2022HM_Proposal.Part 1.pdf
PDF 1 MB Posted
- Solicitation number
- RFP - 591 - 220000001996
- Issued by
- Cass County, Casnovia Village, Michigan
About this file
This document is a Special Provision related to a state and local contract opportunity for a Hot Mix Asphalt (HMA) skip paving project on US-12 in Cass County, Michigan. The project requires maintaining traffic throughout construction in accordance with the standard specifications, typicals, and supplemental specifications provided. Key details include a final completion date of July 1, 2022, assessment of liquidated damages for missed interim and final completion dates, and requirements for an approved Internal Traffic Control Plan prior to commencing work. Work is restricted during certain holiday periods, and a minimum of one lane in alternating direction must be maintained at all times.
The document outlines requirements for traffic control devices, temporary pavement markings, and HMA resurfacing. Payment for labor and materials will be considered lump sum for Maintaining Traffic, with no additional payment for certain activities. The project is under the jurisdiction of the Michigan Department of Transportation, Cass County, and the villages of Casnovia.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 2022HM_US-12 Paving_RFP FINAL.docx | DOCX document | |
| Proposal.Part 2.pdf | ||
| Proposal Part 3.pdf | ||
| Proposal Part 4.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROGRESS CLAUSE: Submit a Progress Schedule. The Engineer for this project is as follows:
Dharmesh Valsadia, P.E.
MDOT/Kalamazoo TSC 5372 South 9th St.
Kalamazoo, MI 49009 valsadiaD@michigan.gov
After award, start work on the date approved by the Engineer, which must be no earlier than May 1st, 2022. In no case may any work be commenced prior to award by the Department.
No work will be allowed on Sundays.
The entire project must be completed by the final completion date of July 1st, 2022.
Failure by the Contractor to meet interim completion, open to traffic, and/or final completion dates will result in the assessment of liquidated damages in accordance with subsections 108.10.C.1 and 108.10.C.2 of the Standard Specifications for Construction Liquidated damages will be assessed separately and simultaneously for failure to meet interim completion, open to traffic, and/or final completion dates. Liquidated damages will continue to be assessed for each calendar day that the work associated with the interim completion, open to traffic, and/or final completion dates remains incomplete, even if these days extend into or beyond seasonal suspension, unless approved otherwise by the Engineer.
Unless specific pay items are provided in the contract any extra costs incurred by the Contractor due to cold-weather protection and winter grading will not be paid for separately but will be included in the payment of other pay items in the contract.
After award and prior to the start of work, the Contractor must attend a preconstruction meeting with the Engineer. The Engineer will determine the day, time and place for the preconstruction meeting. The meeting will be conducted after project award and may be rescheduled if there are delays in the award of the project. The named subcontractor(s) for, Designated and/or Specialty Items, as shown in the proposal, is(are) recommended to be at the preconstruction meeting if such items materially affect the work schedule.
The Contractor may be required to meet with Department representatives for a post-construction review meeting, as directed by the Engineer. The Engineer will schedule the meeting.
V3.3
MICHIGAN
DEPARTMENT OF TRANSPORTATION
SPECIAL PROVISION
FOR
MAINTAINING TRAFFIC
KZO:BCB 1 of 5 APPR:KZO:AJ:04/11/22
a. Description. This special provision consists of requirements and restrictions to maintain traffic on US-12 in Ontwa and Porter Townships, Cass County.
b. General. Maintain traffic throughout the project in accordance with the standard specifications, typicals, and supplemental specifications in the contract and as described on the plans for this project.
c. Construction Influence Area (CIA). The CIA includes the right-of-way of the following roadways, within the approximate limits described below:
1. On US-12 from approximately from Eagle Cove easterly to Mason Street.
2. In addition, the CIA includes the right-of-way of any designated detour route or alternate route, intersecting roads adjacent to the work zone for a distance of approximately 350 feet in advance of the work zone.
d. Traffic Restrictions. Maintain traffic in accordance with the Maintaining Traffic Typicals contained herein, except as noted below. Changes or adjustments to the Maintaining Traffic Typicals may be necessary to fit field conditions, subject to approval of the Engineer or as determined by the Engineer.
1. Utilize the following Maintaining Traffic Typicals:
A. 100-GEN-KEY
B. 101-GEN-SPACING-CHARTS
C. 102-GEN-NOTES
D. 110-TR-NFW-2L
2. Do not work, deliver material, or close lanes during the holiday periods as defined in
Table 1. Cover or remove “45 where workers present” signing during the holiday periods as defined in Table 1.
Table 1: 2022 Holiday Periods
Holiday Start Date and Time End Date and Time
Memorial Day 3:00 pm, Friday, May 27th 6:00 am, Tuesday, May 31st
Independence Day 3:00 p.m. Friday, July 1st 6:00 a.m. Tuesday, July 5th
KZO:BCB 2 of 5 04/11/22
3. Maintain a minimum of one lane in alternating direction at all times of work.
A. The maximum closure length is 1 mile unless otherwise approved by the Engineer.
B. Consecutive lane closures on the same bound must originate on the same side of the roadway.
4. Close any dedicated lanes (exit, ramp, turn, etc.) prior to the location under construction.
5. When a lane is closed, place channelizing devices at cross streets and major drives to form a radius that clearly defines the approaches to the through and turning traffic.
6. Maintain access to all driveways as directed by the Engineer unless prior agreements are made with the respective property owners.
e. Traffic General.
1. For any lane open to traffic, provide a minimum lane width of 11 feet with 2 feet of shy distance on both sides unless identified otherwise on plans.
2. Do not close lanes or utilize traffic regulation sequences where work can be accomplished with a shoulder closure. Do not occupy any part of the active traffic lane with personnel or equipment when utilizing a shoulder closure. Place lane closures and traffic regulation operations only in areas as show on the plans unless otherwise directed by the Engineer.
3. A speed reduction will be used. Set the work zone speed limit on US-12 45 miles per hour (mph).
4. Develop and submit to the Engineer an Internal Traffic Control Plan (ITCP) per subsection 104.11.B of the Standard Specifications for Construction. The requirements listed herein are the requirements for a Type A ITCP. Submit the Type A ITCP at the preconstruction meeting. The Engineer will have 7 calendar days to review the ITCP for approval or provide comments for revisions required to obtain approval. Include in the ITCP, at a minimum, the proposed ingress/egress locations for construction equipment and vehicles, traffic control devices that will be utilized to warn the motoring public of ingress/egress locations, and measures that will be taken to ensure compliance with the ITCP. Ensure that the ITCP minimizes conflicts between construction vehicles and motorists and maintains overall safety and mobility within the work zone. No work may begin prior to approval of the ITCP. Additional time required to obtain an approved ITCP will not be cause for delay or impact claims. All costs associated with obtaining an approved ITCP, providing and executing all parts of the approved ITCP including required traffic control devices, or resolving an incomplete or unacceptable ITCP will be borne by the Contractor.
5. The Engineer will be responsible for notifying emergency services, transit agencies, law enforcement and schools prior to any lane closures, detours or major traffic shifts. In addition, the Contractor will be responsible for working with and complying with any coordination that is necessary with the Department and emergency services, transit agencies, KZO:BCB 3 of 5 04/11/22 law enforcement and schools. All costs associated with these coordination efforts will be considered included in the pay item “Minor Traf Devices”.
6. Obtain all necessary permits from local governments within areas of local jurisdiction, including noise/dust ordinance waivers when required, prior to placing construction signing on local roads.
A. The Department will reimburse permit costs in accordance with subsection
107.02.A of the Standard Specification for Construction. Adhere to all requirements made by local maintaining agencies regarding placement of traffic control devices prior to closing lanes on roadways not under MDOT jurisdiction.
7. Remove all temporary traffic control devices from MDOT right-of-way during any shut down periods unless needed for directly maintaining or channelizing traffic. No additional payment will be made for removal and/or redeployment of these devices except for in the case of an approved extension of time.
8. Cover or remove construction signing that refers to work zone speed when work at a location is planned to be inactive for a period greater than 2 days, unless otherwise specified on the plans or as directed by the Engineer.
9. Once work is initiated that includes any lane restrictions, that work must be continued daily until completed. A lack of work activity for more than 3 days will require the removal of lane closures at no expense to the Department.
f. Traffic Regulator Control.
1. Place the arrow panel, signs and channelizing taper for the traffic regulator operation at locations approved by the Engineer for adequate visibility by oncoming traffic.
3. Do not utilize more than 1 traffic regulator operation(s) at one time at locations approved by the Engineer.
3. Crossroads must remain open to traffic at all times. Use intermediate traffic regulators at each intersection approach and commercial driveways within the closure limits, as directed by the Engineer. Use traffic regulator control as directed by the Engineer for cross street traffic while paving through intersections.
4. Follow the Michigan Traffic Regulator’s Instruction Manual for operations at signalized intersections. Contact the MDOT region electrician or applicable maintaining agency prior to work on traffic signals. Only the MDOT region electrician or applicable maintaining agency may make changes to the traffic signal controllers.
g. Hot Mix Asphalt (HMA) Work.
1. Resurface all HMA milled areas the same day as the HMA cold milling operation.
2. No traffic is allowed on the HMA milled surface, unless directed by the Engineer.
h. Traffic Control Devices. Ensure all traffic control devices are in accordance with the
MMUTCD and must meet the “acceptable” criteria as defined in the ATSSA publication entitled http://www.michigan.gov/documents/mdot/MDOT-TrafficRegulatorsManual_327600_7.pdf
KZO:BCB 4 of 5 04/11/22
“Quality Guidelines for Temporary Traffic Control Devices and Features” at the time of initial deployment and after each major stage change.
1. During non-working periods, place applicable advance signs and channelizing devices at specific locations, as directed by the Engineer, at no additional cost to the Department.
2. Notify the Engineer 24 hours in advance of when traffic control devices are being delivered to the project site, to allow for initial inspection of devices to take place.
3. Remove from the project site all traffic control devices (including detour signing) no longer needed for a particular operation and equipment for construction within 14 calendar days of reopening the shoulder/lane/roadway.
4. Channelizing Devices.
A. Ensure all devices have sufficient ballast to prevent moving or tipping. If moving or tipping occurs, place additional ballast, as directed by the Engineer, at no additional cost to the Department. No more than two ballasts are allowed on each channelizing device.
B. Do not use caution tape on this project.
C. Space channelizing devices at 25 for tapers and 50 for tangents or tighter as directed by the Engineer.
5. Temporary Signs.
A. Additional W20-1 (ROAD WORK AHEAD) signs are included in the quantities to be placed on all intersecting or adjacent roads where construction activities may be encountered.
B. Fabricate, install, and remove temporary sign overlays on existing signs with the pay item for Sign, Type B, Temp, Prismatic, Furn. Attach the overlay in accordance with subsection 812.03.D.2 of the Standard Specifications for Construction.
j. Temporary Pavement Markings.
1. Quantities for temporary tape to be placed during paving operations are based on the MDOT PAVE 900 Series standard plans.
2. When Type R or NR tape is used, ensure that all temporary pavement markings adhere to the pavement surface until permanent markings are installed.
3. Replace all existing pavement markings that are removed for traffic control or obliterated during construction.
4. Delineate the edge line using channelizing devices until permanent pavement markings are placed.
KZO:BCB 5 of 5 04/11/22
k. Measurement and Payment. Payment for labor and materials will be considered Lump Sum for Maintaining Traffic. No additional payment will be made for the following activities:
1. Transporting traffic control items from site to site.
2. Providing sufficient vehicles and staff to make changes as-needed on site during work.
3. Providing sufficient vehicles and staff to remove closures from the roadway.
4. Providing additional traffic control devices required to expedite the construction for the convenience of the Contractor.
NOT TO SCALE
FILE:
Michigan Department of Transportation
MAY 2021
A DOUBLE LANE SHIFT
ON A 7-LANE UNDIVIDED ROADWAY
1 BOUND AND CLTL CLOSURE WITH DATE:
SHEET:
NO:
100-GEN-KEY.dgn 3(1R+2L)LC-2(L)SHIFT
152-CLT(7)-
MAINTAINING TRAFFIC TYPICAL
FILE:
Michigan Department of Transportation
DECEMBER 2021
TYPICAL NUMBERING KEY
DATE:
100-GEN-KEY.dgn
MAINTAINING TRAFFIC TYPICAL
100-GEN-KEY
NO:
TYPICAL NUMBER KEY
CODES
ZIP = ZIPPER MERGE
TS = TEMPORARY SIGNAL
TR = TRAFFIC REGULATOR
STA = STOPPED TRAFFIC ADVISORY
SPEED = SPEED
SP = SPECIAL
SIGN = SIGN
SHL = SHOULDER CLOSURE
SD = SHORT DURATION
RUM = RUMBLE STRIP
ROLL = ROLLING ROADBLOCK
(R) = RIGHT
PCMS = PORTABLE CHANGEABLE MESSAGE SIGN
PARK = PARKING LANE
NFW = NON-FREEWAY
MID = MIDDLE OF INTERSECTION OR ROAD
OUT = OUTSIDE OF SHOULDER
O = OUTSIDE (LANE CLOSURE)
LO = LANE OPEN
LD = LONG DURATION
LC = LANE CLOSURE
(L) = LEFT
L = LANE
INT = INTERSECTION
IN = INSIDE
GORE = FREEWAY GORE AREA
GEN = GENERAL INFORMATION
FW = FREEWAY
ExR = EXIT RAMP
EnR = ENTRANCE RAMP
EM = EARLY MERGE
CruSha = CRUSH AND SHAPE
CROSS = CROSSOVER
CLT = CENTER LEFT TURN LANE
C = CLOSURE
AW = ADVANCE WARNING
AB = ARROW BOARD
2(L)SHIFT = 2 LANES SHIFTED TO THE LEFT.
3(1R+2L)LC = 3 LANES CLOSED, (1 RIGHT LANE AND 2 LEFT LANES).
CTL(7) = CENTER LEFT TURN LANE, 7 LANES TOTAL.
152 - TYPICAL NUMBER
CODE: 152-CTL(7)-3(1R+2L)LC-2(L)SHIFT
EXAMPLE TYPICAL
5000 - SURVEY
4000 - MAINTENANCE
360 - ROLLING ROADBLOCK
350 - GORE LOCATIONS
340 - MERGE SYSTEMS
320 - CRUSH AND SHAPE
310 - CROSSOVER CLOSURE
300 - ADVANCE WARNINGS
230 - FREEWAY EXIT RAMPS
220 - FREEWAY ENTRANCE RAMPS
210 - FREEWAY LANE SHIFTS
200 - FREEWAY CLOSURES
160 - SIGNAL WORK
150 - CLT 7 LANE SECTIONS
140 - PARKING LANES
130 - CENTER LEFT TURN (CLT) LANES
120 - NON-FREEWAY
110 - TRAFFIC REGULATORS
100 - GENERAL NOTES
Michigan Department of Transportation
MAY 2021
TRAFFIC TYPICALS
NOTE SHEET
102-GEN-NOTES.dgn
102-GEN-NOTES
NO:
GENERAL NOTES
BUFFER AREAS.
DO NOT STORE EQUIPMENT, MATERIALS OR PERFORM WORK IN ESTABLISHEDG4:
BY MDOT WILL BE ALLOWED.
APPLICABLE SPECIAL PROVISIONS. ONLY DESIGNS AND MATERIALS APPROVED
STANDARD SPECIFICATIONS FOR CONSTRUCTION, THE STANDARD PLANS AND
MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES, THE CURRENT EDITION OF THE
HARDWARE (MASH) TL-3 AS WELL AS THE CURRENT EDITION OF THE MICHIGAN
REPORT 350 (NCHRP 350) TEST LEVEL 3, OR MANUAL FOR ASSESSING SAFETY
LIGHTING MUST MEET NATIONAL COOPERATIVE HIGHWAY RESEARCH PROGRAM
ALL TEMPORARY SIGNS, TYPE III BARRICADES, THEIR SUPPORT SYSTEMS ANDG3:
ARE ADEQUATELY DELINEATED BY OTHER TRAFFIC CONTROL DEVICES.
WILL BE MADE FOR TRAFFIC PATTERNS FOR WORK LESS THAN THREE DAYS THAT
BE REMOVED BEFORE ANY CHANGE IS MADE IN THE TRAFFIC PATTERN. EXCEPTION
CHANGES IN TRAFFIC PATTERNS OR PROPOSED TEMPORARY TRAFFIC MARKINGS SHALL
ALL EXISTING PAVEMENT MARKINGS WHICH ARE IN CONFLICT WITH EITHER PROPOSED G5:
S9:
OF THE STOP SIGN OR IF SIGNALS ARE BEING USED TO CONTROL TRAFFIC.
STOP AHEAD SIGNS ARE NOT REQUIRED IF THERE IS ADEQUATE VISIBILITY
STOP SIGNS NOT REQUIRED IF SIGNALS ARE ON 4-WAY FLASHING RED.
S8:
PLACE THEM "D" DISTANCE APART.
WHEN SPEED LIMIT SIGNS CANNOT BE PLACED SIDE BY SIDE AS SHOWN,
S7:
THE WORK ZONE.
PLACE ADDITIONAL R8-3 SIGNS AT A MAXIMUM 500' SPACING THROUGHOUT
S6:
STANDARDS.
FABRICATE SPECIAL SIGNS IN ACCORDANCE WITH CURRENT SIGNING DESIGN
S4:
THE W20-5 SIGNS.
WHEN TRAFFIC VOLUMES ARE SIGNIFICANT ENOUGH TO CREATE BACKUPS BEYOND
ADDITIONAL SIGNING AND/OR ELONGATED SIGNING SEQUENCES SHOULD BE USED
S2:
AND CONSOLIDATE THE SEQUENCE AS APPROPRIATE.
OR LONGER. TO APPLY THIS TYPICAL WITHOUT R5-18b SIGNS, REMOVE THE SIGNS
15 DAYS OR LONGER OR NON-FREEWAY PROJECTS WITH A DURATION OF 90 DAYS
R5-18b SIGNS ARE ONLY REQUIRED ON FREEWAY PROJECTS WITH A DURATION OF
S3:
OMIT THIS SIGN IN SUBSEQUENT SEQUENCES IN THE SAME WORK ZONE.
R5-18c IS ONLY REQUIRED IN THE INITIAL SIGNING SEQUENCE IN THE WORK ZONE.
SIGN NOTES
S5:
ACCORDINGLY.
SPEED LIMIT ARE POSTED, OMIT ALL W3-5b AND R2-1 SIGNS AND REDUCE SPACING
OF THE WORK AREA AS INDICATED. IF PERMANENT SIGNS DISPLAYING THE CORRECT
SPEED LIMIT SIGNS RETURNING TRAFFIC TO ITS NORMAL SPEED BEYOND THE LIMITS
WHEN REDUCED SPEED LIMITS ARE UTILIZED IN THE WORK AREA, PLACE ADDITIONAL
ROADWAY SUCH THAT NO SPEED LIMIT SIGNS ARE MORE THAN 2 MILES APART.
IS IN EFFECT. PLACE ADDITIONAL SPEED LIMIT SIGNS AT INTERVALS ALONG THE
ENTRANCE RAMP THAT COMES ONTO THE FREEWAY WHERE THE REDUCED SPEED
EACH MAJOR CROSSROAD THAT INTERSECTS THE WORK ZONE, OR AFTER EACH
PLACE ADDITIONAL SPEED LIMIT SIGNS REFLECTING THE WORK ZONE SPEED AFTER
S1:
SAFETY AND MOBILITY MANUAL, SECTIONS 6.01.09 AND 6.01.10.
CONDITIONS, COVERED, OR REMOVED. FOR GUIDANCE SEE THE WORK ZONE
ALL NON-APPLICABLE SIGNING WITHIN THE CIA MUST BE MODIFIED TO FIT
TCD8:
REVERSE CURVE SIGN, AND THE SECOND REVERSE CURVE SIGN CAN BE OMITTED.
REVERSE CURVE SIGN (W24-1) CAN BE USED INSTEAD OF THE FIRST
WHERE THE SHIFTED SECTION IS SHORTER THAN 600 FEET, A DOUBLE
TYPE III BARRICADES MUST BE LIGHTED FOR OVERNIGHT CLOSURES.TCD3:
"ROAD CLOSED" EXTENDING COMPLETELY ACROSS THE HAUL ROAD.
WHEN THE HAUL ROAD IS NOT IN USE, PLACE LIGHTED TYPE III BARRICADES WITHTCD4:
TEMPORARY TRAFFIC CONTROL DEVICE NOTES
TCD7:
OFF ROAD FROM EDGE OF PAVEMENT TO EDGE OF PAVEMENT.
ADDITIONAL TYPE III BARRICADES MAY BE REQUIRED TO COMPLETELY CLOSE
TCD9:
ARE NOT TO EXCEED 50 FEET AT NIGHT.
45 MPH OR GREATER. THE SPACING FOR 42 INCH CHANNELIZING DEVICE TANGENTS
EXCEED 100 FEET ON ROADWAYS WITH A POSTED WORK ZONE SPEED LIMIT OF
WITH A POSTED WORK ZONE SPEED LIMIT LESS THAN 45 MPH AND SHOULD NOT
SHOULD NOT EXCEED TWICE THE WORK ZONE SPEED LIMIT IN MPH FOR ROADWAYS
THE MAXIMUM DISTANCE IN FEET BETWEEN CHANNELIZING DEVICES IN A TANGENTTCD2:
TAPERS ARE NOT TO EXCEED 25 FEET AT NIGHT.
LIMIT OF 45 MPH OR GREATER. THE SPACING FOR 42 INCH CHANNELIZING DEVICE
SHOULD NOT EXCEED 50 FEET ON ROADWAYS WITH A POSTED WORK ZONE SPEED
ROADWAYS WITH A POSTED WORK ZONE SPEED LIMIT LESS THAN 45 MPH AND
SHOULD NOT EXCEED 1.0 TIMES THE WORK ZONE SPEED LIMIT IN MPH FOR
THE MAXIMUM DISTANCE IN FEET BETWEEN CHANNELIZING DEVICES IN A TAPERTCD1:
AT A CONSISTENT DISTANCE, BETWEEN 10' AND 20' APART.
THREE RUMBLE STRIPS. PLACE THE RUMBLE STRIPS IN THE ARRAY
RECOMMENDATIONS. AN ARRAY OF RUMBLE STRIPS CONTAINS
SHOWN, AND IN ACCORDANCE WITH THE RUMBLE STRIP MANUFACTURER'S
IF NOT SPECIFIED IN THE CONTRACT, PLACE RUMBLE STRIPS AS
RUMBLE STRIPS ARE TO BE PLACED AS SPECIFIED IN THE CONTRACT.
RAMP NOTES
DIVERGE IN A FREE MANNER
CHANELIZING DEVICES MUST BE POSITIONED TO ENABLE RAMP TRAFFIC TO
WHEN CONDITIONS ALLOW, E5-1 SIGNS MUST BE REMOVED OR COVERED ANDRMP1:
WORK SHOULD BE EXPEDITED TO AVOID THE STOP AND/OR YIELD CONDITIONS.
THE RAMP TO COMPLETE WORK TO ALLOW AN ADEQUATE MERGE DISTANCE.
IN PLACE OF W3-2 SIGNS. CONSIDERATION SHOULD BE GIVEN TO CLOSING
R1-2 SIGNS. WHEN R-1 SIGNS ARE USED, W3-1 SIGNS MUST BE USED
WHEN CONDITIONS WARRANT, R1-1 SIGNS MAY BE USED IN PLACE OF
STOP AND YIELD CONDITIONS SHOULD BE AVOIDED WHENEVER PRACTICAL.RMP2:
G2:
THE ENGINEER.
GEN-KEY ARE APPROXIMATE AND MAY NEED ADJUSTING AS DIRECTED BY
DISTANCE BETWEEN SIGNS, "D", THE VALUES FOR WHICH ARE SHOWN IN TYPICAL
BOARD IN THE CLOSED LANE AS CLOSE TO THE BEGINNING OF TAPER AS POSSIBLE.
SECTIONS, IF ARROW BOARD CANNOT BE PLACED BEHIND CURB, PLACE ARROW
MOTORISTS WHEN PHYSICAL LIMITATIONS RESTRICT PLACEMENT. IN CURBED
PRACTICAL, BUT NOT IN A MANNER THAT WILL OBSCURE OR CONFUSE APPROACHING
PLACE LIGHTED ARROW PANELS AS CLOSE TO THE BEGINNING OF TAPERS AS TCD6:
S10:
A SPEED REDUCTION IN THIS DIRECTION.
PLACE REDUCED SPEED ZONE AHEAD SIGN (W3-5b) HERE WHEN USING
TCD10:
SIDES OF THE ROAD 1000 FEET FROM EACH OTHER.
CORRECT PCMS MESSAGING. STAGGER PCMS THAT ARE ON OPPOSING
CHANGEABLE MESSAGE SIGN GUIDELINES FOR RECCOMENDED AND
SEE THE WORK ZONE SAFETY AND MOBILITY MANUAL, PORTABLE
WHEN USED WITH A TEMPORARY SIGNAL SYSTEM.
IN THE STANDARD PLAN FOR TEMPORARY CONCRETE BARRIER (R-53, AND R-126)
USE VERTICAL PANELS IN LIEU OF THE TYPE B HIGH INTENSITY LIGHT SHOWNTCD5:
ROLL AHEAD DISTANCE
B = LENGTH OF LONGITUDINAL BUFFER
L = MINIMUM LENGTH OF TAPER
D = DISTANCE BETWEEN TRAFFIC CONTROL DEVICES
SEE GEN-SPACING-CHARTS FOR COMMON VALUES INCLUDING:G1:
TRAFFIC REGULATOR NOTES
TR1:
BY THE ROADWAY ADT, GEOMETRICS, AND AS DIRECTED BY THE ENGINEER.
THE MAXIMUM DISTANCE BETWEEN THE TRAFFIC REGULATORS IS DETERMINED
AND THE VIDEO "HOW TO SAFELY REGULATE TRAFFIC IN MICHIGAN".
THE CURRENT VERSIONS OF THE TRAFFIC REGULATOR'S INSTRUCTION MANUAL
SPECIFICATIONS, THE STANDARD PLANS AND APPLICABLE SPECIAL PROVISIONS,
TRAFFIC REGULATORS MUST FOLLOW ALL THE REQUIREMENTS IN THE STANDARD
TR2:
THE HOURS OF DARKNESS.
REGULATOR'S STATIONS WHEN TRAFFIC REGULATING IS ALLOWED DURING
PROVIDE APPROPRIATE BALLOON LIGHTING TO SUFFICIENTLY ILLUMINATE TRAFFIC
S11:
LENGTH OF SHIFT AND AS PER THE ENGINEER.
SHIFTS MORE THAN 12FT, PLACE THREE OR MORE W1-6(R)(L) SIGNS DEPENDING UPON
SHIFTS 5FT TO 12FT, PLACE TWO W1-6(R)(L)
SHIFTS 4FT OR LESS, PLACE ONE W1-6(R)(L)
THE NUMBER OF W1-6 SHIFT SIGNS TO PLACE FOR A SHIFT IS AS FOLLOWS:
S12:
IN THIS DIRECTION
PLACE R2-1 SIGNS AS DETAILED IN NOTE S5 WHEN THERE IS A SPEED REDUCTION
THE FOLLOWING NOTES APPLY IF CALLED FOR ON THE TRAFFIC TYPICAL
MAY 2021
TRAFFIC TYPICALS
NOTE SHEET
102-GEN-NOTES.dgn
102-GEN-NOTES
NO:
SIGNAL NOTES
TRUCK IS LOCATED OVER ACTIVE TRAVEL LANES.
THE CONTRACTOR MUST HAVE A DESIGNATED SPOTTER IF THE AERIAL BUCKETSIG4:
INTERSECTION WHEN TRAFFIC IS PLACED IN A 4 WAY STOP.
COMPROMIZED. USE TRAFFIC REGULATORS TO CONTROL TRAFFIC THROUGH THE
THE INTERSECTION IN A 4 WAY STOP IF THE 14 FOOT VERTICAL CLEARANCE IS
CLEARANCE. THE CONTRACTOR MUST UTILIZE AN ALTERNATE SET UP, OR PLACE
THE LOWEST POINT OF THE BUCKET MAY NOT TRAVEL BELOW 14 FOOT VERTICALSIG5:
TRUCK MAY BE MOVED TO FACILITATE WORK.
DELINEATE THE TRUCK WITH CHANNELIZING DEVICES. THE POSITION OF THESIG6:
42 INCH CHANNELIZING DEVICES FOR NIGHTTIME WORK.
DELINEATE THE WORK ZONE AREA WITH 28 INCH CONES FOR DAYTIME WORK, ORSIG3:
SIGNAL IS IN OPERATION.SIG2:
EXISTING SIGNAL MUST BE EITHER 4-WAY FLASHING RED, BAGGED, OR TURNED OFF.SIG1:
MAINTENANCE AND SURVEYING NOTES
ACTIVATED AMBER BEACON.
WORK AND SHADOW VEHICLES SHALL BE APPROPRIATELY EQUIPPED WITH AN MS4:
SIGHT DISTANCE IN ADVANCE OF VERTICAL OR HORIZONTAL CURVES.
SLOW DOWN AND TRAVEL AT A FARTHER DISTANCE TO PROVIDE ADEQUATE
AREA AND PROCEEED AT THE SAME SPEED. THE SHADOW VEHICLE SHOULD
VEHICLES SHOULD MAINTAIN THE RECOMENDED DISTANCE FROM THE WORK
WHENEVER STOPPING SIGHT DISTANCE EXISTS TO THE REAR, THE SHADOW MS1:
TABLES.
SHOULD BE PARKED ACCORDING TO THE ROLL AHEAD DISTANCE
SEPARATE THE WORK SPACE FROM TRAFFIC. IF USED, THE VEHICLES
WORK OR SHADOW VEHICLES WITH OR WITHOUT A TMA MAY BE USED TO MS3:
TO) IS THE LAYOUT OF CONCRETE PATCHES.
SPACING MUST BE USED. AN EXAMPLE OF AN OPERATION (BUT NOT LIMITED
CHANNELIZING DEVICES TO DELINEATE OPEN OR CLOSED LANES AT 50 FT
A MOBILE OPERATION IS OCCURRING DURING THE NIGHTTIME HOURS,
WHEN WORKERS ARE OUTSIDE THEIR VEHICLES IN AN EXISTING LANE WHILEMS5:
TYPE OF WORK TAKING PLACE AS PER THE ENGINEER.
W21-6 AND W20-1 SIGNS MAY BE SUBSTITUTED AS DETERMINED BY THE MS6:
"END ROAD WORK" SIGN.
AND THE "END WORK CONVOY" SIGN, OR BETWEEN THE "WORK ZONE BEGINS" AND
WITH AN ACTIVATED BEACON, BETWEEN THE "BEGIN WORK CONVOY" SIGN
WORKERS OUTSIDE OF VEHICLES SHOULD WORK WITHIN 150' OF WORK VEHICLES MS2:
THE FOLLOWING NOTES APPLY IF CALLED FOR ON THE TRAFFIC TYPICAL
MAY 2021
UTILIZING TRAFFIC REGULATORS
ON A 2-LANE UNDIVIDED ROADWAY
LANE CLOSURE DATE:
110-TR-NFW-2L.dgn
110-TR-NFW-2L
NO:
S H
O U
L D
E R
S H
O U
L D
E R
LIMIT
SPEED
XX
R2-1
V A R
IE
S
W O R K
A R E A
50' TO 100' MAXIMUM
W3-4
TOSTOP
PREPARED
BE
W3-4
TOSTOP
PREPARED
BE
LIMIT
SPEED
XX
R2-1
LIMIT
SPEED
XX
R2-1
ROAD WORK
END
G20-2
ROAD WORK
END
G20-2
W20-7a
BEGINS
ZONE
WORK
R5-18c
INJURE /
KILL A
WORKER
7500$
15 YEARS
R5-18b
ONE LANE
ROAD
AHEAD
W20-4
ROAD
WORK
AHEAD
W20-1
LIMIT
SPEED
XX
R2-1
ROAD
WORK
AHEAD
W20-1
W20-7a
ONE LANE
ROAD
AHEAD
W20-4
BEGINS
ZONE
WORK
R5-18c
W3-5b
ZONE
AHEAD
REDUCED
SPEED
B
LIMIT
SPEED
XX
R2-1
LIMIT
SPEED
XX
R2-1
D
D
D
D
D D
D D
D
D
D
W3-5b
ZONE
AHEAD
REDUCED
SPEED
D
D
D
D
INJURE /
KILL A
WORKER
7500$
15 YEARS
R5-18b
KEY
PLACE SIGN AS INDICATED IN NOTE S2
PLACE SIGN AS INDICATED IN NOTE S5
REFLECTS EXISTING SPEED LIMIT
TRAFFIC FLOW
LIGHTED ARROW PANEL (CAUTION MODE)
CHANNELIZING DEVICES
TRAFFIC REGULATOR
L
L1
D
D
DEVICES:
TRAF REG:
SIGNING:
GENERAL:
TCD1, TCD2, TCD6
TR1, TR2
S1, S2, S3, S4, S5
G1, G2, G3, G4
STANDARD NOTES
(SEE GEN-NOTES)
(ft )
SIGN AREA
9_<
9 _ 20<
N/A1 - 3 lb/ft
2 - 3 lb/ft 1 - 4" X 6"
2 - 4" X 6"
2 - 6" X 8"N/A
N/A
SIGNS 4 FEET AND GREATER IN WIDTH REQUIRE 2 POSTS.
36" X 36"
> X
X
X X
1 - 2" 12 or 14 GA
2 - 2" 12 or 14 GA
X
X> 144" WIDE
ROUNDING OF CORNERS IS NOT REQUIRED FOR TYPE I OR II SIGNS.
VERTICAL JOINTS ARE NOT PERMITTED.
HORIZONTIAL JOINTS THROUGH SIGN LEGEND OR SYMBOLS ARE NOT PERMITTED.
A MAXIMUM OF 2 POSTS WITHIN A 7' PATH IS PERMITTED.
<> N/A 3 - 6" X 8"
SIGNS GREATER THAN 8 FEET IN WIDTH REQUIRE 2 OR 3 WOOD
POSTS DEPENDING ON AREA OF SIGN.
36" X 36" _ 96" TO WIDE
POST TYPE
2 WOODSQUARE TUBULAR STEELU-CHANNEL STEEL
20 _ 30
N/A
N/A
POST SIZE REQUIREMENTS TABLE
SIGN MATERIAL SELECTION TABLE
SIGN SIZE TYPE I TYPE II TYPE III
SIGN MATERIAL TYPE
TYPE I ALUMINUM EXTRUSION
30 _ 60
60 _ 84 N/A
96" WIDE TO 144" WIDE
SUPPORTS FOR TEMP SIGNS
GROUND DRIVEN SIGN
WZD-100-AAUG
CON/ECH
1 11 11/2/2017
DEPARTMENT DIRECTOR MICHIGAN DEPARTMENT OF TRANSPORTATION
OF
SHEET
PLAN DATEF.H.W.A. APPROVALCHECKED BY:
DRAWN BY:
Michigan Department of Transportation
APPROVED BY:
APPROVED BY:
Kirk T. Steudle
BY
PREPARED
DESIGN DIVISION
DIRECTOR, BUREAU OF FIELD SERVICES
BUREAU OF DEVELOPMENT STANDARD PLAN FOR
DIRECTOR, BUREAU OF DEVELOPMENT
DISTANCE BETWEEN OUTSIDE POSTS.
SPREAD POSTS SO AS TO HAVE A 8' MIN. TO 9' MAX.
FOR ALL 11' AND 12' LONG SIGNS ON 3 WOOD SUPPORTS,
SIGN
L
2 POST SIGN SUPPORT SPACING
1/6L 1/6L2/3L
SIGN
L
1/6L 1/6L
3 POST SIGN SUPPORT SPACING
1/3L 1/3L
2 11
11/2/2017 WZD-100-A
MICHIGAN DEPARTMENT OF TRANSPORTATION
PLAN DATEF.H.W.A. APPROVAL
SHEET
OF
NOTE: THE ORIGINAL SIGNED COPY IS KEPT ON FILE AT THE MICHIGAN DEPARTMENT OF TRANSPORTATION.
BUREAU OF DEVELOPMENT STANDARD PLAN
AHEAD
CLOSED
ROAD
ROAD
WORK
AHEAD
DETOUR
AHEAD
AHEAD
CLOSED
RIGHT LANE
M.P.H.
BOTTOM HEIGHT AND OFFSET
6'-12' 6'-12'
6'
RURAL
URBAN
5' MIN.
2'
7' MIN.
2'
7'MIN.
4'MIN.
URBAN
4" MAX.4" MAX.
WZD-100-A
3 11
PAVED SHOULDER
SPEED PLATE
RURAL WITH ADVISORY
WALKWAY WALKWAY
WALKWAYS ARE PRESENT)
(CURBED AREAS OR WHERE
WALKWAYS ARE PRESENT)
(CURBED AREAS OR WHERE
11/2/2017
SHEET
OF
C
X X
P O
S T
N G
H
V
R I
E S
3 3/4" MAX.
I
O
L
M
N
N
X
3" MIN.
X X
TRAFFIC FLOW
WEIGHT = 3 lbs/ft
1" MIN.
1†" MAX.
L
SECT. MOD. X.-X. = 0.31 CUBIC INCHES MIN.
WZD-100-A 4 11
U - CHANNEL STEEL POST
MOUNT SIGN ON OPEN FACE OF
(NO SPLICE)
3 lb. U - CHANNEL STEEL POST
SHEET
OF
A A
N
N
U P
P
R
P
S T
N
P
UPPER SPLICE LOWER SPLICE
A A
N
P
TRAFFIC FLOW
U P
P
S T
D R I
V
U B
D R I
V
U B
5 11
UPPER U - CHANNEL STEEL POST
MOUNT SIGN ON OPEN FACE OF
2 REQUIRED
5/16" BOLTS
2 REQUIRED
5/16" BOLTS
2 REQUIRED
5/16" BOLTS
2 REQUIRED
5/16" BOLTS
(WITH SPLICE)
3 lb. U - CHANNEL STEEL POST
SHEET
OF
7/16"
NOTES:
UPPER POSTDRIVEN POST
TRAFFIC FLOW
5/16" BOLT
SPACER DETAIL
3/4" O.D.
3/8" I.D.
SPACER THICKNESS
SECTION A-A
1. THE SPACER THICKNESS SHALL BE 1/16" LESS THAN THE GAP BETWEEN THE POST
WHEN POSITIONED IN THE UNBOLTED CONFIGURATION.
2. THE EXTERIOR BOLT (CLOSEST TO LAP), SPACER, WASHER, AND NUT SHALL BE
INSTALLED IN A PREPUNCHED HOLE 1" to 2" FROM THE END OF THE LAP.
3. THE INTERIOR BOLT (FARTHEST FROM LAP), SPACER, WASHER, AND NUT SHALL BE
INSTALLED IN THE NEXT PREPUNCHED HOLE.
4. THE DRIVEN POST SHALL ALWAYS BE MOUNTED IN FRONT OF THE UPPER POST
WITH RESPECT TO THE ADJACENT ONCOMING TRAFFIC, REGARDLESS OF THE
DIRECTION THE SIGN IS FACING.
5. THE SPLICE LAP SHALL BE FASTENED BY FOUR-5/16" DIA. GALVANIZED A449 BOLTS
(SAE J429 GRADE 5) OR GALVANIZED A325 BOLTS.
6 11
(WITH SPLICE)
3 lb. U - CHANNEL STEEL POST
O.D. 3/4" MIN., I.D. 3/8" MAX.
REQUIRED FOR ALL BOLTS
7/16" SPACER
SHEET
OF
3# POST
VARIES VARIES VARIES
A
A
SECTION A-A
FRONT
1. MATERIAL: 12 GAUGE CARBON STEEL.
3. FINISH-AFTER STAMPING AND PUNCHING,
GALVANIZE ACCORDING TO CURRENT
3 1/2"
1 3/4" 1 3/4"
7/16" DRILL
EQUAL TO POST THROAT
OPENING DIMENSION
2. TOLERANCE ON ALL DIMENSIONS 0.0625"
SPECIFICATIONS FOR ZINC (HOT
GALVANIZE) COATINGS ON PRODUCTS
FABRICATED FROM PLATES OR STRIPS
NOTES: (FOR STEEL SIGN REINF' PLATE)
0.19" R
PLYWOOD (TYPE II) OR ALUMINUM SHEET (III) SIGN
STEEL SIGN REINFORCING PLATE
SIGN TO 3 lb. POST CONNECTION
3 lb. U - CHANNEL STEEL POST SIGN CONNECTION
REQUIRED FOR TYPE III SIGNS ONLY
5/16" DIAMETER GALVANIZED BOLT
AND NUT
FLAT WASHER
WZD-100-A 7 11
(TYP. ALUMINUM SHEET [TYPE III] SIGN ONLY)
REINFORCING PLATE
SELF-ALIGNING STEEL
SHEET
OF
(4" X 6" (NOMINAL) POST) 1 1/2" DIA. 2 HOLES
(6" X 8" (NOMINAL) POST) 3 1/2" DIA. 2 HOLES
N
8" DIA. AUGERED HOLE FOR 4" X 6" POST
10" DIA. AUGERED HOLE FOR 6" X 8" POST
5•" OR 7•" (ACTUAL)
SAW CUT DETAIL
5 1/2 " OR 7 1/2" ACTUAL
TRAFFIC FLOW
WOOD POST DETAILS
(MULTIPLE POST INSTALLATIONS)
TRAFFIC FLOW
SIGN PANEL
CONSTRUCTION.
THE STANDARD SPECIFICATIONS FOR
SECTION 912 OF THE CURRENT EDITION OF
WOOD POST SHALL BE IN CONFORMANCE TO
WZD-100-A 8 11
LAYERS, TAMPING EACH LAYER.
EXISTING MATERIAL IN FIVE EQUAL
AUGERED HOLE. IF AUGERED, BACKFILL WITH
THE POST MAY BE DRIVEN OR PLACED IN AN
S I
N G
S E
M B
L I
E S
W
U
T
E X
C E
P T
I
N
(FOR 6" X 8" NOMINAL POST) 1 1/2"
(FOR 4" X 6" NOMINAL POST) 1"
CENTERED ON POSTS.
HOLES ARE TO BE
DRILLED BREAKAWAY
DIRECT EMBEDMENT DETAILS
WOOD POST BREAKAWAY HOLES/
SHEET
OF
POST ASSEMBLIES
EXCLUDE SAW CUT ON SINGLE
SAME AS BOLT ABOVE
TYPE II AND TYPE III SIGNS
END VIEW REAR VIEW
C OF POST
1 1/2"
(TYP.)
P A
N E
L
W I
D T
H
TOP VIEW
LENGTH ALL EXTRUSIONS.
L
1/2"
O
T Y
P
12"
T Y
P
4" X 6" (NOMINAL) OR 6" X 8" (NOMINAL) WOOD POST
ON APPROX. 24" CENTERS FULL
TYPE I SIGN
WOOD POST CONNECTIONS
TYPE I SIGN - ERECTION DETAILS
L
1/6 SIGN LENGTH
(TYP.)
3/8" DIA. GALVANIZED BOLTS
WZD-100-A
(TYP.)
1 1/2"
(TYP.)
STIFFENER ANGLE
SPACING
HOLE
TYPICAL
ALIGNMENT OF PANELS.
USED TO FACILITATE
E
X
N
X
N
TYP.
2"
BOLT HOLES MAY BE
1/2" X 3/4" ELONGATED
M A
X
M A
X
CORNER RADIUS (TYP.)
0.040" EXTERIOR
(ALUM.) x SIGN HEIGHT
L 2" X 2" X 1/4"
STIFFENER ANGLE-
FOR CONSTRUCTION
SPECIFICATIONS
PER MDOT STANDARD
ALUMINUM EXTRUSION
SIGNS
ALUMINUM SHEET (TYPE III)
PLYWOOD (TYPE II) OR
(TYPE I) SIGN
ALUMINUM EXTRUSION
SAW CUT
FLAT WASHER
GALVANIZED
HEX. HD. BOLT
3/8" DIA. GALVANIZED
NYLON INSERT LOCKNUT
GALVANIZED
FLAT WASHER
GALVANIZED
NYLON INSERT LOCKNUT (TYP.).
WASHERS & GALVANIZED
2 GALVANIZED FLAT
3/8" DIA. GALVANIZED BOLT,
BE INSTALLED ON EITHER SIDE OF EACH POST.
ALUMINUM L 4" X 3" X 3/8" ANGLES MAY
GALVANIZED BOLTS.
C OF HOLES FOR 3/8" DIA.
ALIGNMENT OF ALUMINUM ANGLES.
HOLES MAY BE USED TO FACILITATE
1/2" X 3/4" ELONGATED BOLT
EACH PANEL.
BOLT STIFFENER ANGLE TO
NYLON INSERT LOCKNUTS.
& GALVANIZED
GALVANIZED FLAT WASHERS
RECTANGULAR FLAT BOLTS,
GALVANIZED 3/8" DIA.
9 11
SHEET
OF
N G
V
R I
E S
ANCHOR SLEEVE
GRADE
SQUARE TUBULAR STEEL POST
M I
N
N
L
TUBE SIZE = 2•" X 2•"
WALL THICKNESS = 12 GA
W
P O
S I
F
U
D E
S
SIGN POST
TUBE SIZE = 2" x 2"
WALL THICKNESS =12 OR 14 GA
X
INSERT CONNECTION HARDWARE
(PER MANUFACTURER'S
SPECIFICATIONS)
WZD-100-A
SIGN CONNECTION LOCATIONS.
ANCHOR/POST CONNECTION AND
HOLES OPTIONAL EXCEPT FOR
10 11
SHEET
OF
1. A MAXIMUM OF TWO POSTS WITHIN A 7 FOOT PATH IS PERMITTED.
GENERAL NOTES:
3. ALL POSTS SHALL BE EMBEDDED A MINIMUM OF 42".
2. ALL SIGN POSTS SHALL COMPLY WITH NCHRP 350.
13. POSTS SHALL NOT EXTEND MORE THAN 4" ABOVE TOP OF SIGN.
10. REMOVE SIGN POSTS AND/OR POST STUBS IN THEIR ENTIRETY WHEN NO LONGER
REQUIRED.
11. ALL LABOR, MATERIALS, AND EQUIPMENT, INCLUDING TEMPORARY SUPPORTS
12. SAW CUTS IN WOOD POSTS ARE TO BE PARALLEL TO THE BOTTOM OF THE SIGN.
4. BRACING OF POST IS NOT PERMITTED.
5. SIGN SHALL BE LEVEL, AND UPRIGHT FOR THE DURATION OF INSTALLATION.
6. ERECT POSTS SO THE SIGN FACE AND SUPPORTS DO NOT VARY FROM PLUMB
BY MORE THAN 3/16" IN 3'. PROVIDE A CENTER-TO-CENTER DISTANCE
BETWEEN POSTS WITHIN 2 PERCENT OF PLAN DISTANCE.
7. NO MORE THAN ONE SPLICE PER POST, AS SHOWN, WILL BE PERMITTED.
8. POST TYPES SHALL NOT BE MIXED WITHIN A SIGN SUPPORT INSTALLATION.
WZD-100-A
THROUGH SIGN LEGEND OR SYMBOLS ARE PERMITTED IN SIGN
9. NO VERTICAL JOINTS ARE PERMITTED IN SIGN. NO HORIZONTIAL JOINTS
11 11 11/2/2017
REQUIRED TO INSTALL, MAINTAIN, RELOCATE, AND/OR REMOVE THE TEMPORARY
SIGN, INCLUDING SUPPORTS, ARE CONSIDERED TO BE INCLUDED IN THE COST
OF THE TEMPORARY SIGN.
14. TEMPORARY WOOD SUPPORTS DO NOT REQUIRE PRESERVATIVE TREATMENT.
SHEET
OF
ECH
MWB
ENGINEER OF DEVELOPMENT
Traffic Control Devices
Temporary
WZD-125-E 1 3
6" MIN.
12" MAX.1
8'-0" o
(12 REQUIRED)
1" MIN. O.D. STEEL FLAT LOCK WASHER
…" - 16 STEEL HEX NUT
…" - 16 STEEL HEX BOLT
6" MIN.
12" MAX.1
8'-0" o
(12 REQUIRED)
1" MIN. O.D. STEEL FLAT LOCK WASHER
…" - 16 STEEL HEX NUT
…" - 16 STEEL HEX BOLT
FRONT ELEVATION SIDE VIEW
FRONT ELEVATION SIDE VIEW
PERFORATED SQUARE STEEL TUBE OPTION
BI-DIRECTIONAL RIGHT DIRECTIONALLEFT DIRECTIONAL
T Y
P
T Y
P
ANGLE IRON OPTION
(12 GAGE)
SQUARE STEEL TUBE
1ƒ" PERFORATED
(10 GAGE)
1•" x 1•" ANGLE
C
C C
C C
C C
C ƒ" HOLLOW EXTRUDED RIGID POLYOLEFIN ƒ" HIGH DENSITY POLYETHYLENE OR ƒ" ACX PLYWOOD OR
BARRICADE RAIL MAY BE
ƒ" HOLLOW EXTRUDED RIGID POLYOLEFIN ƒ" HIGH DENSITY POLYETHYLENE OR ƒ" ACX PLYWOOD OR
BARRICADE RAIL MAY BE
CLOSURES
(TYPICAL)
ORANGE
REFLECTORIZED
(TYPICAL)
SILVER (WHITE)
REFLECTORIZED
(TYPICAL)
SILVER (WHITE)
REFLECTORIZED
(TYPICAL)
ORANGE
REFLECTORIZED
BARRICADE RAIL SHEETING OPTIONS
TYPE III BARRICADES
(12 GAGE)
2" SQUARE STEEL TUBE
4'-0" - 6'-0"
4'-0" - 6'-0"
(12 GAGE)
2" SQUARE STEEL TUBE8
O R
2" x 2" x ‰" ANGLE
2" x 2" x ‚" ANGLE OR OF BASE
WELD TO CENTER
OF BASE
WELD TO CENTER
" 1•" x 1•" ANGLE (10 GAGE)
2" x 2" x ‰" ANGLE OR
2" x 2" x ‚" ANGLE OR http://safety.fhwa.dot.gov/roadway_dept/road_hardware/wzd.htm
Other Type III Barricades meeting current NCHRP crash worthy criteria can be found on the FHWA Safety website at
(SPECIAL DETAIL) 1/18/11
THROUGH UPRIGHT AND RAIL
WITH VANDAL RESISTANT HARDWARE
LIGHTWEIGHT WARNING LIGHT ATTACHED
THROUGH UPRIGHT
WITH VANDAL RESISTANT HARDWARE
LIGHTWEIGHT WARNING LIGHT ATTACHED
DEPARTMENT DIRECTOR MICHIGAN DEPARTMENT OF TRANSPORTATION
OF
SHEET
PLAN DATEF.H.W.A. APPROVALCHECKED BY:
DRAWN BY:
Michigan Department of Transportation
APPROVED BY:
APPROVED BY:
Kirk T. Steudle
BY
PREPARED
DESIGN DIVISION
DIRECTOR, BUREAU OF FIELD SERVICES
BUREAU OF DEVELOPMENT STANDARD PLAN FOR
DIRECTOR, BUREAU OF DEVELOPMENT
6'-0"
(4 REQUIRED)
STEEL HEX BOLT WITH Œ" NUT
…" x 2•" - 16 ZINC COATED
1" ON CENTER, ALL FOUR SIDES
PSST STEEL TUBING WITH …" HOLES
12 OR 14 GAGE GALVANIZED UPRIGHT
1ƒ" x 1ƒ" x 9'-0"
REFLECTIVE SHEETING
3'-4"
PLACED 6" FROM BOTTOM OF UPRIGHT
1" ON CENTER, ALL FOUR SIDES
PSST STEEL TUBING WITH …" HOLES
12 GAGE GALVANIZED SLEEVE
2" x 2" x 3'-0"
ON THREE SIDES
IRON BY ‚" x 2" WELDS
ATTACH STUB TO ANGLE
FOR INSERTING UPRIGHT
6" HIGH (12 GAGE)
2" SQUARE STEEL TUBE
FRONT ELEVATIONSIDE VIEW
TEMPORARY SIGN SUPPORT
(WARNING LIGHT PLACED ON SIDE CLOSEST TO TRAFFIC)
T
Y P
Z-BRACKET DETAIL
1‚"
1ƒ"
14 GAGE STEEL
3"
1•"1•"
Œ" DIA. HOLE
ƒ
PLACED IN OUTERMOST SLOT
AND BATTERY MUST BE
OF SIGN A MINIMUM OF 1"
MUST PROTRUDE FROM EDGE
WARNING LIGHT HOUSING
FROM THE EDGE LINE OF THE PANEL
WITH BOLT PROTECTION CUP. LOCATE BOLT 2" IN
Z-BRACKET ATTACHED WITH •" x 4" HALF MOON BOLT
WITH 6 VOLT SINGLE LANTERN TYPE BATTERY HELD BY
LIGHTWEIGHT (3.3 LBS. MAX.) WARNING LIGHT TYPE A
2" x 2" x ‰" ANGLE *
2" x 2" x ‚" ANGLE OR
* SIGN STAND IS BALLASTED WITH FOUR OR MORE 35 LB SANDBAGS. A MINIMUM OF ONE ON EACH END.
UPRIGHTS SHALL NOT EXTEND ABOVE THE SIGN PANEL.
(OPTIONAL)
INSERTED IN THE HOLE OF PANEL
NYLON WASHER (SEE DETAIL BELOW)
TIGHTENED TO CUP WASHER
AND 1•" FLAT WASHER ˆ" THICK
STEEL HEX BOLT WITH Œ" NUT
…" x 3" - 16 ZINC COATED
1‚" DIA. HOLE IN PANEL FOR
OPTIONAL NYLON WASHER
…" DIA. HOLE
„"1„"
(MEDIUM DENSITY OVERLAY PLYWOOD)
48" x 48" x •" PANEL http://safety.fhwa.dot.gov/roadway_dept/road_hardware/wzd.htm
Other temporary sign supports meeting current NCHRP crash worthy criteria can be found on the FHWA Safety website at
R U
R A
U R
B A
N
1/18/11SPECIAL DETAIL WZD-125-E 2 3
SHEET
OF
WZD-125-E
NOTES:
PLASTIC DRUM
A P
P R
O X
REMAINDER OF DRUM
2" MAX.
NON REFLECTORIZED ORANGE
REFLECTORIZED WHITE
REFLECTORIZED ORANGE
X
S
T E
18" MIN.
SYMBOLS TO BE USED ON PLANS
EXISTING TYPE III BARRICADE
PROPOSED TYPE III BARRICADE
PLASTIC DRUM
TRAFFIC CONTROL DEVICE.
SO THEY WILL NOT COVER OR OBSTRUCT ANY REFLECTIVE PORTION OF THE
ACHIEVE STABILITY OF THE BARRICADE. THE SANDBAGS SHALL BE PLACED
SANDBAGS SHALL BE USED WHEN SUPPLEMENTAL WEIGHTS ARE REQUIRED TO
SPECIFICATIONS FOR CONSTRUCTION.
SENSITIVE REFLECTIVE SHEETING ACCORDING TO THE CURRENT STANDARD
SIGNS, BARRICADES, AND PLASTIC DRUMS SHALL BE FACED WITH PRESSURE-
SHALL BE ORANGE IN COLOR AND EQUAL IN WIDTH.
THE HORIZONTAL REFLECTORIZED ORANGE AND WHITE STRIPES
STRIPE BEING ORANGE. NON REFLECTORIZED SPACES BETWEEN
ALTERNATING IN COLOR WITH THE TOPMOST REFLECTORIZED
STRIPES (2 ORANGE AND 2 WHITE) OF 6" UNIFORM WIDTH,
DRUMS SHALL HAVE AT LEAST 4 HORIZONTAL REFLECTORIZED
NOTE:
3 3 1/18/11
OF PLASTIC DRUMS FOR PLACEMENT OF TEMORARY CONCRETE BARRIER.
DIVIDED ROADWAY, AND R-126-SERIES FOR TYPICAL LOCATION AND SPACING
SEE ROAD STANDARD PLANS R-113-SERIES FOR TEMPORARY CROSSOVERS FOR
CONTRACT ON TYPE III BARRICADES.
SPECIFICATIONS FOR CONSTRUCTION AND ALL OTHER PROVISIONS IN THE
WARNING LIGHTS SHALL BE PLACED ACCORDING TO THE CURRENT STANDARD
HORIZONTAL BASE OF THE TYPE III BARICADE.
2" PERFORATED SQUARE STEEL TUBES MAY BE USED TO FABRICATE THE
(SPECIAL DETAIL)
SHEET
OF
| Untitled.pdf |
| US12_SkipPaving |
| US12_SkipPaving |
| WZD-125-E - 8in.pdf |
| wzd-125-e |
| wzd-125-e1 |
| wzd-125-e2 |
File details come from the government source that posted it. Updated .