV2016 for a solenoid valve (National Stock Number 4810-00-782-7732HS, Part Number 2-43909-1) with specific qualification requirements. The form details stringent qualification criteria for manufacturers, requiring that only actual manufacturers who have successfully completed all testing required by the original design company can be considered approved sources. The qualification requirements are set forth in the OC-ALC Source Approval Information Booklet, with two primary qualification paths: (1) manufacturers who completed original design testing, or (2) manufacturers who have completed testing on items determined by the government to be similar in complexity and criticality. The document provides both pre-19 OCT 84 and post-19 OCT 84 qualification frameworks, emphasizing the need to maintain high quality and maximum operational safety for this critical component.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| QR_NIIN_007204725.pdf | ||
| 3909054_ATTACH.pdf | ||
| SPRTA1-25-Q-0450.pdf | ||
| 4058340_PKGRQMT_REPORT.pdf | ||
| 4059859_TRNSPDATA_REPORT.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SUPPLEMENT TO AFLC FORM 761
DATE
NOUN NATIONAL STOCK NUMBER PART NUMBER
Only the checked statement applies to this NSN.
QUALIFICATIONS REQUIREMENTS PRIOR TO 19 OCT 84
Section F.1
This item qualifies under FAR 9.206-1(a)(2) and the requirements of FAR 9.202(a) are not applicable.
Prequalification of sources is essential to maintain high quality and maximum operational safety.
Section F.2
(a) Qualification requirements are set forth in OC-ALC Source Approval Information Booklet. Due to the complexity and criticality of this part, only actual manufacturers that have successfully completed all testing required by the original company responsible for the design, can be considered approved sources for this item.
(b) Qualification requirements are set forth in OC-ALC Source Approval Information Booklet. Due to the complexity and criticality of this part, only actual manufacturers that have successfully completed all testing required by the original company responsible for the design, or manufacturers that have successfully completed all testing on items determined by the government to be similar in complexity and criticality, can be considered approved sources for this item.
(c) Qualification requirements are set forth in OC-ALC Source Approval Information Booklet.
Category III capability is permissible.
Section F.3
The provisions of FAR 9.206-1 and -2, as supplemented, apply. In accordance with AFMCFARS, 1 July 97, Part 5309.206-1(e)(1), Notes A and B apply. Qualification requirements were established prior to 19 Oct 84.
QUALIFICATION REQUIREMENTS AFTER 19 OCT 84
Justification for Qualification Requirement (JQR) is required.
Section F.1
Prequalification of sources is essential to maintain high quality and maximum operational safety. The requirements of FAR 9.202(a) apply.
Section F.2
(a) Qualification requirements are set forth in OC-ALC Source Approval Information Booklet. Due to the complexity and criticality of this part, only actual manufacturers that have successfully completed all testing required by the original company responsible for the design, can be considered approved sources for this item.
(b) Qualification requirements are set forth in OC-ALC Source Approval Information Booklet. Due to the complexity and criticality of this part, only actual manufacturers that have successfully completed all testing required by the original company responsible for the design, or manufacturers that have successfully completed all testing on items determined by the government to be similar in complexity and criticality, can be considered approved sources for this item.
Section F.3
The provisions of FAR 9.206-1 and -2, as supplemented, apply. In accordance with AFMCFARS, 1 July 97, Part 5309.206-1(e)(1), Notes A and D apply. Qualification requirements were established after 19 Oct 84.
EVALUATING ENGINEER/TECHNICIAN (Signature) SYMBOL EXTENSION
OC-ALC Form O-367, JUN 01 (TI) http://www.tinker.af.mil/shared/media/document/AFD-070109-194.doc http://www.tinker.af.mil/shared/media/document/AFD-070109-194.doc http://www.tinker.af.mil/shared/media/document/AFD-070109-194.doc http://www.tinker.af.mil/shared/media/document/AFD-070109-194.doc http://www.tinker.af.mil/shared/media/document/AFD-070109-194.doc
| DATE: 15NOV2016 | |
| NOUN: VALVE, SOLENOID | |
| NATIONAL STOCK NUMBER: 4810-00-782-7732HS | |
| PART NUMBER: 2-43909-1 | |
| Radio Button1: No | |
| 2016-11-15T09:29:50-0600 | |
| JENKINS.DENA.L.1385757421 |
| SYMBOL: 423SCMS/GUEA |
| EXTENSION: 852-9977 |