About this file
This document is an Asbestos Inspection Report prepared by Asbestos Inspections, LLC for Horry County Government, specifically addressing a property located at 537 Woodland Drive in Murrells Inlet, South Carolina. The inspection was conducted on April 3, 2023, and the report was prepared on April 20, 2023, in accordance with SCDHEC regulation 61-86.1 and OSHA regulation 29 CFR 1926. The purpose of the inspection was to identify asbestos-containing materials (ACMs) prior to the scheduled demolition of the approximately 1,600 square-foot mobile home, which has sustained significant roof damage.
The inspection revealed one asbestos-containing material: a black built-up roof on the rear roof with 5% chrysotile asbestos, covering approximately 400 square feet. This material is classified as friable and in very poor condition. The report recommends that the asbestos-containing material be removed by a properly licensed asbestos abatement contractor, with required asbestos air monitoring during the abatement process. The report is part of a broader Horry County Government project for demolition of condemned dwellings, and contractors will need to submit an abatement application to SCDHEC at least 10 working days prior to any demolition activities. The laboratory analysis was conducted by Eurofins/CEI Labs using Polarized Light Microscopy (PLM) and Transmission Electron Microscopy (TEM) methods.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ASBESTOS INSPECTION REPORT
537 Woodland Drive
Murrells Inlet, South Carolina Asbestos Inspections, LLC Project # 2023-01-111
Performed in general accordance with SCDHEC regulation 61-86.1 along with OSHA regulation 29 CFR 1926
Assessment Completed by:
Asbestos Inspections, LLC 4686 Pee Dee Highway
Conway, South Carolina 29527
(843) 995-5197
Dawn Schoolcraft
SCDHEC ID# BI-00738
Assessment Completed For:
Mr. Sam LoFaso with Horry County Government 1515 Fourth Avenue
Conway, South Carolina 29526
Inspection Completed On – April 3, 2023 Report Prepared On – April 20, 2023
Asbestos Inspection Report
Project Number – 2023-01-111 April 20, 2023
TABLE OF CONTENTS
1.0 SIGNATURE PAGE
2.0 COVER LETTER
3.0 EXECUTIVE SUMMARY
1.1 Scope and Purpose
2.1 Facility Conditions
3.1 Findings and Conclusions
4.0 ASBESTOS ASSESSMENT DATA
5.0 CONCLUSIONS
Appendix 1- Site Location Plan and Sample Location Plan Appendix 2- Photographs Appendix 3- Laboratory Results Appendix 4- License
1.0 SIGNATURE PAGE
This report has been performed at the request of Mr. Sam LoFaso with Horry County Government. The inspection was conducted by Mr. Mike Schoolcraft with Asbestos Inspections, LLC on April 03, 2023. The report was prepared and reviewed by the undersigned inspector.
Inspection Performed by: SCDEHC# Signature Date
Mike Schoolcraft BI-01624 Mike Schoolcraft April 03, 2023
Report Prepared by:
Dawn Schoolcraft BI-00738 Dawn Schoolcraft April 20, 2023
Report Reviewed by:
Dawn Schoolcraft BI-00738 Dawn Schoolcraft April 20, 2023
2.0 COVER LETTER
Mr. Sam LoFaso with Horry County Government 1515 Fourth Avenue Conway, South Carolina 29526
Subject:
Asbestos Inspection Report 537 Woodland Drive Murrells Inlet, South Carolina 29576 Asbestos Inspections, LLC Project # 2023-01-111
Asbestos Inspections, LLC has completed an Asbestos Assessment and Inspection for the structure located at 537 Woodland Drive, in Murrells Inlet, South Carolina. The inspection was completed on April 03, 2023 by a South Carolina Department of Health and Environmental Control (SCDHEC) building inspector.
The following report summarizes the project background, assessment procedures, results, and conclusions. The results presented in this report are indicative of conditions during the time of the inspection and of the specific areas outlined. The information provided in this report should not be used as a bidding document and field conditions should be verified. Should suspect building materials, not included within this report, be identified or impacted during the destructive activities, bulk samples must be collected and analyzed for asbestos content.
I appreciate this opportunity to provide my services. Should you have any questions concerning this report, please contact me at (843) 995-5197.
Sincerely, Asbestos Building Inspector (SCDHEC #BI-00738)
3.0 EXECUTIVE SUMMARY
1.1 Scope and Purpose
Mr. Sam LoFaso with Horry County Government requested this assessment for the structure located at 537 Woodland Drive in Murrells Inlet, South Carolina. Based on information obtained from you, the structure is scheduled for demolition. The purpose of this assessment was to identify asbestos containing materials (ACMs) prior to demolition.
The inspection was completed in accordance with procedures specified in SCDHEC regulation 61.86.1 along with Occupational Safety and Health Administration (OSHA) regulation 29 Code of the Federal Regulations (CFR) 1926. The representative bulk samples collected were analyzed by a National Voluntary Laboratory Accreditation Program (NVLAP) certified laboratory which is administered by the National Institute of Standards and Technology (NIST). This report has been prepared in accordance with Environmental Protection Agency (EPA) 40 CFR, 763.85(a)(4).
2.1 Facility Conditions
The subject structure is an approximately 1600 square-feet mobile home with a pitched asphalt shingled roof, flat built-up roof on rear, and wood siding. The interior consists of drywall walls and ceilings, carpet, and sheet flooring. The home has sustained major roof damage causing much of the home to be inaccessible
– the floor was very unstable. However, every attempt was made to sample suspect building materials.
Suspect building materials sampled during this inspection include shingles, tarpaper, wall cover, drywall, texture, sheet flooring, and build-up roof.
The possibility exists that suspect materials were undetected in inaccessible areas such as areas deemed unsafe to enter, underneath or behind contents of units, behind exterior veneer, pipe chases, or wall voids. If additional suspect materials not included in this report are discovered during demolition, bulk samples should be collected and analyzed for asbestos content.
3.1 Findings and Conclusions
The EPA and SCDHEC define materials as asbestos containing if an asbestos content >1% is identified in a representative sample. Asbestos >1% was detected in the following suspect materials collected and analyzed:
Material
ID
Material Location Regulatory Result Highest
Analytical Result Est.
Quantity
Black Build-up
Roof
Rear Roof – Very Poor Condition, Friable
Underlying Membrane
Roof
Greater Than 1% Asbestos by Lab (ACM)
5% Chrysotile 400 sq. ft.
The above identified ACM should be removed by a properly licensed asbestos abatement contractor. Asbestos air monitoring will be required during abatement. A copy of this report along with an abatement application should be submitted to SCDHEC at least 10 working days prior to any abatement activities. Additionally, a copy of this report should be provided to the contractors to assist with compliance with applicable State and Federal regulations.
The results presented in this report are indicative of conditions during the time of the assessment. The information provided in this report should not be used as a bidding document and field conditions and quantities should be verified.
4.0 ASBESTOS ASSESSMENT DATA
The assessment was performed by observing and sampling suspect ACMs in the unit prior to the scheduled renovations. Representative bulk samples were then extracted, recorded on a chain of custody, and submitted to Eurofins/CEI Labs of Cary, North Carolina for laboratory analysis. The samples were tested via Polarized Light Microscopy (PLM); however, SCDHEC requires a Transmission Electron Microscopy (TEM) test be performed for all non-friable organically bound material found negative via PLM.
The following tables exhibits the suspect material sampled, location, quantity of material sampled, condition of material, potential for future disturbance, and laboratory analysis.
All Materials Sampled
Id
Material Space Name
Quantity Material Category
Current Condition
Friability Damage Potential
Physical Assessment Category
Shingle/ Tarpaper
Main Roof 1200 sq.
ft.
Miscellaneous
Significantly Damaged
Category I Nonfriable
Potential for
Significant Damage
Wall Cover/
Drywall - Unfinished
Walls Throughout
2500 sq.
ft.
Miscellaneous Significantly
Damaged Friable
(RACM)
Potential for
Significant Damage
Texture/ Drywall
Ceilings Throughout
1600 sq.
ft.
Surfacing Material
Significantly Damaged
Friable
(RACM)
Potential for
Significant Damage
Material Space Name
Quantity Material Category
Current Condition
Friability Damage Potential
Physical Assessment Category
Sheet
Flooring Kitchen and
Laundry 150 sq.
ft.
Miscellaneous
Significantly Damaged
Category I Nonfriable
Potential for
Significant Damage
Built-up Roof –
Underlying Membrane
Roof
Rear Addition / Covered
Porch
400 sq.
ft.
Miscellaneous Significantly
Damaged Category I Nonfriable
Potential for
Significant
Sample Results
Sample # Material % Mineral Type Regulatory Result Analysis Type
001A Black Shingle ND ND Tested Negative by Lab PLM Black Shingle ND ND Tested Negative by Lab PLM
Black Tarpaper ND ND Tested Negative by Lab PLM
001B Black Shingle ND ND Tested Negative by Lab PLM Black Shingle ND ND Tested Negative by Lab PLM
Black Tarpaper ND ND Tested Negative by Lab PLM
001C Black Shingle ND ND Tested Negative by Lab TEM Black Shingle ND ND Tested Negative by Lab TEM
Black Tarpaper ND ND Tested Negative by Lab TEM
002A White Wall Cover ND ND Tested Negative by Lab PLM
White, Brown Drywall ND ND Tested Negative by Lab PLM
002B White Wall Cover ND ND Tested Negative by Lab PLM
White, Brown Drywall ND ND Tested Negative by Lab PLM
002C White Wall Cover ND ND Tested Negative by Lab PLM
White, Brown Drywall ND ND Tested Negative by Lab PLM
003A White Texture ND ND Tested Negative by Lab PLM
White, Brown Drywall ND ND Tested Negative by Lab PLM
003B White Texture ND ND Tested Negative by Lab PLM
White, Brown Drywall ND ND Tested Negative by Lab PLM
003C White Texture ND ND Tested Negative by Lab PLM
White, Brown Drywall ND ND Tested Negative by Lab PLM
003D White Texture ND ND Tested Negative by Lab PLM
White, Brown Drywall ND ND Tested Negative by Lab PLM
003E White Texture ND ND Tested Negative by Lab PLM
White, Brown Drywall ND ND Tested Negative by Lab PLM 004A Off-white Sheet Flooring ND ND Tested Negative by Lab PLM 004B Off-white Sheet Flooring ND ND Tested Negative by Lab PLM 004C Off-white Sheet Flooring ND ND Tested Negative by Lab TEM 005A Black Build-up Roof 5% Chrysotile Greater Than 1% Asbestos by Lab (ACM) PLM 005B Black Build-up Roof -- -- Assumed Positive -- 005C Black Build-up Roof -- -- Assumed Positive --
Please understand that quantities are estimated and should not be used for bidding purposes. Field conditions should be verified prior to bidding.
Site location plan and sample location plan is identified as Figures 1 and 2 in Appendix 1 of this report, photographs are in Appendix 2, laboratory results are in Appendix 3, and license is in Appendix 4.
5.0 CONCLUSIONS
The EPA and SCDHEC define materials as asbestos containing if an asbestos content >1% is detected in a representative sample. Asbestos >1 % was detected in the following suspect materials sampled and analyzed for the structure located at 537 Woodland Drive in Murrells Inlet, South Carolina:
ID
Material Location Regulatory Result Highest
Analytical Result Est.
Quantity
Black Build-up
Roof
Rear Roof – Very Poor Condition, Friable
Underlying Membrane
Greater Than 1% Asbestos by Lab (ACM)
5% Chrysotile 400 sq. ft.
The above identified ACM should be removed by a properly licensed asbestos abatement contractor. Asbestos air monitoring will be required during abatement. A copy of this report along with an abatement application should be submitted to SCDHEC at least 10 working days prior to any abatement activities. Additionally, a copy of this report should be provided to the contractors to assist with compliance with applicable State and Federal regulations.
The possibility exists that suspect materials were undetected in inaccessible areas such as areas deemed unsafe to enter, behind exterior veneer, pipe chases, or wall voids. If additional suspect materials not included in this report are discovered during renovations, bulk samples should be collected and analyzed for asbestos content.
APPENDIX 1
Site Location Plan and Sample Location Plan
Site Location Plan 537 Woodland Dr Murrells Inlet, SC Project # - 2023-01-111
Scale: Not to Scale Reviewed By: DS Date: 4/4/23 Source: N/A
Figure 1
Subject Property
Asbestos Sample Location Plan 537 Woodland Dr Murrells Inlet, SC Project # - 2023-01-111
Figure 2 Scale: Not to Scale Reviewed By: DS Date: 3/10/23 Source: N/A
Figure 2
LEGEND
Sample Location
Asbestos Containing Sample Location
002A
Laundry
Closet
Bath
Covered Porch / Addition
Kitchen Dining Room
Living Room Master
Bedroom Den
Bedroom
Bath
Porch
002C003A
004A-C
003B
002D-E
002B
003C
001A-C
005A-C
Asbestos containing built-up roof - Approx. 400 sq. ft.
APPENDIX 2
Photographs
Site Photos
Exterior Front
Exterior
Kitchen
Bedroom
Interior
Living Room
Exterior Rear Roof
APPENDIX 3
Laboratory Results
April 14, 2023
Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
CLIENT PROJECT: 537 Woodland Dr
CEI LAB CODE: B237417
Dear Customer:
Enclosed are asbestos analysis results for PLM Bulk samples received at our laboratory on April 4, 2023. The samples were analyzed for asbestos using polarizing light microscopy (PLM) per the EPA 600 Method.
Sample results containing >1% asbestos are considered asbestos-containing materials (ACMs) per EPA regulatory requirements. The detection limit for the EPA 600 Method is <1% asbestos by weight as determined by visual estimation.
Thank you for your business and we look forward to continuing good relations.
730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Tianbao Bai, Ph.D., CIH Laboratory Director
Kind Regards, ASBESTOS ANALYTICAL REPORT
By: Polarized Light Microscopy
Prepared for
Asbestos Inspections LLC
CLIENT PROJECT:
LAB CODE:
TEST METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
REPORT DATE:
TOTAL SAMPLES ANALYZED:
# SAMPLES >1% ASBESTOS:
537 Woodland Dr
04/14/23
B237417
730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Asbestos Report Summary By: POLARIZING LIGHT MICROSCOPY
PROJECT: 537 Woodland Dr LAB CODE: B237417
Client ID Lab ID Color Sample Description
ASBESTOS
%Layer
METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
001A Layer 1 B237417.01A Black Shingle None Detected001A
Layer 2 B237417.01A Black Shingle None Detected
B237417.01B Black Tarpaper None Detected
001B Layer 1 B237417.02A Black Shingle None Detected001B
Layer 2 B237417.02A Black Shingle None Detected
B237417.02B Black Tarpaper None Detected
001C Layer 1 B237417.03A Sample Submitted for TEM Analysis
001C
Layer 2 B237417.03A Sample Submitted for TEM Analysis
B237417.03B Sample Submitted for TEM Analysis
002A Layer 1 B237417.04 White Wall Cover None Detected002A
Layer 2 B237417.04 White,Brown Drywall None Detected
002B Layer 1 B237417.05 White Wall Cover None Detected002B
Layer 2 B237417.05 White,Brown Drywall None Detected
002C Layer 1 B237417.06 White Wall Cover None Detected002C
Layer 2 B237417.06 White,Brown Drywall None Detected
003A Layer 1 B237417.07 White Texture None Detected003A
Layer 2 B237417.07 White,Brown Drywall None Detected
003B Layer 1 B237417.08 White Texture None Detected003B
Layer 2 B237417.08 White,Brown Drywall None Detected
003C Layer 1 B237417.09 White Texture None Detected003C
Layer 2 B237417.09 White,Brown Drywall None Detected
003D Layer 1 B237417.10 White Texture None Detected003D
Layer 2 B237417.10 White,Brown Drywall None Detected
003E Layer 1 B237417.11 White Texture None Detected003E
Layer 2 B237417.11 White,Brown Drywall None Detected
004A B237417.12 Off-white Sheet Flooring None Detected004A
004B B237417.13 Off-white Sheet Flooring None Detected004B
004C B237417.14 Sample Submitted for TEM Analysis
004C
Page 1 of 2730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
PROJECT: 537 Woodland Dr LAB CODE: B237417
Client ID Lab ID Color Sample Description
ASBESTOS
%Layer
METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
005A B237417.15 Black Buildup Roof Chrysotile005A 5% 005B B237417.16 Sample Not Analyzed per COC005B
005C B237417.17 Sample Not Analyzed per COC005C
Page 2 of 2730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
ASBESTOS BULK ANALYSIS
Lab Code: B237417 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 537 Woodland Dr
Fibrous
Black 001A
B237417.01A
50%Heterogeneous
Fibrous Bound
40% 10%
Fiberglass Tar Gravel
None Detected Layer 1
Shingle
Black Shingle
B237417.01A 50%Heterogeneous
Fibrous Bound
40% 10%
Fiberglass Tar Gravel
None DetectedLayer 2
Black TarpaperB237417.01B 70%Heterogeneous
Fibrous Bound
30%Cellulose Tar None Detected
Black 001B
B237417.02A
50%Heterogeneous
Fibrous Bound
40% 10%
Fiberglass Tar Gravel
None Detected Layer 1
Shingle
Black Shingle
B237417.02A 50%Heterogeneous
Fibrous Bound
40% 10%
Fiberglass Tar Gravel
None DetectedLayer 2
Black TarpaperB237417.02B 70%Heterogeneous
Fibrous Bound
30%Cellulose Tar None Detected
001C
B237417.03A Layer 1
Sample Submitted for TEM Analysis
Sample Submitted for TEM AnalysisB237417.03A
Layer 2
Sample Submitted for TEM Analysis
B237417.03B
Page 1 of 5730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Lab Code: B237417 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 537 Woodland Dr
Fibrous
White 002A
B237417.04
100%Homogeneous
Fibrous Loosely Bound
Cellulose None Detected Layer 1
Wall Cover
White,Brown Drywall
B237417.04 20% 2%
Heterogeneous
Fibrous Bound
78%Cellulose Fiberglass
Gypsum None DetectedLayer 2
White 002B
B237417.05
100%Homogeneous
Fibrous Loosely Bound
Cellulose None Detected Layer 1
Wall Cover
White,Brown Drywall
B237417.05 20% 2%
Heterogeneous
Fibrous Bound
78%Cellulose Fiberglass
Gypsum None DetectedLayer 2
White 002C
B237417.06
100%Homogeneous
Fibrous Loosely Bound
Cellulose None Detected Layer 1
Wall Cover
White,Brown Drywall
B237417.06 20% 2%
Heterogeneous
Fibrous Bound
78%Cellulose Fiberglass
Gypsum None DetectedLayer 2
White 003A
B237417.07
5%Heterogeneous
Fibrous Bound
80% 10% 5%
Fiberglass Binder Foam Paint
None Detected Layer 1
Texture
Page 2 of 5730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Lab Code: B237417 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 537 Woodland Dr
Fibrous
White,Brown Drywall
B237417.07 20% 2%
Heterogeneous
Fibrous Bound
78%Cellulose Fiberglass
Gypsum None DetectedLayer 2
White 003B
B237417.08
5%Heterogeneous
Fibrous Bound
80% 10% 5%
Fiberglass Binder Foam Paint
None Detected Layer 1
Texture
White,Brown Drywall
B237417.08 20% 2%
Heterogeneous
Fibrous Bound
78%Cellulose Fiberglass
Gypsum None DetectedLayer 2
White 003C
B237417.09
5%Heterogeneous
Fibrous Bound
80% 10% 5%
Fiberglass Binder Foam Paint
None Detected Layer 1
Texture
White,Brown Drywall
B237417.09 20% 2%
Heterogeneous
Fibrous Bound
78%Cellulose Fiberglass
Gypsum None DetectedLayer 2
White 003D
B237417.10
5%Heterogeneous
Fibrous Bound
80% 10% 5%
Fiberglass Binder Foam Paint
None Detected Layer 1
Texture
White,Brown Drywall
B237417.10 20% 2%
Heterogeneous
Fibrous Bound
78%Cellulose Fiberglass
Gypsum None DetectedLayer 2
Page 3 of 5730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Lab Code: B237417 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 537 Woodland Dr
Fibrous
White 003E
B237417.11
5%Heterogeneous
Fibrous Bound
80% 10% 5%
Fiberglass Binder Foam Paint
None Detected Layer 1
Texture
White,Brown Drywall
B237417.11 20% 2%
Heterogeneous
Fibrous Bound
78%Cellulose Fiberglass
Gypsum None DetectedLayer 2
Off-white Sheet Flooring004A
B237417.12 Homogeneous
Non-fibrous Tightly Bound
80% 20%
Vinyl Foam
None Detected
Off-white Sheet Flooring004B
B237417.13 Homogeneous
Non-fibrous Tightly Bound
80% 20%
Vinyl Foam
None Detected
Sample Submitted for TEM Analysis
004C B237417.14
Black Buildup Roof005A
B237417.15 Heterogeneous
Non-fibrous Bound
95% Tar 5% Chrysotile
Sample Not Analyzed per COC
005B B237417.16
Sample Not Analyzed per COC
005C B237417.17
Page 4 of 5730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
LEGEND: Non-Anth = Non-Asbestiform Anthophyllite Non-Trem = Non-Asbestiform Tremolite Calc Carb = Calcium Carbonate
METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
REPORTING LIMIT: <1% by visual estimation
REPORTING LIMIT FOR POINT COUNTS: 0.25% by 400 Points or 0.1% by 1,000 Points
REGULATORY LIMIT: >1% by weight
Due to the limitations of the EPA 600 method, nonfriable organically bound materials (NOBs) such as vinyl floor tiles can be difficult to analyze via polarized light microscopy (PLM). EPA recommends that all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is not covered under NVLAP accreditation. Estimated measurement of uncertainty is available on request.
This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results.
Interpretation of the analytical results is the sole responsibility of the client. Samples were received in acceptable condition unless otherwise noted. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government.
Information provided by customer includes customer sample ID and sample description.
ANALYST: APPROVED BY:
Tianbao Bai, Ph.D., CIH Laboratory Director
Nicholas Moore
April 18, 2023
4686 Peedee Hwy Conway, SC 29527
CLIENT PROJECT: 537 Woodland Dr
LAB CODE: T230877
Dear Customer:
Enclosed are asbestos analysis results for TEM bulk samples received at our laboratory on April 11, 2023. The samples were analyzed for asbestos using transmission electron microscopy (TEM) per Chatfield/EPA 600/R-93/116 Sec. 2.5.5.1 method.
Sample results containing > 1% asbestos are considered asbestos-containing materials (ACMs) per the EPA regulatory requirements. The detection limit for the TEM Chatfield/EPA 600/R-93/116 Sec. 2.5.5.1 method is <1% depending on the processed weight and constituents of the sample.
Thank you for your business and we look forward to continuing good relations.
Tianbao Bai, Ph.D., CIH Laboratory Director
By: Transmission Electron Microscopy
Prepared for
Asbestos Inspections LLC
CLIENT PROJECT:
LAB CODE:
TEST METHOD: Bulk Chatfield EPA 600 / R93 / 116 Sec. 2.5.5.1
REPORT DATE:
537 Woodland Dr
04/18/23
T230877
By: TRANSMISSION ELECTRON MICROSCOPY
Lab Code: T230877 Date Received: 04-11-23 Date Analyzed: 04-18-23 Date Reported: 04-18-23
Client ID Lab ID
Material Description
TEM BULK CHATFIELD / EPA 600 / R93 / 116 Sec. 2.5.5.1
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 537 Woodland Dr
Sample Weight
(g)
Organic Material
Acid Soluble Material
Acid Insoluble Material
Asbestos
T57938 001C Black Shingle 0.341 21.7 52.5 25.8 None
Detected
T57939 001C Black Shingle 0.446 18.4 43.3 38.3 None
Detected
T57940 001C Black Tarpaper 0.623 95 2.6 2.4 None
Detected
T57941 004C Off-white Sheet Flooring 0.248 95.2 2.8 2 None
Detected
LEGEND: None
METHOD: CHATFIELD & EPA/600/R-93/116 Sec. 2.5.5.1
LIMIT OF DETECTION: Varies with the weight and constituents of the sample (<1%)
REGULATORY LIMIT: >1% by weight
This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI (ECEI). ECEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results.
Interpretation of the analytical results is the sole responsibility of the client. Estimated measurement of uncertainty is available on request and in compliance with regulatory requirements. Samples were received in acceptable condition unless otherwise noted.
Information provided by customer includes customer sample ID, location, volume and area as well as date and time of sampling.
ECEI recommends between 0.20 and 0.50 grams of sample material for TEM bulk analysis.
Any weight below 0.10 grams is considered below protocol guidelines.
**Indicates sample weight below 0.05 grams and is considered insufficient for quantitative analysis.
ANALYST: APPROVED BY:
Tianbao Bai, Ph.D., CIH Laboratory Director
Stacy Ulrich
APPENDIX 4
License
12884, 06/30/2023, North Carolina, Dawn
Schoolcraft
1909008, 09/30/2023, South Carolina, Dawn
LBP-R-I162035-2, 03/16/2024, South Carolina, BI-00738, 06/06/2023, South Carolina, Dawn
539 Woodland Drive
Murrells Inlet, South Carolina Asbestos Inspections, LLC Project # 2024-01-172
Inspection Completed On – May 21, 2024 Report Prepared On – May 24, 2024
539 Woodland Dr
Project Number – 2024-01-172 May 24, 2024
1.0 SIGNATURE PAGE
2.0 COVER LETTER
3.0 EXECUTIVE SUMMARY
1.1 Scope and Purpose
2.1 Facility Conditions
3.1 Findings and Conclusions
4.0 ASBESTOS ASSESSMENT DATA
5.0 CONCLUSIONS
inspection was conducted by Mike Schoolcraft with Asbestos Inspections, LLC on May 21, 2024. The report was prepared and reviewed by the undersigned inspector.
Mike Schoolcraft BI-01624 Mike Schoolcraft May 21, 2024
Report Prepared by:
Dawn Schoolcraft BI-00738 Dawn Schoolcraft May 24, 2024
Dawn Schoolcraft BI-00738 Dawn Schoolcraft May 24, 2024
Mr. Sam LoFaso with Horry County Government 1515 Fourth Avenue Conway, South Carolina 29526
Subject:
Asbestos Inspection Report 539 Woodland Drive Murrells Inlet, South Carolina 29576 Asbestos Inspections, LLC Project # 2024-01-172
Asbestos Inspections, LLC has completed an Asbestos Assessment and Inspection for the structure located at 539 Woodland Drive, in Murrells Inlet, South Carolina. The inspection was completed on May 21, 2024 by a South Carolina Department of Health and Environmental Control (SCDHEC) building inspector.
The following report summarizes the project background, assessment procedures, results, and conclusions. The results presented in this report are indicative of conditions during the time of the inspection and of the specific areas outlined. The information provided in this report should not be used as a bidding document and field conditions should be verified. Should suspect building materials, not included within this report, be identified or impacted during the destructive activities, bulk samples must be collected and analyzed for asbestos content.
I appreciate this opportunity to provide my services. Should you have any questions concerning this report, Mr. Sam LoFaso with Horry County Government requested this assessment for the structure located at 539 Woodland Drive in Murrells Inlet, South Carolina. Based on information obtained from you, the structure is scheduled for demolition. The purpose of this assessment was to identify asbestos containing materials (ACMs) prior to demolition.
The inspection was completed in accordance with procedures specified in SCDHEC regulation 61.86.1 along with Occupational Safety and Health Administration (OSHA) regulation 29 Code of the Federal Regulations (CFR) 1926. The representative bulk samples collected were analyzed by a National Voluntary Laboratory Accreditation Program (NVLAP) certified laboratory which is administered by the National Institute of
The subject structure is a 768 square feet mobile home with a metal roof, metal siding, and metal windows.
The interior consists of wood panelled walls and ceilings, and vinyl sheet flooring. Suspect materials sampled during this inspection include ceiling panel, sheet flooring, and mastic. It appears that renovations began, but were not completed.
The possibility exists that suspect materials were undetected in inaccessible areas such as areas deemed unsafe to enter, underneath or behind contents of units, behind exterior veneer, pipe chases, or wall voids. If additional suspect materials not included in this report are discovered during demolition, bulk samples
The EPA and SCDHEC define materials as asbestos containing if an asbestos content >1% is identified in a representative sample. No asbestos >1% was detected in the suspect materials collected and analyzed:
Material ID Material Regulatory Result Highest Analytical Result Est. Quantity There are no homogenous materials for this project that have tested positive containing asbestos
A copy of this report along with a demolition application should be submitted to SCDHEC at least 10 working days prior to any demolition activities. Additionally, a copy of this report should be provided to the contractors to assist with compliance with applicable State and Federal regulations.
The results presented in this report are indicative of conditions during the time of the assessment. The information provided in this report should not be used as a bidding document and field conditions and
The assessment was performed by observing and sampling suspect ACMs in the unit prior to the scheduled renovations. Representative bulk samples were then extracted, recorded on a chain of custody, and submitted to Eurofins/CEI Labs of Cary, North Carolina for laboratory analysis. The samples were tested via Polarized Light Microscopy (PLM); however, SCDHEC requires a Transmission Electron Microscopy (TEM) test be performed for all non-friable organically bound material found negative via PLM.
The following tables exhibits the suspect material sampled, location, quantity of material sampled, condition
Material Space Name
Quantity Material Category
Current Condition
Friability Damage Potential
Physical Assessment Category
001 Ceiling Panel Ceilings
Throughout 800 sq. ft.
Surfacing Material
Good (No Damage)
Friable
(RACM)
Potential for
Significant Damage
Beige, Tan Sheet
Floor/Off- White Mastic
Rooms 3-7 470 sq. ft. Miscellaneous Good (No Damage)
Category I Nonfriable
Potential for
Significant Damage
Beige Sheet Floor/Cream
Mastic Bathroom 30 sq. ft. Miscellaneous
Good (No Damage)
Category I Nonfriable
Potential for
Significant
001A Tan, Off-white Ceiling Panel ND ND Tested Negative by Lab PLM 001B Tan, Off-white Ceiling Panel ND ND Tested Negative by Lab PLM 001C Tan, Off-white Ceiling Panel ND ND Tested Negative by Lab PLM
002A Beige, Tan Sheet Flooring ND ND Tested Negative by Lab PLM Off-white, Cream Mastic ND ND Tested Negative by Lab PLM
002B Beige, Tan Sheet Flooring ND ND Tested Negative by Lab PLM Off-white, Cream Mastic ND ND Tested Negative by Lab PLM
002C Beige, Tan Sheet Flooring ND ND Tested Negative by Lab TEM Off-white, Cream Mastic ND ND Tested Negative by Lab TEM
003A Beige, Off-white Sheet Flooring ND ND Tested Negative by Lab PLM
Yellow, Cream Mastic ND ND Tested Negative by Lab PLM Brown, Gray Sheet Flooring ND ND Tested Negative by Lab PLM
Off-white, Cream Mastic ND ND Tested Negative by Lab PLM
003B
Beige, Off-white Sheet Flooring ND ND Tested Negative by Lab PLM Yellow, Cream Mastic ND ND Tested Negative by Lab PLM
Brown, Gray Sheet Flooring ND ND Tested Negative by Lab PLM Off-white, Cream Mastic ND ND Tested Negative by Lab PLM
003C
Beige, Off-white Sheet Flooring ND ND Tested Negative by Lab TEM Yellow, Cream Mastic ND ND Tested Negative by Lab TEM
Brown, Gray Sheet Flooring ND ND Tested Negative by Lab TEM Off-white, Cream Mastic ND ND Tested Negative by Lab TEM
Site location plan and sample location plan is identified as Figures 1 and 2 in Appendix 1 of this report, The EPA and SCDHEC define materials as asbestos containing if an asbestos content >1% is detected in a representative sample. No asbestos >1 % was detected in the suspect materials sampled and analyzed for the structure located at 539 Woodland Drive in Murrells Inlet, South Carolina:
working days prior to any demolition activities. Additionally, a copy of this report should be provided to the contractors to assist with compliance with applicable State and Federal regulations.
The possibility exists that suspect materials were undetected in inaccessible areas such as areas deemed unsafe to enter, behind exterior veneer, pipe chases, or wall voids. If additional suspect materials not included in this report are discovered during renovations, bulk samples should be collected and analyzed for
Murrells Inlet, SC Project # - 2024-01-172
Scale: Not to Scale Reviewed By: DS Date: 5/22/24 Source: N/A
Murrells Inlet, SC Project # - 2024-01-172
Scale: Not to Scale Reviewed By: DS Date: 5/22/24 Source: N/A
Figure 2
LEGEND
Sample Location
Asbestos Containing Sample Location
Porch
003A-C
Bedroom
Bath
Kitchen/Living Room
Laundry 5
Bedroom
Bath
Bedroom
002A-C 001B
001C
001A
Living Room/Kitchen
Laundry
Bathroom
May 23, 2024
4686 Peedee Hwy Conway, SC 29527
CLIENT PROJECT: 539 Woodland Dr.
CEI LAB CODE: B249982
Dear Customer:
Enclosed are asbestos analysis results for PLM Bulk samples received at our laboratory on May 22, 2024. The samples were analyzed for asbestos using polarizing light microscopy (PLM) per the EPA 600 Method.
Sample results containing >1% asbestos are considered asbestos-containing materials (ACMs) per EPA regulatory requirements. The detection limit for the EPA 600 Method is <1% asbestos by weight as determined by visual estimation.
Thank you for your business and we look forward to continuing good relations.
730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Tianbao Bai, Ph.D., CIH
Prepared for
Asbestos Inspections LLC
CLIENT PROJECT:
LAB CODE:
TEST METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
REPORT DATE:
TOTAL SAMPLES ANALYZED:
# SAMPLES >1% ASBESTOS:
539 Woodland Dr.
05/23/24
B249982
PROJECT: 539 Woodland Dr. LAB CODE: B249982
Client ID Lab ID Color Sample Description
ASBESTOS
%Layer
METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
001A B249982.01 Tan,Off-white Ceiling Panel None Detected001A
001B B249982.02 Tan,Off-white Ceiling Panel None Detected001B
001C B249982.03 Tan,Off-white Ceiling Panel None Detected001C
002A B249982.04A Beige,Tan Sheet Flooring None Detected002A
B249982.04B Off-white, Cream
Mastic None Detected
002B B249982.05A Beige,Tan Sheet Flooring None Detected002B
B249982.05B Off-white, Cream
Mastic None Detected
002C B249982.06A Sample Submitted for TEM Analysis
002C
B249982.06B Sample Submitted for TEM Analysis
003A B249982.07A Beige,Off-white Sheet Flooring None Detected003A
B249982.07B Yellow,Cream Mastic None Detected
B249982.07C Brown,Gray Sheet Flooring None Detected
B249982.07D Off-white, Cream
Mastic None Detected
003B B249982.08A Beige,Off-white Sheet Flooring None Detected003B
B249982.08B Yellow,Cream Mastic None Detected
B249982.08C Brown,Gray Sheet Flooring None Detected
B249982.08D Off-white, Cream
Mastic None Detected
003C B249982.09A Sample Submitted for TEM Analysis
003C
B249982.09B Sample Submitted for TEM Analysis
B249982.09C Sample Submitted for TEM Analysis
B249982.09D Sample Submitted for TEM Analysis
Page 1 of 1730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Lab Code: B249982 Date Received: 05-22-24 Date Analyzed: 05-23-24 Date Reported: 05-23-24
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 539 Woodland Dr.
Fibrous
Tan,Off-white Ceiling Panel001A
B249982.01 95%Heterogeneous
Fibrous Bound
5%Cellulose Paint None Detected
Tan,Off-white Ceiling Panel001B
B249982.02 95%Heterogeneous
Fibrous Bound
5%Cellulose Paint None Detected
Tan,Off-white Ceiling Panel001C
B249982.03 95%Heterogeneous
Fibrous Bound
5%Cellulose Paint None Detected
Beige,Tan Sheet Flooring002A
B249982.04A 15% 35%
Heterogeneous
Fibrous Tightly Bound
50%Cellulose Synthetic Fiber
Vinyl None Detected
Off-white,Cream MasticB249982.04B 3%
2% Homogeneous
Non-fibrous Bound
95%Cellulose Synthetic Fiber
Mastic None Detected
Beige,Tan Sheet Flooring002B
B249982.05A 15% 35%
Heterogeneous
Fibrous Tightly Bound
50%Cellulose Synthetic Fiber
Vinyl None Detected
Off-white,Cream MasticB249982.05B 3%
2% Homogeneous
Non-fibrous Bound
95%Cellulose Synthetic Fiber
Mastic None Detected
Sample Submitted for TEM Analysis
002C B249982.06A
Page 1 of 4730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Lab Code: B249982 Date Received: 05-22-24 Date Analyzed: 05-23-24 Date Reported: 05-23-24
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 539 Woodland Dr.
Fibrous
Sample Submitted for TEM Analysis
B249982.06B
Beige,Off-white Sheet Flooring003A
B249982.07A 35% 15%
Heterogeneous
Fibrous Tightly Bound
50%Cellulose Fiberglass
Vinyl None Detected
Yellow,Cream MasticB249982.07B 3%
2% Homogeneous
Non-fibrous Bound
95%Cellulose Synthetic Fiber
Mastic None Detected
Brown,Gray Sheet FlooringB249982.07C 35%
15% Heterogeneous
Fibrous Tightly Bound
50%Cellulose Fiberglass
Vinyl None Detected
Off-white,Cream MasticB249982.07D 3%
2% Homogeneous
Non-fibrous Bound
95%Cellulose Fiberglass
Mastic None Detected
Beige,Off-white Sheet Flooring003B
B249982.08A 35% 15%
Heterogeneous
Fibrous Tightly Bound
50%Cellulose Fiberglass
Vinyl None Detected
Yellow,Cream MasticB249982.08B 3%
2% Homogeneous
Non-fibrous Bound
95%Cellulose Synthetic Fiber
Mastic None Detected
Brown,Gray Sheet FlooringB249982.08C 35%
15% Heterogeneous
Fibrous Tightly Bound
50%Cellulose Fiberglass
Vinyl None Detected
Page 2 of 4730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Lab Code: B249982 Date Received: 05-22-24 Date Analyzed: 05-23-24 Date Reported: 05-23-24
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 539 Woodland Dr.
Fibrous
Off-white,Cream MasticB249982.08D 3%
2% Homogeneous
Non-fibrous Bound
95%Cellulose Fiberglass
Mastic None Detected
Sample Submitted for TEM Analysis
003C B249982.09A
Sample Submitted for TEM Analysis
B249982.09B
Sample Submitted for TEM Analysis
B249982.09C
Sample Submitted for TEM Analysis
B249982.09D
Page 3 of 4730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Calc Carb = Calcium Carbonate
METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
REPORTING LIMIT: <1% by visual estimation
REPORTING LIMIT FOR POINT COUNTS: 0.25% by 400 Points or 0.1% by 1,000 Points
REGULATORY LIMIT: >1% by weight
Due to the limitations of the EPA 600 method, nonfriable organically bound materials (NOBs) such as vinyl floor tiles can be difficult to analyze via polarized light microscopy (PLM). EPA recommends that all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is not covered under NVLAP accreditation. Estimated measurement of uncertainty is available on request.
This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results.
Interpretation of the analytical results is the sole responsibility of the client. Samples were received in acceptable condition unless otherwise noted. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government.
Information provided by customer includes customer sample ID and sample description.
ANALYST: APPROVED BY:
Tianbao Bai, Ph.D., CIH Laboratory Director
Santi Nicolella
4686 Peedee Hwy Conway, SC 29527
CLIENT PROJECT: 539 Woodland Dr.
LAB CODE: T240831
Dear Customer:
Enclosed are asbestos analysis results for TEM bulk samples received at our laboratory on May 23, 2024. The samples were analyzed for asbestos using transmission electron microscopy (TEM) per Chatfield/EPA 600/R-93/116 Sec. 2.5.5.1 method.
Sample results containing > 1% asbestos are considered asbestos-containing materials (ACMs) per the EPA regulatory requirements. The detection limit for the TEM Chatfield/EPA 600/R-93/116 Sec. 2.5.5.1 method is <1% depending on the processed weight and constituents of the sample.
Thank you for your business and we look forward to continuing good relations.
Tianbao Bai, Ph.D., CIH Laboratory Director
Prepared for
Asbestos Inspections LLC
CLIENT PROJECT:
LAB CODE:
TEST METHOD: Bulk Chatfield EPA 600 / R93 / 116 Sec. 2.5.5.1
REPORT DATE:
539 Woodland Dr.
05/24/24
T240831
Lab Code: T240831 Date Received: 05-23-24 Date Analyzed: 05-24-24 Date Reported: 05-24-24
Client ID Lab ID
Material Description
TEM BULK CHATFIELD / EPA 600 / R93 / 116 Sec. 2.5.5.1
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 539 Woodland Dr.
Sample Weight
(g)
Organic Material
Acid Soluble Material
Acid Insoluble Material
Asbestos
T73359 002C Beige, Tan Sheet Flooring 0.163 85.3 14.1 .6 None
Detected
T73360 002C Off-White, Cream Mastic 0.118 18.6 10.2 71.2 None
Detected
T73361 003C Beige, Off-White Sheet
Flooring
0.246 57.7 17.1 25.2 None
Detected
T73362 003C Yellow, Cream Mastic 0.061 50.8 11.5 37.7 None
Detected
T73363 003C Brown, Gray Sheet
Flooring
0.151 86.8 11.9 1.3 None
Detected
T73364 003C Off-White, Cream Mastic 0.064 39.1 12.5 48.4 None
Detected
LEGEND: None
METHOD: CHATFIELD & EPA/600/R-93/116 Sec. 2.5.5.1
LIMIT OF DETECTION: Varies with the weight and constituents of the sample (<1%)
REGULATORY LIMIT: >1% by weight
This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI (ECEI). ECEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results.
Interpretation of the analytical results is the sole responsibility of the client. Estimated measurement of uncertainty is available on request and in compliance with regulatory requirements. Samples were received in acceptable condition unless otherwise noted.
Information provided by customer includes customer sample ID, location, volume and area as well as date and time of sampling.
ECEI recommends between 0.20 and 0.50 grams of sample material for TEM bulk analysis.
Any weight below 0.10 grams is considered below protocol guidelines.
**Indicates sample weight below 0.05 grams and is considered insufficient for quantitative analysis.
ANALYST: APPROVED BY:
Tianbao Bai, Ph.D., CIH Laboratory Director
Partima Poudel Acharya
APPENDIX 4
License
12884, 06/30/2024, North Carolina, Dawn
1909008, 09/30/2025, South Carolina, Dawn
LBP-R-I162035-3, 03/16/2027, South Carolina, BI-00738, 06/05/2024, South Carolina, Dawn
LEAD-BASED PAINT INSPECTION REPORT
539 Woodland Drive
Murrells Inlet, South Carolina Asbestos Inspections, LLC Project # 2024-01-172
Performed in general accordance with HUD, EPA, SCDHEC, along with OSHA regulation 29 CFR 1926.62
Lead Paint Inspector #LBP-R-I162035-3
Inspection Completed On – May 21, 2024 Report Prepared On – May 28, 2024
Lead-Based Paint Inspection Report
May 28, 2024
1.0 SIGNATURE PAGE
2.0 COVER LETTER
3.0 PROJECT INFORMATION
1.1 Scope and Purpose
2.1 Facility Conditions
3.1 Lead-Based Paint Assessment Data
4.1 Conclusions
Appendix 1-Site Location Plan and Sample Location Plan Appendix 2-Photographs Appendix 3-Lead-Based Paint Laboratory Results Appendix 4-License
This report has been performed at the request of Mr. Sam LoFaso with Horry County Government. The inspection was conducted by Mike Schoolcraft with Asbestos Inspections, LLC on May 21, 2024. The report was prepared and reviewed by the undersigned inspector.
Inspection Performed by: License# Signature Date
Mike Schoolcraft LBP-I-I241150-1 Mike Schoolcraft May 21, 2024
Report Prepared by:
Dawn Schoolcraft LBP-R-I162035-3 Dawn Schoolcraft May 28, 2024
Dawn Schoolcraft LBP-R-I162035-3 Dawn Schoolcraft May 28, 2024
May 28, 2024
Mr. Sam LoFaso with Horry County Government 1515 Fourth Avenue Conway, South Carolina 29526
Subject: Lead-Based Paint Inspection Report 539 Woodland Drive Murrells Inlet, South Carolina 29576 Asbestos Inspections, LLC Project # 2024-01-172
Asbestos Inspections, LLC has completed a Lead-Based Paint Inspection for the structure located at 539 Woodland Drive, in Murrells Inlet, South Carolina. The inspection was completed on May 21, 2024 by a licensed lead paint inspector.
The following report summarizes the project background, assessment procedures, results, and conclusions. The results presented in this report are indicative of conditions during the time of the inspection and of the specific areas outlined. The information provided in this report should not be used as a bidding document and field conditions should be verified. Should suspect paint coated surfaces, not included within this report, be identified or impacted during the destructive activities, samples must be collected and analyzed for lead content.
Disclosure Responsibility: A copy of this summary must be provided to new lessees (tenants), owners and purchasers of this property under Federal Law (24 CFR part 35 and 40 CFR part 745) before they become obligated under a lease or sales contract. The complete report must also be provided to new purchasers and it must be made available to new tenants. Landlords (lessors) and sellers are also required to distribute an educational pamphlet and include standard warning language in their leases or sales contracts to ensure that parents have the information they need to protect their children from lead-based paint hazards.
I appreciate this opportunity to provide my services. Should you have any questions concerning this report, Lead Paint Inspector (License #LBP-R-I162035-3)
3.0 PROJECT INFORMATION
Mr. Sam LoFaso with Horry County Government requested this inspection for the structure located at 539 Woodland Drive, in Murrells Inlet, South Carolina. Based on information obtained from you, the structure is scheduled for demolition. The purpose of this assessment was to identify lead-based paint on building components prior to the scheduled demolition.
The inspection was completed in accordance with procedures specified in the Department of Housing and Urban Development (HUD) 1997 Revision that replaces Chapter 7 Lead-Based Paint Inspection, Environmental Protection Agency (EPA), along with Occupational Safety and Health Administration (OSHA) Lead in Construction Standard regulation 29 Code of the Federal Regulations (CFR) 1926.62. The representative bulk samples collected were analyzed by a laboratory recognized under the Environmental Protection Agencies (EPA) National Lead Laboratory Accreditation Program (NLLAP).
The subject structure is a 768 square feet mobile home with a metal roof, metal siding, and metal windows.
The interior consists of wood panelled walls and ceilings, and vinyl sheet flooring.
The possibility exists that paint coated surfaces were undetected in inaccessible areas such as, locked rooms, behind exterior veneer, pipe chases, or wall voids. If additional suspect paint coated surfaces not included in this report are discovered during renovation, samples should be collected and analyzed for lead content.
3.1 Lead-Based Paint Assessment Data
The assessment was performed by identifying paint coated surfaces associated with the structure in accordance with HUD and EPA guidelines. One paint chip sample was collected for each painted surface of the structure’s building components, which includes but is not limited to shutters, siding, exterior trim, window trim, windowsills, interior and exterior doors, door frames, walls, baseboards, chair rails and floors. The samples collected were approximately 1-4 square inches in size and included all layers of paint, placed inside an appropriate sample container, and labeled accordingly using a unique identification number. A chain of custody was completed for the samples with project specific information and then submitted to Eurofins/CEI for analysis. The samples collected were analyzed via EPA Method SW846 3050B/7000B. The following outlines the paint chip samples collected and analyzed:
Sample # Substrate Component Color Paint Location Condition Lead Concentration
(% by weight) P1 Wood Wall Beige Living Room 1 Intact 0.029 P2 Wood Wall Beige Laundry 5 Intact <0.0045 P3 Wood Wall Beige Bedroom 7 Intact <0.0073
Sample # Substrate Component Color Paint Location Condition Lead Concentration
(% by weight) P4 Wood Cabinet Beige Bedroom 3 Intact <0.0053 P5 Wood Door White Living Room 1 Intact <0.0039
Condition Assessment Key
Type of Bldg. Component Total Area of Deteriorated Paint on Each Component
Intact Fair1 Poor2
Exterior components with large surface area
Entire surface area is intact
Less than or equal to 10 square feet
More than 10 square feet
Interior components with large surface area
Entire surface area is intact
Less than or equal to 2 square feet
More than 2 square feet
Interior and exterior components with small surface areas
Entire surface area is intact
Less than or equal to 10% of the total surface area of component
More than 10% of the total surface area or the component
Superscript 1 = surfaces in “fair” condition should be repaired and/or monitored but are not considered to be lead based paint hazards.
Superscript 2 = surfaces in “poor” condition are considered to be lead based paint hazards as defined by Title X and should be addressed through abatement or interim controls.
Site location plan and sample locations are identified as Figures 1 and 2 in Appendix 1 of this report, photographs are in Appendix 2, lead-based paint lab results are in Appendix 3, and licenses are in Appendix 4.
4.1 Conclusions
HUD and EPA defines paint as lead-based if an amount greater than 1.0 mg/cm2 or 0.5 percent by weight is identified in a paint chip sample and SCDHEC defines lead paint as greater than 0.7 mg/cm2. The results of this inspection indicate that no lead in concentrations greater than or equal to 1.0 mg/cm2, 0.7 mg/cm2, or
0.5 percent by weight was identified on the building components sampled and analyzed for the structure located at 539 Woodland Drive, in Murrells Inlet, South Carolina.
A copy of this report should be provided to the contractors to assist with compliance with applicable State and Federal regulations. Additionally, this report should be kept by the owner and future owners for the life of the dwelling.
Murrells Inlet, SC Project # - 2024-01-172
Scale: Not to Scale Reviewed By: DS Date: 5/22/24 Source: N/A
Sample Location Plan
Murrells Inlet, SC Project # - 2024-01-172
Scale: Not to Scale Reviewed By: DS Date: 5/22/24 Source: N/A
Figure 2
LEGEND
Sample Location
Porch
Bedroom
Bath
Kitchen/Living Room
Laundry 5
Bedroom
Bath
Bedroom
P4 P5
P2
P3
P1
Living Room/Kitchen
Laundry
Bathroom
4686 Peedee Hwy Conway, SC 29527
05-22-24 05-23-24Analyzed:
LABORATORY REPORT
LEAD IN PAINT
Lab Code: L240521
LAB ID
Received:
CLIENT ID
539 Woodland DrProject:
Client:
PPM (µg/g) CONCENTRATION
% BY WEIGHT
Eurofins CEI 730 SE Maynard Road Cary, NC 27511
TEL: 866-481-1412
TEL: 919-481-1413
FAX: 919-481-1442
METHOD: EPA SW846 7000B
05-24-24Reported:
P1 L3258 0.029290
P2 L3259 <0.0045<45
P3 L3260 <0.0073<73
P4 L3261 <0.0053<53
P5 L3262 <0.0039<39
Page 1730 SE Maynard Road • Cary, NC 27511 • 919.481.1413