This document contains details of a federal contract opportunity for nurse call services. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6 is soliciting bids for contract number 36C24621B0004 to provide nurse call services. Bidders must submit a completed SF-1442 form, representations and certifications, bid bond or guaranty, documentation of their safety record, and any other required forms or certifications by the specified due date. The opportunity is set aside for verified veteran-owned or service-disabled veteran-owned small businesses. The solicitation includes specifications for the required nurse call services.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 20-091 CD ReplNrsCallSpecs 20210210.pdf | ||
| 36C24621B0004_1.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
P
M
G-001
COVER SHEET
PROJECT SITE MAPPROJECT LOCATION MAP
PROJECT
LOCATION
PROJECT SITE
NORTH
NORTH
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
321 4 5 6 7
A B
C E
Dwg. of
LocationLocation
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
Revisions: Date
CONSULTANTS:
FEBRUARY 10, 2021 RER
REPLACE NURSE CALL
SYSTEM
659-20-201
20-091
CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
© COPYRIGHT Apogee Consulting Group, P.A.
2, 5, 8, 21
5KK
Engineers Architects
U.S. Department of Veterans Affairs
SALISBURY VA MEDICAL CENTER
1601 BRENNER AVENUE
SALISBURY, NC 28144
NC License #: C-1848
REPLACE NURSE CALL SYSTEM
SALISBURY VA MEDICAL CENTER
1601 BRENNER AVENUE
SALISBURY, NC 28144
VA PROJECT #: 659-20-201 APOGEE PROJECT #: 20-091
DRAWING LIST
11811
KO
RLA K . KUDJ IKU
C
HARLOTTE , NORTH CAROL
I N
ANOR T H C A R O L I N
A
RE
G I
STERED ARCH ITECT
DocuSign Envelope ID: 60368EC4-1477-4FAA-ABB4-1158A2CA06AA
2/9/2021
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
321 4 5 6 7
A B
C E
Dwg. of
LocationLocation
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
Revisions: Date
CONSULTANTS:
FEBRUARY 10, 2021 RER
REPLACE NURSE CALL
SYSTEM
659-20-201
20-091
CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
© COPYRIGHT Apogee Consulting Group, P.A.
2, 5, 8, 21
5KK
Engineers Architects
U.S. Department of Veterans Affairs
SALISBURY VA MEDICAL CENTER
1601 BRENNER AVENUE
SALISBURY, NC 28144
NC License #: C-1848
SITE KEY PLAN
G-002
LEGEND
EXISTING BUILDING
EXISTING BUILDING - PART OF SCOPE
SITE KEY PLAN
Scale: 1"=100'
BUILDING ENTRANCE
BID ALTERNATES
REFERENCE SECTION 01 00 00 OF THE SPECIFICATIONS FOR THE SCHEDULE OF BID ALTERNATES TO
BE INCLUDED WITH THE BID PACKAGE.
BID DEDUCT ALTERNATE # 1:
1. REMOVE ALL WORK ASSOCIATED WITH BUILDING 21 SECOND FLOOR.
BIDDER SHALL PROVIDE A SEPARATE BID PRICE FOR THIS WORK. IF THE BID DEDUCT ALTERNATE IS
NOT ACCEPTED, THE AREA WILL BE RENOVATED PER DRAWINGS AND SPECIFICATIONS.
N
O
R
T
H
50' 100' 200'0
11811
KO
RLA K . KUDJ IKU
C
HARLOTTE , NORTH CAROL
I N
ANOR T H C A R O L I N
A
RE
G I
STERED ARCH ITECT
INTERIM LIFE SAFETY MEASURES IN EFFECT FOR THE
REPLACE NURSE CALL SYSTEM
THIS EXIT IS CLOSED AND LEADS TO A
CONSTRUCTION AREA
PLEASE USE ALTERNATE EXITS AS MARKED
1'-5"
INFECTION CONTROL RISK
ASSESSMENT, INTERIM LIFE
SAFETY MEASURES, FIRE WATCH
AND MISCELLANEOUS FORMS
PAPER
CADDY
ILSM TEMPORARY BARRIER TAG
PROJECT:
PRIME CONTRACTOR:
SUB CONTRACTOR:
EMERGENCY CONTACT NO.:
BARRIER INSTALLATION DATE:
BARRIER EXPIRATION DATE:
FIRE EXTINGUISHER ON
PORTABLE FLOOR
BRACKET (ILSM MAY
REQUIRE MORE THAN
ONE).
PROVIDE STICKY
MATS (CHANGED END
OF SHIFT OR MORE IF
NECESSARY TO
MAINTAIN
CLEANLINESS).
HEPA NEGATIVE
AIR UNIT
SUPPLY DUCTS
EITHER KEEP
RUNNING OR COVER
WHEN RUNNING TO
KEEP DUST OUT
COVER ALL RETURNS
AT THE
GRATE/DIFFUSERS
F L
E X
D
U C
T
SUSPENDED PLASTIC
ZIPPER WALL
CURTAIN BARRIER
POST ICRA, ILSM, FIRE
INPECTION SHEETS
VISIBLE TO PUBLIC
FIRE PULL
STATION WITH
AUDIO / VISUAL
G-100
G-100
G-100
DUCT TO OUTSIDE
OF BUILDING
HEPA
NEGATIVE AIR
UNIT
FINISHED FLOORING TO BE KEPT CLEAN. FLOORS NOT BEING
REPLACED MUST BE PROTECTED. COVER WITH ROSIN PAPER /
FIRE RATED PLYWOOD.
FIRE RATED PLYWOOD,
TEMPORARY. SALVAGE
PROTECT AND STORE
EXISTING WINDOW TO
BE RE-INSTALLED
AFTER CONSTRUCTION
IS COMPLETE.
V I F
V.I.F.
E X
I S
T I N
G
W
A L
L
V I F
E X
I S
T I N
G
W
A L
L
V I F
V I F
A P
P R
O X
A
F
F
SUSPENDED
PLASTIC ZIPPER
WALL CURTAIN
BARRIER
POST ICRA,
ILSM, FIRE
INSPECTION
SHEETS VISIBLE
TO PUBLIC
G-100
INFECTION CONTROL RISK MITIGATION RECOMMENDATIONS MATRIX
OF PRECAUTIONS FOR CONSTRUCTION AND RENOVATION
Class III
Patient Risk Group Table
Infection Control Matrix - Class of Precautions: Construction
Project by Patient Risk
TYPE A
Construction Project Type
Major demolition and construction projects
Includes, but is not limited to:
- activities which require consecutive work shifts
- requires heavy demolition or removal of a complete ceiling system
- new construction
Work that generates a moderate to high level of dust or requires demolition or removal of any fixed building components or assemblies
Includes, but is not limited to:
- sanding of walls for painting or wall covering
- removal of floor coverings, ceiling tiles and casework
- new wall construction
- minor duct work or electrical work above ceilings
- major cabling activities
- any activity which cannot be completed within a single work shift
Small scale, short duration activities which create minimal dust
Includes, but is not limited to:
- installation of telephone and computer cabling
- access to chase spaces
- cutting of walls or ceiling where dust migration can be controlled
Inspection and Non-Invasive Activities
Includes, but is not limited to:
- removal of ceiling tiles for visual inspection limited to 1 tile to 50 square feet
- painting (but not sanding), wall covering
- electrical trim work, minor plumbing, and activities which do not generate dust or require cutting of walls or access to ceilings other than for visual inspection
Type of Construction / Project Activity Table
Group 2
Medium Risk
- Therapy Areas
- Respiratory Therapy
- Outpatient Clinics
- CBOC's
- Mental Health Units
- VACANT AREA ADJACENT TO
OCCUPIED AREA
I
Patient Risk Group
TYPE
D
Group 3
High Risk
- Pharmacy
- Radiology/ CT Scanner
- Urgent Care
- Laboratories
- CLCs
- SPD
- AMCU
- Respiratory Isolation Rooms
I
TYPE DTYPE CTYPE B
o r control procedures are necessary.
During Construction Project
C L A
S S
I I I
1. Remove barrier materials carefully to minimize spreading of dirt and debris associated with construction.
2. Contain construction waste before transport in tightly covered containers.
3. Cover transport receptacles or carts. Tape covering.
4. Vacuum work area with HEPA filtered vacuums.
5. Wet mop area with disinfectant after barriers are removed.
6. Remove or isolate HVAC system in areas where work was being performed.
1. Remove barrier materials carefully to minimize spreading of dirt and debris associated with construction.
2. Contain construction waste before transport in tightly covered containers.
3. Cover transport receptacles or carts. Tape covering.
4. Vacuum work with HEPA-filtered vacuums.
5. Wet mop with disinfectant.
6. Remove isolation of HVAC system in areas where work is being performed.
1. Wipe surfaces to remove dust
Upon Completion of Project
1. Wipe work surfaces with disinfectant.
2. Contain construction waste before transport in tightly covered containers.
3. Wet mop and/or vacuum work area with HEPA filtered vacuum before leaving work areas.
4. Remove isolation of HVAC system in areas where work is being performed.
1. Includes all activities required by Class II
2. Obtain Infection Control Permit from Hospital Safety Officer or Facilities
Management Maintenance and Engineering department before construction begins.
3. Remove or isolate HVAC system in area where work is being done to prevent contamination of duct system.
4. Complete all critical barriers before construction begins or implement control cube method.
5. Maintain negative air pressure within work site utilizing HEPA-equipped air filtration units.
6. Contain construction waste before transport in tightly covered containers.
7. Cover transport receptacles or carts. Tape covers.
8. Wet mop and/or vacuum with HEPA filtered vacuum before leaving work areas.
9. Remove isolation of HVAC system in areas where work is being performed.
1. Execute work by methods to minimize raising dust from construction operations.
1. Includes all activities required by Class I
2. Provide active means to prevent airborne dust from dispersing into atmosphere.
3. Water mist work surfaces to control dust while cutting.
4. Seal unused doors with duct tape.
5. Block off and seal air vents.
6. Replace adhesive walk-off mats at entrance and exit of work area.
Replace used mats in accordance with manufacturer's recommendations.
7. Remove or isolate HVAC system in area where work is being done to prevent contamination of duct system.
1. Includes all activities required by Class III.
2. Obtain Infection Control Permit from Hospital Safety Officer or Facilities
Management Maintenance and Engineering department before construction begins.
3. Isolate HVAC system in areas where work is being done to prevent contamination of duct system.
4. Complete all critical barriers or implement control cube method before construction begins.
5. Maintain negative air pressure within work site utilizing HEPA equipped air filtration units.
6. Seal holes, pipes, conduits, and punctures appropriately.
7. Construct anteroom and require all personnel to pass through this room so they can be vacuumed using a HEPA vacuum cleaner before leaving work site or they can wear cloth or paper coveralls that are removed each time they leave the work site.
8. All personnel entering work site are required to wear shoe covers.
Shoe covers must be changed each time the worker exits the work area.
9. Place adhesive walk-off mats at entrance to work area within anteroom.
10. Replace walk-off mats per manufacturer's recommendations. Do not remove work area barriers until completed project is inspected each by the Hospital Department Safety Officer, Facilities Management Maintenance and Engineering and thoroughly cleaned by the Hospital Environmental Services Department or their contracted Environmental Service Company. Contain construction waste before transport in tightly covered containers.
11. Cover transport receptacles or carts. Tape covering.
12. Vacuum work area with HEPA filtered vacuums.
13. Wet mop with disinfectant after barriers are removed.
14. Remove isolation of HVAC system in areas where work is being performed.
Class IV
Note: Infection Control approval will be required when the Construction Activity and Risk Level indicate that
It is the Contractor's Responsibility to provide the following Infection Control
Precautions depending upon the Area Class Designation
II
I
LOW Risk Group 1
HIGH Risk Group 3
HIGHEST Risk Group 4
MEDIUM Risk Group 2
IV
IV
IV
III/IV
III/IV
III/IV
III/IV
III
III
III
- Office areas (non-clinical)
- Hallways
- FES/EMS areas
TYPE
B
I
TYPE
C
Group 4
Highest Risk
C L A
S S
I V
TYPE
A
Group 1
Low Risk
II
C L A
S S
I
C L A
S S
I I
A
M
G-100
TYPICAL ICRA DETAILS
Scale: No Scale
ILSM SIGNAGE
Scale: No Scale
ILSM BARRIER TAG
Scale: 1/2" = 1'-0"
TYPICAL CONSTRUCTION PLAN LAYOUT
Scale: 1/2" = 1'-0"
CROSS SECTION A
Scale: 1/2" = 1'-0"
ROOM ELEVATION
A.
B.
C.
D.
NOTE:
TAG SHALL BE PLACED ON ALL ILSM
TEMPORARY BARRIERS. FINAL LOCATION BY G.C.
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
SHEET NOTES:
321 4 5 6 7
A B
C E
Dwg. of
LocationLocation
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
Revisions: Date
CONSULTANTS:
FEBRUARY 10, 2021 RER
REPLACE NURSE CALL
SYSTEM
659-20-201
20-091
CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
© COPYRIGHT Apogee Consulting Group, P.A.
2, 5, 8, 21
5KK
Engineers Architects
U.S. Department of Veterans Affairs
SALISBURY VA MEDICAL CENTER
1601 BRENNER AVENUE
SALISBURY, NC 28144
NC License #: C-1848
TAPE ALL SERVICES TO PROTECT AGAINST
CONTAMINATION.
THE CONTRACTOR SHALL NOT HAUL DEBRIS
THROUGH PATIENT-CARE AREAS WITHOUT PRIOR
APPROVAL OF THE COR AND THE MEDICAL CENTER.
USING A HEPA VACUUM, CLEAN INSIDE THE BARRIER
AND VACUUM CEILING TILE PRIOR TO REPLACEMENT.
ANY CEILING ACCESS PANELS OPENED FOR
INVESTIGATION BEYOND SEALED AREAS SHALL BE
SEALED IMMEDIATELY WHEN UNATTENDED.
AT COMPLETION, REMOVE CONSTRUCTION
BARRIERS AND CEILING PROTECTION CAREFULLY,
OUTSIDE OF NORMAL WORK HOURS. VACUUM AND
CLEAN ALL SURFACES FREE OF DUST AFTER THE
REMOVAL.
CONTRACTOR TO VERIFY AND COORDINATE FINAL
AND APPROVED ICRA MEASURES WITH THE
SALISBURY VA MEDICAL CENTER'S ICRA PERSONNEL,
PRIOR TO THE COMMENCEMENT OF CONSTRUCTION
ACTIVITY.
E.
11811
KO
RLA K . KUDJ IKU
C
HARLOTTE , NORTH CAROL
I N
ANOR T H C A R O L I N
A
RE
G I
STERED ARCH ITECT
EXAM
EXAM
PH 2 RM 3
STORAGE
ELECT
4129A
TOILET
M I N
C L
E A
R
3073A
PATIENT
TLT
3072A
PATIENT
TLT
3071A
CHARTING
STATION
3071B
CHARTING
STATION
3066A
PATIENT
TLT
PATIENT
ROOM
PATIENT
ROOM
ROOM
ANT. ISO
3072B
C
L
E
A
R M
I
N
TLT
CL.UTIL
1-BED
1-BED
3160A
ELEC
TLT
TELEPHONE
3163A
FAC
TLT
TLT
5 6
4 5
M I N
C L
E A
R
MECH RM
CLEAN SUP
3039A
PAT. TLT
PAT. ROOM
3054A
PAT. TLT
PAT. ROOM
3040A
PAT. TLT
3045B
CORRIDOR
ALCOVE
3042A
PAT. TLT
5 6
5 6
M
I
N
C
L
E
A
R
BREAK
TLT
WAITING
M.TLT
CLEAN SUP
CLEAN SUP
EQUIP STOR
HAC
ELEC
F. TLT
M. TLT
EQUIP
STOR
STAIR #6
LINEN CHUTE
4 5 6
C L
E A
R
M I N
Soiled
1C134
Telecom
1C135
Elec
1C136
Kitchen
1C100
Patio
1E119
Corridor
C1-26
1C118
Laundry
1C119
Bath
1C117A
Staff Tlt
Resident Kitchen
1C101
Dining Room
LOCKERS
TLT
ELECT
FEC
3045A
CORRIDOR
NURSE STATION
STAIR #6
4 5 6
6'-0"
MIN.
CLEAR
C L E
A R
M I N
C L E
A R
M I N
CORRIDOR
STORAGE
ICU
4 5 6
M
I
N
C
L
E
A
R
2 2
PRE OP
4017A
STORAGE
4017B
TLT
EXAM
CORRIDOR
ELEC
4 5 6
M I N
C L
E A
R
PH 1 PACU
4100A
EQUIP STORAGE
FAC
PH 1 PACU
SOILED
TOILET
CORR
4 5
M I N
C L
E A
R
1 TYPICAL EXAM ROOM (CLASS IV)
SCALE: 1/8" = 1' 0"
G-101
5 TYPICAL LAUNDRY ROOM (CLASS II)
SCALE: 1/8" = 1' 0"
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
SHEET NOTES:
SHEET KEY NOTES:
321 4 5 6 7
A B
C E
Dwg. of
LocationLocation
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
Revisions: Date
CONSULTANTS:
FEBRUARY 10, 2021 RER
REPLACE NURSE CALL
SYSTEM
659-20-201
20-091
CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
© COPYRIGHT Apogee Consulting Group, P.A.
2, 5, 8, 21
X
5KK
Engineers Architects
U.S. Department of Veterans Affairs
SALISBURY VA MEDICAL CENTER
1601 BRENNER AVENUE
SALISBURY, NC 28144
NC License #: C-1848
SS
2 HOUR FIRE SEPARATION
1 HOUR FIRE SEPARATION
SMOKE RATED
WALL RATING LEGEND
1. PROVIDE TEMPORARY PLASTIC BARRIER
PARTITION TO THE UNDERSIDE OF CEILING WITH
ZIPPER ENTRY. PARTITION SHALL BE INSPECTED
BY VA ICRA STAFF PRIOR TO START OF
CONSTRUCTION IN SPACE. MAINTAIN NEGATIVE
PRESSURE VENTILATION IN THE CONSTRUCTION
SPACE.
2. PROVIDE TWO STICKY MATS AT EACH
CONSTRUCTION ACCESS POINT IN ALL PHASES.
3. WORK TO BE PERFORMED AT THE MASTER AND
SLAVE CONTROL PANEL LOCATIONS SHALL BE
PERFORMED AT ONE LOCATION AT A TIME.
4. USE A PORTABLE DUST EXTRACTOR AND AIR
SCRUBBER WITH HEPA FILTRATION SYSTEM.
5. CONTRACTOR SHALL COVER ALL FURNITURE
WITHIN ROOM WITH PLASTIC, PRIOR TO
COMMENCING WORK IN A SPACE AND REMOVE
PRIOR TO POST-CONSTRUCTION TERMINAL
CLEANING.
6. THE AIR WITHIN THE CONSTRUCTION AREA SHALL
BE NEGATIVE WITH RESPECT TO SURROUNDING
AREAS AND WITH NO DISRUPTION OF AIR
SYSTEMS OF ADJACENT AREAS. USE OF THE
NEGATIVE AIR PRESSURE SYSTEM WITHIN THE
ENCLOSURE TO REMOVE DUST SHALL PASS AIR
THROUGH AN INDUSTRIAL GRADE, PORTABLE
HEPA FILTER CAPABLE OF FILTRATION RATES OF
300-800 CUBIC FEET PER MINUTE (FT3/MIN), OR
EXHAUST AIR DIRECTLY TO THE OUTSIDE IF
APPROVED BY VAMC. IF EXHAUST INTO A ROOM,
A PRE-FILTER AND HEPA FILTER SHALL BE USED
BEFORE EXHAUST.
A. REMOVE ALL TRASH DAILY FROM THE WORK AREA.
B. THESE DRAWINGS ARE BASED ON FIELD SURVEY
AND EXISTING PLANS. VERIFY ALL FIELD
CONDITIONS.
C. COORDINATE WITH VA COR FOR OFF-HOURS
SCHEDULE AND TEMPORARY REROUTING ACCESS
FOR HOSPITAL STAFF AND VISITORS, PRIOR TO
ERECTING TEMPORARY BARRIERS.
D. CONSULT WITH VA SAFETY DEPARTMENT TO
MAINTAIN MINIMUM CLEARANCE IN CORRIDORS AND
HALLWAYS.
E. EXISTING WINDOWS THAT NEED TO BE
TEMPORARILY REMOVED TO ACCOMMODATE
DISCHARGED AIR EXHAUST DUCT, SHALL BE
RE-INSTALLED AFTER CONSTRUCTION.
F. CONTRACTOR TO VERIFY AND COORDINATE FINAL
AND APPROVED ICRA MEASURES WITH THE
SALISBURY VA MEDICAL CENTER'S ICRA
PERSONNEL, PRIOR TO THE COMMENCEMENT OF
CONSTRUCTION ACTIVITY.
2 TYPICAL PATIENT ROOM (CLASS IV)
SCALE: 1/8" = 1' 0"
3 TYPICAL 1-BED PATIENT ROOM (CLASS IV)
SCALE: 1/8" = 1' 0"
4 TYPICAL PATIENT ROOM (CLASS IV)
SCALE: 1/8" = 1' 0"
10 TYPICAL ELECT ROOM (CLASS II)
SCALE: 1/8" = 1' 0" 6 MALE TOILET (CLASS IV)
SCALE: 1/8" = 1' 0"
7 TYPICAL OFFICE (CLASS II)
SCALE: 1/8" = 1' 0"
8 PATIENT TLT (CLASS II)
SCALE: 1/8" = 1' 0"
9 AND ELEC ROOM (CLASS II)
SCALE: 1/8" = 1' 0"
11 TYPICAL NURSE STATION (CLASS IV)
SCALE: 1/8" = 1' 0"
12 TYPICAL ICU (CLASS IV)
SCALE: 1/8" = 1' 0"
13 TYPICAL PRE-OP ROOM (CLASS IV)
SCALE: 1/8" = 1' 0"
14 TYPICAL PH 1 PACU ROOM (CLASS IV)
SCALE: 1/8" = 1' 0"
14 TYPICAL MEN'S AND WOMEN'S TOILETS (CLASS II)
SCALE: 1/8" = 1' 0"
15 TYPICAL TELECOMM ROOM (CLASS II)
SCALE: 1/8" = 1' 0"
ENLARGED ICRA PLANS
TYPICAL TELECOM AND
TYPICAL FEMALE AND
TYPICAL OFFICE/
11811
KO
RLA K . KUDJ IKU
C
HARLOTTE , NORTH CAROL
I N
ANOR T H C A R O L I N
A
RE
G I
STERED ARCH ITECT
2C105
SOILED UTILITY
2C15
CORR
2C106A
TOILET
2C114
TELECOMM
2C112A
TOILET
2C106
GENERAL
INFUSION
C213A
CRASH CART
ALCOVE
2C108
CHEMO
INFUSION
C213
CORR
2C108A
TOILET
2C107
GENERAL
INFUSION
2C108B
CHEMO
INFUSION
2C109A
CHEMO
INFUSION
2C109
CHEMO
INFUSION
5 6
5 64
5 64
5 64
DINING
AC302A
SCREENED
PORCH 1
A309
PATIENT ROOM
LAUNDRY
A307
5 64
C L
E A
R
M I N
EXERCISE
ROOM
A323
DINING
AC303A
PATIENT
CORRIDOR
AC303
5 64
6'-0"
CLEAR
MIN.
DOUBLE
PATIENT ROOM
A329
TV AREA
A328
SINGLE
PATIENT ROOM
A327
BATHROOM 10
A329A
BATHROOM 11
A326A
DOUBLE
PATIENT ROOM
A326
SINGLE
PATIENT ROOM
A324
DAY
AC303B
5 64
2A119
ENDO
PROCEDURE
SALLY PORT
2A100
ENDO
2A120
SALLY PORT
2A121
ENDO
PROCEDURE
5 6
G-102
ENLARGED ICRA PLANS
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
SHEET NOTES:
SHEET KEY NOTES:
321 4 5 6 7
A B
C E
Dwg. of
LocationLocation
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
Revisions: Date
CONSULTANTS:
FEBRUARY 10, 2021 RER
REPLACE NURSE CALL
SYSTEM
659-20-201
20-091
CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
© COPYRIGHT Apogee Consulting Group, P.A.
2, 5, 8, 21
X
5KK
Engineers Architects
U.S. Department of Veterans Affairs
SALISBURY VA MEDICAL CENTER
1601 BRENNER AVENUE
SALISBURY, NC 28144
NC License #: C-1848
SS
2 HOUR FIRE SEPARATION
1 HOUR FIRE SEPARATION
SMOKE RATED
WALL RATING LEGEND
5 CHEMO INFUSION BAYS (CLASS IV)
SCALE: 1/8" = 1' 0"
1 TYPICAL SCREENED PORCH (CLASS IV)
SCALE: 1/8" = 1' 0"
2 TYPICAL EXERCISE ROOM (CLASS IV)
SCALE: 1/8" = 1' 0"
3 TYPICAL TV AREA (CLASS IV)
SCALE: 1/8" = 1' 0"
4 TYPICAL ENDO PROCEDURE (CLASS IV)
SCALE: 1/8" = 1' 0"
TYPICAL GENERAL AND
1. PROVIDE TEMPORARY PLASTIC BARRIER
PARTITION TO THE UNDERSIDE OF CEILING WITH
ZIPPER ENTRY. PARTITION SHALL BE INSPECTED
BY VA ICRA STAFF PRIOR TO START OF
CONSTRUCTION IN SPACE. MAINTAIN NEGATIVE
PRESSURE VENTILATION IN THE CONSTRUCTION
SPACE.
2. PROVIDE TWO STICKY MATS AT EACH
CONSTRUCTION ACCESS POINT IN ALL PHASES.
3. WORK TO BE PERFORMED AT THE MASTER AND
SLAVE CONTROL PANEL LOCATIONS SHALL BE
PERFORMED AT ONE LOCATION AT A TIME.
4. USE A PORTABLE DUST EXTRACTOR AND AIR
SCRUBBER WITH HEPA FILTRATION SYSTEM.
5. CONTRACTOR SHALL COVER ALL FURNITURE
WITHIN ROOM WITH PLASTIC, PRIOR TO
COMMENCING WORK IN A SPACE AND REMOVE
PRIOR TO POST-CONSTRUCTION TERMINAL
CLEANING.
6. THE AIR WITHIN THE CONSTRUCTION AREA SHALL
BE NEGATIVE WITH RESPECT TO SURROUNDING
AREAS AND WITH NO DISRUPTION OF AIR
SYSTEMS OF ADJACENT AREAS. USE OF THE
NEGATIVE AIR PRESSURE SYSTEM WITHIN THE
ENCLOSURE TO REMOVE DUST SHALL PASS AIR
THROUGH AN INDUSTRIAL GRADE, PORTABLE
HEPA FILTER CAPABLE OF FILTRATION RATES OF
300-800 CUBIC FEET PER MINUTE (FT3/MIN), OR
EXHAUST AIR DIRECTLY TO THE OUTSIDE IF
APPROVED BY VAMC. IF EXHAUST INTO A ROOM,
A PRE-FILTER AND HEPA FILTER SHALL BE USED
BEFORE EXHAUST.
A. REMOVE ALL TRASH DAILY FROM THE WORK AREA.
B. THESE DRAWINGS ARE BASED ON FIELD SURVEY
AND EXISTING PLANS. VERIFY ALL FIELD
CONDITIONS.
C. COORDINATE WITH VA COR FOR OFF-HOURS
SCHEDULE AND TEMPORARY REROUTING ACCESS
FOR HOSPITAL STAFF AND VISITORS, PRIOR TO
ERECTING TEMPORARY BARRIERS.
D. CONSULT WITH VA SAFETY DEPARTMENT TO
MAINTAIN MINIMUM CLEARANCE IN CORRIDORS AND
HALLWAYS.
E. EXISTING WINDOWS THAT NEED TO BE
TEMPORARILY REMOVED TO ACCOMMODATE
DISCHARGED AIR EXHAUST DUCT, SHALL BE
RE-INSTALLED AFTER CONSTRUCTION.
F. CONTRACTOR TO VERIFY AND COORDINATE FINAL
AND APPROVED ICRA MEASURES WITH THE
SALISBURY VA MEDICAL CENTER'S ICRA
PERSONNEL, PRIOR TO THE COMMENCEMENT OF
CONSTRUCTION ACTIVITY.
11811
KO
RLA K . KUDJ IKU
C
HARLOTTE , NORTH CAROL
I N
ANOR T H C A R O L I N
A
RE
G I
STERED ARCH ITECT
TECHNOLOGY SYMBOL LEGEND
DATA OUTLET - 2-4 PR UTP
SYMBOL HEIGHT DESCRIPTION
18"
18"
48"
ALL HEIGHTS ARE TO CENTER OF DEVICE UNLESS NOTED OTHERWISE.
ANY HEIGHTS INDICATED IN PLANS SHALL SUPERCEDE THOSE LISTED HERE.
SEE DRAWINGS FOR MORE INFORMATION.
NOTE: NOT ALL SYMBOLS ARE USED.
ENHANCED NURSE CALL PATIENT STATION WITH ENHANCED PILLOW SPEAKER AND
CLEAR BUTTON COVER (X - NO CLEAR BUTTON COVER)
NURSE CALL EMERGENCY STATION WITH PULL CORD WITH AUDIO IN
RESTROOM (+40"), NO AUDIO IN SHOWER (V - VANDAL RESISTANCE, PB - PUSH BUTTON,
HS - HIGH SECURITY STEEL COVER PLATE)
NURSE CALL DOME LIGHT - CEILING MOUNTED
(Z - ZONE LIGHT, V - VANDAL RESISTANCE)
18"
44"
84"/96"
HEADWALL
/40"
18"
HEADWALL
/40"
40",72"
60"
CEILING
CEILING
6' TO
TOP
NURSE CALL PATIENT STATION WITH CALL CORD AND CLEAR PLASTIC COVER.
(1 - SINGLE, 2 - DUAL, V - VANDAL RESISTANCE, HS - HIGH SECURITY STEEL
COVER PLATE, X - NO PLASTIC COVER)
42"
CEILING
ABOVE
DOOR
FLOOR
FLOOR
18"
N
NW
W
FLOOR
NURSE CALL PATIENT STATION
(PB - PUSH BUTTON, M - MICROPHONE, K -KEYED, HS - HIGH SECURITY STEEL
COVER PLATE)
42"
HEADWALL
/40"
HEADWALL
/40"
CEILING
DESK/ 42"
HEADWALL
/40"
M
DATA OUTLET - 4-4 PR UTP
DATA OUTLET - 4-4 PR UTP, 1-COAX - OPTIONAL, 1 - FIBER - OPTIONAL
DATA OUTLET - 1-4 PR UTP
TELCO OUTLET - 1-4 PR UTP
WALL PHONE
WIRELESS ACCESS POINT - 2 - 4 PR UTP
TV OUTLET - CEILING MOUNTED
TV OUTLET - WALL MOUNTED
NURSE CALL EQUIPMENT CABINET
NURSE CALL AUXILIARIES
NURSE CALL CODE BLUE STATION WITH CLEAR BUTTON COVER
NURSE CALL DUTY STATION
NURSE CALL MASTER STATION/CONSOLE
NURSE CALL DOME LIGHT - WALL MOUNTED
(Z - ZONE LIGHT, V - VANDAL RESISTANCE)
NURSE CALL PATIENT BED INTERFACE RECEPTACLE
STAFF ASSIST/ CODE BUTTON WITH CLEAR PLASTIC COVER
(P - PUSH FOR HELP, HS - HIGH SECURITY STEEL COVER PLATE, X - NO CLEAR
BUTTON COVER)
NURSE CALL STAFF TERMINAL
NURSE CALL WIRELESS ANTENNAS
NURSE CALL WIRELESS PENDANT
TWO POST OIT EQUIPMENT RACK
FOUR POST EQUIPMENT RACK
OIT EQUIPMENT RACK
FLOOR
D
B
A
C
E
N
R
P
T
S
N
N
NCE
A
TECHNOLOGY SYMBOL LINE TYPE
EXPLANATIONS
SYMBOLS THAT ARE GRAY OR HALF-TONE IN APPEARANCE ARE DEVICES THAT ARE EXISTING TO REMAIN.
THESE LINES MATCH THE TONE OF THE BUILDING'S LINES. THESE SYMBOLS CAN APPEAR ON SHEETS
WITH EITHER DEMOLITION OR NEW WORK PLANS. THEY ARE TYPICALLY ACCOMPANIED WITH A SHEET
NOTE OR KEY NOTE.
A
SYMBOLS THAT ARE DARK AND/OR DASHED IN APPEARANCE ARE DEVICES THAT ARE EXISTING TO BE
DEMOLISHED. THESE SYMBOLS SHOULD ONLY APPEAR ON DEMOLITION SHEETS UNLESS NOTED
OTHERWISE.
A
SYMBOLS THAT ARE DARK IN APPEARANCE AND ARE NOT DASHED ARE NEW DEVICES TO BE
INSTALLED. THESE SYMBOLS SHOULD ONLY APPEAR ON SHEETS WITH NEW WORK PLANS UNLESS
NOTED OTHERWISE.
TYPICAL
SYMBOL
DESCRIPTION
NURSE CALL SYMBOLS, NOTES AND
ABBREVIATIONS
ADO AUTOMATIC DOOR OPERATOR
AFF ABOVE FINISH FLOOR
CCTV CLOSED CIRCUIT TELEVISION
COAX COAXIAL CABLE
COMM COMMUNICATION
COR CONTRACTING OFFICER
REPRESENTATIVE
DC DOOR CONTACT SWITCH
DN DOWN
DO DOOR OPERATOR
DVR DIGITAL VIDEO RECORDER
EEB EMERGENCY EXIT BUTTON
EL ELECTRICAL STRIKE
FA FIRE ALARM
FAP FIRE ALARM PANEL
FAAP FIRE ALARM ANNUNCIATOR PANEL
FO FIBER OPTIC
IT INTERCOMMUNICATION ROOM
MATV MASTER ANTENNA TELEVISION
MM MULTI MODE FIBER
NAC NETWORK APPLIANCE CIRCUIT PANEL
NS NO SCALE
NTS NOT TO SCALE
NVR NETWORK VIDEO RECORDER
TECHNOLOGY ABBREVIATIONS LIST
OC ON CENTER
OIT OFFICE OF INFORMATION TECHNOLOGY
PACS PHYSICAL ACCESS CONTROL SYSTEM
PAMN PUBLIC ADDRESS AND MASS NOTIFICATION SYSTEM
PB PUSH BUTTON
PDU RACK POWER DISTRIBUTION UNITS
POE POWER OVER ETHERNET
PR PAIR
RX REQUEST TO EXIT
SEP SERVICE ENTRANCE PROTECTION
SLC SIGNALING LINE CIRCUIT
TEL TELEPHONE
TGB TELECOMM GROUND BUS BAR
TM TELEMONITORING
TMGB TELECOMM MAIN GROUND BUS BAR
TP TWISTED PAIR
TR TELECOMM ROOM
TTB TELEPHONE TERMINAL BOARD
TV TELEVISION
WM WIRE MANAGEMENT
WAP WIRELESS ACCESS POINT
UL UNDERWRITERS LABORATORY
UPS UNINTERRUPTIBLE POWER SUPPLY
UTP UNSHIELDED TWISTED PAIR
N NEW DEVICES
NCA NETWORK CONTROL ANNUNCIATOR
DVC DIGITAL VOICE COMMAND
SS STAINLESS STEEL
E EXISTING DEVICES
BOD BASIS OF DESIGN
CLG CEILING
EG EQUIPMENT GROUND
NCE NURSE CALL EQUIPMENT
SM SINGLE MODE FIBER
CATV CABLE TELEVISION
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
321 4 5 6 7
A B
C E
Dwg. of
LocationLocation
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
Revisions: Date
CONSULTANTS:
ADR
REPLACE NURSE CALL
SYSTEM
659-20-201
20-091
CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
© COPYRIGHT Apogee Consulting Group, P.A.
2, 5, 8, 21
29JVE
Engineers Architects
U.S. Department of Veterans Affairs
W.G. (BILL) HEFNER VAMC
SALISBURY, NC 28144
N
O
T
F
R
C
O
N
S
T
R
U
C
T
I
O
N
N
R
C
O
N
S
T
R
U
C
T
I
O
N
FEBRUARY 10, 2021
NC License #: C-1848
T-001
UNO UNLESS NOTED OTHERWISE
TECHNOLOGY GENERAL NOTES
1. ALL COMMUNICATIONS DEVICES AND EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE
WITH THE PROJECT SPECIFICATIONS, THE MANUFACTURER'S RECOMMENDED
PROCEDURES, ALL APPLICABLE LOCAL AND STATE CODES, AMERICANS WITH DISABILITIES
ACT AND WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE, BICSI
STANDARDS, VA TELECOMMUNICATIONS AND SPECIAL TELECOMMUNICATION SYSTEMS
DESIGN MANUAL.
2. FIRESTOP, DRAFTSTOP, SMOKESTOP AND/OR PROTECT THE ANNULAR SPACE AROUND
ALL PENETRATIONS THROUGH WALLS, PARTITIONS, FLOORS, CEILINGS, AND ROOF IN
ACCORDANCE WITH THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE, UL LISTING
REQUIREMENT AND THE APPLICABLE BUILDING CODES.
3. PROVIDE DRAWINGS SHOWING ALL PENETRATIONS. ALL CABLING SHALL COMPLY WITH
THE LATEST EDITION OF TELECOMMUNICATIONS DISTRIBUTION METHOD MANUAL AND
ANSI/TIA/EIA PUBLICATIONS.
4. COMPLY WITH THE LATEST ANSI/TIA/EIA 607 - STANDARD FOR
TELECOMMUNICATION BONDING COMMERCIAL BUILDING.
5. COMPLY WITH THE LATEST ANSI/TIA/EIA 568 - 2006 STANDARD FOR INSTALLATION
COMMERCIAL BUILDING TELECOMMUNICATIONS CABLING.
6. COMPLY WITH THE LATEST ANSI/TIA/EIA 569 - COMMERCIAL BUILDING STANDARD FOR
TELECOMMUNICATIONS PATHWAYS AND SPACES.
7. COMPLY WITH THE LATEST NFPA 70 NATIONAL ELECTRICAL CODE.
8. COMPLY WITH THE LATEST NFPA 99 HEALTHCARE FACILITIES CODE.
9. COMPLY WITH THE LATEST NFPA 101 LIFE SAFETY CODE.
10. COMPLY WITH THE LATEST OIT DESIGN GUIDE.
11. COORDINATE ANY AND ALL WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION SO
AS TO AVOID CONFLICT DURING CONSTRUCTION.
12.
13.
MOUNTING HEIGHTS INDICATED ARE TO CENTER OF DEVICE, BOXES, OUTLET, OR
EQUIPMENT UNLESS NOTED OTHERWISE.
14.
ALL CONDUITS SHALL BE RGS OR EMT UNLESS OTHERWISE NOTED.
15.
ALL MATERIALS, DEVICES, APPLIANCES AND EQUIPMENT SHALL BE LABEL LISTED BY AN
APPROVED THIRD PARTY TESTING AGENCY.
16.
ANY DISCREPANCY BETWEEN PLANS AND SPECIFICATIONS SHALL BE BROUGHT TO THE
ATTENTION OF THE VA COR, ARCHITECT, AND ENGINEER OF RECORD FOR CLARIFICATION.
THE MORE STRINGENT OF THE THEM SHALL TAKE PRECEDENCE.
17.
18.
ALL COPPER OUTLETS/CONNECTORS SHALL BE TIA/EIA CAT 6A.
19.
ALL WORK AREA OUTLETS SHALL BE 8 PIN, CAT 6A KEYSTONE JACK WIRED PER T568B AS
DIRECTED BY THE VA COR.
20.
LABELING SHALL BE ACCORDING TO LATEST ANSI/TIA 606A&B EDITION AS WELL AS THE
STANDARDS SET FORTH BY VA HOSPITAL OIT.
INSTALL NURSE CALL SYSTEM PER VA TELECOMMUNICATIONS AND SPECIAL
TELECOMMUNICATIONS SYSTEMS DESIGN MANUAL.
PROGRAM ALL NURSE CALL SYSTEM PER VA REQUIREMENT FOR EACH AREA.
A. CONTRACTOR SHALL COORDINATE WORK IN PATIENT ROOM(S)/
WING(S)/ BUILDING(S) OR OTHER AREAS WITH THE NURSE MANAGER
AND COR PRIOR TO ANY WORK.
B. ROOM(S) WILL BE TURNED OVER TO THE CONTRACTOR FOR WORK AND
WILL BE AT THE DIRECTION OF THE NURSE MANAGER AND COR.
C. THE NURSE CALL WORK SHALL BE DONE ON ONE OR TWO PATIENT
ROOM(S) AT A TIME.
D. AFTER THE FIRST PATIENT ROOM(S) ARE COMMISSIONED ON THE NEW
NURSE CALL SYSTEM, THE CONTRACTOR CAN MOVE TO THE NEXT SET
OF PATIENT ROOM(S).
E. WORK SHALL BE LIMITED TO ONE OF THE WINGS AT A TIME.
F. PRIOR TO CONDUCTING WORK WITHIN SPECIFIC WINGS THE
CONTRACTOR SHALL DO THE FOLLOWING:
F.1. INSTALL NURSE CALL EQUIPMENT CABINETS.
F.2. INSTALL NURSE CALL CONSOLES.
F.3. CONNECT NURSE CALL EQUIPMENT CABINETS TO THE VA IT
NETWORK.
F.4. INSTALL NEW NURSE CALL CABLING IN EXISTING RACEWAY UNLESS
OTHERWISE INDICATED ON THE DRAWINGS.
F.5. COMMISSION NEW MASTER CONSOLE AND REMOTE CONSOLES AND
TRAIN STAFF ON FLOOR IN OPERATION OF THE NEW SYSTEM.
F.6. REPLACE ALL NURSE CALL DEVICES WITH NEW DEVICES IN EACH
PATIENT ROOM(S) AND COMMISSION THESE DEVICES.
F.7. REPEAT PROCESS ON WING UNTIL COMPLETE.
F.8. REPEAT PROCESS FOR OTHER WINGS, UNTIL ALL WORK IS
COMPLETE.
F.9. PERFORM FINAL TEST OF THE COMPLETED SYSTEM INCLUDING ALL
NURSE CALL STATIONS, DEVICES, WIRING, TV INTERFACE, AND
LIGHTING INTERFACE. PROVIDE A SPREAD SHEET FOR EACH TASK
ON AN EXCEL SPREAD SHEET.
F.10. ONCE ALL ROOMS FOR ALL FLOORS ARE COMPLETE, THEN REMOVE
THE EXISTING NURSE CALL EQUIPMENT CABINET, MASTER
CONSOLE AND TURN OVER ALL EXISTING NURSE CALL EQUIPMENT
AND DEVICES TO THE VA/COR.
PHASING NOTES
OWNER FURNISHED EQUIPMENT
SCOPE OF WORK
1. RAULAND ENTERPRISE PLATFORM INTEGRATION AND TESTING OF SOFTWARE PROVIDED
BY VA.
2. INSTALLATION AND ALL HARDWARE SHALL BE PROVIDED BY THE GENERAL CONTRACTOR.
02/10/2021
8 8
1. MAIN SERVER ROOM IN BUILDING 5 - ROOM 1012A.
2. NEW NURSE CALL ENTERPRISE PLATFORM FILE
SERVER IN EXISTING BIO-MED DATA RACK
BUILDING 21 - ROOM BA-122.
3. RUN FIBER THROUGH EXISTING WALL
PENETRATION INTO CORRIDOR ABOVE CEILING
TILES.
4. RUN FIBER THROUGH EXISTING 2" CONDUIT ABOVE
CEILING IN BUILDING 2 AND 4. REMOVE EXISTING
CABLING IN CONDUIT.
5. HARD CEILING IN TUNNEL CONNECTING BUILDINGS
4 AND 2. EXISTING 2" CONDUIT ABOVE CEILING.
6. PROVIDE 3" CONDUIT FOR CABLING IN BUILDING 8
AND TUNNEL CONNECTING BUILDING 8 TO
BUILDING 21.
7. DROP IN CEILING IN HALLWAY. PROVIDE "J-HOOKS"
2' O.C. FOR HORIZONTAL, ABOVE CEILING CABLING.
SEE SECTION 27 10 00 SUBSECTION 3.1 FOR MORE
INFORMATION.
8. NEW NURSE CALL EQUIPMENT CABINET.
9. PROVIDE UL LISTED FIRE STOP FOR CONDUIT
PENETRATIONS THROUGH RATED WALL.
A. ROUTING SHOWN IS PRIMARILY FOR HORIZONTAL
ROUTING IN AND BETWEEN BUILDINGS. FOR
ROUTING UP TO VARIOUS FLOORS WITHIN
BUILDINGS REFER TO 1/TK601.
B. ROUTING SHOWN (INCLUDING ROUTING THROUGH
BUILDINGS) IS CONCEPTUAL ONLY. DETERMINE
EXACT FIELD ROUTING.
C. INSTALL FIBER PER DETAILS (TK501).
D. PROVIDE PULL BOXES AS REQUIRED UNLESS
OTHERWISE NOTED OR APPROVED.
E. PROVIDE A SINGLE SEGMENT OF FIBER WITH NO
SPLICES BETWEEN EACH NURSE CALL CABINET
TERMINATION. IF A SINGLE UN-SPLICED SEGMENT
IS NOT POSSIBLE, PROVIDE FUSION SPLICES IN
ENCLOSURES. SPLICES ARE NOT PERMITTED IN
MANHOLES. PROVIDE EACH PROPOSED SPLICE
LOCATION WITH SHOP DRAWING SUBMITTALS.
F. REFER TO NURSE CALL RISER 1/TK601 FOR
ADDITIONAL INFORMATION.
G. PATCH ALL PENETRATIONS AND OPENINGS IN
SMOKE AND FIRE WALLS WITH APPROVED UL
LISTED MATERIALS.
NEW NURSE CALL NETWORK CABLE ROUTING
1" = 100'
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
SHEET NOTES:
SHEET KEY NOTES:
321 4 5 6 7
A B
C E
Dwg. of
LocationLocation
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
Revisions: Date
CONSULTANTS:
FEBRUARY 10, 2021
ADR
UPGRADE NURSE CALL
SYSTEM
659-20-201
20-091
CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
© COPYRIGHT Apogee Consulting Group, P.A.
29JVE
Engineers Architects
U.S. Department of Veterans Affairs
W.G. (BILL) HEFNER VAMC
SALISBURY, NC 28144
N
R
C
O
N
S
T
R
U
C
T
I
O
N
N
R
C
O
N
S
T
R
U
C
T
I
O
N
BID ALTERNATES:
NC License #: C-1848
TS101
NEW NURSE CALL NETWORK
CABLE ROUTING
N
O
R
T
H
50 100 2000
2, 5, 8, 21
1. ALTERNATE 1 - SEE G-002
BUILDINGS NOT IN
SCOPE OF WORK
BUILDINGS IN
SCOPE OF WORK
02/10/2021
STAIRS
XRAY
CONTROL RM
DRESSING
XRAY
CONT RM
DRESSING
XRAY
FILM PROCESS
WORK ROOM
CT SCANNER
XRAY
HALLWAY
CT OPER.
CLEAN STOR
2110A
OFFICE
2110B
OFFICE
EXAM
TOILET
2110C
WAITING
NUC MED
NUC MED
CONFERENCE
WAITING ROOM
OFFICE
2098A
OFFICE
2098B
OFFICE
2098C
OFFICE
2098D
OFFICE
2098E
OFFICE
2098F
OFFICE
OFFICE
OFFICE
GEN STOR
TOILET
TOILET
D/W
EXAM
EXAM
EXAM
OFFICE
OFFICE
TLT
STAIRS
WAITING ROOM
TOILET
GEN STOR
TOILET
OFFICE
OFFICE
TLT
OFFICE
OFFICE
TLT
EXAM
FEC
TOILET
EXAM
CLEAN SUP
TOILET
OFFICE
HAC
TLT
CLOSET
2059A
TOILET
EXAM
EXAM
OFFICE
LOCK
COMPUTER ROOM
OFFICE
OFFICE
BLOOD BANK
HEMATOLOGY
STAIRS
2155A
OFFICE
2153B
OFFICE
LINEN CHUTE
OFFICE
OFFICE
LOCKERS
TOILET
LOCKERS
TLT
ELECT
TOILET
2168A
TEL
STORAGE
TOIL.
TLT
TLT
TLT
BREAK ROOM
OFFICE
HAC
CONT RM
2130A
ELECT
FEC
ELECT.
2098G
BATHROOM
2098I
CLOSET
2095A
GEN STOR.
2098H
RECEPT.
FAC
WAITING
2107A
HOT LAB
2090A
OFFICE
BONE DENS
EXAM
2027A
Corridor
CT SCANNER 2
HAC
CORRIDOR
LAB
LAB
F. STAFF
TLT
LOCKERS
S
W
K
S
N
F
I
C
E
CHIEF OFFICE
OFFICE
OFFICE
OFFICE
CORRIDOR
OFFICE
A
H
A
L
Y
HALL WAY
HALL WAY
2030A
TECH WKSTN
STAIRS
R
O
O
F
BLOOD
STAGING
WAITING
BLOOD
DRAW
BLOOD
DRAW
BLOOD
DRAW
STORAGE
2133A
ELE CLST
CORRIDOR
ELEC
CORRIDOR
CORRIDOR
FEC
STAIRS
STAIRS
LINEN CHUTE
2161A
OFFICE
B WING CENTER WING CENTER WING A WING
BREAK AREA
FEC
TELE
SPECIMEN TLT
SPECIMEN TLT
PIPE CHASE
FLEX SPACE
EXAM
EXAM
EXAM
TREADMILL 2
NURSE
WORK
TREADMILL 1
ECHO
READING
ASST.
CHIEF
PHYS.
WKRM
ECHO 1
STORAGE
ECHO WORK
ECHO 2
EXAM
EXAM
EKG
EKG
HOLTER
EXISTING
TOILET
CORRIDOR
STORAGE
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
321 4 5 6 7
A B
C E
Dwg. of
LocationLocation
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
Revisions: Date
CONSULTANTS:
ADR
UPGRADE NURSE CALL
SYSTEM
659-20-201
20-091
CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
© COPYRIGHT Apogee Consulting Group, P.A.
29JVE
Engineers Architects
U.S. Department of Veterans Affairs
W.G. (BILL) HEFNER VAMC
SALISBURY, NC 28144
N
R
C
O
N
S
T
R
U
C
T
I
O
N
N
R
C
O
N
S
T
R
U
C
T
I
O
N
FEBRUARY 10, 2021
NC License #: C-1848
1 BUILDING 2 - SECOND FLOOR NURSE CALL OVERALL PLAN
SCALE: 1/16" = 1' 0"
02T-120
BUILDING 2 - SECOND FLOOR
NURSE CALL OVERALL PLAN
02TD121
02TD121
02TN121
02TN121
N
O
R
T
H
8 16 320
AREA WITH NO
NURSE CALL
EQUIPMENT
02/10/2021
FAC
3165A
FAC
F A
C
CORR
3091A
TEL
STOR
CONF
3101A
OFFICE
OFFICE
BREAK
TLT
F.TLT
LAB.STO
WAITING
EQUIP STOR
CORR
3094A
OFFICE
3094K
OFFICE
3094J
OFFICE
3094B
OFFICE
3094L
GEN STOR
3094C
CONF RM
3094I
OFFICE
3094H
OFFICE
3094D
OFFICE
3094E
OFFICE
3094F
OFFICE
3094G
OFFICE
M.TLT
SOIL LN
MOP
EQUIP STORAGE
EKG
TLT
CL.UTIL
MECH RM
BARIATRIC
ROOM
HAC
WORK RM
MECH
PATIENT
ROOM
3110A
CHARTING
STATION
3110B
CHARTING
STATION
3006A
PATIENT
BATH
3005A
PATIENT
BATH
PATIENT
ROOM
ELEC
3125A
BARIATRIC
BATH
3126A
PATIENT
BATH
PATIENT
ROOM
CORRIDOR
PATIENT
ROOM
3127A
PATIENT
BATH
3128A
PATIENT
BATH
PATIENT
ROOM
3110C
CHARTING
STATION
3110D
CHARTING
STATION
PATIENT
ROOM
3003A
PATIENT
BATH
3004A
PATIENT
BATH
PATIENT RM
3003A
MECH RM
3001A
STAIR #1
CLEAN
UTILITY
STAFF WORKROOM
MEDICATION
3002A
STAIR #1
NURSE ST
STAIR #5
1-BED
1-BED
1-BED
1-BED
1-BED
1-BED
1-BED
1-BED
CORR
1-BED
1-BED
1-BED
LOCKER
OFFICE
OFFICE
BLD GAS
3160A
ELEC
TLT
DIST RM
SUPP
CORR
3161A
TELEPHONE
3163A
FAC
PIPE
CLEAN SUP
CLEAN SUP
EQUIP STOR
HAC
ELEC
F. TLT
M. TLT
EQUIP
STOR
TLT
TLT
TLT
TLT
EQUIP STOR
TLT
TLT
TLT
TLT
TLT
SOILED
UTILITY
STORAGE
EMS
NOUR.
OFFICE
CLEAN
LINEN
EQUIPMENT
STORAGE
ELEC
3121C
CHARTING
STATION
ANTE
ROOM
3113A
ISOLATION
BATH
3121A
STORAGE
ISOLATION
ROOM
CORRIDOR
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
3121B
CHARTING
STATION
3121A
CHARTING
STATION
3117A
PATIENT
BATH
PATIENT
ROOM
3115A
PATIENT
BATH
3114A
PATIENT
BATH
PATIENT RM
STAIR #4
STAIR #4
3116A
PATIENT
ROOM
3118A
PATIENT
BATH
3119A
PATIENT
BATH
PATIENT
ROOM
3121D
CHARTING
STATION
DIALYSIS
EQUIP STOR
CLEAN SUP
3039A
PAT. TLT
NOUR
3045A
EQUIP
PAT. ROOM
PAT. ROOM
PAT. ROOM
3054A
PAT. TLT
PAT. ROOM
PAT. ROOM
BARIATRIC
PAT. ROOM
PAT. ROOM
ISO. PAT. ROOM
ISO. PAT. ROOM
3043A
STAIR
3044A
STAIR
EQUIP. STOR
3040A
PAT. TLT
3045B
CORRIDOR
SOIL UTIL
ALCOVE
FAC
3042A
PAT. TLT
3051A
BARIATRIC
PAT. TLT
3043B
PAT. TLT
3050A
PAT. TLT
ANTE ISOL.
3044B
PAT. TLT
3045D
ALCOVE
ANTE ISOL
3058A
PAT. TLT
3059A
PAT. TLT
PAT. ROOM
CORRIDOR
NURSE STATION
STAIR #6
LINEN CHUTE
FAC
BARIATRIC
ROOM
EQUIPMENT
STORAGE
HAC
3082A
BARIATRIC
TLT
MEDICATION
PAT. ROOM
BARIATRIC
ROOM
3063A
PAT. TLT
3075A
BARIATRIC
TLT
3071C
CHARTING
STATION
3074A
PATIENT
TLT
3073A
PATIENT
TLT
3072A
PATIENT
TLT
3071A
CHARTING
STATION
3071B
CHARTING
STATION
3068A
PATIENT
TLT
3066A
PATIENT
TLT
3064A
PATIENT
TLT
CORR
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
ISO PAT
ROOM
ANT. ISO
STAIR #3
STAIR #3
3069A
STORAGE
ISO PAT
ROOM
ANT. ISO
PAT. ROOM
3072B
ALCOVE
TLT
3071A
ELEC
B WING CENTER WING CENTER WING A WING
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
321 4 5 6 7
A B
C E
Dwg. of
LocationLocation
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
Revisions: Date
CONSULTANTS:
ADR
UPGRADE NURSE CALL
SYSTEM
659-20-201
20-091
CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
© COPYRIGHT Apogee Consulting Group, P.A.
29JVE
Engineers Architects
U.S. Department of Veterans Affairs
W.G. (BILL) HEFNER VAMC
SALISBURY, NC 28144
N
R
C
O
N
S
T
R
U
C
T
I
O
N
N
R
C
O
N
S
T
R
U
C
T
I
O
N
FEBRUARY 10, 2021
NC License #: C-1848
1 BUILDING 2 - THIRD FLOOR NURSE CALL OVERLL PLAN
SCALE: 1/16" = 1' 0"
02T-130
BUILDING 2 - THIRD FLOOR
NURSE CALL OVERALL PLAN
02TD131
02TD132
02TD132
02TN131
02TN132
02TN132
N
O
R
T
H
8 16 320
AREA WITH NO
NURSE CALL
EQUIPMENT
02/10/2021
PRE OP
4017A
STORAGE
OFFICE
EXAM
EXAM
PH 2 RM 3
TLT/SHW
4017B
TLT
EXAM
EXAM
CORRIDOR
CORRIDOR
ELEC
GEN STORAGE
CLEAN SUPPLY
WASH ROOM
4013A
PAT. LOCKER
OPER. ROOM #1
STORAGE
MECH RM
SCRUB RM
SCRUB ROM
STORAGE
MECH
OPER. ROOM #2
OPER. ROOM #3
STAIRS
FAC
CORRIDOR
GEN STORAGE
GEN STORAGE
PH 1 PACU
4100A
EQUIP STORAGE
4100B
EQUIP STORAGE
TOILET
TOILET
STORAGE
SURGERY WAITING
OFFICE
FAC
ELECT CLS
TOILET
GEN STORAGE
TOILET
PASS
HAC
TOILET
OFFICE
UTILITY
STORAGE
LINEN
4154A
TELE
D/W
ELECT
PH 1 PACU
OFFICE
RECEPTION
EQUIP STOR
NURSE STATION
CORRIDOR
TELECOM
STAIRS #6
NOUR. RM
CONTROL
CORRIDOR
BREAKROOM
CORRIDOR
OFFICE
CORRIDOR
ICU
HAC
ICU EQUIP
STAFF TOILET
LOCKER RM
ON-CALL
CLEAN LINEN
STORAGE
4058A
BATH
RESP OFFICE
BREAK/CONF ROOM
CORRIDOR
RESP EQUIPMENT
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
STAIR #3
ISOLATION ICU
SOIL UTILITY
ANTE
ISOLATION-ICU
PACU
ICU
CORRIDOR
STORAGE
DISTRIBUTION
ICU
ICU
ICU
ICU
STAIR #2
MED ROOM
WOMEN'S LOCKERS
MEN'S LOCKERS
TOILET
TOILET
STAIRS
4110B
CORRIDOR
4110A
CORRIDOR
4129A
DICTATION
CASE CART
MED GAS
SOILED UTILITY
PATIENT HOLDING
CLEAN UTILITY
SOILED
TOILET
LINEN CHUTE
MINOR OR
ELEC
4152B
MINOR OR
STAFF WORKSTATION
OR #5
SUB STERILE
OR #6
SURGICAL CORRIDOR
OR #7
EQUIP STORAGE
ELECTRICAL
EQUIP. STORAGE
HAC
STAIRS
CORR
PACU
B WING CENTER WING CENTER WING A WING
STORAGE
STORAGE
STORAGE
STORAGE
STORAGE
STORAGE
4130A
TOILET
4131A
TOILET
4132A
TOILET
4129A
TOILET
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
321 4 5 6 7
A B
C E
Dwg. of
LocationLocation
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
Revisions: Date
CONSULTANTS:
ADR
UPGRADE NURSE CALL
SYSTEM
659-20-201
20-091
CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
© COPYRIGHT Apogee Consulting Group, P.A.
29JVE
Engineers Architects
U.S. Department of Veterans Affairs
W.G. (BILL) HEFNER VAMC
SALISBURY, NC 28144
N
R
C
O
N
S
T
R
U
C
T
I
O
N
N
R
C
O
N
S
T
R
U
C
T
I
O
N
FEBRUARY 10, 2021
NC License #: C-1848
1 BUILDING 2 - FOURTH FLOOR NURSE CALL OVERALL PLAN
SCALE: 1/16" = 1' 0"
02T-140
BUILDING 2 - FOURTH FLOOR
NURSE CALL OVERALL PLAN
02TD141
02TN141
N
O
R
T
H
8 16 320
AREA WITH NO
NURSE CALL
EQUIPMENT
02/10/2021
DN
STAIR
A135
PATIENT ROOM 15
A134
DOUBLE PATIENT
ROOM 14
A133
BATHROOM 15
A134A
BATHROOM 14
A133A
SECLUSION
A131
ANTE ROOM
A131A
TLT
A131B
SINGLE PATIENT
ROOM 13
A122
BATHROOM 12
A124A
BATHROOM 13
A122A
SINGLE PATIENT
ROOM 12
A124
DOUBLE PATIENT
ROOM 11
A126
BATHROOM 11
A126A
BATHROOM 10
A129A
DOUBLE PATIENT
ROOM 10
A129
SINGLE PATIENT
ROOM 9
A127
BATHROOM 8
A125A
BATHROOM 9
A127A
PATIENT ROOM 8
A125
SCREENED
PORCH 2
A123
GROUP ROOM
A121
BARIATRIC
BATHROOM 7
A112A
PAT TLT
A108
PAT TLT
A110
BARIATRIC
PATIENT ROOM 7
A112
SINGLE PATIENT
ROOM 6
A114
BATHROOM 6
A114A
BATHROOM 5
A116A
SINGLE PATIENT
ROOM 5
A116
DOUBLE PATIENT
ROOM 4
A118
BATHROOM 4
A118A
TV AREA
A117
BATHROOM 3
A115A
DOUBLE PATIENT
ROOM 3
A115
SINGLE PATIENT
ROOM 2
A113
BATHROOM 1
A111A
BATHROOM 2
A113A
PATIENT ROOM 1
A111
SCREENED
PORCH 1
A109LAUNDRY
A107
SECURE
VESTIBULE
A101
FAMILY
CONFERENCE
A102
CONSULT 1
A104
HALL
AC110
CONSULT 2
A106
OFFICE 7
A158
OFFICE 3
A159
OFFICE 4
A160
OFFICE 5
A161
ELEVATOR
VESTIBULE
A175
OFFICE 2
A156
OFFICE 1
A155
STAFF BREAK
A154
OFFICE 12
A153
OFFICE 11
A152
OFFICE 10
A151
OFFICE 9
A150
WARD CLERK
A120C
WORK ROOM
A120B
TEAM ROOM
A141
CLEAN STORAGE
A142
ST TLT
A144B
ST TLT
A144A
STAFF LOCKERS
A144
MEDICATION
A120A
CLEAN LINEN
A140
QUIET ROOM
A130
SHOWER
A132
CORRIDOR
AC104
ELECTRICAL 3
A146
COMM
A171
ELEVATOR 2
S2
ELEVATOR 1
S1
OFFICE 8
A157
OFFICE 6
A162
PATIENT
PROPERTY
A163
DAY
AC102B
DINING
AC103A
DAY
AC103B
SERVICE
CORRIDOR
AC106
PUBLIC
CORRIDOR
AC111
SOILED UTILITY
A145
HAC
A143
AIR HANDLER
ROOM
A172
LOBBY
A100
EXAM
A103
SERVING
A105
ELEVATOR
MACHINE ROOM
A170
STAIR 1
AS101
HALL
AC105
NURSING
STATION
A120
PATIENT
CORRIDOR
AC103
HALL
AC107
HALL
AC108
HALL
AC109
PATIENT
CORRIDOR
AC102
DINING
AC102A
ELECTRICAL 1
A173
ELECTRICAL 2
A174
GROUP ROOM
CLOSET
A121A
PATIENT
CORRIDOR
AC101
CORRIDOR
AC104A
A105A
ABOVE
SUB PORCH
(GROUP)
A121B
TV AREA
A128
STANDPIPE
CHASE
AS101A
ELEVATOR
P1
ELEVATOR
P2
ENTRY
VESTIBULE
SECURITY
OPEN TO ABOVE
OPEN
TO
ABOVE
HAS OFFICE
A L
I G
N
UP
TO BUILDING 4
TO BUILDING 4
UP
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
321 4 5 6 7
A B
C E
Dwg. of
LocationLocation
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
Revisions: Date
CONSULTANTS:
ADR
UPGRADE NURSE CALL
SYSTEM
659-20-201
20-091
CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
© COPYRIGHT Apogee Consulting Group, P.A.
29JVE
Engineers Architects
U.S. Department of Veterans Affairs
W.G. (BILL) HEFNER VAMC
SALISBURY, NC
N
R
C
O
N
S
T
R
U
C
T
I
O
N
N
R
C
O
N
S
T
R
U
C
T
I
O
N
FEBRUARY 10, 2021
NC License #: C-1848
1 BUILDING 8 - FIRST FLOOR NURSE CALL OVERALL PLAN
SCALE: 1/16" = 1' 0"
08T-110
BUILDING 8 - FIRST FLOOR
NURSE CALL OVERALL PLAN
08TD111
08TD111
08TN111
08TN111
N
O
R
T
H
8 16 320
AREA WITH NO
NURSE CALL
EQUIPMENT
02/10/2021
UPDN
DN
DOUBLE
PATIENT ROOM
A229
TV AREA
A228
SCREENED
PORCH 1
A209
PATIENT ROOM
A211
BATHROOM 1
A211A
SINGLE
PATIENT ROOM
A213
BATHROOM 2
A213A
DOUBLE
PATIENT ROOM
A215
BATHROOM 3
A215A
TV AREA
A217
DOUBLE
PATIENT ROOM
A218
BATHROOM 4
A218A
SINGLE
PATIENT ROOM
A216
BATHROOM 5
A216A
SINGLE
PATIENT ROOM
A214
BATHROOM 6
A214A
BARIATRIC
PATIENT ROOM
A212
BARIATRIC
BATHROOM 7
A212A
Clean
Linen
A210
Nourish
A208
GROUP ROOM
A221
GROUP ROOM
CLOSET
A221A
SUB PORCH
(GROUP)
A221B
SCREENED
PORCH 2
A223
PATIENT ROOM
A225
SINGLE
PATIENT ROOM
A227
BATHROOM 9
A227A
BATHROOM 8
A225A
BATHROOM 10
A229A
BATHROOM 11
A226A
DOUBLE
PATIENT ROOM
A226
SINGLE
PATIENT ROOM
A224
BATHROOM 12
A224A
BATHROOM 13
A222A
SINGLE
PATIENT ROOM
A222
TLT
A231B
ANTE ROOM
A231A
SECLUSION
A231
DOUBLE
PATIENT ROOM
A233
BATHROOM 14
A233A
BATHROOM 15
A234A
PATIENT ROOM
A234
ELECTRICAL 3
A246
SOILED UTILITY
A245
SHOWER
A232
HAC
A243
QUIET ROOM
A230
STAFF
LOCKERS
A244
STAFF BREAK
A254
OFFICE 12
A253
OFFICE 11
A252
OFFICE 10
A251
OFFICE 9
A250
CLEAN
STORAGE
A242
TEAM ROOM
A241
WORK ROOM
A220B
WARD CLERK
A220C
MEDICATION
A220A
ST TLT
A244B
ST TLT
A244A
NURSING
STATION
A220
OFFICE 1
A255
OFFICE 2
A256
OFFICE 8
A257
PATIENT
PROPERTY
A263
OFFICE 7
A258
OFFICE 6
A262
OFFICE 3
A259
OFFICE 4
A260
OFFICE 5
A261
FAMILY
CONFERENCE
A202
CONSULT 1
A204
CONSULT 2
A206
SERVING
A205
EXAM
A203
SECURE
VESTIBULE
A201
COMM
A271
AIR HANDLER
ROOM
A272
DAY
AC202B
DINING
AC202A
DINING
AC203A
DAY
AC203B
PATIENT
CORRIDOR
AC202
LAUNDRY
A207
PATIENT
CORRIDOR
AC203
HALL
AC207
HALL
AC208
HALL
AC210
HALL
AC209
CORRIDOR
AC204
CORRIDOR
AC204A
HALL
AC205 CLEAN LINEN
A240
SERVICE
CORRIDOR
AC206
ELEVATOR
VESTIBULE
A275
STORAGE
A276
STORAGE
A273A
FEMALE PUBLIC
TOILET
A277
STAIR 1
AS201
EXIST.
ELEVATOR 2
P2
EXIST.
ELEVATOR 1
P1
MALE PUBLIC
TOILET
A278
GROUP ROOM
A273
PUBLIC
CORRIDOR
AC211
ELEVATOR
VESTIBULE
A274
EXIST ELEV
S1
EXIST ELEV
S2
STAIR 2
AS202
HAC
A280
PUBLIC
CORRIDOR
AC212
A205-A
OPEN TO BELOW
OPEN TO BELOW
FUTURE
CONFERENCE
ROOM
A279
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
321 4 5 6 7
A B
C E
Dwg. of
LocationLocation
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
Revisions: Date
CONSULTANTS:
ADR
UPGRADE NURSE CALL
SYSTEM
659-20-201
20-091
CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
© COPYRIGHT Apogee Consulting Group, P.A.
29JVE
Engineers Architects
U.S. Department of Veterans Affairs
W.G. (BILL) HEFNER VAMC
SALISBURY, NC
N
R
C
O
N
S
T
R
U
C
T
I
O
N
N
R
C
O
N
S
T
R
U
C
T
I
O
N
FEBRUARY 10, 2021
NC License #: C-1848
1 BUILDING 8 - SECOND FLOOR NURSE CALL OVERALL PLAN
SCALE: 1/16" = 1' 0"
08T-120
BUILDING 8 - SECOND FLOOR
NURSE CALL OVERALL PLAN
08TD121
08TD122
08TD121
08TN121
08TD122
08TN121
N
O
R
T
H
8 16 320
AREA WITH NO
NURSE CALL
EQUIPMENT
02/10/2021
SINGLE
PATIENT ROOM
A316
BATHROOM 5
A316A
SINGLE
PATIENT ROOM
A314
BATHROOM 6
A314A
BARIATRIC
PATIENT ROOM
A312
PAT TLT
A310
CLEAN
LINEN
A308
GROUP ROOM
CLOSET
A321A
EXERCISE
ROOM
A323
PATIENT ROOM
A325
SINGLE
PATIENT ROOM
A322
TLT
A331B
ANTE ROOM
A331A
QUIET ROOM
A330
OFFICE 9
A350
TEAM ROOM
A341
WORK ROOM
A320B
MEDICATION
A320A
DAY
AC302B
WARD CLERK
A320C
GROUP ROOM
A321
BARIATRIC
BATHROOM
A312A
DINING
AC302A
CLEAN LINEN
A340
DINING
AC303A
NURSE
STATION
A320
PATIENT
CORRIDOR
AC303
SECLUSION
A331
DN
AIR HANDLER
ROOM
A372
STORAGE
A373A
MALE PUBLIC
TOILET
A378
GROUP ROOM
A373
EXIST
ELEVATOR 1
P1
EXIST.
ELEVATOR 2
P2
ELEVATOR
VESTIBULE
A374
PUBLIC
CORRIDOR
AC312
STAIR 2
AS302
HAC
A380
FEMALE TOILET
A377
EXIST ELEV
S1
EXIST ELEV
S2
DOUBLE
PATIENT ROOM
A329
TV AREA
A328
SCREENED
PORCH 1
A309
PATIENT ROOM
A311
BATHROOM 1
A311A
SINGLE
PATIENT ROOM
A313
BATHROOM 2
A313A
DOUBLE
PATIENT ROOM
A315
BATHROOM 3
A315A
TV AREA
A317
DOUBLE
PATIENT ROOM
A318
BATHROOM 4
A318A
SINGLE
PATIENT ROOM
A327
BATHROOM 9
A327A
BATHROOM 8
A325A
BATHROOM 10
A329A
BATHROOM 11
A326A
DOUBLE
PATIENT ROOM
A326
SINGLE
PATIENT ROOM
A324
BATHROOM 12
A324A
BATHROOM 13
A322A
DOUBLE
PATIENT ROOM
A333
BATHROOM 14
A333A
BATHROOM 15
A334A
ELECTRICAL 3
A346
SOILED UTILITY
A345
SHOWER
A332
HAC
A343
STAFF
LOCKERS
A344
STAFF BREAK
A354
OFFICE 12
A353
OFFICE 11
A352
OFFICE 10
A351
CLEAN
STORAGE
A342
ST TLT
A344B
ST TLT
A344A
OFFICE 1
A355
OFFICE 2
A356
OFFICE 8
A357
PATIENT
PROPERTY
A363
OFFICE 7
A358
OFFICE 6
A362
OFFICE 3
A359
OFFICE 4
A360
OFFICE 5
A361
FAMILY
CONFERENCE
A302
CONSULT 1
A304
CONSULT 2
A306
EXAM
A303
LAUNDRY
A307
HALL
AC307
HALL
AC308
HALL
AC310
HALL
AC309
CORRIDOR
AC304A
HALL
AC305
SERVICE
CORRIDOR
AC306
ELEVATOR
VESTIBULE
A375
PATIENT ROOM
A334
PUBLIC
CORRIDOR
AC311
STAIR 1
AS301
COMM
A371
SECURE
VESTIBULE
A301
SERVING
A305
CORRIDOR
AC304
DAY
AC303B
PATIENT
CORRIDOR
AC302
A305-A
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
321 4 5 6 7
A B
C E
Dwg. of
LocationLocation
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
Revisions: Date
CONSULTANTS:
ADR
UPGRADE NURSE CALL
SYSTEM
659-20-201
20-091
CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
© COPYRIGHT Apogee Consulting Group, P.A.
29JVE
Engineers Architects
U.S. Department of Veterans Affairs
W.G. (BILL) HEFNER VAMC
SALISBURY, NC
N
R
C
O
N
S
T
R
U
C
T
I
O
N
N
R
C
O
N
S
T
R
U
C
T
I
O
N
FEBRUARY 10, 2021
NC License #: C-1848
1 BUILDING 8 - THIRD FLOOR NURSE CALL OVERALL PLAN
SCALE: 1/16" = 1' 0"
08T-130
BUILDING 8 - THIRD FLOOR
NURSE CALL OVERALL PLAN
08TD131
08TD131
08TN131
08TN131
N
O
R
T
H
8 16 320
AREA WITH NO
NURSE CALL
EQUIPMENT
02/10/2021
121 SF
78 SF
PIPE CHASE
B WING A WING A WING C WING
BA-122
OI&T COMPUTER RM
CB-7
CORRIDOR
CB-4
CORRIDOR
CB-1
CORRIDOR
CB-2
CORRIDOR
CB-3
CORRIDOR
CB-5
CORRIDOR
BB106
STAIRWELL
BA-121
STAIRWELL
BB-149
OFFICE
BB-145
OFFICE
BB-144
OFFICE
BB-142
OFFICE
BB-141
OFFICE
BB-140
OFFICE
BB-139
OFFICE
BB-138
OFFICE
BB-137
OFFICE
BB-136
OFFICE
BB-135
OFFICE
BB-134
OFFICE
BB-133
OFFICE
BB-132
OFFICE
BB-152
OFFICE
BB-151
OFFICE
BB-150
OFFICE
BB-148
OFFICE
BB-146
OFFICE
BB-143
OFFICE
BB-131
OFFICE
CB-6
CORRIDOR
BB-105
MECHANICAL
BB-104
ELEC
BB-103
TELE
BB-100A
PIPE CHASE
BB-111
VESTIBULE
BB-112
BATH
BB-130
BATHROOM
BB-129
BATHROOM
BB-125
Storage
BB-128
OFFICE
BB-106
OFFICE
BB-107
OFFICE
BB-108
OFFICE
BB-109
OFFICE
BB-110
OFFICE
BB-113
Command Room
BB-114
OFFICE
BB-115
OI&T STORAGE
BB-118
GEN STORAGE
BB-117
OFFICE
BB-127
OFFICE
BB-126
OFFICE
BB-119
OFFICE
BB-120
OFFICE
BB-124
OFFICE
BB-123
OFFICE
BB-122
OFFICE
BB-121
OFFICE
BB-101
LINEN CHUTE
BB-100
STORAGE
BA-110A
OFFICE
BA-110
OFFICE
BA111A
BA-122A
OI&T
BB-102
Entrance
BA101
ELECT.CLOSET
BA-103
OFFICE
BA102
OFFICE - EMS
BA100
ELEV.EQ.RM.
BA111
BA112B
OI&T
BA112A
OI&T
BA112
GEN STORAGE
BC100A
OFFICE
BC100B
OFFICE
BC100C
OFFICE
BC100
OFFICE
BC101
OFFICE
BC102E
LOGISTICS
BC102D
CONF.RM.
BC102A
LOGISTICS
BC102B
LOGISTICS
BC102C
LOGISTICS
BC102F
LOGISTICS
BC102
LOGISTICS OFFICES
BC105
OFFICE
BC106
RECEIVING
BC107
OFFICE
BC108
OFFICE
BC109
MECHANICAL ROOM
STAIRWELL
BC111
H.A.C.
BC113
F.TLT.
BC114
M.TLT.
B C
B A
T C
H A
R R
M
BC112
OFFICE
BC110
OFFICE
B C
B R
E A
K R
O O
M
BC119
ELEC. CLOSET
BC118
TEL. CLOSET
BC116
ELECT. SWITCHGEAR RM.
BC120
SOILED LINEN
BC121
MECHANICAL ROOM
BC-122
GEN STORAGE
BA-120
OFFICE
BA-121
OFFICE
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
321 4 5 6 7
A B
C E
Dwg. of
LocationLocation
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
Revisions: Date
CONSULTANTS:
ADR
UPGRADE NURSE CALL
SYSTEM
659-20-201
20-091
CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
© COPYRIGHT Apogee Consulting Group, P.A.
29JVE
Engineers Architects
U.S. Department of Veterans Affairs
W.G. (BILL) HEFNER VAMC
SALISBURY, NC
N
R
C
O
N
S
T
R
U
C
T
I
O
N
N
R
C
O
N
S
T
R
U
C
T
I
O
N
FEBRUARY 10, 2021
NC License #: C-1848
1 BUILDING 21 - GROUND FLOOR NURSE CALL OVERALL PLAN
SCALE: 1/16" = 1' 0"
21T-100
BUILDING 21 - GROUND FLOOR
NURSE CALL OVERALL PLAN
TK401
N
O
R
T
H
8 16 320
AREA WITH NO
NURSE CALL
EQUIPMENT
02/10/2021
2C102
TOILET
C212
CORR
2C100
STOR
2C101
OFFICE
2A112
HAC
S2-3
STAIR 3
C203
CORR
2A101
ELEC
2B105
S LINEN
C205
CORR
2B106A
TOILET
2B131
EXAM
C208
NURSE STA - HAS
2B132
BREAK ROOM
2B133
EQUIP STOR
2B134
EQUIP STOR
2B135
SPD
C202
CORR
S2-1
STAIR 1
2B121A
TOILET
C206
CORR
2B118
EXAM
2B119
EXAM
2B119A
TOILET
2B117A
TOILET
2B117
EXAM
2B126
EQUIP STOR
2B125
STAFF
2B116
SPD
C209
C0RR
2B130
HAC
2B128
EXAM
2B127
GEN STOR
2B123A
TOILET
2B115
ELEC
2B114
TELE
2B106
EXAM
2B113
EXAM
2B112A
TOILET
2B107A
TOILET
2B107
EXAM
C207
C0RR
2B112
EXAM
2B111
EXAM
2B108
EXAM
2B108A
TOILET
2B109
EXAM
2B110
EXAM
2B110A
TOILET
C201
CORR
2A100A
HALLWAY
2B120
EXAM
2B124
EXAM
2A105B
XRAY ROOM
2A104
GI Recovery Room
2A119
ENDO
PROCEDURE
2A118
ENDO PROCEDURE
2A123
RECOVERY
2A114
RECOVERY
2A115
RECOVERY
2A117
SALLY PORT
2A113
MEDS
2A…