2016-0111 180221 add 2 write up_Addendum#2.pdf

PDF 40 KB Posted

Attached to
Bond Bid Package II - Site Improvements and Cooling Tower
Solicitation number
RFP-GITS-180000001406-2
Issued by
Wayne County, Michigan

About this file

This is Addendum No. 2 for the Grosse Ile Township Schools Bid Pack 2 project, which includes site improvements at both Meridian Elementary School and Grosse Ile High School in Grosse Ile, Michigan (Project No. 2016-011.1 and 2016-013.1). The addendum, issued on February 28, 2018, announces a pre-bid meeting scheduled for March 5, 2018, at 3:00 PM at Grosse Ile High School's main entrance lobby, and extends the bid due date to March 12, 2018, at 12:00 PM. The project scope includes cooling tower work at the high school with requirements for insulated condenser water piping above and below the roof line, and site concrete work at Meridian Elementary.

The addendum provides several specification changes, including clarifications regarding earthwork sections (32 2000 not applicable to athletics scope, 32 2001 applicable to athletics scope) and modifications to the Plant Mix Bituminous Asphalt Pavement specifications for the track. Drawing changes include corrections to Sheet C1.3's graphic scale, addition of new soil erosion and sedimentation control plans and details (Sheets L1.00 and LD1.03), removal of the base bid line from Proposal C: Fencing, and updates to the cooling tower control sequence to indicate the existing JCI Niagara system.

View the file

Other files

File Type Posted
Grosse Ile BP 2 add 1 write-up.pdf PDF
Advertisement for bid BP II.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ADDENDUM Page 1

2016-0111 180221 add 2 write up

ADDENDUM NO.: 2

PROJECT: GROSSE ILE TOWNSHIP SCHOOLS

BID PACK 2

MERIDIAN ELEMENTARY SITE IMPROPVEMENTS

GROSSE ILE HIGH SCHOOL SITE IMPROVEMENTS

GROSSE ILE HIGH SCHOOL SITE IMPROVEMENTS

Grosse Ile, Michigan

PROJECT NO: 2016-011.1 and 2016-013.1

OWNER: Grosse Ile Township Schools

DOCUMENTS ISSUED: January 15, 2018

ADDENDUM ISSUED: February 28, 2018

This Addendum is issued before the receiving of bids to clarify or to include certain revisions to the plans or specifications. All work required by this Addendum shall be in accordance with the original plans and apply to this project.

It is requested to include the work hereinafter described, in the proposal by the contractor for the complete work.

Clarifications:

1. A pre-bid meeting will be held at 3:00pm on Monday, March 5, 2018 at Grosse Ile High School 7800 Grays Drive, Grosse Ile, MI 48138. Please meet the main entrance lobby.

2. The bid due date has been extended to Monday, March 12, 2018 at 12:00pm. Please see the Instructions to bidders for specific requirements.

3. Regarding Grosse Ile High School- Cooling Tower

a. The new condenser water piping shall be insulated above and below the roof line.

4. Regarding Meridian Elementary:

a. PROPOSAL B: Site Concrete – Shall include the 9” Limestone Agg. Base, 21AA as shown in the Deep Strength Pavement Detail AP-D/C1.5A

Specification Changes:

1. Reference Section 32 2000 Earth Moving Clarification: This section is not applicable to the athletics scope of work

2. Reference Section 32 2001 Earthwork (refer to landscape Drawings) Clarification: This section is applicable to the athletics scope of work.

3. Reference Section 32 1817, Plant Mix Bituminous Asphalt Pavement - Track

Clarification: Related Sections reference Geotechnical Investigation Report and Section 32 1124 Aggregate Base Course.

Delete: “#1100T” from PART 1 – PRODUCTS, 2.1 Plant Mix, B. Wearing Course.

ADDENDUM NO. 2

Grosse Ile Township Schools Project No: 2016-011.1 Meridian Elementary and GIHS February 28, 2017 Page 2

2016-0111 180221 add 2 write up

Grosse Ile High School- Site Improvements Drawing Changes:

1. Refer to Sheet C1.3 (re-issued):

A. Correct the graphic scale to indicate the scale of the drawing as 1 inch = 30 feet.

2. Refer to new Sheet L1.00 (issued):

A. Add new sheet L1.00- Soil Erosion and Sedimentation Control Plan

3. Refer to new Sheet LD1.03 (issued):

A. Add new sheet LD1.03- Soil Erosion and Sedimentation Control Details

4. Refer to Proposal C: Fencing (issued):

A. Removed the base bid line

Grosse Ile High School- Cooling Tower Drawing Changes:

1. Refer to Sheet M7.0 – Piping Diagrams and Temperature Controls (issued):

A. Existing JCI Niagara system indicated in control sequence.