202203726-C EMGS.pdf
PDF 1 MB Posted
- Solicitation number
- W9124A22R0015
About this file
This document contains a federal contract solicitation and related technical specifications for asbestos analysis services. The Army is seeking a contractor to conduct polarized light microscope analysis on 20 bulk samples to identify asbestos content according to EPA methods. The analysis will involve dissecting and examining each sample layer under different microscope magnifications to identify and quantify any asbestos fibers. Results will be reported separately for each layer to satisfy all regulatory requirements. The selected contractor must have the necessary equipment, facilities, and trained personnel to perform this specialized testing by the required deadlines.
A related opportunity involves awarding a firm fixed-price contract to construct sprinkler systems at two buildings at Fort Huachuca in Arizona. The work is a 100% small business set-aside under NAICS code 238220. The applicable wage determination is included, and bonds are required within 10 days of award. Proposals are due by August 12, 2022 at 4:00pm local time. The Army Contracting Command at Aberdeen Proving Ground will award this contract.
View the file
Other files
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Client Job: 1-11157111 PO Number: 41420
JobNumber: 202203726
Routing Number: -
# Samples: 20
PLMn
PLM The "New" Method; see below
Client:
Polarized Light Microscope (PLM) Analysis for Asbestos in Bulk Sample
Method and Analysis Information:
Each bulk sample is first dissected under a 7-30x magnification stereo-microscope. This examination is used to determine the general type of sample, how many and what type of layers it has, and initial estimates of fiber types and quantities. Second, liquid media mounts are made of each layer -such mounts may be of selected fibers (used solely for identification purposes) or may be representative of the layer as a whole (used for quantitation purposes). The mounts may be made in a synthetic Canadian balsam, one of several solvents, or in refractive index oils (media of known refractive index). Generally, a variety of different mounts are made: some optimized for fiber visibility, some optimized for fiber identification, and some optimized for fiber quantitation. The mounted slides are then examined at 50-400x magnification on a Nikon Labphot-pol microscope. Optical characteristics are used to identify each observed fiber type; the optical data are contained for each sample on its detail analysis sheet, attached.
Current EPA and NESHAP regulations designate a result of ≤1 % asbestos as "negative" or "non-regulated"and >1 % asbestos as "positive" or "regulated." Samples containing layers that have been determined to be "positive" may have to be handled differently during a renovation or demolition than samples whose layers have been determined to be "negative." OSHA under CFR 1926.1101 regulates work done involving any detectable concentration of asbestos.
The method of fiber identification and quantitation is the “Standard Operating Procedures for the Analysis of Asbestos in Bulk Samples using Polarized Light Microscopy”, Chapter 7 of the Quality Assurance and Management Manual. This SOP and its associated reporting have been designed to satisfy all requirements in both EPA Method 600/M4-82-020 (The Interim Method) and EPA Method 600/R-93/116 (The New Method). The Interim Method is the required method for AHERA (US EPA 40 CFR Pt. 763), but this method calls for the reporting of composited results of multi-layered samples that is no longer an acceptable reporting practice in most circumstances. Current EPA rules, such as NESHAP (US EPA 40 CFR Pt. 61), as well as NVLAP accreditation policies, call for separate reporting for each layer of multi-layered samples. The New Method contains the same procedures for identification and quantification of asbestos as does the Interim Method, except that multi-layered samples are reported to comply with the latest US EPA rule. Fiberquant not only reports the asbestos content of each layer of multi-layered samples separately (satisfying current EPA and NVLAP reporting requirements), but Fiberquant also reports what percentage of the sample each layer comprises. Therefore, the results may be arithmetically composited to satisfy the reporting requirements of the Interim Method. The method of fiber quantitation is an estimation technique in which the analysts quantitation is routinely calibrated by reference quantitation standards, and which has been shown to be equivalent in precision and accuracy to point counting. Friability is estimated for the purposes of deciding when to point count. Friabilities determined in the field take precedence over those determined in the laboratory. Those sample layers which are friable and estimated by the analyst to contain <= 1% asbestos are point counted using 400 points. Such point counting is required by NESHAP (National Emission Standards for Hazardous Air Polutants, Nov. 1990) in order to rely on analytical results that are ≤ 1%. The coefficient of variation for the estimation quantitation technique is 100% in the range 0-5%.
This means that PLM analysis is not capable of conclusively determining whether a layer containing close to 1% asbestos is actually "positive" or "negative". For this reason, Fiberquant refers to results where asbestos was detected but ≤ 1% as "borderline negative", and results where asbestos was >1 % but <= 2% as "borderline positive" to indicate the uncertainty in assigning a "positive" or "negative" label. In the sample summary, "ND" means that no asbestos was detected during the analysis. A "Tr" or "Trace" of asbestos reported is defined for our purposes as the detection of several asbestos fibers during the analysis; this level would be right at the limit of detection for the method. Trace is only reported on the analysis detail - in the summary a trace would be reported as <=1%. The limit of detection (the smallest % of asbestos that can be detected) varies greatly depending on the matrix in which the asbestos is found. As little as 0.001% asbestos can be detected in favorable samples, while detection in unfavorable samples may approach the detection limit of 1% stated in the method. During the analysis, the analyst, for Fiberquant identification purposes only, determines the "apparent sample type" and "apparent layer types." It must be emphasized that these types are only what is apparent. Often, different materials appear similar or identical after sampling, so the analyst may assign a type other than what was sampled.
Floor tiles present a special problem for PLM asbestos analysis. Floor tile can contain chrysotile fibers so thin that they cannot be resolved by optical methods. In such a case, we may observe a percentage of asbestos which is lower than the actual percentage, or not observe asbestos at all when some is present. For this reason, floor tiles reported as negative should be confirmed to be negative using transmission electron microscope (TEM) analysis. Likewise, vermiculite insulation materials containing traces of asbestiform asbestos present a problem for routine PLM analysis - the amphiboles are sometimes present in trace amounts inhomogeneously distributed. For this reason, loose vermiculite samples reported as negative should be confirmed to contain no amphibole using hydroseparation techniques.
The samples were analyzed under the following ongoing quality assurance program: Blank samples are routinely analyzed to maintain contamination-free materials. Each analyst has at least a bachelor's degree in physical science, and has also completed extensive training specific to asbestos analysis for 1-3 months before being allowed to analyze client samples. Qualitative reference samples are routinely analyzed to assure that analysts
Method: EPA 600/R-93/116Rec: 4/29/2022
Report Date: 5/6/2022 Date Analyzed: 5/6/2022
Fiberquant Internal SOP:
FACILITY SERVICES MANAGEMENT
CLARKSTON RD BLDG 30033
FT HUACHUCA, AZ
Office Phone: (520) 533-5906
FAX:
85613-0000
5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558
Fiberquant, Inc. Page 1 of 13
PLM Analysis Summary: Job Number: 202203726 1-11157111 can identify asbestos and asbestos-look-alike fibers. Quantitative reference samples are routinely analyzed to calibrate and characterize the estimation procedure. Microscope alignment is checked each day. Refractive index oils are calibrated at least quarterly. At least 10% of client samples are re-analyzed from scratch by a different analyst than the original, and any discrepancies are resolved for the sample and similar sample types before the results are reported. All quality checks performed for these samples were in control except as detailed in the "Analytical Notes" below. All analysts participate in interlab round robins and proficiency testing to assure competence. Fiberquant is accredited by NVLAP (Lab code #101031) for the analysis of bulk samples for asbestos using PLM. Accreditation does not imply endorsement by the EPA, any other United States governmental agency or any private agency or association. Each lab analysis refers only to the sample tested, and may not, due to the sampling process, be representative of the material sampled. This report may not be reproduced except in full, without the approval of Fiberquant Analytical Services.
Job Analysis Notes:
Some results may have been calculated using client supplied data, such as volume or area sampled, for which Fiberquant assumes no liability for accuracy.
Sample Number Lab Number Apparent Sample Type * Asbestos Detected Yes or No
Layer Color Apparent Layer Type * Asbestos Results
Wall System2022-03726- 141420-1-01 Asbestos Detected? NoSample # no asbestos detectedpaintvariousLayer # 1 no asbestos detectedplastertanLayer # 2
Acoustical Tile2022-03726- 241420-1-02 Asbestos Detected? NoSample # no asbestos detectedpaintwhiteLayer # 1 no asbestos detectedacoustical tileoff-whiteLayer # 2
Insulation2022-03726- 341420-1-03 Asbestos Detected? NoSample # no asbestos detectedinsulation wrapsilverLayer # 1 no asbestos detectedmasticclearLayer # 2
Insulation2022-03726- 441420-1-04 Asbestos Detected? NoSample # no asbestos detectedpaintoff-whiteLayer # 1 no asbestos detectedcoatingwhiteLayer # 2 no asbestos detectedinsulation wrapsilverLayer # 3 no asbestos detectedinsulationyellowLayer # 4
Wall System2022-03726- 541420-1-05 Asbestos Detected? NoSample # no asbestos detectedpaintoff-whiteLayer # 1 no asbestos detectedtexture/joint compoundwhiteLayer # 2 no asbestos detectedpaper/cardboardoff-whiteLayer # 3 no asbestos detectedtexture/joint compoundwhiteLayer # 4 no asbestos detectedpaper/cardboardtanLayer # 5 no asbestos detecteddrywall corewhiteLayer # 6
Wall System2022-03726- 641420-1-06 Asbestos Detected? NoSample # no asbestos detectedpaintvariousLayer # 1 no asbestos detectedplastertanLayer # 2
Acoustical Tile2022-03726- 741420-1-07 Asbestos Detected? NoSample # no asbestos detectedpaintwhiteLayer # 1 no asbestos detectedacoustical tileoff-whiteLayer # 2
Insulation2022-03726- 841420-1-08 Asbestos Detected? NoSample # no asbestos detectedcoatingwhiteLayer # 1 no asbestos detectedinsulation wrapsilverLayer # 2 no asbestos detectedmasticclearLayer # 3
Wall System2022-03726- 941420-1-09 Asbestos Detected? NoSample # no asbestos detectedpaintvariousLayer # 1 no asbestos detectedplastertanLayer # 2 no asbestos detectedpaintwhiteLayer # 3 no asbestos detectedplastertanLayer # 4
Insulation2022-03726- 1041420-1-10 Asbestos Detected? NoSample # no asbestos detectedinsulation wrapsilverLayer # 1 no asbestos detectedmasticclearLayer # 2 no asbestos detectedinsulationoff-whiteLayer # 3
Wall System2022-03726- 1141420-1-11 Asbestos Detected? NoSample # no asbestos detectedpaintoff-whiteLayer # 1 no asbestos detectedtexture/joint compoundwhiteLayer # 2 no asbestos detectedpaper/cardboardoff-whiteLayer # 3 no asbestos detectedtexture/joint compoundwhiteLayer # 4 no asbestos detectedpaper/cardboardtanLayer # 5 no asbestos detecteddrywall corewhiteLayer # 6
Acoustical Tile2022-03726- 1241420-1-12 Asbestos Detected? NoSample # no asbestos detectedpaintwhiteLayer # 1 no asbestos detectedacoustical tileoff-whiteLayer # 2
5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558
Fiberquant, Inc. Page 2 of 13
Wall System2022-03726- 1341420-1-13 Asbestos Detected? NoSample # no asbestos detectedpaintoff-whiteLayer # 1 no asbestos detectedtexture/joint compoundwhiteLayer # 2 no asbestos detectedpaintvariousLayer # 3 no asbestos detectedplastertanLayer # 4
Wall System2022-03726- 1441420-1-14 Asbestos Detected? NoSample # no asbestos detectedpaintvariousLayer # 1 no asbestos detectedplastertanLayer # 2
Acoustical Tile2022-03726- 1541420-2-15 Asbestos Detected? NoSample # no asbestos detectedpaintwhiteLayer # 1 no asbestos detectedacoustical tileoff-whiteLayer # 2
Ceiling System2022-03726- 1641420-2-16 Asbestos Detected? NoSample # no asbestos detectedpaintoff-whiteLayer # 1 no asbestos detectedacoustical tileoff-whiteLayer # 2 no asbestos detectedsurfacewhiteLayer # 3 no asbestos detectedpaper/cardboardtanLayer # 4 no asbestos detecteddrywall corewhiteLayer # 5
Insulation2022-03726- 1741420-2-17 Asbestos Detected? NoSample # no asbestos detectedcoatingwhiteLayer # 1 no asbestos detectedinsulation wrapwhiteLayer # 2
Wall System2022-03726- 1841420-2-18 Asbestos Detected? NoSample # no asbestos detectedpaintoff-whiteLayer # 1 no asbestos detectedpaper/cardboardtanLayer # 2 no asbestos detecteddrywall corewhiteLayer # 3
Acoustical Tile2022-03726- 1941420-2-19 Asbestos Detected? NoSample # no asbestos detectedpaintwhiteLayer # 1 no asbestos detectedacoustical tileoff-whiteLayer # 2
Wall System2022-03726- 2041420-2-20 Asbestos Detected? NoSample # no asbestos detectedpaintvariousLayer # 1 no asbestos detectedplastertanLayer # 2
* Apparent Sample Types and Apparent Layer Types are as they appeared to the analyst. Since many types of materials appear similar after sampling damage, the apparent type of material may not be the actual type of material.
5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558
Fiberquant, Inc. Page 3 of 13
PLM Analysis Details Job Number: 202203726 1-11157111
2022-03726- 141420-1-01 4/25/2022Lab Number Sample Sampled:
RAMAnalyzed By 5/6/2022
Homogeneous Wall System
No Non-fibrous SolidOKAn?
2# Layers NoAsbestos Detected?
Apparent Smp Type none Fiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of paint matrix using solvent. Procedure: dissolution of plaster matrix using acid.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations none
Non-Fibrous Components (in approx. decreasing order): powder, rock, polymer
Condition: acceptable
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 5 n.d. - - - - -paint various 1 2 95 n.d. - - - - -plaster tan 2
100Total % n.d. - - - - -Overall %
2022-03726- 241420-1-02 4/25/2022Lab Number Sample Sampled:
RAMAnalyzed By 5/6/2022
Homogeneous Acoustical Tile
No Fibrous MatOKAn?
2# Layers NoAsbestos Detected?
Apparent Smp Type cellulose fiber glass fiberFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of paint matrix using solvent. Procedure: dissolution of acoustical tile using acid.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations cellulose fiber glass fiber
W F N N H + U
CL D Y
Non-Fibrous Components (in approx. decreasing order): perlite, powder, binder
Condition: acceptable
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 2 n.d. n.d. - - - -paint white 1 2 98 20-30% 5-10% - - - -acoustical tile off-white 3
100Total % 20-30% 5-10% - - - -Overall %
2022-03726- 341420-1-03 4/25/2022Lab Number Sample Sampled:
RAMAnalyzed By 5/6/2022
Homogeneous Insulation
No Fibrous MatOKAn?
2# Layers NoAsbestos Detected?
Apparent Smp Type cellulose fiber glass fiberFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of matrix using solvent.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations cellulose fiber glass fiber
W F N N H + U
CL D Y
Non-Fibrous Components (in approx. decreasing order): metal, binder, Condition: acceptable
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 95 40-50% 10-20% - - - -insulation wrap silver 2 2 5 n.d. n.d. - - - -mastic clear 1
100Total % 40-50% 10-20% - - - -Overall %
5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558
Fiberquant, Inc. Page 4 of 13
2022-03726- 441420-1-04 4/25/2022Lab Number Sample Sampled:
RAMAnalyzed By 5/6/2022
Homogeneous Insulation
No Fibrous MatOKAn?
4# Layers NoAsbestos Detected?
Apparent Smp Type cellulose fiber glass fiberFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of matrix using solvent.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations cellulose fiber glass fiber
W F N N H + U
CL D Y
Non-Fibrous Components (in approx. decreasing order): metal, binder, filler
Condition: acceptable
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 1 n.d. n.d. - - - -paint off-white 1 2 9 n.d. n.d. - - - -coating white 1 3 45 40-50% 10-20% - - - -insulation wrap silver 2 4 45 <=1% 90-100% - - - -insulation yellow 3
100Total % 20-30% 40-50% - - - -Overall %
2022-03726- 541420-1-05 4/25/2022Lab Number Sample Sampled:
RAMAnalyzed By 5/6/2022
Homogeneous Wall System
No Fibrous SolidOKAn?
6# Layers NoAsbestos Detected?
Apparent Smp Type cellulose fiber glass fiberFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of paint matrix using solvent. Procedure: dissolution of joint compound/texture matrix using acid.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations cellulose fiber glass fiber
W F N N H + U
CL D Y
Non-Fibrous Components (in approx. decreasing order): powder, binder, Condition: acceptable
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 1 n.d. n.d. - - - -paint off-white 1 2 4 n.d. n.d. - - - -texture/joint compound white 3 3 3 90-100% n.d. - - - -paper/cardboard off-white 2 4 2 n.d. n.d. - - - -texture/joint compound white 3 5 5 90-100% n.d. - - - -paper/cardboard tan 2 6 85 <=1% <=1% - - - -drywall core white 3
100Total % 5-10% <=1% - - - -Overall %
5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558
Fiberquant, Inc. Page 5 of 13
2022-03726- 641420-1-06 4/25/2022Lab Number Sample Sampled:
RAMAnalyzed By 5/6/2022
Homogeneous Wall System
No Fibrous SolidOKAn?
2# Layers NoAsbestos Detected?
Apparent Smp Type cellulose fiber Fiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of paint matrix using solvent. Procedure: dissolution of plaster matrix using acid.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations cellulose fiber
W F N N H + U
Condition: acceptable
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 5 n.d. - - - - -paint various 1 2 95 <=1% - - - - -plaster tan 2
100Total % <=1% - - - - -Overall %
2022-03726- 741420-1-07 4/25/2022Lab Number Sample Sampled:
RAMAnalyzed By 5/6/2022
Homogeneous Acoustical Tile
No Fibrous MatOKAn?
2# Layers NoAsbestos Detected?
Apparent Smp Type cellulose fiber glass fiberFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of paint matrix using solvent. Procedure: dissolution of acoustical tile using acid.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations cellulose fiber glass fiber
W F N N H + U
CL D Y
Non-Fibrous Components (in approx. decreasing order): perlite, powder, binder
Condition: acceptable
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 2 n.d. n.d. - - - -paint white 1 2 98 20-30% 5-10% - - - -acoustical tile off-white 3
100Total % 20-30% 5-10% - - - -Overall %
5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558
Fiberquant, Inc. Page 6 of 13
2022-03726- 841420-1-08 4/25/2022Lab Number Sample Sampled:
RAMAnalyzed By 5/6/2022
Homogeneous Insulation
No Fibrous MatOKAn?
3# Layers NoAsbestos Detected?
Apparent Smp Type cellulose fiber glass fiberFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of matrix using solvent.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations cellulose fiber glass fiber
W F N N H + U
CL D Y
Non-Fibrous Components (in approx. decreasing order): binder, filler, metal
Condition: acceptable
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 40 n.d. n.d. - - - -coating white 1 2 58 40-50% 10-20% - - - -insulation wrap silver 2 3 2 <=1% n.d. - - - -mastic clear 1
100Total % 20-30% 5-10% - - - -Overall %
2022-03726- 941420-1-09 4/25/2022Lab Number Sample Sampled:
RAMAnalyzed By 5/6/2022
Homogeneous Wall System
No Non-fibrous SolidOKAn?
4# Layers NoAsbestos Detected?
Apparent Smp Type none Fiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of paint matrix using solvent. Procedure: dissolution of plaster matrix using acid.
Note: there appears to be more than one sample layer sequence in the bag (e.g., samples from more than one location); therefore, the reported layer sequence has been estimated/composited.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 5 n.d. - - - - -paint various 1 2 35 n.d. - - - - -plaster tan 2 3 2 n.d. - - - - -paint white 1 4 58 n.d. - - - - -plaster tan 2
100Total % n.d. - - - - -Overall %
5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558
Fiberquant, Inc. Page 7 of 13
2022-03726- 1041420-1-10 4/25/2022Lab Number Sample Sampled:
RAMAnalyzed By 5/6/2022
Homogeneous Insulation
No Fibrous MatOKAn?
3# Layers NoAsbestos Detected?
Apparent Smp Type cellulose fiber glass fiberFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of matrix using solvent. Procedure: dissolution of matrix using dilute HCl acid.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations cellulose fiber glass fiber
W F N N H + U
CL D Y
Non-Fibrous Components (in approx. decreasing order): binder, filler, metal
Condition: acceptable
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 60 40-50% 10-20% - - - -insulation wrap silver 2 2 15 n.d. n.d. - - - -mastic clear 1 3 25 <=1% 90-100% - - - -insulation off-white 3
100Total % 20-30% 30-40% - - - -Overall %
2022-03726- 1141420-1-11 4/25/2022Lab Number Sample Sampled:
RAMAnalyzed By 5/6/2022
Homogeneous Wall System
No Fibrous SolidOKAn?
6# Layers NoAsbestos Detected?
Apparent Smp Type cellulose fiber glass fiberFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of paint matrix using solvent. Procedure: dissolution of joint compound/texture matrix using acid.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations cellulose fiber glass fiber
W F N N H + U
CL D Y
Non-Fibrous Components (in approx. decreasing order): powder, binder, Condition: acceptable
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 2 n.d. n.d. - - - -paint off-white 1 2 3 n.d. n.d. - - - -texture/joint compound white 3 3 3 90-100% n.d. - - - -paper/cardboard off-white 2 4 37 n.d. n.d. - - - -texture/joint compound white 3 5 5 90-100% n.d. - - - -paper/cardboard tan 2 6 50 <=1% <=1% - - - -drywall core white 3
100Total % 5-10% <=1% - - - -Overall %
5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558
Fiberquant, Inc. Page 8 of 13
2022-03726- 1241420-1-12 4/25/2022Lab Number Sample Sampled:
RAMAnalyzed By 5/6/2022
Homogeneous Acoustical Tile
No Fibrous MatOKAn?
2# Layers NoAsbestos Detected?
Apparent Smp Type cellulose fiber glass fiberFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of paint matrix using solvent. Procedure: dissolution of acoustical tile using acid.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations cellulose fiber glass fiber
W F N N H + U
CL D Y
Non-Fibrous Components (in approx. decreasing order): perlite, powder, binder
Condition: acceptable
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 2 n.d. n.d. - - - -paint white 1 2 98 20-30% 5-10% - - - -acoustical tile off-white 3
100Total % 20-30% 5-10% - - - -Overall %
2022-03726- 1341420-1-13 4/25/2022Lab Number Sample Sampled:
RAMAnalyzed By 5/6/2022
Homogeneous Wall System
No Non-fibrous SolidOKAn?
4# Layers NoAsbestos Detected?
Apparent Smp Type none Fiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of paint matrix using solvent. Procedure: dissolution of plaster matrix using acid.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 2 n.d. - - - - -paint off-white 1 2 3 n.d. - - - - -texture/joint compound white 3 3 5 n.d. - - - - -paint various 1 4 90 n.d. - - - - -plaster tan 2
100Total % n.d. - - - - -Overall %
5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558
Fiberquant, Inc. Page 9 of 13
2022-03726- 1441420-1-14 4/25/2022Lab Number Sample Sampled:
RAMAnalyzed By 5/6/2022
Homogeneous Wall System
No Non-fibrous SolidOKAn?
2# Layers NoAsbestos Detected?
Apparent Smp Type none Fiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of paint matrix using solvent. Procedure: dissolution of plaster matrix using acid.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 5 n.d. - - - - -paint various 1 2 95 n.d. - - - - -plaster tan 2
100Total % n.d. - - - - -Overall %
2022-03726- 1541420-2-15 4/25/2022Lab Number Sample Sampled:
RAMAnalyzed By 5/6/2022
Homogeneous Acoustical Tile
No Fibrous MatOKAn?
2# Layers NoAsbestos Detected?
Apparent Smp Type cellulose fiber glass fiberFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of paint matrix using solvent. Procedure: dissolution of acoustical tile using acid.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations cellulose fiber glass fiber
W F N N H + U
CL D Y
Non-Fibrous Components (in approx. decreasing order): perlite, powder, binder
Condition: acceptable
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 2 n.d. n.d. - - - -paint white 1 2 98 20-30% 5-10% - - - -acoustical tile off-white 3
5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558
Fiberquant, Inc. Page 10 of 13
2022-03726- 1641420-2-16 4/25/2022Lab Number Sample Sampled:
RAMAnalyzed By 5/6/2022
Homogeneous Ceiling System
No Fibrous MatOKAn?
5# Layers NoAsbestos Detected?
Apparent Smp Type cellulose fiber glass fiberFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of paint matrix using solvent. Procedure: dissolution of acoustical tile using acid.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations cellulose fiber glass fiber
W F N N H + U
CL D Y
Non-Fibrous Components (in approx. decreasing order): perlite, powder, binder
Condition: acceptable
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 1 n.d. n.d. - - - -paint off-white 1 2 29 20-30% 5-10% - - - -acoustical tile off-white 3 3 3 n.d. n.d. - - - -surface white 1 4 5 90-100% n.d. - - - -paper/cardboard tan 2 5 62 <=1% n.d. - - - -drywall core white 3
100Total % 10-20% 2-5% - - - -Overall %
2022-03726- 1741420-2-17 4/25/2022Lab Number Sample Sampled:
RAMAnalyzed By 5/6/2022
Homogeneous Insulation
No Fibrous MatOKAn?
2# Layers NoAsbestos Detected?
Apparent Smp Type cellulose fiber glass fiberFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of matrix using solvent.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations cellulose fiber glass fiber
W F N N H + U
CL D Y
Non-Fibrous Components (in approx. decreasing order): binder, filler, metal
Condition: acceptable
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 50 n.d. n.d. - - - -coating white 1 2 50 40-50% 10-20% - - - -insulation wrap white 2
5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558
Fiberquant, Inc. Page 11 of 13
2022-03726- 1841420-2-18 4/25/2022Lab Number Sample Sampled:
RAMAnalyzed By 5/6/2022
Homogeneous Wall System
No Fibrous SolidOKAn?
3# Layers NoAsbestos Detected?
Apparent Smp Type cellulose fiber Fiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of matrix using solvent. No texture.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations cellulose fiber
W F N N H + U
Non-Fibrous Components (in approx. decreasing order): powder, binder, Condition: acceptable
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 2 n.d. - - - - -paint off-white 1 2 8 90-100% - - - - -paper/cardboard tan 2 3 90 >1-2% - - - - -drywall core white 3
100Total % 5-10% - - - - -Overall %
2022-03726- 1941420-2-19 4/25/2022Lab Number Sample Sampled:
RAMAnalyzed By 5/6/2022
Homogeneous Acoustical Tile
No Fibrous MatOKAn?
2# Layers NoAsbestos Detected?
Apparent Smp Type glass fiber cellulose fiberFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of paint matrix using solvent. Procedure: dissolution of acoustical tile using acid.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations glass fiber cellulose fiber
CL D Y
W F N N H + U
Non-Fibrous Components (in approx. decreasing order): glass, binder, filler
Condition: acceptable
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 2 n.d. n.d. - - - -paint white 1 2 98 60-70% <=1% - - - -acoustical tile off-white 3
100Total % 60-70% <=1% - - - -Overall %
5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558
Fiberquant, Inc. Page 12 of 13
2022-03726- 2041420-2-20 4/25/2022Lab Number Sample Sampled:
RAMAnalyzed By 5/6/2022
Homogeneous Wall System
No Non-fibrous SolidOKAn?
2# Layers NoAsbestos Detected?
Apparent Smp Type none Fiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of paint matrix using solvent. Procedure: dissolution of plaster matrix using acid.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 5 n.d. - - - - -paint various 1 2 95 n.d. - - - - -plaster tan 2
100Total % n.d. - - - - -Overall %
Fr=Friability: 1=very non-friable; 2= non-friable; 3=friable; 4=highly friable Colors: B=black;BL=blue;BR=brown;CL=clear;G=Green;GY=gray;OR=orange;OW=off-white;PN=pink;PU=purple;R=red;TN=tan;W=white;Y=yellow;V=various Fiber Morphology: A=fine fibers/bundles, white, sinewy, flexible; B=fine fibers/bundles, w-br, straight, broomed ends; C=fine fibers/bundles, blue, straight, broomed ends;
D=fine to coarse fibers, CL-B, brittle; E=coarse fibers,CL or dyed, striated; F=coarse fibers or splinters, W-BR, ribbon-like; G=lath-like or shards, low aspect ratio, may taper Iso=isotropism - may be yes or no; Pleo=pleochroism - may be yes or no; Bi=birefringence - may be None, Low, Medium or High Elg=sign of elongation - may be +, - or B (both); Ext=extinction - may be Parallel, Oblique, None or Undulating; Oil=medium used to for dispersion staining Col Par=dispersion staining colors parallel to the fiber (fiber/halo): b/w=black/white; dg/py=dark gray/pale yellow; vg/y=violet gray/yellow; db/ly=dark blue/lemon yellow; vb/g= vivid blue/gold; sb/o=sky blue/orange; pb/r=pale blue/red; gb/dr=gray blue/dark red; w/b=white/black. Col Perp=same only perpendicular to fiber.
RI Par=refractive index parallel to fiber; RI Perp=refractive index perpendicular to fiber
06-May-22Analyst: ROBERT A. McCORMICK
Larry S. Pierce, Approved Accreditation Signatory
Printed:
06-May-22Original Print Date:
5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558
Fiberquant, Inc. Page 13 of 13
File details come from the government source that posted it. Updated .