The document is a comprehensive interior signage design intent package for the Grand Junction Regional Airport (GJRA) prepared by Gensler, a design firm located in Denver, Colorado. The project involves a detailed interior signage system spanning three levels of the airport, with a total of 148 distinct sign types including room identification, wayfinding, informational, warning, and specialized signs such as evacuation maps and restroom markers. The design intent package provides extensive specifications for sign fabrication, including material requirements, mounting instructions, typography standards, and placement guidelines, with signs designed to meet ADA compliance and airport-specific communication needs.
The signage package includes specific technical requirements for sign fabricators, emphasizing sustainable and resilient design practices. Gensler requires vendors to submit field-verified measurements, digital elevation drawings, and reference site photos, with a focus on diversity in vendor selection and environmental considerations. The project incorporates specific material specifications such as acrylic, aluminum, and stainless steel substrates, with precise color specifications using brands like Matthews Paint and 3M vinyl films. Fabricators must provide 5-year warranties on signs and finishes, comply with local green building codes, and follow detailed submission and quality assurance protocols. The project appears to be part of a broader airport renovation or modernization effort, with a strong emphasis on creating a cohesive, accessible, and environmentally conscious signage system.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| GJT_Exterior Signage Development - Version 2B.pdf | ||
| Grand Junction Regional Airport_Signage RFP_20250523.pdf | ||
| Gensler_Interior_Exterior_Pricing Form.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Grand Junction Regional Airport
Interior Signage Design Intent Package May 20, 2025
GJRA - Interior Signage Schedule_v1 Changelog
Date Version Number Changelog Note(s)
2025.05.20 Version 1.0 Design Intent Package - Interior Signage & Wayfinding
CHANGE LOG
Issue Date & Description By QA/QC v1.0 05.20.25 - Design Intent Initial Issue CF/MP RW
G0.1
NOTES:
ALL SITE CONDITIONS, LOCATION AND DIMENSIONS
MUST BE VERIFIED BY THE CONTRACTOR/INSTALLER
PRIOR TO FABRICATION.
MATERIAL, FINISH AND COLOR SAMPLES MUST BE
PROVIDED FOR GENSLER’S REVIEW AND APPROVAL
UPON REQUEST PRIOR TO FABRICATION, UNLESS
OTHERWISE SPECIFIED.
SHOP DRAWINGS MUST BE PROVIDED TO GENSLER FOR
REVIEW PRIOR TO FABRICATION, UNLESS OTHERWISE
SPECIFIED.
Scale As Noted
If this drawing is not on an 11”x17”sheet, then it has been revised from its original size.
Sheet Description
SPECIFICATIONS
Project Name
GRAND JUNCTION REGIONAL AIRPORT
INTERIOR SIGNAGE PACKAGE
Project Number 003.8017.009
© 2025 Gensler All drawings and written material appearing herein constitute original and unpublished work of the designer and may not be duplicated, used or disclosed without written consent of designer.
Grand Junction Regional Airport Interior Signage Package
1225 17th Street, #150 Denver, CO 80202
USA
SIGN DETAILS
SHEET TYPE NAME
G3.1 RG.01 Room ID - ADA G3.2 RG.03 Restroom ID - ADA G3.3 RG.05 EVAC Map - Elevator G3.4 RG.06 Exit Route Sign - ADA G3.5 RG.07 Stairwell Level ID - Code G3.6 RG.08 Floor Level ID - ADA G3.7 RG.09 In Case of Fire - ADA/Elevator G3.8 RG.10 Building Entry G3.10 RG.11 Maximum Occupancy Sign G3.11 RG.15 FEC/AED Blade Sign G3.12 RG.19 Area of Refuge G3.13 IN.03 Level Directory G3.14 IN.12 Restroom Wall Graphic G3.15 IN.20 Policy / Notice G3.16 IN.22 Information Sign G3.17 IN.24 Warning Information Sign G3.18 WF.02 Blade ID G3.19 WF.03 Freestanding Directional G3.20 WF.04 Wall Directional - SM G3.21 WF.05 Overhead Informational Sign - LG G3.22 WF.06 Overhead Directional G3.24 WF.07 Overhead Bag Claim G3.25 WF.08 Gate ID G3.26 EX.13 Exterior Room ID - ADA G3.27 EX.15 Exterior Information Sign G3.28 EX.16 Building Sign Letters
PROJECT DESCRIPTION
SHEET DESCRIPTION
G0.1 Changelog G0.2 Table of Contents G0.3 Specifications G0.5 Sign Submittal - Submittal Requirements G0.6 Field Survey (VIF) Requirements G0.7 Graphic Asset Standards G0.8 Color System & Finishes G0.9 Sign System Overview G0.10 Existing Signage Conditions
SIGN LOCATION PLANS
SHEET DESCRIPTION
G1.1 Level 1 - Interior Signage G1.2 Level 2 - Interior Signage G1.3 Level 3 - Interior Signage G1.4 Level 1 - Visual Message Schedule - Wayfinding Signage G1.5 Level 2 - Visual Message Schedule - Wayfinding Signage G1.6 Level 3 - Visual Message Schedule - Wayfinding Signage
SIGN SCHEDULE
SHEET DESCRIPTION
G2.1 Sign Summary - Interior Signage & Wayfinding G2.2 Sign Schedule - Level 1 Interior Signage Messaging G2.3 Sign Schedule - Level 2 Interior Signage Messaging G2.4 Sign Schedule - Level 3 Interior Signage Messaging
TABLE OF CONTENTS
Issue Date & Description By QA/QC v1.0 05.20.25 - Design Intent Initial Issue CF/MP RW
G0.2
NOTES:
ALL SITE CONDITIONS, LOCATION AND DIMENSIONS
MUST BE VERIFIED BY THE CONTRACTOR/INSTALLER
PRIOR TO FABRICATION.
MATERIAL, FINISH AND COLOR SAMPLES MUST BE
PROVIDED FOR GENSLER’S REVIEW AND APPROVAL
UPON REQUEST PRIOR TO FABRICATION, UNLESS
OTHERWISE SPECIFIED.
SHOP DRAWINGS MUST BE PROVIDED TO GENSLER FOR
REVIEW PRIOR TO FABRICATION, UNLESS OTHERWISE
SPECIFIED.
Scale As Noted
If this drawing is not on an 11”x17”sheet, then it has been revised from its original size.
Sheet Description
SPECIFICATIONS
Project Name
GRAND JUNCTION REGIONAL AIRPORT
INTERIOR SIGNAGE PACKAGE
Project Number 003.8017.009
© 2025 Gensler All drawings and written material appearing herein constitute original and unpublished work of the designer and may not be duplicated, used or disclosed without written consent of designer.
Grand Junction Regional Airport Interior Signage Package
1225 17th Street, #150
SPECIFICATIONS
PROJECT COORDINATION
A. Project Team Gensler 1225 17th Street Suite 150 Denver, Colorado 80202
Rebekah_Wagoner@gensler.com Chris_Fato@gensler.com Michael_Peirce@gensler.com
Requests for clarification of the meaning or content of the drawings may be addressed via phone or in writing to the Project Team.
B. Sign Detail Production Note This document contains typical details based on GJT’s signage design guidelines.
Fabricator shall match the finished signs already installed in Phase 1 project areas.
PART 1 - GENERAL
1.00 Code
A. It will be the responsibility of the Sign Fabricator to meet any and all local, state and federal code requirements when fabricating and installing signs, to include ADA (Americans with Disabilities Act) requirements where applicable.
1.01 Substitutions
A. The Sign Fabricator will be held to furnish, under Sign Fabricator’s agreement, all work as specified. All materials, paint colors, and articles of any kind necessary for the Work are subject to the approval of Gensler and GJT (Client), with coordination through General Contractor (GC). Approval shall be final and conclusive. All substitutions shall be governed by the Specifications.
1.02 Coordination with Construction Manager
A. The Sign Fabricator will coordinate on-site work, electrical hook-up connections and final sign placement with the Client Construction Manager.
Where structural support footing for signage is required on the Contract Documents, it shall be provided and installed by the Sign Fabricator, and all adjacent landscaping repairedas required.
1.03 Resilience
A. Gensler's Commitment:
1. Gensler promotes responsible and resilient Project design and implementation.
Resilient design enriches the human experience, promotes well-being, and ensures safety by making an informed selection of materials and products to mitigate negative product-cycle impacts while enhancing building performance.
2. Gensler has committed to elimination of Greenhouse Gasses from our Projects by 2030.
3. Gensler strongly encourages all partners to support these commitments.
B. Sustainable Requirements:
1. Volatile Organic Compound (VOC) Content for Paints and Coatings, Adhesives and Sealants: Comply with LEED BD+C v4.1 Low-Emitting Materials requirements.
2. Emissions Testing, Paints and Coatings, and Adhesives and Sealants: Provide laboratory test results for paints and coatings, and adhesives and sealants, indicating that they comply with requirements of the California Department of Public Health (CDPH) "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers," Version 2.0."
3. Material Contents, Health Product Declaration (HPD): Provide for each end use product a published, complete HPD with full disclosure of known hazards in compliance with the Health Product Declaration Open Standard.
4. Environmental Product Declaration (EPD): Provide an EPD, where available, that conforms to one of the disclosure types listed in below, in descending order of preference:
1) Product-specific Type III EPD (i.e., conforms to ISO 14025, 14040, 14044, and EN 15804 or ISO 21930 and has at least a cradle to gate scope).
2) Industry-wide (generic) EPD (i.e., conforms to ISO 14025, 14040, 14044, and EN 15804 or ISO 21930 and has at least a cradle to gate scope).
3) A publicly available, critically reviewed life-cycle assessment conforming to ISO 14044 (i.e., has at least a cradle to gate scope).
C. Inclusivity:
1. Gensler is committed to working with a diverse team of consultants and vendors, and Sign Fabricator or Vendor is strongly encouraged to consider the diversity (gender identity, race, ability, age, socioeconomic status, and culture) of its vendors and consultants in connection with its services for this Project, in addition to any applicable project requirements, or local, state, or federal guidelines regarding diversity, equity, and inclusion.
PART 2 - GENERAL SPECIFICATIONS
2.01 General Requirements
A. Provide building signage and monument signs in accordance with requirements of the Client Exterior Sign Program-Design Intent Drawings and Specifications and Sign Location Plan as provided by Gensler.
2.02 Sign Types and Characteristics
A. Refer to Design Intent Documents-Sign Type drawing sheets for precise definition and proposed message of each sign.
2.03 Time of Completion
A. Time is of the essence. Sign Fabricator shall complete all work in accordance with scheduled milestones. All activities shall be sequenced to coordinate with field progress. In providing a bid response, it is assumed that Sign Fabricator agrees to follow Project Schedule as provided in bid solicitation documents. This includes any adjusting and cleaning necessary resulting from the site installation.
2.04 References
A. UBC - United States Uniform Building Code B. National Association of Architectural Metal Manufacturers (NAAMM) “Metal Finishes Manual.”
C. American Welding Society (AWS) - AWS D1.1 “Structural Welding Code, Steel,” and AWS D1.2 “Structural Welding Code, Aluminum”.
D. Underwriters Laboratories Inc. (UL) - Standards for Safety, UL Publication 48 “Electric Signs.”
2.05 Submittals by Sign Fabricators
A. Schedules Sign Fabricator to provide schedules of shop drawings, submittal dates, and installation dates to meet the project completion deadlines for the project. Allow ten (10) working days for Gensler and Client to review and approve shop drawings and samples.
B. Shop Drawings Provided by Sign Fabricator & licensed Structural Engineer. Furnish elevations, details of fabrication and erection, including all materials, shapes, dimensions, finishes, anchorage, and method of connections. Show proper letter spacing and dimensions of letter heights. Submit per schedule, for approval. Provide two (3) prints of each drawing: deliver one (1) set to Gensler, one (1) set to Client, and one
(1) set to GC directly.
C. Color and Material Samples Submit samples as indicated in Colors / Materials Sheet. Submit per schedule, for approval. Provide three (3) sets of non-returnable samples of all materials, colors, and finishes as specified: deliver one (1) set to Gensler, one (1) set to Client, and one (1) set to GC directly.
D. Patterns and Lettering Submit for approval scaled proof of each sign layout on 11 x 17 paper. Layout must be represented using exact typeface and letterspacing as specified with solid black letterforms and graphic elements on a white background. Layout to be reviewed and approved by Gensler prior to fabrication.
E. Extra Materials Deliver to Client in manufacturer’s original packaging and store at the project site where directed.
E.1 Furnish five (5) replacement low voltage LED transformers of each type and size used in the internally illuminated monument sign units A1 & A2.
F. Supplementary Product Literature Submit for information. As requested, furnish within seven (7) days of request, manufacturer’s literature describing the general properties of each product to be used in the Work.
G. Submittal Requirements listed in Detail 02 on this page.
2.06 Permits by Sign Fabricator
A. Sign Fabricator shall make all submittals for permits; assisted by Client Construction Manager and GC and shall be responsible for paying all fees, making adjustments as required, or any task necessary for obtaining local building and installation Sign Permits for the proper execution of the work.
2.07 Quality Assurance
A. Mock-ups Provide a mock-up of each sign type requested for review. See Signage Prototype Section below.
Signs shall be mounted to temporary bases for viewing at Client site (location to be coordinated with Client Construction Manager). Refer to sign drawings for further information. Utilize the same materials including lighting and installation methods in the mock-up as intended for the final Work. Schedule the installation so that the mock-up may be examined for day time and night time review, and any necessary adjustments made, prior to commencing fabrication of the final Work. Replace unsatisfactory items as directed. When accepted, mock-up shall serve as the standard for materials, workmanship, and appearance for such Work throughout the project. Approved mock-ups can be used as first article signs.
B. Work-In-Progress Approvals Provide work-in-progress sign elements for review. Scheduled or unscheduled viewings at the Shop or Factory may be initiated as deemed necessary to ensure continued quality control and make any adjustments required during fabrication.
Unsatisfactory items are to be corrected by the Sign Fabricator as directed.
C. Regulatory Requirements Comply with applicable requirements of the laws, codes, ordinances and regulations of Federal, State and Municipal authorities having jurisdiction. Obtain necessary approvals and permits from all such authorities as required.
D. Markings and Labels Locate markings, labels, manufacturer names and other identifications so as to be concealed from public view and as acceptable by Gensler.
E. Final Location of Signs The location of signs as shown on Sign Location Plan is for general reference only and in some cases is not representative of the exact final location. Final locations of signs shall be field located in coordination with Client Construction Manager, GC and Gensler at the site. Sign Fabricator shall arrange for meetings at the site to accommodate direction of final locations according to project schedule.
F. Lettering The Sign Fabricator shall be responsible for the quality control of all lettering. All letterforms shall be crisp, sharp, free of nicks, ragged edges and discontinuous curves. All lettering shall conform to approved typeface, weight and letterspacing.
No substitutions of typeface foundry, brand or version or implementation technique will be accepted without prior approval.
F.1 Vinyl Die Cut Graphics All cutting and routing shall be executed in such a manner that all edges and corners of finished letterforms are true and clean. Letterforms with rounded positive or negative corners, nicked, cut, or ragged edges, etc., will not be accepted. All letterforms shall be so aligned as to maintain a baseline parallel to the sign format. Margins must be maintained as specified in drawings.
G. Quality of Workmanship The Sign Fabricator shall be responsible for the quality of all materials and workmanship required for the execution of this contract including materials and workmanship of any firm or individual who act as Sign Fabricator’s subcontractor.
All work under this contract shall be performed by skilled craftsmen under supervision of trained foremen, experienced in the trade of craft required to accomplish the Work and produce a product of high quality. Sign Contractor shall be responsible for providing up-to-date drawings, specifications, graphic schedule, etc., to all sub-contractors.
H. Dimensions Written dimensions on drawings shall have precedence over scaled dimensions.
Sign Fabricator shall verify and be responsible for all dimensions and conditions shown by these drawings. Shop details must be approved prior to fabrication.
I. Discrepancies The Client Construction Manager shall be notified by the Sign Fabricator of any discrepancies in the drawings or graphic message schedule, in field dimensions or conditions and/or changes required in construction details.
J. Rights to Design Sign Fabricator may not manufacture, reproduce, or exhibit these designs, or modify them for any other purpose outside of this current contract without written approval of Gensler and Client.
K. Resiliance Best Practices
1. Comply with local green building codes and client green building standards. At a minimum, manufacturers shall provide VOC content and emissions certification to show compliance with limits listed herein. Products with transparency declarations (Health Product Declarations, Declare, JUST labels, C2C certification, and EPDs) will be prioritized.
2. Recyclability: Clearly state the condition of the materials that can be recycled and their proper labeling
a. Refer to https://How2Recycle.org.
3. Comply with manufacturer's End of Life Disposal recommendations
2.08 Warranty
A. Warranties Submit to Client for Owner’s documentation, a 5-year written warranty (effective the date of final acceptance) covering all project signs, graphics and components.
Warranties to be signed by the Sign Fabricator and Installer, agreeing to repair or replace Work which has failed as a result of defects in materials or workmanship or installation. Upon notification of such defects, within the warranty period, make necessary repairs or replacement at the convenience of Client.
B. Linear Polyurethane Paint Factory Finish Warranty Submit to Client Construction Manager for Owner’s documentation. Furnish 5-year written warranty, warranting that the factory-applied linear polyurethane finishes will not develop excessive fading or excessive non uniformity of color or shade, and will not crack, peel, pit, corrode or otherwise fail as a result of defects in materials or workmanship within the following defined limits. Upon notification of such defects, within the warranty period, make necessary repairs or replacement at the convenience of Client.
B.1 “Excessive Fading” A change in appearance which is perceptible and objectionable as determined when visually compared with the original color range standards.
B.2 “Excessive Non-Uniformity” Non-uniform fading to the extent that adjacent panels have a color difference greater than the original acceptable color range.
B.3 “Will Not Pit or Otherwise Corrode” No pitting or other type of corrosion, discernible from a distance of 10 feet (3m), resulting from the natural elements in the atmosphere at the project site.
2.09 Maintenance
A. Maintenance and Operating Cut Sheets Submit 2 copies to Client for Owner’s documentation and 1 copy for Gensler’s documentation. Furnish complete cut sheets describing the materials, devices and procedures to be followed in operating, cleaning and maintaining the Work.
Include manufacturers’ brochures and parts lists describing the actual materials used in the Work, including metal alloys, finishes, electrical components and other major components. Assemble cut sheets for component parts into single folders/packages identified for each system.
PART 3 - PRODUCTS & EXECUTION
3.01 Sign Materials
A. Adhesives Silicone adhesive used for assembling signs, where necessary, shall be manufactured by Dow Corning or equal.
B. All Specified Metals B.1 Aluminum Aluminum shall be suitable for ornamental, architectural work. Surface finish shall be smooth, free of extrusion marks or imperfections. Alloy shall be selected to meet the structural requirements of the specific application.
C. Acrylic Sheet Plastic Use Acrylite® as manufactured by Evonik Cyro LLC, or equal. Thickness shall be as indicated on drawings. Contractor shall provide color and finish samples of all plastics for approval before fabrication; no substitution in color, thickness, or finish of plastics will be accepted without written approval. All plastics shall be of uniform color, translucence and illumination, as supplied by manufacturer. Any exposed edges of acrylic shall be finished so as no tooling marks are visible.
D. Concrete: Not Applicable
E. Fasteners Bolts, nuts, screws, washers, anchors and other devices required to complete the work shall be concealed where possible, except that no hardware shall be visible on sign faces. Same basic metal or alloy as the metal fastened, and finished to match in color and texture. Stainless steel 300 series alloy where used to join dissimilar materials.
F. Welding Electrodes and Filler Metal Provide the alloy and type required for strength, workability, compatibility and color match after grinding smooth and finishing the fabricated product.
3.02 Sign Products
A. Typefaces:
1. As noted in Typography details
3.04 Finishing Materials
A. Linear Polyurethane Coatings Provide the following, or other products as acceptable:
A.1 Acrylic Linear Polyurethane Enamel Two components, acrylic aliphatic isocyanate/acrylic polyurethane having ultraviolet (UV) inhibitors and engineered for exterior application by Matthews Paint Company or approved equal.
A.2 Primer for Aluminum Two part component primer: One-coat Matthews 74-734 and 74-735 Metal Pretreat at .25 mils dry film thickness or one-coat Matthews 74-793 Spray Bond at .15 to .25 mils dry film thickness or Wyandotte/AKZO Grip-Guard Wash Primer (2Afy-31284) with Grip-Guard Wash Primer Hardener (10AFK-31285) combined and applied per manufacturer’s specifications or approved equal (primer) for the application of the pre-approved and pre-formulated paint system.
B. Vinyl Die-Cut and Pattern Cut-out Graphics Use 3M Company cast vinyl films, where specified.
B.1 Use translucent self adhesive vinyl film manufactured as specified. Colors as indicated in document.
3.05 Fabrication of Signs, Components and Supports
A. General Provide custom manufactured sign assemblies, components completely fabricated and finished at factory before delivery to site. Construct to accurate detail and dimensions as shown and as reviewed on shop drawings. Fit and assemble the Work at shop to the greatest extent possible, and mark the components as required to facilitate assembly during installation. Exposed fasteners on finished faces will not be allowed, unless specifically indicated.
Waviness and oil canning of surfaces is not acceptable. Minimum material thickness is to be 0.090 inches. Conceal wiring, conduct and other electrical items within sign enclosures.
B. Lettering Cut and rout in a manner to produce true and clean edges and corners of finished letterforms. Letterforms having rounded positive or negative corners, nicked, cut, or ragged edges are not acceptable. Align letter forms to maintain a baseline parallel to the sign format. Maintain margins as indicated on Drawings.
C. Seams and Joints Provide sign faces complete without material joints. Added joints in other sign components shall be ground filled and finished flush and smooth with adjacent work. Such seams shall be invisible after final finish has been applied. Spot welded joints shall not be visible on exterior of signs after final finish has been applied. No gaps, light leaks, waves, or oil canning will be permitted in work.
D. Metal Signs and Supports Fabricate exposed surfaces uniformly flat and smooth, without distortion, pitting, or other blemishes. Grind exposed welds and rough areas to make flush with adjacent smooth surfaces.
D.1 Welding Make welds continuous. Comply with American Welding Society, Aluminum Association, and copper Development Association standards for the type of metal.
D.2 Fasteners Use exposed fasteners only where indicated. Perform drilling and tapping at shop.
D.3 Dissimilar Materials Where metal surfaces will be in contact with dissimilar materials, coat the surfaces with epoxy paint or plate with zinc chromate, or provide other means of dielectric separation as recommended by manufacturer to prevent galvanic corrosion.
E. Hardware Provide all incidental hardware necessary for the proper functioning of signs.
External hardware shall conform to the external appearance of the sign.
F. Supports and Internal Structural Sign Fabricator shall provide engineered sign supports anchored to poured in place concrete footings where required and to meet requirements of applicable building codes.
3.06 Shop Application of Sign Finishes
A. Sign Graphics Provide the letters, numerals, symbols, and other graphics markings, using the finish materials shown on drawings. Apply the graphics neatly, uniformly proportioned and spaced, and accurate within the dimensions indicated. Prepare the substrate surfaces and apply finish materials in accordance with manufacturers’ instructions.
B. Metal Finishes Remove scratches, abrasions, dents and other blemishes before applying finish.
C. Linear Polyurethane Finishes Clean the surfaces as required for proper adhesion of coatings. Use 3M Co.
“Scotch Brite” pads with cleanser and water, and/or chemically treat as recommended by paint manufacturer to remove deleterious film or residue.
C.1 Linear Polyurethane Paint Provide pretreatment and primer in accordance with manufacturer’s recommendation. Add ultra violet inhibitors to paint subject to sunlight exposure.
C.2 Clear Linear Polyurethane Finish Provide pretreatment, primer, and matte or semi-gloss finish coatings in accordance with manufacturer’s recommendations. Apply 1.5 to 2.0 mils (0.0375 to 0.050 mm) dry film thickness.
3.07 Graphic Application
A. Preparation Surfaces to receive the graphic markings shall be clean, dry, and otherwise made ready for application of the materials. Accurately measure and lay out the required marking configurations as indicated on drawings.
B. Vinyl Die-cut and Pattern-cut Graphics Use pressure sensitive, non-yellowing, non-peeling and weather resistant vinyl adhesive letters or images, custom color silkscreened as required, die cut from ScotchLite as manufactured by 3M company. Apply in strict accordance with manufacturer’s instructions. Make uniformly smooth and free from bubbles, wrinkles, stretching and blemishes.
C. Silk-screened Graphics Silkscreened enamel ink to be applied using appropriate screens, applied without build-up or bleeding of the coating. Comply with coating manufacturer’s application instructions. Apply the markings minimum 3 mils (0.075 mm) dry film thickness or as recommended by the manufacturer to obtain solid coatings without voids.
D. Digital Printing:
All digitally printed graphics to be printed directly to specified materials to produce bonded, durable graphics. Printers must be able to output a full gamut of spot and process colors as defined under the Pantone Matching System including opaque white. All digitally printed Graphics to be output at a minimum of 300 dpi resolution, and all Digital graphics files to contain minimum 300 dpi at full scale.
Printing Note: All digital imaging to be done on Durst RhoP10 UV Hybrid flatbed printer or equal. Printing direct to substrate: Print with premium ink and white under and over.
E. Masked and Sprayed Graphics Spray graphics onto face of panel and or building substrate using computer-cut stencils to mask background. Masked and sprayed graphics shall have same sheen as surrounding material and shall be indistinguishable in finish from surrounding material. Execute sprayed graphics so that edges and corners of finish letter forms and graphic devices are true and clean. Any rounded positive or negative corners, edge build up, bleeding, or any other imperfections will be rejected. Sprayed graphics to be 100% opaque and evenly applied without pin holes, scratches, orange peeling, or application marks. Spraying with any “show thru” of background colors will not be accepted.
3.07 Waste Management
A. Develop, and submit to Gensler, a waste management plan according to ASTM E1609. Plan shall consist of waste identification, waste reduction work plan, and cost/revenue analysis. Distinguish between demolition and construction waste.
Indicate quantities by weight or volume, but use same units of measure throughout waste management plan.
B. Waste Identification: Indicate anticipated types and quantities of demolition, site-clearing, and construction waste generated by the Work. Include estimated quantities and assumptions for estimates.
1. As packaging of the materials becomes waste on site, it should be properly labeled for recycling.
C. Waste Reduction Work Plan: List of each type of waste and whether it will be salvaged, recycled, donated, or disposed of in landfill or incinerator. Include points of waste generation, total quantity of each type of waste, quantity for each means of recovery, handling and transportation procedures, and initiatives to reduce packaging.
D. Waste Diversion Plan: Include all the initiatives to avoid sending waste to a landfill or incinerator, by recycling, donating, salvaging, retrofitting, refurbishing if the materials allow it.
1. Handling and Transportation Procedures: Include method that will be used for separating recyclable waste including sizes of containers, container labeling, and designated location where materials separation will be performed.
E. Waste Disposal Management: Where there is no other option than to dispose of it, document how the waste will be disposed of, in a landfill or incinerated.
1. Disposed Materials: Indicate how and where materials will be disposed of.
Include name, address, and telephone number of each landfill and incinerator facility.
F. Cost/Revenue Analysis: Indicate total cost of waste disposal as if there was no waste management plan and net additional cost or net savings resulting from implementing waste management plan. Include the following:
1. Total quantity of waste.
2. Estimated cost of disposal (cost per unit). Include hauling and tipping fees and cost of collection containers for each type of waste.
3. Total cost of disposal (with no waste management).
4. Revenue from salvaged materials.
5. Revenue from recycled materials.
6. Savings in hauling and tipping fees by donating materials.
7. Savings in hauling and tipping fees that are avoided.
8. Handling and transportation costs. Include cost of collection containers for each type of waste.
9. Net additional cost or net savings from waste management plan.
PART 4 - INSTALLATION & APPROVAL
4.01 Examination
A. Verification of Conditions Sign Fabricator must examine the areas to receive the Work and the conditions under which the Work would be performed. Contractor shall remedy conditions detrimental to the proper and timely completion of the Work. Do not proceed until unsatisfactory conditions have been corrected.
B. Pre-Installation Meeting A pre-installation meeting will be held with Gensler, Client, GC, Sign Fabricator and Installer to mutually agree on all installation details, placement, etc.
4.02 Installation of Signs
A. General Complete installation shall be in accordance with manufacturers’ printed instructions and accepted shop drawings, to produce Work complying with the Contract Documents. The Sign Fabricator will be responsible for daily clean-up of signs and their areas of work.
B. Union Labor Requirement Confirm with Client Construction Manager and GC whether all tradesmen and installers performing Work on site must be union-certified. If required, the Sign Fabricator shall be responsible for adherence to all union standards and conditions as required. The Sign Fabricator to provide documentation to Client and Construction Manager on request.
C. Erection of Signs Set and attach the Work accurately in location, alignment and elevation, plumb, level and true, as measured from established reference points and from other Work already in place. Fit components accurately together to form tight joints and secure connections. Coordinate, through the Client Construction Manager and Gensler with other trades and make connections of illuminated signs to electrical service. Test illuminated sign components and adjust operation for proper performance.
4.03 Adjusting
A. Neatly repair minor blemishes or marring on finished surfaces so that repairs are imperceptible. Completely replace components having permanent non-removable scratches, stains, or other defacement.
4.04 Cleaning
A. Upon completion of the Work, remove unused materials, debris, containers, footing forms and equipment from the project site. Remove protective coverings and clean the exposed surfaces of the Work to remove dirt, stains and other substances, by methods as recommended by manufacturers.
4.05 Installation of Graphic Wallcovering
A. Preparation:
1. Fabricator or Vendor to comply with manufactures written preparation instruction for all types of wall surfaces.
2. Surfaces to receive the graphic markings shall be clean, dry, and otherwise made ready for application of the materials. Accurately measure and lay out the required marking configurations as indicated on drawings. Sufficient time will be provided for materials/prints to acclimate to local temperatures and conditions. If needed, walls will be painted 72 hours ahead of installation to provide sufficient time for off-gassing and drying.
B. Wall finishes:
1. Sign Fabricator or Vendor is to verify all wall finishes receiving applied graphics or signage meet the required finish level necessary prior to installing graphics.
Provide Level 5 gypsum board finish on finished surfaces.
2. Check painted surfaces for pigment bleeding. Sand gloss, semigloss, and eggshell finish with fine sandpaper.
3. Acclimatize wall-covering materials by removing them from packaging in the installation areas not less than 24 hours before installation.
C. Installation:
1. Install graphic wallcovering in accordance with the manufacturer's written instructions.
2. Install graphic wallcoverings without lifted or curling edges and without visible shrinkage.
3. Trim edges and seams for color uniformity, pattern match, and tight closure.
Butt seams without overlaps or gaps between strips.
4. Protect all exposed edges of graphic wallcoverings with corner guards as scheduled.
D. Fully bond graphic wallcoverings to substrate. Remove air bubbles, wrinkles, blisters, and other defects.
END OF SPECIFICATIONS
Issue Date & Description By QA/QC v1.0 05.20.25 - Design Intent Initial Issue CF/MP RW
G0.3
NOTES:
ALL SITE CONDITIONS, LOCATION AND DIMENSIONS
MUST BE VERIFIED BY THE CONTRACTOR/INSTALLER
PRIOR TO FABRICATION.
MATERIAL, FINISH AND COLOR SAMPLES MUST BE
PROVIDED FOR GENSLER’S REVIEW AND APPROVAL
UPON REQUEST PRIOR TO FABRICATION, UNLESS
OTHERWISE SPECIFIED.
SHOP DRAWINGS MUST BE PROVIDED TO GENSLER FOR
REVIEW PRIOR TO FABRICATION, UNLESS OTHERWISE
SPECIFIED.
Scale As Noted
If this drawing is not on an 11”x17”sheet, then it has been revised from its original size.
Sheet Description
SPECIFICATIONS
Project Name
GRAND JUNCTION REGIONAL AIRPORT
INTERIOR SIGNAGE PACKAGE
Project Number 003.8017.009
© 2025 Gensler All drawings and written material appearing herein constitute original and unpublished work of the designer and may not be duplicated, used or disclosed without written consent of designer.
Grand Junction Regional Airport Interior Signage Package
1225 17th Street, #150
SPECIFICATIONS
PROJECT COORDINATION
A. Project Team Gensler 1225 17th Street Suite 150 Denver, Colorado 80202
Rebekah_Wagoner@gensler.com Chris_Fato@gensler.com Michael_Peirce@gensler.com
Requests for clarification of the meaning or content of the drawings may be addressed via phone or in writing to the Project Team.
B. Sign Detail Production Note This document contains typical details based on GJT’s signage design guidelines.
Fabricator shall match the finished signs already installed in Phase 1 project areas.
PART 1 - GENERAL
1.00 Code
A. It will be the responsibility of the Sign Fabricator to meet any and all local, state and federal code requirements when fabricating and installing signs, to include ADA (Americans with Disabilities Act) requirements where applicable.
1.01 Substitutions
A. The Sign Fabricator will be held to furnish, under Sign Fabricator’s agreement, all work as specified. All materials, paint colors, and articles of any kind necessary for the Work are subject to the approval of Gensler and GJT (Client), with coordination through General Contractor (GC). Approval shall be final and conclusive. All substitutions shall be governed by the Specifications.
1.02 Coordination with Construction Manager
A. The Sign Fabricator will coordinate on-site work, electrical hook-up connections and final sign placement with the Client Construction Manager.
Where structural support footing for signage is required on the Contract Documents, it shall be provided and installed by the Sign Fabricator, and all adjacent landscaping repairedas required.
1.03 Resilience
A. Gensler's Commitment:
1. Gensler promotes responsible and resilient Project design and implementation.
Resilient design enriches the human experience, promotes well-being, and ensures safety by making an informed selection of materials and products to mitigate negative product-cycle impacts while enhancing building performance.
2. Gensler has committed to elimination of Greenhouse Gasses from our Projects by 2030.
3. Gensler strongly encourages all partners to support these commitments.
B. Sustainable Requirements:
1. Volatile Organic Compound (VOC) Content for Paints and Coatings, Adhesives and Sealants: Comply with LEED BD+C v4.1 Low-Emitting Materials requirements.
2. Emissions Testing, Paints and Coatings, and Adhesives and Sealants: Provide laboratory test results for paints and coatings, and adhesives and sealants, indicating that they comply with requirements of the California Department of Public Health (CDPH) "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers," Version 2.0."
3. Material Contents, Health Product Declaration (HPD): Provide for each end use product a published, complete HPD with full disclosure of known hazards in compliance with the Health Product Declaration Open Standard.
4. Environmental Product Declaration (EPD): Provide an EPD, where available, that conforms to one of the disclosure types listed in below, in descending order of preference:
1) Product-specific Type III EPD (i.e., conforms to ISO 14025, 14040, 14044, and EN 15804 or ISO 21930 and has at least a cradle to gate scope).
2) Industry-wide (generic) EPD (i.e., conforms to ISO 14025, 14040, 14044, and EN 15804 or ISO 21930 and has at least a cradle to gate scope).
3) A publicly available, critically reviewed life-cycle assessment conforming to ISO 14044 (i.e., has at least a cradle to gate scope).
C. Inclusivity:
1. Gensler is committed to working with a diverse team of consultants and vendors, and Sign Fabricator or Vendor is strongly encouraged to consider the diversity (gender identity, race, ability, age, socioeconomic status, and culture) of its vendors and consultants in connection with its services for this Project, in addition to any applicable project requirements, or local, state, or federal guidelines regarding diversity, equity, and inclusion.
PART 2 - GENERAL SPECIFICATIONS
2.01 General Requirements
A. Provide building signage and monument signs in accordance with requirements of the Client Exterior Sign Program-Design Intent Drawings and Specifications and Sign Location Plan as provided by Gensler.
2.02 Sign Types and Characteristics
A. Refer to Design Intent Documents-Sign Type drawing sheets for precise definition and proposed message of each sign.
2.03 Time of Completion
A. Time is of the essence. Sign Fabricator shall complete all work in accordance with scheduled milestones. All activities shall be sequenced to coordinate with field progress. In providing a bid response, it is assumed that Sign Fabricator agrees to follow Project Schedule as provided in bid solicitation documents. This includes any adjusting and cleaning necessary resulting from the site installation.
2.04 References
A. UBC - United States Uniform Building Code B. National Association of Architectural Metal Manufacturers (NAAMM) “Metal Finishes Manual.”
C. American Welding Society (AWS) - AWS D1.1 “Structural Welding Code, Steel,” and AWS D1.2 “Structural Welding Code, Aluminum”.
D. Underwriters Laboratories Inc. (UL) - Standards for Safety, UL Publication 48 “Electric Signs.”
2.05 Submittals by Sign Fabricators
A. Schedules Sign Fabricator to provide schedules of shop drawings, submittal dates, and installation dates to meet the project completion deadlines for the project. Allow ten (10) working days for Gensler and Client to review and approve shop drawings and samples.
B. Shop Drawings Provided by Sign Fabricator & licensed Structural Engineer. Furnish elevations, details of fabrication and erection, including all materials, shapes, dimensions, finishes, anchorage, and method of connections. Show proper letter spacing and dimensions of letter heights. Submit per schedule, for approval. Provide two (3) prints of each drawing: deliver one (1) set to Gensler, one (1) set to Client, and one
(1) set to GC directly.
C. Color and Material Samples Submit samples as indicated in Colors / Materials Sheet. Submit per schedule, for approval. Provide three (3) sets of non-returnable samples of all materials, colors, and finishes as specified: deliver one (1) set to Gensler, one (1) set to Client, and one (1) set to GC directly.
D. Patterns and Lettering Submit for approval scaled proof of each sign layout on 11 x 17 paper. Layout must be represented using exact typeface and letterspacing as specified with solid black letterforms and graphic elements on a white background. Layout to be reviewed and approved by Gensler prior to fabrication.
E. Extra Materials Deliver to Client in manufacturer’s original packaging and store at the project site where directed.
E.1 Furnish five (5) replacement low voltage LED transformers of each type and size used in the internally illuminated monument sign units A1 & A2.
F. Supplementary Product Literature Submit for information. As requested, furnish within seven (7) days of request, manufacturer’s literature describing the general properties of each product to be used in the Work.
G. Submittal Requirements listed in Detail 02 on this page.
2.06 Permits by Sign Fabricator
A. Sign Fabricator shall make all submittals for permits; assisted by Client Construction Manager and GC and shall be responsible for paying all fees, making adjustments as required, or any task necessary for obtaining local building and installation Sign Permits for the proper execution of the work.
2.07 Quality Assurance
A. Mock-ups Provide a mock-up of each sign type requested for review. See Signage Prototype Section below.
Signs shall be mounted to temporary bases for viewing at Client site (location to be coordinated with Client Construction Manager). Refer to sign drawings for further information. Utilize the same materials including lighting and installation methods in the mock-up as intended for the final Work. Schedule the installation so that the mock-up may be examined for day time and night time review, and any necessary adjustments made, prior to commencing fabrication of the final Work. Replace unsatisfactory items as directed. When accepted, mock-up shall serve as the standard for materials, workmanship, and appearance for such Work throughout the project. Approved mock-ups can be used as first article signs.
B. Work-In-Progress Approvals Provide work-in-progress sign elements for review. Scheduled or unscheduled viewings at the Shop or Factory may be initiated as deemed necessary to ensure continued quality control and make any adjustments required during fabrication.
Unsatisfactory items are to be corrected by the Sign Fabricator as directed.
C. Regulatory Requirements Comply with applicable requirements of the laws, codes, ordinances and regulations of Federal, State and Municipal authorities having jurisdiction. Obtain necessary approvals and permits from all such authorities as required.
D. Markings and Labels Locate markings, labels, manufacturer names and other identifications so as to be concealed from public view and as acceptable by Gensler.
E. Final Location of Signs The location of signs as shown on Sign Location Plan is for general reference only and in some cases is not representative of the exact final location. Final locations of signs shall be field located in coordination with Client Construction Manager, GC and Gensler at the site. Sign Fabricator shall arrange for meetings at the site to accommodate direction of final locations according to project schedule.
F. Lettering The Sign Fabricator shall be responsible for the quality control of all lettering. All letterforms shall be crisp, sharp, free of nicks, ragged edges and discontinuous curves. All lettering shall conform to approved typeface, weight and letterspacing.
No substitutions of typeface foundry, brand or version or implementation technique will be accepted without prior approval.
F.1 Vinyl Die Cut Graphics All cutting and routing shall be executed in such a manner that all edges and corners of finished letterforms are true and clean. Letterforms with rounded positive or negative corners, nicked, cut, or ragged edges, etc., will not be accepted. All letterforms shall be so aligned as to maintain a baseline parallel to the sign format. Margins must be maintained as specified in drawings.
G. Quality of Workmanship The Sign Fabricator shall be responsible for the quality of all materials and workmanship required for the execution of this contract including materials and workmanship of any firm or individual who act as Sign Fabricator’s subcontractor.
All work under this contract shall be performed by skilled craftsmen under supervision of trained foremen, experienced in the trade of craft required to accomplish the Work and produce a product of high quality. Sign Contractor shall be responsible for providing up-to-date drawings, specifications, graphic schedule, etc., to all sub-contractors.
H. Dimensions Written dimensions on drawings shall have precedence over scaled dimensions.
Sign Fabricator shall verify and be responsible for all dimensions and conditions shown by these drawings. Shop details must be approved prior to fabrication.
I. Discrepancies The Client Construction Manager shall be notified by the Sign Fabricator of any discrepancies in the drawings or graphic message schedule, in field dimensions or conditions and/or changes required in construction details.
J. Rights to Design Sign Fabricator may not manufacture, reproduce, or exhibit these designs, or modify them for any other purpose outside of this current contract without written approval of Gensler and Client.
K. Resiliance Best Practices
1. Comply with local green building codes and client green building standards. At a minimum, manufacturers shall provide VOC content and emissions certification to show compliance with limits listed herein. Products with transparency declarations (Health Product Declarations, Declare, JUST labels, C2C certification, and EPDs) will be prioritized.
2. Recyclability: Clearly state the condition of the materials that can be recycled and their proper labeling
a. Refer to https://How2Recycle.org.
3. Comply with manufacturer's End of Life Disposal recommendations
2.08 Warranty
A. Warranties Submit to Client for Owner’s documentation, a 5-year written warranty (effective the date of final acceptance) covering all project signs, graphics and components.
Warranties to be signed by the Sign Fabricator and Installer, agreeing to repair or replace Work which has failed as a result of defects in materials or workmanship or installation. Upon notification of such defects, within the warranty period, make necessary repairs or replacement at the convenience of Client.
B. Linear Polyurethane Paint Factory Finish Warranty Submit to Client Construction Manager for Owner’s documentation. Furnish 5-year written warranty, warranting that the factory-applied linear polyurethane finishes will not develop excessive fading or excessive non uniformity of color or shade, and will not crack, peel, pit, corrode or otherwise fail as a result of defects in materials or workmanship within the following defined limits. Upon notification of such defects, within the warranty period, make necessary repairs or replacement at the convenience of Client.
B.1 “Excessive Fading” A change in appearance which is perceptible and objectionable as determined when visually compared with the original color range standards.
B.2 “Excessive Non-Uniformity” Non-uniform fading to the extent that adjacent panels have a color difference greater than the original acceptable color range.
B.3 “Will Not Pit or Otherwise Corrode” No pitting or other type of corrosion, discernible from a distance of 10 feet (3m), resulting from the natural elements in the atmosphere at the project site.
2.09 Maintenance
A. Maintenance and Operating Cut Sheets Submit 2 copies to Client for Owner’s documentation and 1 copy for Gensler’s documentation. Furnish complete cut sheets describing the materials, devices and procedures to be followed in operating, cleaning and maintaining the Work.
Include manufacturers’ brochures and parts lists describing the actual materials used in the Work, including metal alloys, finishes, electrical components and other major components. Assemble cut sheets for component parts into single folders/packages identified for each system.
PART 3 - PRODUCTS & EXECUTION
3.01 Sign Materials
A. Adhesives Silicone adhesive used for assembling signs, where necessary, shall be manufactured by Dow Corning or equal.
B. All Specified Metals B.1 Aluminum Aluminum shall be suitable for ornamental, architectural work. Surface finish shall be smooth, free of extrusion marks or imperfections. Alloy shall be selected to meet the structural requirements of the specific application.
C. Acrylic Sheet Plastic Use Acrylite® as manufactured by Evonik Cyro LLC, or equal. Thickness shall be as indicated on drawings. Contractor shall provide color and finish samples of all plastics for approval before fabrication; no substitution in color, thickness, or finish of plastics will be accepted without written approval. All plastics shall be of uniform color, translucence and illumination, as supplied by manufacturer. Any exposed edges of acrylic shall be finished so as no tooling marks are visible.
D. Concrete: Not Applicable
E. Fasteners Bolts, nuts, screws, washers, anchors and other devices required to complete the work shall be concealed where possible, except that no hardware shall be visible on sign faces. Same basic metal or alloy as the metal fastened, and finished to match in color and texture. Stainless steel 300 series alloy where used to join dissimilar materials.
F. Welding Electrodes and Filler Metal Provide the alloy and type required for strength, workability, compatibility and color match after grinding smooth and finishing the fabricated product.
3.02 Sign Products
A. Typefaces:
1. As noted in Typography details
3.04 Finishing Materials
A. Linear…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .