2026.05.12_Fire_Station_No._1_Wind_Mitigation.pdf
PDF 27 MB Posted
- Attached to
- Fire Station No. 1 Wind Retrofit Project
- Solicitation number
- 26-009
- Issued by
- Santa Rosa County, Florida
About this file
Fire Station No. 1 Wind Mitigation Project – Design and Specifications Document
This is a comprehensive set of design and construction drawings for the City of Dania Beach Fire-Rescue Station No. 1 Wind Mitigation project located at 116 West Dania Beach Blvd., Dania Beach, Florida. The project scope includes structural retrofits and hurricane-resistant modifications to comply with current building standards. Primary work items include replacement of identified doors with new Miami-Dade County-approved impact doors, construction of a new concrete pad to support an electric generator, re-roofing of all roof areas, installation of new access ladders and tie-downs around existing mechanical units, masonry wall infills to close openings, new electrical infrastructure including generator connections and panel schedules, and comprehensive roofing system replacement with new drainage provisions. The design documents include cover sheets, signature sheets, legends, civil plans with site details, electrical notes and schematics, structural plans with first floor layouts, wind pressure analysis on components and building elevations, generator slab and foundation details, roof plans showing demolition and new construction, roofing details with overflow scupper specifications, access ladder and roof penetration details, and existing roofing assembly documentation. The project was prepared by multiple engineering firms: Lakdas/Yohalem Engineering, Inc. (structural and civil); Calvin, Giordano Associates, Inc. (additional structural support); and consulting engineers for electrical systems. The bid set is dated April 28, 2026, with elevations referenced to NAVD 88 datum.
The project design incorporates wind design standards per ASCE 7-22 and Florida Building Code 2023 (eighth edition) for a 187 mph wind speed exposure category IV. Construction specifications include detailed requirements for concrete (4000 psi for structural elements, 3000 psi for other work), masonry using Type S or M mortar per ASTM C270, and built-up roofing with 4-ply torch-down systems over R-19 tapered insulation. Professional engineers responsible for plans include Jenna Martinetti (P.E. #69035 and #69305), Jorge R. Cervantes (P.E. #45832), and Lakdas Nanayakkara (P.E. #037590). The bid set documentation emphasizes that all contractors must conduct site visits prior to bidding to verify existing conditions, coordinate with city staff, and verify field dimensions prior to fabrication of impact doors, generator pads, masonry work, and roofing systems. No specific contract award value, budget allocation, or project completion timeline is identified in the design documents; these would be specified in the corresponding bid documents and contract terms issued by the City of Dania Beach.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PR
OJ
EC
T
No : 2
1-
.1
DANIA BEACH, FL.
NOTES:
LEGAL DESCRIPTION:
116 WEST DANIA BEACH BLVD.
JENNA MARTINETTI, STATE OF FLORIDA, PROFESSIONAL ENGINEER, LICENSE NO. 69035.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY JENNA MARTINETTI, P.E. ON THE
DATE INDICATED HERE.
PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
N
S
W E
BENCHMARK:
PROJECT
LOCATION
FIRE STATION NO. 1 WIND MITIGATION
Scale: 1" = 300'
LOCATION MAP
CITY LOGO HERE
NUMBER
PERMITCGA
INITIALSSUBMITTED
DATEPERMITTING AGENCIES DATE
APPROVED
CURRENT REV No.: ---- - ----
SHEET:
DATE:NONO DATE REVISION BY REVISIONDATE BY 01/06/2026
G0
R
KNOW WHAT'S BELOW
AL W A Y S C A L L 8 1 1
B E F O R E Y O U D I G
It's fast. It's free. It's the law.
www.callsunshine.com
BID SET
NOT FOR CONSTRUCTION
ELEVATIONS ARE IN NAVD 88
CITY OFFICIALSCITY OFFICIALS
MAYOR: JOYCE L. DAVIS
VICE-MAYOR: MARCO A. SALVINO, SR.
COMMISSIONERS: LORI LEWELLEN
LUIS RIMOLI
A. J. RYAN IV
CITY MANAGER: ANA M. GARCIA
S.
F
ED
ER
AL
H
W Y
DANIA BEACH BLVD.
N W
ST
A
VE
N W rd
A
VE
HILL ST.
Sheet List Table Sheet Number Sheet Title
G0 COVER SHEET
G1 SIGNATURE SHEET
G2 LEGEND, ABBREVIATIONS AND GENERAL NOTES
C1 PROPOSED SITE PLAN
C2 CIVIL DETAILS
E1 ELECTRICAL NOTES
E2 ELECTRICAL SITE PLAN
E3 ELECTRICAL RISERS
E4 ELECTRICAL PANEL SCHEDULES
E5 GENERATOR SPECS AND ELECTRICAL DETAILS
E6 GENERATOR DETAILS
CV INDEX SHEET
S-1 FIRST FLOOR PLAN
S-2 WIND PRESSURES ON COMPONENTS
S-3 GENERATOR SLAB & NEW WALL INFILL
S-4 ROOF PLAN
S-5 DEMOLITION PLAN
S-6 NEW ROOF PLAN
S-7 ROOFING DETAILS
S-8 ROOFING DETAILS
S-9 ACCESS LADDER AND ROOF PENETRATION
S-10 ROOF DESIGN WIND PRESSURES AND GENERAL NOTES
S-11 EXISTING ROOFING
P1 GAS DEMO SITE PLAN
STIRLING ROAD
05/01/2026
MULTICORELINK:2143131-G-SIGN-24x36 MULTICORELINK:2143131-G-SIGN-24x36
MULTICORELINK:2143131-G-LGND-ABBR-G2
MULTICORELINK:2143131-G-LGND-ABBR-G2
MULTICORELINK:2143131-C-PLAN-C1
MULTICORELINK:2143131-C-PLAN-C1
MULTICORELINK:2143131-C-DTLS-C2
MULTICORELINK:2143131-C-DTLS-C2
MULTICORELINK:2143131-E-NOTE-E1
MULTICORELINK:2143131-E-NOTE-E1
MULTICORELINK:2143131-E-PLAN-E2
MULTICORELINK:2143131-E-PLAN-E2
MULTICORELINK:2143131-E-DTLS-E3
MULTICORELINK:2143131-E-DTLS-E3
MULTICORELINK:2143131-E-DTLS-E4
MULTICORELINK:2143131-E-DTLS-E4
MULTICORELINK:S-PLAN-SHET-SET-CV
MULTICORELINK:S-PLAN-SHET-SET-CV
MULTICORELINK:S-PLAN-SHET-SET-S-1
MULTICORELINK:S-PLAN-SHET-SET-S-1
MULTICORELINK:S-PLAN-SHET-SET-S-2
MULTICORELINK:S-PLAN-SHET-SET-S-2
MULTICORELINK:S-PLAN-SHET-SET-S-3
MULTICORELINK:S-PLAN-SHET-SET-S-3
MULTICORELINK:S-PLAN-SHET-SET-S-4
MULTICORELINK:S-PLAN-SHET-SET-S-4
MULTICORELINK:S-PLAN-SHET-SET-S-5
MULTICORELINK:S-PLAN-SHET-SET-S-5
MULTICORELINK:S-PLAN-SHET-SET-S-6
MULTICORELINK:S-PLAN-SHET-SET-S-6
MULTICORELINK:S-PLAN-SHET-SET-S-7
MULTICORELINK:S-PLAN-SHET-SET-S-7
MULTICORELINK:S-PLAN-SHET-SET-S-8
MULTICORELINK:S-PLAN-SHET-SET-S-8
MULTICORELINK:S-PLAN-SHET-SET-S-9
MULTICORELINK:S-PLAN-SHET-SET-S-9
MULTICORELINK:S-PLAN-SHET-SET-S-10
MULTICORELINK:S-PLAN-SHET-SET-S-10
MULTICORELINK:S-PLAN-SHET-SET-S-11
MULTICORELINK:S-PLAN-SHET-SET-S-11
MULTICORELINK:P1 GAS DEMO SITE PLAN-P1 GAS DEMO SITE PLAN
MULTICORELINK:P1 GAS DEMO SITE PLAN-P1 GAS DEMO SITE PLAN
SIGNATURE SHEET
BID SET
NOT FOR CONSTRUCTION
ELEVATIONS ARE IN NAVD 88
FIRE STATION NO. 1 WIND MITIGATION
116 WEST DANIA BEACH BLVD.
DANIA BEACH, FL.
NONO DATE REVISION BY REVISIONDATE BY
SCALE
PROJECT No
SHEET
DATE:
R
KNOW WHAT'S BELOW
A L W A Y S C A L L 8 1 1 B E F O R E Y O U D I G
It's fast. It's free. It's the law.
www.callsunshine.com
05/01/2026 21-4313.1
AS SHOWN G1
ELECTRICAL AND GAS PLANS
THE ABOVE NAMED PROFESSIONAL ENGINEER SHALL BE RESPONSIBLE FOR THE
FOLLOWING SHEETS IN ACCORDANCE WITH THE RULE 61G15-23.004, F.A.C.
JORGE R. CERVANTES, STATE OF FLORIDA,
PROFESSIONAL ENGINEER, LICENSE NO. 45832.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED
BY JORGE R. CERVANTES, P.E. ON THE DATE
INDICATED HERE.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC
COPIES.
J o rge R. CervantesLICENSE
NO. 45832
PRO
FESSIONA L ENGIN
EE
R
FLO R IDA
STATE OF
CALVIN, GIORDANO ASSOCIATES, INC.
1800 ELLER DRIVE, SUITE 600
FORT LAUDERDALE, FLORIDA 33316
954-921-7781
CIVIL PLANS
THE ABOVE NAMED PROFESSIONAL ENGINEER SHALL BE RESPONSIBLE FOR THE
FOLLOWING SHEETS IN ACCORDANCE WITH THE RULE 61G15-23.004, F.A.C.
Sheet List Table Sheet Number Sheet Title
G1 SIGNATURE SHEET
E1 ELECTRICAL NOTES
E2 ELECTRICAL SITE PLAN
E3 ELECTRICAL RISERS
E4 ELECTRICAL PANEL SCHEDULES
E5 GENERATOR SPECS AND ELECTRICAL DETAILS
E6 GENERATOR DETAILS
P1 GAS DEMO SITE PLAN
Sheet List Table Sheet Number Sheet Title
G0 COVER SHEET
G1 SIGNATURE SHEET
G2 LEGEND, ABBREVIATIONS AND GENERAL NOTES
C1 PROPOSED SITE PLAN
C2 CIVIL DETAILS
LAKDAS/YOHALEM ENGINEERING, INC.
2211 NE 54th ST.
FORT LAUDERDALE, FLORIDA 33308
954-771-0630
THE ABOVE NAMED PROFESSIONAL ENGINEER SHALL BE RESPONSIBLE FOR THE
FOLLOWING SHEETS IN ACCORDANCE WITH THE RULE 61G15-23.004, F.A.C.
LAKDAS NANAYAKKARA, STATE OF FLORIDA,
PROFESSIONAL ENGINEER, LICENSE NO. 037590.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND
SEALED BY LAKDAS NANAYAKKARA, P.E. ON THE
DATE INDICATED HERE.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE MUST BE VERIFIED ON ANY
ELECTRONIC COPIES.
CALVIN, GIORDANO ASSOCIATES, INC.
1800 ELLER DRIVE, SUITE 600
FORT LAUDERDALE, FLORIDA 33316
954-921-7781
STRUCTURAL PLANS
Sheet List Table Sheet Number Sheet Title
G1 SIGNATURE SHEET
CV INDEX SHEET
S-1 FIRST FLOOR PLAN
S-2 WIND PRESSURES ON COMPONENTS
S-3 GENERATOR SLAB & NEW WALL INFILL
S-4 ROOF PLAN
S-5 DEMOLITION PLAN
S-6 NEW ROOF PLAN
S-7 ROOFING DETAILS
S-8 ROOFING DETAILS
S-9 ACCESS LADDER AND ROOF PENETRATION
S-10 ROOF DESIGN WIND PRESSURES AND GENERAL NOTES
S-11 EXISTING ROOFING
JENNA MARTINETTI, STATE OF FLORIDA,
PROFESSIONAL ENGINEER, LICENSE NO. 69305.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED
BY JENNA MARTINETTI, P.E. ON THE DATE INDICATED
HERE.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC
COPIES.
J e nna MartinettiLICENSE
NO. 69305
PRO
FESSIONA L ENGIN
EE
R
FLO R IDA
STATE OF
LICENSE
ABBREVIATION LEGEND LINE TYPE LEGEND
HATCHING LEGEND
PROPOSED SYMBOL LEGEND EXISTING SYMBOL LEGEND
NONO DATE REVISION BY REVISIONDATE BY
SCALE
PROJECT No
SHEET
DATE:
JENNA MARTINETTI, STATE OF FLORIDA, PROFESSIONAL ENGINEER, LICENSE NO. 69035.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY JENNA MARTINETTI, P.E. ON THE
DATE INDICATED HERE.
PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
R
KNOW WHAT'S BELOW
A L W A Y S C A L L 8 1 1 B E F O R E Y O U D I G
It's fast. It's free. It's the law.
www.callsunshine.com
01/06/2025 21-4313.1
AS SHOWN G2LEGEND, ABBREVIATIONS AND
GENERAL NOTES
FIRE STATION NO. 1 WIND MITIGATION
116 WEST DANIA BEACH BLVD.
DANIA BEACH, FL.
BID SET
NOT FOR CONSTRUCTION
ELEVATIONS ARE IN NAVD 88
05/01/2026
PROPOSED SITE PLAN
NOT FOR CONSTRUCTION
ELEVATIONS ARE IN NAVD 88
FIRE STATION NO. 1 WIND MITIGATION
116 WEST DANIA BEACH BLVD.
DANIA BEACH, FL.
NONO DATE REVISION BY REVISIONDATE BY
SCALE
PROJECT No
SHEET
DATE:
JENNA MARTINETTI, STATE OF FLORIDA, PROFESSIONAL ENGINEER, LICENSE NO. 69035.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY JENNA MARTINETTI, P.E. ON THE
DATE INDICATED HERE.
PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
R
KNOW WHAT'S BELOW
A L W A Y S C A L L 8 1 1 B E F O R E Y O U D I G
It's fast. It's free. It's the law.
www.callsunshine.com
05/01/2026 21-4313.1
AS SHOWN C1
NOTES:
LEGEND
PLAN
ELEVATION
SECTION
SIDEWALK JOINTS
SIDEWALK JOINTS
CONCRETE SIDEWALK
SCALE: N.T.S. CURRENT
NOTES:
TYPICAL RESTORATION OF
LESS THAN 1/2 LANE
OF ROCK BASE
TYPICAL RESTORATION OF
MORE THAN 1/2 LANE
OF ROCK BASE
TRENCH WITH PAVEMENT RESTORATION PERPENDICULAR
TRENCH WITH PAVEMENT RESTORATION LONGITUDINAL
PAVEMENT RESTORATION
SCALE: N.T.S.
PIPE TRENCH IN SATISFACTORY SOILS
SCALE: N.T.S.
CIVIL DETAILS
BID SET
NOT FOR CONSTRUCTION
ELEVATIONS ARE IN NAVD 88
FIRE STATION NO. 1 WIND MITIGATION
116 WEST DANIA BEACH BLVD.
DANIA BEACH, FL.
NONO DATE REVISION BY REVISIONDATE BY
SCALE
PROJECT No
SHEET
DATE:
JENNA MARTINETTI, STATE OF FLORIDA, PROFESSIONAL ENGINEER, LICENSE NO. 69035.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY JENNA MARTINETTI, P.E. ON THE
DATE INDICATED HERE.
PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
R
KNOW WHAT'S BELOW
A L W A Y S C A L L 8 1 1 B E F O R E Y O U D I G
It's fast. It's free. It's the law.
www.callsunshine.com
05/01/2026 21-4313.1
AS SHOWN C2
ELECTRICAL NOTES
NOT FOR CONSTRUCTION
ELEVATIONS ARE IN NAVD 88
FIRE STATION NO. 1 WIND MITIGATION
116 WEST DANIA BEACH BLVD.
DANIA BEACH, FL.
NONO DATE REVISION BY REVISIONDATE BY
SCALE
PROJECT No
SHEET
DATE:
JORGE R. CERVANTES, STATE OF FLORIDA, PROFESSIONAL ENGINEER, LICENSE NO. 45832.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY JORGE R. CERVANTES, P.E. ON
THE DATE INDICATED HERE.
PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
R
KNOW WHAT'S BELOW
A L W A Y S C A L L 8 1 1 B E F O R E Y O U D I G
It's fast. It's free. It's the law.
www.callsunshine.com
05/01/2026 21-4313.1
AS SHOWN E1
ELECTRICAL SITE PLAN
NOT FOR CONSTRUCTION
ELEVATIONS ARE IN NAVD 88
FIRE STATION NO. 1 WIND MITIGATION
116 WEST DANIA BEACH BLVD.
DANIA BEACH, FL.
NONO DATE REVISION BY REVISIONDATE BY
SCALE
PROJECT No
SHEET
DATE:
JORGE R. CERVANTES, STATE OF FLORIDA, PROFESSIONAL ENGINEER, LICENSE NO. 45832.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY JORGE R. CERVANTES, P.E. ON
THE DATE INDICATED HERE.
PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
R
KNOW WHAT'S BELOW
A L W A Y S C A L L 8 1 1 B E F O R E Y O U D I G
It's fast. It's free. It's the law.
www.callsunshine.com
05/01/2026 21-4313.1
AS SHOWN E2
NOTES:
ELECTRICAL RISERS
NOT FOR CONSTRUCTION
ELEVATIONS ARE IN NAVD 88
FIRE STATION NO. 1 WIND MITIGATION
116 WEST DANIA BEACH BLVD.
DANIA BEACH, FL.
NONO DATE REVISION BY REVISIONDATE BY
SCALE
PROJECT No
SHEET
DATE:
JORGE R. CERVANTES, STATE OF FLORIDA, PROFESSIONAL ENGINEER, LICENSE NO. 45832.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY JORGE R. CERVANTES, P.E. ON
THE DATE INDICATED HERE.
PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
R
KNOW WHAT'S BELOW
A L W A Y S C A L L 8 1 1 B E F O R E Y O U D I G
It's fast. It's free. It's the law.
www.callsunshine.com
05/01/2026 21-4313.1
AS SHOWN E3
DEMOLITION ELECTRICAL RISER
SCALE: N.T.S.
PROPOSED ELECTRICAL RISER
SCALE: N.T.S.
ELECTRICAL PANEL SCHEDULES
NOT FOR CONSTRUCTION
ELEVATIONS ARE IN NAVD 88
FIRE STATION NO. 1 WIND MITIGATION
116 WEST DANIA BEACH BLVD.
DANIA BEACH, FL.
NONO DATE REVISION BY REVISIONDATE BY
SCALE
PROJECT No
SHEET
DATE:
JORGE R. CERVANTES, STATE OF FLORIDA, PROFESSIONAL ENGINEER, LICENSE NO. 45832.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY JORGE R. CERVANTES, P.E. ON
THE DATE INDICATED HERE.
PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
R
KNOW WHAT'S BELOW
A L W A Y S C A L L 8 1 1 B E F O R E Y O U D I G
It's fast. It's free. It's the law.
www.callsunshine.com
AS SHOWN E4
GROUND BONDING DETAIL
SCALE: N.T.S.
NOTE:
SUBMERSIBLE CONNECTORS DETAIL
SCALE: N.T.S.
PULL BOX DETAIL
SCALE: N.T.S.
CABLE TO GROUND ROD DETAIL
SCALE: N.T.S.
ELECTRICAL BOX GROUNDING DETAIL
SCALE: N.T.S.
GENERATOR SPECS AND
ELECTRICAL DETAILS
BID SET
NOT FOR CONSTRUCTION
ELEVATIONS ARE IN NAVD 88
FIRE STATION NO. 1 WIND MITIGATION
116 WEST DANIA BEACH BLVD.
DANIA BEACH, FL.
NONO DATE REVISION BY REVISIONDATE BY
SCALE
PROJECT No
SHEET
DATE:
JORGE R. CERVANTES, STATE OF FLORIDA, PROFESSIONAL ENGINEER, LICENSE NO. 45832.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY JORGE R. CERVANTES, P.E. ON
THE DATE INDICATED HERE.
PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
R
KNOW WHAT'S BELOW
A L W A Y S C A L L 8 1 1 B E F O R E Y O U D I G
It's fast. It's free. It's the law.
www.callsunshine.com
AS SHOWN E5
GENERATOR DETAILS
NOT FOR CONSTRUCTION
ELEVATIONS ARE IN NAVD 88
FIRE STATION NO. 1 WIND MITIGATION
116 WEST DANIA BEACH BLVD.
DANIA BEACH, FL.
NONO DATE REVISION BY REVISIONDATE BY
SCALE
PROJECT No
SHEET
DATE:
JORGE R. CERVANTES, STATE OF FLORIDA, PROFESSIONAL ENGINEER, LICENSE NO. 45832.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY JORGE R. CERVANTES, P.E. ON
THE DATE INDICATED HERE.
PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
R
KNOW WHAT'S BELOW
A L W A Y S C A L L 8 1 1 B E F O R E Y O U D I G
It's fast. It's free. It's the law.
www.callsunshine.com
AS SHOWN E6
EXISTING
BUILDING
EXISTING
BUILDING
EXISTING
BUILDING
EXISTING
BUILDING
EXISTING
BUILDING
EXISTING
BUILDING
FIRE
STATION #1
S-3
WEST DANIA BEACH BLVD
N W rd
A
VE
N U
E
HILL STREET
CV
Project Name:
Drawing Title
AS NOTED
220601
04-28-26
EMS
FIRESTATION
NO.1 WIND
MITIGATION
CITY OF DANIA
BEACH
116 WEST DANIA
BEACH BLVD,
DANIA BEACH, FLORIDA
LN
LN
Design:
Job Number:
Drawing Number:
Date:
Checked:
Drawn:
Scale:
2211 NORTHEAST 54TH STREET
FORT LAUDERDALE, FLORIDA 33308
LAKDAS/YOHALEM ENGINEERING, INC.
(954)771-0630 FAX:(954)771-0519
FL. LIC.: CA-5458
CONSULTING ENGINEERS
ALL DRAWINGS AND WRITTEN
MATERIAL HEREIN, AS
INSTRUMENTS OF SERVICE,
SHALL REMAIN THE PROPERTY
OF LAKDAS/YOHALEM
ENGINEERING, INC. (LYE) AND
SHALL NOT BE REPRODUCED
OR COPIED, IN WHOLE OR IN
PART, WITHOUT THE
EXPRESSED WRITTEN CONSENT
OF "LYE" AND MAY NOT BE
USED OR REFERENCED FOR
ANY OTHER PROJECT.
INFORMATION CONTAINED
HEREIN REPRESENTS
PROPRIETARY INFORMATION OF
LAKDAS/YOHALEM ENGINEERING
INC. AND / OR ITS CLIENT
AND SHALL NOT BE DISCLOSED
TO OTHERS.
LAKDAS/YOHALEM ENGINEERING,
INC. SHALL BE AFFORDED THE
OPPORTUNITY TO PROVIDE
CONSTRUCTION OBSERVATION
SERVICES DURING THE FRAME
ERECTION OF THIS PROJECT. IN
THE EVENT LAKDAS/YOHALEM
ENGINEERING, INC. IS NOT
RETAINED IN THIS CAPACITY,
LAKDAS/YOHALEM ENGINEERING,
INC. CAN ASSUME NO
RESPONSIBILITY FOR THE
CONSTRUCTION DEFECTS FOR
THE RECOMMENDATIONS
PROVIDED IN THESE DOCUMENTS.
e-mail: lye@lyengineering.com
Revision
NO. Description Date
L A
K D
A S
N A N A Y A K
K A
R A
P R
O F
E
S S I O N A L E N G
I
N E
E R
S T
A T
E O F F L O
R I
D A
P.E. # 037590
DRY RUN
NOT FOR CONSTRUCTION
ELEVATIONS ARE IN NAVD 88
INDEX SHEET
CITY OF DANIA BEACH FIRE STATION
SHEET No. DESCRIPTION
SOUTH FLORIDA GOOGLE MAP
116 WEST DANIA BEACH BLVD.
DANIA BEACH, FLORIDA, 33004
PROJECT LOCATION
(116 WEST DANIA
BEACH BLVD., DANIA
BEACH, FL)
INDEX SHEETCV
S-1 FIRST FLOOR PLAN
S-2
ROOF PLAN
INDEX
S-3
NEW ROOF PLAN
S-4
ROOFING DETAILS
S-6
ROOF DESIGN WIND PRESSURES AND
SOUTHWEST ELEVATION
SITE PLAN2
CV SCALE: NTS NORTH
VICINITY MAP1
CV SCALE: NTS NORTH
SCOPE OF WORK
· REPLACE IDENTIFIED DOOR WITH NEW IMPACT DOORS W/
MIAMI DADE COUNTY PRODUCT APPROVAL
· CONSTRUCT NEW CONCRETE PAD TO SUPPORT NEW ELECTRIC
GENERATOR
· RE-ROOF ALL ROOF AREAS
· INSTALL NEW ACCESS LADDER AND TIE DOWN AROUND
EXISTING MECHANICAL UNITS.
S-5 DEMOLITION PLAN
S-7
GENERATOR SLAB & NEW WALL INFILL
S-8 S-9 S-10
EXISTING ROOFING
WIND PRESSURES ON COMPONENTS
ACCESS LADDER AND ROOF PENETRATION
AND GENERAL NOTES BID SET 04-28-2026
ROOFING DETAILS
S-11
5'-8" 6'-0" 9'-4" 2'-8"6'-0"28'-4"12'-0"
4'-0" 6'-4" 9'-4" 4'-0" 10'-0" 4'-0" 14'-0" 6'-4" 9'-8" 6'-4" 5'-6"14'-6"
4' -4
3'-0"
4' -0
9'
-8
4' -0
6'
-4
4' -8
3'
-4
'-1
0" 3'
-4 "1'
-0 " 3'
-1 0"
1' -0
'-0
1' -0
'-0
1' -0
'-0
4' -0
9'
-8
9'-0" 1'-0" 5'-8" 5'-4" 1'-0"
4' -0
'-0
9' -8
1'
-0
'-0
1'
-0
3' -4
4'
-8
'-1
4'
-4
1' -3
6'
-0
4' -0
4'
-2
3' -2
4'
-0
2' -8
3'
-4
2' -8
4'
-0
3' -4
9'
-0
94'-0"
9'
-0
95'-0"
1514 13
RE: DETAIL
1/S-3
107 A
123 E
123 D
L5
L4L3L2
L1
123 A
123 B
123 C
L7 L8
123G121
123 F
DENOTES WORK INCLUDED
IN THIS CONTRACT.
REFER TO TABLE IN 5/S-2
RE: DETAIL
2/S-3
RE: DETAIL
2/S-3
130 131132 5 S-3
S-1
Project Name:
Drawing Title
AS NOTED
220601
04-28-26
EMS
FIRESTATION
NO.1 WIND
MITIGATION
CITY OF DANIA
BEACH
116 WEST DANIA
BEACH BLVD,
DANIA BEACH, FLORIDA
LN
LN
Design:
Job Number:
Drawing Number:
Date:
Checked:
Drawn:
Scale:
2211 NORTHEAST 54TH STREET
FORT LAUDERDALE, FLORIDA 33308
LAKDAS/YOHALEM ENGINEERING, INC.
(954)771-0630 FAX:(954)771-0519
FL. LIC.: CA-5458
CONSULTING ENGINEERS
ALL DRAWINGS AND WRITTEN
MATERIAL HEREIN, AS
INSTRUMENTS OF SERVICE,
SHALL REMAIN THE PROPERTY
OF LAKDAS/YOHALEM
ENGINEERING, INC. (LYE) AND
SHALL NOT BE REPRODUCED
OR COPIED, IN WHOLE OR IN
PART, WITHOUT THE
EXPRESSED WRITTEN CONSENT
OF "LYE" AND MAY NOT BE
USED OR REFERENCED FOR
ANY OTHER PROJECT.
INFORMATION CONTAINED
HEREIN REPRESENTS
PROPRIETARY INFORMATION OF
LAKDAS/YOHALEM ENGINEERING
INC. AND / OR ITS CLIENT
AND SHALL NOT BE DISCLOSED
TO OTHERS.
LAKDAS/YOHALEM ENGINEERING,
INC. SHALL BE AFFORDED THE
OPPORTUNITY TO PROVIDE
CONSTRUCTION OBSERVATION
SERVICES DURING THE FRAME
ERECTION OF THIS PROJECT. IN
THE EVENT LAKDAS/YOHALEM
ENGINEERING, INC. IS NOT
RETAINED IN THIS CAPACITY,
LAKDAS/YOHALEM ENGINEERING,
INC. CAN ASSUME NO
RESPONSIBILITY FOR THE
CONSTRUCTION DEFECTS FOR
THE RECOMMENDATIONS
PROVIDED IN THESE DOCUMENTS.
e-mail: lye@lyengineering.com
Revision
NO. Description Date
L A
K D
A S
N A N A Y A K
K A
R A
P R
O F
E
S S I O N A L E N G
I
N E
E R
S T
A T
E O F F L O
R I
D A
P.E. # 037590
DRY RUN
NOT FOR CONSTRUCTION
ELEVATIONS ARE IN NAVD 88
FIRST
FLOOR PLAN
FIRST FLOOR PLAN1
S-1 SCALE: NTS NORTH
01 NOT USED
02 NOT USED
03 CORRODED DOUBLE DOOR
04 100 LF CRACKS SIDEWALK/DRIVEWAY
05 SETTLEMENT
06 WASHOUT UNDER PATIO SLAB
07 NOT USED
08 NOT USED
NOT USED10
11 NOT USED
12 LEAKING FROM ROOF
13 STEP CRACK
14 STEP CRACK
15 WALL CRACK
16 BAY DOOR BROKEN
NOT USED
BID SET 04-28-2026
REFERENCE PHOTO OF DEFECTS2
S-1 SCALE: NTS
ALL WINDOWS ARE NOT
INCLUDED IN THIS CONTRACT
FOR VIEW OF BUILDING ELEVATIONS,
SEE SHEET S-2
123 E 123 D123 F003107 A
L1
L2L3L4
L5
T.O. PARAP. CAP
FINISH FLOOR
ELEV. +0'-0"
ELEV. +14-6"
T.O. PARAP. CAP
FINISH FLOOR
ELEV. +0'-0"
ELEV. +16'-0"
ENCLOSED EXISTING MASONRY WALL OPENING WITH NEW REINFORCED MASONRY WALL.
FINISH WITH STUCCO OUTSIDE AND FINISHED WITH FURRING AND DRYWALL INSIDE.
FINISH WALL TO MATCH EXISTING.
123 A 123 B 123 C
T.O. PARAP. CAP
FINISH FLOOR
ELEV. +0'-0"
ELEV. +14-6"
T.O. PARAP. CAP
FINISH FLOOR
ELEV. +0'-6"
ELEV. +16'-0"
L8
L7 S-2
Project Name:
Drawing Title
AS NOTED
220601
04-28-26
EMS
FIRESTATION
NO.1 WIND
MITIGATION
CITY OF DANIA
BEACH
116 WEST DANIA
BEACH BLVD,
DANIA BEACH, FLORIDA
LN
LN
Design:
Job Number:
Drawing Number:
Date:
Checked:
Drawn:
Scale:
2211 NORTHEAST 54TH STREET
FORT LAUDERDALE, FLORIDA 33308
LAKDAS/YOHALEM ENGINEERING, INC.
(954)771-0630 FAX:(954)771-0519
FL. LIC.: CA-5458
CONSULTING ENGINEERS
ALL DRAWINGS AND WRITTEN
MATERIAL HEREIN, AS
INSTRUMENTS OF SERVICE,
SHALL REMAIN THE PROPERTY
OF LAKDAS/YOHALEM
ENGINEERING, INC. (LYE) AND
SHALL NOT BE REPRODUCED
OR COPIED, IN WHOLE OR IN
PART, WITHOUT THE
EXPRESSED WRITTEN CONSENT
OF "LYE" AND MAY NOT BE
USED OR REFERENCED FOR
ANY OTHER PROJECT.
INFORMATION CONTAINED
HEREIN REPRESENTS
PROPRIETARY INFORMATION OF
LAKDAS/YOHALEM ENGINEERING
INC. AND / OR ITS CLIENT
AND SHALL NOT BE DISCLOSED
TO OTHERS.
LAKDAS/YOHALEM ENGINEERING,
INC. SHALL BE AFFORDED THE
OPPORTUNITY TO PROVIDE
CONSTRUCTION OBSERVATION
SERVICES DURING THE FRAME
ERECTION OF THIS PROJECT. IN
THE EVENT LAKDAS/YOHALEM
ENGINEERING, INC. IS NOT
RETAINED IN THIS CAPACITY,
LAKDAS/YOHALEM ENGINEERING,
INC. CAN ASSUME NO
RESPONSIBILITY FOR THE
CONSTRUCTION DEFECTS FOR
THE RECOMMENDATIONS
PROVIDED IN THESE DOCUMENTS.
e-mail: lye@lyengineering.com
Revision
NO. Description Date
L A
K D
A S
N A N A Y A K
K A
R A
P R
O F
E
S S I O N A L E N G
I N
E E
R
S T
A T
E O F F L O
R I
D A
P.E. # 037590
DRY RUN
NOT FOR CONSTRUCTION
ELEVATIONS ARE IN NAVD 88
WIND PRESSURES
ON COMPONENTS
SOUTHWEST ELEVATION1
S-2 SCALE: 3/32"=1'-0"
SOUTHEAST ELEVATION2
S-2 SCALE: 3/32"=1'-0"
NORTHEAST ELEVATION3
S-2 SCALE: 3/32"=1'-0"
NORTHWEST ELEVATION4
S-2 SCALE: 3/32"=1'-0"
WIND PRESSURES5
S-2 SCALE: NTS
NOTES:
1. CONTRACTOR TO MAKE A SITE VISIT PRIOR TO BIDDING AND REVIEW ANY ATTACHMENT TO
ALL DOORS AND LOUVER OPENING. INCLUDE COST OF REMOVAL AND REPAIR OF THE WALL
OPENING ON BOTH INSIDE AND OUTSIDE. PAINT BOTH WALL FACES TO MATCH EXISTING FINISH.
NOTES:
1. CONTRACTOR TO VERIFY AND COORD. ALL MASONRY WALL
ROUGH OPENINGS AND FIELD VERIFY PRIOR TO
FABRICATION.
2. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR
ENGINEER FOR APPROVAL.
3. ANY QUESTIONS OR DISCREPANCIES SHALL BE REPORTED
TO THE ENGINEER PRIOR TO FABRICATION.
WINDOWS INSTALLATION FOR THIS PROJECT HAS BEEN
COMPLETED UNDER PERMIT # 2022-00002092 AND
PERMIT # 2022-00001436.
NOTES :
1. DOORS AND LOUVERS TO BE MIAMI DADE COUNTY
APPROVED
2. CONTRACTOR TO PROVIDE NOTICE OF ACCEPTANCE
FOR E.OR. REVIEW AND APPROVAL PRIOR TO
FRABRICATION / INSTALLATION
ALL WINDOWS ARE NOT
INCLUDED IN THIS CONTRACT
DOOR/ LOUVER
DOORS: 107A, 003 3'-0"x6'-8"
DIMENSIONS
(BxH)
123C, 123D, 123E
(ROLLER DOORS)
12'-0"x12'-0"
LOUVERS: L1, L5 5'-0"x5'-0"
L2, L4
L3
6'-0"x2'-0"
3'-0"x2'-0" +42 -45
+41 -55
+39 -43
+35 -38
+40 -52
+40 -52
123A, 123B
(ROLLER DOORS)
12'-0"x12'-0" +35 -38
3'-3"x6'-9"
L7 3'-4"x1'-4" +42 -45 L8 3'-4"x1'-4" +42 -45
WIND PRESSURES IN COMPONENTS
PER ASCE 7-22 & FBC 2023, 8th EDITION
V=187 MPH, EXPOSURE C, CATEGORY IV
ALLOWABLE DESIGN
PRESSURE PER
WIND ANALYSIS
(PSF)
ULTIMATE DESIGN
PRESSURE PER
WIND ANALYSIS
(PSF)
+68 -75
+68 -92
+65 -72
+58 -64
+66 -86
+67 -87
+58 -64
+68 -75
+68 -75
123F, 124
3'-1"x6'-8"
2'-11"x6'-8"
2'-11"x6'-11"
2'-11"x6'-7"
+40 -44 +67 -73
+40 -44 +67 -73
+40 -44 +67 -73
+40 -52 +66 -86
(*) DOOR LOCK MECHANISM WITH PANIC BAR FROM INSIDE;
CAN OPEN FROM OUTSIDE WITH HANDRAIL.
123G 3'-0"x6'-7" +40 -44 +67 -73 (*)
BID SET 04-28-2026
DENOTES WORK NOT
INCLUDED IN THIS CONTRACT
130, 131 3'-0"x8'-0" +40 -43 +66 -72
(ROLLER DOOR)
5'-9"x9'-0" +38 -41 +63 -68
COMPACT
SUBGRADE
10" THICK CONCRETE SLAB ON
GRADE W/ THICKENED EDGE.
(2) #5 CONT.
22'-0"
2'-0"
6" 1'
-0
#4 @ 10" O.C.
ALL AROUND
2'-0"
3/4" CHAMFER
EDGE
ALL AROUND
F.F.E. +12.00'
2'-0"
11'-0" 11'-0"
(2) #5 CONT.
#4 @ 10" O.C.
TOTAL WEIGHT CONSIDERED:
GENERATOR/ENCLOSURE + DIESEL TANK = 9,290 LBS
6"
SECTION
1/ 8"
T O
' S
LO
PE
#5 @ 10" O.C.
TOP & BOTTOM
#5
0"
O .C
TO
P
BO
TT
O M
3/4" CHAMFER
EDGE
ALL AROUND
3' -6
4'
-2
3'-6"
15'-0" (180")
3' -6
PLAN
22'-0"
'-2
CONDUIT
STUB AREA
GENERATOR
OUTLINE
3'-6"
THICKENED
EDGE LINE
GENERATOR
EXISTING CONCRETE
SLAB
EXISTING CONCRETE
BEAM TO REMAIN
#5 -18" LONG EPOXY
(SIKADUR EPOXY GEL) BAR
INTO EXISTING COLUMN (TO
BE VIF BY CONTRACTOR) W/
6" EMBEDMENT @ 12" O.C
(EACH SIDE)
NEW WALL INFILL
EXISTING CONCRETE SLAB
EXISTING TIE BEAM
#5 -18" LONG EPOXY
(SIKADUR EPOXY GEL) BAR
INTO EXISTING COLUMN (TO
BE VIF BY CONTRACTOR) W/
6" EMBEDMENT @ 12" O.C
(EACH SIDE) (TYP)
6'-0" (VIF)
NEW WALL INFILL
4'-4" (VIF)
NEW WALL INFILL
EXISTING TIE BEAM
EXISTING WALL
1'-0"
VIF
8" VI
F
7' -6
" V
IF
#5 -18" LONG EPOXY
(SIKADUR EPOXY GEL) BAR
INTO EXISTING COLUMN (TO
BE VIF BY CONTRACTOR) W/
6" EMBEDMENT @ 12" O.C
(EACH SIDE) (TYP)
EXISTING DOUBLE
TEE (TYP)
CL CL
EXISTING ROOF
TOP UNIT AND
COMPONENTS
RTU1/4" Ø S.S AIRCRAFT
CABLE W/
TURNBUCKLES (TYP)
3/8" Ø S.S EPOXY
EYE BOLT W./ 4"
EMBEDMENT (TYP)
1/4" Ø S.S
AIRCRAFT CABLE
W/ TURNBUCKLES
(TYP)
3/8" Ø S.S EPOXY
EYE BOLT W./ 4"
EMBEDMENT (TYP)
1' -0
1' -0
NOTE:
COORDINATE LOCATION
WITH ROOF EQUIPMENT
AND DOUBLE TEE STEM
EXISTING DOUBLE
TEE (TYP)
PLAN
SECTION
EXISTING CONCRETE
SLAB
3'-0"
8' -2
S-3
Project Name:
Drawing Title
AS NOTED
220601
04-28-26
EMS
FIRESTATION
NO.1 WIND
MITIGATION
CITY OF DANIA
BEACH
116 WEST DANIA
BEACH BLVD,
DANIA BEACH, FLORIDA
LN
LN
Design:
Job Number:
Drawing Number:
Date:
Checked:
Drawn:
Scale:
2211 NORTHEAST 54TH STREET
FORT LAUDERDALE, FLORIDA 33308
LAKDAS/YOHALEM ENGINEERING, INC.
(954)771-0630 FAX:(954)771-0519
FL. LIC.: CA-5458
CONSULTING ENGINEERS
ALL DRAWINGS AND WRITTEN
MATERIAL HEREIN, AS
INSTRUMENTS OF SERVICE,
SHALL REMAIN THE PROPERTY
OF LAKDAS/YOHALEM
ENGINEERING, INC. (LYE) AND
SHALL NOT BE REPRODUCED
OR COPIED, IN WHOLE OR IN
PART, WITHOUT THE
EXPRESSED WRITTEN CONSENT
OF "LYE" AND MAY NOT BE
USED OR REFERENCED FOR
ANY OTHER PROJECT.
INFORMATION CONTAINED
HEREIN REPRESENTS
PROPRIETARY INFORMATION OF
LAKDAS/YOHALEM ENGINEERING
INC. AND / OR ITS CLIENT
AND SHALL NOT BE DISCLOSED
TO OTHERS.
LAKDAS/YOHALEM ENGINEERING,
INC. SHALL BE AFFORDED THE
OPPORTUNITY TO PROVIDE
CONSTRUCTION OBSERVATION
SERVICES DURING THE FRAME
ERECTION OF THIS PROJECT. IN
THE EVENT LAKDAS/YOHALEM
ENGINEERING, INC. IS NOT
RETAINED IN THIS CAPACITY,
LAKDAS/YOHALEM ENGINEERING,
INC. CAN ASSUME NO
RESPONSIBILITY FOR THE
CONSTRUCTION DEFECTS FOR
THE RECOMMENDATIONS
PROVIDED IN THESE DOCUMENTS.
e-mail: lye@lyengineering.com
Revision
NO. Description Date
L A
K D
A S
N A N A Y A K
K A
R A
P R
O F
E
S S I O N A L E N G
I
N E
E R
S T
A T
E O F F L O
R I
D A
P.E. # 037590
DRY RUN
NOT FOR CONSTRUCTION
ELEVATIONS ARE IN NAVD 88
GENERATOR SLAB &
NEW WALL INFILL
GENERATOR SUPPORT SLAB AND FOUNDATION3
S-3 SCALE: 1/2"=1'-0"
CMU WALL INFILL1
S-3 SCALE: NTS
NORTH
BID SET 04-28-2026
CMU WALL INFILL2
S-3 SCALE: 1/2"=1'-0"
ROOF EQUIPMENT TIE DOWN (TYP)4
S-3 SCALE: NTS
EXISTING DOUBLE DOOR AND LOUVER TO
BE REMOVED AND FILL WITH MASONRY
(REFERENCE PHOTO)
EXISTING LOUVER TO BE REMOVED AND
FILL WITH MASONRY
(REFERENCE PHOTO)
S-3
NEW LINTEL IN DOOR 131
SCALE: 1/2"=1'-0"
EXISTING 2x10 @ 24" O.C
EXISTING WOOD
TRUSSES @ 24" O.C
EXISTING DOUBLE TEE BEAMSEXISTING DOUBLE TEE BEAMS
EXISTING RTU
'-8
79'-6"
'-0
61'-0"
'-4
14'-6"
'-4
9'
-8
12'-0" 22'-0"
S-4
Project Name:
Drawing Title
AS NOTED
220601
04-28-26
EMS
FIRESTATION
NO.1 WIND
MITIGATION
CITY OF DANIA
BEACH
116 WEST DANIA
BEACH BLVD,
DANIA BEACH, FLORIDA
LN
LN
Design:
Job Number:
Drawing Number:
Date:
Checked:
Drawn:
Scale:
2211 NORTHEAST 54TH STREET
FORT LAUDERDALE, FLORIDA 33308
LAKDAS/YOHALEM ENGINEERING, INC.
(954)771-0630 FAX:(954)771-0519
FL. LIC.: CA-5458
CONSULTING ENGINEERS
ALL DRAWINGS AND WRITTEN
MATERIAL HEREIN, AS
INSTRUMENTS OF SERVICE,
SHALL REMAIN THE PROPERTY
OF LAKDAS/YOHALEM
ENGINEERING, INC. (LYE) AND
SHALL NOT BE REPRODUCED
OR COPIED, IN WHOLE OR IN
PART, WITHOUT THE
EXPRESSED WRITTEN CONSENT
OF "LYE" AND MAY NOT BE
USED OR REFERENCED FOR
ANY OTHER PROJECT.
INFORMATION CONTAINED
HEREIN REPRESENTS
PROPRIETARY INFORMATION OF
LAKDAS/YOHALEM ENGINEERING
INC. AND / OR ITS CLIENT
AND SHALL NOT BE DISCLOSED
TO OTHERS.
LAKDAS/YOHALEM ENGINEERING,
INC. SHALL BE AFFORDED THE
OPPORTUNITY TO PROVIDE
CONSTRUCTION OBSERVATION
SERVICES DURING THE FRAME
ERECTION OF THIS PROJECT. IN
THE EVENT LAKDAS/YOHALEM
ENGINEERING, INC. IS NOT
RETAINED IN THIS CAPACITY,
LAKDAS/YOHALEM ENGINEERING,
INC. CAN ASSUME NO
RESPONSIBILITY FOR THE
CONSTRUCTION DEFECTS FOR
THE RECOMMENDATIONS
PROVIDED IN THESE DOCUMENTS.
e-mail: lye@lyengineering.com
Revision
NO. Description Date
L A
K D
A S
N A N A Y A K
K A
R A
P R
O F
E
S S I O N A L E N G
I
N E
E R
S T
A T
E O F F L O
R I
D A
P.E. # 037590
DRY RUN
NOT FOR CONSTRUCTION
ELEVATIONS ARE IN NAVD 88
ROOF PLAN
EXISTING ROOF PLAN1
S-4 SCALE: NTS NORTH
01 PONDING RAINWATER 02 PONDING RAINWATER 03 PONDING RAINWATER
04 VEGETATION AND ORGANIC DEBRIS
05 PONDING/LEAKING/ BUBBLING 06 BUBBLING THROUGHOUT
07 HATCHES NOT STRAPPED 08 MECH. UNITS NOT STRAPPED
09 MECH. UNITS NOT STRAPPED 10 HOLE CUT INTO EXISTING
DOUBLE-T. EXPOSED REBAR
BID SET 04-28-2026
REFERENCE PHOTO2
S-4 SCALE: NTS
NOTE:
ALL DIMENSIONS TO BE
VERIFIED AT SITE PRIOR TO
EXECUTIONS / CONSTRUCTION.
EXISTING RTU
TO REMAIN
REMOVE EXISTING
HATCH . CLOSE
EXISTING
OPENING. RE: 5/S-9
S-9
EXISTING CANOPY.
NOT INCLUDED IN
THIS CONTRACT
EXISTING OVERFLOW
SCUPPER TO BE
REMOVED
'-0
79'-6"
'-0
61'-0"
'-4
9'
-8
22'-0"12'-0"
9' -8
'-4
14'-6"
EXISTING RTU
TO REMAIN
EXISTING
ROOF DRAIN
TO BE
REMOVED
3"3"
.5
3"
20"
3"
8"
3"
12" 12"
EXISTING OVERFLOW
SCUPPER.
TO BE REMOVED
EXISTING OVERFLOW
SCUPPER TO BE
REMOVED
EXISTING OVERFLOW
SCUPPER TO BE
REMOVED
EXISTING OVERFLOW
SCUPPER TO BE
REMOVED
SLOPE
ROOF #3
ROOF #2
ROOF #1
EXISTING OVERFLOW
SCUPPER TO BE
REMOVED
EXISTING
ROOF DRAIN
TO BE
REMOVED
EXISTING
ROOF DRAIN
TO BE
REMOVED
EXISTING
ROOF DRAIN
TO BE
REMOVED
EXISTING
ROOF DRAIN
TO BE
REMOVED
EXISTING OVERFLOW
SCUPPER TO BE
REMOVED
EXISTING OVERFLOW
SCUPPER TO BE
REMOVED
EXISTING
MECH. UNIT
TO REMAIN EXISTING
MECH. UNIT
TO REMAIN
EXISTING OVERFLOW
SCUPPER TO BE
REMOVED
EXISTING OVERFLOW
SCUPPER TO BE
REMOVED
EXISTING OVERFLOW
SCUPPER TO BE
REMOVED
EXISTING
MECH. UNIT
TO REMAIN
CUT EXISTING
CONCRETE FOR NEW
OVERFLOW SCUPPER
1'-0"
6"
EXISTING ROOFING TO BE
REMOVED AND REPLACE
EXISTING ROOFING TO BE
REMOVED AND REPLACE
EXISTING ROOFING TO BE
REMOVED AND REPLACE
EXISTING DOUBLE
DOOR TO BE
REMOVED
EXISTING LOUVER TO
BE REMOVED
EXISTING
MECH. UNIT
TO REMAIN
S-5
Project Name:
Drawing Title
AS NOTED
220601
04-28-26
EMS
FIRESTATION
NO.1 WIND
MITIGATION
CITY OF DANIA
BEACH
116 WEST DANIA
BEACH BLVD,
DANIA BEACH, FLORIDA
LN
LN
Design:
Job Number:
Drawing Number:
Date:
Checked:
Drawn:
Scale:
2211 NORTHEAST 54TH STREET
FORT LAUDERDALE, FLORIDA 33308
LAKDAS/YOHALEM ENGINEERING, INC.
(954)771-0630 FAX:(954)771-0519
FL. LIC.: CA-5458
CONSULTING ENGINEERS
ALL DRAWINGS AND WRITTEN
MATERIAL HEREIN, AS
INSTRUMENTS OF SERVICE,
SHALL REMAIN THE PROPERTY
OF LAKDAS/YOHALEM
ENGINEERING, INC. (LYE) AND
SHALL NOT BE REPRODUCED
OR COPIED, IN WHOLE OR IN
PART, WITHOUT THE
EXPRESSED WRITTEN CONSENT
OF "LYE" AND MAY NOT BE
USED OR REFERENCED FOR
ANY OTHER PROJECT.
INFORMATION CONTAINED
HEREIN REPRESENTS
PROPRIETARY INFORMATION OF
LAKDAS/YOHALEM ENGINEERING
INC. AND / OR ITS CLIENT
AND SHALL NOT BE DISCLOSED
TO OTHERS.
LAKDAS/YOHALEM ENGINEERING,
INC. SHALL BE AFFORDED THE
OPPORTUNITY TO PROVIDE
CONSTRUCTION OBSERVATION
SERVICES DURING THE FRAME
ERECTION OF THIS PROJECT. IN
THE EVENT LAKDAS/YOHALEM
ENGINEERING, INC. IS NOT
RETAINED IN THIS CAPACITY,
LAKDAS/YOHALEM ENGINEERING,
INC. CAN ASSUME NO
RESPONSIBILITY FOR THE
CONSTRUCTION DEFECTS FOR
THE RECOMMENDATIONS
PROVIDED IN THESE DOCUMENTS.
e-mail: lye@lyengineering.com
Revision
NO. Description Date
L A
K D
A S
N A N A Y A K
K A
R A
P R
O F
E
S S I O N A L E N G
I
N E
E R
S T
A T
E O F F L O
R I
D A
P.E. # 037590
DRY RUN
NOT FOR CONSTRUCTION
ELEVATIONS ARE IN NAVD 88
DEMOLITION
PLAN
ROOFING DEMOLITION PLAN1
S-5 SCALE: NTS NORTH
BID SET 04-28-2026
EXISTING RTU
TO REMAIN
N
EW
R O
O F
EXISTING CANOPY.
NOT INCLUDED IN
THIS CONTRACT
GALVANIZED
OVERFLOW SCUPPER.
RE: 2/S-7 (1 OF 7)
'-0
79'-6"
'-0
61'-0"
NEW ROOF ACCESS
LADDER. RE: 2/S-9
NEW ROOF ACCESS
LADDER. RE: 2/S-9
'-4
9'
-8
22'-0"12'-0"
9' -8
'-4
14'-6"
VERIFY AT SITE
VERIFY AT SITE
S-3
TYPICAL
NEW ROOF ACCESS
LADDER. RE: 1/S-9
C O
O R
D
IN
AT
E
W / C
IT
Y
ST
AF
F
SL
O
PE
1/
8" T
O
'-0
NEW ROOFING
NEW ROOF
INSTALL NEW
ROOF DRAIN
(TYP.)
RE: 3/S-9
NEW ROOFING
7' -8
12'-10"
8' -0
8' -0
N
EW
R O
O F
N
EW
R O
O F
GALVANIZED
OVERFLOW SCUPPER.
RE: 3/S-8
GALVANIZED
OVERFLOW SCUPPER.
RE: 3/S-8
GALVANIZED
OVERFLOW SCUPPER.
RE: 3/S-8
INSTALL NEW
ROOF DRAIN
(TYP.)
RE: 3/S-9
ROOF #3
ROOF #1
NEW ROOF
S-3
S-3
TYPICAL
S-3
TYPICAL
ROOF PENETRATION
(TYP.) RE: 4/S-9
ROOF PENETRATION
(TYP.) RE: 4/S-9
ROOF PENETRATION
(TYP.) RE: 4/S-9
ROOF PENETRATION
(TYP.) RE: 4/S-9
S-7
S-8
S-7
S-8
S-7
GALVANIZED
OVERFLOW SCUPPER.
RE: 3/S-8
S-7
GALVANIZED
OVERFLOW SCUPPER.
RE: 2/S-7
GALVANIZED
OVERFLOW SCUPPER.
RE: 2/S-7
1'-0"
INSTALL NEW
ROOF DRAIN
(TYP.)
RE: 3/S-9
SLOPE 1/8" TO 1'-0"
SL
O
PE
/8 " T
O
'-0
SLOPE 1/8" TO 1'-0" SLOPE 1/8" TO 1'-0"SLOPE
1/8" TO 1'-0"
EXISTING RTU
TO REMAIN
NEW ROOFING
NEW ROOFING
ROOF #2
INSTALL NEW
ROOF DRAIN
(TYP.)
RE: 3/S-9
SL
O
PE
/8 " T
O
'-0
SL
O
PE
/8 " T
O
'-0
SL
O
PE
/8 " T
O
'-0
SLOPE 1/8" TO 1'-0"
SLOPE 1/8" TO 1'-0" SLOPE 1/8" TO 1'-0"
SL
O
PE
/8 " T
O
'-0
SL
O
PE
/8 " T
O
'-0
SL
O
PE
/8 " T
O
'-0
SL
O
PE
/8 " T
O
'-0
SLOPE
1/8" TO 1'-0"
SL
O
PE
1/
8" T
O
'-0
SL
O
PE
1/
8" T
O
'-0
SL
O
PE
1/
8" T
O
'-0
SLOPE
1/8" TO 1'-0"
BUILT PARAPET WALL
MINIMUM 14" ABOVE
CONCRETE DECK.
(SEE DETAIL 1/S-8)
VERIFY EXISTING SIZE OF
DOWNSPOUT. MIN 12 SQ
IN. REQUIREMENT.
ROOF PLAN1
S-6 SCALE: NTS NORTH
S-6
Project Name:
Drawing Title
AS NOTED
220601
04-28-26
EMS
FIRESTATION
NO.1 WIND
MITIGATION
CITY OF DANIA
BEACH
116 WEST DANIA
BEACH BLVD,
DANIA BEACH, FLORIDA
LN
LN
Design:
Job Number:
Drawing Number:
Date:
Checked:
Drawn:
Scale:
2211 NORTHEAST 54TH STREET
FORT LAUDERDALE, FLORIDA 33308
LAKDAS/YOHALEM ENGINEERING, INC.
(954)771-0630 FAX:(954)771-0519
FL. LIC.: CA-5458
CONSULTING ENGINEERS
ALL DRAWINGS AND WRITTEN
MATERIAL HEREIN, AS
INSTRUMENTS OF SERVICE,
SHALL REMAIN THE PROPERTY
OF LAKDAS/YOHALEM
ENGINEERING, INC. (LYE) AND
SHALL NOT BE REPRODUCED
OR COPIED, IN WHOLE OR IN
PART, WITHOUT THE
EXPRESSED WRITTEN CONSENT
OF "LYE" AND MAY NOT BE
USED OR REFERENCED FOR
ANY OTHER PROJECT.
INFORMATION CONTAINED
HEREIN REPRESENTS
PROPRIETARY INFORMATION OF
LAKDAS/YOHALEM ENGINEERING
INC. AND / OR ITS CLIENT
AND SHALL NOT BE DISCLOSED
TO OTHERS.
LAKDAS/YOHALEM ENGINEERING,
INC. SHALL BE AFFORDED THE
OPPORTUNITY TO PROVIDE
CONSTRUCTION OBSERVATION
SERVICES DURING THE FRAME
ERECTION OF THIS PROJECT. IN
THE EVENT LAKDAS/YOHALEM
ENGINEERING, INC. IS NOT
RETAINED IN THIS CAPACITY,
LAKDAS/YOHALEM ENGINEERING,
INC. CAN ASSUME NO
RESPONSIBILITY FOR THE
CONSTRUCTION DEFECTS FOR
THE RECOMMENDATIONS
PROVIDED IN THESE DOCUMENTS.
e-mail: lye@lyengineering.com
Revision
NO. Description Date
L A
K D
A S
N A N A Y A K
K A
R A
P R
O F
E
S S I O N A L E N G
I
N E
E R
S T
A T
E O F F L O
R I
D A
P.E. # 037590
DRY RUN
NOT FOR CONSTRUCTION
ELEVATIONS ARE IN NAVD 88
NEW ROOF
PLAN
BID SET 04-28-2026
03 REFERENCE PHOTO OF ROOF #3
02 REFERENCE PHOTO OF ROOF #2
01 REFERENCE PHOTO OF ROOF #1
REFERENCE PHOTOS2
S-6 SCALE: NTS
NOTE:
ALL DIMENSIONS TO BE
VERIFIED AT SITE PRIOR TO
EXECUTIONS / CONSTRUCTION.
BASE FLASHING
OVER 4" CANT STRIP
SLOPE ROOF TO
ROOF DRAIN
8"x16" POWDER COATED
ALUMINUM OVERFLOW
SCUPPER @ 3" ABOVE
LOW POINT OF ROOF
ELEV.:
L.P OF ROOF
(SEE ROOF PLAN) EXISTING ROOF
STRUCTURE A PER
ROOF FRAMING PLAN
2"
ROOF AS PER
DETAIL 1/S-4
EXISTING BUILDING
STRUCTURE
CONT. 2x8 PT WOOD
NAILER
CONT. 20 GA. ALUM.
CAP FLASHING
FASTENED TO METAL
CLEAT AND KEEPER
STRIP EXTEND BASE ROOFING
MEMBRANE OVER
PARAPET (TYP)
SLOPE
ELEV.:
T.O PARAPET
14'-6" VIF
EXTEND ROOF
MEMBRANE TO TOP
OF PARAPET (TYP)
VULKEM PRIMER &
SEALANT
EXISTING BUILDING
STRUCTURE
CONT. 2x10 PT WOOD
NAILER
CONT. 20 GA. ALUM.
CAP FLASHING
FASTENED TO METAL
CLEAT AND KEEPER
STRIP
EXTEND BASE ROOFING
MEMBRANE OVER
PARAPET (TYP)
5" CONT. FIBER CANT
STRIP
SLOPE
RE-ROOF WITH 4-PLYS TORCH
DOWN BUILT-UP ROOFING
OVER R-19 TAPERED
INSULATION ON EXISTING 5/8"
EXTERIOR GRADE APA
PLYWOOD DECK
EXISTING ROOF
STRUCTURE A PER
ROOF FRAMING PLAN
SLOPE AS PER PLAN
NOTE:
VERIFY CONDITION OF EXISTING
EXTERIOR SUBSTRATE PRIOR
TO RECOVERY BOARD AND
BASE SHEET INSTALLATION
ELEV.:
T.O PARAPET
14'-6" VIF
6" V
IF
EXISTING MASONRY
WALL
CONT. 20 GA. ALUM. CAP FLASHING
FASTENED TO METAL CLEAT AND
KEEPER STRIP
CONT. FIBER CANT
STRIP
EXTEND BASE ROOFING
MEMBRANE OVER
PARAPET (TYP)
RE-ROOF WITH 4-PLYS TORCH
DOWN BUILT-UP ROOFING
OVER R-19 TAPERED
INSULATION ON EXISTING
CONCRETE DOUBLE TEE. (
ELEVATION MATCH WITH
EXISTING)
8" VIF
ELEV.:
T.O EXISTING PARAPET
=+16'-0" VIF
CONT. 6" WIDE-18 GAUGE GALVANIZED
TOP AND BOTTOM TRACK
CONT. 10" WIDE -18 GAUGE
GALVANIZED METAL STUD @ 16" O.C.
CONT. 2"x10" P.T. WOOD
WIRE LATH W/ 5/8" MIN.
STUCCO
CONT. 2"X5" PT. WOOD
SLOPE
8" M
IN
VA
R
IE
S
SEE PLAN FOR SLOPE
1' -2
" M
IN
NOTE:
ALL ATTACHMENTS
1. #12 TEK SCREW FOR TRACK TO STUD @ 12" O.C.
2. 3/16"Ø TAPCON SCREWS FOR TRACK OR WOOD TO
MASONRY @ 12" O.C.
3. WOOD SCREWS FOR WOOD TO WOOD @ 12" O.C.
S-7
Project Name:
Drawing Title
AS NOTED
220601
04-28-26
EMS
FIRESTATION
NO.1 WIND
MITIGATION
CITY OF DANIA
BEACH
116 WEST DANIA
BEACH BLVD,
DANIA BEACH, FLORIDA
LN
LN
Design:
Job Number:
Drawing Number:
Date:
Checked:
Drawn:
Scale:
2211 NORTHEAST 54TH STREET
FORT LAUDERDALE, FLORIDA 33308
LAKDAS/YOHALEM ENGINEERING, INC.
(954)771-0630 FAX:(954)771-0519
FL. LIC.: CA-5458
CONSULTING ENGINEERS
ALL DRAWINGS AND WRITTEN
MATERIAL HEREIN, AS
INSTRUMENTS OF SERVICE,
SHALL REMAIN THE PROPERTY
OF LAKDAS/YOHALEM
ENGINEERING, INC. (LYE) AND
SHALL NOT BE REPRODUCED
OR COPIED, IN WHOLE OR IN
PART, WITHOUT THE
EXPRESSED WRITTEN CONSENT
OF "LYE" AND MAY NOT BE
USED OR REFERENCED FOR
ANY OTHER PROJECT.
INFORMATION CONTAINED
HEREIN REPRESENTS
PROPRIETARY INFORMATION OF
LAKDAS/YOHALEM ENGINEERING
INC. AND / OR ITS CLIENT
AND SHALL NOT BE DISCLOSED
TO OTHERS.
LAKDAS/YOHALEM ENGINEERING,
INC. SHALL BE AFFORDED THE
OPPORTUNITY TO PROVIDE
CONSTRUCTION OBSERVATION
SERVICES DURING THE FRAME
ERECTION OF THIS PROJECT. IN
THE EVENT LAKDAS/YOHALEM
ENGINEERING, INC. IS NOT
RETAINED IN THIS CAPACITY,
LAKDAS/YOHALEM ENGINEERING,
INC. CAN ASSUME NO
RESPONSIBILITY FOR THE
CONSTRUCTION DEFECTS FOR
THE RECOMMENDATIONS
PROVIDED IN THESE DOCUMENTS.
e-mail: lye@lyengineering.com
Revision
NO. Description Date
L A
K D
A S
N A N A Y A K
K A
R A
P R
O F
E
S S I O N A L E N G
I
N E
E R
S T
A T
E O F F L O
R I
D A
P.E. # 037590
DRY RUN
NOT FOR CONSTRUCTION
ELEVATIONS ARE IN NAVD 88
ROOFING DETAILS
OVERFLOW SCUPPER DETAIL2
S-7 SCALE: NTS
SECTION DETAIL1
S-7 SCALE: NTS
S-7 SCALE: NTS
EXISTING ROOFING EDGE AT ROOF #1
EXISTING ROOFING EDGE AT ROOF #3
EXISTING OVERFLOW AT OUTER SIDE WALL OF ROOF #1& #3
EXISTING ROOFING EDGE AT ROOF #2
TYPICAL SECTION DETAIL
NOTE:
CONDUCTOR HEAD IS SET MAXIMUM 4"
ABOVE LOW POINT OF SCUPPER TO
PROVIDE PRIMARY DRAINAGE &
EMERGENCY OVERFLOW DRAINAGE AT
THE SAME LOCATION.
CTRFLASHING TRIM
& FORM ENDCAPS @
SCUPPER OPENING
BASE FLASHING TRIM
@ SCUPPER OPENING
SEALANT @ SCUPPER TO
TILT PANEL
22 GA POWDER COATED
ALUMINUM SCUPPER W/
1/2" OUTER HEM & 4"
FULLY SOLDERED ROOF
FLANGE
24 GA POWDER COATED
ALUMINUM HEADER
MIN. 12 SQ IN, 26 GA POWDER
COATED ALUMINUM
DOWNSPOUT ANCHOR TO WALL
W/ 22 GA GALV STRAPS &
THREADED MASONRY
FASTENERS @ 10' O.C.
ELEV.:
L.P OF ROOF
(SEE ROOF PLAN)
4"
OVERFLOW OPENING
O
VE
R
FL
O W
O
PE
N
IN
G
EXISTING ROOF
STRUCTURE A PER
ROOF FRAMING PLAN
ROOF AS PER DETAIL
3/S-4
VULKEM PRIMER & SEALANT
CONT. 20 GA. ALUM. CAP FLASHING FASTENED
TO METAL CLEAT AND KEEPER STRIP
CONT. FIBER CANT STRIP
EXISTING ROOF
STRUCTURE A PER
ROOF FRAMING PLAN
SLOPE AS PER PLAN
EXISTING CONCRETE DOUBLE TEE
EXISTING CONCRETE TIE BEAM
PROVIDE CONT. BEAD OF
EXT. GRADE SEALANT.
24 GA. POWDER COATED ALUMINUM SPRINGLOCK
FLASHING FASTENED W/ HURRICANE CLIPS @ 36" O.C.
EXTEND BASE
ROOFING MEMBRANE
OVER PARAPET (TYP)
RE-ROOF WITH 4-PLYS TORCH DOWN BUILT-UP ROOFING
OVER R-19 TAPERED INSULATION ON EXISTING CONCRETE
DOUBLE TEE. ( ELEVATION MATCH WITH EXISTING)
NOTE:
VERIFY CONDITION OF EXISTING EXTERIOR
SUBSTRATE PRIOR TO RECOVERY BOARD
AND BASE SHEET INSTALLATION
6" V
IF
1'
-6 " V
IF
1' -2
" M
IN
WIRE LATH W/ 5/8" MIN. STUCCO
EXISTING WOOD FRAME
RE-ROOF WITH 4-PLYS TORCH
DOWN BUILT-UP ROOFING OVER
R-19 TAPERED INSULATION ON
EXISTING 5/8" EXTERIOR GRADE
APA PLYWOOD DECK
ELEV.:
T.O EXISTING PARAPET
=+16-0" VIF
8" M
IN
2' -0
1 2" V
IF
SLOPE (SEE NEW ROOF PLAN)
S-8
1' -2
" M
IN
CONT. 12" WIDE -18 GAUGE
GALVANIZED METAL
STUD @ 16" O.C.
1'-10" (VIF)
CONT. 2"x8" P.T. WOOD
EXISTING WOOD FRAME
TAPCON @ 6" O.C STAGGERED
SLOPE
CONT. 12" WIDE-18 GAUGE
GALVANIZED BOTTOM TRACK
CONT. 2"x12" P.T. WOOD
CONT. 12" WIDE-18 GAUGE
GALVANIZED TOPTRACK
EXISTING CONCRETE DOUBLE TEE
ELEV.:
T.O EXISTING SLAB
=+15'-6" VIF
CONT. 10" WIDE -18 GAUGE
GALVANIZED METAL STUD @ 16" O.C.
CONT. 2"x8" P.T. WOOD
CONT. 10" WIDE-18 GAUGE GALVANIZED
BOTTOM TRACK
CONT. 2"x10" P.T. WOOD
CONT. 10" WIDE-18 GAUGE
GALVANIZED TOP TRACK
8" M
IN
VA
R
IE
S
NOTE:
ALL ATTACHMENTS
1. #12 TEK SCREW FOR TRACK TO STUD @ 12" O.C.
2. 3/16"Ø TAPCON SCREWS FOR TRACK OR WOOD TO
MASONRY @ 12" O.C.
3. WOOD SCREWS FOR WOOD TO WOOD @ 12" O.C.
10"1'-0"
S-8
Project Name:
Drawing Title
AS NOTED
220601
04-28-26
EMS
FIRESTATION
NO.1 WIND
MITIGATION
CITY OF DANIA
BEACH
116 WEST DANIA
BEACH BLVD,
DANIA BEACH, FLORIDA
LN
LN
Design:
Job Number:
Drawing Number:
Date:
Checked:
Drawn:
Scale:
2211 NORTHEAST 54TH STREET
FORT LAUDERDALE, FLORIDA 33308
LAKDAS/YOHALEM ENGINEERING, INC.
(954)771-0630 FAX:(954)771-0519
FL. LIC.: CA-5458
CONSULTING ENGINEERS
ALL DRAWINGS AND WRITTEN
MATERIAL HEREIN, AS
INSTRUMENTS OF SERVICE,
SHALL REMAIN THE PROPERTY
OF LAKDAS/YOHALEM
ENGINEERING, INC. (LYE) AND
SHALL NOT BE REPRODUCED
OR COPIED, IN WHOLE OR IN
PART, WITHOUT THE
EXPRESSED WRITTEN CONSENT
OF "LYE" AND MAY NOT BE
USED OR REFERENCED FOR
ANY OTHER PROJECT.
INFORMATION CONTAINED
HEREIN REPRESENTS
PROPRIETARY INFORMATION OF
LAKDAS/YOHALEM ENGINEERING
INC. AND / OR ITS CLIENT
AND SHALL NOT BE DISCLOSED
TO OTHERS.
LAKDAS/YOHALEM ENGINEERING,
INC. SHALL BE AFFORDED THE
OPPORTUNITY TO PROVIDE
CONSTRUCTION OBSERVATION
SERVICES DURING THE FRAME
ERECTION OF THIS PROJECT. IN
THE EVENT LAKDAS/YOHALEM
ENGINEERING, INC. IS NOT
RETAINED IN THIS CAPACITY,
LAKDAS/YOHALEM ENGINEERING,
INC. CAN ASSUME NO
RESPONSIBILITY FOR THE
CONSTRUCTION DEFECTS FOR
THE RECOMMENDATIONS
PROVIDED IN THESE DOCUMENTS.
e-mail: lye@lyengineering.com
Revision
NO. Description Date
L A
K D
A S
N A N A Y A K
K A
R A
P R
O F
E
S S I O N A L E N G
I
N E
E R
S T
A T
E O F F L O
R I
D A
P.E. # 037590
DRY RUN
NOT FOR CONSTRUCTION
ELEVATIONS ARE IN NAVD 88
ROOFING DETAILS
TYPICAL SECTION DETAIL1
S-8 SCALE: NTS
OVERFLOW SCUPPER DETAIL3
S-8 SCALE: NTS
EXISTING OVERFLOW SCUPPER @ ROOF #2
EXISTING ROOFING BETWEEN ROOF #2 & #3
EXISTING ROOFING BETWEEN ROOF #1 & #2
EXISTING OVERFLOW SCUPPER @ ROOF #2
BID SET 04-28-2026
TYPICAL DETAIL SECTION ( FRAMING)2
S-8 SCALE: NTS
EXISTING ROOF
STRUCTURE A PER
ROOF FRAMING PLAN
2'-3"
2'-0"
3/4"x 2-1/2" ALUMINUM
LADDER ATTACHED TO
EXTERIOR FACE OF WALL W/
2- 2" X 3/16" ALUMINUM WALL
BRACKETS. ATTACH TO TILT
WALL W/ 3/16" x 4" TAPCON
FASTENERS
O
VE
R
AL
L
LA
D D
ER
H
EI
G
H T
- V
IF
VA
R
IE
S
1' -0
(M
AX
6"x8"x1/4"ALUMINUM
PLATE WITH (4)
TAPCON
WELD TO BASE
PLATE
8" M
IN
O
VE
R
AL
L
LA
D D
ER
H
EI
G
H T
(V
ER
IF
Y)
F.
T
O T
O P
O F
PA
R
AP
ET
2'-71 2"
8' -0
4'
-0
4' -0
VA
R
IE
S
TO
P H
O O
P
3' -6
3' -7
1 2"
2'-0"
1' -0
(T
YP
TYP. ALUMINUM SERRATED
RUNGS 1 1/4"Ø
4" X 1 3/8" X 3/16" 2" LG.
ALUM. ANGLE FLOOR
BRACKET
3/16" AL. WALL
BRACKET
SAFETY END
CAP
VARIES
EXISTING
MASONRY WALL
EXISTING TIE
BEAM (VIF)
M
IN
.8
POURABLE SEALER
SHAPED TO SHED
WATER.
3" MIN.
2" M
IN
. 1"
EXISTING ROOF
STRUCTURE A PER
ROOF FRAMING PLAN
FLASHING CLAMP
DEVICE & GRAVEL
STOP
FELT STRIPPING
4 # MIN. LEAD
FLASHING FLANGE
(8" MIN.) SET IN
FLASHING CEMENT
R.W.L. ROOF FILL SEE
ROOF SPECS
SLOPE 1/8" TO 1'-0"
STRAINER
SLOPE 1/8" TO 1'-0"
MIN. 12 SQ IN
REQUIREMENT
1/4" GALVANIZED SHEET
PLATE WELDED TO 1.5"
22 GAUGE DECK W/ 1/8"
FILLED WELD W/ 1/4" Ø -
2" LONG TAPCON
SCREW @ 8" O.C
48" MAX - VIF
LIGHTWEIGHT CONCRETE FILL, 200 PSI
SUPPORTED ON 1-1/2" 22 GAUGE, TYPE B
AS MANUFACTURED BY "VULCRAFT" OR
APPROVED EQUAL,
EXISTING DOUBLE
TEE (TYP)
CL CL
1/4" GALVANIZED SHEET
PLATE WELDED TO 1.5"
22 GAUGE DECK W/ 1/8"
FILLED WELD W/ 1/4" Ø -
2" LONG TAPCON
SCREW @ 8" O.C
EXISTING DOUBLE
TEE (TYP)
1/4" Ø - 2" LONG TAPCON
SCREW @ 8" O.C (TYP)
1/4" GALVANIZED SHEET
PLATE WELDED TO 1.5" 22
GAUGE DECK W/ 1/8"
FILLED WELD
1-1/2" 22 GAUGE,
TYPE B AS
MANUFACTURED
BY "VULCRAFT" OR
APPROVED EQUAL,
NEW ROOFING
13 1/2"
SAFETY HOOPS
STANDARD
1" X 3" X 1/8" ALUM. FRAME ALLOY
6063-T5
1 1/4" X 4 1/8" ALUM. SERRATED
TREAD ALLOY 6061-T6
2' -0
2' -3
2'-7"
13 1/2"
2'-0"
9" 1"
1" 7"
11 4"
43 4"
1" 33 4"
3 4"
(L
AD
D
ER
W
ID
TH
43 4"
1" 33 4"
2"
9 16
7"
2"
3/16" EXTRUDED
ALUMINUM BRACKET
ALLOY 6061-T6 ONE
EACH SIDE
(2) 1/4" X 3/4" S.S.
BOLT WITH
NUT & LOCK
WASHER
(2) 5/8" S.S.
EPOXY (SIKADUR
EPOXY GEL)
BOLTS
NL-1 ALUM. EXTRUDED
LADDER RAIL ALLOY
6063-T5
NL-2 EXTRUDED
ALUMINUM COVER
PLATE ALLOY 6063-T5
NL-2 EXTRUDED ALUMINUM
CHANNEL RAIL ALLOY 6063-T5
(2) #12 X 1 1/2" H.H. S.S. SELF
TAPPING SCREW AT EACH END
(2) 1/4" X 3/4" S.S.
BOLT W/NUT AND
L.W.
(2) 7/16"Ø HOLE FOR (2) 3/8" S.S.
ANCHOR BOLTS
3/16" EXTRUDED
ALUMINUM BRACKET
ALLOY 6061-T6 ONE
EACH SIDE
(2) 5/8" S.S. EPOXY
(SIKADUR EPOXY
GEL) BOLTS
(2) 1/4" X 3/4" S.S.
BOLT W/NUT
AND L.W.
7"
MINIMUM
NL-1 EXTRUDED
ALUMINUM CHANNEL
RAIL ALLOY 6063-T5
(2) #12 X 1 1/2" H.H.
S.S. SELF TAPPING
SCREW AT EACH END
1 1/4" SQ. EXTRUDED
ALUM. SERRATED RUNG
ALLOY 6061-T6
S-9
Project Name:
Drawing Title
AS NOTED
220601
04-28-26
EMS
FIRESTATION
NO.1 WIND
MITIGATION
CITY OF DANIA
BEACH
116 WEST DANIA
BEACH BLVD,
DANIA BEACH, FLORIDA
LN
LN
Design:
Job Number:
Drawing Number:
Date:
Checked:
Drawn:
Scale:
2211 NORTHEAST 54TH STREET
FORT LAUDERDALE, FLORIDA 33308
LAKDAS/YOHALEM ENGINEERING, INC.
(954)771-0630 FAX:(954)771-0519
FL. LIC.: CA-5458
CONSULTING ENGINEERS
ALL DRAWINGS AND WRITTEN
MATERIAL HEREIN, AS
INSTRUMENTS OF SERVICE,
SHALL REMAIN THE PROPERTY
OF LAKDAS/YOHALEM
ENGINEERING, INC. (LYE) AND
SHALL NOT BE REPRODUCED
OR COPIED, IN WHOLE OR IN
PART, WITHOUT THE
EXPRESSED WRITTEN CONSENT
OF "LYE" AND MAY NOT BE
USED OR REFERENCED FOR
ANY OTHER PROJECT.
INFORMATION CONTAINED
HEREIN REPRESENTS
PROPRIETARY INFORMATION OF
LAKDAS/YOHALEM ENGINEERING
INC. AND / OR ITS CLIENT
AND SHALL NOT BE DISCLOSED
TO OTHERS.
LAKDAS/YOHALEM ENGINEERING,
INC. SHALL BE AFFORDED THE
OPPORTUNITY TO PROVIDE
CONSTRUCTION OBSERVATION
SERVICES DURING THE FRAME
ERECTION OF THIS PROJECT. IN
THE EVENT LAKDAS/YOHALEM
ENGINEERING, INC. IS NOT
RETAINED IN THIS CAPACITY,
LAKDAS/YOHALEM ENGINEERING,
INC. CAN ASSUME NO
RESPONSIBILITY FOR THE
CONSTRUCTION DEFECTS FOR
THE RECOMMENDATIONS
PROVIDED IN THESE DOCUMENTS.
e-mail: lye@lyengineering.com
Revision
NO. Description Date
L A
K D
A S
N A N A Y A K
K A
R A
P R
O F
E
S S I O N A L E N G
I N
E E
R
S T
A T
E O F F L O
R I
D A
P.E. # 037590
DRY RUN
NOT FOR CONSTRUCTION
ELEVATIONS ARE IN NAVD 88
ACCESS LADDER
AND ROOF
PENETRATION
ROOF ACCESS LADDER1
S-9 SCALE: NTS
ROOF PENETRATION4
S-9 SCALE: NTS
DRAIN DETAIL3
S-9 SCALE: NTS
FRONT ELEVATION SIDE ELEVATION
SECTION DETAIL5
S-9 SCALE: NTS
ROOF ACCESS LADDER2
S-9 SCALE: NTS
FLATFORM PLAN
REFERENCE PHOTO
REFERENCE PHOTO ( ACCESS HATCH TO BE REMOVED
REFERENCE PHOTO
REFERENCE PHOTO
TOP BRACKET - TOP VIEWTOP BRACKET - SIDE VIEW
BID SET 04-28-2026
AutoCAD SHX Text C
AutoCAD SHX Text
ROOF PENETRATION
AutoCAD SHX Text
PENETRATION PAN
AutoCAD SHX Text
CEMENTITIOUS FILL
AutoCAD SHX Text
E.P.D.M. FORMFLASH
AutoCAD SHX Text
APPROVED FASTENER
AutoCAD SHX Text
WATER BLOCK
AutoCAD SHX Text
LAP SEALENT
VEHICLE BAY
BLDG.
EQUIPMENT
BLDG.
8.7'8.7'
8.
7'
8.
7'
2.
9'
2.
9'
8.
7'
8.
7'
2.
9'
2.
9'
2.9'
2.9'
8.
7'
8.
7'
2.9'
2.9'
8.7'
8.7'
DORMITORY
BLDG.
8.4' 8.4'
2.
8'
2.
8'
2.
8'
2.
8'
3.1'
3.
1'
9.
3'
9.3'
2 2
3.1'
3.
1'
9.
3'
3.1'
3.
1'
3.
1'
3.1'
9.3' 9.3'
9.
3'
9.
3'
NORTH
S-10
Project Name:
Drawing Title
AS NOTED
220601
04-28-26
EMS
FIRESTATION
NO.1 WIND
MITIGATION
CITY OF DANIA
BEACH
116 WEST DANIA
BEACH BLVD,
DANIA BEACH, FLORIDA
LN
LN
Design:
Job Number:
Drawing Number:
Date:
Checked:
Drawn:
Scale:
2211 NORTHEAST 54TH STREET
FORT LAUDERDALE, FLORIDA 33308
LAKDAS/YOHALEM ENGINEERING, INC.
(954)771-0630 FAX:(954)771-0519
FL. LIC.: CA-5458
CONSULTING ENGINEERS
ALL DRAWINGS AND WRITTEN
MATERIAL HEREIN, AS
INSTRUMENTS OF SERVICE,
SHALL REMAIN THE PROPERTY
OF LAKDAS/YOHALEM
ENGINEERING, INC. (LYE) AND
SHALL NOT BE REPRODUCED
OR COPIED, IN WHOLE OR IN
PART, WITHOUT THE
EXPRESSED WRITTEN CONSENT
OF "LYE" AND MAY NOT BE
USED OR REFERENCED FOR
ANY OTHER PROJECT.
INFORMATION CONTAINED
HEREIN REPRESENTS
PROPRIETARY INFORMATION OF
LAKDAS/YOHALEM ENGINEERING
INC. AND / OR ITS CLIENT
AND SHALL NOT BE DISCLOSED
TO OTHERS.
LAKDAS/YOHALEM ENGINEERING,
INC. SHALL BE AFFORDED THE
OPPORTUNITY TO PROVIDE
CONSTRUCTION OBSERVATION
SERVICES DURING THE FRAME
ERECTION OF THIS PROJECT. IN
THE EVENT LAKDAS/YOHALEM
ENGINEERING, INC. IS NOT
RETAINED IN THIS CAPACITY,
LAKDAS/YOHALEM ENGINEERING,
INC. CAN ASSUME NO
RESPONSIBILITY FOR THE
CONSTRUCTION DEFECTS FOR
THE RECOMMENDATIONS
PROVIDED IN THESE DOCUMENTS.
e-mail: lye@lyengineering.com
Revision
NO. Description Date
L A
K D
A S
N A N A Y A K
K A
R A
P R
O F
E
S S I O N A L E N G
I N
E E
R
S T
A T
E O F F L O
R I
D A
P.E. # 037590
DRY RUN
NOT FOR CONSTRUCTION
ELEVATIONS ARE IN NAVD 88
ROOF DESIGN WIND
PRESSURES AND
GENERAL NOTES
ROOF DESIGN WIND PRESSURES1
S-10 SCALE: NTS
ZONE 1 ZONE 2 ZONE 3
DORMITORY
BLDG.
+28
WIND PRESSURES
ZONE 1 ZONE 2 ZONE 3
PRESSURES (PSF)
(ULTIMATE)
PRESSURES (PSF)
(ALLOWABLE)
-108
+28
-143
+28
-191
VEHICLE BAY
BLDG.
EQUIPMENT
BLDG.
BUILDING
+17
-65
+17
-86
+17
-115
+28
-108
+28
-143
+28
-191
+17
-65
+17
-86
+17
-115
+28
-109
+28
-144
+28
-188
+17
-66
+17
-87
+17
-113
BID SET 04-28-2026
GENERAL NOTES:
1. ALL ALUMINUM AND ACCESORIES SHALL COMPLY WITH THE FOLLOWING
CODES:
FLORIDA BUILDING CODE (FBC) 2023 (8th EDITION), AND ASCE 7-22.
LOADING
DEAD LOAD = 15 PSF
LIVE LOAD = 25 PSF
MISCELANEOUS = 10 PSF
50 PSF
ROOF DESIGN LOADS (SIMILAR AS FLOOR PLAN FOR FUTURE USE)
DEAD LOAD = 91 PSF
SUPERIMPOSED DEAD = 25 PSF
LIVE LOAD = 30 PSF
WIND
WIND SPEED = 187 MPH
EXPOSED = C
CATEGORY = III
2. BUILT-UP ROOF SHALL HAVE BUILT-UP ROOFS SHALL HAVE A DESIGN SLOPE
OF NOT LESS THAN ONE-FOURTH UNIT VERTICAL IN 12 UNITS HORIZONTAL
(2-PERCENT SLOPE) FOR DRAINAGE, EXCEPT FOR COAL-TAR BUILT-UP
ROOFS THAT SHALL HAVE A DESIGN SLOPE OF NOT LESS THAN ONE-EIGHTH
UNIT VERTICAL IN 12 UNITS HORIZONTAL (1-PERCENT SLOPE)
3. RER MATERIAL STANDARDS. BUILT-UP ROOF COVERING MATERIALS SHALL
COMPLY WITH THE STANDARDS IN TABLE 1507.10.2 OR UL 55A.
TABLE 1507.10.2
BUILT-UP ROOFING MATERIAL STANDARDS
ASPHALT-COATED GLASS FIBER BASE SHEET ASTM D4601
ASPHALT COATINGS USED IN ROOFING ASTM D1227; D2823; D2824;
D4479
ASPHALT GLASS FELT ASTM D2178
ASPHALT PRIMER USED IN ROOFING A STM D41
ASPHALT-SATURATED AND ASPHALT-COATED
ORGANIC FELT BASE SHEET ASTM D2626
COAL-TAR PRIMER USED IN ROOFING,
DAMPPROOFING AND WATERPROOFING ASTM D43
GLASS MAT, VENTING TYPE ASTM D4897
MINERAL-SURFACED INORGANIC CAP SHEET ASTM D3909
4. MODIFIED BITUMEN ROOFCOVERINGS SHALL COMPLY WITH ASTM D6162,
ASTM D6163, ASTM D6164, ASTM D6222, ASTM D6223, ASTM D6298 OR ASTM
D6509.
CONCRETE:
1 CONCRETE ELEMENTS TO HAVE THE FOLLOWING STRENGTHS:
A FOUNDATIONS 4000 PSI
B STRUCTURAL SLAB ON GRADE 4000 PSI
C COLUMNS 4000 PSI
D GRADE BEAMS 4000 PSI
E TIE BEAMS 4000 PSI
F STRUCTURAL BEAMS 4000 PSI
G STRUCTURAL SLABS 4000 PSI
H MASONRY GROUT 3000 PSI
ALL OTHER CONCRETE TO BE 3000 PSI UNLESS NOTED OTHERWISE.
2 ALL CONCRETE SHALL BE READY MIX, HAVE A MINIMUM COMPRESSIVE STRENGTH OF :
A 3000 PSI @28 DAYS AND HAVE A MINIMUM OF 517 LBS. OF CEMENT PER CUBIC YARD.
B SLUMPS SHALL BE 3 MINIMUM AND 5 MAXIMUM.
C CONCRETE SHALL HAVE 3 +/- 1.5 PERCENT AIR ENTRAINMENT.
D ALL CONCRETE TO HAVE MAXIMUM WATER/CEMENT RATIO OF 0.55.
E JOB SITE WATER SHALL NOT BE ADDED.
3 ALL CONCRETE WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE ACI BUILDING CODE (ACI 318 / LATEST EDITION), THE ACI DETAILING MANUAL (ACI 315 / LATEST EDITION), AND THE SPECIFICATIONS FOR
STRUCTURAL CONCRETE FOR BUILDINGS (ACI 301 / LATEST EDITION).
4 SUBMIT ALL REINFORCING STEEL SHOP DRAWINGS FOR APPROVAL PRIOR TO ANY FABRICATION.
5 WELDED WIRE FABRIC SHALL COMPLY WITH ASTM A 185, UNLESS OTHERWISE SPECIFIED. PLACE FABRIC 2" CLEAR FROM TOP OF THE SLAB IN SLAB ON GRADE AND SUPPORT ON SLAB BOLSTERS SPACED
AT 3'-0" ON CENTER.
6 REQUIREMENTS:
A ALL REINFORCING STEEL SHALL BE MANUFACTURED FROM HIGH STRENGTH BILLET
STEEL CONFORMING TO ASTM DESIGNATION A 615 GRADE 60.
B W.W.F. SHALL COMPLY WITH ASTM A 185.
7 LAP ALL BARS MINIMUM 48 DIAMETERS UNLESS OTHERWISE NOTED ON DRAWINGS. LAP ALL W.W.F.
A MINIMUM OF 6" UNLESS OTHERWISE NOTED.
8 REINFORCING BARS:
A AT CORNERS OF CONCRETE WALLS, BEAMS AND CONTINUOUS WALL FOOTINGS, PROVIDE
(1)-#5 X 5'-0" BENT BAR FOR EACH HORIZONTAL BAR SCHEDULED AT EACH FACE.
B WHERE COLUMNS ARE AN INTEGRAL PART OF CONCRETE WALLS, WALL REINFORCEMENT
SHALL BE CONTINUOUS THRU THE COLUMNS.
C ALL HOOKS SHOWN IN REINFORCEMENT SHALL BE ACI RECOMMENDED HOOKS UNLESS
OTHERWISE NOTED.
9 CONSTRUCTION JOINTS IN STRUCTURAL SLABS AND BEAMS SHALL BE AT MID-SPAN AND KEY
JOINTED WITH REINFORCING CONTINUOUS ACROSS JOINT, ADDITIONAL SHEAR FRICTION REINFORCING.
11 CONCRETE COVER FOR REINFORCING STEEL SHALL BE AS REQUIRED BY THE ACI 318-19
STANDARD.
A FLOOR - 11
2"
B STRUCTURAL BEAMS - 11
2"
C R/C COLUMNS - 2"
D COLUMN W/WALL - 2"
E GRADE BEAMS - 3 "
F PILES - 3"
MASONRY:
1 ALL MORTAR SHALL BE TYPE S OR TYPE M, IN
ACCORDANCE WITH ASTM SPECIFICATION C270
WITH A MINIMUM COMPRESSIVE STRENGTH OF
1,800 PSI AT 28 DAYS, (2,500 WITH TYPE M), FROM
FIELD OBTAINED TEST CUBES. (MIN. OF TWO) FILL
ALL MASONRY WALL BELOW FIRST LEVEL TO
FOUNDATION.
2 GROUT SHALL BE A HIGH SLUMP MIX IN
ACCORDANCE WITH ASTM SPECIFICATION C476
HAVING A MINIMUM COMPRESSIVE STRENGTH OF
3,000 PSI FROM FIELD OBTAINED TEST CUBES,
(MIN. OF TWO).
3 LAP ALL BARS MINIMUM 48 BAR DIAMETERS
UNLESS OTHERWISE NOTED ON DRAWINGS.
GENERAL NOTES2
S-10 SCALE: NTS
SL
O
PE
SL
O
PE
SL
O
PE
CORE 02
CORE 01
CORE…