20241015_Alliant_to_Ferris_Center_Plans_Final.pdf
PDF 8 MB Posted
- Solicitation number
- 2024-RFB-094-PR
- Issued by
- Dane County, Wisconsin
About this file
This document is a comprehensive set of construction plans and communication schematics for a fiber optic deployment project involving Dane County, Wisconsin, specifically connecting the Alliant Energy Center and Ferris Center. The project involves installing approximately 48-strand fiber optic cables, conduits, handholes, and splice enclosures across multiple locations, with detailed construction plans showing precise routes through buildings and exterior spaces. The plans outline specific installation requirements, including building penetrations, cable routing through mechanical rooms, and splice vault locations, with extensive notes detailing coordination requirements with Dane County staff.
The project involves multiple phases of fiber optic infrastructure deployment, including removing existing fiber infrastructure, installing new armored fiber optic cables, creating new handholes, and terminating fiber connections in network rooms. The communication schematics provide intricate details on fiber strand connections, splice locations, and termination points, with specific instructions for contractors regarding splicing procedures, cable types, and coordination with county personnel. The plans include photographic documentation of proposed installation locations and specific technical requirements for cable routing, building entry points, and network room modifications, suggesting a complex, precisely planned telecommunications infrastructure upgrade.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Alliant_Energy_Center_to_Ferris_Center_Fiber_Loop.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CITY
14 LAKE KEGONSA
D
T
Fitchburg
Middleton
Monona
McFarland
Maple Bluff
Hills Shorewood BLOOMING
GROVE
9 4 5
L.
Wingra
Madison
17 16
MS
BB
BW
MC
PD
AB
MM
258 260
264 265 266 267
138 240
Mud L.
Waubesa L.
Lake Monona
Lake Mendota
TRAIL
CAPITAL
SPRINGS133
Nine Springs
CAPITAL
Title
General Notes and Legend
Estimate of Quantities
Miscellaneous Quantities
Right of Way Plat
Plan and Profile
Standard Detail Drawings
Sign Plates
Structure Plans
Computer Earthwork Data
Cross Sections
ORDER OF SHEETS
LAYOUT
SCALE
CORPORATE LIMITS
PROPERTY LINE
LOT LINE
EXISTING RIGHT OF WAY
SLOPE INTERCEPT
COMBUSTIBLE FLUIDS
POWER POLE
TELEPHONE POLE
ORIGINAL GROUND
MARSH OR ROCK PROFILE
UTILITY PEDESTAL
GAS
ELECTRIC
G
E
T
PROPOSED OR NEW R/W LINE
CAUTION
WOODED OR SHRUB AREA
MARSH AREA
EXISTING CULVERT
PROPOSED CULVERT
(Box or Pipe)
CULVERT (Profile View)
CONVENTIONAL SYMBOLS
ROCK
(To be noted as such)
SS
W
SANSANITARY SEWER
STORM SEWER
WATER
COUNTY:
PLOT NAME : H:\PROJECTS\12000\12598\CAD_BIM\SHEETSPLAN\ALLIANT TO FERRIS\TITLE - GENERAL NOTES - PLAN SHEETS_FINAL.DWGFILE NAME : 9/26/2024 5:08 PMPLOT DATE : PLOT BY : BRENT BOKEMPER
FOFIBER OPTIC
UTILITIESREFERENCE LINE
GRADE LINE
PROFILE
TELEPHONE
SPECIAL DITCH LABELLIMITED HIGHWAY EASEMENT
TOTAL SHEETS = 13
GRADE ELEVATION 95
.3
PLAN
Section No.
Section No.
Section No.
Section No.
Section No.
Section No.
Section No.
Section No.
Section No.
Section No.
Section No.
300'EB'
COORDINATES ON THIS PLAN ARE REFERENCED TO THE WISCONSIN
COUNTY COORDINATE SYSTEM, DANE COUNTY.
PROJECT LOCATION
2.0 MI.
E
DANE
ALLIANT TO FERRIS CENTER
DANE COUNTY
FIBER DEPLOYMENT
WISDOT/CADDS SHEET 42
ECOUNTY: DANE
H:\PROJECTS\12000\12598\CAD_BIM\SHEETSPLAN\ALLIANT TO FERRIS\12598.10_TITLESHEET-GENERALNOTES.DWGFILE NAME : 9/26/2024 4:23 PMPLOT DATE : PLOT BY : BRENT BOKEMPER
PROJECT: ALLIANT TO FERRIS CENTER FIBER DEPLOYMENT
PLOT NAME :
SHEET
PLOT SCALE : 1 IN:100 FT
GENERAL NOTES
LAYOUT NAME - General Notes
DIGGERS HOTLINE
Dial or (800)242-8511 www.DiggersHotline.com
COMMUNICATIONS
DANE COUNTY
SAM OLSON
OLSON@COUNTYOFDANE.COM
608-283-2970
210 MARTIN LUTHER KING JR BLVD
MADISON, WI 53703
SRF CONSULTING GROUP
ALYSSA SEGALL
763-452-4714
ASEGALL@SRFCONSULTING.COM
ERIK MINGE
763-249-6739
EMINGE@SRFCONSULTING.COM
3701 WAYZATA BLVD
MINNEAPOLIS, MN 55416-3791
STANDARD ABBREVIATIONS
EX ----- EXISTING
FO ----- FIBER OPTIC
HH ----- HANDHOLE
LEGEND
DESCRIPTION SYMBOL
HANDHOLE -----------------------------------
CONDUIT -------------------------------------
SPLICE ENCLOSURE ------------------------
RACK ------------------------------------------
GENERAL NOTES
THESE PLANS AND THE ASSOCIATED SPECIAL PROVISIONS REFLECT CONDITIONS KNOWN DURING THE DEVELOPMENT OF THE PLANS AND SPECIAL PROVISIONS. THE CONTRACTOR IS FULLY RESPONSIBLE FOR THE APPLICATION OF ALL WORK SHOWN IN THE PLANS TO THE ACTUAL PHYSICAL FIELD CONDITIONS IN ORDER TO PROVIDE A COMPLETE AND ACCEPTED PROJECT. IN THE EVENT THAT ACTUAL PHYSICAL FIELD CONDITIONS AFFECT OR PREVENT THE APPLICATION OR PROGRESSION OF ANY WORK SHOWN IN THE PLANS OR SPECIAL PROVISIONS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY, PRIOR TO ANY FURTHER
WORK BEING PERFORMED.
ANY CHANGES TO THE WORK SHOWN IN THE PLANS SHALL BE APPROVED IN WRITING BY THE ENGINEER PRIOR TO THE WORK
BEING PERFORMED.
THE LOCATIONS OF EXISTING AND PROPOSED UTILITY INSTALLATIONS SHOWN ON THE PLANS ARE APPROXIMATE. THERE MAY BE
OTHER UTILITY INSTALLATIONS WITHIN THE PROJECT AREA THAT ARE NOT SHOWN.
THE CONTRACTOR SHALL NOTIFY DIGGERS HOTLINE AND AFFECTED UTILITIES PRIOR TO THE START OF WORK. ANY UTILITY WHICH
IS NOT A MEMBER OF THE DIGGERS HOTLINE MUST BE CONTACTED SEPARATELY.
ALL EXISTING UNDERGROUND AND ABOVE GROUND STRUCTURES AND FACILITIES WITHIN THE SCOPE OF THIS PROJECT MAY NOT BE SHOWN IN THE PLANS. THE CONTRACTOR IS FULLY RESPONSIBLE FOR LOCATING ALL UNDERGROUND AND ABOVE GROUND
STRUCTURES AND FACILITIES.
TYPICAL EQUIPMENT FOR THIS WORK INCLUDES A PICKUP TRUCK, MINI EXCAVATOR, CONDUIT PLOW, BORING MACHINE, AND A
FIBER SPLICING TRAILER.
NOTIFY THE ENGINEER (PRIMARY 608-283-2970, SECONDARY 763-452-4714) AT LEAST TWO WEEKS PRIOR TO STAKING ANY
DEVICE LOCATIONS.
NOTIFY THE ENGINEER (PRIMARY 608-283-2970, SECONDARY 763-452-4714) AT LEAST FORTY-EIGHT HOURS PRIOR TO
PENETRATING BUILDINGS.
NOTIFY THE ENGINEER (PRIMARY 608-283-2970, SECONDARY 763-452-4714) AT LEAST FORTY-EIGHT HOURS IN ADVANCE OF ANY WORK ON CITY OF MADISON OWNED OR MAINTAINED FACILITIES TO ARRANGE FOR AN INSPECTOR TO BE PRESENT DURING ALL SUCH WORK. WORK SHALL NOT COMMENCE UNTIL THE CITY TRAFFIC ENGINEERING INSPECTOR IS PRESENT.
HAND DIG TRENCHES NEAR EXISTING CONDUITS AND CABLES. VERIFY DEPTHS OF EXISTING CONDUITS AND CABLES PRIOR TO
CROSSING BY DIRECTIONAL BORE.
ALL CABLE PULLING AND SPLICING OPERATIONS SHALL OCCUR AT ACCESS POINTS (HANDHOLES, COMMUNICATION VAULTS, ETC.)
SHOWN IN THE PLANS.
ALL SPLICING OPERATIONS SHALL OCCUR BETWEEN THE HOURS OF 12:00AM AND 6:00AM.
WETLANDS, WATERWAYS, AND OTHER ENVIRONMENTALLY SENSITIVE AREAS SHALL BE PROTECTED AT ALL TIMES. DO NOT STORE
EQUIPMENT OR MATERIALS NEAR THESE SITES UNLESS APPROVED BY THE ENGINEER.
NO TREES OR SHRUBS ARE TO BE REMOVED WITHOUT APPROVAL OF THE ENGINEER.
AREAS WITHIN THE RIGHT-OF-WAY DISTURBED DUE TO CONSTRUCTION OPERATIONS ARE TO BE RESTORED TO THE ORIGINAL CONDITION WITH TOPSOIL, FERTILIZER, SEED, AND MULCH. NO PAYMENT WILL BE MADE FOR RESTORING AREAS DISTURBED DUE
TO CONSTRUCTION OPERATIONS.
PLOT SCALE : 1 IN:1000 FT
WISDOT/CADDS SHEET 44
ECOUNTY: DANE
H:\PROJECTS\12000\12598\CAD_BIM\SHEETSPLAN\ALLIANT TO FERRIS\12598.10_PO.DWGFILE NAME : 9/26/2024 4:23 PMPLOT DATE : PLOT BY : BRENT BOKEMPER
PROJECT: ALLIANT TO FERRIS CENTER FIBER DEPLOYMENT
PLOT NAME :
SHEET PROJECT OVERVIEW
LAYOUT NAME - Project Overview
PROJECT LOCATION
US 14
S.
P
AR
K
ST
FI
SH
H
AT
CH
ER
Y R D
US 18 US 51
RI
M
RO
CK
R D
JOHN NOLEN DR
I 9
FERRIS CENTER
ALLIANT ENERGY CENTER
ECOUNTY:
H:\PROJECTS\12000\12598\CAD_BIM\SHEETSPLAN\ALLIANT TO FERRIS\12598.10_CP.DWGFILE NAME : 10/15/2024 9:38 AMPLOT DATE : PLOT BY : BRENT BOKEMPER
PROJECT:
PLOT NAME :
SHEET
PLOT SCALE : Custom
ALLIANT TO FERRIS CENTER FIBER DEPLOYMENT DANE CONSTRUCTION PLANS
LAYOUT NAME - 01
EXISTING:
2" CONDUIT
FIBER OPTIC CABLE 24-CT
NO. 10 LOCATE WIRE
REMOVE:
FIBER OPTIC CABLE 24-CT
NO. 10 LOCATE WIRE
FURNISH & INSTALL:
ARMORED FIBER OPTIC CABLE 48-CT
NO. 10 LOCATE WIRE
E RUSK AVE
RI
M
RO
CK
R D
SCALE
0 25FT
M
AT
CH
LI
N E
A
EXISTING:
TYPE V HANDHOLE
FURNISH & INSTALL:
FIBER OPTIC SPLICE ENCLOSURE
FIBER OPTIC SPLICE 48-CT
EXISTING:
TYPE VII HANDHOLE
TYCO 600 SPLICE CASE
FURNISH AND INSTALL:
FIBER OPTIC SPLICE 8-CT
EXISTING:
CONDUIT
FIBER OPTIC CABLE 48-CT
NO. 10 LOCATE WIRE
EXISTING:
CONDUIT
FIBER OPTIC CABLE 48-CT BACKBONE
NO. 10 LOCATE WIRE
EXISTING:
CONDUIT
FIBER OPTIC CABLE 48-CT BACKBONE
NO. 10 LOCATE WIRE
EXHH-1
EXHH-2
H:\PROJECTS\12000\12598\CAD_BIM\SHEETSPLAN\ALLIANT TO FERRIS\12598.10_CP.DWGFILE NAME : 10/3/2024 1:57 PMPLOT DATE : PLOT BY : BRENT BOKEMPER
PROJECT:
PLOT NAME :
SHEET
PLOT SCALE : Custom
ALLIANT TO FERRIS CENTER FIBER DEPLOYMENT DANE CONSTRUCTION PLANS
LAYOUT NAME - 02
EXISTING:
2" CONDUIT
FIBER OPTIC CABLE 24-CT
NO. 10 LOCATE WIRE
REMOVE:
FIBER OPTIC CABLE 24-CT
NO. 10 LOCATE WIRE
FURNISH & INSTALL:
ARMORED FIBER OPTIC CABLE 48-CT
NO. 10 LOCATE WIRE
SEE NOTE 1
FERRIS CENTER
E R
USK
A
VE
SCALE
0 25FT
M
AT
CH
LI
N E
A
MATCHLINE B
EXISTING:
TYPE 1 HANDHOLE
REMOVE:
TYPE 1 HANDHOLE
FURNISH & INSTALL:
TYPE V HANDHOLE
FIBER OPTIC SPLICE ENCLOSURE
FIBER OPTIC SPLICE 16-CT
FURNISH & INSTALL:
2" CONDUIT
ARMORED FIBER OPTIC CABLE 48-CT
NO. 10 LOCATE WIRE
EXISTING:
2" CONDUIT
FIBER OPTIC CABLE 24-CT
NO. 10 LOCATE WIRE
FURNISH & INSTALL:
TYPE 1 HANDHOLE
FURNISH & INSTALL:
2" CONDUIT
ARMORED FIBER OPTIC CABLE 48-CT
NO. 10 LOCATE WIRE
NOTES:
1. CONTRACTOR SHALL CUT THE EXISTING 24CT FIBER AND MAY USE IT TO PULL IN THE NEW
48CT FIBER DURING A SCHEDULED DAYTIME OUTAGE WINDOW.
HH-4
HH-3
H:\PROJECTS\12000\12598\CAD_BIM\SHEETSPLAN\ALLIANT TO FERRIS\12598.10_CP.DWGFILE NAME : 10/3/2024 1:57 PMPLOT DATE : PLOT BY : BRENT BOKEMPER
PROJECT:
PLOT NAME :
SHEET
PLOT SCALE : Custom
ALLIANT TO FERRIS CENTER FIBER DEPLOYMENT DANE CONSTRUCTION PLANS
LAYOUT NAME - 03
FURNISH & INSTALL:
2" CONDUIT
ARMORED FIBER OPTIC CABLE 48-CT
NO. 10 LOCATE WIRE
SCALE
0 25FT
MATCHLINE B
MATCHLINE C
ALLIANT ENERGY CENTER
FERRIS CENTER
FURNISH & INSTALL:
TYPE 1 HANDHOLE
FURNISH & INSTALL:
TYPE 1 HANDHOLE
FURNISH & INSTALL:
2" CONDUIT
ARMORED FIBER OPTIC CABLE 48-CT
NO. 10 LOCATE WIRE
NOTES:
1. CONTRACTOR SHALL INSTALL THE STRUCTURE MOUNTED HAND HOLE NEAR THE TOP OF
THE SE CORNER OF THE BUILDING. COORDINATE HAND HOLE PLACEMENT AND BUILDING
ENTRY POINT WITH DANE COUNTY STAFF. SEE PHOTO 1 ON SHEET 9.
2. CONTRACTOR SHALL SPLICE ARMORED FIBER CABLE TO PLENUM RATED ARMORED CABLE.
INCLUDE 100 FEET OF SLACK LOOPS AT SPLICE LOCATION. SEE COMMUNICATION
SCHEMATICS. SEE PHOTO 2 ON SHEET 9 FOR ENTRY POINT AND SPLICE LOCATION.
3. CONTRACTOR SHALL RUN THE CONDUIT AND CABLE ALONG THE WEST SIDE OF THE
MECHANICAL/STORAGE ROOM BELOW THE STEAM AND WATER PIPES. SEE PHOTO 3 ON
SHEET 9.
HH-6
HH-7
HH-5
FURNISH & INSTALL:
1.5" RIGID STEEL CONDUIT
ARMORED FIBER OPTIC CABLE 48-CT
FURNISH & INSTALL:
STRUCTURE MOUNTED HAND HOLE
SEE NOTE 1
FURNISH & INSTALL:
BUILDING PENETRATION
ARMORED FIBER OPTIC CABLE 48-CT
FURNISH & INSTALL:
ARMORED FIBER OPTIC CABLE 48-CT
SEE NOTE 3
FURNISH & INSTALL:
FIBER OPTIC SPLICE ENCLOSURE
FIBER OPTIC SPLICE 48-CT
SEE NOTE 2
H:\PROJECTS\12000\12598\CAD_BIM\SHEETSPLAN\ALLIANT TO FERRIS\12598.10_CP.DWGFILE NAME : 10/3/2024 1:57 PMPLOT DATE : PLOT BY : BRENT BOKEMPER
PROJECT:
PLOT NAME :
SHEET
PLOT SCALE : Custom
ALLIANT TO FERRIS CENTER FIBER DEPLOYMENT DANE CONSTRUCTION PLANS
LAYOUT NAME - 04
SCALE
0 25FT
MATCHLINE C
NOTES:
1. CONTRACTOR SHALL PUNCH THROUGH THE BALLROOM NEAR THE CENTER OF THE BUILDING.
COORDINATE WITH DANE COUNTY STAFF TO DETERMINE LOCATION AND METHOD OF
PENETRATION.
2. CONTRACTOR SHALL RUN THE CONDUIT WEST ALONG THE CENTER OF THE BALLROOM.
COORDINATE RUN PLACEMENT WITH DANE COUNTY STAFF. SEE PHOTO 4 ON SHEET 9.
3. CONTRACTOR SHALL ENTER MECHANICAL ROOM ON WEST SIDE OF BUILDING THROUGH
EXISTING HOLE IN THE BALLROOM.
4. INSIDE THE NETWORK ROOM, CONTRACTOR SHALL INSTALL 48-CT FIBER THROUGH THE
EXISTING CORE. SEE PHOTO 5 ON SHEET 9.
5. CONTRACTOR SHALL COORDINATE TERMINATION INSIDE THE LOWER LEVEL NETWORK ROOM
WITH DANE COUNTY STAFF. SEE PHOTO 6 ON SHEET 9. SEE COMMUNICATION SCHEMATICS.
6. CONTRACTOR SHALL RUN 12-CT AND 48-CT ARMORED FIBER IN THE SAME CORE AT THIS
LOCATION. SEE PHOTO 5 ON SHEET 9.
7. CONTRACTOR SHALL CONTINUE 12-CT FIBER ROUTE NORTH ALONG CEILING THROUGH
MULTIPLE ROOMS. SEE PHOTO 7 ON SHEET 10.
FURNISH & INSTALL:
ARMORED FIBER OPTIC CABLE 48-CT
SEE NOTE 2
ALLIANT ENERGY CENTER
EXISTING:
RACK (ALLIANT CENTER NETWORK ROOM)
FURNISH AND INSTALL:
FIBER OPTIC TERMINATION/PATCH PANEL (48 POSITION)
FIBER OPTIC TERMINATION/ PATCH PANEL (12 POSITION)
FIBER OPTIC SPLICE 60-CT
FIBER OPTIC TERMINATION 5-CT
BUILDING PENETRATION
SEE NOTE 5
SEE NOTE 3
FURNISH AND INSTALL:
ARMORED FIBER OPTIC CABLE 48-CT
SEE NOTE 4
FURNISH & INSTALL:
BUILDING PENETRATION
SEE NOTE 1
MATCHLINE D
FURNISH & INSTALL:
ARMORED FIBER OPTIC CABLE 12-CT
SEE NOTE 7
SEE NOTE 6
FURNISH & INSTALL:
ARMORED FIBER OPTIC CABLE 12-CT
H:\PROJECTS\12000\12598\CAD_BIM\SHEETSPLAN\ALLIANT TO FERRIS\12598.10_CP.DWGFILE NAME : 10/3/2024 1:57 PMPLOT DATE : PLOT BY : BRENT BOKEMPER
PROJECT:
PLOT NAME :
SHEET
PLOT SCALE : Custom
ALLIANT TO FERRIS CENTER FIBER DEPLOYMENT DANE CONSTRUCTION PLANS
LAYOUT NAME - 05
SCALE
0 25FT
MATCHLINE D
NOTES:
1. CONTRACTOR SHALL CONTINUE 12-CT FIBER RUN NORTH FROM SHEET 7 TO NORTH INTERIOR
WALL IN THE CENTER OFFICE LOCATED ON THE TOP FLOOR OF THE NORTHWEST CORNER OF
ALLIANT ENERGY CENTER. CONTRACTOR SHALL THEN RUN EAST ALONG NORTH WALL BEFORE
SPLICING INTO EXISTING FIBER LOOP. SEE PHOTO 8 ON SHEET 10.
2. CONTRACTOR SHALL MOUNT SPLICE ENCLOSURE TO PLYWOOD PANEL. COORDINATE SPLICING
INSIDE THE ALLIANT CENTER CENTER OFFICE WITH DANE COUNTY STAFF. SEE PHOTO 9 ON
SHEET 10.
3. CONTRACTOR SHALL FIELD VERIFY EXISTING FIBER INSIDE ADMINISTRATION BUILDING IS THE SAME EXISTING FIBER BEING SPLICED IN THE CENTER OFFICE. SEE PHOTO 10 ON SHEET 10.
ALLIANT ENERGY CENTER
ALLIANT ENERGY CENTER
ADMINISTRATION BUILDING
EXISTING:
HANDHOLE
EXISTING:
HANDHOLE
EXISTING:
CONDUIT
FIBER OPTIC CABLE 12-CT
NO. 10 LOCATE WIRE
EXHH-8
EXHH-9
FURNISH AND INSTALL:
ARMORED FIBER OPTIC
CABLE 12-CT
EXISTING:
RIGID METAL CONDUIT
FIBER OPTIC CABLE 12-CT
EXISTING:
RACK (ALLIANT CENTER - CENTER OFFICE)
FURNISH AND INSTALL:
FIBER OPTIC SPLICE ENCLOSURE
FIBER OPTIC SPLICE 12-CT
SEE NOTE 2
SEE NOTE 1
EXISTING:
CONDUIT
FIBER OPTIC CABLE 12-CT
NO. 10 LOCATE WIRE
EXISTING:
RACK
FURNISH AND INSTALL:
FIBER OPTIC TERMINATION/PATCH PANEL (12 POSITION)
FIBER OPTIC SPLICE 12-CT
FIBER OPTIC TERMINATION 1-CT
SEE NOTE 3
H:\PROJECTS\12000\12598\CAD_BIM\SHEETSPLAN\ALLIANT TO FERRIS\12598.10_CP.DWGFILE NAME : 10/3/2024 1:57 PMPLOT DATE : PLOT BY : BRENT BOKEMPER
PROJECT:
PLOT NAME :
SHEET
PLOT SCALE :
ALLIANT TO FERRIS CENTER FIBER DEPLOYMENT DANE CONSTRUCTION PLANS
LAYOUT NAME - 06
PHOTO 1 PHOTO 2 PHOTO 3
PHOTO 4
PHOTO 5
PHOTO 6
RUN FIBER FREELY THROUGH
FLOOR IN CENTER PIPE/SLEEVE
ADD NEW CORING THROUGH
WALL WITH METAL SLEEVE. (3")
H:\PROJECTS\12000\12598\CAD_BIM\SHEETSPLAN\ALLIANT TO FERRIS\12598.10_CP.DWGFILE NAME : 10/3/2024 1:57 PMPLOT DATE : PLOT BY : BRENT BOKEMPER
PROJECT:
PLOT NAME :
SHEET
PLOT SCALE :
ALLIANT TO FERRIS CENTER FIBER DEPLOYMENT DANE CONSTRUCTION PLANS
LAYOUT NAME - 07
PHOTO 7 PHOTO 8
PHOTO 9
PHOTO 10
H:\PROJECTS\12000\12598\CAD_BIM\SHEETSPLAN\ALLIANT TO FERRIS\12598.10_COMMSCHEMATICS.DWGFILE NAME : 10/15/2024 9:42 AMPLOT DATE : PLOT BY : BRENT BOKEMPER
PROJECT: ALLIANT TO FERRIS CENTER FIBER DEPLOYMENT
PLOT NAME :
SHEET
PLOT SCALE : Custom
COMMUNICATION SCHEMATICS
LAYOUT NAME - FO1
NOTES:
1. A SPLICING SYMBOL ON A BUFFER TUBE INDICATES THAT ALL 12 STRANDS SHALL BE
SPLICED.
2. CONTRACTOR SHALL CUT AND RE-SPLICE EXISTING CABLES TO FERRIS CENTER TO NEW
CABLES IN SPLICE VAULT.
3. CONTRACTOR DOES NOT NEED TO COMPLETE ANY WORK INSIDE FERRIS CENTER.
H:\PROJECTS\12000\12598\CAD_BIM\SHEETSPLAN\ALLIANT TO FERRIS\12598.10_COMMSCHEMATICS.DWGFILE NAME : 10/3/2024 1:58 PMPLOT DATE : PLOT BY : BRENT BOKEMPER
PROJECT: ALLIANT TO FERRIS CENTER FIBER DEPLOYMENT
PLOT NAME :
SHEET
PLOT SCALE : Custom
COMMUNICATION SCHEMATICS
LAYOUT NAME - FO2
NOTES:
1. A SPLICING SYMBOL ON A BUFFER TUBE INDICATES THAT ALL 12 STRANDS SHALL BE
SPLICED.
2. CONTRACTOR SHALL SPLICE ARMORED FIBER CABLE TO PLENUM RATED ARMORED CABLE.
3. CONTRACTOR SHALL COORDINATE TERMINATION INSIDE THE LOWER LEVEL NETWORK
ROOM WITH DANE COUNTY STAFF. SEE PHOTO 6 ON SHEET 9.
H:\PROJECTS\12000\12598\CAD_BIM\SHEETSPLAN\ALLIANT TO FERRIS\12598.10_COMMSCHEMATICS.DWGFILE NAME : 10/3/2024 1:58 PMPLOT DATE : PLOT BY : BRENT BOKEMPER
PROJECT: ALLIANT TO FERRIS CENTER FIBER DEPLOYMENT
PLOT NAME :
SHEET
PLOT SCALE : Custom
COMMUNICATION SCHEMATICS
LAYOUT NAME - FO3
NOTES:
1. A SPLICING SYMBOL ON A BUFFER TUBE INDICATES THAT ALL 12 STRANDS SHALL BE
SPLICED.
2. CONTRACTOR SHALL SPLICE THE 12-CT ARMORED FIBER OPTIC CABLE TO EXISTING 12-CT
FIBER LOOP IN THE CENTER OFFICE. SEE PHOTO 9 ON SHEET 10. COORDINATE SPLICING
WITH DANE COUNTY STAFF.
| Sheets and Views |
| 4 12598.10_CP - 01 |
| 5 12598.10_CP - 02 |
| 6 12598.10_CP - 03 |
| 7 12598.10_CP - 04 |
| 8 12598.10_CP - 05 |
| 9 12598.10_CP - 06 |
| 10 12598.10_CP - 07 |
| 11 CommSchematics - FO1 |
| 12 CommSchematics - FO2 |
| 13 12598.10_CommSchematics - FO3 |