2026-026B Drawings.pdf
PDF 8 MB Posted
- Attached to
- Valentine Early Learning Facility Improvements
- Solicitation number
- 2026-026B
- Issued by
- Calhoun County, Michigan
About this file
This document is a comprehensive architectural design and renovation set of plans for the Valentine Center, located at 75 Irving Park Dr, Battle Creek, MI 49037. The project involves renovating an existing brick educational building, with the scope of work covering approximately 7,107 square feet, which represents 93% of the total building area. The renovation is classified as a Level 3 Alteration, which requires compliance with specific Michigan Rehabilitation Code standards. The project includes significant upgrades to interior spaces, including classrooms, restrooms, kitchen, office areas, and mechanical systems, with a focus on creating a functional child care and educational environment.
The design includes multiple alternate options for consideration, such as replacing existing glazing, tuckpointing masonry, and adding an extended canopy. The renovation will maintain the building's historic character while modernizing its functionality, with careful attention to accessibility requirements, fire safety, and energy efficiency. The plans detail specific improvements to finishes, lighting, electrical and plumbing systems, and spatial configurations. The project appears to be funded through institutional or governmental sources, with provisions for maintaining the building's existing infrastructure while making significant improvements to create a more modern and efficient educational space.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 2026-026B Valentine Center Early Learning Facility Improvements.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
© 2024 Driven Design Studio, All Rights Reserved.
Driven Design Studio PLLC
117 West Michigan Avenue
Battle Creek, MI 49017
(269) 753-8040 cody@drivendesignstudio.com
PROJECT NUMBER
STAMP
SCALE
DATE
DRAWN BY
PROJECT ADDRESS
PROJECT NAME
ARCHITECTURE/INTERIOR DESIGN
THIS DOCUMENT IS THE EXCLUSIVE
PROPERTY OF DRIVEN DESIGN. THE
DOCUMENT & THE INFORMATION IT
CONTAINS MAY NOT BE REPRODUCED
OR USED FOR OTHER THAN THE
SPECIFIC PROJECT FOR WHICH IT WAS
PREPARED WITHOUT THE EXPLICIT
CONSENT OF DRIVEN DESIGN.
OWNER
ISSUE
10/17/2025 9:32:36 AM
T000
TITLE SHEET
VALENTINE CENTER
75 IRVING PARK DR, BATTLE CREEK, MI
49037
CMN
VALENTINE CENTER
75 IRVING PARK DR, BATTLE CREEK, MI 49037
2025.024
City of Battle Creek
10 N Division St
Battle Creek, MI
(269) 966-3355
CONSTRUCTION DOCUMENTS
X
PROJECT NOTES
1. CONSTRUCTION MUST COMPLY WITH ALL NATIONAL, STATE, AND LOCAL BUILDING CODES,
AS WELL AS ALL LOCAL ORDINANCES.
2. DO NOT SCALE DRAWINGS. NOMINAL DIMENSIONS ARE SHOWN. REFER TO DETAILS, NOTES,
SPECIFICATIONS AND PARTITION KEY FOR INFORMATION. CONTACT ARCHITECT IF
ADDITIONAL INFORMATION IS REQUIRED.
3. EXISTING BUILDING AND SITE INFORMATION WAS OBTAINED FROM THE OWNER AND
ADDITIONAL FIELD MEASUREMENTS BY THE ARCHITECT. THE CONTRACTOR SHALL VERIFY ALL
EXISTING FIELD CONDITIONS PRIOR TO COMMENCEMENT OF WORK. DRAWINGS MAY
CONTAIN DISCREPANCIES DUE TO CONCEALED CONDITIONS, INACCURACIES IN THE
ORIGINAL DRAWINGS, INACCESSIBLE LOCATIONS, UNRECORDED BUILDING ALTERATIONS
AND OTHER CONFLICTING INFORMATION. INFORMATION OUTSIDE OF CONTRACT AREA IS
RELATIVE AND FOR REFERENCE ONLY. ALWAYS VERIFY FIELD CONDITIONS BEFORE
COMMENCING WORK. NOTIFY ARCHITECT IF FIELD CONDITIONS CONFLICT SUBSTANTIALLY
WITH PROPOSED WORK.
4. INSTRUCTIONS FOR BUILDING CONSTRUCTION MAY BE LOCATED IN ANY PART OF THE
CONSTRUCTION DRAWINGS. FAILURE OF THE GENERAL CONTRACTOR OR HIS SUB
CONTRACTORS AND SUPPLIERS TO SEE INFORMATION IN ANY PART OF THE CONTRACT
DOCUMENTS WILL NOT BE A VALID REASON FOR ISSUING A CHANGE ORDER.
5. ALL HOLES CREATED FROM ABANDONED DUCT, CONDUIT, ELEC. DEVICES, ETC., WHICH ARE
IN VIEW AND ARE NOT SCHEDULED TO BE BOARDED OVER, OR ON A WALL TO BE
DEMOLISHED, ARE TO BE FILLED AND PATCHED TO MATCH EXISTING.
6. PATCH AND REPAIR ALL EXISTING WALL SURFACES ADJACENT TO NEW WORK AS REQUIRED
TO ACHIEVE AN UNINTERRUPTED SURFACE APPEARANCE. PATCH AND REPAIR ALL FLOORING
FOR EXISTING BUILDINGS TO ACHIEVE A CONTINUOUS, SMOOTH, AND FLUSH FLOOR
SURFACE.
7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SHORING REQUIRED TO EXECUTE WORK.
THE CONTRACTOR SHALL COORDINATE ALL TEMPORARY CONSTRUCTION WITH THE
ARCHITECT AND OWNER TO ASSURE A MINIMUM AMOUNT OF INTERRUPTION WITH THE
OWNER'S ACTIVITIES.
8. IF THE PROJECT IS A REMODEL, THE CONTRACTOR IS RESPONSIBLE FOR PROTECTING ALL
SURFACES NOT BEING REMODELED IN THE PROJECT AND IN THE PATH OF THE CONTRACTORS
TRAVEL, SETUP AND/ OR PROJECT MATERIAL STORAGE. THE CONTRACTOR MUST RETURN THE
AREAS DISTURBED AS REQUIRED FOR ACCESS TO ITS PRE-EXISTING CONDITION.
9. THE CONTRACTOR AND ALL SUB-CONTRACTORS SHALL BE RESPONSIBLE TO OBTAIN AND PAY
FOR ALL LOCAL/REQUIRED PERMITS AND INSPECTIONS.
10. ALL SAFETY ISSUES RELATED TO CONSTRUCTION ARE THE RESPONSIBILITY OF THE
CONTRACTOR AND MUST COMPLY WITH ALL STATE, LOCAL, ENVIRONMENTAL AND LABOR
LAWS DURING THE CONSTRUCTION OF THIS PROJECT.
11. ALL WORK TO BE GUARANTEED A MINIMUM OF ONE YEAR FROM THE DATE OF OWNER
ACCEPTANCE OF WORK, EXCEPT WHERE MANUFACTURER'S GUARANTEE IS LONGER.
12. IF DISCREPANCIES OCCUR BETWEEN DRAWINGS AND FIELD CONDITIONS CONTACT THE
ARCHITECT TO VERIFY HOW TO PROCEED BEFORE DOING SO.
13. SEE T001 FOR ADDITIONAL PROJECT NOTES, MOUNTING HEIGHTS, AND SYMBOLS
14. 3D VIEWS AND RENDERINGS ON THIS PAGE AND THROUGHOUT THE SET ARE FOR REFERENCE
ONLY, VERIFY ALL CONSTRUCTION DETAILS THROUGHOUT THE ENTIRE SET OF DOCUMENTS
15. THE PROJECT SHALL CONFORM TO UNDERWRITERS LABORATORY FIRE RESISTANCE DIRECTORY
AND BUILDING MATERIALS DIRECTORY.
16. ANY MATERIAL SUBSTITUTIONS TO A LISTED UL DESIGN NUMBER SHALL BE COORDINATED BY
THE CONSTRUCTION MANAGER, CONTRACTOR, SUBCONTRACTOR AND/OR MATERIAL
SUPPLIER FOR COMPLIANCE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL
APPROVALS - FOR ANY MATERIALS SUBSTITUTION IN THE REQUIRED UL DESIGN ASSEMBLY - BY
THE FIRE MARSHAL AND BUILDING INSPECTOR HAVING JURISDICTION PRIOR TO
ACCEPTANCE.
17. FOR ANY CHANGE OF UL DESIGN NUMBER, OR ANY CHANGE IN MATERIAL(S) IN A UL DESIGN
ASSEMBLY, IT WILL BE THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE ALL OTHER
RELATED MATERIALS OR ASSEMBLIES AFFECTED BY THE CHANGE OF MATERIAL OR UL DESIGN
NUMBER ASSEMBLY.
18. PROVIDE COMPLETE UL APPROVED THROUGH-PENETRATION FIRESTOP SYSTEMS AT ALL RATED
WALL PENETRATIONS.
19. PROVIDE FIRESTOPPING AS REQUIRED AT ALL OPENINGS FOR PLUMBING, CONDUIT,
DUCTWORK, ETC AT FIRE RATED ASSEMBLIES.
20. REFER TO THE FLOOR PLANS FOR IDENTIFICATION OF ALL FIRE AND SMOKE-RATED PARTITIONS.
SHEET
NUMBER DRAWING TITLE 3
/1
/2
D
E S
IG
N D
E V
E
LO
P M
E N
T
/1
/2
P
E R
M
IT
S E T
GENERAL
T000 TITLE SHEET X X
T001 RENDERINGS X X
T002 GENERAL MOUNTING HEIGHTS + ABBREVIATIONS X X
T003 PLUMBING MOUNTING HEIGHTS X X
T004 CODE COMPLIANCE - REHAB CODE X X
T005 CODE COMPLIANCE X X
T006 AREA PLANS X X
T007 SECURITY PLAN X X
CIVIL
C100 ARCHITECTURAL SITE PLAN AND DETAILS X X
ARCHITECTURAL
A000 EXISTING FLOOR PLANS X X
A110 DEMOLITION PLANS X X
A120 NEW FLOOR PLANS X X
A130 ENLARGED PLANS X X
A140 FINISH PLAN & SCHEDULE X X
A200 REFLECTED CEILING PLAN AND DETAIL X X
A210 ROOF PLAN X X
A300 INTERIOR ELEVATIONS X X
A310 INTERIOR DETAILS X X
A400 DOOR SCHEDULE X X
A410 GLAZING ELEVATIONS AND SECTIONS X X
A500 EXTERIOR ELEVATIONS X X
A600 BUILDING SECTIONS X X
MECHANICAL
MEP101 MECH, ELEC, PLUMB SPECS/NOTES X X
Grand total: 23
EXISTING PHOTOS - FOR REFERENCE ONLY
ZONING - GRN - GREEN DISTRICT
CONTEXT MAP
DRAWING LIST
PROJECT DESCRIPTION
AN EXISTING BRICK EDUCATIONAL BUILDING IS BEING RENOVATED INTO A DAYCARE
ZONING MAP
RENDERING - FOR REFERENCE ONLY
PROJECT LOCATION
PROJECT LOCATION
WALTER AVE
M
IL
E R
D
ALTERNATES
THE FOLLOWING ITEMS ARE TO BE BID OUT AS ALTERNATES;
1. BASIS OF DESIGN: THE EXISTING ENTRYWAY IS TO BE PAINTED, ALTERNATE: PROVIDE THE PRICE
FOR THE NEW STEEL CANOPY
2. BASIS OF DESIGN: PAINT OR REPAIR EXISTING CEILINGS IN ROOMS 106, 107, 109, 115,116, &
117, ALTERNATE: REPLACE EXISTING CEILINGS WITH NEW CEILINGS
3. BASIS OF DESIGN: EXISTING EXTERIOR GLAZING TO REMAIN, ALTERNATE: REPLACE ALL
EXISTING EXTERIOR GLAZING
4. BASIS OF DESIGN: EXISTING MASONRY TO REMAIN, ALTERNATE: TUCKPOINT EXISTING
MASONRY
5. BASIS OF DESIGN: RELOCATE OFFICE DOOR 103, ALTERNATE, LEAVE IN EXISTING LOCATION
Headquarters Driven Design
117 West Michigan Avenue
Battle Creek, MI 49017
(269) 753-8040 cody@drivendesignstudio.com
PROJECT NUMBER
STAMP
SCALE
DATE
DRAWN BY
PROJECT ADDRESS
PROJECT NAME
ARCHITECTURE/INTERIOR DESIGN
THIS DOCUMENT IS THE EXCLUSIVE
PROPERTY OF DRIVEN DESIGN. THE
DOCUMENT & THE INFORMATION IT
CONTAINS MAY NOT BE REPRODUCED
OR USED FOR OTHER THAN THE
SPECIFIC PROJECT FOR WHICH IT WAS
PREPARED WITHOUT THE EXPLICIT
CONSENT OF DRIVEN DESIGN.
OWNER
ISSUE
10/17/2025 9:32:36 AM
T001
RENDERINGS
VALENTINE CENTER
75 IRVING PARK DR, BATTLE CREEK, MI
49037
CMN
2025.024
City of Battle Creek
10 N Division St
Battle Creek, MI
(269) 966-3355
CONSTRUCTION DOCUMENTS
X
RENDERINGS OPTION 1- FOR REFERENCE ONLY
RENDERINGS - FOR REFERENCE ONLY
1i
1t
ROOM NUMBER
FINISH TYPE
DOOR NUMBER
WALL TYPES
WINDOW NUMBER
EXISTING WALL TO REMAIN
CONCRETE
WOOD BLOCKING
STEEL (LARGE SCALE)
GYPSUM BOARD/PLASTER
RIGID INSULATION
PLYWOOD
ELEMENTS TO BE REMOVED
MATERIAL DESIGNATIONS & SYMBOLS DETAIL / PLAN / ELEVATION
BLDG SECTION CUT
NEW ELEVATION
EXISTING ELEVATION
DRAWING REFERENCE
SHEET REFERENCE
DRAWING REFERENCE
SHEET REFERENCE
CMU
A101
SIM
A101
SIM
WALL SECTION
DRAWING REFERENCE
SHEET REFERENCE
A101
SIM
Room name
BATT INSULATION
EXTENT OF WORK
NEW WALL
MILLWORK
1i
CR
COLUMN CENTER LINE / IDENTIFIER1
REVISION INDICATION
3 HOUR PARTITION
2 HOUR PARTITION
1 HOUR PARTITION
TYPICAL MOUNTING HEIGHTS
1. MOUNTING HEIGHTS SHOWN ARE BASED UPON RECOGNIZED DESIGN
STANDARDS AND/OR BARRIER FREE CODE REQUIREMENTS. IT IS INTENDED
THAT LIKE DEVISES ALL BE MOUNTED AT THE SAME HEIGHT THROUGHOUT THE
ENTIRE PROJECT. RECESSED DEVICES IN MASONRY WALLS MAY DICTATE A
DEVIATION (+/- 2") FROM THESE HEIGHTS (WHEN PERMITTED BY CODE) SO
AS TO ALLOW THE BOTTOM OR THE TOP OF THE DEVICE RECESS TO ALIGN
WITH MASONRY COURSING. COORDINATE THESE DEVIATIONS WITH THE
ARCHITECT'S/OWNER'S REPRESENTATIVE. MOUNTING HEIGHTS ARE TYPICAL
UNLESS NOTED OTHERWISE ON DRAWINGS.
DIMENSIONING
1. DIMENSIONS ARE FROM FINISHED FACE TO FINISHED FACE, UNLESS NOTED
OTHERWISE, SEE DIMENSIONING KEY ON THIS PAGE FOR REFERENCE
GENERAL NOTES
1. THE MOUNTING HEIGHTS, MATERIALS, AND SYMBOLS SHOWN ON THIS PAGE
ARE FOR REFERENCE THROUGHOUT THE PROJECT. NOT ALL ELEMENTS
SHOWN WILL APPLY TO THIS SPECIFIC PROJECT. REVIEW THE PROJECT
PLANS, SECTIONS, AND ELEVATIONS FOR ADDITIONAL DETAILS AND TO
VERIFY WHAT RELATES TO THIS PROJECT.
M
IN
30" MIN
M
IN
52" MIN
FORWARD APPROACH PARALLEL APPROACH
52" MIN
CLEAR FLOOR SPACE
M
IN
ALCOVE, FORWARD APPROACH
X
36" MIN
ALCOVE, SIDE APPROACH
X
60" MIN
REQUIRED CLEARANCES
67" TURNING DIAMETER
60" IN EXISTING
67" MIN. IN NEW CONST
T - SHAPED TURNING SPACE
ALL DIMENSIONS ARE MIN.
1' - 6" 3' - 0" 1' - 6"
8"
M
IN
18" MIN
FRONT APPROACH - PULL SIDE
REQUIRED PUSH/PULL CLEARANCES
M
IN
12" MIN
FRONT APPROACH - PUSH SIDE
M
IN
FRONT APPROACH - PUSH SIDE
M
IN
HINGE APPROACH - PULL SIDE
42" MIN
HINGE APPROACH - PUSH SIDE
M
IN
22" MIN 12" MIN
DIMENSIONING SYSTEM (UNLESS NOTED OTHERWISE)
4"
PARTITION AT
RIGHT ANGLE
2' - 6"FINISH FACE OF
NEW
CONSTRUCTION
COLUMN
LINE
2' - 0"FINISH FACE OF
NEW
CONSTRUCTION
FINISH FACE OF
EXISTING
CONSTRUCTION
ALIGNFINISH FACE OF
NEW
CONSTRUCTION
FINISH FACE OF
EXISTING
CONSTRUCTION
DIMENSIONING KEY
*IF THE DOOR IS
NOT AGAINST A
RIGHT ANGLE
PARTITION OR
EXISTING, IT IS TO BE
CENTERED IN THE
ROOM, U.N.O.
UNOBSTRUCTED
APPROACH
FIRE
EXTINGUISHER
FIRE
EXTINGUISHER
CABINET
HI-LOW ADA
DRINKING
FOUNTAIN
OPTIONAL BOTTLE FILLER,
VERIFY W/OWNER
SHOWER HEAD, VALVES
AND CURTAIN ROD
CURTAIN ROD
SHOWER HEAD
SHOWER
CONTROLS
SANITARY NAPKIN
DISPENSER
M A
X
PAPER TOWEL
DISPENSER
LIQUID SOAP
DISPENSER
COAT HOOK AUTOMATIC
DOOR BUTTON
CLOSET ROD
AND SHELF
HAND LOTION
DISPENSER
UNOBSTRUCTED
APPROACH
OPERATING
PARTS MUST BE
BELOW MAXIMUM
HEIGHT
UNOBSTRUCTED
APPROACH
UNOBSTRUCTED
APPROACH
UNOBSTRUCTED
APPROACH
CLOSET ROD
W/OUT SHELF
UNOBSTRUCTED
APPROACH
FIRE VALVE
CABINET
FIRE HOSE RACK
OR VALVE
MOUNTING HEIGHTS
MAX SLOPE
1' - 0"
1.5" MIN.
2" OD
1.25" TO
HANDRAIL AT TOP OR
BOTTOM OF RAMP
HANDRAIL / GRAB
BAR SIZE AND
WALL SPACING
LINE OF END OR
RAMP AT BOTTOM
(OR TOP)
M
A X
M
IN
RAILING DETAILS
M A
X
BABY
CHANGING
STATION
ADA RESTROOM
SIGN
POST-MOUNTED
PARKING SIGNS
WALL-MOUNTED
PARKING SIGN
M
IN
1' - 0"
M
IN
1' - 0"
RESTROOM M EN'S W OM EN'S
VAN
ACCESSIBLE
M
IN
TO
W O
R K
S U
R
FA
C E
M A
X
MOUNTING HEIGHTS
© 2024 Driven Design Studio, All Rights Reserved.
Driven Design Studio PLLC
117 West Michigan Avenue
Battle Creek, MI 49017
(269) 753-8040 cody@drivendesignstudio.com
PROJECT NUMBER
STAMP
SCALE
DATE
DRAWN BY
PROJECT ADDRESS
PROJECT NAME
ARCHITECTURE/INTERIOR DESIGN
THIS DOCUMENT IS THE EXCLUSIVE
PROPERTY OF DRIVEN DESIGN. THE
DOCUMENT & THE INFORMATION IT
CONTAINS MAY NOT BE REPRODUCED
OR USED FOR OTHER THAN THE
SPECIFIC PROJECT FOR WHICH IT WAS
PREPARED WITHOUT THE EXPLICIT
CONSENT OF DRIVEN DESIGN.
OWNER
ISSUE
10/17/2025 9:32:37 AM
As indicated
T002
GENERAL MOUNTING HEIGHTS +
ABBREVIATIONS
VALENTINE CENTER
75 IRVING PARK DR, BATTLE CREEK, MI
49037
CMN
2025.024
City of Battle Creek
10 N Division St
Battle Creek, MI
(269) 966-3355
CONSTRUCTION DOCUMENTS
X
ABBREVIATION LIST
A/C AIR CONDITIONING
A/V AUDIO/VISUAL
ACP ACOUSTICAL CEILING PANEL
AD AREA DRAIN
ADA AMERICANS WITH DISABILITIES ACT
ADJ ADJUSTABLE
AFF ABOVE FINISHED FLOOR
ALT ALTERNATE
ALUM ALUMINIUM
APPROX APPROXIMATELY
ARCH ARCHITECT(URAL, URE)
ASSOC ASSOCIATED
AUTO AUTOMATIC
AWP ACOUSTICAL WALL PANEL
BD BOARD
BF BARRIER FREE
BIT BITUMINOUS, BITUMEN
BLDG BUILDING
BLKG BLOCKING
BM BEAM
BOT BOTTOM
CAB CABINET
CJ CONTROL JOINT
CLG CEILING
CLR CLEAR(ANCE)
CMU CONCRETE MASONRY UNIT
COL COLUMN
COM COMMUNICATIONS
CONC CONCRETE
CONFIG CONFIGURATION
CONST CONSTRUCTION
CONT CONTINUOUS
COORD COORDINATE
CORR CORRIDOR
CPT CARPET
CT CERAMIC TILE
CTR CENTER
DEG DEGREE
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DIV DIVISION
DN DOWN
DR DOOR
DS DOWNSPOUT
DTL DETAIL
DWG(S) DRAWING(S)
E EAST
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATION
EMER EMERGENCY
ENCL ENCLOS(E,URE)
EQ EQUAL
EQUIP EQUIPMENT
EST ESTIMATE(D)
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
FA FIRE ALARM
FD FLOOR DRAIN
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISHED FACE
FGL FIBERGLASS
FHC FIRE HOSE CABINET
FIXT FIXTURE
FL FLOOR(ING)
FLUOR FLUORESCENT
FOC FACE OF CONCRETE
FOS FACE OF STUDS
FP FIREPROOF(ING)
FT FEET
FTG FOOTING
FUR FURR(ED,ING)
GA GAUGE
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACT(OR)
GL GLASS, GLAZING
GOVT GOVERNMENT
GT GROUT
GYP BD GYPSUM WALLBOARD
HC HOLLOW CORE
HDR HEADER
HDWD HARDWOOD
HDWR HARDWARE
HGT HEIGHT
HM HOLLOW METAL
HORIZ HORIZONTAL
HP HIGH POINT
HR HOUR
HT HEIGHT
HVAC HEATING, VENTILATION & AIR
CONDITIONING
ABBREVIATION LIST
ID INSIDE DIAMETER
IN INCH(ES)
INCAN INCANDESCENT
INCL INCLUDE(D,ING)
INSUL INSULATION, INSULATED
INT INTERIOR
JAN JANITOR
JT(S) JOINT(S)
KIT KITCHEN
LAM LAMINATE(D)
LAV LAVATORY
LBL LABEL
LH LEFT HAND
LL LIVE LOAD
LP LOW POINT
LTG LIGHTING
LTL LINTEL
MANF MANUFACTURE(R)
MAS MASONRY
MATL MATERIAL(S)
MAX MAXIMUM
MECH MECHANICAL
MEMB MEMBRANE
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MTD MOUNTED
MTG MOUNTING
MTL METAL
N NORTH
N/A NOT APPLICABLE
NAT NATURAL
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OH OVERHEAD
OPNG OPENING
OPP OPPOSITE
OPP HD OPPOSITE HAND
PART PARTITION
PC PRECAST
PERF PERFORATE(D)
PL PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLWD PLYWOOD
PNL PANEL(ED)
PR PAIR
PREP PREPARE (SURFACE)
PROV PROVIDE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT
PVMT PAVEMENT
QTY QUANTITY
R RISER
RAD RADIUS
RB RUBBER BASE
REF REFRIDGERATOR
REINF REINFORCED
REQD /
REQ'D
REQUIRED
RES RESILIENT
RET RETAINING
REV REVISION(S) / REVISE(D)
RFG ROOFING
RH RIGHT HAND
RM ROOM
RO ROUGH OPENING
S SOUTH
SC SOLID CORE
SCHED SCHEDULE
SECT SECTION
SF SQUARE FEET
SHT SHEET
SIM SIMILAR
SPEC(S) SPECIFICATION(S)
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STL STEEL
STN STAIN
STO STORAGE
STRUC STRUCTURAL
SUSP SUSPENDED
SYM SYMMETRICAL
SYS SYSTEM
T TREAD
T&G TONGUE AND GROOVE
T.O. TOP OF
TECH TECHNOLOGY
TEL TELEPHONE
TEMP TEMPERED
THK THICK(NESS)
ABBREVIATION LIST
THRESH THRESHOLD
TOC TOP OF CURB
TOM TOP OF MASONRY
TOS TOP OF STEEL
TOW TOP OF WALL
TRANS TRANSPARENT
TV TELEVISION
TYP TYPICAL
UL UNDERWRITER'S LABORATORY
UNFIN UNFINISHED
UNO UNLESS OTHERWISE NOTED
VAR VARIES
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
VU VENTILATION UNIT
VWC VINYL WALLCOVERING
W WATER RESISTANT
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WOOD
WDW WINDOW
WH WALL HUNG
WP WORK POINT
WR PAINT(ED)
WT WEIGHT
WWF WELDED WIRE FABRIC
# NUMBER
& AND
+/- EXIST (OR APPROX) DIM - VIF
CL CENTER LINE
L ANGLE
M
IN
C
LE
A
R
7' 4" - MIN. CLEAR
32" CLEAR MIN.
ADA RESTROOM PLAN - NTS
30" X 52" LAVATORY
CLEAR FLOOR SPACE
IN NEW CONST. (30" X
48" IN EXISTING BLDGS.)
30" X 52" MANEUVERING
CLEAR FLOOR SPACE PAST
DOOR SWING
67" DIAMETER TURNING
SPACE FOR NEW
CONST. (60" DIA. FOR
EXISTING BLDGS)
54" x 60" CLEAR FLOOR
SPACE AT DOOR
60" X 59" WATER
CLOSET CLEAR FLOOR
SPACE (SHADED)
1' - 6"1' - 6" TYP
M
IN
11" MIN.
8" MIN.
LAVATORY
LAVATORY
WIDTH
MIN. ROOM
WIDTH
20" 6'-11"
21" 7'-0"
22" 7'-1"
LAVATORY NOT
CENTERED ON
30 X 48 CLEAR AREA
M
IN
M
A X
M
IN
MAX.
3"
1' - 6"
6" 3' - 0"
REQUIRED CLEAR SPACE
1'-0" ABOVE AND 1 1/2"
BELOW GRAB BAR
9"
42" MIN.
MAX.
1' - 0"
M
IN
EDGE OF REFLECTIVE
SURFACE
INSTALL TRUEBRO LAV
GUARD 2 UNDERSINK
PIPING COVER OR EQ. AT
ALL UNDERSINK PIPING
TOILET PAPER DISPENSER
SANITARY NAPKIN DISPOSAL
MIN. CLEAR
3' - 0" *
* CAN BE 2'-6" IF PARTITION SCREEN
DOES NOT EXTEND PAST URINAL
WALL MTD. SCREEN REQUIRED ON
EACH SIDE OF URINAL
URINALADA RESTROOM SIDE VIEWADA RESTROOM FRONT VIEW
ELEC OUTLETS NEAR SINKS IN
BF TOILET ROOMS TO BE
MOUNTED 33" TO 36" AFF TO
CENTERLINE AND BE GFI
MIN.
1' - 3"
MIN
2' - 6"
RESTROOM DETAILS - NTS
*NOTE: PROVIDE BLOCKING AS
REQUIRED FOR ALL GRAB BARS AND
FIXTURE MOUNTING PER
MANUFACTURER'S RECOMMENDATION
39"-41"
S
TA
N D
A R
D
B .F
M
A X
M A
X
5' - 0" MIN. 2' - 0"
M
A X
B .F
M
A X1
M
A X
67" DIA. FOR NEW CONST.
60" DIA. FOR EXISTING BLDGS.
7'-4 " M
IN
.7' 4" MIN.
18" O .C
30" M
IN
M
A X
M A
X
36" G
RAB BAR
30"X36"
MIRROR
PAPER
DISPENSER
" M A
X
42" GRAB
BAR
18" GRAB BAR
TOILET
COVER
DISPENSER
TOILET PAPER
DISPENSER
CLEAR FLOOR SPACE
30" X 52" (NEW
30" X 48" (EXIST.)
REST
ROOM
ENTR
Y
TILE ON WET WALL GYP. BD. OR TILE, SEE
FINISH SCHEDULE
ADA RESTROOM AXON - NTS
1.5" MIN.
2" OD
1.25" TO
HANDRAIL / GRAB
BAR SIZE AND
WALL SPACING
MEDICINE
CABINET
MEDICINE
CABINET
(BF)
M A
X
TO
U
S A
B
LE
S H
E
LF
TOWEL
BAR AND
SHELF
TOWEL
BAR
M
A X
MIRROR /
VANITY
COUNTER
M
IN
M A
X
M
IN
1' - 6" MIN.
DRESSING
MIRROR
(BF)
SEAT
COVER
DISP
(B F)
TOWEL DISP
OR MULTI-
PURPOSE
UNIT
TOWEL DISP
AND WASTE
RECEPTACLE
HEIGHT OF DISPENSER
OR OPERATING
CONTROLS
M
IN
WASTE
RECEPT
B
F
FACIAL
TISSUE
DISP
SANITARY
NAPKIN DISP
SOAP
DISH
HAND
DRYER
SOAP
DISP
TOILET PAPER
HOLDER
BASE CABINET WITH
SINK & KNEE SPACE
(BF)
LINE OF WALL
2' - 0"
4"
TO
R
IM
M
A X
(2
B F)
(3
B F)
BACKSPLASH
M
IN
M A
X
TO
6" MAX.
MIN.
8"
17" TO 19"
3" MAX.
WALL AND BASE
CABINETS
HIGH-LOW EWC OR
DRINKING FOUNTAIN
M A
X
M
A X
M
A X
ADDITIONAL RESTROOM MOUNTING HEIGHTS
© 2024 Driven Design Studio, All Rights Reserved.
Driven Design Studio PLLC
117 West Michigan Avenue
Battle Creek, MI 49017
(269) 753-8040 cody@drivendesignstudio.com
PROJECT NUMBER
STAMP
SCALE
DATE
DRAWN BY
PROJECT ADDRESS
PROJECT NAME
ARCHITECTURE/INTERIOR DESIGN
THIS DOCUMENT IS THE EXCLUSIVE
PROPERTY OF DRIVEN DESIGN. THE
DOCUMENT & THE INFORMATION IT
CONTAINS MAY NOT BE REPRODUCED
OR USED FOR OTHER THAN THE
SPECIFIC PROJECT FOR WHICH IT WAS
PREPARED WITHOUT THE EXPLICIT
CONSENT OF DRIVEN DESIGN.
OWNER
ISSUE
10/17/2025 9:32:38 AM
As indicated
T003
PLUMBING MOUNTING HEIGHTS
VALENTINE CENTER
75 IRVING PARK DR, BATTLE CREEK, MI
49037
CMN
2025.024
City of Battle Creek
10 N Division St
Battle Creek, MI
(269) 966-3355
CONSTRUCTION DOCUMENTS
X
117 West Michigan Avenue
Battle Creek, MI 49017
(269) 753-8040 cody@drivendesignstudio.com
PROJECT NUMBER
STAMP
SCALE
DATE
DRAWN BY
PROJECT ADDRESS
PROJECT NAME
ARCHITECTURE/INTERIOR DESIGN
THIS DOCUMENT IS THE EXCLUSIVE
PROPERTY OF DRIVEN DESIGN. THE
DOCUMENT & THE INFORMATION IT
CONTAINS MAY NOT BE REPRODUCED
OR USED FOR OTHER THAN THE
SPECIFIC PROJECT FOR WHICH IT WAS
PREPARED WITHOUT THE EXPLICIT
CONSENT OF DRIVEN DESIGN.
OWNER
ISSUE
10/17/2025 9:32:38 AM
T004
CODE COMPLIANCE - REHAB CODE
VALENTINE CENTER
75 IRVING PARK DR, BATTLE CREEK, MI
49037
CMN
2025.024
City of Battle Creek
10 N Division St
Battle Creek, MI
(269) 966-3355
CONSTRUCTION DOCUMENTS
X
2021 MICHIGAN REHABILITATION CODE
CHAPTER 6: CLASSIFICATION OF WORK
SECTION 604
AREA OF RENOVATION = 7,107 SQUARE FEET, WHICH IS 93% OF THE TOTAL BUILDING AREA.
THE WORK IS GREATER THAN 50% AND THEREFORE IS CONSIDERED A LEVEL 3 ALTERATION.
SECTION 508.2 EXCEPT AS SPECIFICALLY PROVIDED FOR IN CHAPTER 12, HISTORIC BUILDINGS SHALL COMPLY WITH APPLICABLE PROVISIONS OF THIS CODE FOR THE TYPE OF WORK BEING PERFORMED. THE BUILDING IS CURRENTLY LISTED ON THE STATE REGISTRY OF HISTORIC PROPERTIES.
CHAPTER 7: ALTERATIONS - LEVEL 1
SECTION 702.5 EMERGENCY ESCAPE AND RESCUE OPENINGS. WHERE WINDOWS ARE REQUIRED TO PROVIDE EMERGENCY ESCAPE AND RESCUE OPENINGS IN GROUP R-2 AND R-23 OCCUPANCIES AND ONE AND TWO FAMILY DWELLINGS AND TOWNHOUSES REGULATED BY THE INTERNATIONAL RESIDENTIAL CODE, REPLACEMENT WINDOWS SHALL BE EXEMPT FROM THE REQUIREMENTS OF SECTIONS 1030.2, 1030.3 AND 1030.5 OF THE INTERNATIONAL BUILDING CODE AND SECTIONS R310.21
AND R310.2.3 OF THE INTERNATIONAL RESIDENTIAL CODE ACCORDINGLY. PROVIDED THE REPLACEMENT WINDOW IS THE MANUFACTURER'S LARGEST STANDARD SIZE WINDOW THAT WILL FIT WITHIN THE EXISTING FRAME OR EXISTING ROUGH OPENING. THE REPLACEMENT WINDOW SHALL BE PERMITTED TO BE OF THE SAME OPERATING STYLE AS THE EXISTING WINDOW OR A STYLE THAT PROVIDES FOR AN EQUAL OR GREATER WINDOW OPENING AREA THAN THE EXISTING WINDOWS.
SECTION 702.6 MATERIALS AND METHODS. ALL NEW WORK SHALL COMPLY WITH THE MATERIALS AND METHOD REQUIREMENTS IN THE INTERNATIONAL BUILDING CODE, INTERNATIONAL ENERGY CONSERVATION CODE, INTERNATIONAL MECHANICAL CODE, AND INTERNATIONAL PLUMBING CODE, AS APPLICABLE, THAT SPECIFY MATERIAL STANDARDS, DETAIL OF INSTALLATION AND CONNECTION, JOINTS, PENETRATIONS, AND CONTINUITY OF ANY ELEMENT, COMPONENT, OR SYSTEM IN THE
BUILDING.
SECTION 704.1 GENERAL. ALTERATIONS SHOWS BE DONE IN A MANNER THAT MAINTAINS THE LEVEL OF PROTECTION PROVIDED FOR THE MEANS OF EGRESS.
SECTION 708.1 MINIMUM REQUIREMENTS. LEVEL 1 ALTERATIONS TO EXISTING BUILDINGS OR STRUCTURES ARE PERMITTED WITHOUT REQUIRING THE ENTIRE BUILDING OR STRUCTURE TO COMPLY WITH THE ENERGY REQUIREMENTS OF THE INTERNATIONAL ENERGY CONSERVATION CODE OR INTERNATIONAL RESIDENTIAL CODE. THE ALTERATIONS SHALL CONFIRM TO THE ENERGY REQUIREMENTS OF THE INTERNATIONAL ENERGY CONSERVATION CODE OR INTERNATIONAL RESIDENTIAL CODE AS
THEY RELATE TO NEW CONSTRUCTION ONLY.
CHAPTER 8: ALTERATIONS - LEVEL 2
SECTION 801.3 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE. EXCEPTIONS: 1. WINDOWS MAY BE ADDED WITHOUT REQUIRING COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE. 2. NEWLY INSTALLED ELECTRICAL EQUIPMENT SHALL COMPLY WITH THE REQUIREMENTS OF SECTION 808. 3. THE
LENGTH OF DEAD-END CORRIDORS IN NEWLY CONSTRUCTED SPACES SHALL ONLY BE REQUIRED TO COMPLY WITH THE PROVISIONS OF SECTION 805.6. 4. THE MINIMUM CEILING HEIGHT OF THE NEWLY CREATED HABITABLE AND OCCUPIABLE SPACES AND CORRIDORS SHALL BE 7 FEET.
SECTION 803.2 VERTICAL OPENINGS. EXISTING VERTICAL OPENINGS SHALL COMPLY WITH THE PROVISIONS OF SECTION 803.1, 803.2.2, AND 803.2.3.
SECTION 803.2.1 EXISTING VERTICAL OPENINGS. ALL EXISTING INTERIOR VERTICAL OPENINGS CONNECTING TWO OR MORE FLOORS SHALL BE ENCLOSED WITH APPROVED ASSEMBLIES HAVING A FIRE-RESISTANCE RATING OF NOT LESS THAN 1 HOUR WITH APPROVED OPENING PROTECTIVE. EXCEPTIONS: 1.WHERE VERTICAL OPENING ENCLOSURE IS NOT REQUIRED BY THE INTERNATIONAL BUILDING OR INTERNATIONAL FIRE CODE. 2. INTERIOR VERTICAL OPENINGS OTHER THAN STAIRWELLS MAY
BE BLOCKED AT THE FLOOR AND CEILING OF THE WORK AREA BY INSTALLATION OF NEW LESS THAN 2" OF SOLID WOOD OR EQUIVALENT CONSTRUCTION. 3. THE ENCLOSURE SHALL NOT BE REQUIRED WHERE: 3.1 CONNECTING THE MAIN FLOOR AND MEZZANINES, OR 3.2 ALL OF THE FOLLOWING REQUIREMENTS ARE MET: THE COMMUNICATING AREA HAS A LOW HAZARD OCCUPANCY OR HAS A MODERATE HAZARD OCCUPANCY THAT IS PROTECTED THROUGHOUT WITH AN AUTOMATIC
SPRINKLER SYSTEM. 3.2.2 THE LOWEST OR NEXT TO THE LOWEST LEVEL IS THE STREET LEVEL. 3.2.3 THE ENTIRE AREA IS OPEN AND UNOBSTRUCTED IN A MANNER SUCH THAT IT MAY NE ASSUMED THAT A FIRE IN ANY PART OF THE INTERCONNECTED SPACES WILL BE READILY OBVIOUS TO ALL OF THE OCCUPANTS. 3.2.4 EXIT CAPACITY IS SUFFICIENT TO PROVIDE EGRESS SIMULTANEOUSLY FOR ALL OCCUPANTS OF ALL LEVELS BY CONSIDERING ALL AREAS TO BE A SINGLE FLOOR AREA FOR THE
DETERMINATE OF REQUIRED EXIT CAPACITY. 3.2.5 EACH FLOOR LEVEL, CONSIDERED SEPARATELY HAS AT LEAST ONE-HALF OF ITS INDIVIDUAL REQUIRED EXIT CAPACITY PROVIDE BY AN EXIT OR EXITS LEADING DIRECTLY OUT OF THAT LEVEL WITHOUT HAVING TO TRAVERSE ANOTHER COMMUNICATING FLOOR LEVEL OR BE EXPOSED TO THE SMOKE OR FIRE SPREADING FROM ANOTHER COMMUNICATING FLOOR LEVEL.
SECTION 803.2.1 #11. IN GROUP R-2 OCCUPANCIES, A MINIMUM 30-MINUTE ENCLOSURE SHALL BE PROVIDED TO PROTECT ALL VERTICAL OPENINGS NOT EXCEEDING THREE STORIES. THIS ENCLOSURE OF THE ENCLOSURE SPECIFIED IN SECTION 803.2.1, SHALL NOT BE REQUIRED IN THE FOLLOWING LOCATIONS: 11.1 VERTICAL OPENINGS NOT EXCEEDING TWO STORIES WITH NOT MORE THAN FOUR DWELLING UNITS PER FLOOR. 11.2 BUILDINGS PROTECT THROUGHOUT BY AN APPROVED
AUTOMATIC SPRINKLER SYSTEM. 11.3 BUILDING WITH NOT MORE THAN FOUR DWELLING UNITS PER FLOOR WHERE EVERY SLEEPING ROOM ABOVE THE SECOND FLOOR IS PROVIDED WITH DIRECT ACCESS TO A FIRE ESCAPE OR OTHER APPROVED EXTERIOR DOOR OR WINDOW S HAVING A SILL HEIGHT OR NOT GREAT THAN 44 INCHES AND THE BUILDING IS PROTECTED THROUGHOUT BY AN AUTOMATIC FIRE ALARM SYSTEM COMPLYING WITH SECTION 804.4.
SECTION 804.2.2.1 MIXED USES. IN WORK AREAS CONTAINING MIXED USES, ONE OR MORE OF WHICH REQUIRES AUTOMATIC SPRINKLER PROTECTION IN ACCORDANCE WITH SECTION 804.2.2, WHICH PROTECTION SHALL NOT BE REQUIRED THROUGHOUT THE WORK AREA PROVIDED THAT THE USES REQUIRING SUCH PROTECTION ARE SEPARATED FROM THOSE NOT REQUIRING PROTECTION BY FIRE RESISTANCE RATED CONSTRUCTION HAVING A MINIMUM 2-HOUR RATING FOR GROUP H AND A
MINIMUM 1-HOUR RATING FOR ALL OTHER OCCUPANCY GROUPS.
SECTION 804.4.1.6 A FIRE ALARM SYSTEM SHALL BE INSTALLED IN WORK AREAS OF GROUP R-2 APARTMENT BUILDINGS AS REQUIRED BY THE INTERNATIONAL FIRE CODE FOR EXISTING GROUP R-2 OCCUPANCIES.
SECTION 804.4.3 INDIVIDUAL SLEEPING UNITS AND INDIVIDUAL DWELLING UNITS IN ANY WORK AREA IN GROUP R OCCUPANCIES SHALL BE PROVIDED WITH SMOKE ALARMS IN ACCORDANCE WITH THE MICHIGAN BUILDING CODE.
SECTION 805.3.1 EVERY STORY UTILIZED FOR HUMAN OCCUPANCY ON WHICH THERE IS A WORK AREA THAT INCLUDES EXIT OR CORRIDORS SHARED BY MORE THAN ONE TENANT WITHIN THE WORK AREA SHALL BE PROVIDED WITH THE MINIMUM NUMBER OF EXITS BASED ON THE OCCUPANCY AND THE OCCUPANT LOAD IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE.
SECTION 805.3.1.1 SINGLE-EXIT BUILDINGS. ONLY ONE EXIT IS REQUIRED FROM BUILDINGS AND SPACES OF THE FOLLOWING OCCUPANCIES. 5. GROUPS R-1 AND R-2 NOT MORE THAN TWO STORIES IN HEIGHT, WHEN THERE ARE NOT MORE THAN FOUR DWELLING UNITS PER FLOOR AND THE EXIT ACCESS TRAVEL DISTANCE DOES NOT EXCEED 50 FEET. THE MINIMUM FIRE-RESISTANCE RATING OF THE EXIT ENCLOSURE AND OF THE OPENING PROTECTION SHALL BE 1 HOUR. 6. IN MULTILEVEL DWELLING
UNITS IN BUILDINGS OF
SECTION 805.4.3 IN ANY WORK AREA, ALL DOORS OPENING ONTO AN EXIT PASSAGEWAY AT GRADE OR AN EXIT STAIRWAY SHALL BE SELF-CLOSING OR AUTOMATIC-CLOSING BY LISTED CLOSING DEVICES.
SECTION 805.5.1 ALL DWELLING UNIT OR SLEEPING UNIT CORRIDOR DOORS IN WORK AREAS IN BUILDINGS OF GROUPS R-2 SHALL BE AT LEAST 1 3/8" SOLID CORE WOOD OR APPROVED EQUIVALENT AND SHALL BE EQUIPPED WITH APPROVED DOOR CLOSERS. EXCEPTION 5: DOOR ASSEMBLIES HAVING A FIRE PROTECTION RATING OF AT LEAST 20 MINUTES.
SECTION 805.5.2 TRANSOMS. IN ALL BUILDINGS OF GROUP I-1, I-2, R-1, AND R-2 OCCUPANCIES, ALL TRANSOMS IN CORRIDOR WALLS IN WORK AREAS SHALL BE EITHER GLAZED WITH 1/4" WIRED GLASS SET IN METAL FRAMES OR OTHER GLAZING ASSEMBLIES HAVING A FIRE PROTECTION RATING AS REQUIRED FOR THE DOOR AND PERMANENTLY SECURED IN THE CLOSED POSITION OR SEALED WITH MATERIAL CONSISTENT WITH THE CORRIDOR CONSTRUCTION.
SECTION 805.6 DEAD-END CORRIDORS IN ANY WORK AREA SHALL NOT EXCEED 35 FEET.
SECTION 805.8.1 MEANS OF EGRESS IN ALL WORK AREAS SHALL BE PROVIDED WITH EXIT SIGNS IN ACCORDANCE WITH THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE.
SECTION 807.2 NEW STRUCTURAL ELEMENTS IN ALTERATIONS SHALL COMPLY WITH THE INTERNATIONAL BUILDING CODE.
SECTION 807.4 ALTERATIONS SHALL NOT REDUCE THE CAPACITY OF EXISTING GRAVITY LOAD-CARRYING STRUCTURAL ELEMENTS UNLESS IT IS DEMONSTRATED THAT THE ELEMENTS HAVE THE CAPACITY TO CARRY THE APPLICABLE DESIGN GRAVITY LOADS REQUIRED BY THE INTERNATIONAL BUILDING CODE.
SECTION 808.1 ALL NEWLY INSTALLED ELECTRICAL EQUIPMENT AND WIRING RELATING TO WORK DONE IN ANY WORK AREA SHALL COMPLY WITH ALL APPLICABLE REQUIREMENTS OF NFPA 70.
SECTION 809.1 ALL RECONFIGURED SPACES INTENDED FOR OCCUPANCY AND ALL SPACES CONVERTED TO HABITABLE SPACE IN ANY WORK AREA SHALL BE PROVIDED WITH NATURAL OR MECHANICAL VENTILATION IN ACCORDANCE WITH THE INTERNATIONAL MECHANICAL CODE.
SECTION 811.1 LEVEL 2 ALTERATIONS TO EXISTING BUILDINGS SHALL CONFORM TO THE ENERGY REQUIREMENTS OF THE INTERNATIONAL ENERGY CONSERVATION CODE AS THEY RELATE TO NEW CONSTRUCTION ONLY.
CHAPTER 9: ALTERATIONS - LEVEL 3
SECTION 901.1 SCOPE. LEVEL 3 ALTERATIONS AS DESCRIBED IN SECTION 505 SHALL COMPLY WITH THE REQUIREMENTS OF THIS CHAPTER.
SECTION 903.1 EXISTING SHAFTS AND VERTICAL OPENINGS. EXISTING STAIRWAYS THAT ARE PART OF THE MEANS OF EGRESS SHALL BE ENCLOSED IN ACCORDANCE WITH SECTION 803.2.1 FROM THE HIGHEST WORK AREA FLOOR TO, AND INCLUDING, THE LEVEL OF EXIT DISCHARGE AND ALL FLOORS BELOW.
SECTION 903.3 INTERIOR FINISH. INTERIOR FINISH IN EXITS SERVING THE WORK AREA SHALL COMPLY WITH SECTION 803.4 BETWEEN THE HIGHEST FLOOR ON WHICH THERE IS A WORK AREA TO THE FLOOR OF EXIT DISCHARGE.
SECTION 904.1 AUTOMATIC SPRINKLER SYSTEMS. AN AUTOMATIC SPRINKLER SYSTEM SHALL BE REQUIRED BY SECTION 804.2 OR THIS SECTION.
SECTION 904.2 FIRE ALARM AND DETECTION SYSTEMS. FIRE ALARM AND DETECTION SHALL BE PROVIDED IN ACCORDANCE WITH SECTION 907 OF THE INTERNATIONAL BUILDING CODE AS REQUIRED FOR NEW CONSTRUCTION.
SECTION 906.2 TYPE B DWELLING OR SLEEPING UNITS. WHERE FOUR OR MORE GROUP I-1, I-2, R-1, R-2, R-3, OR R-4 DWELLING OR SLEEPING UNITS ARE BEING ALTERED, THE REQUIREMENTS OF SECTION 1107 OF THE INTERNATIONAL BUILDING CODE FOR TYPE B UNITS AND CHAPTER 9 OF THE INTERNATIONAL BUILDING CODE FOR VISIBLE ALARMS APPLY ONLY TO THE QUANTITY OF THE SPACES BEING ALTERED. EXCEPTION: GROUP I-1, I-2, R-2, R-3, AND R-4 DWELLING OR SLEEPING UNITS WHERE THE
FIRST CERTIFICATE OF OCCUPANCY WAS ISSUED BEFORE MARCH 15TH, 1991 ARE NOT REQUIRED TO PROVIDE TYPE B DWELLING OR SLEEPING UNITS.
SECTION 908.1 MINIMUM REQUIREMENTS. LEVEL 3 ALTERATIONS TO EXISTING BUILDINGS OR STRUCTURES ARE PERMITTED WITHOUT REQUIRING THE ENTIRE BUILDING OR STRUCTURE TO COMPLY WITH THE ENERGY REQUIREMENTS OF THE INTERNATIONAL ENERGY CONSERVATION CODE OR INTERNATIONAL RESIDENTIAL CODE. THE ALTERATIONS SHALL CONFIRM TO THE ENERGY REQUIREMENTS OF THE INTERNATIONAL ENERGY CONSERVATION CODE OR INTERNATIONAL RESIDENTIAL CODE AS
THEY RELATE TO NEW CONSTRUCTION ONLY.
FE
SYMBOL ITEM
FIRE EXTINGUISHER
EXIT SIGN W/ EGRESS LIGHTS
EGRESS LIGHTING
TRAVEL DISTANCE
1 HOUR WALL
2 HOUR WALL
COMPLIANCE LEGEND
EDUCATION
INSTITUTIONAL
NOT IN SCOPE
EGRESS TRAVEL
DISTANCE = 25'
EGRESS TRAVEL
DISTANCE = 21'
EGRESS TRAVEL
DISTANCE = 36'
EGRESS TRAVEL
DISTANCE = 25'
EGRESS TRAVEL
DISTANCE = 33'
EGRESS TRAVEL
DISTANCE = 39'
EGRESS TRAVEL
DISTANCE = 36'
3235 SF
EDUCATIONAL
658 SF
EDUCATIONAL
770 SF
EDUCATIONAL
Not
Enclosed
INSTITUTIONAL I-4
99 SF
INSTITUTIONAL I-4
212 SF
INSTITUTIONAL I-4
88 SF
STORAGE
253 SF
NOT IN SCOPE
217 SF
NOT IN SCOPE
CHILDREN AGES 2-4
PLANNED OCCUPANCY = 93
CHILDREN AGES 2-4
PLANNED OCCUPANCY = 22
INFANTS ROOM
PLANNED OCCUPANCY = 19
1. ENSURE EXIT SIGNS ARE MOUNTED ABOVE THE DOORS AND VISIBLE FROM 75 FEET AWAY. ALL EGRESS LIGHTING IS TO POINT
DOWN TO ILLUMINATE THE EGRESS PATH OF TRAVEL.
2. ALL FIRE EXTINGUISHERS ARE TO BE ABC EXTINGUISHERS, UNLESS NOTED OTHERWISE. ALL EXTINGUISHERS ARE TO BE TAGGED
WITH THE CURRENT YEAR'S INSPECTION ON IT. ANNUAL INSPECTIONS ARE TO OCCUR FOR ALL FIRE EXTINGUISHERS.
3. PROVIDE ADA RESTROOM SIGNS AT ALL RESTROOMS, CORRESPONDING TO THE CORRECT SEX.
4. SEE T002 FOR MOUNTING HEIGHTS AND LOCATIONS
5. SEE T003 FOR ADDITIONAL CODE COMPLIANCE INFORMATION
6. FURNITURE AND EQUIPMENT SHOWN ON COMPLIANCE DRAWINGS ARE FOR REFERENCE ONLY
CHAPTER 7: FIRE AND SMOKE PROTECTION
SECTION 708.3 EXCEPTION 1: CORRIDOR WALLS PERMITTED TO HAVE A 1/2 HOUR FIRE RESISTANCE RATING BY TABLE 1020.1.
TABLE 716.5 OPENINGS IN ONE HOUR FIRE BARRIERS FOR SHAFTS, EXIT ACCESS STAIRWAYS, AND INTERIOR EXIT STAIRWAYS ARE
TO HAVE ONE HOUR FIRE DOORS
CHAPTER 12: INTERIOR ENVIRONMENT
SECTION 1208.2 OCCUPIABLE SPACES, HABITABLE SPACES, AND CORRIDORS SHALL HAVE A CEILING HEIGHT OF NOT LESS THAN
7'-6". BATHROOMS, TOILET ROOMS, KITCHENS, STORAGE ROOMS, AND LAUNDRY ROOMS SHALL HAVE A CEILING HEIGHT OF
NOT LESS THAN 7'-0".
EXCEPTION 4: CORRIDORS CONTAINED WITHIN A DWELLING UNIT OR SLEEPING UNIT IN A GROUP R OCCUPANCY SHALL HAVE
A CEILING HEIGHT OF NOT LESS THAN 7'-0".
CODE COMPLIANCE GENERAL NOTES
© 2024 Driven Design Studio, All Rights Reserved.
Driven Design Studio PLLC
117 West Michigan Avenue
Battle Creek, MI 49017
(269) 753-8040 cody@drivendesignstudio.com
PROJECT NUMBER
STAMP
SCALE
DATE
DRAWN BY
PROJECT ADDRESS
PROJECT NAME
ARCHITECTURE/INTERIOR DESIGN
THIS DOCUMENT IS THE EXCLUSIVE
PROPERTY OF DRIVEN DESIGN. THE
DOCUMENT & THE INFORMATION IT
CONTAINS MAY NOT BE REPRODUCED
OR USED FOR OTHER THAN THE
SPECIFIC PROJECT FOR WHICH IT WAS
PREPARED WITHOUT THE EXPLICIT
CONSENT OF DRIVEN DESIGN.
OWNER
ISSUE
10/17/2025 9:32:40 AM
As indicated
T005
CODE COMPLIANCE
VALENTINE CENTER
75 IRVING PARK DR, BATTLE CREEK, MI
49037
CMN
2025.024
City of Battle Creek
10 N Division St
Battle Creek, MI
(269) 966-3355
CONSTRUCTION DOCUMENTS
X
CODE COMPLIANCE
TOPIC SECTION ALLOWED/REQUIRED ACTUAL
APPLICABLE CODES
2021 MICHIGAN BUILDING CODE
2021 MICHIGAN MECHANICAL
CODE
2021 MICHIGAN PLUMBING CODE
2021 MICHIGAN REHABILITATION
CODE
604 LEVEL III ALTERATION WORK AREA EXCEEDS 50% OF TOTAL BUILDING AREA
2021INTERNATIONAL FIRE CODE
2023 MICHIGAN ELECTRICAL CODE
ANSI/ASHRAE 90.1-2019
ICC/ANSI 117.1-2017
NFPA 101 (2021) / NFPA 13 (2019)
ZONING
ZONING CITY OF
BATTLE
CREEK
GRN - GREEN
1 - SCOPE AND ADMIN
DEFERRED SUBMITTALS 107.3.4.1 THERE ARE NO DEFERRED SUBMITTALS FOR THIS
PROJECT
DESIGN PROFESSIONAL IN CHARGE 107.3.4 CODY NEWMAN IS TO BE THE DESIGN PROFESSIONAL
IN CHARGE
SPECIAL INSPECTIONS 110 THERE ARE NO SPECIAL INSPECTIONS FOR THIS
PROJECT
5 - GENERAL BUILDING HEIGHTS AND AREAS
ALLOWABLE BUILDING HEIGHT TABLE
504.3
65 FEET 20 FEET AT MAX.
BASE STORIES ALLOWED TABLE
504.4
3 STORIES 1 STORY
TABULAR AREA TABLE
506.2
23,500 SF 7,576 SF
6 - TYPE OF CONSTRUCTION
TYPE OF CONSTRUCTION TABLE
III-A
7 - FIRE AND SMOKE PROTECTION
SMOKE AND CARBON MONOXIDE DETECTORS
REQUIRED THROUGHOUT
9 - FIRE PROTECTION SYSTEMS
AUTOMATIC SPRINKLER SYSTEM 903.2.1.3 LESS THAN 12,000 SF, NOT REQUIRED 7,149 SF, NOT REQUIRED
FIRE ALARM AND DETECTION
SYSTEMS
907 MANUAL FIRE ALARM REQUIRED AT MIN. PROVIDED
27 - ELECTRICAL
EMERGENCY LIGHTING 1008.1 WILL COMPLY ON COMPLIANCE DRAWINGS
EMERGENCY POWER 1008.3.2,
1008.3.3
WILL COMPLY ON COMPLIANCE DRAWINGS
EXIT SIGNS 1011.1 WILL COMPLY ON COMPLIANCE DRAWINGS
28 - PLUMBING
TABLE 403.1
PLUMBING
CLASS OCCUPANCY
WATER CLOSETS LAVATORIES DRINKING FOUNTAINS
REQUIRED PROVIDED REQUIRED PROVIDED REQUIRED PROVIDED
I-4 190 7 MALE / 7 FEMALE SEE BELOW 7 MALE / 7 FEMALE SEE ELOW 2 REQUIRED SEE BELOW
10 - OCCUPANCY
OCCUPANCY TYPE AREA OCCUPANCY
INSTITUTIONAL
DAY CARE 5062 SF 147
NOT IN SCOPE
DAY CARE 469 SF 15
5531 SF 162
10 - MEANS OF EGRESS
TOTAL
OCCUPANCY
DOOR EGRESS WIDTH 1005.3.2
EXIT ACCESS TRAVEL DISTANCE
TABLE 1017.2
NUMBER OF EXITS TABLE
1006.3.1 STAIR EGRESS WIDTH 1005.3.1
REQUIRED PROVIDED ALLOWED PROVIDED REQUIRED PROVIDED REQUIRED PROVIDED
190 38" 38" 200 FEET 50 2 EXITS 6 EXITS 57" N/A
1/8" = 1'-0"T005
1 FIRST FLOOR COMPLIANCE PLAN
3 - BUILDING AREA BY USE
OCCUPANCY TYPE PERCENTAGE OF PROJECT AREA
FLOOR
INSTITUTIONAL 92% 5062 SF
NOT IN SCOPE 8% 469 SF
100% 5531 SF
Grand total 100% 5531 SF
LICENSING RULES FOR CHILD CARE CENTERS
LICENSING AND REGULATORY AFFAIRS (LARA)
BUREAU OF COMMUNITY AND HEALTH SYSTEMS
CHILD CARE LICENSING DIVISION
R 400.8350 TOILETS; HAND WASHING SINKS.
RULE 350
(1) A CENTER SHALL PROVIDE TOILET AND HAND WASHING SINKS AS FOLLOW
(A) A CENTER OPERATING WITH CHILDREN IN ATTENDANCE LESS THAN 5
CONTINUOUS HOURS A DAY SHALL PROVIDE AT LEAST 1 TOILET AND
WASHING SINK FOR EVERY 20 CHILDREN OR FRACTION THEREOF.
(B) A CENTER OPERATING WITH CHILDREN IN ATTENDANCE 5 OR MORE
CONTINUOUS HOURS A DAY SHALL PROVIDE AT LEAST 1 TOILET AND
WASHING SINK FOR EVERY 15 CHILDREN OR FRACTION THEREOF.
CHILD OCCUPANT LOAD: 134 OCCUPANTS
9 CHILDREN'S WATER CLOSETS REQUIRED
9 CHILDREN'S SINKS REQUIRED
9 CHILDREN SINKS PROVIDED + 2 ADULT SINKS W/STOOLS = 11 TOTAL
10 CHILDREN TOILETS PROVIDED + 1 ADULT TOILETS = 11 TOTAL
CORRIDOR
WOMENS
RESTROOM
STORAGE
INFANT AREA
STORAGE
MENS RESTROOM
STAFF RESTROOM
MECH ROOM
OFFICE
VESTIBULE
LOBBY
OFFICE
KITCHEN
3-4 YR OLDS AREA
STORAGE
RESTROOM
= COMMON AREAS/ ANCILLARY SPACES
NO LAYOUT CHANGES - 1,421 SQ.FT.
= STAFF/ OFFICE - NO LAYOUT CHANGES
199 SQ.FT.
= NEW RESTROOM LAYOUTS
525 SQ.FT.
= CHILD CARE AREA - SOME LAYOUT CHANGES
4,664 SQ. FT.
= NEW KITCHEN / LAUNDRY LAYOUT
390 SQ.FT.
© 2024 Driven Design Studio, All Rights Reserved.
Driven Design Studio PLLC
117 West Michigan Avenue
Battle Creek, MI 49017
(269) 753-8040 cody@drivendesignstudio.com
PROJECT NUMBER
STAMP
SCALE
DATE
DRAWN BY
PROJECT ADDRESS
PROJECT NAME
ARCHITECTURE/INTERIOR DESIGN
THIS DOCUMENT IS THE EXCLUSIVE
PROPERTY OF DRIVEN DESIGN. THE
DOCUMENT & THE INFORMATION IT
CONTAINS MAY NOT BE REPRODUCED
OR USED FOR OTHER THAN THE
SPECIFIC PROJECT FOR WHICH IT WAS
PREPARED WITHOUT THE EXPLICIT
CONSENT OF DRIVEN DESIGN.
OWNER
ISSUE
10/17/2025 9:32:44 AM
1/8" = 1'-0"
T006
AREA PLANS
VALENTINE CENTER
75 IRVING PARK DR, BATTLE CREEK, MI
49037
CMN
2025.024
City of Battle Creek
10 N Division St
Battle Creek, MI
(269) 966-3355
CONSTRUCTION DOCUMENTS
X
1/8" = 1'-0"T006
1 FIRST FLOOR AREA PLAN
AXIS 4-MEGAPIXEL OUTDOOR CAMERA OR EQUIVALENT
AXIS 2-MEGAPIXEL INDOOR CAMERA OR EQUIVALENT
SECURITY LEGEND
OUTDOOR LED LIGHT FIXTURE
*SECURITY PLANS ARE SHOWN SCHEMATICALLY, A
SECURITY CONSULTANT TO ENSURE ALL AREAS OUTSIDE
OF THE BATHROOMS ARE VISIBLE ON THE INTERIOR AND
EXTERIOR BY CAMERAS
MONITOR AND PRINTER
DVR LOCKBOX
LIMITED ACCESS AREA
RESTRICTED ACCESS AREA
PUBLIC ACCESS AREA
STORAGE
INFANT AREA
STORAGE
WOMENS
RESTROOM
MENS RESTROOM
STAFF RESTROOM
MECH ROOM
OFFICE
CORRIDOR
VESTIBULE
LOBBY
OFFICE
KITCHEN
STORAGE
RESTROOM
3-4 YR OLDS AREA
EXIT/ STORAGE
CLASSROOM 2
CLASSROOM 3
EXIT / STORAGE
CLASSROOM 4
CLASSROOM 1
CORRIDOR
© 2024 Driven Design Studio, All Rights Reserved.
Driven Design Studio PLLC
117 West Michigan Avenue
Battle Creek, MI 49017
(269) 753-8040 cody@drivendesignstudio.com
PROJECT NUMBER
STAMP
SCALE
DATE
DRAWN BY
GENERAL NOTES
PROJECT ADDRESS
PROJECT NAME
ARCHITECTURE/INTERIOR DESIGN
THIS DOCUMENT IS THE EXCLUSIVE
PROPERTY OF DRIVEN DESIGN. THE
DOCUMENT & THE INFORMATION IT
CONTAINS MAY NOT BE REPRODUCED
OR USED FOR OTHER THAN THE
SPECIFIC PROJECT FOR WHICH IT WAS
PREPARED WITHOUT THE EXPLICIT
CONSENT OF DRIVEN DESIGN.
OWNER
ISSUE
10/17/2025 9:32:46 AM
As indicated
T007
SECURITY PLAN
VALENTINE CENTER
75 IRVING PARK DR, BATTLE CREEK, MI
49037
CMN
2025.024
City of Battle Creek
10 N Division St
Battle Creek, MI
(269) 966-3355
CONSTRUCTION DOCUMENTS
X
1/8" = 1'-0"T007
1 FIRST FLOOR SECURITY PLAN
EXISTING SECURITY SHOWN FOR REFERENCE, THE SECURITY IS TO BE MONITORED BY THE CITY OF BATTLE CREEK.
EXISTING POND TO REMAIN
EXISTING BUILDING TO REMAIN
EXISTING PARKING TO REMAIN
EXISTING SIDEWALK TO REMAIN
EXISTING GREENSPACE TO REMAIN
EXISTING GREENSPACE TO REMAIN
EXISTING FENCE TO REMAIN TYP.
IR
V
IN
G
P A
R K
D R
EXISTING KNOX BOX
REMOVE AND DISPOSE OF ALL
EXISTING PLAYGROUND EQUIPMENT
M
IN
10' - 0" MAX. 10' - 0" MAX.
TENSION BANDS
TENSION BAR
3 - 1/2" DIA. TERMINAL
POST (GALVANIZED
STEEL PIPE)
CORNER POST CAP (TYP.)
RAIL END ASSEMBLY LINE POST CAP (TYP.) 1-3/4" DIA. TOP RAIL
(GALVANIZED STEEL PIPE)
4' - 0" - 9 GA. 2"
MESH GALV. CHAIN
LINK FENCE
# 6 GA. TENSION WIRE
6" DIA. 6,000 P.S.I. (28
DAYS) CONCRETE PIER
ATEACH POST (TYP.)
GRANULAR MATERIAL
EXISTING GRADE
8" DI. 6,000 P.S.I. (28
DAYS) CONCRETE PIERS
AT CORNER POSTS (TYP.)
M A
X
1' - 0"
REPLACE DAMAGED FENCING AS REQUIRED
© 2024 Driven Design Studio, All Rights Reserved.
Driven Design Studio PLLC
117 West Michigan Avenue
Battle Creek, MI 49017
(269) 753-8040 cody@drivendesignstudio.com
PROJECT NUMBER
STAMP
SCALE
DATE
DRAWN BY
PROJECT ADDRESS
PROJECT NAME
ARCHITECTURE/INTERIOR DESIGN
THIS DOCUMENT IS THE EXCLUSIVE
PROPERTY OF DRIVEN DESIGN. THE
DOCUMENT & THE INFORMATION IT
CONTAINS MAY NOT BE REPRODUCED
OR USED FOR OTHER THAN THE
SPECIFIC PROJECT FOR WHICH IT WAS
PREPARED WITHOUT THE EXPLICIT
CONSENT OF DRIVEN DESIGN.
OWNER
ISSUE
10/17/2025 9:32:47 AM
As indicated
C100
ARCHITECTURAL SITE PLAN AND DETAILS
VALENTINE CENTER
75 IRVING PARK DR, BATTLE CREEK, MI
49037
CMN
2025.024
City of Battle Creek
10 N Division St
Battle Creek, MI
(269) 966-3355
CONSTRUCTION DOCUMENTS
X
1. EXISTING BUILDING TO REMAIN ON THE EXISTING SITE
2. THE UTILITIES THAT ARE CURRENTLY CONNECTED TO THE BUILDING ARE TO REMAIN
3. CONTACT MISS DIG TO LOCATE ALL EXISTING UTILITIES BEFORE DOING ANY SITE WORK
4. EXISTING VEGETATION TO REMAIN ON THE SITE, TRIM AS REQUIRED
5. REUSE THE EXISTING KNOX BOX AT THE BUILDING ENTRY. REPLACE THE KEYS AS REQUIRED.
6. WORK WITHIN THE STREET TO BE DONE IN ACCORDANCE WITH THE REQUIREMENTS OF THE AGENCIES HAVING
JURISDICTION.
7. PERMITS, TESTING, BONDS & INSURANCES ETC., SHALL BE PAID FOR BY THE CONTRACTOR. CITY INSPECTION
FEES SHALL BE PAID FOR BY THE OWNER.
PARKING REQUIREMENTS
ADULT AND CHILD DAYCARE FACILITIES: 2 SPACES, PLUS 1 SPACE PER 8 ADULTS OR CHILDREN OF LICENSED
AUTHORIZED CAPACITY; PLUS, 1 DROP-OFF SPACES PER 8 ADULTS OR CHILDREN OF LICENSED AUTHORIZED
CAPACITY.
THE EXISTING PARKING LOT IS TO REMAIN, IT IS OWNED BY THE CITY OF BATTLE CREEK AND THERE ARE NO
PROPOSED CHANGES TO THE LOT.
1" = 20'-0"C100
1 SITE PLAN
3/4" = 1'-0"C100
2 CHAIN LINK FENCE
LANDSCAPE REQUIREMENTS
"WHENEVER ANY YARD (FRONT, SIDE, OR REAR) OF A USE OTHER THAN SINGLE OR TWO-FAMILY RESIDENTIAL, IS NOT DESIGNATED FOR A BUILDING, OFF-STREET PARKING, LOADING OR UNLOADING, OR OTHER PURPOSE
REQUIRED BY THE ZONING DISTRICT REQUIREMENTS, SUCH YARD SHALL BE IMPROVED WITH EITHER NATURAL OR
LIVING GROUNDCOVER INCLUDING GRASS, PLANT MATERIAL, ROCKS, STONES, MULCH, ETC."
LEGAL DESCRIPTION
WILLIS ADD POB 66 FT N OF NE COR LOT 15-N 578 FT-NELY 648 FT-W 1101.5 FT-S 714FT-W 96.5FT-S 1 32FT-W 66FT-S
66FT-W 66 FT-S 280 FT-E 1176 FT TO POB 30 AC +/- ACRES M/L
GENERAL NOTES
VESTIBULE
CRAFTS AND
WARMING CENTER
STORAGE
MENS RESTROOM
WOMENS
RESTROOM
KITCHEN
OFFICE
STORAGE
WOMENS
RESTROOM
READING ROOM
STORAGE
MENS RESTROOM
CORRIDOR
MECH ROOM
COAT CLOSET
LOBBY
RECREATION
ROOM
CORRIDOR
45' - 0 5/8"
/2
29' - 2 1/4"12' - 0 1/2"
/4
/4
/8
/8
/4
10' - 6 1/4" 18' - 5 1/4"
19' - 0 1/4"8' - 11"16' - 7 3/8"9' - 10 3/8"
73' - 3 1/2"
45' - 2"13' - 4 1/2"
/2
/8
© 2024 Driven Design Studio, All Rights Reserved.
Driven Design Studio PLLC
117 West Michigan Avenue
Battle Creek, MI 49017
(269) 753-8040 cody@drivendesignstudio.com
PROJECT NUMBER
STAMP
SCALE
DATE
DRAWN BY
GENERAL NOTES
PROJECT ADDRESS
PROJECT NAME
ARCHITECTURE/INTERIOR DESIGN
THIS DOCUMENT IS THE EXCLUSIVE
PROPERTY OF DRIVEN DESIGN. THE
DOCUMENT & THE INFORMATION IT
CONTAINS MAY NOT BE REPRODUCED
OR USED FOR OTHER THAN THE
SPECIFIC PROJECT FOR WHICH IT WAS
PREPARED WITHOUT THE EXPLICIT
CONSENT OF DRIVEN DESIGN.
OWNER
ISSUE
10/17/2025 9:32:47 AM
1/8" = 1'-0"
A000
EXISTING FLOOR PLANS
VALENTINE CENTER
75 IRVING PARK DR, BATTLE CREEK, MI
49037
CMN
2025.024
City of Battle Creek
10 N Division St
Battle Creek, MI
(269) 966-3355
CONSTRUCTION DOCUMENTS
X
EXISTING PLANS AND DIMENSIONS ARE SHOWN FOR REFERENCE ONLY
1/8" = 1'-0"A000
1 FIRST FLOOR EXISTING PLAN
REMOVE ALL FIXTURES
AND FINISHES IN THE
BATHROOMS
COMPLETELY
REMOVE ALL FIXTURES
AND FINISHES IN THE
BATHROOMS
COMPLETELY
REMOVE ALL
EXISTING CASEWORK,
FINISHES, AND
FIXTURES IN KITCHEN
REMOVE RAISED
PLATFORM AND
SUPPORTING
FEATURES
COMPLETELY
REMOVE ALL FIXTURES
AND FINISHES IN THE
BATHROOMS
COMPLETELY
GENERAL DEMOLITION NOTES
• REMOVE ALL EXISTING FLOORING BACK TO A LEVEL BASE
• REMOVE ALL WALL FINISHES BACK TO A LEVEL BASE OR PRIME
EXISTING WALLS AT THIS PHASE
• REMOVE AND DISPOSE OF ALL EXISTING CEILING GRIDS AND TILES
• REMOVE ALL PERMANENTLY MOUNTED EXTERIOR PLAYGROUND
EQUIPMENT AND DISPOSE OF AS REQUIRED
REMOVE ALL
EXISTING
CASEWORK,
FINISHES,
AND
CAMERA
SYSTEM
BASIS OF DESIGN, REMOVE
EXISTING ENTRY
STOREFRONT DOORS AND
REPLACE, ALTERNATE:
REPLACE GLAZING AS WELL
BASE BID IS TO RELOCATE DOOR
(103) TO NEW LOCATION AND
INFILL CURRENT LOCATION.
ALTERNATE IS TO LEAVE EXISTING
DOOR (103) IN CURRENT
LOCATION.
1. REMOVE ALL DASHED WALLS, WINDOWS, AND DOORS COMPLETELY.
2. OWNER TO REMOVE ALL FURNISHINGS/ EQUIPMENT THAT THEY WISH TO RETAIN FROM THE AREAS OF
DEMOLITION/ CONSTRUCTION PRIOR TO THE START OF CONSTRUCTION WORK IN EACH AREA. OWNER TO
COORDINATE WITH CONTRACTOR REGARDING THE TIME SCHEDULE FOR THIS TO BE COMPLETED.
3. PATCH AND FILL ANY HOLES IN THE WALL CAUSED BY THE REMOVAL OF DOORS, WINDOWS, OR WALLS TO
MATCH SURROUNDINGS.
4. CONTRACTOR IS RESPONSIBLE FOR PROTECTING ALL SURFACES NOT BEING REMODELED IN THE PROJECT AND
IN THE PATH OF THE CONTRACTORS TRAVEL, SETUP AND/ OR PROJECT MATERIAL STORAGE. THE CONTRACTOR
MUST RETURN THE AREAS DISTURBED AS REQUIRED FOR ACCESS TO ITS PRE-EXISTING CONDITION.
5. ANY HAZARDOUS MATERIALS ARE TO BE REMOVED BY A LICENSED PROFESSIONAL IN THE STATE OF
MICHIGAN.
6. ALL SAFETY ISSUES RELATED TO DEMOLITION ARE THE RESPONSIBILITY OF THE CONTRACTOR AND MUST
COMPLY WITH ALL STATE, LOCAL, ENVIRONMENTAL AND LABOR LAWS DURING THE CONSTRUCTION OF THIS
PROJECT.
7. SEQUENCE DEMOLITION WITH STRUCTURAL WORK TO ASSURE SAFETY, PROVIDE SHORING AS REQ'D TO
ENSURE SAFE CONDITIONS EXIST. SHORING IS NOT SHOWN ON PLANS. STRUCTURAL ELEMENTS ARE TO
REMAIN, UNLESS NOTED OTHERWISE, COORDINATE WITH ARCHITECTURAL AND STRUCTURAL DRAWINGS.
8. ALL TRADES TO COORDINATE BETWEEN ONE ANOTHER TO AVOID CONFLICTS.
9. NOTATIONS ARE MADE IN VARIOUS PLACES ON THE DRAWINGS TO CALL ATTENTION TO DEMOLITION WHICH
IS REQUIRED. THESE DRAWINGS ARE NOT INTENDED TO SHOW EACH AND EVERY ITEM TO BE REMOVED.
CONTRACTOR SHALL REMOVE ALL MATERIALS RELATED TO THEIR RESPECTIVE TRADES AS REQUIRED TO PERMIT
THE CONSTRUCTION OF THE NEW WORK AS SHOWN.
10. THE CONTRACTOR SHOULD TAKE CARE DURING THE PROJECT TO NOT INTERRUPT THE USE IN AREAS NOT IN
SCOPE.
11. PRIOR TO ANY DIGGING ON OR AROUND THE SITE UTILITIES ARE TO BE LOCATED USING MISS DIG.
12. ALL RUBBISH AND DEBRIS FROM DEMOLITION IS TO BE REMOVED IMMEDIATELY FROM THE SITE AFTER
DEMOLITION. COORDINATE ALL DEMOLITION, DUMPSTER LOCATIONS, BARRICADING, PEDESTRIAN
PROTECTION MEASURES, ETC. WITH THE OWNER AND LOCAL MUNICIPALITY PRIOR TO COMMENCEMENT.
13. REMOVE ALL LIGHTING, WIRING, FIRE ALARM DEVICES, RECEPTACLES, AND SPEAKERS FROM WALLS AND
CEILINGS BEING REMOVED. COORDINATE WITH ARCHITECT AS REQUIRED. REMOVE ALL ABANDONED
EXPOSED CONDUIT AND WIRING BACK TO SOURCE. REMOVE WIRING BACK TO PANEL OR NEAREST
JUNCTION BOX. RE-LABEL CIRCUIT BREAKER AS SPARE, IN SCOPE OF WORK.
14. PROVIDE BLANK COVERPLATE OVER EMPTY OUTLET BOXES IF DEVICE IS REMOVED AND NOT REPLACED.
15. REMOVE ALL EXISTING HVAC, FIRE PROTECTION AND PLUMBING EQUIPMENT, PIPING BACK TO MAIN AND
ALL ASSOCIATED ACCESSORIES. SANITARY, STORM, AND VENT STACKS TO REMAIN, CAP ANY UNUSED AREAS.
16. SALVAGE MATERIALS AS REQUIRED IF PART OF THE SCOPE IS MATCHING MATERIALS OR INFILL MATERIALS AS
PART OF A RENOVATION PROJECT.
17. REMOVE ALL CEILINGS AND FLOOR FINISHES IN AREAS OF DEMOLITION U.N.O.
18. ALL EXISTING COLUMNS AND STRUCTURAL ELEMENTS TO REMAIN. ANY DISCREPANCIES THAT OCCUR IN THE
FIELD DURING DEMOLITION SHOULD BE BROUGHT TO THE ARCHITECT'S ATTENTION.
19. THE CONTRACTOR SHALL MAINTAIN THE JOB SITE TO BROOM CLEAN AT ALL TIMES.
20. THE OWNER WILL MAINTAIN OCCUPANCY OF SPACES ADJACENT TO AREAS OF DEMOLITION. THE
CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL POTENTIALLY DISRUPTIVE ACTIVITIES WITH THE
OWNER.
21. WHERE NEW ACT AND GYP. CEILING ARE SPECIFIED, EXISTING CEILINGS ARE TO BE REMOVED WHILE
SALVAGING AL EXISTING LIGHT FIXTURES. EXISTING LIGHT FIXTURES TO REMAIN IN OR NEAR EXACT
LOCATIONS THEY ARE SALVAGED FROM. CONTRACTOR TO COORDINATE AND GET APPROVAL OF
RECOMMENDED PLACEMENT OF EXISTING LIGHT FIXTURES FROM OWNER PRIOR TO INSTALLATION OF NEW
CEILINGS AND RE-INSTALLATION OF EXISTING LIGHT FIXTURES.
EXISTING WALL TO REMAIN
CONCRETE
WOOD BLOCKING
STEEL (LARGE SCALE)
PLASTER
RIGID INSULATION
PLYWOOD
ELEMENTS TO BE REMOVED
WALL LEGEND
CMU
EXTENT OF WORK
MILLWORK
2 HOUR PARTITION
1 HOUR PARTITION
MATERIAL LEGEND
© 2024 Driven Design Studio, All Rights Reserved.
Driven Design Studio PLLC
117 West Michigan Avenue
Battle Creek, MI 49017
(269) 753-8040 cody@drivendesignstudio.com
PROJECT NUMBER
STAMP
SCALE
DATE
DRAWN BY
PROJECT ADDRESS
PROJECT NAME
ARCHITECTURE/INTERIOR DESIGN
DEMOLITION NOTES
THIS DOCUMENT IS THE EXCLUSIVE
PROPERTY OF DRIVEN DESIGN. THE
DOCUMENT & THE INFORMATION IT
CONTAINS MAY NOT BE REPRODUCED
OR USED FOR OTHER THAN THE
SPECIFIC PROJECT FOR WHICH IT WAS
PREPARED WITHOUT THE EXPLICIT
CONSENT OF DRIVEN DESIGN.
OWNER
ISSUE
10/17/2025 9:32:47 AM
As indicated
A110
DEMOLITION PLANS
VALENTINE CENTER
75 IRVING PARK DR, BATTLE CREEK, MI
49037
CMN
2025.024
City of Battle Creek
10 N Division St
Battle Creek, MI
(269) 966-3355
CONSTRUCTION DOCUMENTS
X
1/8" = 1'-0"A110
1 FIRST FLOOR DEMOLITION PLAN
ALIGN
ALIGN
STORAGE
INFANT AREA
STORAGE
WOMENS
RESTROOM
MENS RESTROOM
STAFF RESTROOM
MECH ROOM
OFFICE
CORRIDOR
VESTIBULE
LOBBY
OFFICE
KITCHEN
RESTROOM
3-4 YR OLDS AREA
A130
A130
A130
EXIT/ STORAGE
118B
CR
108B
113C
112C
108A
118A
NOT IN SCOPE
NOT IN SCOPE
STORAGE
121 124
123122
113A 113B
112B
CLASSROOM 3
32' - 1 7/8" 10' - 0" 30' - 4"
23' - 11 7/8"
/4
/8
30' - 4"10' - 0"32' - 1 7/8"
CLASSROOM 2
EXIT / STORAGE
CLASSROOM 4
CLASSROOM 1
CORRIDOR
LAUNDRY ROOM
5' - 6"
NEW FENCE TO
SCREEN
MECHANICAL UNIT,
GC TO VERIFY
LENGTH NEEDED
/4
/2
/2
112A 3
PROVIDE
ACCESS
GATE
PROVIDE
ACCESS
GATE
B.O.D. NEW DOORS
IN EXISTING FRAMES,
ALTERNATE: PROVIDE
NEW GLAZING AND
DOORS
CR
100 101
4"2' - 9"4"2' - 9"
4"2' - 9"4"2' - 9"
HSS4X4X3/8 STEEL
COLUMNS SET ON
18"X18"X42" FTG.
HSS4X4X3/8 STEEL
COLUMNS SET ON
18"X18"X42" FTG.
REBUILD PLANTER AS
REQUIRED AFTER
INSTALLATION OF NEW
COLUMNS, EA. SIDE
BASE BID IS TO RELOCATE
DOOR (103) TO NEW
LOCATION AND INFILL
CURRENT LOCATION.
ALTERNATE IS TO LEAVE
EXISTING DOOR (103) IN
CURRENT LOCATION.
1. ALL GYPSUM BOARD THROUGHOUT IS TO BE 5/8" TYPE-X AS A MINIMUM.
2. ALL EXISTING INTERIOR WALLS THAT ARE TO REMAIN ARE TO BE PATCHED AS REQUIRED FROM NEW UTILITIES
OR GENERAL CONSTRUCTION.
3. INFILL OF EXISTING WALL OPENINGS IS TO RESULT IN FLUSH FINISHES ON BOTH SIDES OF THE WALL. UNLESS
OTHERWISE NOTED, USE APPROPRIATE STUD FRAMING TO ACHIEVE DESIRED FINISH.
4. INSTALL WOOD BLOCKING IN WALLS AS NECESSARY FOR INSTALLATION OF ALL CASEWORK, MIRRORS, TOWEL
BARS, SHOWER CURTAIN RODS, TOILET PAPER DISPENSERS, PAPER TOWEL HOLDERS, TOILET PARTITIONS, RAILINGS, AND ANY OTHER ACCESSORIES.
5. DRAWINGS ESTABLISH THE DESIGN INTENT OF WORK TO BE PERFORMED. ALL PRODUCTS SHALL BE INSTALLED IN
ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. ALL TRADES SHALL CAREFULLY
COORDINATE WORK OF ALL OTHER TRADES. CONTRACTORS SHALL BE RESPONSIBLE FOR FIELD VERIFYING
EXISTING CONDITIONS AND FOR VERIFYING THEM WITH THE CONTRACT DOCUMENTS. ANY DISCREPANCIES
OR CONFLICTS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT AND THE OWNER PRIOR
TO FABRICATION OR INSTALLATION.
6. VERIFY QUANTITY, SIZE, AND LOCATION OF ALL FLOOR, ROOF, AND WALL OPENINGS FOR ALL DISCIPLINES
INCLUDING BUT NOT RESTRICTED TO MECHANICAL AND ELECTRICAL WORK WITH THE APPROPRIATE TRADE.
PROVIDE ALL OPENINGS SHOWN OR REQUIRED FOR THE COMPLETION OF THE WORK. PROVIDE ALL LINTELS
REQUIRED FOR THESE OPENINGS PER SPECIFICATIONS.
7. DIMENSIONS PRECEDED BY +/- SHOULD BE REVIEWED AND ALL NECESSARY ADJUSTMENTS MADE PRIOR TO
FABRICATION AND/OR INSTALLATION OF AFFECTED WORK. NOTIFY ARCHITECT'S REPRESENTATIVE IF
DISCREPANCIES ARISE BEFORE PROCEEDING WITH THE WORK.
8. BATHROOM MIRRORS AND LIGHT FIXTURES ABOVE VANITIES SHALL BE CENTERED ON THE SINKS.
FRAMING DETAILS