2-W Maple Grove Rd and Fivepointville Rd Sanitary Sewer Repairs Project Drawings 4713.005.pdf
PDF 4 MB Posted
- Solicitation number
- US.262757
- Issued by
- Lancaster County, Pennsylvania
About this file
Summary of Project Drawings for West Maple Grove Road and Fivepointville Road Sanitary Sewer Repairs
This document comprises the project drawings for the West Maple Grove Road and Fivepointville Road Sanitary Sewer Repairs project (Contract No. 26-3, Entech Project No. 4713.005) prepared by Entech Engineering for the Northern Lancaster County Authority in Brecknock Township, Lancaster County, Pennsylvania. The project scope includes the replacement of approximately 360 linear feet of existing 8-inch PVC sanitary sewer piping with new SDR-26 PVC pipe across seven designated project areas, replacement of approximately 30 linear feet of 6-inch SDR-26 PVC sanitary sewer lateral, replacement of seven existing manhole composite riser rings, modification of an existing manhole drop connection to convert from external to internal configuration, and PennDOT roadway pavement restoration at multiple locations. The drawings package includes a location/topographical map, general project notes and legend, detailed plans for each of the seven project areas, construction details for sewer connections and manhole modifications, restoration details for both grass and paved areas, and erosion and sedimentation control details. Bids are due electronically via PennBid by 2:00 PM on Wednesday, December 30, 2026, with a mandatory pre-bid conference scheduled for Wednesday, December 2, 2026 at 10:00 AM at 983 Beam Road, Denver, PA 17517. Bidders who fail to attend the mandatory pre-bid conference will not have their bids accepted.
The project imposes multiple contractor responsibilities including compliance with Pennsylvania Act No. 287 regarding underground utility location, traffic control and detour management, shoring device provision and maintenance, use of rubber-tracked excavators or matting to protect road surfaces, maintenance of residential access and utility services throughout construction, temporary bypass pumping operations during construction, and adherence to all erosion and sedimentation control regulations and PennDOT permit conditions. Contractors must also verify existing sewer slopes, match existing surface elevations for manhole grade adjustments, provide adequate restoration of residential yards and garden areas, and notify PennDOT at minimum one week prior to construction start. The drawings indicate seven separate limits of disturbance, each encompassing 0.12 acres, with specific road opening dimensions and restoration requirements varying by project area and road type, including mill and overlay operations for state routes. All project documents are available at no cost through the PennBid Program.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BRECKNOCK
TOWNSHIP
LANCASTER
COUNTY
PROJECT AREA #2
PROJECT AREA #3
PROJECT AREA #1
PROJECT AREA #4
PROJECT AREA #5
PROJECT AREA #6
PROJECT AREA #7
CIVIL LEGEND
LIMIT OF DISTURBANCE
SL PROPOSED SANITARY LATERAL
PROPOSED SANITARY MAINSAN
TEXT PROPOSED TEXT
4713.005
A
B
2 3
C
D
1 2 3
4 5 6
PROJECT NO.
APPROVED BY:
SCALE:
CHECKED BY:
PREPARED BY:
A
B
D
AT
E R
EV
4 5
IS
SU
ED
F
O R
/R
EV
IS
ED
C
AP
PD
D
DRAWING NO.
Entech Engineering - Printed: Nov. 13, 2026 H:\0004713.005\04-CAD\SheetFiles\G-001.dwgLa st
E di te d by : e m ot te r
G-001
NO
RT
HE
RN
L
AN
CA
ST
ER
C
O
UN
TY
A
UT
HO
RI
TY
BR
EC
KN
O
C K
TO
W
N
SH
IP
, L
AN
C
AS
TE
R C
O U
N
TY
, P
EN
N
SY
LV
AN
IA
W M
AP
LE
G
RO
VE
R
OA
D
AN
D
FI
VE
PO
IN
TV
IL
LE
R
OA
D
SE
W
ER
R
EP
AI
RS
AGS
ARA
AS NOTED
/1
2/
A
IN
TE
R N
AL
Q
C
AG
S
/2 0/
B
C
LI
EN
T R
EV
IE
W
AG
S
/1 3/
C
BI
D D
IN
G
AG
S
00 2000' 4000' Scale:1 1" = 2000'
LOCATION / TOPOGRAPHICAL MAP
DR
AW
IN
G
IN
DE
X, G
EN
ER
AL
P
RO
JE
CT
N
O
TE
S, L
EG
EN
D
AN
D
DR
AW
IN
G C
O
NV
EN
TI
O
NS
G
EN
ER
AL
SECTION INDICATOR
DETAIL INDICATOR
ELEVATION INDICATOR
DRAWING CONVENTIONS
?-201
A ?-301
A ?-301
?-501
SCALE:1 1" = 1'-0"
DRAWING TITLE
DRAWING NUMBER
SECTION LETTER
DRAWING NUMBER
ELEVATION LETTER
IDENTIFICATION NUMBER/LETTER
DRAWING TITLE
SHEET KEYNOTE SYMBOL
DRAWING NUMBER
DETAIL NUMBER
TEXT
INDICATES EXIST
CONDITIONS/FEATURES
INDICATES NEW
WORK/FEATURES
A. PROJECT DRAWINGS MUST BE WORKED IN CONJUNCTION WITH THE PROJECT
MANUAL AND SPECIFICATIONS.
B. ALL DIMENSIONS, ELEVATIONS, AND EXISTING CONDITIONS MUST BE CHECKED
AND VERIFIED AT THE PROJECT SITE PRIOR TO CONSTRUCTION.
C. ALL UNDERGROUND UTILITIES SHALL BE LOCATED BY THE CONTRACTOR PRIOR
TO ANY EARTH MOVING ACTIVITIES PURSUANT TO PA ACT NO. 287, AS AMENDED
BY ACT 50 OF 2017. UNDERGROUND UTILITIES MUST BE VERIFIED BY
CONTACTING THE “ONE CALL SYSTEM” AT 1-800-242-1776 OR ONLINE AT
PAONECALL.ORG.
D. CONTRACTOR IS RESPONSIBLE FOR TRAFFIC CONTROL AND DETOURS AS
DEFINED IN THE PROJECT MANUAL.
E. CONTRACTOR SHALL USE, MAINTAIN, AND ALWAYS PROVIDE ADEQUATE
SHORING DEVICES ON SITE. CONTRACTOR SHALL CONFORM TO ALL LOCAL,
STATE, AND FEDERAL REGULATIONS.
F. CONTRACTOR SHALL USE RUBBER TRACKED EXCAVATOR OR PROVIDE 1” THICK
MINIMUM MATTING TO PROTECT PAVED LOCAL MUNICIPAL, STATE, AND PRIVATE
ROAD SURFACES DURING TRENCHING, EXCAVATION, AND GENERAL
CONSTRUCTION OPERATIONS.
G. CONTRACTOR IS RESPONSIBLE TO MAINTAIN ACCESS TO ALL RESIDENCES
THROUGHOUT CONSTRUCTION.
H. CONTRACTOR IS RESPONSIBLE FOR RESTORATION OF RESIDENTIAL YARD AND
GARDEN AREAS.
I. CONTRACTOR IS RESPONSIBLE TO MAINTAIN UTILITY SERVICES TO ALL
RESIDENTS THROUGHOUT CONSTRUCTION.
J. CONTRACTOR SHALL ABIDE BY ALL ISSUED PERMIT CONDITIONS INCLUDING BUT
NOT LIMITED TO EROSION AND SEDIMENTATION CONTROL (CHAPTER 102) AND
THE GENERAL PERMITS (CHAPTER 105).
K. FINAL RESTORATION SHALL BE IN ACCORDANCE WITH THE FINAL ISSUED
PENNDOT HIGHWAY OCCUPANCY PERMITS.
L. CONTRACTOR SHALL NOTIFY PENNDOT AT MINIMUM OF ONE (1) WEEK PRIOR TO
START OF CONSTRUCTION.
M. THE CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY BYPASS PUMPING
OPERATIONS DURING CONSTRUCTION.
N. CONTRACTOR TO VERIFY EXISTING SLOPES FOR ALL SANITARY SEWER REPAIRS
TO ENSURE THAT SLOPE IS MAINTAINED.
O. CONTRACTOR TO MATCH EXISTING SURFACE ELEVATIONS FOR ALL SANITARY
SEWER MANHOLE GRADE ADJUSTMENTS.
GENERAL PROJECT NOTES
REFERENCE: USGS 7.5 MINUTE SERIES (TOPOGRAPHIC MAPS) MORGANTOWN AND TERRE HILL, PENNSYLVANIA
1-800-242-1776
(TOLL FREE)
"Pa. Law requires advance notification"
PA ONE CALL FOR DESIGN
COORDINATE PA: 16401187
SERIAL NUMBERS:
20262873043 (FINAL DESIGN)
1-800-242-1776
PE
NN
SY
LV
ANIA ONE CALL SYSTEM
, INC
STOP-CALL BEFORE YOU D
IG
SCALE:2 NONE
VICINITY MAP
DESIGN PA ONE CALL
UTILITY RESPONSE ADDRESS CONTACT INFORMATION PHONE CONTACT PERSON
BRECKNOCK TOWNSHIP LANCASTER COUNTY 1026 DRY TAVERN RD
DENVER, PA. 17517 cmartin@brecknocktownship.us 717-445-5933 CAROL MARTIN
METROPOLITAN EDISON CO/FIRSTENERGY 341 WHITE POND DR
AKRON, OH. 44320 madams@firstenergycorp.com 330-252-4013 MELLYSSA ADAMS
NORTHERN LANCASTER COUNTY AUTHORITY 983 BEAM ROAD
DENVER, PA. 17517 mross@nlcaonline.com 717-445-7553 MATT ROSS
PPL ELECTRIC UTILITIES CORPORATION 4810 LYCOMING MALL
MONTOURSVILLE, PA. 17754 pdseitzer@pplweb.com 570-368-5394 PAMELA SEITZER
PENCOR SERVICES/BLUE RIDGE COMMUNICATION 462 DELAWARE AVE
PALMERTON, PA. 18071-1909 jbuccieri@brctv.com 610-826-9504 JOE BUCCIERI
SERVICE ELECTRIC CABLEVISION INC PO BOX 8
BIRDSBORO, PA. 19508 mike.spayd@secv.com 610-582-5317 MIKE SPAYD
FRONTIER COMMUNICATIONS OF PA INC 300E LAIRD ST
WILKES BARRE, PA. 18702 michael.navich@ftr.com 570-208-3375 MICHAEL NAVICH
DRAWING INDEX
DWG. NO. DRAWING DESCRIPTION/TITLE
GENERAL
G-001 DRAWING INDEX, GENERAL PROJECT NOTES, LEGEND AND DRAWING
CONVENTIONS
G-101 INDEX PLAN
CIVIL
C-101
FIVEPOINTVILLE ROAD SANITARY SEWER REPAIR PLANS
(PROJECT AREAS #1 AND #2)
C-102
W MAPLE GROVE ROAD SANITARY SEWER REPAIR PLAN
(PROJECT AREA #3)
C-103
READING ROAD SANITARY SEWER REPAIR PLANS
(PROJECT AREAS #4 AND #5)
C-104
READING ROAD SANITARY SEWER REPAIR PLANS
(PROJECT AREAS #6 AND # 7)
C-501 CONSTRUCTION DETAILS
C-701 RESTORATION DETAILS
EROSION AND SEDIMENTATION
ES-501 CONTROL DETAILS
NOVEMBER 13, 2026
NORTHERN LANCASTER COUNTY AUTHORITY
W MAPLE GROVE ROAD AND FIVEPOINTVILLE ROAD
SEWER REPAIR PROJECT - CONTRACT NO. 26-3
OFFICE ADDRESS:
983 BEAM ROAD
DENVER, PA. 17517
ISSUED FOR BIDDING
PROJECT SITE
PROJECT SITE
PROJECT SITE
REFERENCE DRAWINGS
1. EXISTING COLLECTION SYSTEM DRAWINGS REFERENCE EBERT
ENGINEERING, INC. "GENERAL PLANS OF SANITARY SEWERS FOR THE
NORTHERN LANCASTER COUNTY AUTHORITY" JOB #063-001 DATED JULY
6, 2012.
G
EN
ER
AL
IN
D
EX
P
LA
N
"PROJECT AREA #1"
DRAWING C-101
PLAN 1
"PROJECT AREA #2"
DRAWING C-101
PLAN 2
"PROJECT AREA #3"
DRAWING C-102
PLAN 1
SCALE:1 1" = 500'
INDEX PLAN
00 500' 1000'
4713.005
A
B
2 3
C
D
1 2 3
4 5 6
PROJECT NO.
APPROVED BY:
SCALE:
CHECKED BY:
PREPARED BY:
A
B
D
AT
E R
EV
4 5
IS
SU
ED
F
O R
/R
EV
IS
ED
C
AP
PD
D
DRAWING NO.
Entech Engineering - Printed: Nov. 13, 2026 H:\0004713.005\04-CAD\SheetFiles\G-101.dwgLa st
E di te d by : m hi es te r
G-101
NO
RT
HE
RN
L
AN
CA
ST
ER
C
O
UN
TY
A
UT
HO
RI
TY
BR
EC
KN
O
C K
TO
W
N
SH
IP
, L
AN
C
AS
TE
R C
O U
N
TY
, P
EN
N
SY
LV
AN
IA
W M
AP
LE
G
RO
VE
R
OA
D
AN
D
FI
VE
PO
IN
TV
IL
LE
R
OA
D
SE
W
ER
R
EP
AI
RS
AGS
ARA
AS NOTED
/1
2/
A
IN
TE
R N
AL
Q
C
AG
S
/2 0/
B
C
LI
EN
T R
EV
IE
W
AG
S
/1 3/
C
BI
D D
IN
G
AG
S
"PROJECT AREA #4"
DRAWING C-103
PLAN 1
"PROJECT AREA #5"
DRAWING C-103
PLAN 2
"PROJECT AREA #7"
DRAWING C-104
PLAN 2
"PROJECT AREA #6"
DRAWING C-104
PLAN 1
4713.005
A
B
2 3
C
D
1 2 3
4 5 6
PROJECT NO.
APPROVED BY:
SCALE:
CHECKED BY:
PREPARED BY:
A
B
D
AT
E R
EV
4 5
IS
SU
ED
F
O R
/R
EV
IS
ED
C
AP
PD
D
DRAWING NO.
Entech Engineering - Printed: Nov. 13, 2026 H:\0004713.005\04-CAD\SheetFiles\C-101.dwgLa st
E di te d by : A
A tti ck
C-101
NO
RT
HE
RN
L
AN
CA
ST
ER
C
O
UN
TY
A
UT
HO
RI
TY
BR
EC
KN
O
C K
TO
W
N
SH
IP
, L
AN
C
AS
TE
R C
O U
N
TY
, P
EN
N
SY
LV
AN
IA
W M
AP
LE
G
RO
VE
R
OA
D
AN
D
FI
VE
PO
IN
TV
IL
LE
R
OA
D
SE
W
ER
R
EP
AI
RS
AGS
ARA
AS NOTED
/1
2/
A
IN
TE
R N
AL
Q
C
AG
S
/2 0/
B
C
LI
EN
T R
EV
IE
W
AG
S
/1 3/
C
BI
D D
IN
G
AG
S
GENERAL PROJECT NOTES
1. REFER TO DRAWING G-001 FOR DRAWING INDEX, GENERAL PROJECT
NOTES, LEGEND AND DRAWING CONVENTIONS.
2. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR FOR THE
REMOVAL AND DISPOSAL OF THE EXISTING SANITARY SEWER MAIN AND
SANITARY MANHOLES THAT ARE REMOVED FROM SERVICE.
C
IV
IL
FI
VE
PO
IN
TV
IL
LE
R O
AD
S
AN
IT
AR
Y
SE
W
ER
R
EP
AI
R P
LA
N
S (P
R O
JE
C
T
AR
EA
S
#1 A
N D
2)
PROPOSED 8'x8' ROAD OPENING
MANHOLE RISER RINGS TO BE REMOVED
AND REPLACED W/ COMPOSITE RISER
SCALE:1 1" = 30'
SANITARY SEWER REPAIR PLAN
FIVEPOINTVILLE ROAD
PROJECT AREA #1
00 30' 60'
SCALE:2 1" = 30'
SANITARY SEWER REPAIR PLAN
FIVEPOINTVILLE ROAD
PROJECT AREA #2
00 30' 60'
PROPOSED 8'x8' ROAD OPENING
MANHOLE RISER RINGS TO BE REMOVED
AND REPLACED W/ COMPOSITE RISER
FILTER BAG INLET
PROTECTION - TYPE M
ES-501
E&S CONTROL NOTES
1. CONTRACTOR IS RESPONSIBLE TO COMPLY WITH CHAPTER 102
EROSION CONTROL RULES AND REGULATIONS AND FOLLOW GUIDANCE
IN THE PADEP EROSION AND SEDIMENT POLLUTION CONTROL PROGRAM
MANUAL.
2. CONTRACTOR TO LIMIT THE DISTURBED AREA TO THE MINIMUM AMOUNT
POSSIBLE FOR THE INSTALLATION.
3. THE INSTALLATION OF ALL REQUIRED EROSION AND SEDIMENT
CONTROL DEVICES SHALL OCCUR PRIOR TO EARTHMOVING ACTIVITIES.
4. E&S CONTROLS ARE TO REMAIN IN PLACE UNTIL ALL AREAS ARE
PROPERLY STABILIZED WITH A PERMANENT GROUND COVER.
5. PROVIDE TEMPORARY AND PERMANENT SEEDING PER THE
SPECIFICATIONS OF THE PADEP EROSION AND SEDIMENT POLLUTION
CONTROL PROGRAM MANUAL.
6. CONTRACTOR SHALL PREVENT THE TRACKING OF SEDIMENT ONTO
ADJOINING PAVED AREAS AND PUBLIC STREETS BY CONSTRUCTION
VEHICLES. SEDIMENT SHALL BE CLEANED FROM PAVED AREAS DAILY.
7. UNTIL THE SITE IS STABILIZED, ALL EROSION AND SEDIMENT BMPS
SHALL BE MAINTAINED PROPERLY BY THE CONTRACTOR. MAINTENANCE
SHALL INCLUDE INSPECTIONS OF ALL EROSION AND SEDIMENT BMPS
AFTER EACH RUNOFF EVENT AND ON A WEEKLY BASIS. ALL
PREVENTATIVE AND REMEDIAL MAINTENANCE WORK, INCLUDING CLEAN
OUT, REPAIR, REPLACEMENT, RE-GRADING, RESEEDING, RE-MULCHING
AND RE-NETTING MUST BE PERFORMED IMMEDIATELY. IF THE E&S BMPS
FAIL TO PERFORM AS EXPECTED, REPLACEMENT BMPS, OR
MODIFICATIONS OF THOSE INSTALLED WILL BE REQUIRED.
FILTER BAG INLET
PROTECTION - TYPE M
ES-501
SR 1046
SEGMENT 0050
OFFSET 1717
SR 0897
SEGMENT 0350
OFFSET 2967
SR 0897
SEGMENT 0360
OFFSET 0000
SR 1046
SEGMENT 0060
OFFSET 0000
SR 1046
SEGMENT 0050
OFFSET 3309
C-501
C-501
TOTAL LOD: 0.12 ACRES
TOTAL LOD: 0.12 ACRES
C-701
C-701
SAN
2200 2300 2400 2500 2600 2700 2800
0000 0100
4713.005
A
B
2 3
C
D
1 2 3
4 5 6
PROJECT NO.
APPROVED BY:
SCALE:
CHECKED BY:
PREPARED BY:
A
B
D
AT
E R
EV
4 5
IS
SU
ED
F
O R
/R
EV
IS
ED
C
AP
PD
D
DRAWING NO.
Entech Engineering - Printed: Nov. 13, 2026 H:\0004713.005\04-CAD\SheetFiles\C-102.dwgLa st
E di te d by : A
A tti ck
C-102
NO
RT
HE
RN
L
AN
CA
ST
ER
C
O
UN
TY
A
UT
HO
RI
TY
BR
EC
KN
O
C K
TO
W
N
SH
IP
, L
AN
C
AS
TE
R C
O U
N
TY
, P
EN
N
SY
LV
AN
IA
W M
AP
LE
G
RO
VE
R
OA
D
AN
D
FI
VE
PO
IN
TV
IL
LE
R
OA
D
SE
W
ER
R
EP
AI
RS
AGS
ARA
AS NOTED
/1
2/
A
IN
TE
R N
AL
Q
C
AG
S
/2 0/
B
C
LI
EN
T R
EV
IE
W
AG
S
/1 3/
C
BI
D D
IN
G
AG
S
GENERAL PROJECT NOTES
1. REFER TO DRAWING G-001 FOR DRAWING INDEX, GENERAL PROJECT
NOTES, LEGEND AND DRAWING CONVENTIONS.
2. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR FOR THE
REMOVAL AND DISPOSAL OF THE EXISTING SANITARY SEWER MAIN AND
SANITARY MANHOLES THAT ARE REMOVED FROM SERVICE.
C
IV
IL
W
M
AP
LE
G
R O
VE
R
O
AD
S
AN
IT
AR
Y
SE
W
ER
R
EP
AI
R
P
LA
N (P
R O
JE
C
T
AR
EA
3)
SCALE:1 1" = 30'
SANITARY SEWER REPAIR PLAN
W MAPLE GROVE ROAD
PROJECT AREA #3
00 30' 60'
CUT EXISTING 8" PVC SANITARY
SEWER AND REPLACE WITH 40 LF OF
NEW SDR-26 PVC SANITARY SEWER
PROPOSED 5'x40'
ROAD OPENING
PROPOSED 5'x50'
ROAD OPENING
PROPOSED 5'x25'
ROAD OPENING
CUT EXISTING 8" PVC SANITARY
SEWER AND REPLACE WITH 20 LF OF
NEW SDR-26 PVC SANITARY SEWER
PROPOSED 6" SDR-26 PVC LATERAL (30 LF)
MANHOLE RISER RINGS TO
BE REMOVED AND REPLACED
W/ COMPOSITE RISER
MANHOLE RISER RINGS TO BE REMOVED
AND REPLACED W/ COMPOSITE RISER
CUT EXISTING 8" PVC SANITARY
SEWER AND REPLACE WITH 25 LF OF
NEW SDR-26 PVC SANITARY SEWER
FILTER BAG INLET
PROTECTION - TYPE M
ES-501
E&S CONTROL NOTES
1. CONTRACTOR IS RESPONSIBLE TO COMPLY WITH CHAPTER 102
EROSION CONTROL RULES AND REGULATIONS AND FOLLOW GUIDANCE
IN THE PADEP EROSION AND SEDIMENT POLLUTION CONTROL PROGRAM
MANUAL.
2. CONTRACTOR TO LIMIT THE DISTURBED AREA TO THE MINIMUM AMOUNT
POSSIBLE FOR THE INSTALLATION.
3. THE INSTALLATION OF ALL REQUIRED EROSION AND SEDIMENT
CONTROL DEVICES SHALL OCCUR PRIOR TO EARTHMOVING ACTIVITIES.
4. E&S CONTROLS ARE TO REMAIN IN PLACE UNTIL ALL AREAS ARE
PROPERLY STABILIZED WITH A PERMANENT GROUND COVER.
5. PROVIDE TEMPORARY AND PERMANENT SEEDING PER THE
SPECIFICATIONS OF THE PADEP EROSION AND SEDIMENT POLLUTION
CONTROL PROGRAM MANUAL.
6. CONTRACTOR SHALL PREVENT THE TRACKING OF SEDIMENT ONTO
ADJOINING PAVED AREAS AND PUBLIC STREETS BY CONSTRUCTION
VEHICLES. SEDIMENT SHALL BE CLEANED FROM PAVED AREAS DAILY.
7. UNTIL THE SITE IS STABILIZED, ALL EROSION AND SEDIMENT BMPS
SHALL BE MAINTAINED PROPERLY BY THE CONTRACTOR. MAINTENANCE
SHALL INCLUDE INSPECTIONS OF ALL EROSION AND SEDIMENT BMPS
AFTER EACH RUNOFF EVENT AND ON A WEEKLY BASIS. ALL
PREVENTATIVE AND REMEDIAL MAINTENANCE WORK, INCLUDING CLEAN
OUT, REPAIR, REPLACEMENT, RE-GRADING, RESEEDING, RE-MULCHING
AND RE-NETTING MUST BE PERFORMED IMMEDIATELY. IF THE E&S BMPS
FAIL TO PERFORM AS EXPECTED, REPLACEMENT BMPS, OR
MODIFICATIONS OF THOSE INSTALLED WILL BE REQUIRED.
FILTER BAG INLET
PROTECTION - TYPE C
ES-501
SR 1046
SEGMENT 0100
OFFSET 2828
SR 1046
SEGMENT 0110
OFFSET 0000
C-501
C-501
C-501
C-501
C-501SR 1046
SEGMENT 0100
OFFSET 2259
C-701
C-501
C-701
C-501
C-501
TOTAL LOD: 0.12 ACRES
SHEET KEYNOTES
1. EXISTING LATERAL TO BE RECONNECTED TO NEW SANITARY SEWER
MAIN.
2200 2300
© 2026 Microsoft Corporation © Maxar ©CNES (2026) Distribution Airbus DS © Mapbox
SAN SAN
SAN
18001900200021002200230024002500
00000100
4713.005
A
B
2 3
C
D
1 2 3
4 5 6
PROJECT NO.
APPROVED BY:
SCALE:
CHECKED BY:
PREPARED BY:
A
B
D
AT
E R
EV
4 5
IS
SU
ED
F
O R
/R
EV
IS
ED
C
AP
PD
D
DRAWING NO.
Entech Engineering - Printed: Nov. 13, 2026 H:\0004713.005\04-CAD\SheetFiles\C-103.dwgLa st
E di te d by : A
A tti ck
C-103
NO
RT
HE
RN
L
AN
CA
ST
ER
C
O
UN
TY
A
UT
HO
RI
TY
BR
EC
KN
O
C K
TO
W
N
SH
IP
, L
AN
C
AS
TE
R C
O U
N
TY
, P
EN
N
SY
LV
AN
IA
W M
AP
LE
G
RO
VE
R
OA
D
AN
D
FI
VE
PO
IN
TV
IL
LE
R
OA
D
SE
W
ER
R
EP
AI
RS
AGS
ARA
AS NOTED
/1
2/
A
IN
TE
R N
AL
Q
C
AG
S
/2 0/
B
C
LI
EN
T R
EV
IE
W
AG
S
/1 3/
C
BI
D D
IN
G
AG
S
GENERAL PROJECT NOTES
1. REFER TO DRAWING G-001 FOR DRAWING INDEX, GENERAL PROJECT
NOTES, LEGEND AND DRAWING CONVENTIONS.
2. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR FOR THE
REMOVAL AND DISPOSAL OF THE EXISTING SANITARY SEWER MAIN AND
SANITARY MANHOLES THAT ARE REMOVED FROM SERVICE.
3. CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE SLOPE OF EXISTING
SEWER PRIOR TO COMPLETING SPOT REPAIRS.
C
IV
IL
R
EA
D
IN
G
R O
AD
S
AN
IT
AR
Y
SE
W
ER
R
EP
AI
R P
LA
N
S (P
R O
JE
C
T
AR
EA
AN
D
5)
SCALE:1 1" = 30'
SANITARY SEWER REPAIR PLAN
READING ROAD (SR 0625 SEG 0160)
PROJECT AREA #4
00 30' 60'
PROPOSED 10'x10' ROAD OPENING MANHOLE RISER RINGS TO BE REMOVED
AND REPLACED W/ COMPOSITE RISER,
REPLACE EXTERIOR MANHOLE DROP
WITH INTERIOR DROP. EXISTING EXTERNAL
DROP MANHOLE TO BE PLUGGED AND
FILLED WITH CONCRETE.
SCALE:2 1" = 30'
SANITARY SEWER REPAIR PLAN
READING ROAD (SR 0625 SEG 0150)
PROJECT AREA #5
00 30' 60'
CUT EXISTING 8" PVC SANITARY
SEWER AND REPLACE WITH 45 LF OF
NEW SDR-26 PVC SANITARY SEWER
CUT EXISTING 8" PVC SANITARY
SEWER AND REPLACE WITH 95 LF OF
NEW SDR-26 PVC SANITARY SEWER
PROPOSED 12'x30' ROAD OPENING
(MILL, BASE PAVE AND REPAIR, AND OVERLAY)
PROPOSED 10'x95' ROAD OPENING
PROPOSED 12'x12' ROAD OPENING
(MILL, BASE PAVE AND REPAIR, AND OVERLAY)
PROPOSED 5'x45' ROAD OPENING
FILTER BAG INLET
PROTECTION - TYPE M
ES-501
E&S CONTROL NOTES
1. CONTRACTOR IS RESPONSIBLE TO COMPLY WITH CHAPTER 102
EROSION CONTROL RULES AND REGULATIONS AND FOLLOW GUIDANCE
IN THE PADEP EROSION AND SEDIMENT POLLUTION CONTROL PROGRAM
MANUAL.
2. CONTRACTOR TO LIMIT THE DISTURBED AREA TO THE MINIMUM AMOUNT
POSSIBLE FOR THE INSTALLATION.
3. THE INSTALLATION OF ALL REQUIRED EROSION AND SEDIMENT
CONTROL DEVICES SHALL OCCUR PRIOR TO EARTHMOVING ACTIVITIES.
4. E&S CONTROLS ARE TO REMAIN IN PLACE UNTIL ALL AREAS ARE
PROPERLY STABILIZED WITH A PERMANENT GROUND COVER.
5. PROVIDE TEMPORARY AND PERMANENT SEEDING PER THE
SPECIFICATIONS OF THE PADEP EROSION AND SEDIMENT POLLUTION
CONTROL PROGRAM MANUAL.
6. CONTRACTOR SHALL PREVENT THE TRACKING OF SEDIMENT ONTO
ADJOINING PAVED AREAS AND PUBLIC STREETS BY CONSTRUCTION
VEHICLES. SEDIMENT SHALL BE CLEANED FROM PAVED AREAS DAILY.
7. UNTIL THE SITE IS STABILIZED, ALL EROSION AND SEDIMENT BMPS
SHALL BE MAINTAINED PROPERLY BY THE CONTRACTOR. MAINTENANCE
SHALL INCLUDE INSPECTIONS OF ALL EROSION AND SEDIMENT BMPS
AFTER EACH RUNOFF EVENT AND ON A WEEKLY BASIS. ALL
PREVENTATIVE AND REMEDIAL MAINTENANCE WORK, INCLUDING CLEAN
OUT, REPAIR, REPLACEMENT, RE-GRADING, RESEEDING, RE-MULCHING
AND RE-NETTING MUST BE PERFORMED IMMEDIATELY. IF THE E&S BMPS
FAIL TO PERFORM AS EXPECTED, REPLACEMENT BMPS, OR
MODIFICATIONS OF THOSE INSTALLED WILL BE REQUIRED.
C-501
C-501 SHEET KEYNOTES
1. CONTRACTOR TO REMOVE AND REPLACE EXISTING GUIDE RAIL TO
FACILITATE INSTALLATION OF NEW RISER RINGS FOR MANHOLE. REFER
TO PENNDOT RC-51M FOR DETAILS OF GUARDRAIL INSTALLATION.
2. EXISTING LATERAL TO BE RECONNECTED TO NEW SANITARY SEWER
MAIN.
C-701
C-701
SR 0625
SEGMENT 0150
OFFSET 2564
SR 0625
SEGMENT 0160
OFFSET 0000
SR 0625
SEGMENT 0150
OFFSET 2141
FILTER BAG INLET
PROTECTION - TYPE M
ES-501
C-701
C-501
C-701
C-501RECONNECT EXISTING 6" SDR-26
SANITARY SEWER LATERAL
C-501
PROPOSED 10'x10' ROAD OPENING MANHOLE RISER RINGS TO BE REMOVED
AND REPLACED W/ COMPOSITE RISER
TOTAL LOD: 0.12 ACRES
TOTAL LOD: 0.12 ACRES
REFER TO SYSTEM DRAWINGS
C-501
C-701
C-701
SAN
010002000300040005000600
SAN SAN
0600070008000900100011001200
SL
SL
4713.005
A
B
2 3
C
D
1 2 3
4 5 6
PROJECT NO.
APPROVED BY:
SCALE:
CHECKED BY:
PREPARED BY:
A
B
D
AT
E R
EV
4 5
IS
SU
ED
F
O R
/R
EV
IS
ED
C
AP
PD
D
DRAWING NO.
Entech Engineering - Printed: Nov. 13, 2026 H:\0004713.005\04-CAD\SheetFiles\C-104.dwgLa st
E di te d by : A
A tti ck
C-104
NO
RT
HE
RN
L
AN
CA
ST
ER
C
O
UN
TY
A
UT
HO
RI
TY
BR
EC
KN
O
C K
TO
W
N
SH
IP
, L
AN
C
AS
TE
R C
O U
N
TY
, P
EN
N
SY
LV
AN
IA
W M
AP
LE
G
RO
VE
R
OA
D
AN
D
FI
VE
PO
IN
TV
IL
LE
R
OA
D
SE
W
ER
R
EP
AI
RS
AGS
ARA
AS NOTED
/1
2/
A
IN
TE
R N
AL
Q
C
AG
S
/2 0/
B
C
LI
EN
T R
EV
IE
W
AG
S
/1 3/
C
BI
D D
IN
G
AG
S
GENERAL PROJECT NOTES
1. REFER TO DRAWING G-001 FOR DRAWING INDEX, GENERAL PROJECT
NOTES, LEGEND AND DRAWING CONVENTIONS.
2. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR FOR THE
REMOVAL AND DISPOSAL OF THE EXISTING SANITARY SEWER MAIN AND
SANITARY MANHOLES THAT ARE REMOVED FROM SERVICE.
C
IV
IL
R
EA
D
IN
G
R O
AD
S
AN
IT
AR
Y
SE
W
ER
R
EP
AI
R P
LA
N
S (P
R O
JE
C
T
AR
EA
S
#6 A
N D
7)
SCALE:1 1" = 30'
SANITARY SEWER REPAIR PLAN
READING ROAD (SR 0625 SEG 0150)
PROJECT AREA #6
00 30' 60'
CUT EXISTING 8" PVC SANITARY
SEWER AND REPLACE WITH 50 LF OF
NEW SDR-26 PVC SANITARY SEWER
PROPOSED 5'x50' ROAD OPENING PROPOSED 20'x80' ROAD OPENING (MILL, BASE PAVE AND REPAIR, AND OVERLAY) PROPOSED 10'x20' ROAD OPENING
(MILL, BASE PAVE AND REPAIR, AND OVERLAY)
SCALE:2 1" = 30'
SANITARY SEWER REPAIR PLAN
READING ROAD (SR 0625 SEG 0140)
PROJECT AREA #7
00 30' 60'
CUT EXISTING 8" PVC SANITARY
SEWER AND REPLACE WITH 40 LF
OF NEW SDR-26 PVC SANITARY SEWER
CUT EXISTING 8" PVC SANITARY
SEWER AND REPLACE WITH 40 LF
OF NEW SDR-26 PVC SANITARY SEWER
PROPOSED 10'x10' ROAD OPENING
MANHOLE RISER RINGS TO BE REMOVED
AND REPLACED W/ COMPOSITE RISER
PROPOSED 5'x40' ROAD OPENING
PROPOSED 5'x40' ROAD OPENING
FILTER BAG INLET
PROTECTION - TYPE M
FILTER BAG INLET
PROTECTION - TYPE M
FILTER BAG INLET
PROTECTION - TYPE M
ES-501
ES-501
ES-501
E&S CONTROL NOTES
1. CONTRACTOR IS RESPONSIBLE TO COMPLY WITH CHAPTER 102
EROSION CONTROL RULES AND REGULATIONS AND FOLLOW GUIDANCE
IN THE PADEP EROSION AND SEDIMENT POLLUTION CONTROL PROGRAM
MANUAL.
2. CONTRACTOR TO LIMIT THE DISTURBED AREA TO THE MINIMUM AMOUNT
POSSIBLE FOR THE INSTALLATION.
3. THE INSTALLATION OF ALL REQUIRED EROSION AND SEDIMENT
CONTROL DEVICES SHALL OCCUR PRIOR TO EARTHMOVING ACTIVITIES.
4. E&S CONTROLS ARE TO REMAIN IN PLACE UNTIL ALL AREAS ARE
PROPERLY STABILIZED WITH A PERMANENT GROUND COVER.
5. PROVIDE TEMPORARY AND PERMANENT SEEDING PER THE
SPECIFICATIONS OF THE PADEP EROSION AND SEDIMENT POLLUTION
CONTROL PROGRAM MANUAL.
6. CONTRACTOR SHALL PREVENT THE TRACKING OF SEDIMENT ONTO
ADJOINING PAVED AREAS AND PUBLIC STREETS BY CONSTRUCTION
VEHICLES. SEDIMENT SHALL BE CLEANED FROM PAVED AREAS DAILY.
7. UNTIL THE SITE IS STABILIZED, ALL EROSION AND SEDIMENT BMPS
SHALL BE MAINTAINED PROPERLY BY THE CONTRACTOR. MAINTENANCE
SHALL INCLUDE INSPECTIONS OF ALL EROSION AND SEDIMENT BMPS
AFTER EACH RUNOFF EVENT AND ON A WEEKLY BASIS. ALL
PREVENTATIVE AND REMEDIAL MAINTENANCE WORK, INCLUDING CLEAN
OUT, REPAIR, REPLACEMENT, RE-GRADING, RESEEDING, RE-MULCHING
AND RE-NETTING MUST BE PERFORMED IMMEDIATELY. IF THE E&S BMPS
FAIL TO PERFORM AS EXPECTED, REPLACEMENT BMPS, OR
MODIFICATIONS OF THOSE INSTALLED WILL BE REQUIRED.
C-501
C-501
C-701
C-701
C-701
C-501
C-701
C-5012
C-501
C-701
C-501
RECONNECT EXISTING 6" SDR-26
SANITARY SEWER LATERAL
RECONNECT EXISTING 6" SDR-26
SANITARY SEWER LATERAL
RECONNECT EXISTING 6" SDR-26
SANITARY SEWER LATERAL
RECONNECT EXISTING 6" SDR-26
SANITARY SEWER LATERAL
C-501
C-501
C-501
C-501
PROPOSED 12'x6' ROAD OPENING
(MILL, BASE PAVE AND REPAIR, AND OVERLAY)
C-701
TOTAL LOD: 0.12 ACRES
TOTAL LOD: 0.12 ACRES
PROPOSED 10'x10' ROAD OPENING
(MILL, BASE PAVE AND REPAIR, AND OVERLAY)
C-701
SHEET KEYNOTES
1. EXISTING LATERAL TO BE RECONNECTED TO NEW SANITARY SEWER
MAIN.
4713.005
A
B
2 3
C
D
1 2 3
4 5 6
PROJECT NO.
APPROVED BY:
SCALE:
CHECKED BY:
PREPARED BY:
A
B
D
AT
E R
EV
4 5
IS
SU
ED
F
O R
/R
EV
IS
ED
C
AP
PD
D
DRAWING NO.
Entech Engineering - Printed: Nov. 13, 2026 H:\0004713.005\04-CAD\SheetFiles\C-501.dwgLa st
E di te d by : A
A tti ck
C-501
NO
RT
HE
RN
L
AN
CA
ST
ER
C
O
UN
TY
A
UT
HO
RI
TY
BR
EC
KN
O
C K
TO
W
N
SH
IP
, L
AN
C
AS
TE
R C
O U
N
TY
, P
EN
N
SY
LV
AN
IA
W M
AP
LE
G
RO
VE
R
OA
D
AN
D
FI
VE
PO
IN
TV
IL
LE
R
OA
D
SE
W
ER
R
EP
AI
RS
AGS
ARA
AS NOTED
/1
2/
A
IN
TE
R N
AL
Q
C
AG
S
/2 0/
B
C
LI
EN
T R
EV
IE
W
AG
S
/1 3/
C
BI
D D
IN
G
AG
S
C O
N
ST
R U
C
TI
O N
D
ET
AI
LS
C
IV
IL
STRENGTH OF 3000 PSI AT THE END OF 28 DAYS
NOTE: ALL CONCRETE SHALL HAVE MINIMUM COMPRESSIVE
EXISTING WATER / STORM SEWER
NEW SEWER MAIN
EXIST. GRADE
" M
IN
8" 8"
8"8"
SCALE:3 NONE
EXISTING WATER/STORM SEWER UTILITY DETAIL
NEW SEWER LINE CROSSING UNDER
M
IN
3' -0
M
IN
WHEN VERTICAL SEPARATION IS LESS THAN
18" PROVIDE CONCRETE ENCASEMENT ON
UNDISTURBED GROUND. THE LENGTH OF THE
ENCASEMENT SHALL BE EXTENDED A MINIMUM OF
3 FEET BEYOND THE CENTERLINE OF THE STORM
SEWER (OR OTHER UTILITY) IN BOTH DIRECTIONS
SCALE:5 NONE
TYPICAL CONNECTION TO EXISTING MANHOLE
3'-0"+-
TYP. BOTH SIDES
SDR-26 COUPLING
(TYP. BOTH SIDES)
PROPOSED PVC PIPE PROPOSED PVC PIPE
SCALE:4 NONE
OUTSIDE DROP MANHOLE DETAIL
INSIDE DROP SANITARY EXISTING
NOTES:
1. CORE DRILL 4" LARGER THAN INFLUENT PIPE DIAMETER. PROVIDE A-LOK G3 BOOT SYSTEM.
INFLUENT
PVC PIPE DIA. EQUALS
INFLUENT PIPE DIA. PLUS 2"
STAINLESS STEEL
BANDS (2 MINIMUM)
W (2) A-316 BOLTS AND
ANCHORS@ 48" O.C.
A-LOK BOOT
SYSTEM SEAL (NOTE #1)
INSIDE DROP BOWL
(RELINER/DURAN INC.
OR EQUAL)
90° BEND
COMPOSITE
GRADE RINGS (VARIES,
MIN. 6", MAX. 12")
FILL OUTSIDE DROP
WITH CONCRETE
CONNECT TO EXISTING SANITARY
SEWER W/ SDR-26 COUPLING
SCALE:1 NONE
MANHOLE GRADE ADJUSTMENT DETAIL
PROPOSED SDR-26 PIPE
SCALE:2 NONE
SANITARY SEWER MAIN REPLACEMENT DETAIL
SDR-26 COUPLING
(TYP. BOTH SIDES)
EXISTING SANITARY SEWER
FL
O
W
SECTION
PLAN
SEWER MAIN
WYE
6" PVC BEND(S) AS REQUIRED
6" PVC SEWER LATERAL
6" PVC LATERAL SLOPE 1/4" PER FT. MIN.
6" BEND(S) AS REQUIRED
HOUSE LATERAL (BY OTHERS) WYE
SCALE:6 NONE
SANITARY SEWER LATERAL DETAIL
CONNECT TO EXISTING LATERAL
W/ SHIELDED FLEXIBLE COUPLING
3'
SDR-26 COUPLING
(TYP. BOTH SIDES)
6'-0"
PROVIDE HDPE MANHOLE INSERT
IV
IL
R
ES
TO
R
AT
IO
N
D
ET
AI
LS
4713.005
A
B
2 3
C
D
1 2 3
4 5 6
PROJECT NO.
APPROVED BY:
SCALE:
CHECKED BY:
PREPARED BY:
A
B
D
AT
E R
EV
4 5
IS
SU
ED
F
O R
/R
EV
IS
ED
C
AP
PD
D
DRAWING NO.
Entech Engineering - Printed: Nov. 13, 2026 H:\0004713.005\04-CAD\SheetFiles\C-701.dwgLa st
E di te d by : A
A tti ck
C-701
NO
RT
HE
RN
L
AN
CA
ST
ER
C
O
UN
TY
A
UT
HO
RI
TY
BR
EC
KN
O
C K
TO
W
N
SH
IP
, L
AN
C
AS
TE
R C
O U
N
TY
, P
EN
N
SY
LV
AN
IA
W M
AP
LE
G
RO
VE
R
OA
D
AN
D
FI
VE
PO
IN
TV
IL
LE
R
OA
D
SE
W
ER
R
EP
AI
RS
AGS
ARA
AS NOTED
/1
2/
A
IN
TE
R N
AL
Q
C
AG
S
/2 0/
B
C
LI
EN
T R
EV
IE
W
AG
S
/1 3/
C
BI
D D
IN
G
AG
S
REFER TO TRENCH
RESTORATION DETAILS
6" TOPSOIL AND SEED
ALL DISTURBED AREAS
1'-0"
CUTBACK
(TYP.)
SCALE:1 NONE
FOR GRASS AREAS
SURFACE RESTORATION DETAIL
1'-0"
CUTBACK
(TYP.)
REFER TO TRENCH
RESTORATION DETAILS
SCALE:2 FOR PAVED ROADWAY
SURFACE RESTORATION DETAIL
SAW-CUT FULL DEPTH
EXIST. PAVEMENT
(INITIAL SAW-CUT) (TYP.)
SAW-CUT FULL DEPTH
EXIST. PAVEMENT (TYP.)
1-1/2" SUPERPAVE ASPHALT DESIGN,
9.5MM, PG 64s-22, SRL H, WEARING COURSE
12" WIDE BITUMINOUS
SEAL PG 64s-22 (TYP.)
2-1/2" MIN. SUPERPAVE ASPHALT DESIGN,
19.0 MM, PG 64s-22, BINDER OR TO A DEPTH
OF EXIST. BINDING COURSE, WHICHEVER
IS GREATER (IF REQUIRED)
5" MIN. SUPERPAVE ASPHALT DESIGN,
25.0 MM, PG 64s-22, BASE OR TO A DEPTH
OF EXIST. BASE COURSE, WHICHEVER
IS GREATER
NOTES:
1. EXISTING PAVEMENT MARKINGS SHALL BE REPLACED IF DISTURBED.
NONE
PENNDOT PAVEMENT RESTORATION NOTES:
1. RESTORE WITH SUPERPAVE (25mm) TO SURFACE AND ALLOW TO SETTLE FOR 90 DAYS.
SUPERPAVE DEPTH OF 6-1/2" OR TO MATCH EXISTING PAVING, WHICHEVER IS GREATER.
2. MILL RESTORED AREA PLUS 1 FOOT TO EACH SIDE OF TRENCH TO 1-1/2" DEPTH.
3. PAVE MILLED AREA WITH 2.0" SPV (9.5mm).
4. SEAL EDGES WITH PG64S-22.
5. PAVEMENT SAWCUTTING SHALL PROVIDE A CLEAN AND NEAT EDGE AT RIGHT ANGLES OF
SURFACE OF PAVEMENT TO REMAIN.
6. ALL BACKFILL WITHIN OR ACROSS THE PENNDOT ROAD MUST BE TESTED FOR 100%
COMPACTION AND 4-INCH LIFTS MUST BE TAMPED.
7. ALL PAVEMENT MARKINGS, WHICH ARE DISTURBED, SHALL BE REPLACED IN KIND WITH
CURRENT PENNDOT STANDARDS AND SPECIFICATIONS.
6" M
IN
TRENCH WIDTH
AA
SH
TO
N
O . 8
M
AT
ER
IA
L
SH
AL
L
M
EE
T
TH
E R
EQ
U
IR
EM
EN
TS
O F
PE
N
N D
O T
PU
BL
IC
AT
IO
N
, 1
P
R O
C
TO
R D
EN
SI
TY
C
O M
PA
C
TE
D
IN
4"
L
IF
TS
, 8
" V
IB
R
AT
O R
Y
PROPOSED PIPE
TEMPORARY AND PERMANENT
PAVEMENT RESTORATION
PERMANENT PAVING
CROSS SECTION AS
REQUIRED BY STATE
OR TOWNSHIP
12"
UTILITY
WARNING TAPE
2A COARSE
AGGREGATE BACKFILL
4' -0
" M
IN
IM
U
M C
O
VE
R
TEMPORARY PERMANENT
TEMPORARY
PAVEMENT 6-1/2"
MIN. SUPERPAVE (25 mm)
12" 12"
SEAL EDGE WITH PG64S-22
(RESTORATION ONLY)
2" WEARING COURSE
SCALE:3 NONE
PAVED AREAS WITHIN PENNDOT RIGHT-OF-WAY
TRENCH RESTORATION DETAIL FOR EXISTING
SPAV, WRG, PG 64S-22, 12.5 MM MIX,
3.0 TO < 10.0 MILLION ESALS,
DEPTH 2.0", SRL-H
O
N
TR
O L
D
ET
AI
LS
ER
O
SI
O
N A
N D
S
ED
IM
EN
TA
TI
O N
2 MIN. (TYP.)
INSTALLATION DETAIL
ISOMETRIC VIEW
PLAN VIEW
SCALE:3 NONE
FILTER BAG INLET PROTECTION - TYPE M INLET
STANDARD CONSTRUCTION DETAIL #4-16
2'
4'
3'
WIDTH LENGTH
FLOW
ELEVATION VIEW FLOW
NOTES:
1. MAXIMUM DRAINAGE AREA= 1/2 ACRE
2. INLET PROTECTION SHALL NOT BE REQUIRED FOR INLET TRIBUTARY TO SEDIMENT BASIN OR TRAP.
BERMS SHALL BE REQUIRED FOR ALL INSTALLATIONS.
3. ROLLED EARTHEN BERM SHALL BE PROVIDED AND MAINTAINED IMMEDIATELY DOWN GRADIENT OF THE PROTECTED INLET UNTIL ROADWAY IS STONED. ROAD SUB-BASE BERM SHALL BE MAINTAINED UNTIL ROADWAY IS PAVED. SIX INCH MINIMUM HEIGHT ASPHALT BERM SHALL BE MAINTAINED UNTIL
ROADWAY SURFACE RECEIVES FINAL COAT.
4. AT A MINIMUM, THE FABRIC SHALL HAVE A MINIMUM GRAB TENSILE STRENGTH OF 120 LBS, A MINIMUM BURST STRENGTH OF 200 PSI, AND A MINIMUM TRAPEZOIDAL TEAR STRENGTH OF 50 LBS. FILTER
BAGS SHALL BE CAPABLE OF TRAPPING ALL PARTICLES NOT PASSING A NO. 40 SIEVE.
5. INLET FILTER BAGS SHALL BE INSPECTED ON A WEEKLY BASIS AND AFTER EACH RUNOFF EVENT.
BAGS SHALL BE EMPTIED AND RINSED OR REPLACED WHEN HALF FULL OR WHEN FLOW CAPACITY
HAS BEEN REDUCED SO AS TO CAUSE FLOODING OR BYPASSING OF THE INLET. DAMAGED OR
CLOGGED BAGS SHALL BE REPLACED. A SUPPLY SHALL BE MAINTAINED ON SITE FOR REPLACEMENT OF BAGS. ALL NEEDED REPAIRS SHALL BE INITIATED IMMEDIATELY AFTER THE INSPECTION. DISPOSE
OF ACCUMULATED SEDIMENT AS WELL AS ALL USE BAGS ACCORDING TO THE PLAN NOTES
6. DO NOT USE ON MAJOR PAVED ROADWAYS WHERE PONDING MAY CAUSE TRAFFIC HAZARDS.
EXPANSION RESTRAINT
(1/4" NYLON ROPE)
2" x 2" x 3/4"
RUBBER BLOCK
1" REBAR FOR
BAG REMOVAL
FROM INLET
REMOVAL
FROM INLET
6" MIN. HEIGHT
BERM
3:1
EARTHEN BERM TO BE STABILIZED
W/ TEMPORARY OR PERMANENT
VEGETATION
2 MIN. : 1STORM
INLET
EXTEND BERM OVER CURB
IF RUN-OFF IS BYPASSING
INLET ON LANDWARD SIDE
GENERAL SHEET NOTES
1. REFER TO DRAWING G-001 FOR DRAWING INDEX, GENERAL PROJECT
NOTES, LEGEND & DRAWING CONVENTIONS.
4713.005
A
B
2 3
C
D
1 2 3
4 5 6
PROJECT NO.
APPROVED BY:
SCALE:
CHECKED BY:
PREPARED BY:
A
B
D
AT
E R
EV
4 5
IS
SU
ED
F
O R
/R
EV
IS
ED
C
AP
PD
D
DRAWING NO.
Entech Engineering - Printed: Nov. 13, 2026 H:\0004713.005\04-CAD\SheetFiles\ES-501.dwgLa st
E di te d by : A
A tti ck
ES-501
NO
RT
HE
RN
L
AN
CA
ST
ER
C
O
UN
TY
A
UT
HO
RI
TY
BR
EC
KN
O
C K
TO
W
N
SH
IP
, L
AN
C
AS
TE
R C
O U
N
TY
, P
EN
N
SY
LV
AN
IA
W M
AP
LE
G
RO
VE
R
OA
D
AN
D
FI
VE
PO
IN
TV
IL
LE
R
OA
D
SE
W
ER
R
EP
AI
RS
AGS
ARA
AS NOTED
/1
2/
A
IN
TE
R N
AL
Q
C
AG
S
/2 0/
B
C
LI
EN
T R
EV
IE
W
AG
S
/1 3/
C
BI
D D
IN
G
AG
S
SCALE:1 NONE
PUMPED WATER FILTER BAG
STANDARD CONSTRUCTION DETAIL #3-16
LOW VOLUME FILTER BAGS SHALL BE MADE FROM NON-WOVEN GEOTEXTILE MATERIAL
SEWN WITH HIGH STRENGTH, DOUBLE STITCHED "J" TYPE SEAMS. THEY SHALL BE
CAPABLE OF TRAPPING PARTICLES LARGER THAN 151 MICRONS. HIGH VOLUME FILTER
BAGS SHALL BE MADE FROM WOVEN GEOTEXTILES THAT MEET THE FOLLOWING
STANDARDS:
PROPERTY TEST METHOD MINIMUM STANDARD
AVG. WIDE WIDTH STRENGTH ASTM D-4884 60 lb/in
GRAB TENSILE ASTM D-4632 205 lb
PUNCTURE ASTM D-4833 110 lb
MULLEN BURST ASTM D-3786 350 psi
UV RESISTANCE ASTM D-4355 70%
AOS % RETAINED ASTM D-4751 80 Sieve
NOTES:
1. A SUITABLE MEANS OF ACCESSING THE BAG WITH MACHINERY REQUIRED FOR DISPOSAL PURPOSES SHALL BE PROVIDED. FILTER BAGS SHALL BE REPLACED WHEN THEY BECOME 1/2 FULL OF SEDIMENT.
SPARE BAGS SHALL BE KEPT AVAILABLE FOR REPLACEMENT OF THOSE THAT HAVE FAILED OR ARE FILLED. BAGS SHALL BE PLACED ON STRAPS TO FACILITATE REMOVAL UNLESS BAGS COME WITH
LIFTING STRAPS ALREADY ATTACHED.
2. BAGS SHALL BE LOCATED IN WELL-VEGETATED (GRASSY) AREA, AND DISCHARGE ONTO STABLE, EROSION RESISTANT AREAS. WHERE THIS IS NOT POSSIBLE, A GEOTEXTILE UNDERLAYMENT AND FLOW
PATH SHALL BE PROVIDED. BAGS MAY BE PLACED ON FILTER STONE TO INCREASE DISCHARGE
CAPACITY. BAGS SHALL NOT BE PLACED ON SLOPES GREATER THAN 5%. FOR SLOPES EXCEEDING 5%, CLEAN ROCK OR OTHER NON-ERODIBLE AND NON-POLLUTING MATERIAL MAY BE PLACED UNDER THE
BAG TO REDUCE SLOPE STEEPNESS.
3. NO DOWNSLOPE SEDIMENT BARRIER IS REQUIRED FOR MOST INSTALLATIONS. COMPOST BERM OR COMPOST FILTER SOCK SHALL BE INSTALLED BELOW BAGS LOCATED IN HQ OR EV WATERSHEDS, WITHIN 50 FT. OF ANY RECEIVING SURFACE WATER OR WHERE GRASSY AREA IS NOT AVAILABLE.
4. THE PUMP DISCHARGE HOSE SHALL BE INSERTED INTO BAGS IN THE MANNER SPECIFIED BY THE
MANUFACTURER AND SECURELY CLAMPED. A PIECE OF PVC PIPE IS RECOMMENDED FOR THIS
PURPOSE.
5. THE PUMPING RATE SHALL BE NO GREATER THAN 750 GPM OR 1/2 THE MAXIMUM SPECIFIED BY THE
MANUFACTURER, WHICHEVER IS LESS. PUMP INTAKES SHALL BE FLOATING AND SCREENED.
6. FILTER BAGS SHALL BE INSPECTED DAILY. IF ANY PROBLEM IS DETECTED, PUMPING SHALL CEASE
IMMEDIATELY AND NOT RESUME UNTIL THE PROBLEM IS CORRECTED.
FILTER BAG
FILTER BAG
WELL VEGETATED, GRASSY AREA
PUMP
INTAKE HOSE
CLAMPS
DISCHARGE HOSE
HEAVY DUTY LIFTING STRAPS
(RECOMMENDED)
INTAKE HOSE
CLAMPS
DISCHARGE HOSE
PUMP
WELL VEGETATED, GRASSY AREA
ELEVATION VIEW
PLAN VIEW
COMPOST FILTER
SOCK RING REQUIRED
FOR THIS INSTALLATION
NOTE:
FOR SPECIAL PROTECTION WATERSHED, COMPOST BERM OR COMPOST FILTER SOCK SHALL
BE INSTALLED BELOW BAGS LOCATED IN HQ OR EV WATERSHEDS, WITHIN 50 FT. OF ANY
RECEIVING SURFACE WATER OR WHERE GRASSY AREA IS NOT AVAILABLE.
2 MIN.(TYP.)
1' MIN.
CURB
INSTALLATION DETAIL
ISOMETRIC VIEW
PLAN VIEW
SCALE:2 NONE
FILTER BAG INLET PROTECTION - TYPE C INLET
STANDARD CONSTRUCTION DETAIL #4-15
2'
4'
3'
WIDTH LENGTH
TOP OF CURB
FLOW
ELEVATION VIEW
EXTEND BERM OVER CURB
IF RUNOFF IS BYPASSING
INLET ON LANDWARD SIDE
NOTES:
1. MAXIMUM DRAINAGE AREA= 1/2 ACRE
2. INLET PROTECTION SHALL NOT BE REQUIRED FOR INLET TRIBUTARY TO SEDIMENT BASIN OR
TRAP. BERMS SHALL BE REQUIRED FOR ALL INSTALLATIONS.
3. ROLLED EARTHEN BERM SHALL BE PROVIDED AND MAINTAINED IMMEDIATELY DOWN GRADIENT
OF THE PROTECTED INLET UNTIL ROADWAY IS STONED. ROAD SUB-BASE BERM SHALL BE
MAINTAINED UNTIL ROADWAY IS PAVED. SIX INCH MINIMUM HEIGHT ASPHALT BERM SHALL BE
MAINTAINED UNTIL ROADWAY SURFACE RECEIVES FINAL COAT.
4. AT A MINIMUM, THE FABRIC SHALL HAVE A MINIMUM GRAB TENSILE STRENGTH OF 120 LBS, A
MINIMUM BURST STRENGTH OF 200 PSI, AND A MINIMUM TRAPEZOIDAL TEAR STRENGTH OF 50
LBS. FILTER BAGS SHALL BE CAPABLE OF TRAPPING ALL PARTICLES NOT PASSING A NO. 40
SIEVE.
5. INLET FILTER BAGS SHALL BE INSPECTED ON A WEEKLY BASIS AND AFTER EACH RUNOFF EVENT.
BAGS SHALL BE EMPTIED AND RINSED OR REPLACED WHEN HALF FULL OR WHEN FLOW
CAPACITY HAS BEEN REDUCED SO AS TO CAUSE FLOODING OR BYPASSING OF THE INLET.
DAMAGED OR CLOGGED BAGS SHALL BE REPLACED. A SUPPLY SHALL BE MAINTAINED ON SITE
FOR REPLACEMENT OF BAGS. ALL NEEDED REPAIRS SHALL BE INITIATED IMMEDIATELY AFTER
THE INSPECTION. DISPOSE OF ACCUMULATED SEDIMENT AS WELL AS ALL USE BAGS ACCORDING
TO THE PLAN NOTES
6. DO NOT USE ON MAJOR PAVED ROADWAYS WHERE PONDING MAY CAUSE TRAFFIC HAZARDS.
SANDBAG, FILTER LOG,
COMPOST SOCK OR
FILTER TUBE
EXPANSION RESTRAINT
(1/4" NYLON ROPE)
2" x 2" x 3/4"
RUBBER BLOCK
1" REBAR FOR BAG REMOVAL FROM
INLET REMOVAL FROM INLET
BERM
BERM
STORM
INLET
| Sheets and Views |
| G-001-NLCA |
| G-101-NLCA |
| C-101-NLCA |
| C-102-NLCA |
| C-103-NLCA |
| C-104-NLCA |
| C-501-NLCA |
| C-701-NLCA |
| ES-501-24x36 |
File details come from the government source that posted it. Updated .