201076 Drawings.pdf

PDF 3 MB Posted

Attached to
Upgrade Exterior Doors & Security - Bray Hall
Solicitation number
2140285
Issued by
Onondaga County, New York

About this file

Summary of Project Drawings and Contract Opportunity

This is an architectural and engineering drawing package for the "Upgrade Exterior Doors & Security - Bray Hall" project at SUNY ESF Campus in Syracuse, New York. The project involves comprehensive security upgrades and entrance renovations at Bray Hall, including replacement of exterior and interior entrance storefront systems at the ground floor east entry; restoration of historic wood-framed, glazed entrance doors and transoms at the first floor west entry; and replacement of non-original aluminum-framed entrance systems at the north and south entries with wood-framed glazed systems matching the historic west entry. The scope encompasses abatement, demolition, concrete and exterior masonry restoration, architectural work, HVAC systems (including four electric radiator units for vestibule heating), electrical and fire alarm installations, and access control systems. The drawing set includes demolition plans, architectural floor plans and elevations, detailed door and hardware schedules, mechanical floor plans with radiator specifications, and electrical plans with access control door details. The project is designated as Project No. 201076 and was issued for permit as of October 26, 2026.

The contract opportunity includes minority/women business enterprise (MWBE) contracting goals of 15 percent for both minority-owned business enterprises (MBE) and women-owned business enterprises (WBE), and a 6 percent goal for service-disabled veteran-owned businesses (SDVOB). No identical or substantially similar procurement contracts have been awarded to businesses in the past five years. The project requires coordination among multiple design professionals including the architect (Holmes King Kallquist & Associates), mechanical and electrical engineers (FS Engineering, DPC), environmental engineers (Ravi Engineering & Land Surveying, P.C.), a door hardware consultant (Optimus Consulting), and a security/telecommunications consultant (Convergent Technologies Design Group, Inc.). The drawings indicate multiple work areas (East, West, North, and South) with specific requirements for temporary protection during demolition, coordination with existing building systems, and reinstallation of historic elements where applicable.

View the file

Other files

File Type Posted
201076 Project Manual.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

P h

) 4

F ax

) 4 w w w .h kk ar ch ite ct s.c om

H O

LM

ES

K

IN

G

A

LL

Q U

IS

T

As so cia tes , A rch ite cts , L

LP

ALL DRAWINGS AND SPECIFICATIONS ARE THE

PROPERTY OF THE ARCHITECT AND SHALL BE USED

ONLY ON THE JOB DESIGNATED. COPYRIGHT C

THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS

AT THE SITE AND PROMPTLY NOTIFY THE

ARCHITECT IN WRITING OF ANY DISCREPANCIES.

PA

RT

.5( b)

OF

TH

E

TIT

LE

V

III

ED

UC

AT

IO

N

LA

W O

F N

EW

Y

OR

K

PR

OH

IB

ITS

A

NY

A

ND

A

LL

A

LT

ER

AT

IO

NS

TO

TH

IS

D

RA

W

IN

G

OR

D

OC

UM

EN

T B Y

AN

Y

PE

RS

ON

, U

NL

ES

S

AC

TIN

G

UN

DE

R

TH

E

DI

RE

CT

IO

N

OF

A

LI

CE

NS

ED

A

RC

HI

TE

CT

. A

NY

S

UC

H

AL

TE

RA

TIO

NS

S

HA

LL

B E

NO

TE

D, S

EA

LE

D, A

ND

S

IG

NE

D

BY

TH

E

AL

TE

RI

NG

A

RC

HI

TE

CT

IN

A

CC

OR

DA

NC

E

W

ITH

TH

E

RE

QU

IR

EM

EN

TS

O F P

AR

T 6

9.5 b).

DATE:

JOB NO:

DRAWN BY:

SCALE:

N o rt h S al in a S tr ee t, S yr ac us e, N Y

PROJECT NORTH

I, THE UNDERSIGND ARCHITECT, CERTIFY

THAT TO THE BEST OF MY KNOWLEDGE,

INFORMATION, AND BELIEF, THE PLANS AND

SPECIFICATIONS ARE IN ACCORDANCE WITH

APPLICABLE REQUIREMENTS OF THE

AND THE

INTERNATIONAL BUILDING CODE

AS ADOPTED BY NEW YORK STATE

INTERNATIONAL ENERGY CONSERVATION CODE

AS ADOPTED BY NEW YORK STATE

ISSUE DATE

BID SET No.

HKK PROJECT No:

ABBREVIATIONS :

XX XX/XX/XX XX/XX/XX

DETAILDETAIL

LOCATIONLOCATION

SHEET #SHEET #

DETAIL KEYDETAIL KEY

SHEET #SHEET #

ELEVATIONELEVATION

LOCATIONLOCATION

SHEET #SHEET #

INTERIORINTERIOR

ELEVATIONELEVATION

KEYSKEYS

DETAILDETAIL

SECTIONSECTION

KEYKEY

SYMBOLS : LIST OF DRAWINGS :

DETAILDETAIL

LOCATIONLOCATION XX

AX.X

REVISIONS SYMBOLREVISIONS SYMBOL

X-X

AX.X

X-X

AX.X

DETAILDETAIL

LOCATIONLOCATION

SHEET #SHEET #

X-X

AX.X

EXTERIOREXTERIOR

ELEVATIONELEVATION

KEYSKEYS

XXX XXX

X

RELATES TORELATES TO

ROOM #ROOM #

WHERE MOREWHERE MORE

THAN ONE DOORTHAN ONE DOOR

ENTERS A ROOMENTERS A ROOM

APPLY A LETTERAPPLY A LETTER

ELEVATIONELEVATION

KEYKEY

WINDOW NUMBERWINDOW NUMBER

WALL TYPE KEYWALL TYPE KEY

FLOOR LEVEL

EL. X'-XX"

XXX

X

X-X

AX.X

DETAILDETAIL

LOCATIONLOCATION

SHEET #SHEET #

WALLWALL

SECTIONSECTION

KEYKEY

X-X

AX.X

SUNY ESF PROJECT No: 201076

/2

6/

0:

:2

AM

C

:\U se rs \lh un t\O ne D riv e

- H

KK

A ss oc ia te s Ar ch ite ct s\

D oc um en ts \R

_2

_S U

N Y

ES

F_

B ra y H al l_

C en tra l_ lh un t@ hk ka rc hi te ct s.

co m

.rv t

ISSUED FOR PERMIT

T1.1

TITLE SHEET &

DRAWING INDEX

(SYMBOLS &

ABBREVIATIONS)

25013

UP

GR

AD

E

EX

TE

RI

OR

D

OO

RS

S

EC

UR

IT

Y B

R A

Y H

A

LL

; S U

N Y

E

SF

10/26/26

LAH

SU

N

Y E

SF

C

A M

PU

S, S Y

R A

C U

SE

, N

EW

Y

O R

K

XX/XX/XX

BRAY HALL; SUNY ESF

SUNY ESF CAMPUS, SYRACUSE, NEW YORK

25013

UPGRADE EXTERIOR DOORS & SECURITY

ARCHITECT

HOLMES KING KALLQUIST

& ASSOCIATES, ARCHITECTS, LLP

575 NORTH SALINA STREET

SYRACUSE, NY 13208

PHONE: (315) 476-8371

WEBSITE: www.hkkarchitects.com

ACP/APC ACOUSTIC CEILING PANEL

ACT/ATC ACOUSTIC CEILING TILE

ADJ ADJACENT

AFF ABOVE FINISHED FLOOR

AIA AMERICAN INSTITUTE OF ARCHITECTS

ALLOW ALLOWANCE

ALT ALTERNATE

ALUM ALUMINUM

ANOD ANODIZED

APPROX APPROXIMATELY

ARCH ARCHITECT(URAL)

AVG AVERAGE

AWC ACOUSTICAL WALL COVERING

AWP ACOUSTIC CEILING PANELING

B/F BOTTOM OF FOOTING

BIT BITUMINOUS

BLDG BUILDING

BLKG BLOCKING

BM BEAM/BENCHMARK

B/O BOTTOM OF

BRD BOARD

BRK BRICK

BSMT BASEMENT

BTWN BETWEEN

BUR BUILT-UP ROOF

CABT CABINET

CEM CEMENT/CEMENTITIOUS

CF CUBIC FOOT/FEET

CJ CONTROL JOINT

CL CENTERLINE

CLG CEILING

CLO/CLS CLOSET

CLR CLEAR

CMU CONCRETE MASONRY UNIT

COL COLUMN/COLOR

COMP COMPOSITE

CONC CONCRETE

CONST CONSTRUCTION

CONT CONTINUOUS

CONTR CONTRACTOR

COORD COORDINATE

CORR CORRIDOR

CORRUG CORRUGATED

CPT CARPET

CPT.T. CARPET TILE

CRS COURSE(S)

CT CERAMIC TILE

CY CUBIC YARD

D DEPTH

DF DRINKING FOUNTAIN

DIA DIAMETER

DIAG DIAGONAL

DIM DIMENSION

DL DEAD LOAD

DN DOWN

DO DITTO

DR DOOR

DTL DETAIL

DWG DRAWING

EA EACH

EIFS EXTERIOR INSULATION FINISH SYSTEM

EJ EXPANSION JOINT

EL ELEVATION

ELEC ELECTRIC(AL)

ELEV ELEVATOR/ELEVATION

EM ENTRANCE MAT

ENTR ENTRANCE

EPS EXPANDED POLYSTYRENE

EQ EQUAL

EST ESTIMATE

EQUIP EQUIPMENT

EWC ELECTRIC WATER COOLER

EXH EXHAUST

EX OR

EXIST

EXISTING

EXT EXTERIOR

FD FLOOR DRAIN

FDN FOUNDTION

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

F/F FACE OF FINISH

FGL FIBERGLASS

FIN FINISH

FF OR FIN

FLR

FINISHED FLOOR

FIXT FIXTURE

FLR FLOOR

FM FACTORY MUTUAL

F/O FACE OF

FP FIRE PROOFING

FR FIRE RESISTIVE

FRMG FRAMING

FRP FIBERGLASS REINFORCED PLASTIC

FT FOOT/FEET OR FIRE TREATED

FTG FOOTING

FTRTD FIRE TREATED

FUR FURRING

FURN FURNITURE

GA GAUGE

GAL GALLON

GALV GALVANIZED

GC GENERAL CONTRACTOR

GEN GENERAL

GL GLASS/GLAZING

GNT GRANITE

GR GRADE

GRND GROUND

GT GLAZED TILE

GWB GYPSUM WALL BOARD

GYP GYPSUM

H HIGH

H/C HANDICAPPED ACCESSIBLE

HDWD HARDWOOD

HDWR HARDWARE

HGT HEIGHT

HM HOLLOW METAL

HORIZ HORIZONTAL

PART PARTITION

PBRD PARTICLE BOARD

PC COMPUTER

PED PEDIMAT

PERF PERFORATED

PL PLATE

PLAM PLASTIC LAMINATE

PLAS PLASTER

PLBG PLUMBING

PLYWD PLYWOOD

PNL PANEL

PNT PAINT

PREFAB PREFABRICATED

PREFIN PRE-FINISHED

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT PRESSURE TREATED

PTD PAINTED

PVC POLYVINYL CHLORIDE

PVMT PAVEMENT

QT QUARRY TILE

QTY QUANTITY

QTZ QUARTZ

R RISER OR RADIUS

RC RESILIENT CHANNEL

RD ROOF DRAIN

RECT RECTANGULAR

REF REFERENCE

REG REGULAR

REINF REINFORCE(D) (MENT)

REQD REQUIRED

RES RESILIENT FLOORING

REV REVISED/REVISION

RM ROOM

RO ROUGH OPENING

ROW RIGHT OF WAY

RUB RUBBER

SCHED SCHEDULE

SEC SECTION

SLNT SEALANT

SLR SEALER

SLT SLATE

SF SQUARE FOOT

SHT SHEET

SIM SIMILAR

SPEC SPECIFICATIONS

SPR SPRINKLER

SQ SQUARE

SS STAINLESS STEEL

SSM SOLID SURFACE MATERIAL

STC SOUND TRANSMISSION CLASS

STD STANDARD

STL STEEL

STN STAIN

STRUCT STRUCTURAL

SURF SURFACE

SUSP SUSPENDED

SY SQUARE YARD

HPC HIGH PRESSURE LAMINATE

HR HOUR

HVAC HEATING, VENTILATING & AIR

CONDITIONING

ID INSIDE DIAMETER

IN INCH

INCL INCLUDED/INCLUDING

INSUL INSULATION

INT INTERIOR

INV INVERT

JAN JANITOR

JT JOINT

L LENGTH

LAM LAMINATE(D)

LAV LAVATORY

LB POUND

LF LINEAR FEET

LG LIGHT GUAGE

LGMF LIGHT GUAGE METAL FRAMING

LIN MTL LINEAR METAL CEILING

LINO LINOLEUM

LL LIVE LOAD

LLH LONG LEG HORIZONTAL

LLV LONG LEG VERTICAL

LOC LOCATION

LTG LIGHTING

LTL LINTEL

LVL LAMINATED VENEER LUMBER

LVP LUXERY VINYL PLANK

LVR LOUVER

LVT LUXERY VINYL TILE

MAR MARBLE

MAS MASONRY

MAT MATERIAL

MAX MAXIMUM

MDF MEDIUM DENSITY FIBERBOARD

MDO MEDIUM DENSITY OVERLAY

MECH MECHANICAL

MEZZ MEZZANINCE

MFR MANUFACTURER

MIN MINIMUM

MISC MISCELLANEOUS

MO MASONRY OPENING

MTL METAL

NA NOT APPLICABLE

NIC NOT IN CONTRACT

NO OR # NUMBER

NOM NOMINAL

NTS NOT TO SCALE

OA OVERALL

OC ON CENTER

OD OUTSIDE DIAMETER

OH OVERHEAD

OPNG OPENING

OPP OPPOSITE

OPPH OPPOSITE HAND

OSB ORIENTED STRAND BOARD

OZ OUNCE

SYM SYMMETRICAL

T TREAD

TEL TELEPHONE

TEMP TEMPORARY

TERR TERRAZZO

THK THICK

THRESH THRESHOLD

T&G TONGUE & GROOVE

T/O TOP OF

TLT TOILET

T/S TOP OF STEEL

TTL TOTAL

TV TELEVISION

TYP TYPICAL

UL UNDERWRITER'S LABORATORY

UNO UNLESS NOTED OTHERWISE

UR URINAL

VAR VARIES/VARIABLE

VARN VARNISH

VB VAPOR BARRIER

VCT VINYL COMPOSITION TILE

VERT VERTICAL

VEST VESTIBULE

VET VINYL ENHANCED TILE

VIF VERIFY IN FIELD

VNR VENEER

VTR VENT THROUGH ROOF

VWC VINYL WALL COVERING

W WIDE

W/ WITH

WC WATER CLOSET OR WALL COVERING

WD WOOD

WD PNL WOOD PANELING

WF WIDE FLANGE

WIN WINDOW

W/O WITHOUT

WR WATER RESISTANT

WT WEIGHT

WWF WELDED WIRE FABRIC

Sheet Number Sheet Name

GENERAL

T1.1 TITLE SHEET & DRAWING INDEX (SYMBOLS & ABBREVIATIONS)

ARCHITECTURAL

D1.1 GROUND & FIRST FLOOR DEMOLITION PLANS & ELEVATIONS

A1.1 FLOOR PLANS AND ELEVATIONS

A4.1 ENLARGED PLAN, INTERIOR ELEVATIONS

A5.1 DETAILS

A5.2 DETAILS

A5.3 DETAILS

A7.1 DOOR SCHEDULE

MECHANICAL

M001 DRAWING INDEX, SYMBOLS & ABBREVS.

M101 FLOOR PLAN, SCHEDULE AND SEQUENCES

ELECTRICAL

E001 DRAWING INDEX, SYMBOLS & ABBREVS.

E100 GROUND FLOOR PLANS

E101 FIRST FLOOR PLANS

SECURITY / TELECOMMUNICATIONS

TY0.01 LOW VOLTAGE SYSTEM TITLE SHEET

TY1.01 BRAY HALL SECURITY SYSTEMS - GROUND FLOOR PLAN

TY1.02 BRAY HALL SECURITY SYSTEMS - FIRST FLOOR PLAN

TY5.01 ACCESS CONTROL DOOR DETAILS

MEP/FP ENGINEER

FS ENGINEERING, DPC

721 EAST GENESEE STREET, LOWER LEVEL

SYRACUSE , NY 13210

PHONE: (315) 471-4013

WEBSITE: www.fsengineering.pro

ENVIRONMENTAL ENGINEERS

RAVI ENGINEERING & LAND

SURVEYING, P.C.

2110 SOUTH CLINTON AVE, SUITE 1

ROCHESTER , NY 14618

PHONE: (585) 223-3660

WEBSITE: www.ravieng.com

DOOR HARDWARE CONSULTANT

OPTIMUS CONSULTING

34 JACKIM ROAD

OSWEGO, NY 131262

PHONE: (315) 216-6826

WEBSITE: www.optimussalesllc.com

SECURITY /

TELECOMMUNICATIONS

CONSULTANT

CONVERGENT TECHNOLOGIES

DESIGN GROUP, INC.

4849 MIDDLETOWN DRIVE

LOCKPORT, NY 14094

PHONE: 716-898-8135

WEBSITE: www.ctdginc.com

COST ESTIMATING CONSULTANT

TROPHY POINT, LLC

4588 SOUTH PARK AVENUE

BLASDELL, NY 14219

PHONE: (716) 823-0006

WEBSITE: www.trophypoint.com

REV.

NO.: DATE: DRAWN

BY: DESCRIPTION:

D-1 A1.1

EXISTING HOLLOW METAL DOORS,

FRAMES & ASSOC. HARDWARE TO

TO BE REMOVED IN THEIR ENTIRETY.

PROVIDE TEMPORARY PROTECTION.

EXISTING HOLLOW

METAL DOORS,

FRAMES & ASSOC.

HARDWARE TO

TO BE REMOVED IN

THEIR ENTIRETY

EXISTING EXTERIOR DOORS, FRAMES, TRANSOMS

AND ASSOCIATED HARDWARE TO BE REMOVED

IN THEIR ENTIRETY.

REMOVE PANIC BARS, TOP & BOTTOM

BOLTS, CLOSERS, HOLD OPENS, PULLS,

LOCKSETS, & TRANSOM HARDWARE - TURN

OVER TO CAMPUS.REMOVE GLAZING STOPS

AND GLAZING AT DOORS ONLY. PROVIDE

TEMPORARY PROTECTION.

D1.1

D-3

C-3 D1.1

EXISTING EXTERIOR DOORS, FRAMES, TRANSOMS

AND ASSOCIATED HARDWARE TO BE REMOVED

IN THEIR ENTIRETY. PROVIDE TEMPORARY

PROTECTION.

D-2 D1.1

EXISTING EXTERIOR DOORS, FRAMES, TRANSOMS

AND ASSOCIATED HARDWARE TO BE REMOVED

IN THEIR ENTIRETY. PROVIDE TEMPORARY

PROTECTION.

D-2 D1.1

FLOOR 1

7' - 0"

FLOOR 2

21' - 0"

EXISTING OUTER EXTERIOR DOORS, FRAMES, TRANSOMS

AND ASSOCIATED HARDWARE TO BE REMOVED

IN THEIR ENTIRETY.

EXISTING HOLLOW METAL DOORS, FRAME

& ASSOC. HARDWARE TO BE REMOVED IN

THEIR ENTIRETY. PROVIDE TEMPORARY

PROTECTION.

EXISTING EXTERIOR DOORS, FRAMES, TRANSOMS

AND ASSOCIATED HARDWARE TO BE REMOVED

IN THEIR ENTIRETY. PROVIDE TEMPORARY PROTECTION.

WORK AREA -

EAST

WORK AREA - WEST

WORK AREA -

NORTH

WORK AREA -

SOUTH

FLOOR 1

7' - 0"

REMOVE PANIC BARS, TOP & BOTTOM BOLTS, CLOSERS, HOLD OPENS, PULLS, AND

LOCKSETS AND TURN OVER TO CAMPUS. REMOVE GLAZING STOPS AND GLAZING AT

DOORS ONLY. PROVIDE TEMPORARY PROTECTION.

REMOVE TRANSOM HARDWARE

WITH EXCEPTION OF PIVOT HINGE

AND CLASP. REMOVE STOP AT

TOP OF TRANSOM AND FASTEN IN

PLACE.

SAW CUT BOTTOM OF OPERABLE DOORS TO

ACCOMODATE NEW THRESHOLD. COORD.

W/ SPEC SECTION 087100.

P h

) 4

) 4 w w w .h kk ar ch ite ct s.c om

H O

LL

Q U

IS

T

As so cia tes , A rch ite cts , L

LP

ALL DRAWINGS AND SPECIFICATIONS ARE THE

PROPERTY OF THE ARCHITECT AND SHALL BE USED

ONLY ON THE JOB DESIGNATED. COPYRIGHT C

THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS

AT THE SITE AND PROMPTLY NOTIFY THE

ARCHITECT IN WRITING OF ANY DISCREPANCIES.

PA

RT

.5( b)

OF

TH

E

TIT

LE

V

III

ED

UC

AT

IO

N

LA

W O

F N

EW

Y

OR

K

PR

OH

IB

ITS

A

NY

A

ND

A

LL

A

LT

ER

AT

IO

NS

TO

TH

IS

D

RA

W

IN

G

OR

D

OC

UM

EN

T B Y

AN

Y

PE

RS

ON

, U

NL

ES

S

AC

TIN

G

UN

DE

R

TH

E

DI

RE

CT

IO

N

OF

A

LI

CE

NS

ED

A

RC

HI

TE

CT

. A

NY

S

UC

H

AL

TE

RA

TIO

NS

S

HA

LL

B E

NO

TE

D, S

EA

LE

D, A

ND

S

IG

NE

D

BY

TH

E

AL

TE

RI

NG

A

RC

HI

TE

CT

IN

A

CC

OR

DA

NC

E

W

ITH

TH

E

RE

QU

IR

EM

EN

TS

O F P

AR

T 6

9.5 b).

DATE:

JOB NO:

DRAWN BY:

SCALE:

N o rt h S al in a S tr ee t, S yr ac us e, N Y

PROJECT NORTH

/2

6/

0:

:2

AM

C

:\U se rs \lh un t\O ne D riv e

- H

KK

A ss oc ia te s Ar ch ite ct s\

D oc um en ts \R

_2

_S U

N Y

ES

F_

B ra y H al l_

C en tra l_ lh un t@ hk ka rc hi te ct s.

co m

.rv t

As indicated

ISSUED FOR PERMIT

D1.1

GROUND & FIRST

FLOOR DEMOLITION

PLANS &

ELEVATIONS

25013

UP

GR

AD

E

EX

TE

RI

OR

D

OO

RS

S

EC

UR

IT

Y B

R A

Y H

A

LL

; S U

N Y

E

SF

10/26/26

LAH

SU

N

Y E

SF

C

A M

PU

S, S Y

R A

C U

SE

, N

EW

Y

O R

K

SCALE: 1/4" = 1'-0"SCALE: 1/4" = 1'-0" D1.1D1.1

A-2A-2PARTIAL GROUND FLOOR DEMOLITION PLANPARTIAL GROUND FLOOR DEMOLITION PLAN

SCALE: 1/4" = 1'-0"SCALE: 1/4" = 1'-0" D1.1D1.1

A-3A-3PARTIAL FIRST FLOOR DEMOLITION PLAN - WESTPARTIAL FIRST FLOOR DEMOLITION PLAN - WEST

SCALE: 1/4" = 1'-0"SCALE: 1/4" = 1'-0" D1.1D1.1

C-1C-1PARTIAL FIRST FLOOR DEMOLITION PLAN - NORTHPARTIAL FIRST FLOOR DEMOLITION PLAN - NORTH

SCALE: 1/4" = 1'-0"SCALE: 1/4" = 1'-0" D1.1D1.1

C-2C-2PARTIAL FIRST FLOOR DEMOLITION PLAN - SOUTHPARTIAL FIRST FLOOR DEMOLITION PLAN - SOUTH

SCALE: 1/4" = 1'-0"SCALE: 1/4" = 1'-0" D1.1D1.1

C-3C-3DEMOLITION - WEST ELEVATIONDEMOLITION - WEST ELEVATION

SCALE: 1/4" = 1'-0"SCALE: 1/4" = 1'-0" D1.1D1.1

D-1D-1DEMOLITION - EAST ELEVATIONDEMOLITION - EAST ELEVATION

SCALE: 1/4" = 1'-0"SCALE: 1/4" = 1'-0" D1.1D1.1

D-2D-2DEMOLITION - NORTH & SOUTH ELEVATIONDEMOLITION - NORTH & SOUTH ELEVATION

SCALE: 1" = 40'-0"SCALE: 1" = 40'-0" D1.1D1.1

A-1A-1GROUND FLOOR KEY PLAN - DEMOLITIONGROUND FLOOR KEY PLAN - DEMOLITION

SCALE: 1" = 40'-0"SCALE: 1" = 40'-0" D1.1D1.1

B-1B-1FIRST FLOOR KEY PLAN - DEMOLITIONFIRST FLOOR KEY PLAN - DEMOLITION

SCALE: 1/4" = 1'-0"SCALE: 1/4" = 1'-0" D1.1D1.1

D-3D-3DEMOLITION INTERIOR ELEVATION - WEST ENTRYDEMOLITION INTERIOR ELEVATION - WEST ENTRY

REV.

A4.1 A-1

RESTORE GRANITE FLOOR & TERRA

COTTA WALLS AS REQ'D AT AREAS

OF STOREFRONT REMOVAL

101101

VESTIBULEVESTIBULE

PROVIDE NEW WOOD-FRAMED

GLAZED STORM SASH AT FLANKING

TRANSOMS

101C

101A 101D

101B

C-3 A1.1

D-2 A1.1

A-2 A5.1

Sim 103103

STAIR -STAIR -

SOUTHSOUTH 103

A5.1 A-1

CARD

READER

D-2 A1.1 A-2

A5.1 104104

STAIR -STAIR -

NORTHNORTH A5.2A-1

A5.1 A-1

CARD

READER

D-1 A1.1

A5.2

B-1

G01G01

VESTIBULEVESTIBULE

CARD

READER

PUSH

PAD (PP)

PP

PROVIDE NEW GLAZED

ALUMINUM PANEL DOOR,

INSULATED PANEL,

FRAME AND HARDWARE

G01

G02

A7.1 A-3

A7.1 A-2

ALUMINUM STOREFRONT

ENTRY AND SIDELIGHTS

INSULATED METAL

PANELS

B-3

A7.1

A-3

A7.1

FLOOR 1

7' - 0"

FLOOR 2

21' - 0"

EXISTING WOOD DOORS, TRANSOM AND

FRAMING TO REMAIN. FIX & WEATHERSTRIP

DOORS IN PLACE. REPAIR WOODWORK AT

AREAS OF HARDWARE REMOVAL. PROVIDE

NEW INSULATED GLAZING AND WOOD GLAZING

STOPS, BOTH SIDES.

[FIXED] [OPERABLE] [FIXED]

NOTE:

PATCH ANY HOLES AND FASTENER

LOCATIONS IN DOORS AND FRAME

WHERE HARDWARE IS SCHEDULED TO

BE REMOVED OR REPLACED, INCLUDING

DOOR EDGES.

A-2 A5.1

A5.1 A-3

WORK AREA -

EAST

WORK AREA - WEST

WORK AREA -

NORTH

WORK AREA -

SOUTH

P h

) 4

) 4 w w w .h kk ar ch ite ct s.c om

H O

LL

Q U

IS

T

As so cia tes , A rch ite cts , L

LP

ALL DRAWINGS AND SPECIFICATIONS ARE THE

PROPERTY OF THE ARCHITECT AND SHALL BE USED

ONLY ON THE JOB DESIGNATED. COPYRIGHT C

THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS

AT THE SITE AND PROMPTLY NOTIFY THE

ARCHITECT IN WRITING OF ANY DISCREPANCIES.

PA

RT

.5( b)

OF

TH

E

TIT

LE

V

III

ED

UC

AT

IO

N

LA

W O

F N

EW

Y

OR

K

PR

OH

IB

ITS

A

NY

A

ND

A

LL

A

LT

ER

AT

IO

NS

TO

TH

IS

D

RA

W

IN

G

OR

D

OC

UM

EN

T B Y

AN

Y

PE

RS

ON

, U

NL

ES

S

AC

TIN

G

UN

DE

R

TH

E

DI

RE

CT

IO

N

OF

A

LI

CE

NS

ED

A

RC

HI

TE

CT

. A

NY

S

UC

H

AL

TE

RA

TIO

NS

S

HA

LL

B E

NO

TE

D, S

EA

LE

D, A

ND

S

IG

NE

D

BY

TH

E

AL

TE

RI

NG

A

RC

HI

TE

CT

IN

A

CC

OR

DA

NC

E

W

ITH

TH

E

RE

QU

IR

EM

EN

TS

O F P

AR

T 6

9.5 b).

DATE:

JOB NO:

DRAWN BY:

SCALE:

N o rt h S al in a S tr ee t, S yr ac us e, N Y

PROJECT NORTH

/2

6/

0:

:3

AM

C

:\U se rs \lh un t\O ne D riv e

- H

KK

A ss oc ia te s Ar ch ite ct s\

D oc um en ts \R

_2

_S U

N Y

ES

F_

B ra y H al l_

C en tra l_ lh un t@ hk ka rc hi te ct s.

co m

.rv t

As indicated

ISSUED FOR PERMIT

A1.1

FLOOR PLANS AND

ELEVATIONS

25013

UP

GR

AD

E

EX

TE

RI

OR

D

OO

RS

S

EC

UR

IT

Y B

R A

Y H

A

LL

; S U

N Y

E

SF

10/26/26

LAH

SU

N

Y E

SF

C

A M

PU

S, S Y

R A

C U

SE

, N

EW

Y

O R

K

SCALE: 1/4" = 1'-0"SCALE: 1/4" = 1'-0" A1.1A1.1

A-3A-3PARTIAL FIRST FLOOR PLAN - WESTPARTIAL FIRST FLOOR PLAN - WEST

SCALE: 1/4" = 1'-0"SCALE: 1/4" = 1'-0" A1.1A1.1

C-1C-1PARTIAL FIRST FLOOR PLAN - SOUTHPARTIAL FIRST FLOOR PLAN - SOUTH

SCALE: 1/4" = 1'-0"SCALE: 1/4" = 1'-0" A1.1A1.1

C-2C-2PARTIAL FIRST FLOOR PLAN - NORTHPARTIAL FIRST FLOOR PLAN - NORTH

SCALE: 1/4" = 1'-0"SCALE: 1/4" = 1'-0" A1.1A1.1

A-2A-2PARTIAL GROUND FLOOR PLANPARTIAL GROUND FLOOR PLAN

SCALE: 1/4" = 1'-0"SCALE: 1/4" = 1'-0" A1.1A1.1

D-1D-1EAST ELEVATIONEAST ELEVATION

SCALE: 1/4" = 1'-0"SCALE: 1/4" = 1'-0" A1.1A1.1

C-3C-3WEST ELEVATIONWEST ELEVATION

SCALE: 1/4" = 1'-0"SCALE: 1/4" = 1'-0" A1.1A1.1

D-2D-2NORTH AND SOUTH ELEVATIONNORTH AND SOUTH ELEVATION

SCALE: 1" = 40'-0"SCALE: 1" = 40'-0" A1.1A1.1

A-1A-1GROUND FLOOR KEY PLAN - NEW WORKGROUND FLOOR KEY PLAN - NEW WORK

SCALE: 1" = 40'-0"SCALE: 1" = 40'-0" A1.1A1.1

B-1B-1FIRST FLOOR KEY PLAN - NEW WORKFIRST FLOOR KEY PLAN - NEW WORK

REV.

B-1 A4.1

A4.1A-3

B-2

A-2

PP OUT

PP INCR

PP OUT

PP IN

PP = PUSH PAD

CR = CARD READER

A5.1 C-3

101A

101B

PROVIDE NEW BUTT-GLAZED

STOREFRONT SYSTEM, BOTH

SIDES

PROVIDE NEW BUTT-GLAZED

ENTRANCE STOREFRONT SYSTEM

A5.1 C-4

[FIXED] [OPERABLE] [FIXED]

PROVIDE NEW WOOD FRAMED GLAZED

STORM SASH AT TRANSOMS.

PROVIDE NEW INSULATED

GLAZING AND GLAZING STOPS

AT FLANKING DOORS.

NOTE:

PATCH ANY HOLES AND FASTENER

LOCATIONS IN DOORS AND FRAMES

WHERE HARDWARE IS SCHEDULED TO

BE REMOVED OR REPLACED, INCLUDING

DOOR EDGES.

ELECTRIC

RADIATOR,

TYP.

A5.1 C-2

D-2

A5.2

C-4

A5.1

C-3

A5.1

PROVIDE NEW BUTT-GLAZED

ENTRANCE STOREFRONT SYSTEM

C-5

A5.1

C-2

A5.1

B-1 A4.1

C-3

A5.1

C-4

A5.1

/8

PROVIDE NEW BUTT-GLAZED

STOREFRONT SYSTEM

ELECTRIC

RADIATOR

SEE MECH DWGS

C-2

A5.1

B-1 A4.1

C-4

A5.1

C-3

A5.1

A5.1 C-4

PROVIDE NEW BUTT-GLAZED

STOREFRONT SYSTEM

ELECTRIC

RADIATOR.

SEE MECH

DWGS

C-2

A5.1

P h

) 4

) 4 w w w .h kk ar ch ite ct s.c om

H O

LL

Q U

IS

T

As so cia tes , A rch ite cts , L

LP

ALL DRAWINGS AND SPECIFICATIONS ARE THE

PROPERTY OF THE ARCHITECT AND SHALL BE USED

ONLY ON THE JOB DESIGNATED. COPYRIGHT C

THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS

AT THE SITE AND PROMPTLY NOTIFY THE

ARCHITECT IN WRITING OF ANY DISCREPANCIES.

PA

RT

.5( b)

OF

TH

E

TIT

LE

V

III

ED

UC

AT

IO

N

LA

W O

F N

EW

Y

OR

K

PR

OH

IB

ITS

A

NY

A

ND

A

LL

A

LT

ER

AT

IO

NS

TO

TH

IS

D

RA

W

IN

G

OR

D

OC

UM

EN

T B Y

AN

Y

PE

RS

ON

, U

NL

ES

S

AC

TIN

G

UN

DE

R

TH

E

DI

RE

CT

IO

N

OF

A

LI

CE

NS

ED

A

RC

HI

TE

CT

. A

NY

S

UC

H

AL

TE

RA

TIO

NS

S

HA

LL

B E

NO

TE

D, S

EA

LE

D, A

ND

S

IG

NE

D

BY

TH

E

AL

TE

RI

NG

A

RC

HI

TE

CT

IN

A

CC

OR

DA

NC

E

W

ITH

TH

E

RE

QU

IR

EM

EN

TS

O F P

AR

T 6

9.5 b).

DATE:

JOB NO:

DRAWN BY:

SCALE:

N o rt h S al in a S tr ee t, S yr ac us e, N Y

PROJECT NORTH

/2

6/

0:

:3

AM

C

:\U se rs \lh un t\O ne D riv e

- H

KK

A ss oc ia te s Ar ch ite ct s\

D oc um en ts \R

_2

_S U

N Y

ES

F_

B ra y H al l_

C en tra l_ lh un t@ hk ka rc hi te ct s.

co m

.rv t

3/8" = 1'-0"

ISSUED FOR PERMIT

A4.1

ENLARGED PLAN,

INTERIOR

ELEVATIONS

25013

UP

GR

AD

E

EX

TE

RI

OR

D

OO

RS

S

EC

UR

IT

Y B

R A

Y H

A

LL

; S U

N Y

E

SF

10/26/26

LAH

SU

N

Y E

SF

C

A M

PU

S, S Y

R A

C U

SE

, N

EW

Y

O R

K

SCALE: 3/8" = 1'-0"SCALE: 3/8" = 1'-0" A4.1A4.1

A-1A-1ENLARGED PARTIAL FIRST FLOOR PLAN - WESTENLARGED PARTIAL FIRST FLOOR PLAN - WEST

SCALE: 3/8" = 1'-0"SCALE: 3/8" = 1'-0" A4.1A4.1

B-1B-1INTERIOR ELEVATION - WESTINTERIOR ELEVATION - WEST

SCALE: 3/8" = 1'-0"SCALE: 3/8" = 1'-0" A4.1A4.1

B-2B-2INTERIOR ELEVATION - EASTINTERIOR ELEVATION - EAST

SCALE: 3/8" = 1'-0"SCALE: 3/8" = 1'-0" A4.1A4.1

A-2A-2INTERIOR ELEVATION - SOUTHINTERIOR ELEVATION - SOUTH

SCALE: 3/8" = 1'-0"SCALE: 3/8" = 1'-0" A4.1A4.1

A-3A-3INTERIOR ELEVATION - NORTHINTERIOR ELEVATION - NORTH

REV.

9 1/2"

A5.3 B-2

A5.2 A-3

A5.3 A-4

EXISTING RAILING TO BE

REINSTALLED, PNT'D

FLOOR 1

7' - 0"

A-2 A5.1

A-2

A5.2

B-2

A5.2

C-2

A5.2

7' - 0"

8'

0" 2'

1/ 4"

3'

3/

4"

2"

1/

2"

3'

3"

1/ 4"

7/

8"

1/

2"

1'

1/

8"

1/

2"

1/

2"

7/ 8"

4'

4"

7/ 8"

1'

4" 1'

1"

1 3/8" 1' - 4 7/8" 3 3/4" 3 '- 4". 3 3/4" 1'-4 7/8". 1 3/8"

A-1

A5.3

GLASS WALL OFFICE SYSTEM

EXISTING SOFFIT

EQ EQ

GLASS WALL OFFICE SYSTEM

3/4" WOOD TRIM, PNT.

2X WD BLOCKING

LINE OF PILASTER

EXISTING BASE BELOW

GLASS WALL OFFICE SYSTEM

5 1/4"

5/8"

1/8"

7/8"

1/8"

2 1/4"

1/4"

1 1/8"

7/

8"

1/ 8"

1/ 8"

1/ 8"

1/ 8"

5/ 8"

1/ 8"

NOTE:

ALL EXPOSED WOODWORK TO BE

QUARTER SAWN WHITE OAK - MATCH

FINISH OF WEST ENTRY

1/ 4"

1"

1/ 4"

3/

8"

3/ 4"

3/ 4"

1/

4"

1/4" 1 1/8" 1/2" 5/8"

1/4"

FACE OF EXISTING MASONRY

7/8" 1"

3/8"

3/8"

1/2"

CASING - SEE B-1/A5.1

INTERIOR FINISH

PLYWD FURRING

WOOD BLOCKING

INTERIORINTERIOR

EXTERIOREXTERIOR

1/ 4"

2" 3/

4"

3/ 4"

3/

8"

1/ 2"

1/ 2"

1/ 4"

3/8"

3/8"

1/4"

3 1/4"

1/4"

3/8" 3/8"

3/8" 1/2" 3/4" 1/2" 3/4" 1/2" 3/8"

WOOD-FRAMED BOX

BEAM (2 3/4" X 7 13/16"

NOTE:

ALL EXPOSED WOODWORK

TO BE QUARTER SAWN WHITE

OAK. MATCH FINISH OF WEST

ENTRY.

HEADER

4" DOOR RAIL

3/8" TEMPERED

GLASS

EXISTING HEADER

P h

) 4

) 4 w w w .h kk ar ch ite ct s.c om

H O

LL

Q U

IS

T

As so cia tes , A rch ite cts , L

LP

ALL DRAWINGS AND SPECIFICATIONS ARE THE

PROPERTY OF THE ARCHITECT AND SHALL BE USED

ONLY ON THE JOB DESIGNATED. COPYRIGHT C

THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS

AT THE SITE AND PROMPTLY NOTIFY THE

ARCHITECT IN WRITING OF ANY DISCREPANCIES.

PA

RT

.5( b)

OF

TH

E

TIT

LE

V

III

ED

UC

AT

IO

N

LA

W O

F N

EW

Y

OR

K

PR

OH

IB

ITS

A

NY

A

ND

A

LL

A

LT

ER

AT

IO

NS

TO

TH

IS

D

RA

W

IN

G

OR

D

OC

UM

EN

T B Y

AN

Y

PE

RS

ON

, U

NL

ES

S

AC

TIN

G

UN

DE

R

TH

E

DI

RE

CT

IO

N

OF

A

LI

CE

NS

ED

A

RC

HI

TE

CT

. A

NY

S

UC

H

AL

TE

RA

TIO

NS

S

HA

LL

B E

NO

TE

D, S

EA

LE

D, A

ND

S

IG

NE

D

BY

TH

E

AL

TE

RI

NG

A

RC

HI

TE

CT

IN

A

CC

OR

DA

NC

E

W

ITH

TH

E

RE

QU

IR

EM

EN

TS

O F P

AR

T 6

9.5 b).

DATE:

JOB NO:

DRAWN BY:

SCALE:

N o rt h S al in a S tr ee t, S yr ac us e, N Y

PROJECT NORTH

/2

6/

0:

:3

AM

C

:\U se rs \lh un t\O ne D riv e

- H

KK

A ss oc ia te s Ar ch ite ct s\

D oc um en ts \R

_2

_S U

N Y

ES

F_

B ra y H al l_

C en tra l_ lh un t@ hk ka rc hi te ct s.

co m

.rv t

As indicated

ISSUED FOR PERMIT

A5.1

DETAILS

25013

UP

GR

AD

E

EX

TE

RI

OR

D

OO

RS

S

EC

UR

IT

Y B

R A

Y H

A

LL

; S U

N Y

E

SF

10/26/26

Author

SU

N

Y E

SF

C

A M

PU

S, S Y

R A

C U

SE

, N

EW

Y

O R

K

SCALE: 3/4" = 1'-0"SCALE: 3/4" = 1'-0" A5.1A5.1

A-2A-2SECTION THRU NORTH STAIR DOORSECTION THRU NORTH STAIR DOOR

SCALE: 3/4" = 1'-0"SCALE: 3/4" = 1'-0" A5.1A5.1

A-3A-3NORTH AND SOUTH STAIR ENTRYNORTH AND SOUTH STAIR ENTRY

SCALE: 3" = 1'-0"SCALE: 3" = 1'-0" A5.1A5.1

C-4C-4HEAD DETAIL AT GLASS WALL SYSTEMHEAD DETAIL AT GLASS WALL SYSTEM

SCALE: 3" = 1'-0"SCALE: 3" = 1'-0" A5.1A5.1

C-3C-3JAMB DETAIL AT GLASS WALL SYSTEMJAMB DETAIL AT GLASS WALL SYSTEM

SCALE: 3" = 1'-0"SCALE: 3" = 1'-0" A5.1A5.1

C-2C-2SILL DETAIL AT GLASS WALL SYSTEMSILL DETAIL AT GLASS WALL SYSTEM

SCALE: 6" = 1'-0"SCALE: 6" = 1'-0" A5.1A5.1

A-1A-1DOOR JAMB DETAILDOOR JAMB DETAIL

SCALE: 6" = 1'-0"SCALE: 6" = 1'-0" A5.1A5.1

B-1B-1DOOR CASING TRIMDOOR CASING TRIM

SCALE: 6" = 1'-0"SCALE: 6" = 1'-0" A5.1A5.1

C-1C-1DOOR MULLION DETAILDOOR MULLION DETAIL

SCALE: 3" = 1'-0"SCALE: 3" = 1'-0" A5.1A5.1

C-5C-5DETAIL AT DOOR HEADDETAIL AT DOOR HEAD

REV.

A-2 A5.1

DOOR CASING

TRIM - SEE DETAIL

B-1/A5.1

EXISTING CONCRETE

LANDING

A-1

A5.3

EXISTING RAILING

TO BE REINSTALLED,

PNTD

7'

5"

6' - 8"

INSULATED METAL

PANEL

TEMPERED INSULATED

GLASS

4" RUBBER BASE

2" 1' - 4" 2" 3' - 4" 2" 1' - 4" 2"

2" 3'

2"

2'

3" 1'

0"

A-3

A7.1

B-3

A7.1

DRYWALL 'F' REVEAL

A5.1 A-1

A5.1 C-1

A5.1 B-1

7' - 0"

1 3/8" 1' - 4 7/8" 3 3/4" 3' - 4" 3 3/4" 1' - 4 7/8" 1 3/8"

A5.1 B-1

7' - 0"3 1/8"

6" 1' - 10 3/8" 1' - 9" 1' - 10 3/8" 6"

3 1/8"

A5.3 B-3

7' - 0"

1' - 6 3/4" 2 3/4" 3' - 5" 2 3/4" 1' - 6 3/4"

5/8" PLYWOOD

2X6 WD STUDS

@ 16" O.C.

3/4" PLYWOOD

5 1/2" BATT

INSULATION

1 1/2"1 1/2"

1' - 1 7/8" 1 1/2" 3' - 2"

1 1/2"

1' - 1 7/8"

1 1/2"

5/8" 1 3/8" 3/4"

3/

8" 1/

2"

1/2" 1/2" 3/

4"

EXISTING CASING

EXISTING TRANSOM - FIXED IN

PLACE. MAKE SURE TRANSOM IS

CLOSED TIGHTLY IN A VERTICAL

POSITION.

STORM WINDOW -

QUARTER SAWN WHITE

OAK. MATCH FINISH OF

ADJACENT TRIM.

ALIGN

FACE OF EXISTING MASONRY

5/ 8"

3/

8" 3/

4"

1 3/8" 1/2"

1/ 2"

1/ 2"

3/4"

EXISTING TRANSOM - FIXED

IN PLACE. MAKE SURE TRANSOM

IS CLOSED TIGHTLY IN A VERTICAL

POSITION

STORM WINDOW - QUARTER

SAWN WHITE OAK. MATCH

FINISH OF ADJACENT TRIM

EXISTING CASING

EXISTING JAMB TRIM

EXISTING CONCRETE

LANDING

5/8" GWB

5/8" PLYWOOD

2X6 @ 16" O.C.

2'

1/

4"

1/

4" 1"

1/ 4"

1/2" 5/8" 5 1/2"

5/8"

5/8"

1/

4" 3/

8" 3/

4"

3/ 4"

1'

1/

4" 3/

4"

3/ 4"

1/

2"

3/ 8"

5/ 8"

1/4"

3/4"

1/2" 3"

3 1/4"

3/8" 1/4"

3"

7/ 8"

3" 5/

8"

3/ 8"

3/ 4"

2 1/4"

3/8"

1" 1/8"

2 1/4" 2 3/8"

3/4"

2 7/8"

CASING TRIM

SEE B-1/A5.1

3/ 4"

3/

8" 7"

ALIGN

5/8"

3/4"

7/8"

NOTE: ALL EXPOSED WOOD

TO BE QUARTER SAWN

WHITE OAK - MATCH FINISH

OF WEST ENTRY.

7 3/4" STONE SILL AND BASE

TO MATCH EXISTING

EXISTING RAILING TO BE REINSTALLED

A5.3 B-4

P h

) 4

) 4 w w w .h kk ar ch ite ct s.c om

H O

LL

Q U

IS

T

As so cia tes , A rch ite cts , L

LP

ALL DRAWINGS AND SPECIFICATIONS ARE THE

PROPERTY OF THE ARCHITECT AND SHALL BE USED

ONLY ON THE JOB DESIGNATED. COPYRIGHT C

THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS

AT THE SITE AND PROMPTLY NOTIFY THE

ARCHITECT IN WRITING OF ANY DISCREPANCIES.

PA

RT

.5( b)

OF

TH

E

TIT

LE

V

III

ED

UC

AT

IO

N

LA

W O

F N

EW

Y

OR

K

PR

OH

IB

ITS

A

NY

A

ND

A

LL

A

LT

ER

AT

IO

NS

TO

TH

IS

D

RA

W

IN

G

OR

D

OC

UM

EN

T B Y

AN

Y

PE

RS

ON

, U

NL

ES

S

AC

TIN

G

UN

DE

R

TH

E

DI

RE

CT

IO

N

OF

A

LI

CE

NS

ED

A

RC

HI

TE

CT

. A

NY

S

UC

H

AL

TE

RA

TIO

NS

S

HA

LL

B E

NO

TE

D, S

EA

LE

D, A

ND

S

IG

NE

D

BY

TH

E

AL

TE

RI

NG

A

RC

HI

TE

CT

IN

A

CC

OR

DA

NC

E

W

ITH

TH

E

RE

QU

IR

EM

EN

TS

O F P

AR

T 6

9.5 b).

DATE:

JOB NO:

DRAWN BY:

SCALE:

N o rt h S al in a S tr ee t, S yr ac us e, N Y

PROJECT NORTH

/2

6/

0:

:3

AM

C

:\U se rs \lh un t\O ne D riv e

- H

KK

A ss oc ia te s Ar ch ite ct s\

D oc um en ts \R

_2

_S U

N Y

ES

F_

B ra y H al l_

C en tra l_ lh un t@ hk ka rc hi te ct s.

co m

.rv t

As indicated

ISSUED FOR PERMIT

A5.2

DETAILS

25013

UP

GR

AD

E

EX

TE

RI

OR

D

OO

RS

S

EC

UR

IT

Y B

R A

Y H

A

LL

; S U

N Y

E

SF

10/26/26

Author

SU

N

Y E

SF

C

A M

PU

S, S Y

R A

C U

SE

, N

EW

Y

O R

K

SCALE: 3/4" = 1'-0"SCALE: 3/4" = 1'-0" A5.2A5.2

A-1A-1INTERIOR ELEVATION AT STAIRINTERIOR ELEVATION AT STAIR

SCALE: 1/2" = 1'-0"SCALE: 1/2" = 1'-0" A5.2A5.2

B-1B-1INTERIOR ELEVATION AT EAST ENTRYINTERIOR ELEVATION AT EAST ENTRY

SCALE: 1" = 1'-0"SCALE: 1" = 1'-0" A5.2A5.2

A-2A-2LOWER DOOR PLAN DETAILLOWER DOOR PLAN DETAIL

SCALE: 1" = 1'-0"SCALE: 1" = 1'-0" A5.2A5.2

C-2C-2DOOR TRANSOM DETAILDOOR TRANSOM DETAIL

SCALE: 1" = 1'-0"SCALE: 1" = 1'-0" A5.2A5.2

B-2B-2DOOR PANEL PLAN DETAILDOOR PANEL PLAN DETAIL

SCALE: 6" = 1'-0"SCALE: 6" = 1'-0" A5.2A5.2

D-3D-3TRANSOM HEAD DETAILTRANSOM HEAD DETAIL

SCALE: 6" = 1'-0"SCALE: 6" = 1'-0" A5.2A5.2

D-2D-2TRANSOM JAMB DETAILTRANSOM JAMB DETAIL

SCALE: 3" = 1'-0"SCALE: 3" = 1'-0" A5.2A5.2

A-3A-3HEAD DETAIL AT NORTH/SOUTH DOORHEAD DETAIL AT NORTH/SOUTH DOOR

REV.

A5.3 A-2

A5.3 A-3

A5.3 B-2

8'

0" 6'

2"

1/4" 1" 3 1/4"

1/8"

2 1/4" 2 3/4"

3/4"

2 1/4"

1/ 4"

3/ 4"

3/ 8"

1/ 2"

3/ 8" 3/ 8"

6"

1/ 4"

NEW CASING - SEE

B-1/A5.1

EXISTING INTERIOR FINISH

PLYWOOD FURRINGWOOD BLOCKING

NOTE: ALL EXPOSED WOOD

TO BE QUARTER SAWN

WHITE OAK - MATCH FINISH

OF WEST ENTRY.

A5.3 B-1

EXISTING CONCRETE

LANDING

5/8" GWB

5/8" PLYWOOD

2X6 @ 16" O.C.

A5.3 B-1

2'

1/

4"

1/

4"

1/2" 5/8" 5 1/2"

5/8"

5/8"

6"

1/ 4"

3/ 8"

3/ 4"

3/

4" 1'

1/ 4"

3/ 4"

3/

4"

1/ 2"

3/ 8"

5/ 8"

1/4"

3/4"

1/2" 3"

3 1/4"

3/8" 1/4"

3"

7/ 8"

3" 5/

8"

3/ 8"

3/ 4"

2 1/4"

3/8"

1" 1/8"

2 1/4" 2 3/8"

3/4"

2 7/8"

CASING TRIM

SEE B-1/A5.1

3/ 4"

1/

2" 7"

ALIGN

NOTE: ALL EXPOSED WOOD

TO BE QUARTER SAWN

WHITE OAK - MATCH FINISH

OF WEST ENTRY.

A5.3 B-1

5/8" 3/4"

7/8"

1'

1" 1'

4"

8"

1/ 2"

2 1/4"

5/8"

3/4"

7/8"

3/

8"

1/ 2"

/4

1/

2"

3/ 8"

5/8" 1" 5/8"

1 1/2"

QUARTER ROUND, BOTH

SIDES

NOTE: ALL EXPOSED WOOD

TO BE QUARTER SAWN

WHITE OAK - MATCH FINISH

OF WEST ENTRY.

1'

1" 1'

4"

8"

3/ 8"

2 1/4"

5/8"

3/4"

7/8"

1/2" HIGH THRESHOLD - APPLY SOLID

BEADS OF ADHESIVE TO

UNDERSIDE OF THRESHOLD

LEGS

3/

8"

1/ 2"

/4

1/

2"

3/ 8"

5/8" 1" 5/8"

1 1/2"

NOTE: ALL EXPOSED WOOD

TO BE QUARTER SAWN

WHITE OAK - MATCH FINISH

OF WEST ENTRY.

5/8" 3/4" 7/8"

1/

4"

3/ 8"

3/ 8"

3/ 8"

1/ 2"

/16

1/

4"

1/8" 1/8" 3/8" 1/4"

1/ 8"

1/ 8"

1/ 8"

1/ 4"

1"

1/ 4" 1/

8"

1/

4"

3/ 4"

3/ 4"2 1/

4"

1/4"

3/4" 3/8"

1/2"

3/8"

3/8"

6"1 1/4"

W O

O D

BL

O

CK

IN

G

EXISTING INTERIOR FINISH

PLYWOOD FURRING

NEW CASING - SEE B-1/A5.1

NOTE: ALL EXPOSED WOOD

TO BE QUARTER SAWN

WHITE OAK - MATCH FINISH

OF WEST ENTRY.

5/8" 3/4" 7/8"

3/

8"

3/ 8"

1/ 4"

3/ 8"

1/ 4"

1/ 4"

1/4" 1/4" 1/4"1/4"1/4"1/8"

P h

) 4

) 4 w w w .h kk ar ch ite ct s.c om

H O

LL

Q U

IS

T

As so cia tes , A rch ite cts , L

LP

ALL DRAWINGS AND SPECIFICATIONS ARE THE

PROPERTY OF THE ARCHITECT AND SHALL BE USED

ONLY ON THE JOB DESIGNATED. COPYRIGHT C

THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS

AT THE SITE AND PROMPTLY NOTIFY THE

ARCHITECT IN WRITING OF ANY DISCREPANCIES.

PA

RT

.5( b)

OF

TH

E

TIT

LE

V

III

ED

UC

AT

IO

N

LA

W O

F N

EW

Y

OR

K

PR

OH

IB

ITS

A

NY

A

ND

A

LL

A

LT

ER

AT

IO

NS

TO

TH

IS

D

RA

W

IN

G

OR

D

OC

UM

EN

T B Y

AN

Y

PE

RS

ON

, U

NL

ES

S

AC

TIN

G

UN

DE

R

TH

E

DI

RE

CT

IO

N

OF

A

LI

CE

NS

ED

A

RC

HI

TE

CT

. A

NY

S

UC

H

AL

TE

RA

TIO

NS

S

HA

LL

B E

NO

TE

D, S

EA

LE

D, A

ND

S

IG

NE

D

BY

TH

E

AL

TE

RI

NG

A

RC

HI

TE

CT

IN

A

CC

OR

DA

NC

E

W

ITH

TH

E

RE

QU

IR

EM

EN

TS

O F P

AR

T 6

9.5 b).

DATE:

JOB NO:

DRAWN BY:

SCALE:

N o rt h S al in a S tr ee t, S yr ac us e, N Y

PROJECT NORTH

/2

6/

0:

:3

AM

C

:\U se rs \lh un t\O ne D riv e

- H

KK

A ss oc ia te s Ar ch ite ct s\

D oc um en ts \R

_2

_S U

N Y

ES

F_

B ra y H al l_

C en tra l_ lh un t@ hk ka rc hi te ct s.

co m

.rv t

As indicated

ISSUED FOR PERMIT

A5.3

DETAILS

25013

UP

GR

AD

E

EX

TE

RI

OR

D

OO

RS

S

EC

UR

IT

Y B

R A

Y H

A

LL

; S U

N Y

E

SF

10/26/26

Author

SU

N

Y E

SF

C

A M

PU

S, S Y

R A

C U

SE

, N

EW

Y

O R

K

SCALE: 1" = 1'-0"SCALE: 1" = 1'-0" A5.3A5.3

A-1A-1SECTION THRU NORTH/SOUTH SIDELITESECTION THRU NORTH/SOUTH SIDELITE

SCALE: 3" = 1'-0"SCALE: 3" = 1'-0" A5.3A5.3

B-2B-2HEAD DETAIL AT NORTH/SOUTH SIDELITE TRANSOMHEAD DETAIL AT NORTH/SOUTH SIDELITE TRANSOM

SCALE: 3" = 1'-0"SCALE: 3" = 1'-0" A5.3A5.3

A-2A-2HEAD DETAIL AT NORTH/SOUTH SIDELITEHEAD DETAIL AT NORTH/SOUTH SIDELITE

SCALE: 3" = 1'-0"SCALE: 3" = 1'-0" A5.3A5.3

A-3A-3SECTION THRU BOTTOM OF NORTH/SOUTH SIDELITESECTION THRU BOTTOM OF NORTH/SOUTH SIDELITE

SCALE: 3" = 1'-0"SCALE: 3" = 1'-0" A5.3A5.3

A-4A-4SECTION THRU BOTTOM OF NORTH/SOUTH DOORSECTION THRU BOTTOM OF NORTH/SOUTH DOOR

SCALE: 12" = 1'-0"SCALE: 12" = 1'-0" A5.3A5.3

B-1B-1MUNTIN DETAILMUNTIN DETAIL

SCALE: 3" = 1'-0"SCALE: 3" = 1'-0" A5.3A5.3

B-3B-3JAMB DETAIL AT NORTH/SOUTH SIDELITE TRANSOMJAMB DETAIL AT NORTH/SOUTH SIDELITE TRANSOM

SCALE: 12" = 1'-0"SCALE: 12" = 1'-0" A5.3A5.3

B-4B-4GLAZING STOP DETAILGLAZING STOP DETAIL

REV.

LEGEND - DOOR TYPES

DOOR TYPE A DOOR TYPE B DOOR TYPE C

9'

0"

3' - 0"

7'

0"

1'

6" 3'

3"

6"

6" 2' - 4" 6"

3' - 4"

3' - 3"

5 1/4" 5 1/4"2' - 4 1/2"

8'

0"

7" 4'

4"

8" 1'

4"

1'

1"

11' - 0 7/8" (VIF)

/4

V

IF

9' - 6" (VIF)

1' - 8 5/8"6' - 1 5/8"1' - 7 7/8"

9'

3" (V

IF

/8

(V

IF

11' - 0 7/8" (VIF)

LEGEND - DOOR FRAME

EXISTING PARTITION

TO REMAIN

DRYWALL F REVEAL

BOTH SIDES

ALUMINUM

STOREFRONT

1/4" SHIM

SEALANT

3/4" BLOCKING

DRYWALL F REVEAL

BOTH SIDES

EXISTING WALL TO REMAIN

3/4" BLOCKING

ALUMINUM

STOREFRONT 1/4" SHIM SPACE

SEALANT

EXISTING WALL TO

REMAIN

DRYWALL F REVEAL

1/4" SHIM

SEALANT

BACKER ROD &

SEALANT

ALUMINUM

STOREFRONT

EXISTING BRICK

EXISTING WOOD STUD

FRAMING

DRYWALL F REVEAL

BOTH SIDES

EXISTING WALL TO REMAIN

3/4" BLOCKING

ALUMINUM

STOREFRONT

1/4" SHIM SPACE

BACKER ROD &

SEALANT

EXISTING SOFFIT

P h

) 4

) 4 w w w .h kk ar ch ite ct s.c om

H O

LL

Q U

IS

T

As so cia tes , A rch ite cts , L

LP

ALL DRAWINGS AND SPECIFICATIONS ARE THE

PROPERTY OF THE ARCHITECT AND SHALL BE USED

ONLY ON THE JOB DESIGNATED. COPYRIGHT C

THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS

AT THE SITE AND PROMPTLY NOTIFY THE

ARCHITECT IN WRITING OF ANY DISCREPANCIES.

PA

RT

.5( b)

OF

TH

E

TIT

LE

V

III

ED

UC

AT

IO

N

LA

W O

F N

EW

Y

OR

K

PR

OH

IB

ITS

A

NY

A

ND

A

LL

A

LT

ER

AT

IO

NS

TO

TH

IS

D

RA

W

IN

G

OR

D

OC

UM

EN

T B Y

AN

Y

PE

RS

ON

, U

NL

ES

S

AC

TIN

G

UN

DE

R

TH

E

DI

RE

CT

IO

N

OF

A

LI

CE

NS

ED

A

RC

HI

TE

CT

. A

NY

S

UC

H

AL

TE

RA

TIO

NS

S

HA

LL

B E

NO

TE

D, S

EA

LE

D, A

ND

S

IG

NE

D

BY

TH

E

AL

TE

RI

NG

A

RC

HI

TE

CT

IN

A

CC

OR

DA

NC

E

W

ITH

TH

E

RE

QU

IR

EM

EN

TS

O F P

AR

T 6

9.5 b).

DATE:

JOB NO:

DRAWN BY:

SCALE:

N o rt h S al in a S tr ee t, S yr ac us e, N Y

PROJECT NORTH

/2

6/

0:

:3

AM

C

:\U se rs \lh un t\O ne D riv e

- H

KK

A ss oc ia te s Ar ch ite ct s\

D oc um en ts \R

_2

_S U

N Y

ES

F_

B ra y H al l_

C en tra l_ lh un t@ hk ka rc hi te ct s.

co m

.rv t

As indicated

ISSUED FOR PERMIT

A7.1

DOOR SCHEDULE

25013

UP

GR

AD

E

EX

TE

RI

OR

D

OO

RS

S

EC

UR

IT

Y B

R A

Y H

A

LL

; S U

N Y

E

SF

10/26/26

LAH

SU

N

Y E

SF

C

A M

PU

S, S Y

R A

C U

SE

, N

EW

Y

O R

K

SCALE: 1/2" = 1'-0"SCALE: 1/2" = 1'-0"

LEGEND - DOOR TYPESLEGEND - DOOR TYPES

DOOR SCHEDULE

DOOR

MARK

DOOR PANEL FRAME FIRE

LABEL LINTEL

HARD-

WARE THRESH REMARKSTYPE MAT W H THK FIN COL TYPE HEAD JAMB MAT FIN COL

G01 A AL 3' - 4" 7' - 3" 2" - A B-3/A7.1 A-3/A7.1 AL - - - 4 AL

G02 A AL 3' - 4" 7' - 0" 2" - A B-2/A7.1 A-2/A7.1 AL - - - 5 AL

101A EX WD 6' - 2

1/2"

8' - 0" 2" STN - EX - - - 1 AL

101B C GL 6' - 1" 9' - 0 7/8" 1/2" - SF1B - - - - 2 -

101C EX WD 6' - 2

1/2"

8' - 0" 2" STN - EX - - - -

101D EX WD 6' - 2

1/2"

8' - 0" 2" STN - EX - - - -

103 B WD 6' - 8" 8' - 0" 2 1/4" STN A B-3/A5.3 A-1/A5.2 WD STN - - 3 AL

104 B WD 6' - 8" 8' - 0" 2 1/4" STN A B-2/A5.3 A-1/A5.2 WD STN - - 3 AL

SF1CSF1BSF1A

SCALE: 1/4" = 1'-0"SCALE: 1/4" = 1'-0"

LEGEND - DOOR FRAMELEGEND - DOOR FRAME

SCALE: 3" = 1'-0"SCALE: 3" = 1'-0" A7.1A7.1

A-2A-2JAMB DETAIL AT DOOR G02JAMB DETAIL AT DOOR G02

SCALE: 3" = 1'-0"SCALE: 3" = 1'-0" A7.1A7.1

B-2B-2HEAD DETAIL AT DOOR G02HEAD DETAIL AT DOOR G02

A-1

A7.1SCALE: 3" = 1'-0"SCALE: 3" = 1'-0" A7.1A7.1

A-3A-3JAMB DETAIL AT DOOR G01JAMB DETAIL AT DOOR G01

SCALE: 3" = 1'-0"SCALE: 3" = 1'-0" A7.1A7.1

B-3B-3HEAD DETAIL AT DOOR G01HEAD DETAIL AT DOOR G01

REV.

ISSUE:

DATE:

DRAWN BY:

CHECKED BY:

SCALE:

PROJECT NO.

SHEET TITLE

SHEET

DRAWING NO.

ALTERATION OF THIS DOCUMENT

EXCEPT BY A LICENSED DESIGN

PROFESSIONAL, IS A VIOLATION OF

NEW YORK STATE EDUCATIONAL LAW.

OF

FS ENGINEERING,

DPC

721 E. Genesee Street Syracuse, NY 13210 Tel: 315-471-4013 Fax: 315-471-4044

E n te r a d d re s s h e re

R R e v it M

E P

\T e m p la te s \S

A

M e c h a n ic a l.

rt e

/5

/2

:1 :2

P

M

O w n e r

P ro je c t

N a m e

SK-M2

01/01/2019

Author

Checker

Project Number

Unnamed

MARK DATE DESCRIPTION

14/10 RECTANGULAR DUCT (SIZE IN INCHES)

ROUND DUCT (DIAMETER IN INCHES)14Ø

AUTOMATIC AIR DAMPER

VOLUME DAMPER

SMOKE DAMPER

FIRE DAMPER

SD

VD

FD

SYMBOL DESCRIPTION

AAD

DUCTWORK SYMBOLS & ABBREVIATIONS

FIRE SMOKE DAMPERFSD

DUCT SMOKE DETECTOR (FURNISHED & WIRED BY DIV 28, MOUNTED

BY DIV 23. INSTALL PER MANUFACTURER'S INSTRUCTIONS)

DSD

OVAL DUCT (SIZE IN INCHES)14/10Ø

LOW VELOCITY DUCTWORK SYMBOLS

SINGLE LINE DOUBLE LINEDESCRIPTION

DIRECTION OF FLOW

DUCT SIZE, FIRST FIGURE IS

SIZE SHOWN 12/20

12/20

SUPPLY DUCT SECTION

(POSITIVE) PRESSURE,

FIRST FIGURE IS TOP

20/12 20/12

RETURN / EXHAUST DUCT

SECTION

20/12 20/12

ROUND SIDE TAP WITH

VOLUME DAMPER (UNLESS

OTHERWISE NOTED)

90° BRANCH

TAKE OFF

(45° ENTRY TYPE FOR

RECTANGULAR DUCT) 1-1/4A)XB

(MIN)

VD

VD

AxB 4"

(MIN)

45°

VD

VD

VD

DUAL 90°

BRANCH TAKE

OFF

(45° ENTRY TYPE)

FLEXIBLE DUCT

FLEX CONNECTION

ACCESS DOOR AD

AD

GRILLE REGISTER

OR DIFFUSER IN

BOTTOM OF DUCT

DUCT

ELBOW UP

OR DOWN

TURN UP

TURN DOWN

12x6

TURN DOWN

12x6

TURN UP

OR

LONG RADIUS 90 DEGREE

ELBOW OR TURNING

VANES

TRANSITION:

LOCATION OF TRANS. IS

DIAGRAMMATICAL

CONTRACTOR MAY EXTEND

LENGTH OF LARGER DUCT

TO ACCOMMODATE STD.

LENGTH DUCT SECTIONS.

CONTRACTOR'S

OPTION

AS SHOWN

90 DEGREE BRANCH

TAKEOFF FROM

VERTICAL DUCT-45

DEGREE ENTRY TYPE

ELEV.

PLANPLAN

ELEV.

DUCT RISE / DROP TO

AVOID OBSTRUCTION

ARROW INDICATES AIR

FLOW DIRECTION

90° BRANCH TAKE OFF

(TEE TYPE

FOR ROUND DUCT)

RISE

R D

DROP RISE

UP DN

DROP

VDVD

RETURN / EXHAUST DUCT

PENETRATION OF FLOOR

OR ROOF ABOVE. SEE

PLANS FOR DAMPER

REQUIREMENTS

SUPPLY DUCT

PENETRATION OF FLOOR

OR ROOF ABOVE. SEE

PLANS FOR DAMPER

REQUIREMENTS

ACOUSTICALLY LINED DUCT

(DUCT DIMENSIONS

INDICATE INSIDE CLEAR

DIMENSION)

OR

MECHANICAL PIPING SYMBOLS & ABBREVIATIONS

SHUTOFF VALVE (REFER TO SPECIFICATIONS FOR SPECIFIC TYPE)

CHECK VALVE

BUTTERFLY VALVE

BALL VALVE

PETCOCK

CALIBRATED BALANCING VALVE

UNION

PRESSURE GAUGE (WITH VALVE)

TEMPERATURE SENSOR

DRAIN VALVE WITH CAPPED AND CHAINED HOSE END

PIPE UP / PIPE DOWN (ELBOW)

BRANCH CONNECTION - UP / DOWN

CONCENTRIC REDUCER

PIPING (ARROW INDICATES DIRECTION OF FLOW)

PIPE ANCHOR

PIPE GUIDE

GLOBE VALVE

PIPE CAP

PITCH OF PIPE

STRAINER W/ BLOW OFF

STRAINER

MV AV

PRESSURE RELIEF VALVE

TEMPERATURE WELL

THERMOMETER

TRIPLE DUTY VALVE

CONDENSATE "P"-TRAP

DNUP

PS

FS

PRESSURE SWITCH

FLOW SWITCH

EXPANSION JOINT

PRESSURE REDUCING REGULATOR VALVE

T

GATE VALVE

2-WAY CONTROL VALVE

3-WAY CONTROL VALVE

MANUAL AIR VENT / AUTOMATIC AIR VENT

SYMBOL DESCRIPTION

SPECIFIC SHUTOFF VALVE TYPES:

SUPPLY DIFFUSER PLAN SYMBOL EXPLANATION:

CFM

SUPPLY AIR DIFFUSER (NOMINAL 2' x 2')

SUPPLY DIFFUSER TYPE (SEE SCHEDULE)

RETURN / EXHAUST AIR REGISTER

CFM

SL8

REGISTER/GRILLE PLAN SYMBOL EXPLANATION:

CFM (E = EXHAUST / R = RETURN)

REGISTER/GRILLE TYPE (SEE SCHEDULE)

CFM

RE10

SYMBOL DESCRIPTION

GRILLE, REGISTER & DIFFUSER SYMBOLS

LINEAR SLOT DIFFUSER WITH DISTRIBUTION PLENUM

REGISTER AND DIFFUSER AIR FLOW PATTERNS

4-WAY BLOW 3-WAY BLOW 2-WAY BLOW

DUCTWORK EXISTING TO REMAIN IN THIS CONTRACT OR ACTIVE

PHASE OF CONTRACT

DUCTWORK REMOVED IN THIS CONTRACT OR ACTIVE PHASE

OF CONTRACT

POINT OF CONNECTION - NEW TO EXISTING

POINT OF REMOVAL - DEMOLITION TO EXISTING

DEDICATED ELECTRICAL AREA - NO MECHANICAL WORK

ALLOWED IN OR ABOVE HIGHLIGHTED AREA UNLESS

SPECIFICALLY NOTED OTHERWISE

PIPE REMOVED IN THIS CONTRACT OR ACTIVE PHASE OF

CONTRACT

PIPE EXISTING TO REMAIN IN THIS CONTRACT OR ACTIVE PHASE

OF CONTRACT

SYS (E)

SYSTEM NAME

(E) = EXIST TO REMAIN, (D) = EXIST TO BE REMOVED

DUCTWORK PROVIDED IN THIS CONTRACT OR ACTIVE PHASE

OF CONTRACT

PIPE PROVIDED IN THIS CONTRACT OR ACTIVE PHASE OF

CONTRACT

SYS (D)

SYS

SYS (D)

SYS

(10x6) SYS (E)

(10) SYS (E)

DEMOLITION KEYED NOTE

KEYED NOTE

SYSTEM PHASING SYMBOLS

M#

MD#

PLAN DETAIL

BUILDING SECTION

DETAIL

NUMBER

SHEET

NUMBER

WHERE DETAIL

IS LOCATED

DETAIL

NUMBER

SHEET

NUMBER

WHERE DETAIL

IS LOCATED

EXTENT OF

DETAIL

EXTENT OF

DETAIL

A1

B1

C1

D1

E1

A2

B2

C2

D2

E2

A3

B3

C3

D3

E3

A4

B4

C4

D4

E4

A5

B5

C5

D5

E5

A6

B6

C6

D6

E6

DETAIL NUMBER

DETAIL SCALE

DETAIL NAME

DETAIL

NUMBER

PLAN SETUP

SHEET

NUMBER

WHERE DETAIL

IS LOCATED

CAUTION: THESE DOCUMENTS WERE DIGITALLY PRODUCED AND/OR REPRODUCED.

CONFIRM REDUCTION OR MAGNIFICATION USING DIMENSIONAL 3"-LONG LINE IN TITLE

BARS. IF SCALING DRAWINGS FOR APPROXIMATE DIMENSIONS, ALTERNATE

ARCHITECTURAL SCALES MAY BE USED AS FOLLOWS:

DOCUMENT REDUCTION/MAGNIFICATION SCALE

IF LINE MEASURES 2” (67% COPY):

USE 3/16th SCALE ON 1/8”=1’-0” DWG USE 3/8th SCALE ON 1/4”=1’-0” DWG

IF LINE MEASURES 1.5” (50% COPY):

USE 1/16th SCALE ON 1/8”=1’-0” DWG USE 1/8th SCALE ON 1/4”=1’-0” DWG

3"

3"

? XXX

X" = X"

CO2

CO

SP

T/H

TS

T

CARBON DIOXIDE SENSOR

CARBON MONOXIDE SENSOR

STATIC PRESSURE SENSOR

TEMPERATURE SENSOR

TEMPERATURE/HUMIDITY SENSOR

THERMOSTAT

C = COMMUNICATION PORT

N = NIGHT SETBACK

P = PNEUMATIC

G = LOCKING GUARD COVER

Z = ZONE

H HUMIDITY SENSOR

TEMPERATURE CONTROLS ABBREVIATIONS

SYMBOL DESCRIPTION

FS ENGINEERING, DPC

721 E. Genesee Street Syracuse, NY 13210

Tel: 315-471-4013 Fax: 315-471-4044

FS#26022

P h

(3 a x

(3 w w w .h k k a rc h it ec ts

.c o m

H O

L M

E S

L L

Q U

IS

T

A ss oc ia te s, A rc hi te ct s, L

L P

ALL DRAWINGS AND SPECIFICATIONS ARE THE

PROPERTY OF THE ARCHITECT AND SHALL BE USED

ONLY ON THE JOB DESIGNATED. COPYRIGHT C

THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS

AT THE SITE AND PROMPTLY NOTIFY THE

ARCHITECT IN WRITING OF ANY DISCREPANCIES.

P A

R T

.5

(b ) O

F

TH

E T

IT

LE

V

III

E D

U C

A

TI

O N

L A

W O

F N

E W

Y O

R K

P R

O H

IB

IT

S A

N Y

A N

D A

LL

A

LT

E

R A

TI

O

N S

T O

T H

IS

D

R A

W

IN

G O

R D

O C

U M

E N

T B

Y A

N Y

P E

R S

O N

, U N

LE

S

S A

C

TI

N G

U N

D E

R T

H E

D

IR

E C

TI

O

N O

F A

L

IC

E N

S E

D A

R C

H

IT

E C

T.

A

N Y

S U

C H

A

LT

E R

A

TI

O N

S S

H A

LL

B

E N

O

TE

D , S

E A

LE

D

, A N

D S

IG

N

E D

B Y

T H

E A

LT

E

R

IN

G A

R C

H

IT

E C

T

IN

A C

C O

R D

A N

C E

W

IT

H T

H E

R E

Q U

IR

E

M E

N

TS

O F

P A

R T

.5

(b

DATE:

JOB NO:

DRAWN BY:

SCALE:

N o r t h

S a l in a S t r e e t

S y r a c u s e

N

Y

PROJECT NORTH

I, THE UNDERSIGND ARCHITECT, CERTIFY

THAT TO THE BEST OF MY KNOWLEDGE,

INFORMATION, AND BELIEF, THE PLANS AND

SPECIFICATIONS ARE IN ACCORDANCE WITH

APPLICABLE REQUIREMENTS OF THE

AND THE

INTERNATIONAL BUILDING CODE

AS ADOPTED BY NEW YORK STATE

INTERNATIONAL ENERGY CONSERVATION CODE

AS ADOPTED BY NEW YORK STATE

ISSUE DATE

BID SET No.

/2

/2

:3

:5

P M

A u to d e s k D o c s /2

S

U N

Y E

S F

B ra y H a ll

E x te ri o r

D o o rs a n d

S e c u ri ty

/2

S

U N

Y E

S F

B ra y H a ll_

M E

P R

.r v t

As indicated

ISSUED FOR PERMIT

M001

DRAWING INDEX,

SYMBOLS &

ABBREVS.

25013

U P

G R

A D

E E

X T

E R

IO

R

D O

O R

S

S E

C U

R

IT

Y B

R A

Y H

A L

L

S U

N Y

E S

F

10/26/26

JMR

S U

N Y

E S

F C

A M

P U

S

S Y

R A

C U

S E

N

E W

Y O

R K

MECHANICAL DRAWING INDEX

NUMBER NAME

REVISIONS

# DATE

M001 DRAWING INDEX, SYMBOLS & ABBREVS.

M101 FLOOR PLAN, SCHEDULE, AND SEQUENCES

GENERAL MECHANICAL NOTES

A REFER TO ARCHITECTURAL DRAWINGS FOR CEILING GRID WORK PREFORMED

BY OTHERS. IF NOT SHOWN ELSEWHERE INCLUDE IN THIS DIVISIONS WORK AS

REQUIRED.

B WHERE WORK ISN'T SHOWN BY OTHERS, HVAC CONTRACTOR SHALL REMOVE,

STORE, AND REINSTALL EXISTING LAY-IN CEILING TILES & TEES AS REQUIRED

FOR ALL WORK SHOWN. REPLACE ANY DAMAGED CEILING TILES AND CEILING

SUPPORT GRID SYSTEM.

C COORDINATE LEFT OR RIGHT UNIT CONNECTION ORIENTATION.

D INSTALL UNIT TO ALLOW FOR MAINTENANCE ACCESS TO FILTERS, VALVES,

CONTROLS, LUBRICATION POINTS.

E HIRE OWNER APPROVED ROOFING CONTRACTOR AS TO NOT VOID ROOF

WARRANTY.

F FIELD VERIFY EXISTING CONDITIONS, AND REPORT DISCREPANCIES TO THE

ARCHITECT / ENGINEER AND AWAIT CLARIFICATION PRIOR TO PROCEEDING

WITH REMOVAL AND RENOVATION WORK.

AAV AIR ADMITTANCE VALVE

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

BFF BELOW FINISHED FLOOR

BFG BELOW FINISHED GRADE

BOS BOTTOM OF STEEL

BTUH BRITISH THERMAL UNIT PER

HOUR

CFM CUBIC FEET PER MINUTE

CO CLEANOUT

COP COEFFICIENT OF

PERFORMANCE

DB DRY BULB

DIA. DIAMETER

°F DEGREES FARENHEIT

EA EXHAUST AIR

EAT ENTERING AIR TEMPERATURE

EFF. EFFICIENCY

ELEC. CONTRACTOR FOR ELECTRICAL

DIVISION

EWT ENTERING WATER

TEMPERATURE

EXT EXISTING

EXT. PD EXTERNAL PRESSURE DROP

FF FINISHED FLOOR

FL FAIL LAST

FLA FULL LOAD AMPACITY

FLR FLOOR

FP CONTRACTOR FOR FIRE

PROTECTION

FPM FEET PER MINUTE

FS FLOW SWITCH

FSD FIRE / SMOKE DAMPER

FT FEET

FT-HD FEET OF HEAD (PRESSURE)

GC CONTRACTOR FOR GENERAL

CONSTRUCTION DIVISION

GPM GALLONS PER MINUTE

GRD GRILLES, REGISTERS,

DIFFUSERS

HGT HEIGHT

HP HORSEPOWER

HVAC CONTRACTOR FOR HEATING,

VENTILATING & AIR

CONDITIONING DIVISION

IN-WC INCHES OF WATER COLUMN

(PRESSURE)

IN. INCH HVAC DUCT SYSTEM ABBREVIATIONS

ABBREV. DESCRIPTION

HVAC PIPE SYSTEM ABBREVIATIONS

ABBREV. DESCRIPTION

HVAC EQUIPMENT ABBREVIATIONS

ABBREV. DESCRIPTION

FTR-A

GENERAL ABBREVIATIONS

TO THE BEST OF THE ENGINEER'S PROFESSIONAL JUDGEMENT, THE DESIGN OF THIS

PROJECT CONFORMS TO ALL APPLICABLE PORTIONS OF THE FOLLOWING:

THE 2025 NEW YORK STATE UNIFORM FIRE PREVENTION AND BUILDING CODE

THE 2025 NEW YORK STATE ENERGY CONSERVATION CONSTRUCTION CODE, 2025

ASHRAE 90.1, AND 2007 ASHRAE 183; FOLLOWING THE COMPLIANCE PATH MARKED

BELOW:

NYS ANSI / ASHRAE / IES 90.1, AS AMENDED BY 19 NYCRR PART 1240 AND

ADDITIONAL ENERGY EFFICIENCY REQUIREMENTS IN SECTION C11 AS

APPLICABLE:

ADDITIONAL ENERGY EFFICIENCY CREDITS APPLICABLE. SEE CREDIT

SCORECARD FOR OPTIONS SELECTED.

ECCCNYS CHAPTER 4 [CE] PRESCRIPTIVE PROVISIONS (SECTIONS C402, C403,

C404, C405, C408 AND ADDITIONAL ENERGY EFFICIENCY REQUIREMENTS IN

SECTION C406 AS APPLICABLE:

ADDITIONAL ENERGY EFFICIENCY CREDITS APPLICABLE. SEE CREDIT

SCORECARD FOR OPTIONS SELECTED.

SIMULATED PERFORMANCE PROVISIONS (SECTION C407)

THE NEW YORK STATE EDUCATION DEPARTMENT ("SED") MANUAL OF PLANNING

STANDARDS

THE 2014 FGI GUIDELINES FOR DESIGN AND CONSTRUCTION OF HOSPITALS AND

OUTPATIENT FACILITIES

THE 2018 FGI GUIDELINES FOR DESIGN AND CONSTRUCTION OF:

HOSPITALS INCLUDING ASHRAE 170-2021

OUTPATIENT FACILITIES INCLUDING ASHRAE 170-2021

RESIDENTIAL HEALTH, CARE, AND SUPPORT FACILITIES INCLUDING ASHRAE

170-2021

ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED

HEATING

COOLING

SUMMER

WINTER

COUNTY / CLIMATE ZONE

HVAC DESIGN CRITERIA

INTERIOR DESIGN CONDITIONS

OUTDOOR DESIGN CONDITIONS

DESIGN LOADS HAVE BEEN DETERMINED IN ACCORDANCE WITH THE PROCEDURES

DESCRIBED IN ANSI / ASHRAE / ACCA STANDARD 183

72°F DB

75°F DB

-3°F DB

ONONDAGA / 5

88°F DB / 72°F WB

GENERAL ROOFING NOTES

1 FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS AND NOTIFY

ARCHITECT IN WRITING WITHIN 24 HOURS OF DISCOVERY OF ANY

DISCREPANCIES.

2 CURBS SHALL HAVE FLASHING HEIGHT OF14" MINIMUM ABOVE THE PROPOSED

ROOF MEMBRANE. PROVIDE CURB EXTENSIONS OR RESET UNITS WITH WOOD

BLOCKING TO MATCH HEIGHT OF PROPOSED INSULATION WHERE INDICATED.

3 ALL ROOF PENETRATIONS ARE EXISTING UNLESS OTHERWISE INDICATED.

4 TEMPORARILY DISCONNECT AND RE-CONNECT ALL UTILITIES AND SERVICES

NECESSARY FOR INSTALLATION OF NEW ROOF OR FOR DEMOLITION

PURPOSES NOT INDICATED UNDER OTHER CONTRACTS. BUILDING UTILITIES

MAY NOT BE INTERRUPTED AT ANY TIME DURING THIS PROJECT.

5 ESTABLISH AND MAINTAIN WATERTIGHT CONDITION AT ALL ROOF AREAS AT

ALL TIMES THROUGH DURATION OF WORK.

LAT LEAVING AIR TEMPERATURE

LWT LEAVING WATER

TEMPERATURE

MAX. MAXIMUM

MBH 1,000 BTUH

MCA MINIMUM CIRCUIT AMPACITY

MGAP MEDICAL GAS ALARM PANEL

MIN. MINIMUM

MOCP MAXIMUM OVERCURRENT

PROTECTION

MTD MOUNTED

NC NORMALLY CLOSED

NIC NOT IN CONTRACT

NO NORMALLY OPEN

NOM. NOMINAL

NTS NOT TO SCALE

OA OUTSIDE AIR

OAI OUTDOOR AIR INTAKE

OED OPEN-END DUCT

PD PRESSURE DROP

PH PHASE

PLBG. CONTRACTOR FOR PLUMBING

DIVISION

PRV PRESSURE REDUCING VALVE

PS PRESSURE SWITCH / SENSOR

PSI POUNDS PER SQUARE INCH

RA RETURN AIR

RH RELATIVE HUMIDITY

RV RELIEF VALVE

SA SUPPLY AIR

SENS. SENSIBLE

SPL SOUND PRESSURE LEVEL

SWL SOUND POWER LEVEL

TA TRANSFER AIR

TC TEMPERATURE CONTROLS

CONTRACTOR

TDV TRIPLE DUTY VALVE

TOS TOP OF STEEL

TS TAMPER SWITCH

UH UNIT HEATER

UNO UNLESS NOTED OTHERWISE

UVC ULTRAVIOLET LIGHT

VRA VENTILATION RELIEF AIR

VRS VENTILATION SUPPLY AIR

WB WET BULB

ZVB ZONE VALVE BOX

REV.

NO.:

DATE:

DRAWN

BY:

DESCRIPTION:

T

Space

VESTIBULE

FTR-A

FTR-A

M2

M1 M1

M1 M1M3 M3

WORK AREA -

SOUTH

WORK AREA -

NORTH

WORK AREA -

WEST

FS ENGINEERING, DPC

721 E. Genesee Street Syracuse, NY 13210

Tel: 315-471-4013 Fax: 315-471-4044

FS#26022

P h

(3 x

(3 w w w .h k k a rc h it ec ts

.c o m

H O

L M

L L

Q U

IS

T

A ss oc ia te s, A rc hi te ct s, L

L P

ALL DRAWINGS AND SPECIFICATIONS ARE THE

PROPERTY OF THE ARCHITECT AND SHALL BE USED

ONLY ON THE JOB DESIGNATED. COPYRIGHT C

THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS

AT THE SITE AND PROMPTLY NOTIFY THE

ARCHITECT IN WRITING OF ANY DISCREPANCIES.

P A

R T

.5

(b ) O

F

TH

E T

IT

LE

V

III

E D

U C

A

TI

O N

L A

W O

F N

E W

Y O

R K

P R

O H

IB

IT

S A

N Y

A N

D A

LL

A

LT

E

R A

TI

O

N S

T O

T H

IS

D

R A

W

IN

G O

R D

O C

U M

E N

T B

Y A

N Y

P E

R S

O N

, U N

LE

S

S A

C

TI

N G

U N

D E

R T

H E

D

IR

E C

TI

O

N O

F A

L

IC

E N

S E

D A

R C

H

IT

E C

T.

A

N Y

S U

C H

A

LT

E R

A

TI

O N

S S

H A

LL

B

E N

O

TE

D , S

E A

LE

D

, A N

D S

IG

N

E D

B Y

T H

E A

LT

E

R

IN

G A

R C

H

IT

E C

T

IN

A C

C O

R D

A N

C E

W

IT

H T

H E

R E

Q U

IR

E

M E

N

TS

O F

P A

R T

.5

(b

DATE:

JOB NO:

DRAWN BY:

SCALE:

N o r t h

S a l in a S t r e e t

S y r a c u s e

N

Y

PROJECT NORTH

I, THE UNDERSIGND ARCHITECT, CERTIFY

THAT TO THE BEST OF MY KNOWLEDGE,

INFORMATION, AND BELIEF, THE PLANS AND

SPECIFICATIONS ARE IN ACCORDANCE WITH

APPLICABLE REQUIREMENTS OF THE

AND THE

INTERNATIONAL BUILDING CODE

AS ADOPTED BY NEW YORK STATE

INTERNATIONAL ENERGY CONSERVATION CODE

AS ADOPTED BY NEW YORK STATE

ISSUE DATE

BID SET No.

/2

/2

:3

:5

P M

A u to d e s k D o c s /2

S

U N

Y E

S F

B ra y H a ll

E x te ri o r

D o o rs a n d

S e c u ri ty

/2

S

U N

Y E

S F

B ra y H a ll_

M E

P R

.r v t

As indicated

ISSUED FOR PERMIT

M101

FLOOR PLAN,

SCHEDULE, AND

SEQUENCES

25013

U P

G R

A D

E E

X T

E R

IO

R

D O

O R

S

S E

C U

R

IT

Y B

R A

Y H

A L

L

S U

N Y

E S

F

10/26/26

JMR

S U

N Y

E S

F C

A M

P U

S

S Y

R A

C U

S E

N

E W

Y O

R K

3"SCALE: 1/4" = 1'-0"M101

2 FIRST FLOOR - WORK AREA WEST

MECHANICAL KEYED NOTES

M1 PROVIDE 17"W X 48"H ELECTRIC RADIATION PANEL.

M2 SPACE TEMPERATURE SENSOR SHALL BE INTERFACED WITH EXISTING BUILDING BMS SYSTEM

TO ENERGIZE/DE-ENERGIZE ALL FOUR HEATERS SIMULTANEOUSLY.

M3 REMOVE EXISTING INSULATION FROM EXPOSED HEATING PIPING AND PROVIDE NEW INSULATION

WITH PVC COVER.

3"SCALE: 1" = 40'-0"M101

4 FIRST FLOOR KEY PLAN

ELECTRIC RADIATOR SCHEDULE

UNIT NO. BTUH OUTPUT WATT OUTPUT VOLTAGE PHASE ELEMENT

ENCLOSURE MOUNTING

MANUFACTURER MODEL NOTES

WIDTH (IN) HEIGHT (IN) ARRANGEMENT BOTTOM AFF (IN)

FTR-A 4026 1180.0 208 1 VERTICAL 17 48" WALL 12" RUNTAL EWP-6

ELECTRIC RADIATOR CONTROL SEQUENCE

1 SPACE TEMPERATURE SET-POINT SHALL BE (75F ADJUSTABLE).

2 ELECTRIC RADIATORS SHALL BE CONTROLLED BY THE EXISTING BUILDING BMS SYSTEM.

3 UPON A CALL FOR HEAT, THE WALL MOUNTED TEMPERATURE SENSOR SHALL SEND A SIGNAL TO

THE BMS SYSTEM TO ENERGIZE ALL FOUR ELECTRIC RADIATORS.

4 ONCE VESTIBULE HEATING SET-POINT IS REACHED, RADIATORS SHALL BE DE-ENERGIZED.

REV.

NO.:

DATE:

DRAWN

ISSUE:

DATE:

DRAWN BY:

CHECKED BY:

SCALE:

PROJECT NO.

SHEET TITLE

SHEET

DRAWING NO.

ALTERATION OF THIS DOCUMENT

EXCEPT BY A LICENSED DESIGN

PROFESSIONAL, IS A VIOLATION OF

NEW YORK STATE EDUCATIONAL LAW.

OF

FS ENGINEERING,

DPC

721 E. Genesee Street Syracuse, NY 13210 Tel: 315-471-4013 Fax: 315-471-4044

E n te r a d d re s s h e re

R R e v it M

E P

\T e m p la te s \S

A

M e c h a n ic a l.

rt e

/5

/2

:1 :2

P

M

O w n e r

P ro je c t

N a m e

SK-M2

01/01/2019

Author

Checker

Project Number

Unnamed

MARK DATE DESCRIPTION

PLAN DETAIL

BUILDING SECTION

DETAIL

NUMBER

SHEET

NUMBER

WHERE DETAIL

IS LOCATED

DETAIL

NUMBER

SHEET

NUMBER

WHERE DETAIL

IS LOCATED

EXTENT OF

DETAIL

EXTENT OF

DETAIL

A1

B1

C1

D1

E1

A2

B2

C2

D2

E2

A3

B3

C3

D3

E3

A4

B4

C4

D4

E4

A5

B5

C5

D5

E5

A6

B6

C6

D6

E6

DETAIL NUMBER

DETAIL SCALE

DETAIL NAME

DETAIL

NUMBER

PLAN SETUP

SHEET

NUMBER

WHERE DETAIL

IS LOCATED

CAUTION: THESE DOCUMENTS WERE DIGITALLY PRODUCED AND/OR REPRODUCED.

CONFIRM REDUCTION OR MAGNIFICATION USING DIMENSIONAL 3"-LONG LINE IN TITLE

BARS. IF SCALING DRAWINGS FOR APPROXIMATE DIMENSIONS, ALTERNATE

ARCHITECTURAL SCALES MAY BE USED AS FOLLOWS:

DOCUMENT REDUCTION/MAGNIFICATION SCALE

IF LINE MEASURES 2” (67% COPY):

USE 3/16th SCALE ON 1/8”=1’-0” DWG USE 3/8th SCALE ON 1/4”=1’-0” DWG

IF LINE MEASURES 1.5” (50% COPY):

USE 1/16th SCALE ON 1/8”=1’-0” DWG USE 1/8th SCALE ON 1/4”=1’-0” DWG

3"

3"

? XXX

X" = X"

NOTES:

F

FINISHED FLOOR

D U

P L E

X R

E C

E P

T A

C L E

F

S E

E N

O T

E

F

IR

E A

L A

R M

P U

L L S

T A

T

IO

N

F

F

IR

E A

L A

R M

A /V

D E

V

IC

E

F

IR

E A

L A

R M

V

IS

U A

L D

E V

IC

E

S E

E N

O T

E

1. IN LOCATIONS WHERE SIMILAR DEVICES ARE MOUNTED AT THE SAME HEIGHT

DEVICES SHALL BE PROPERLY "GANGED" AND SHALL HAVE A SINGLE COVER PLATE.

2. IN LOCATIONS WHERE DIFFERENT DEVICES ARE MOUNTED AT DIFFERENT HEIGHTS

WITHIN FOUR FEET OF ONE ANOTHER. DEVICES SHALL BE MOUNTED SUCH THAT

THEY HAVE A COMMON CENTER LINE. IF THERE ARE THREE OR MORE DEVICES THE

CONTRACTOR SHALL REQUEST A DETAIL FROM THE ARCHITECT.

3. 42" MINIMUM TO 48" MAXIMUM AND WITHIN 5FT FROM DOOR.

4. 80" OR, AT SHALLOW CEILING INSTALLATIONS, WITHIN 6" OF FINISHED CEILING.

VERIFY WITH ENGINEER.

FLOOR ABOVE

FLOOR DECKING

BEAM

HVAC

DUCT

FINISHED

CEILING

LIGHT FIXTURE

PROVIDE LOCKNUTS AND

WASHERS AS REQUIRED.

3/8" THREADED ROD

TYPICAL FOR TWO (2).

1 5/8" X 1 5/8" STRUCTURAL

CHANNEL PROVIDE LOCKNUTS

AND WASHERS AS REQUIRED.

2" X 2" X 5/16", CLAMP

TO BEAM, CLIP

ANGLE AS REQUIRED.

INSTALL PRIOR TO

FIRE PROOFING.

/2

ABOVE COUNTER - 6" ABOVE COUNTERTOP OR BACKSPLASH

ABBREVIATIONS

SYMBOL DESCRIPTION

AC

ABOVE FINISHED FLOORAFF

AUTOMATIC FLUSH/FAUCET TRANSFORMER, REFER TO DETAILAFT

ABOVE GRADEAG

AT UNITAU

CONDUITC

CARD ACCESS PANELCAP

CARD ACCESS CONTROL PANELCACP

CIRCUITCKT

CAMERA POWER SUPPLYCPS

CONNECT TO EMERGENCY CIRCUITEM

ELECTRIC METALLIC TUBINGEMT

ELECTRIC WATER COOLEREWC

FIRE SMOKE DAMPER. PROVIDE CONNECTIONS AS INDICATEDFS

GROUNDG

GROUND FAULT INTERRUPT DEVICEGF

NON-FUSEDNF

NIGHT LIGHTNL

VARIABLE FREQUENCY CONTROLLERVFC

WEATHERPROOFWP

WIRE GUARDWG

EXISTING TO REMAINEX

REMOVE AND REINSTALLR/R

SURGE PROTECTEDSP

LIGHTING CONTROL STATION, SUBSCRIPT INDICATES TYPE

DO = DIMMER SWITCH WITH INTEGRAL OCCUPANCY SENSOR

DS = DIGITAL SCENE SWITCH - 5 BUTTON CONTROL

DEVICE SYMBOLS

SYMBOL DESCRIPTION

DAY LIGHT SENSORDS

a

WALL SWITCH

3 = THREEWAY, a = FOR LIGHTING FIXTURE MARKED SAME k = KEYED SWITCH; P = PILOT LIGHT

WALL SWITCHES GANGED ON ONE PLATE

MAY BE LOCATED WITH DOT

OS

CEILING MOUNTED OCCUPANCY SENSOR, SUBSCRIPT INDICATES TYPE

2 = ULTRASONIC

3 = DUAL TECHNOLOGY INFRARED/ULTRASONIC

C = CORRIDOR

V = VACANCY

OS WALL MOUNTED OCCUPANCY SENSOR

TYPE 1 UNLESS OTHERWISE INDICATED, REFER TO SPECIFICATIONS

PC PHOTOCELL

AC DUPLEX RECEPTACLE OUTLET, WALL MOUNTED FLUSH / ABOVE

COUNTER MOUNTED

DUPLEX RECEPTACLE OUTLET WITH TWO (2) INTEGRAL USB CHARGING

JACKS, WALL MOUNTED

GF/AC G.F.C.I. DUPLEX RECEPTACLE OUTLET, WALL MOUNTED / ABOVE

COUNTER MOUNTED

GF

WP WEATHERPROOF DUPLEX RECEPTACLE OUTLET

FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE OUTLET

IG

ISOLATED GROUND DUPLEX RECEPTACLE OUTLET

SPECIAL PURPOSE RECEPTACLE OUTLET

NEMA CONFIGURATION TO MATCH PLUG

J JUNCTION BOX

J CORD REEL - SURFACE MOUNTED - EXPOSED - NO CEILING

J CORD REEL - SURFACE MOUNTED - ABOVE ACT CEILING

CR

CR-R

BRANCH CIRCUITRY: 2 #12, 1 #12G, 1/2"C UNLESS OTHERWISE NOTED.

BRANCH CIRCUITRY = WIRING/ CONDUCTORS, RACEWAYS AND

ASSOCIATED SUPPORTS, FITTINGS AND HARDWARE.

BRANCH CIRCUIT HOMERUN: 2 #12, 1 #12G, 1/2"C TO PANELBOARD

CIRCUIT NUMBER AS INDICATED UNLESS OTHERWISE NOTED.

B1 / 12 = PANEL NAME / CIRCUIT NUMBER.

BRANCH CIRCUITRY = WIRING/ CONDUCTORS, RACEWAYS AND

ASSOCIATED SUPPORTS, FITTINGS AND HARDWARE.

B1/12

TWO SECTION SURFACE RACEWAY

TYPE, REFER TO SPECIFICATION

BOILER SHUTDOWN

R EMERGENCY/ NON-EMERGENCY LIGHTING CONTROL RELAY

DS

AC DOUBLE DUPLEX RECEPTACLE OUTLET, WALL MOUNTED / ABOVE

COUNTER MOUNTED

4 PORT (QUAD) USB CHARGER OUTLET

WALL BOX DIMMER SWITCH, 0 - 10V

U

EMERGENCY POWER OFF

FLUSH CEILING MOUNTED DUPLEX RECEPTACLE OUTLET

EPO

FIRE ALARM SYSTEM CONTROL PANEL

FIRE ALARM SYMBOLS

SYMBOL DESCRIPTION

FIRE ALARM SYSTEM ANNUNCIATOR

CARBON MONOXIDE DETECTOR, HARDWIRED TO FIRE ALARM SYSTEM

FIRE ALARM CONNECTION. SUBSCRIPT IDENTIFIES TYPE:

SD - SMOKE DAMPER

FA - FIRE ALARM SHUTDOWN OF EQUIPMENT

FS - SPRINKLER FLOW SWITCH

TS - SPRINKLER TAMPER SWITCH

PIV - SPRINKLER POST INDICATOR VALVE

FIRE ALARM SYSTEM VISUAL (ONLY) INDICATING APPLIANCE, WALL

MOUNTED. SUBSCRIPTS: 15 = CANDELA INTENSITY

FAA

FACP

F FIRE ALARM SYSTEM MANUAL PULL STATION

FIRE ALARM SYSTEM SMOKE DETECTOR

DSD

FIRE ALARM SYSTEM SMOKE DETECTOR, DUCT MOUNTED

FIRE ALARM SYSTEM THERMAL DETECTOR

CO

NATURAL GAS DETECTOR, HARDWIRED TO FIRE ALARM SYSTEM

GAS

FIRE ALARM SYSTEM MAGNETIC DOOR HOLD OPEN

SD

FA

F 2W

FIRE ALARM SYSTEM COMBINATION VISUAL AND AUDIBLE INDICATING

DEVICE, WALL MOUNTED. SUBSCRIPTS: WP = WEATHERPROOF, WG =

WIRE GUARD, 75 = CANDELA INTENSITY, 2W = WATTAGE TAP

F

FIRE ALARM SYSTEM - BEAM TYPE SMOKE DETECTOR - TRANSMITTER

FIRE ALARM SYSTEM - BEAM TYPE SMOKE DETECTOR - RECEIVER

FIRE ALARM SYSTEM - REMOTE TEST SWITCHRTS

F

F

NAC…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .