This LiDAR Cross Section Conceptual Design document from the Minnesota Department of Natural Resources (DNR) details the existing and proposed channel specifications for the Skandia Wildlife Management Area Stream and Wetland Restoration project in Mower County. The existing channel measurements include a channel/valley length of approximately 2,124 feet with a sinuosity of 1, a channel/floodplain area of 60.9 square feet, and a flood-flow volume of 129,351.6 cubic feet. The proposed channel design specifies a channel length of 3,367 feet, floodplain length of 2,366 feet, increased sinuosity of 1.42, channel/floodplain area of 94 square feet, and an enhanced flood-flow volume of 222,404 cubic feet, representing a 72% increase in flood capacity.

The document outlines road modification options including road abandonment, installation of a new culvert that matches restored channel dimensions and slope, and the addition of floodplain culverts to reduce flood-flow shear. The document notes that all numbers are preliminary based on conceptual design and will require further modeling. The presentation appears to contain 21 slides, with the final slides focusing on the conceptual design summary and road modifications.

Text of this file

LiDAR Cross Section

Conceptual Design Summary

• Existing Channel

• Channel/Valley length = ~2124 feet = 1 Sinuosity

• Channel/Floodplain Area = 60.9ft2

• Flood-Flow Volume = 129,351.6 ft3

• Proposed Channel

• Channel Length = 3,367 feet

• Floodplain Length = 2,366 feet

• Sinuosity = 1.42

• Channel/Floodplain Area = 94 ft2

• Flood-Flow Volume = 222,404 ft3 (72% Increase in Flood Capacity)

*NOTE – preliminary numbers based off conceptual design; actual numbers will need to be modeled*

What to do at the road?

• Abandon Road

• New culvert

• Match restored channel dimensions & slope

• Install floodplain culverts to reduce shear of flood-flows

Slide 1
Slide 2
Slide 3
Slide 4
Slide 5
Slide 6
Slide 7
Slide 8
Slide 9
Slide 10
Slide 11
Slide 12
Slide 13
Slide 14
Slide 15
Slide 16
Slide 17
Slide 18
Slide 19
Slide 20: Conceptual Design Summary
Slide 21: What to do at the road?

Other files

File Type Posted
DNR_EWR_PT_SKANDIA_WMA_STREAM___WETLAND_RESTORE.pdf PDF
2024-XX-XX-SkandiaDesignDRAFT.pdf PDF
ptsamplecontractsandexhibits_7-1-2024_Skandia.docx DOCX document
ptrfpattachments_Skandia.docx DOCX document
Addendum_1.docx DOCX document
2024-10-25_SkandiaRFP_Final.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

File details come from the government source that posted it. Updated .