2-Hill Road Storm Sewer Plan FINAL.pdf
PDF 5 MB Posted
- Attached to
- Earl Township Hill Road Storm Sewer Project
- Solicitation number
- Not on record
- Issued by
- Berks County, Pennsylvania
About this file
This is a Storm Sewer Improvement Plan document prepared for Hill Road in Earl Township, Berks County, Pennsylvania, by HNT, LLC. The plan details the design and engineering specifications for a comprehensive storm sewer infrastructure project. The scope of work includes installation of approximately 649 linear feet of 24-inch HDPE pipe, 26 linear feet of 15-inch HDPE pipe, six Type 1 M inlet boxes, two endwalls (one downstream and one at the outlet), and one riprap apron at the pipe outlet. The project also encompasses removal of existing 15-inch CMP pipe (54 linear feet), installation of inlet protection measures using compost filter socks and stone/concrete blocks, pavement restoration with trench detail specifications, and swale grading for drainage conveyance. The plan includes detailed construction details for precast concrete inlet boxes, endwall configurations, riprap apron design, and erosion control measures. Elevations are referenced to NAVD88 datum using Pennsylvania State Plane South Coordinates. The project is situated within a 50-foot right-of-way along Hill Road and affects multiple property parcels in the township.
The engineering plan provides comprehensive technical specifications including pipe slopes ranging from 1.5 percent to 12.8 percent, inlet invert elevations, and detailed construction sequencing. Trench restoration specifications call for clean fill compacted in eight-inch layers, PENNDOT 2A modified stone in six-inch compacted layers, and Superpave asphalt pavement with specific depths and performance grades (PG 64-22). Erosion control measures include compost filter socks, earthen berms, and inlet filter bags requiring weekly inspection and maintenance. The plan document, prepared June 18, 2026, provides a detailed basis for bidding and construction, with all design details conforming to PADEP standard construction details and PA DOT Publication 408 standards for roadway construction.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
M
A
I
L
B
O
X
M
A
I
L
B
O
X
E
S
M
A
I
L
B
O
X
M
A
I
L
B
O
X
M
A
I
L
B
O
X
X
X
M
A
I
L
B
O
X
M
A
I
L
B
O
X
E
S
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
E
X
D
R
I
V
E
I
V
E
I
V
E
I
V
E
I
V
E
I
V
E
I
V
E
I
V
E
E
X
I
S
T
I
N
G
O
A
D
S
I
S
W
A
L
E
A
D
S
I
D
E
S
W
A
L
E
H
P
E
I
N
V
I
N
V
I
N
V
I
N
V
P
E
C
P
I
N
V
I
N
V
P
E
I
N
V
I
N
V
B
R
N
U
P
T
A
S
H
A
O
N
O
W
S
K
I
I
N
I
L
A
D
E
D
R
U
K
T
I
N
A
D
W
I
L
L
I
T
S
C
J
T
S
C
H
E
I
N
A
D
M
A
N
D
E
R
L
I
C
H
I
N
A
D
C
I
N
Y
E
E
T
Z
I
N
A
D
J
A
M
A
T
H
L
I
T
Y
I
N
A
D
S
U
S
E
T
O
O
S
I
N
A
D
A
D
S
S
I
N
A
D
R
O
B
E
Y
I
R
E
Y
I
N
A
D
M
A
R
V
Y
E
R
I
N
A
D
H
I
A
D
E
X
I
S
T
I
W
E
X
I
S
T
I
W
INLET I-1
INSTALL TYPE 1 M INLET
INV IN: 533.0
INV OUT: 532.8
T/G: 536.5
INLET I-2
INSTALL TYPE 1 M INLET
INV IN: 515.0
INV OUT: 514.8
T/G: 518.5
INLET I-3
INSTALL TYPE 1 M INLET
INV IN NEW 15" HDPE: 510.48
INV IN: 510.3
INV OUT: 510.1
T/G: 513.85
EX 15" CMP PIPE
TO BE REMOVED
INSTALL NEW
15" HDPE PIPE
26 LF @ 5.3%
INLET I-5
INSTALL TYPE 1 M INLET
INV IN: 502.0
INV OUT: 501.8
T/G: 506.0
INLET I-6
INSTALL TYPE 1 M INLET
INV IN: 501.0
INV OUT: 500.8
T/G: 505.50
HEADWALL HW-1
INSTALL DW HEADWALL
INV IN: 538.0
TW: 541.0
40 LF OF 24"
HDPE @ 12.5%
RESTORE DRIVEWAY
AFTER PIPE
INSTALL
139 LF OF 24"
HDPE @ 12.8%
164 LF OF 24"
HDPE @ 2.7%
38 LF OF 24"
HDPE @ 4.2%
168 LF OF 24"
HDPE @ 3.8%
48 LF OF 24"
HDPE @ 4.8%
U
R
C
I
N
U
INLET I-4
INSTALL TYPE 1 M INLET
INV IN: 508.5
INV OUT: 508.3
T/G: 512.0
52 LF OF 24"
HDPE @ 1.5%
REMOVE EXISTING
15" HDPE (54 LF)
UNDER ROADWAY
ENDWALL EW-1
INSTALL DW ENDWALL
INV OUT: 498.5
TW: 502.0
RIPRAP APRON RR-1
R-4 18" DEPTH
10' LONG X 10' WIDE AT END
I
P
I
P
I
P
I
P
I
P
I
P
22 LF OF 24" CFS
156 LF OF 24" CFS
172 LF OF 24" CFS
45 LF OF 24" CFS
171 LF OF 24" CFS
26 LF OF 24" CFS
REVISIONS
DRAWN CHECK SCALE
AS NOTED
PLAN NO.
SHEET
2026 HNT, LLC
C
06/18/2026
25-094
OF 03
Situate In:
Earl Township
Berks County, Pennsylvania
297 SUEDBERG ROAD, SUITE #7, PINE GROVE, PA 17963
(570) 345-8288 FAX: (570) 345-8299
EXISTING GROUND CONTOUR LINE
PLAN LEGEND
PROPOSED FEATURE
EXISTING FEATURE
SLANT LETTERING
VERTICAL LETTERING
PROPERTY LINE
RIGHT-OF-WAY LINE
STORM SEWER IMPROVEMENT
PLAN
FOR
HILL ROAD
NOTES:
1. BOUNDARY LOCATIONS ARE REPRESENTED BY TAX
PARCEL MAPPING.
2. ROAD RIGHT-OF-WAY DEPICT HILL ROAD AS 50'
RIGHT-OF-WAY
3. PA STATE PLANE SOUTH COORDINATE SYSTEM GPS
RTK
4. ELEVATION DATUM NAVD88
5. ALL INLETS SHALL BE TYPE 1
6. STORM SEWER PIPE LENGTHS ARE COMPUTED FROM
CENTER OF INLET BOX TO CENTER OF INLET BOX.
- STOP -
CALL BEFORE YOU DIG
PENNSYLVANIA ONE CALL SYSTEM, INC.
3 WORKING DAYS NOTICE IS THE LAW!
1-800-242-1776
S
Y
S
T
E
M
V
C
O
N
E
A
L
L
C
N
I
S
E
N
N
S
Y
L
A
N
I
A
P
T
O
P
C
A
L
L
B
EF
O
R
E
Y
O
U
D
I
G
LOCATION MAP
1" = 2,000'
PROJECT
AREA
0 30 60 90
24" COMPOST FILTER SOCK
IP
-1
IP
-1
IP
-2
INLET PROTECTION (DETAIL 4-16)
INLET PROTECTION (DETAIL 4-18)
INLET PROTECTION (DETAIL 4-20)
Heath Machamer 6/18/2026
REVISIONS
DRAWN CHECK SCALE
AS NOTED
PLAN NO.
SHEET
2026 HNT, LLC
C
06/18/2026
25-094
OF 03
Situate In:
Earl Township
Berks County, Pennsylvania
297 SUEDBERG ROAD, SUITE #7, PINE GROVE, PA 17963
(570) 345-8288 FAX: (570) 345-8299
STORM SEWER IMPROVEMENT
PLAN
FOR
HILL ROAD
RIPRAP APRON AT PIPE OUTLET
WITH FLARED END SECTION OR ENDWALL
NOTES:
ALL APRONS SHALL BE CONSTRUCTED TO THE DIMENSIONS SHOWN. TERMINAL WIDTHS
SHALL BE ADJUSTED AS NECESSARY TO MATCH RECEIVING CHANNELS.
ALL APRONS SHALL BE INSPECTED AT LEAST WEEKLY AND AFTER EACH RUNOFF
EVENT. DISPLACED RIPRAP WITHIN THE APRON SHALL BE REPLACED IMMEDIATELY.
0% SLOPE
PLAN VIEW
SECTION Y-Y
SECTION Z-Z
AI
AI
Atw
Pd
Rt
Aiw
Pd
Y Y
Z
Z
OUTLET
NO.
PIPE
DIA
Pd
(IN)
RIPRAP APRON
SIZE
R-_
THICK.
Rt
(IN)
LENGTH
Al
(FT)
INITIAL
WIDTH
Aiw
(FT)
TERMINAL
WIDTH
Atw
(FT)
PADEP STANDARD CONSTRUCTION DETAIL #9-1
GEOTEXTILE
0% SLOPE
GEOTEXTILE
24 R-4 18 10 6 10
RR-1
-SIDE VIEW-
-PLAN VIEW-
-ISOMETRIC-
TOP RISER SECTION
33"
43"
8"
26"
26"
30°
52"
8"
26"
12"
6"
8"
PIPE ∅
6"
NOTES:
1. HEADWALLS, ENDWALL, AND END SECTIONS
SHALL BE SET ON A MINIMUM OF 12" AASHTO
NO. 57 (PENNDOT 2B) COARSE AGGREGATE.
NO SCALE
TYPE D-W ENDWALL DETAIL
1' MIN.
L
NO SCALE
W
ENDSECTION DETAIL
(AS MANUFACTURED BY ADS OR APPROVED EQUAL)
-SIDE-
B
-TOP-
A
H
P
I
-END-
A
L
H
PIPE DIA A Bmax H L W
12", 15" 6.5" 10" 6.5" 25" 29"
18" 7.5" 15" 6.5" 32" 35"
24" 7.5" 18" 6.5" 36" 45"
30" 10.5" NA 7.0" 53" 68"
36" 10.5" NA 7.0" 53" 68"
ENDSECTION DIMENSIONS
NOTE: USE ENDSECTION WITH
COLLAR ABOVE PIPE FOR SOIL
CONTAINMENT (WHERE AVAILABLE)
PRECAST INLET BOX BASE PREPARATION
NO SCALE
NO SCALE
(RC-34) PRECAST CONCRETE INLET BOXES
1. ALL CAST-IN-PLACE INLET TOPS SHALL CONFORM TO THE SHAPE
AND DIMENSIONS AS SHOWN ON THE STANDARD, AND AT THE OPTION
OF THE CONTRACTOR, MAY BE MONOLITHIC WITH THE INLET BOX.
2. CONCRETE TOP UNITS WHICH SEAT THE GRATE DIRECTLY WITHIN
THE
UNIT SHALL UTILIZE 1-1/4" X 1-1/4" ANGLES EMBEDDED IN THE
CONCRETE AS A BEARING AREA FOR THE GRATE.
3. THIS STANDARD DEPICTS THE SHAPE AND DIMENSIONS REQUIRED
FOR
UNIFORMITY AND COMPATIBILITY. IT IS NOT INTENDED TO SHOW THE
DETAILS REQUIRED FOR MANUFACTURING AND HANDLING. ONLY THOSE
ITEMS WHICH ARE SUPPLIED BY AN APPROVED MANUFACTURER AS
LISTED IN PA BULLETIN NO. 15 WILL BE PERMITTED.
4. THE SELECTION OF COMPONENTS TO ACHIEVE A SPECIFIED INLET
TYPE
IS THE CONTRACTOR'S RESPONSIBILITY.
5. PIPES SHALL BE LOCATED AS REQUIRED.
6. WEEP HOLES SHALL BE INSTALLED AS REQUIRED BY SECTION 605,
PA DOT FORM 408.
7. GRADE ADJUSTMENT RINGS MAY BE OF MASONRY OR PRECAST
CONCRETE CONSTRUCTION, AS APPROVED.
8. INLET BOX SHALL EITHER CAST-IN-PLACE CONCRETE, OR PRECAST
CONCRETE.
9. REFER TO PA DOT BUREAU OF DESIGN STANDARDS RC-34M.
10. ALL NEW CONSTRUCTION SHALL BE IN ACCORDANCE WITH PADOT
PUBLICATION 408, SECTION 605 & STANDARDS FOR ROADWAY
CONSTRUCTION, RC-34M. CONTRACTOR SHALL VERIFY INLET BOX
SIZING BASED ON PIPE SIZES AND ALIGNMENT PRIOR TO ORDERING
PRECAST STRUCTURES.
11. ALL DRAINAGE STRUCTURES SHALL HAVE POURED-IN-PLACE
CONCRETE
CHANNEL BOTTOMS.
12. SEAL AROUND UNIT TOP AND PAVING (ALL UNITS) WITH AC-20.
13. INLETS DEEPER THAN 6 FT. FROM TOP OF GRATE SHALL BE
EQUIPPED WITH METAL STEPS.
14. ALL INLET TOPS SHALL BE CONSTRUCTED WITH A 2" SUMP (10"
REVEAL AT ALL INLETS TO MATCH 8" CURB REVEAL ELSEWHERE).
15. FOR DOUBLE INLET BOX CONFIGURATION, REMOVE CENTER
KNOCKOUT PANELS AND GROUT JOINT CLOSED. JOINED STRUCTURE
SHALL HAVE POURED-IN-PLACE CONCRETE CHANNEL BOTTOM WITH
INVERT PER PLAN.
16. PLACE SUBBASE MATERIAL MEETING THE REQUIREMENTS OF
PENNDOT PUBLICATION 408, SECTION 350.2, IN LAYERS OF 4" THICK,
COMPACTED TO A DENSITY SATISFACTORY TO THE BOROUGH ENGINEER
(SEE DETAIL A).
(RC-34) PRECAST CONCRETE
TYPE M INLET TOP DETAIL
#4 BARS2-12"1-12"
6"
8"
24"
-SECTION-
-PLAN-
48-14"
57-14"
STRUCTURAL STEEL
GRATE (BICYCLE SAFE)
NO SCALE
PROVIDE ONE LAYER
OF REINF. BARS
(0.12 SQIN/FT.)
EACH WAY MIN
#4 BARS 12" C. TO C. (TYP)
EACH WAY TOP & BOTTOM
OR 0.20 SQIN/FT W.W.F.
(6" MAX SPACING)
PROVIDE ONE LAYER
OF REINF. BARS
(0.12 SQIN/FT.)
EACH WAY MIN
#4 BARS 12" C. TO C. (TYP)
EACH WAY TOP & BOTTOM
OR 0.20 SQIN/FT W.W.F.
(6" MAX SPACING)
38"
COVER ADJUSTMENT SLAB
TYPE 1
SECTION B-B
6" MIN
6"
M A X
H E I G H T
4" MIN
M I N
6"
A
T Y P
57-1/4"
STANDARD BOX
A
B
6" MIN
M A X
O D
M A X
H E I G H T
6" (TYP)
36" ∅ MAX
FOR RCP
STANDARD BOX EXPANDED IN
THE SHORT DIRECTION
TYPE 1
M A X
O D
SECTION A-A
B
57-1/4"
INLET NOTES
(RC-34) STRUCTURAL STEEL GRATE
BICYCLE SAFE
1/4" MIN
(TYP)
1/4" MIN
6 TRANSVERSE RODS
AT 3-5/8" C. TO C. (TYP)
3/8"∅ x 46-1/4" ROD
SECTION A-A
3' 11-3/4"
A
1-1/4"
3/4"
NO SCALE
26 BEARING BARS
AT 1-3/4" C. TO C. (TYP)
1/2" x 2-1/2" x 25" BAR
S E C T I O N
B B
A
B
3/4"
B
3/4"
2-1/2"
4"MIN.
MAX.
9'-0"
HEIGHT
A A
A
A
A A
7"
6"MIN.
COVER ADJUSTMENT SLAB
TYPE 2
SECTION C-C
PROVIDE
ONE LAYER OF
REINF. BARS
(0.12 in /FT.)
EACH WAY MIN.
AA
6"
A AAA
6"59.25"
DETAIL A
SUBBASE MATERIAL
12" MIN. SEE NOTE 16
COVER ADJUSTMENT SLAB
SECTION G-G
NO SCALE
TYPE 1
N
M I N
SECTION F-F
71 1/4''
57 1/4''
FF
57 1/4''
#5 BARS
6''
45 1/4''
SUPERPAVE ASPHALT MIXTURE DESIGN HMA
9.5MM WEARING COURSE, PG 64-22, 0.3 TO 3.0
MILLION ESALS, 1.5" DEPTH
SUPERPAVE ASPHALT MIXTURE
DESIGN HMA 25MM BASE COURSE,
PG 64-22, 0.3 TO 3.0 MILLION
ESALS, 5" DEPTH
PENNDOT 2A MODIFIED STONE
COMPACTED IN 6" LAYERS
EARL TOWNSHIP
TRENCH RESTORATION DETAIL
NOTES:
1. EXPOSED VERTICAL AND
HORIZONTAL SURFACES SHALL BE
PREPARED AS PER PUB 408,
SECTION 409.3.(g)
2. MINIMUM 1' PAVEMENT CUTBACK,
EXCAVATE OLD AND TEMPORARY
MATERIAL. RECOMPACT SUB-GRADE,
TACK COAT ALL VERTICAL EDGES.
INSTALL BASE COURSE AND
WEARING COURSE ON SEPARATE
DAYS.
3. TOWNSHIP ENGINEER MUST
OBSERVE STONE BACKFILL
COMPACTION.
4. MATCH EXISTING PAVING DEPTHS IF
GREATER.
5. HOT SEAL ALL EDGES W/ 12" WIDE
PG 64-22.
6. CLEAN FILL SHALL HAVE NO STONE
SIZE LARGER THAN 6".
1' MIN
6" MIN
1' MIN
6" MIN
CLEAN FILL COMPACTED IN 8"
LAYERS
PENNDOT 2A MODIFIED STONE
COMPACTED IN 6" LAYERS6" MIN
6" MIN
12" MIN
PAVED AREAS GRASS AREAS
ROADWAY SHOULDER TO BE
SWALED A MINIMUM 2' WIDE WITH
MINIMUM 4" SWALE DEPTH TO
CONVEY RUNOFF BETWEEN
INLETS
REVISIONS
DRAWN CHECK SCALE
AS NOTED
PLAN NO.
SHEET
2026 HNT, LLC
C
06/18/2026
25-094
OF 03
Situate In:
Earl Township
Berks County, Pennsylvania
297 SUEDBERG ROAD, SUITE #7, PINE GROVE, PA 17963
(570) 345-8288 FAX: (570) 345-8299
STORM SEWER IMPROVEMENT
PLAN
FOR
HILL ROAD
INSTALLATION DETAIL
PLAN VIEW
SECTION VIEW
ISOMETRIC VIEW
NOTES:
MAXIMUM DRAINAGE AREA = 1/2 ACRE.
INLET PROTECTION SHALL NOT BE REQUIRED FOR INLET TRIBUTARY TO SEDIMENT BASIN OR TRAP. BERMS
SHALL BE REQUIRED FOR ALL INSTALLATIONS.
ROLLED EARTHEN BERM IN ROADWAY SHALL BE MAINTAINED UNTIL ROADWAY IS STONED. ROAD SUBBASE
BERM ON ROADWAY SHALL BE MAINTAINED UNTIL ROADWAY IS PAVED. EARTHEN BERM IN CHANNEL
SHALL BE MAINTAINED UNTIL PERMANENT STABILIZATION IS COMPLETED OR REMAIN PERMANENTLY.
AT A MINIMUM, THE FABRIC SHALL HAVE A MINIMUM GRAB TENSILE STRENGTH OF 120 LBS., A MINIMUM
BURST STRENGTH OF 200 PSI, AND A MINIMUM TRAPEZOIDAL TEAR STRENGTH OF 50 LBS. FILTER BAGS
SHALL BE CAPABLE OF TRAPPING ALL PARTICLES NOT PASSING A NO. 40 SIEVE.
INLET FILTER BAGS SHALL BE INSPECTED ON A WEEKLY BASIS AND AFTER EACH RUNOFF EVENT. BAGS
SHALL BE EMPTIED AND RINSED OR REPLACED WHEN HALF FULL OR WHEN FLOW CAPACITY HAS BEEN
REDUCED SO AS TO CAUSE FLOODING OR BYPASSING OF THE INLET. DAMAGED OR CLOGGED BAGS SHALL
BE REPLACED. A SUPPLY SHALL BE MAINTAINED ON SITE FOR REPLACEMENT OF BAGS. ALL NEEDED
REPAIRS SHALL BE INITIATED IMMEDIATELY AFTER THE INSPECTION. DISPOSE ACCUMULATED SEDIMENT AS
WELL AS ALL USED BAGS ACCORDING TO THE PLAN NOTES.
DO NOT USE ON MAJOR PAVED ROADWAYS WHERE PONDING MAY CAUSE TRAFFIC HAZARDS.
FLOW
Filter Bag Inlet Protection - Type M Inlet
NOT TO SCALE
PADEP STANDARD CONSTRUCTION DETAIL #4-16
W
I
D
T
H
L
E
N
G
T
H
INLET GRATE
I" REBAR FOR BAG
REMOVAL FROM
INLET
EXPANSION RESTRAINT
(1/4" NYLON ROPE)
2" x 2" x 3/4"
RUBBER BLOCK
FLOW
STORM
INLET
2:1 MAX
(TYP.)
EARTHEN BERM TO BE
STABILIZED WITH TEMPORARY
OR PERMANENT VEGETATION
2:1 MAXIMUM
BERM
3:1
6" MINIMUM
HEIGHT
DROP OR
TYPE M
INLET
PLAN VIEW
SECTION A-A
A A
BERM
FLOW
3:13:1
NOTES:
MAXIMUM DRAINAGE AREA =1 ACRE.
INLET PROTECTION SHALL NOT BE REQUIRED FOR INLET TRIBUTARY TO SEDIMENT BASIN OR TRAP. BERMS
SHALL BE REQUIRED FOR ALL INSTALLATIONS NOT LOCATED AT A LOW POINT.
ROLLED EARTHEN BERM IN ROADWAY SHALL BE PROVIDED AND MAINTAINED IMMEDIATELY DOWN GRADIENT
OF THE PROTECTED INLET UNTIL ROADWAY IS STONED. ROAD SUBBASE BERM ON ROADWAY SHALL BE
MAINTAINED UNTIL ROADWAY IS PAVED. EARTHEN BERM IN CHANNEL SHALL BE MAINTAINED UNTIL
PERMANENT STABILIZATION IS COMPLETED OR TO REMAIN PERMANENTLY.
TOP OF BLOCK SHALL BE AT LEAST 6 INCHES BELOW ADJACENT ROADS IF PONDED WATER WOULD POSE
A SAFETY HAZARD TO TRAFFIC.
SEDIMENT SHALL BE REMOVED WHEN IT REACHES HALF THE HEIGHT OF THE STONE. DAMAGED OR
CLOGGED INSTALLATIONS SHALL BE REPAIRED OR REPLACED IMMEDIATELY.
FOR SYSTEMS DISCHARGING TO HQ OR EV SURFACE WATER, A 6 INCH THICK COMPOST LAYER SHALL BE
SECURELY ANCHORED ON OUTSIDE AND OVER TOP OF STONE. COMPOST SHALL MEET THE STANDARDS IN
TABLE 4.2 OF THE PA DEP EROSION CONTROL MANUAL.
Stone And Concrete Block Inlet Protection - Type M Inlet
NOT TO SCALE
PADEP STANDARD CONSTRUCTION DETAIL #4-18
FLOW
6" MINIMUM
M I N I M U M
M I N I M U M
1' MINIMUM
X
X
BERM
STORM
INLET
SECTION VIEW
NOTES:
INLET PROTECTION SHALL NOT BE REQUIRED FOR INLET TRIBUTARY TO SEDIMENT BASIN OR TRAP. BERMS
SHALL BE REQUIRED FOR ALL INSTALLATIONS NOT LOCATED AT A LOW POINT.
ROLLED EARTHEN BERM IN ROADWAY SHALL BE PROVIDED AND MAINTAINED IMMEDIATELY DOWN GRADIENT
OF THE PROTECTED INLET UNTIL ROADWAY IS STONED. ROAD SUBBASE BERM ON ROADWAY SHALL BE
MAINTAINED UNTIL ROADWAY IS PAVED. EARTHEN BERM IN CHANNEL SHALL BE MAINTAINED UNTIL
PERMANENT STABILIZATION IS COMPLETED OR TO REMAIN PERMANENTLY.
STONE INLET PROTECTION AND BERM FOR A TYPE M INLET CAN BE USED IN ONE ACRE MAXIMUM
DRAINAGE AREA WITH 15 IN. OVERFLOW PIPE AND 4 IN. HEAD. A PERFORATED PLATE WELDED TO A
METAL RISER MAY NOT BE SUBSTITUTED FOR THE WIRE MESH. A SLOTTED PLATE WELDED TO THE RISER
MAY BE USED IN CONJUNCTION WITH THE WIRE MESH IF CALCULATIONS ARE PROVIDED TO SHOW
SUFFICIENT CAPACITY OF THE INLET TO ACCEPT THE PEAK RUNOFF FOR A 2-YEAR STORM EVENT FROM
THE TRIBUTARY DRAINAGE AREA. TOP OF PIPE SHALL BE AT LEAST 6 INCHES BELOW ADJACENT
ROADWAY IF PONDED WATER WOULD POSE A SAFETY HAZARD TO TRAFFIC. EARTHEN BERM SHALL BE
ROLLED.
SEDIMENT SHALL BE REMOVED WHEN IT REACHES HALF THE HEIGHT OF THE STONE. DAMAGED OR
CLOGGED INSTALLATIONS SHALL BE REPAIRED OR REPLACED IMMEDIATELY.
FOR SYSTEMS DISCHARGING TO HQ OR EV SURFACE WATER, A 6 IN. THICK COMPOST LAYER SHALL BE
SECURELY ANCHORED ON OUTSIDE AND OVER TOP OF STONE. COMPOST SHALL MEET THE STANDARDS IN
TABLE 4.2 OF THE PA DEP EROSION CONTROL MANUAL.
DO NOT USE ON MAJOR PAVED ROADWAYS WHERE PONDING MAY CAUSE TRAFFIC HAZARDS.
BERM
FLOW
3:13:1
INLET PROTECTION
C ROAD
L
PLAN VIEW
M I N I M U M
Stone Inlet Protection And Berm - Type M Inlet
NOT TO SCALE
PADEP STANDARD CONSTRUCTION DETAIL #4-20
2:1 MAX
6" MINIMUM
HEIGHT
GRATE
15" MINIMUM DIAMETER PIPE
AASHTO #57 STONE
GALVANIZED WIRE MESH,
11 GAUGE OR PLASTIC MESH
(1/4" MAXIMUM OPENING)
EARTHEN BERM STABILIZED
WITH TEMPORARAY OR
PERMANENT VEGETATION
15" MINIMUM DIAMETER PIPE
AASHTO #57 STONE
F
L
O
W
F
L
O
W
DISTURBED AREA
SECTION
PLAN VIEW
DISTURBED AREA
UNDISTURBED AREA
NOTES:
SOCK FABRIC SHALL MEET STANDARDS OF TABLE 4.1 OF THE PA DEP EROSION CONTROL
MANUAL. COMPOST SHALL MEET THE STANDARDS OF TABLE 4.2 OF THE PA DEP EROSION
CONTROL MANUAL.
COMPOST FILTER SOCK SHALL BE PLACED AT EXISTING LEVEL GRADE. BOTH ENDS OF THE
BARRIER SHALL BE EXTENDED AT LEAST 8 FEET UP SLOPE AT 45 DEGREES TO THE MAIN
BARRIER ALIGNMENT. MAXIMUM SLOPE LENGTH ABOVE ANY BARRIER SHALL NOT EXCEED THAT
SPECIFIED FOR THE SIZE OF THE SOCK AND THE SLOPE OF ITS TRIBUTARY AREA.
TRAFFIC SHALL NOT BE PERMITTED TO CROSS COMPOST FILTER SOCKS.
ACCUMULATED SEDIMENT SHALL BE REMOVED WHEN IT REACHES 1/2 THE ABOVE GROUND
HEIGHT OF THE BARRIER AND DISPOSED IN THE MANNER DESCRIBED ELSEWHERE IN THE PLAN.
COMPOST FILTER SOCKS SHALL BE INSPECTED WEEKLY AND AFTER EACH RUNOFF EVENT.
DAMAGED SOCKS SHALL BE REPAIRED ACCORDING TO MANUFACTURER’S SPECIFICATIONS OR
REPLACED WITHIN 24 HOURS OF INSPECTION.
BIODEGRADABLE COMPOST FILTER SOCKS SHALL BE REPLACED AFTER 6 MONTHS;
PHOTODEGRADABLE SOCKS AFTER 1 YEAR. POLYPROPYLENE SOCKS SHALL BE REPLACED
ACCORDING TO MANUFACTURER’S RECOMMENDATIONS.
UPON STABILIZATION OF THE AREA TRIBUTARY TO THE SOCK, STAKES SHALL BE REMOVED. THE
SOCK MAY BE LEFT IN PLACE AND VEGETATED OR REMOVED. IN THE LATTER CASE, THE MESH
SHALL BE CUT OPEN AND THE MULCH SPREAD AS A SOIL SUPPLEMENT.
I N
M I N
PADEP STANDARD CONSTRUCTION DETAIL #4-1
EXISTING CONTOURS
2" x 2" WOODEN STAKES
PLACED 10' O.C.
COMPOST
FILTER
SOCK
2" x 2" WOODEN STAKES
PLACED 10' O.C.
COMPOST
FILTER
SOCK
BLOWN/PLACED
FILTER MEDIA
COMPOST FILTER SOCK
NOT TO SCALE
| S1 |
| S2 |
| S3 |
File details come from the government source that posted it. Updated .