This is a pricing sheet for RFP 20-0141, a fencing project issued by the City of Detroit (DPSCD). The procurement covers comprehensive fencing services including removal and disposal of existing fencing in heights ranging from 2 feet to 12 feet, installation of new chain link fencing at 4, 6, 7, 8, and 10 feet heights, and associated gate and hardware installation. The scope of work includes helically wound 2-inch mesh chain link fabric with 9-gauge specifications, concrete footings at 42 inches deep with 12-inch diameter requirements, and 36-inch post penetration depths. Additional items include single swing gates and cantilevered gates in 6-foot and 8-foot heights, automatic gate openers with remote controls, pipe bollards with concrete footings, earth excavation and disposal, finish grading, and hourly rates for repairs, emergency gate malfunctions, power outage resets, and electrical connections.
The pricing sheet utilizes a tiered cost structure based on project size, with quantities measured in linear feet, each units, cubic yards, and square yards depending on the service line item. Bidders are required to submit unit costs for each CLIN (Contract Line Item Number) across multiple quantity brackets to allow the government to evaluate pricing efficiency at different project scales. The document does not specify contract term, renewal options, set-asides, incumbent information, funding sources, or award dates within the pricing sheet itself, as these details would typically be contained in accompanying solicitation documents or the RFP narrative.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Fencing Pricing Sheet 20-0141 Fencing RFP Pricing Sheet
CLIN DESCRIPTION QUANTITIES PAY UNIT COST
1 Remove and Dispose of Fencing 2’ in Height 25 L.F. or Less Linear Feet
2 26 – 50 Linear Feet
3 51 – 150 L.F.
4 151 and More L.F.
5 Remove and Dispose of Fencing 4’ in Height 25 L.F. or Less L.F.
6 26 – 50 L.F.
7 51 – 150 L.F.
8 151 and More L.F.
9 Remove and Dispose of Fencing 6’ in Height 25 L.F. or Less L.F.
10 26 – 50 L.F.
11 51 – 150 L.F.
12 151 and More L.F.
13 Remove and Dispose of Fencing 7’ in Height 25 L.F. or Less L.F.
14 25 – 51 L.F.
15 51 – 150 L.F.
16 151 and More L.F.
17 Remove and Dispose of Fencing 8’ in Height 25 L.F. or Less L.F.
18 26 – 50 L.F.
19 51 – 150 L.F.
20 150 and More L.F.
21 Remove and Dispose of Fencing 10’ in Height 25 L.F. or Less L.F.
22 26 – 50 L.F.
23 51 – 150 L.F.
24 151 and More L.F.
25 Remove and Dispose of Fencing 12’ in Height 25 L.F. or Less L.F.
26 26 – 50 L.F.
27 51 – 150 L.F.
28 151 and More L.F.
| Chain Link Fence, 4 Ft. Height: | |||
| 29 | Helically Wound 2-Inch Mesh, 0.192-Inch (9 Gauge) Chain Link Fabric Complete With All Line Posts, Corner Posts, Terminal Posts, Pull Posts, Top Rails, Bottom Rails, Brace Rail, Ties, And Incidental Hardware. All Posts Are To Be Installed With A 36” Penetration Into A 42” Deep Concrete Footing, 12” In Diameter. | 25 L.F. or Less | L.F. |
30 26 – 50 L.F.
31 51 – 150 L.F.
32 151 and More L.F.
| 4’ High Single Swing Gate 6’ Wide | |||
| 33 | Helically Wound 2-Inch Mesh, 0.192- | 3 or Less | Each |
| Inch (9 Gauge) Chain Link Fabric Complete With All Line Posts, Corner Posts, Terminal Posts, Pull Posts, Top Rails, Bottom Rails, Brace Rail, Ties, And Incidental Hardware. All Posts Are To Be Installed With A 36” Penetration Into A 42” Deep Concrete Footing, 12” In Diameter. | |||
| 34 | 4 or More | EA. | |
| Chain Link Fence – 6’ Height |
35 Helically Wound 2-Inch Mesh, 0.192-Inch (9 Gauge) Chain Link Fabric Complete With All Line Posts, Corner Posts, Terminal Posts, Pull Posts, Top Rails, Bottom Rails, Brace Rail, Ties, And Incidental Hardware. All Posts Are To Be Installed With A 36” Penetration Into A 42” Deep Concrete Footing, 12” In Dia.. 25 L.F. or Less Linear Feet
36 26 – 50 L.F.
37 51 – 150 L.F.
6’ High Single Swing Gate – 6’ Wide
| 38 | Helically Wound 2-Inch Mesh, 0.192-Inch (9 Gauge) Chain Link Fabric | 3 or Less | Each |
| Complete With All Line Posts, Corner Posts, Terminal Posts, Pull Posts, Top Rails, Bottom Rails, Brace Rail, Ties, And Incidental Hardware. Continued Next Page. All Posts Are To Be Installed With A 36” Penetration Into A 42” Deep Concrete Footing, 12” In Diameter. |
| 39 | 4 or More | ||
| Chain Link Fence, 7’ High | |||
| 40 | Helically Wound 2-Inch Mesh, 0.192-Inch (9 Gauge) Chain Link Fabric Complete With All Line Posts, Corner Posts, Terminal Posts, Pull Posts, Top Rails, Bottom Rails, Brace Rail, Ties, And Incidental Hardware. All Posts Are To Be Installed With A 36” Penetration Into A 42” Deep Concrete Footing, 12” In Diameter. | 25 L.F. or Less | L.F. |
41 26 – 50 L.F.
42 51 – 150 L.F.
43 151 and Up L.F.
7’ High Single Swing Gate – 6’ Wide
| 44 | Helically Wound 2-Inch Mesh, 0.192-Inch (9 Gauge) Chain Link Fabric Complete With All Line Posts, Corner Posts, Terminal | 3 or Less | EA. |
| Posts, Pull Posts, Top Rails, Bottom | |||
| 45 | Rails, Brace Rail, Ties, And Incidental Hardware. All Posts Are To Be Installed With A 36” Penetration Into A 42” Deep Concrete Footing, 12” In Diameter. | 4 OR More | EA. |
| Chain Link Fence, 8’ High | |||
| 46 | Helically Wound 2-Inch Mesh, 0.192-Inch (9 Gauge) Chain Link Fabric Complete With All Line Posts, Corner Posts, Terminal Posts, Pull Posts, Top Rails, Bottom Rails, Brace Rail, Ties, And Incidental Hardware. All Posts Are To Be Installed With A 36” Penetration Into A 42” Deep Concrete Footing, 12” In Diameter. | 25 L.F. or Less | L.F. |
47 26 – 50 L.F.
48 51 – 150 L.F.
49 151 and Up L.F.
8’ High Single Swing Gate – 6’ Wide
| 50 | Helically Wound 2-Inch Mesh, 0.192-Inch (9 Gauge) Chain Link Fabric Complete With All Line Posts, Corner Posts, Terminal Posts, Pull Posts, Top Rails, Bottom Rails, Brace Rail, Ties, And Incidental Hardware. | 3 or Less | EA. |
| All Posts Are To Be Installed With A 36” Penetration Into A 42” Deep Concrete Footing, 12” In Diameter. | |||
| 51 | 4 or More | EA. | |
| Chain Link Fence, 10’ High | |||
| 52 | Helically Wound 2-Inch Mesh, 0.192-Inch (9 Gauge) Chain Link Fabric Complete With All Line Posts, Corner Posts, Terminal Posts, Pull Posts, Top Rails, Bottom Rails, Brace Rail, Ties, And Incidental Hardware. All Posts Are To Be Installed With A 36” Penetration Into A 42” Deep Concrete Footing, 12” In Diameter. | 25 L.F. or Less | L.F. |
53 26 – 50 L.F.
54 51 – 150 L.F.
55 151 and Up L.F.
| 10’ High Single Swing Gate – 6’ Wide | |||
| 56 | Helically Wound 2-Inch Mesh, 0.192-Inch (9 Gauge) Chain Link Fabric Complete With All Line Posts, Corner Posts, Terminal Posts, Pull Posts, Top Rails, Bottom Rails, Brace Rail, Ties, And Incidental Hardware. All Posts Are To Be Installed With A 36” Penetration Into A 42” Deep Concrete Footing, 12” In Diameter. | 3 or Less | EA. |
| 57 | 4 or More | EA. | |
| Earth Excavation and Disposal Offsite | |||
| 58 | 10 or less | Cubic Yards |
59 11 to 20 CY
| 60 | 21 and over | CY | |
| Finish Grading | |||
| 61 | 1000 or less | Square Yards |
62 1001 or more Square Yards
| Automatic Gate Opener | |||
| 63 | Automatic Gate Opener, Install gate opener to support gate up to 75 feet and up to 1900 pounds With weather resistant steel, lockable enclosure, built in overload protection, gate speed of no less than 12" per second, automatic braking system, on concrete pad with post mounted standard with weatherproof chain, 24V AC power, with a minimum of 24 remote gate openers. All electrical services to connect to DPSCD supplied power at site. Concrete footings per all applicable standards. DPSCD to approve location. Chain and transfer mechanisms shall be approriately tensioned. | 3 or less | EA |
64 More than 3 EA
| Pipe Bollards | |||
| 12 " concrete filled pipe bollards with 42" concrete footings, | |||
| 65 | painted with exterior paint, color as directed. | less than 12 | EA |
66 12 or more EA
67 Hourly Rate for Repairs, Emergency Gate Malfunctions, Power outage resets, other service calls, labor only per hour
Cantelevered Gate for Chain Link Fence – 6’ Height
68 Helically Wound 2-Inch Mesh, 0.192-Inch (9 Gauge) Chain Link Fabric Complete With All Line Posts, Corner Posts, Terminal Posts, Latches, Pull Posts, Top Rails, Bottom Rails, Brace Rail(s), Rollers, Track(s), Ties, And Incidental Hardware. All Posts Are To Be Installed With A 36” Penetration Into A 42” Deep Concrete Footing, 12” In Dia.. 1 EA
69 3 to 5 EA
70 6 and up EA
Cantelevered Gate for Chain Link Fence – 8’ Height
71 Helically Wound 2-Inch Mesh, 0.192-Inch (9 Gauge) Chain Link Fabric Complete With All Line Posts, Corner Posts, Latches,Terminal Posts, Pull Posts, Top Rails, Bottom Rails, Brace Rail(s), Rollers, Track(s), Ties, And Incidental Hardware. All Posts Are To Be Installed With A 36” Penetration Into A 42” Deep Concrete Footing, 12” In Dia.. 1 EA
72 3 to 5 EA
73 6 and up EA
74 Hourly rate for electrical connection to on site power source, as per City of Detroit ordinances, and all applicable regulations and laws, labor only per hour
| Loop Detector | |||
| 75 | Loop detector and all connections to gate operator, all labor to install | 1 | EA |