UP
VESTIBULE
EXAM
CONSULT
CONSULT
CONSULT
CONSULT
EXAM
CONSULT
CONSULT
CONSULT
PAD
CORR
EKG EXAM
IMR
IMR
IMR
IMR
IMR
IMR
BIOHAZ
CLOSET
TOILET
CONSULT
AUDIO
LAB
WORKROOM
RECEP
EXAM 4
EXAM 3
EXAM 2
EXAM 1
PANO 1
PANO 2
CONSULT
RECORDS
CONSULT
TECHS
CONSULT
168CONSULT
UNIT SUPPLY
VAULT
M LATRINE
W LATRINE
M SHOWER
W SHOWER
COMM
FITNESS RM
PROVIDER
WAIT
WAIT
WAIT
WAIT
WAIT
DENTAL
WAIT
BH WAIT
CORR
BREAK
OFFICE
OFFICE
OFFICE
OPEN MOC
OFFICE
CORR
(EXISTING)
CORR
(EXISTING)
VEST
(EXISTING)
ELEV EQUIP
(EXISTING)
ELEV
(EXISTING)
STAIR
(EXISTING)
MENS
(EXISTING)
WOMENS
(EXISTING)
STAIR
(EXISTING)
OFFICE
OFFICE
CONSULT
CLOSET
CPT-1LVT-1
C P
T -1
C P
T -1
LV
T
-1
LV
T
-1
(EXISTING)
(EXISTING)
C P
T -1
LV
T
-1
SEALED
CONC
SEALED
CONC
WALKOFF
CPT
WT-1 WT-1 WT-1 WT-1
WT-1WT-1
S1
S1 S1 S1
S1 S1 S1
S4
S2S2
S4 S4
S2
S2
S3
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1S1
S1
S1
S1
S1
S1
S1S1
S1
S1
S1
S1
S1
S1
S1 S1
S1
WT-1WT-1 WT-1 WT-1
9' - 3 5/8" 9' - 3 5/8" 9' - 3 5/8" 7' - 4 1/2" 1' - 11"
9'
/2
8' - 4 1/4"
7'
3/ 8"
7'
3/ 8"
7'
3/ 8"
7'
/8
2'
3/ 8"
7'
/2
8' - 4 1/8" 8' - 4 1/8" 8' - 4 1/8" 8' - 4 1/8" 8' - 11 1/4" 8' - 11 1/4" 8' - 11 1/4"
CONTROL
JOINTS, TYP
4' - 5 5/8" 4' - 5 5/8" 4' - 5 5/8" 4' - 5 5/8" 4' - 0 1/4" 4' - 0 1/4"
S2
CMT-2
FD FD
UPDATE EXTENT OF
EXISTING FLOOR
SAFETY PAINT TO
MAINTAIN REQUIRED
EQUIP CLEARANCE
(4'-0" TYP)
CG-1
TYP.
P-3
P-3
P-4
P-4
P-4
P-1 S1
PT-2
PT-2
P-4
P R
O T
E C
T E
X
IS
T
IN
G B
R
IC
K E
X T
E R
IO
R
T O
R E
M A
IN
PROVIDE SSM-3 INTERIOR SILL
AT EXIST AND NEW WINDOWS,
TYP (SIM DETAIL A3/AE501)
POLISH AND BLEND EXIST CONC
FLOORING FINISH AS NEEDED
TO CARRY CORRIDOR FINISH
1. REFER TO FINISH PLANS, ELEVATIONS, REFLECTED CEILING PLANS, AND/OR
DETAILS FOR EXTENTS OF CHANGES IN FINISHES.
2. FLOORING TRANSITIONS BETWEEN ROOMS SHALL BE AT CENTERLINE OF DOOR,
UNO. SEE SHEET AE451 FOR FLOORING TRANSITION DETAILS.
3. ALL EXPOSED TILE EDGES TO BE FINISHED WITH ANODIZED ALUMINUM "L" SHAPED
METAL TRANSITION STRIP, UNO.
4. SEE FINISH PLANS PLANS FOR LOCATIONS OF ROLLER SHADES (WT-1) AND
INSTALL WITHIN WINDOW FRAME PER MFR RECOMMENDATIONS.
5. DO NOT PAINT OUTLET OR SWITCH COVERS.
6. ALL WINDOW SILLS TO BE SOLID SURFACE MATERIAL SSM-3, UNO.
7. ALL SOLID SURFACE OUTSIDE CORNERS TO BE MITERED, UNO.
8. CRACK-ISOLATION AND WATERPROOFING MEMBRANE MEETING ANSI A118.12 FOR
ALL FLOORS WHERE WATER IS PRESENT TO BE PROVIDED 12" MIN. PAST THE
ROOM EXTENTS (INCLUDING UNDER THE WALL MEMBRANE) AND/OR PER
MANUFACTURER'S INSTALLATION INSTRUCTIONS.
9. WATERPROOFING MEMBRANE MEETING ANSI A118.10 FOR ALL SHOWER WALLS TO
BE PROVIDED UP TO FULL HEIGHT AND MUST OVERLAP CRACK-ISOLATION AND
WATERPROOFING MEMBRANE ON THE FLOOR PER MANUFACTURER'S
INSTALLATION INSTRUCTIONS.
10. NOTE: CONTROL JOINTS SHOWN WHERE EXPOSED POLISHED CONCRETE IS
SCHEDULED. ALL OTHER AREAS NOT NOTED MUST MEET MINIMUM
REQUIREMENTS FOR CONTROL JOINTS.
11. ALL POLISHED CONCRETE TO BE COMPLETED PRIOR TO NON-STRUCTURAL
INTERIOR WALLS ARE ERECTED. THIS WILL ALLOW FOR A CONSISTANT FLOOR
FINISH MINIMIZING THE NEED FOR HAND POLISHING/GRINDING. AFTER
COMPLETION POLISHED CONCRETE FLOORS TO BE COVERED AND PROTECTED
DURING ENTIRE CONSTRUCTION.
12. ALL HOLLOW METAL DOORS AND FRAMES TO BE PAINTED, P-4 U.N.O.
13. PAINT ALL CEILING SOFFITS, P-1.
GENERAL FINISH NOTES
1. INSTALLATION SHALL MEET ALL REQUIREMENTS OF THE AMERICAN WITH
DISABILITIES ACT (ADA). ADA REQUIREMENT WILL OVERRULE PLAQUE DETAILS
SHOWN IF IN CONFLICT.
2. INSTALLATION SHALL MEET ALL LOCAL, STATE, FEDERAL BUILDING AND SAFETY
CODES.
3. ALL SIGNS SHALL BE INSTALLED LEVEL AND PLUMB AND AT A CONSISTANT
HEIGHT.
4. HANGING AND FLAG SIGNS MUST REMAIN 24" FROM SPRINKLER HEADS.
5. SIGNS CANNOT VISUALLY BLOCK ILLUMINATED "EXIT" SIGNS. EXIT SIGNS MUST BE
VISUALLY UNOBSTRUCTED FROM A DISTANCE OF 100 FEET.
6. LOCATIONS MAY VARY UP TO 1/2" LEFT OR RIGHT OF DESIGNATION UNLESS FIELD
CONDITIONS REQUIRE FURTHER MODIFICATION.
7. LOCATIONS UNABLE TO BE INSTALLED IN DESIGNATED AREAS TO BE RELOCATED
FOLLOWING REVIEW BY ARCHITECT, SIGN PLANNER OR DESIGNATED FACILITY
STAFF OR REPRESENTATIVE.
8. CLEAR SILICON ADHESIVE CAULK TO BE ADDED INSIDE TAPE AREA AT A MINIMUM
OF 2 LOCATIONS. NO SILICONE TO BE VISIBLE AROUND EDGES OF SIGN.
9. SIGNS UNABLE TO ACHIEVE ADA STANDARD LATCH POSITION CAN BE PLACED AT
HINGE LOCATION OR BE POSITIONED UP TO 2" FROM FRAME. CORNER LOCATIONS
CAN BE MODIFIED TO NEAREST INSIDE WALL AT KNOB SIDE OF FRAME. TACTILE
SIGNS SHOULD NOT BE PLACED ON DOOR AS AN ALTERNATIVE LOCATION UNLESS
DESIGNATED ON PLAN OR IN SCHEDULE.
10. HANGING SIGNS THAT OBSTRUCT "EXIT" SIGNS OR ARE NEAR SPRINKLER HEADS
CAN BE MODIFIED TO OPPOSITE SIDE OF DOOR OR HELD FURTHER OFF WALL
SURFACE.
11. WALL MOUNTED OVERHEAD SIGNS INDICATED AS CENTERED ON BULKHEADS CAN
BE MODIFIED LEFT OR RIGHT AS REQUIRED BY "EXIT" SIGNS OR OTHER
OBSTRUCTIONS.
12. DOOR TAG SIGNS ARE LOCATED AT ALL DOORS AND NOT SHOWN ON THE PLANS.
13. REFER TO SECTION 10 14 00 FOR ADDITIONAL INFORMATION.
14. SIGNAGE NAMES AND NUMBERING TO BE VERIFIED PRIOR TO FABRICATION BY
CONTRACTING OFFICER.
15. SEE SPECIFICATION SECTION 10 14 00 FOR FULL SIGNAGE SPECIFICATIONS.
GENERAL SIGNAGE NOTES
CPT-1
CONC-1
PT-1
LVT-1
RSF-1
SAFETY FLOOR PAINT
N
KEY PLAN
REVISIONS
FILE LOG
ACTIVITY
Draw
Design
Manager
Check
STAMP
Project No.
BY
A
B
C
D
P L A N N I N G
A R C H I T E C T U R E
E N G I N E E R I N G
I N T E R I O R S
EST. 1915
E
F
2 3 4 5 6 7
Copyright © 2018 LEO A DALY Company
/2
/2
:5
:4
P M
2400 NW 24th Street Lincoln, NE 68524
NEBRASKA ARMY
NATIONAL GUARD
FINISH SCHEDULE AND PLANS
IN101
PENTERMAN
READINESS CENTER
RENOVATION &
ADDITION
003-10205-007
April 9, 2020
BFH
DLH
LLS
CMR
la d c o \s h a re s \p ro je c ts
\0 \0
-1
-0
\4
-0 -P ro d u c ti o n -W o rk in g \4
-1 -B
IM
-C
A D
\R e v it P
R C
-0 -A rc h .r v t
CONSTRUCTION
DOCUMENTS
2433 NW 24th Street Lincoln, NE 68524
8600 Indian Hills Drive Omaha, NE 68114-4039 Tel 402.391.8111 Fax 402.391.8564
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
SCALE: 1/8" = 1'-0"
FINISH PLAN LEVEL 1
ROOM FINISH SCHEDULE
ROOM NO. ROOM NAME FLOOR BASE
WALLS
CEILING REMARKSNORTH EAST SOUTH WEST
141 OPEN MOC OFFICE CPT-1 RB-1 P-1 P-1 P-1 P-1 APC-1
142 OFFICE CPT-1 RB-1 P-1 P-1 P-1 P-1 APC-1
143 OFFICE CPT-1 RB-1 P-1 P-1 P-1 P-1 APC-1
144 OFFICE CPT-1 RB-1 P-1 P-1 P-1 P-1 APC-1
146 OFFICE CPT-1 RB-1 P-1 P-1 P-1 P-1 APC-1
147 OFFICE CPT-1 RB-1 P-1 P-1 P-1 P-1 APC-1
148 BREAK CONC-1 RB-1 P-1 P-1 P-1 P-1 APC-1
151 DENTAL WAIT CPT-1/LVT-1 RB-1 P-1 P-1/P-4 P-1/P-4 P-1 APC-1
152 RECORDS CPT-1 RB-1 P-1 P-1 P-1 P-1 APC-1
153 CLOSET LVT-1 RB-1 P-1 P-1 P-1 P-1 APC-1
154 CONSULT CPT-1 RB-1 P-1 P-1 P-1 P-1 APC-1
156 PANO 1 LVT-1 RB-1 P-2 P-2 P-2 P-2 APC-1
157 PANO 2 LVT-1 RB-1 P-2 P-2 P-2 P-2 APC-1
158 EXAM 1 LVT-1 RB-1 P-1 P-2 P-2 P-2 APC-1
159 EXAM 2 LVT-1 RB-1 P-2 P-2 P-2 P-2 APC-1
161 EXAM 3 LVT-1 RB-1 P-2 P-2 P-2 P-2 APC-1
162 EXAM 4 LVT-1 RB-1 P-4 P-2 P-2 P-2 APC-1
163 BH WAIT CPT-1 RB-1 P-1 P-1 P-1 P-1 APC-1
164 TECHS CPT-1 RB-1 P-1 P-1 P-1 P-1 APC-1
166 CONSULT CPT-1 RB-1 P-1 P-1 P-1 P-1 APC-1
167 CONSULT CPT-1 RB-1 P-1 P-1 P-1 P-1 APC-1
168 CONSULT CPT-1 RB-1 P-1 P-1 P-1 P-1 APC-1
169 UNIT SUPPLY EXST EXST P-1 P-1 P-1 P-1 EXST
171 VAULT EXST EXST -- -- -- -- EXST EXISTING FINISHES TO REMAIN
172 CORR CONC-1 RB-1 P-1 P-1 P-1/CMT-2 P-1 APC-1 PAINTED 8X8 SCORED CMU ON NORTH WALL TO MATCH EXISTING
173 COMM SEALED RB-1 P-1 P-1 P-1 P-1 EXPOSED
176 W SHOWER PT-1 PT-2 PT-2 PT-2 PT-2 PT-2 GWB/P-1
177 W LATRINE PT-1 PT-2 PT-2 PT-2 PT-2 PT-2 GWB/P-1
178 M LATRINE PT-1 PT-2 PT-2 PT-2 PT-2 PT-2 GWB/P-1
179 M SHOWER PT-1 PT-2 PT-2 PT-2 PT-2 PT-2 GWB/P-1
180 CLOSET SEALED RB-1 P-1 P-1 P-1 P-1 EXPOSED
181 FITNESS RM RSF-1 RB-1 P-3 P-1 P-1 EXP BRICK EXPOSED/P-1
ROOM FINISH SCHEDULE
ROOM NO. ROOM NAME FLOOR BASE
WALLS
CEILING REMARKSNORTH EAST SOUTH WEST
LEVEL 1
101 VESTIBULE WLKOFF CPT RB-1 P-1 P-1 P-1 P-1 APC-1
102 WAIT CONC-1 RB-1 P-1/P-5 P-1/P-5 P-1 P-1 APC-1
103 WAIT CPT-1 RB-1 P-1 P-1 P-1 P-1 APC-1
104 PAD CPT-1 RB-1 P-1 P-1 P-1 P-1 APC-1
105 CONSULT CPT-1 RB-1 P-1 P-1 P-1 P-1 APC-1
106 CONSULT CPT-1 RB-1 P-1 P-1 P-1 P-1 APC-1
107 CONSULT CPT-1 RB-1 P-1 P-1 P-1 P-1 APC-1
108 CONSULT CPT-1 RB-1 P-1 P-1 P-1 P-1 APC-1
109 PROVIDER WAIT CPT-1 RB-1 P-1 P-1 P-1 P-1 APC-1
111 CONSULT CPT-1 RB-1 P-1 P-1 P-1 P-1 APC-1
112 CONSULT CPT-1 RB-1 P-1 P-1 P-1 P-1 APC-1
113 CONSULT CPT-1 RB-1 P-1 P-1 P-1 P-1 APC-1
114 CONSULT CPT-1 RB-1 P-1 P-1 P-1 P-1 APC-1
116 EXAM LVT-1 RB-1 P-2 P-2 P-2 P-2 APC-1
117 EXAM LVT-1 RB-1 P-2 P-2 P-2 P-2 APC-1
121 WAIT CPT-1 RB-1 P-1 P-1 P-1 P-1 APC-1
122 AUDIO CPT-1 RB-1 P-1 P-1 P-1 P-1 APC-1
123 CONSULT CPT-1 RB-1 P-1 P-1 P-1 P-1 APC-1
124 WAIT CPT-1/LVT-1 RB-1 P-1 P-1 P-1 P-1 APC-1
126 RECEP CPT-1 RB-1 P-1 P-1 P-1 P-1 APC-1
127 IMR LVT-1 RB-1 P-2 P-2 P-2 P-2 APC-1
128 IMR LVT-1 RB-1 P-2 P-2 P-2 P-2 APC-1
129 IMR LVT-1 RB-1 P-2 P-2 P-2 P-2 APC-1
131 TOILET PT-1 PT-2 PT-2 PT-2 PT-2 PT-2 GWB/P-1
132 LAB WORKROOM LVT-1 RB-1 P-1 P-1 P-1 P-1 APC-1
133 IMR LVT-1 RB-1 P-2 P-2 P-2 P-2 APC-1
134 IMR LVT-1 RB-1 P-2 P-2 P-2 P-2 APC-1
135 IMR LVT-1 RB-1 P-2 P-2 P-2 P-2 APC-1
137 BIOHAZ SEALED RB-1 P-1 P-1 P-1 P-1 APC-1
138 EKG EXAM LVT-1 RB-1 P-2 P-2 P-2 P-2 APC-1
139 CORR EXG. RB-1 P-1 P-1 P-1 P-1 APC-1
NO. DESCRIPTION DATE
1 ASI No.1 08/17/2020
4'
SCALE : 1/8" = 1'-0"
0 8' 16'
FINISH KEY
DENTAL
IMR
AUDIO
BEHAVIORAL
HEALTH
S4
PROVIDER HEALTH
NURSE CASE MANAGEMENT
PATIENT ADMINISTRATION
S1A:PAD
S1B:NCM 2S1B:NCM 1 S1B:NCM 3
S1B:NCM 4
CONSULT 2
NOT NEEDED IN THIS
PROJECT
TYPE S1A SIGN
W/BLANK BACKPLATE
ON GLASS DOOR
TYPE S1A - NUMBER, NAME, BRAILLE
TYPE S1B - NUMBER, NAME, BRAILLE,
INTERCHANGEABLE SLOT
7.
in
2.
in
TYPE S2
TYPE S3
TYPE S4
S1D: RECORDS
RETURN
S1A: PATEIENT
ADMINISTRATION
S1A:PROVIDER
HEALTH
S1B: CONSULT 1
S1B: CONSULT 3
S1B: CONSULT 4 S1B: CONSULT 2
S1B:EXAM 2 S1B:EXAM 1
S1A:AUDIO CONSULT
TYPE S5
BIOHAZARD
S5
(ON DOOR)
S1A:EKG
S1A:IMR 1S1A:IMR 2S1A:IMR 3
S1A:IMR 6S1A:IMR 5S1A:IMR 4
S1A:LAB
S1A:IMR TOILET
S1B: CONSULT 1
S1B: CONSULT 2 S1B: CONSULT 3
PAPER SLOT
2.
in5.
in
TYPE S1C - NUMBER, BRAILLE,
INTERCHANCEABLE SLOT
S1C
S1C
S1C
S1C
S1C
S1A:CONSULT
S1A:RECORDS
S1A:EQUIPMENT
S1A:BEHAVIORAL
HEALTH
S1A:UNIT
SUPPLY
S1A:DENTAL
S1A:IMR
S1A:MEDICAL
OPERATIONS CENTER
S1A:PANO 2
S1A:PANO 1
S1A:EXAM 1
S1A:EXAM 2 S1A:EXAM 3
S1A:EXAM 4
TYPE S1D - NAME, BRAILLE
S1D: RECORDS
CHECK-OUT
S1D: RECORDS
RETURN
S1D: RECORDS
CHECK-OUT
S2
(ON DOOR)
S2
(ON DOOR)
S1A:COMM
S1A:ELEC
S1A:FITNESS
S4 S4
PAPER SLOT
S3
(ON DOOR)