20260818_WildlifeGuzzler_PR.pdf
PDF 254 KB Posted
- Attached to
- 2026 WILDLIFE GUZZELERS Federal contract opportunity
- Solicitation number
- 140L2626Q0061
About this file
This is a Statement of Work (SOW) and Specifications document from the Bureau of Land Management Twin Falls District Office – Shoshone Field Office for the procurement of wildlife guzzlers, rain collection systems, and associated building materials for the Laidlaw area. The deliverables must be shipped to 400 West F Street, Shoshone, Idaho 83352.
The requirement includes three 650-gallon capacity wildlife guzzlers with dome tops, rain catchment systems, and built-in escape ramps. Each guzzler must weigh 290 lbs, measure 118" x 64" x 22" (deck height), feature a dome roof surface area of 53 square feet optimized for rain collection (33 gallons per 1" of rain), and include a 28-degree escape ramp slope. The guzzlers must be constructed of Linear Low Density Polyethylene (LLDPE) with UV inhibitor, sand granite color, and include internal column and aluminum cross-bar support, bolt-down lid with four 3/8" bolts, 1" drain and line-in fittings, 1" winter water level drain plug, 2" bulkhead fitting, and 10" inspection hatch. The rain collector systems require 50 linear feet of aluminum guttering, 12 sheets of galvanized corrugated 10-foot metal, 24 treated support posts (5 feet tall), 24 2x4x10 structural boards, plus specified quantities of nails, screws, bolts, washers, and hardware. The fence exclosure specifications for three replacements include 235 metal studded T posts (6 feet), 13 rolls of barbed wire (2-strand), 10 rolls of smooth twisted wire, 12 heavy-duty corner H-brace assemblies with specified steel pipe dimensions, 100 wire stays, and 1,000 metal universal studded t-post fastening clips.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140L2626Q0061.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Bureau of Land Management
Twin Falls District Office – Shoshone Field Office
Wildlife Guzzlers- Specifications/ Statement of Work
Background
The Bureau of Land Management (BLM) Twin Falls District Office (TFDO) - Shoshone Field Office (SFO), seeks to purchase wildlife guzzlers, rain collection systems and associated building materials for replacement and use in Laidlaw are of Shoshone Field Office, see delivery street address, 400 West F St., Shoshone, ID 83352
The Wildlife guzzlers shall meet the minimum required specifications:
Dimensional drawing and details showing required rain catchment system and wildlife guzzlers with escape ramp.
GUZZLER SPECIFICATIONS: 3 each – 650 gallon capacity, dome top, rain catchment Wildlife Guzzler with escape ramp
• Capacity 650 Gallons
• Weight 290 Lbs
• Dimensions 118" x 64" x 22" (deck height)
• Dome roof surface area of 53 sq ft. (33 Gallons per 1" rain) to optimize rain collection ability.
• Lid covers 80%. Exposed water area is 20% (pertains to evaporation)
• Escape ramp slope 28 degrees, Built-In.
• Large drinking area accommodates deer and elk racks
• Above-ground or in-ground installation
• Durable polyethylene plastic construction, Linear Low Density Polyethene (LLDPE) with UV inhibitor
• Internal column for extra lid strength
• Includes 1” Drain Fitting and 1” Line-In Fitting
• Bolt-down lid, held into place with four, 3/8” bolts
• Includes a 1”, “Winter Water Level” drain plug on side-wall to easily lower water level in locations with hard winter freezes
• 2" bulkhead fitting for fast manual filling
• 10” Inspection hatch
• Color Sand Granite o Internal Column and Cross-Bar Support Internal column ensures dome support from the weight of snow and curious animals, such as bears, when walking on the lid.
o The aluminum cross-bar and frame give extra reinforcement to the side walls and water pressure
RAIN COLLECTOR SYSTEM SPECIFICATIONS: for 3 wildlife guzzler systems
• Q 50 linear ft of Aluminum guttering
• Q 12 sheets of galvanized corrugated 10 ft metal
• Q 24 of 5 ft tall, treated support posts
• Q 24 2x4x10 structural boards
• Q 500 count 4 inch galvanized construction nails
• Q 350 count Self tapping Tin screws #8 x ½ inch
• Q 30 count 1/2-inch x 8 inch hot dipped or ceramic tip bolts
• Q 30 hex nuts
• Q 30 count Split Lock Washers
• Q 60 count Flat Washers
FENCE EXCLOSURE SPECIFICATIONS: for 3 replacements of exclosures
• Q 235 count of 6 ft metal studded T posts
• Q 13 Barbed Wire (2 strand) rolls
• Q 10 Smooth Wire (twisted) rolls
• Q 12 heavy duty 3 posts corner H brace assemblies o Large pipe – Q 36; 2-7/8” OD (or 3-1/2” OD) Sch 40 steel pipe x 7’- 8’ length o Small pipe – Q 24; 2-3/8” OD Sch 40 steel pip x 6’- 8’ length
• Q 100 count (1 bundle) of Wire Stays
• Q 1000 count Metal universal studded t-post fastening clips
File details come from the government source that posted it. Updated .