This LiDAR Cross Section Conceptual Design document from the Minnesota Department of Natural Resources (DNR) details the existing and proposed channel specifications for the Skandia Wildlife Management Area Stream and Wetland Restoration project in Mower County. The existing channel measurements include a channel/valley length of approximately 2,124 feet with a sinuosity of 1, a channel/floodplain area of 60.9 square feet, and a flood-flow volume of 129,351.6 cubic feet. The proposed channel design specifies a channel length of 3,367 feet, floodplain length of 2,366 feet, increased sinuosity of 1.42, channel/floodplain area of 94 square feet, and an enhanced flood-flow volume of 222,404 cubic feet, representing a 72% increase in flood capacity.
The document outlines road modification options including road abandonment, installation of a new culvert that matches restored channel dimensions and slope, and the addition of floodplain culverts to reduce flood-flow shear. The document notes that all numbers are preliminary based on conceptual design and will require further modeling. The presentation appears to contain 21 slides, with the final slides focusing on the conceptual design summary and road modifications.
Text of this file
LiDAR Cross Section
Conceptual Design Summary
• Existing Channel
• Channel/Valley length = ~2124 feet = 1 Sinuosity
• Channel/Floodplain Area = 60.9ft2
• Flood-Flow Volume = 129,351.6 ft3
• Proposed Channel
• Channel Length = 3,367 feet
• Floodplain Length = 2,366 feet
• Sinuosity = 1.42
• Channel/Floodplain Area = 94 ft2
• Flood-Flow Volume = 222,404 ft3 (72% Increase in Flood Capacity)
*NOTE – preliminary numbers based off conceptual design; actual numbers will need to be modeled*
What to do at the road?
• Abandon Road
• New culvert
• Match restored channel dimensions & slope
• Install floodplain culverts to reduce shear of flood-flows
| Slide 1 |
| Slide 2 |
| Slide 3 |
| Slide 4 |
| Slide 5 |
| Slide 6 |
| Slide 7 |
| Slide 8 |
| Slide 9 |
| Slide 10 |
| Slide 11 |
| Slide 12 |
| Slide 13 |
| Slide 14 |
| Slide 15 |
| Slide 16 |
| Slide 17 |
| Slide 18 |
| Slide 19 |
| Slide 20: Conceptual Design Summary |
| Slide 21: What to do at the road? |
Other files
| File | Type | Posted |
|---|---|---|
| DNR_EWR_PT_SKANDIA_WMA_STREAM___WETLAND_RESTORE.pdf | ||
| 2024-XX-XX-SkandiaDesignDRAFT.pdf | ||
| ptsamplecontractsandexhibits_7-1-2024_Skandia.docx | DOCX document | |
| ptrfpattachments_Skandia.docx | DOCX document | |
| Addendum_1.docx | DOCX document | |
| 2024-10-25_SkandiaRFP_Final.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
File details come from the government source that posted it. Updated .