2-Force Main Relocation Plan.pdf
PDF 15 MB Posted
- Attached to
- Sanitary Sewer Force Main Relocation
- Solicitation number
- Not on record
- Issued by
- Berks County, Pennsylvania
About this file
This is a design plan and specification document prepared by Systems Design Engineering, Inc. for Washington Township in Berks County, Pennsylvania, detailing the relocation of an existing 8-inch sanitary sewer force main. The project involves installing approximately 575 linear feet of new PVC C900 force main pipe a minimum of 5 feet away from the existing force main, with connection points established via wet tap tees and isolation valves at both ends. The work includes site access via an access path from Stauffer Road, with a total limit of disturbance of 25,292 square feet (0.581 acres). The project site is located near the future Edison Walk Subdivision development and adjacent to tributaries of Swamp Creek. Sealed bids are due by 12:00 PM on April 23, 2026, with bid opening and consideration of the apparent low bidder occurring at Washington Township's regularly scheduled meeting at 7:00 PM on April 23, 2026, at 120 Barto Road, Barto, PA 19504. Questions must be submitted through PennBid by 4:00 PM on April 19, 2026. No pre-bid meeting is scheduled. The contract term is project-specific with anticipated completion following construction of erosion and sediment control measures and final site stabilization with permanent vegetation.
All bidders must submit bid security equal to 10 percent of the total bid amount in the form of a certified check or surety company bid bond naming Washington Township as payee. Bids may not be withdrawn for 60 days following the bid opening date, and the award must be made within 120 days unless delayed by another government agency's approval, bond sales, or grant awards, with 30-day extensions possible by mutual written consent. All contracts exceeding $10,000 must comply with Executive Order 11246 on Equal Employment Opportunity and Pennsylvania Executive Order 2016-05 regarding nondiscrimination and sexual harassment compliance. The successful bidder will be required to execute the agreement and furnish both a Performance Bond and Payment Bond on forms provided in the contract documents. The project documents, including detailed erosion and sediment control plans, construction sequencing, utility coordination information, and design details, are available at no cost on the PennBid website.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 1-Force Main Relocation Specifications.pdf | ||
| 1-Bid Binder.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UGI UGI
S S
GV
GV
S
BISHOP PINE ROAD
S
EX SAN MH 129
FANGYUAN GE & WENHUAN QIU
INSTR. #2021007219
2213 OLD ROUTE 100
POND
8" SANITARY FORCE MAIN
FM FM FM FM FM
SUGAR MAPLE ROAD
OLD ROUTE 100
S
TA
U
FFE
R R
O A
D
ToA GnA
ToA
GnB
GnB EhB
ASSUMED 50
-F
OOT
FL
OODPLA
IN
ASSU
M
ED
50-FO
O T
FLO
O
D
PLAIN
EDISON VIEW PARTNERS LLC
(FUTURE SITE OF EDISON WALK SUBDIVISION)
INSTR. #2024017251
44 BARTO ROAD
TRIB 01343 OF SWAMP
CREEK (CWF-MF)
TRIB 01342 OF SWAMP
CREEK (CWF-MF)
EdB
GnB
GeB
TR
IB 01341 O
F SW
AM
P
C R
EEK (C
W
F-M F)
FEM
A ZO
N E A
ACCESS PATH FROM
STAUFFER ROAD
WASHINGTON TOWNSHIP, BERKS
PENNSYLVANIA
C
O
PY
RI
G
HT
- S ys te m s D es ig n
En gi ne er in g, In c.
I:\
Pr oj ec ts
\W as hi ng to n
To w ns hi p\
-0
8-
F or ce
M ai n Re lo ca tio n
Sw am p C re ek
\0
- D es ig n
Ph as e\ D ra w in gs
\S he et s\
E&
S D et ai ls.
d w g b y
'G .st ah l'
GRAPHIC SCALE
2000 0
1" = 2000
1000 2000 4000LOCATION
MAP
SITE
WASHINGTON TOWNSHIP
SANITARY SEWER FORCE MAIN RELOCATION
JANUARY 2026
PREPARED BY:
1032 JAMES DR. LEESPORT, PA 19533
PHONE: 610.916.8500 FAX: 610.916.8501
BOYERTOWN, PA 610.369.1319
SCHUYLKILL HAVEN, PA 570.385.5549
SDESYSTEMS DESIGN
ENGINEERING, INC
DRAWING INDEX
NO DESCRIPTION
G001 TITLE SHEET
C101 PROPOSED PLAN II & PROFILE
C501 CONSTRUCTION DETAILS
C601 EROSION AND SEDIMENT CONTROL PLAN I
C602 EROSION AND SEDIMENT CONTROL PLAN II
C603 EROSION AND SEDIMENT CONTROL PLAN III
C604 EROSION AND SEDIMENT CONTROL NOTES
C605 EROSION AND SEDIMENT CONTROL DETAILS
NORTH
SDE
INDEX MAP
SCALE: 1" = 150'
NOTES:
1. SYSTEMS DESIGN ENGINEERING, INC. ("SDE") HAS PERFORMED A DESIGN NOTIFICATION IN COMPLIANCE WITH PENNSYLVANIA ACT 287 OF 1974 AS AMENDED. SDE MAKES NO REPRESENTATION OR GUARANTEE THAT THE INFORMATION RECEIVED IN RESPONSE TO THE NOTIFICATION AND AS DEPICTED ON THESE DRAWINGS IS ACCURATE OR COMPLETE. SDE IS DEPICTING THIS INFORMATION ON THESE DRAWINGS PURSUANT TO THE REQUIREMENTS OF
ACT 287 OF 1974 AS AMENDED.
2. THE LOCATIONS OF UNDERGROUND UTILITIES DEPICTED ON THESE DRAWINGS ARE APPROXIMATE, AND ARE BASED ON ABOVE-GROUND OBSERVATIONS, FACILITY OWNER RESPONSES AND/OR FROM BEST AVAILABLE DRAWING
INFORMATION.
3. EXACT LOCATIONS OF ANY UNDERGROUND UTILITIES CAN ONLY BE DETERMINED BY EXCAVATION AND/OR SUBSURFACE EXPLORATION, WHICH IS NOT PART OF THIS CONTRACT, NOR IS SUCH WORK LISTED UNDER
"RESPONSIBILITIES OF A DESIGNER" AT SECTION 4. OF ACT 287 OF 1974 AS AMENDED.
4. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COMPLY WITH ACT 287 OF 1974 AS AMENDED, AND TO CONTACT THE "ONE-CALL SYSTEM" NOT LESS THAN THREE (3) BUSINESS DAYS NOR MORE THAN TEN (10) BUSINESS
DAYS IN ADVANCE OF EXCAVATION OR DEMOLITION WORK.
5. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WITH THE APPROPRIATE UTILITY THE REMOVAL, ABANDONMENT, RELOCATION, INSTALLATION OR CONNECTION TO ANY PUBLIC UTILITY (GAS, ELECTRIC, TELEPHONE, CABLE TV, FIBER OPTIC COMMUNICATIONS, ETC.)
6. ALL EXISTING UNDERGROUND UTILITY LOCATIONS MUST BE VERIFIED WITH THE APPROPRIATE UTILITY COMPANY
AND/OR CONTRACTOR PRIOR TO ANY EXCAVATION OR DEMOLITION WORK.
7. ANY CONSTRUCTION OR OPERATION UNDERTAKEN ON THIS SITE MUST CONFORM TO ALL LOCAL, STATE AND FEDERAL REGULATIONS, AS WELL AS ANY DEED OR OTHER RESTRICTIONS IN EFFECT AT THE TIME OF OPERATION.
PENNSYLVANIA ONE CALL SYSTEM, INC.
925 IRWIN RUN ROAD
WEST MIFFLIN, PENNSYLVANIA
15122-1078
BEFORE YOU DIG ANYWHERE IN
PENNSYLVANIA CALL 1-800-242-1776
NON-MEMBERS MUST BE CONTACTED DIRECTLY
PA LAW REQUIRES THREE WORKING DAYS
NOTICE TO UTILITIES BEFORE YOU EXCAVATE,
DRILL, BLAST OR DEMOLISH
SERIAL NO. :
20260072204 (01/06/2026)
Know what s below' .
Call before you dig.811
LIST OF PUBLIC UTILITIES
WINDSTREAM
1450 CENTER POINT RD
HITAWATHA, IA 52233
CONTACT: LOCATE DESK PERSONNEL
EMAIL: LOCATE.DESK@WINDSTREAM.COM
PHONE: (800) 289-1901
BUCKEYE PARTNERS
THE BUCKEYE BUILDING
6161 HAMILTON BLVD
ALLENTOWN, PA 18106
CONTACT: BRANDON ALLEN
EMAIL: BALLEN@BUCKEYE.COM
PHONE: (216) 318-2124
PENNSYLVANIA ELECTRIC CO
21 S MAIN ST
AKRON, OH 44308
CONTACT: MELLYSSA ADAMS
EMAIL: MADAMS@FIRSTENERGYCORP.COM
PHONE: (330) 604-4073
COMCAST
1004 CORNERSTONE BLVD
DOWNINGTOWN, PA 19335
CONTACT: JOHN CEDRICK SALVATIERRA
EMAIL: JOHNCEDRICK_SALVATIERRA@COMCAST.COM
PHONE: (267) 271-9781
UGI UTILITIES INC.
225 MORGANTOWN RD.
READING, PA 19611
CONTACT: KURT ZIELASKOWSKI
EMAIL: KZIELASKOWSKI@UGI.COM
PHONE: (610) 736-5571
WASHINGTON TOWNSHIP PERKS COUNTY
567 NIANTIC RD
BARTO, PA 19504
CONTACT: TONY SCHWENK
EMAIL: TSCHWENK@WASHTWPBERKS.ORG
PHONE: (610) 310-6724
WASHINGTON TOWNSHIP PERKS COUNTY
120 BARTO RD
BARTO, PA 19504
CONTACT: BRIAN MOHR
EMAIL: BMOHR@WASHTWPBERKS.ORG
PHONE: (610) 845-7760
TRIB 01343 OF SWAMP CREEK (CWF-MF)
TRIB 01342 OF SWAMP CREEK (CWF-MF)
PROPOSED SANITARY SEWER FORCE MAIN
HORIZONTAL SCALE: 1" = 20'
VERTICAL SCALE: 1" = 4'
4+25
4.
4+50
4.
5+00
2.
5+50
1.
6+00
0.
6+50
9.
7+00
9.
7+50
8.
8+00
8.
8+50
6.
9+00
5.
9+50
3.
9+75
2.
EXISTING GRADE
8 IN C900 SANITARY SEWER FORCE MAIN
8 IN INSERTION VALVE
8 IN WET TAP TEE
8 IN C900 45° ELBOW
8 IN INSERTION VALVE
EXISTING 8" SANITARY
SEWER FORCEMAIN
8 IN C900 45° ELBOW
8 IN C900 45° ELBOW
4' COVER
(MIN)
CLOSE BOTH INSERTION
VALVES AND REMOVE
EXISTING FORCE MAIN
CURB BOX RAISED
18" ABOVE GRADE
CURB BOX RAISED
18" ABOVE GRADE
8 IN CAP
8 IN CAP
8 IN C900 45° ELBOW
8 IN WET TAP TEE
THRUST BLOCK
TBD IF NEEDED
IN FIELD
UGI
UGI UGI UGI UGI UGI UGI UGI UGI UGI UGI UGI UGI UGI UGI
15' 15'
UGI DISTRIBUTION LINE
IP (FND)
N
' 3 8"
W
3.
N44° 12' 22"E 915.14'
FANGYUAN GE & WENHUAN QIU
INSTR. #2021007219
2213 OLD ROUTE 100
POND
6 437 43
8 43 9 44 0 44 1 44
2 44
6 447
449 450 451
8" SANITARY FORCE MAIN
61 62
OPEN SPACE "C"
PROPOSED LOTS OF THE EDISON WALK
SUBDIVISION (NOT APPROVED)
EDISON VIEW PARTNERS, LLC
INSTR. #2024017251
44 BARTO ROAD
P R
O P
O S
E D
LO
TS
O
F TH
E E
D
IS
O N
W A
LK
S
U B
D
IV
IS
IO
N (N
O T A
P P
R O
V E
D
FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM
30' E A
S E
M E
N T
(D B
. 2509, P G
. 0594)
20' S A
N
ITA
R Y
S E
W E
R E
A S
E M
E N
T
TREE COVER
TREE COVER
ToA
GnB
EhB ToA
TRIB 01342 OF SWAMP
CREEK (C
WF-M
F)
ASSUMED 50-FOOT
FLOODPLAIN
ASSUMED 50-FOOT
FLOODPLAIN
441 442
10+00 5+00
6+007+008+009+00 +50
+50 +50+50+50+50
FMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFM
8 IN C900 SANITARY SEWER FORCE MAIN
8 IN INSERTION VALVE & CAP
(LOCATE A MIN 5' FROM JOINTS)
WET TAP TEE
& VALVE
5'
RELOCATE NEW FORCE
MAIN MIN 5' FROM
EXISTING FORCE MAIN
8 IN INSERTION VALVE & CAP
(LOCATE A MIN 5' FROM JOINTS)
WET TAP TEE
& VALVE
5'
RELOCATE NEW FORCE
MAIN MIN 5' FROM
EXISTING FORCE MAIN
CLOSE BOTH INSERTION
VALVES AND REMOVE
EXISTING FORCE MAIN
45° BENDS TO TIE INTO
EXISTING FORCE MAIN
45° BENDS TO TIE INTO
EXISTING FORCE MAIN
FMFMFMFMFMFM
5'
CLOSE BOTH INSERTION
VALVES AND REMOVE
EXISTING FORCE MAIN
5'
ACCESS PATH
UGI
FM
LEGEND
PROPOSED FEATURES
UPRIGHT TEXT PROPOSED FEATURES
EXISTING FEATURES
SLANTED TEXT EXISTING FEATURES
INDEX CONTOURS
INTERMEDIATE CONTOURS
SANITARY FORCE MAIN & MANHOLE
UGI DISTRIBUTION LINE
PROPERTY LINE
LOT LINE
EDGE OF PAVING
ANGLE FITTING & THRUST BLOCK
TEE FITTING & THRUST BLOCK
VALVE
CAP
S
FM SANITARY SEWER (FORCE MAIN)
POND EDGE
TREELINE
X FENCE
EASEMENT LINE
SOILS BOUNDARY
ACCESS PATH
NORTH
SDE
BYREVISIONDATENO.
SITUATE IN
CADD FILE NAMEDRAWN BY CHECKED APPROVED
DRAWING NUMBERSCALEDATE
1032 JAMES DR. LEESPORT, PA 19533
PHONE: 610.916.8500 FAX: 610.916.8501
BOYERTOWN, PA 610.369.1319
SCHUYLKILL HAVEN, PA 570.385.5549
SDESYSTEMS DESIGN
ENGINEERING, INC
C
O
PY
RI
G
HT
- S ys te m s D es ig n
En gi ne er in g, In c.
I:\
Pr oj ec ts
\W as hi ng to n
To w ns hi p\
-0
8-
F or ce
M ai n Re lo ca tio n
Sw am p C re ek
\0
- D es ig n
Ph as e\ D ra w in gs
\S he et s\
Pr op os ed .d w g
- F eb ru ar y 2, 5:
P
M b y 'G
.st ah l'
D-25-0148-0132-C1011/8/2026 1" = 20'
SHEET 2 OF 82 PROPOSED.DWGMJP MJPGTS
WASHINGTON TOWNSHIP BERKS COUNTY COUNTY PA
BARTO, PA 19504
BISHOP PINE ROAD
PROPOSED PLAN & PROFILE
SANITARY SEWER FORCE MAIN RELOCATION
WASHINGTON TOWNSHIP
HORIZONTAL
VERTICAL
20 0 10 20 40
4 0 2 4 8
1" = 20'
1" = 4'
GENERAL PLAN NOTES:
1. THIS PLAN IS FOR RELOCATION OF AN EXISTING FORCE MAIN AWAY FROM AN EXISTING
PROPERTY BOUNDARY AND FENCE LINE. ACCESS TO THE SITE IS FROM THE EXISTING
SANITARY SEWER RIGHT-OF-WAY BEGINNING AT STAUFFER ROAD.
2. EXISTING FEATURES ARE BASED ON THE 'WASHINGTON TOWNSHIP SEWER' PLAN FROM
ASTON SURVEYORS/ENGINEERS, INC., DATED APRIL 8, 2025. TOPOGRAPHIC CONTOURS FOR
THE SITE ARE BASED ON LIDAR DATA.
3. HORIZONTAL DATUM: NAD83 PENNSYLVANIA STATE PLANES, SOUTH ZONE, US FOOT.
4. VERTICAL DATUM: NAVD88.
5. UTILITY INFORMATION FROM SURFACE EVIDENCE OBSERVED IN THE FIELD. ALL UTILITY
LOCATIONS AND DEPTHS SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION.
6. PURSUANT TO THE PA ACT 1999 (2004), NOTIFICATION TO THE “ONE-CALL SYSTEMS” IS
REQUIRED AT LEAST THREE (3) WORKING DAYS PRIOR TO DISTURBING EARTH WITH ANY
TYPE OF POWERED EQUIPMENT. CALL 1-800-242-1776.
7. THIS PARCEL IS LOCATED WITHIN ZONE X, AREA OF MINIMAL FLOOD HAZARD, AS DEPICTED ON FEMA FLOOD INSURANCE RATE MAP (FIRM) 42011C0438G, EFFECTIVE DATE 7/3/2012. THE
PROJECT SITE AND ACCESS PATH IS OUTSIDE OF THE SPECIAL FLOOD HAZARD AREAS.
8. SYSTEMS DESIGN ENGINEERING, INC. (SDEI) DOES NOT GUARANTEE THE ACCURACY OF THE
LOCATIONS OF THE SUBSURFACE UTILITY STRUCTURES SHOWN ON THE PLANS NOR DOES
SDEI GUARANTEE THAT ALL SUBSURFACE STRUCTURES ARE SHOWN.
9. ALL AREAS DISTURBED OUTSIDE THE LIMITS OF CONSTRUCTION SHALL BE REPAIRED OR
REPLACED TO THEIR ORIGINAL CONDITION AS DIRECTED BY THE ENGINEER AT NO
ADDITIONAL COST TO THE OWNER.
10. ALL SANITARY SEWER CONSTRUCTION SHALL BE IN ACCORDANCE WITH WASHINGTON
TOWNSHIP RULES, REGULATIONS AND SPECIFICATIONS.
11. ALL SANITARY SEWER PIPE AND LATERALS SHALL BE PVC C900 PIPE UNLESS OTHERWISE
INDICATED.
12. ALL FORCE MAIN SANITARY SEWER SHALL HAVE A MINIMUM COVER OF FOUR (4) FEET AND
CONSTRUCTED TO PREVENT LOCALIZED HIGH POINTS. AT LOCATIONS WHERE HIGH POINTS
CANNOT BE PREVENTED, AN IN-LINE AIR RELEASE MANHOLE SHALL BE INSTALLED. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR ELIMINATING ALL UNPLANNED LOCALIZED HIGH
POINTS.
13. A 6" WIDE DETECTABLE WARNING TAPE, "CAUTION: BURIED SEWER LINE BELOW" SHALL BE
PROVIDED OVER THE SANITARY SEWER MAIN 12" - 18" BELOW FINISHED GRADE AND AS
DIRECTED BY OWNER/ENGINEER.
14. ALL FORCE MAIN FITTINGS AND APPURTENANCES MUST BE RESTRAINED WITH 2000PV OR
2500 MEGALUG® MECHANICAL JOINT RESTRAINT.
15. INSTALL CURB STOP RAISED 18" ABOVE GRADE FOR ALL VALVES. MARKER POSTS
MUST BE INSTALLED WITHIN 2' OF RAISED CURB BOX.
SE
E
SH
EE
T C
C
SEE SHEET C501 FOR
'BLOW-UP A
CONNECTION DETAIL'
SEE SHEET C501 FOR
'BLOW-UP B
CONNECTION DETAIL'
1 2/3/26 REVISED PER BCCD TECHNICAL DEFICIENCY LETTER DATED 1/21/26 GTS
FMFM
FM FM FM
FMFM
FM FM FM FM
BYREVISIONDATENO.
SITUATE IN
CADD FILE NAMEDRAWN BY CHECKED APPROVED
DRAWING NUMBERSCALEDATE
1032 JAMES DR. LEESPORT, PA 19533
PHONE: 610.916.8500 FAX: 610.916.8501
BOYERTOWN, PA 610.369.1319
SCHUYLKILL HAVEN, PA 570.385.5549
SDESYSTEMS DESIGN
ENGINEERING, INC
C
O
PY
RI
G
HT
- S ys te m s D es ig n
En gi ne er in g, In c.
I:\
Pr oj ec ts
\W as hi ng to n
To w ns hi p\
-0
8-
F or ce
M ai n Re lo ca tio n
Sw am p C re ek
\0
- D es ig n
Ph as e\ D ra w in gs
\S he et s\
D et ai ls.
d w g
- F eb ru ar y 2, 5:
P
M b y 'G
.st ah l'
D-25-0148-0132-C5011/8/2026 1" = 20'
SHEET 3 OF 83 DETAILS.DWGMJP MJPGTS
WASHINGTON TOWNSHIP BERKS COUNTY COUNTY PA
BARTO, PA 19504
BISHOP PINE ROAD
CONSTRUCTION DETAILS
SANITARY SEWER FORCE MAIN RELOCATION
WASHINGTON TOWNSHIP
A
AB
E
NOTES:
1. MECHANICAL JOINT RESTRAINT SHALL REQUIRE CONVENTIONAL TOOLS AND
INSTALLATION PROCEDURES PER AWWA C600, WHILE RETAINING FULL MECHANICAL
JOINT DEFLECTION DURING ASSEMBLY.
2. PROPER ACTUATION OF THE GRIPPING WEDGES SHALL BE ENSURED WITH TORQUE
LIMITING TWIST OFF NUTS.
NOT TO SCALE
2000PV MEGALUG®
MECHANICAL RESTRAINED JOINT
EXCEEDS UNI-B-13 OF 92
MADE IN THE USA
FOR USE ON PVC PIPE
L FM RATED 150 PSI ON DR18
DR25 100 PSI SDR26 160 PSI
DR18 150 PSI SDR21 200 PSI
DR14 200 PSI SDR17 250 PSI
WATER WORKS:
PRESSURE RATINGS FOR ORDINARY
EBAA IRON
U
BLOW-UP A CONNECTION DETAIL
SCALE: 1" = 5'
BLOW-UP B CONNECTION DETAIL
SCALE: 1" = 5'
RESTRAINED CONNECTIONS
TO BE INSTALLED BETWEEN
BENDS
RESTRAINED CONNECTIONS
TO BE INSTALLED BETWEEN
BENDS
WET TAP TEE
ISOLATION VALVE
(LOCATE A MIN 5'
FROM JOINTS)
INSTALL CAP AND
THRUST BLOCK ON
EXISTING FORCE MAIN
VALVE TO BE INSTALLED
WITH WET TAP
8 IN C900 SANITARY SEWER FORCE MAIN 8 IN C900 SANITARY SEWER FORCE MAIN
WET TAP TEE
ISOLATION VALVE
(LOCATE A MIN 5'
FROM JOINTS)
INSTALL CAP AND
THRUST BLOCK ON
EXISTING FORCE MAIN
VALVE TO BE INSTALLED
WITH WET TAP
8 IN SANITARY FORCE MAIN
8 IN SANITARY FORCE MAIN
20' SANITARY SEWER EASEMENT
1 2/3/26 REVISED PER BCCD TECHNICAL DEFICIENCY LETTER DATED 1/21/26 GTS
S
TA
U
FFE
R R
O A
D
20' S A
N
ITA
R Y
S E
W E
R E
A S
E M
E N
T
DENSE VEGETATION
E D
G E
O F P
A V
E M
E N
T
E D
G E
O F P
A V
E M
E N
T
FO
R
M E
R 60' W
ID
E
R A
ILR
O
A D
R /W
ToA GnA
TO
W
N S
H
IP
R /W
LIN
E
30' E A
S E
M E
N T
(D B
. 2509, P G
. 0594) 441
EDISON VIEW PARTNERS LLC
(FUTURE SITE OF EDISON WALK SUBDIVISION)
INSTR. #2024017251
44 BARTO ROAD
SMITH NATHANAEL
DB. 2019, PG. 035323
11 A ESCBACH LANE
4G HOLDINGS LLC
DB. 2019, PG. 005120
15 A ESCBACH LANE
CLEAR AND GRUB SANITARY
SEWER ROW FOR ACCESS TO
SITE. PLACE TRACK
PROTECTION MATS AS NEEDED.
LIMITS OF DISTURBANCE
= 25,292 SF (0.581 AC)
ACCESS PATH
UGI
FM
LEGEND
PROPOSED FEATURES
UPRIGHT TEXT PROPOSED FEATURES
LOD
EXISTING FEATURES
SLANTED TEXT EXISTING FEATURES
INDEX CONTOURS
INTERMEDIATE CONTOURS
SANITARY FORCE MAIN & MANHOLE
UGI DISTRIBUTION LINE
PROPERTY LINE
LOT LINE
EDGE OF PAVING
E&SC FEATURES
LIMIT OF DISTURBANCE
CONCRETE WASHOUT
ANGLE FITTING & THRUST BLOCK
TEE FITTING & THRUST BLOCK
VALVE
CAP
S
FM SANITARY SEWER (FORCE MAIN)
POND EDGE
TREELINE
TRACK MAT PROTECTION
X FENCE
EASEMENT LINE
SOILS BOUNDARY
ACCESS PATH
NORTH
SDE
GRAPHIC SCALE
20 0
1" = 20'
10 20 40
BYREVISIONDATENO.
SITUATE IN
CADD FILE NAMEDRAWN BY CHECKED APPROVED
DRAWING NUMBERSCALEDATE
1032 JAMES DR. LEESPORT, PA 19533
PHONE: 610.916.8500 FAX: 610.916.8501
BOYERTOWN, PA 610.369.1319
SCHUYLKILL HAVEN, PA 570.385.5549
SDESYSTEMS DESIGN
ENGINEERING, INC
C
O
PY
RI
G
HT
- S ys te m s D es ig n
En gi ne er in g, In c.
I:\
Pr oj ec ts
\W as hi ng to n
To w ns hi p\
-0
8-
F or ce
M ai n Re lo ca tio n
Sw am p C re ek
\0
- D es ig n
Ph as e\ D ra w in gs
\S he et s\
E&
S Pl an I.
d w g
- F eb ru ar y
2, 5:
P M b y
'G .st ah l'
D-25-0148-0132-C6011/8/2026 1" = 20'
SHEET 4 OF 84 E&S PLAN I.DWGMJP MJPGTS
WASHINGTON TOWNSHIP BERKS COUNTY PA
BARTO, PA 19504
BISHOP PINE ROAD
EROSION AND SEDIMENT CONTROL PLAN I
SANITARY SEWER FORCE MAIN RELOCATION
WASHINGTON TOWNSHIP
GRAPHIC SCALE
2000 0
1" = 2000
1000 2000 4000LOCATION
MAP
GENERAL E&S NOTES
1. BEFORE INITIATING ANY REVISIONS TO THE EROSION AND SEDIMENT
CONTROL PLAN OR REVISIONS TO OTHER PLANS WHICH MAY AFFECT THE
EFFECTIVENESS OF THE EROSION AND SEDIMENT CONTROL PLAN, THE
OPERATOR MUST RECEIVE APPROVAL OF THE REVISIONS FROM FROM THE
ENGINEER. THE OPERATOR SHALL ASSURE THAT THE EROSION AND
SEDIMENT CONTROL PLAN IS PROPERLY AND COMPLETELY IMPLEMENTED.
IMMEDIATELY UPON DISCOVERING UNFORESEEN CIRCUMSTANCES POSING
THE POTENTIAL FOR ACCELERATED EROSION AND/OR SEDIMENT
POLLUTION, THE OPERATOR SHALL IMPLEMENT APPROPRIATE BEST
MANAGEMENT PRACTICES TO ELIMINATE THE POTENTIAL FOR
ACCELERATED EROSION AND/OR SEDIMENT POLLUTION.
2. A COPY OF THE EROSION AND SEDIMENT CONTROL PLAN (STAMPED,
SIGNED AND DATED BY THE ENGINEER) MUST BE AVAILABLE AT THE
PROJECT SITE AT ALL TIMES. THE OPERATOR SHALL ASSURE THAT AN
EROSION AND SEDIMENT CONTROL PLAN IS BEING IMPLEMENTED AND
MAINTAINED FOR ALL SOIL AND/OR ROCK SPOIL AND BORROW AREAS,
REGARDLESS OF THEIR LOCATIONS.
3. THE PROJECT RECEIVING WATERCOURSE IS TRIB 01342/01343 TO SWAMP
CREEK. THE CHAPTER 93 RECEIVING WATER CLASSIFICATION IS CWF-MF.
THE SITE STORMWATER DISCHARGE IS TRIBUTARY TO WATERS OF THE
COMMONWEALTH; THEREFORE NO OFF-SITE AGREEMENTS ARE REQUIRED.
4. AN AREA SHALL BE CONSIDERED TO HAVE ACHIEVED FINAL STABILIZATION
WHEN IT HAS A MINIMUM UNIFORM 70% PERENNIAL VEGETATIVE COVER OR
OTHER PERMANENT NON-VEGETATIVE COVER WITH A DENSITY SUFFICIENT
TO RESIST ACCELERATED SURFACE EROSION AND SUBSURFACE
CHARACTERISTICS SUFFICIENT TO RESIST SLIDING AND OTHER
MOVEMENTS. CUT AND FILL SLOPES SHALL BE CAPABLE OF RESISTING
FAILURE DUE TO SLUMPING, SLIDING, OR OTHER MOVEMENTS.
5. SEE SHEET C604 FOR SEQUENCE OF CONSTRUCTION.
6. THERE ARE NO ROCK OUTCROPPINGS SINKHOLES, ENVIRONMENTAL
HAZARDS, OR INTRUSION NOR ARE THERE ANY ALLUVIAL SOILS PRESENT IN
THE PROJECT AREA. HYDRIC SOILS ARE PRESENT AT THE SITE.
NOTIFICATION REQUIREMENTS
PRIOR TO COMMENCEMENT OF WORK, THE FOLLOWING NOTICES MUST BE
MADE:
1. BERKS COUNTY CONSERVATION DISTRICT
10 DAYS PRIOR TO START OF CONSTRUCTION
610-372-4657
2. PA FISH & BOAT COMMISSION
10 DAYS PRIOR TO START OF CONSTRUCTION
717-626-0228 (OR VIA FAX: 610-626-0486)
3. PA ONE-CALL
3 DAYS PRIOR TO ANY EXCAVATION
800-242-1776
SHEET NOTES:
1. SEE SHEET C604 & C605 FOR E&SC NOTES AND DETAILS.
2. SEE THIS SHEET FOR USGS LOCATION MAP.
3. SEE SHEET C604 FOR SEQUENCE OF CONSTRUCTION.
SOIL LEGEND & LIMITATIONS
C U
TB
AN
KS
C
AV
E
C O
R R
O
SI
VE
T
O C
O N
C R
ET
E/
ST
EE
L (C
/S
D R
O U
G H
TY
EA
SI
LY
E
R O
D
IB
LE
FL
O
O D
IN
G
D
EP
TH
T
O S
AT
U
R
AT
ED
ZO
N E/
S
EA
SO
N
AL
H
IG
H
W .T
H
YD
R
IC
/H
YD
R
IC
IN
C
LU
SI
O N
S
LO
W
S
TR
EN
G
TH
LA
N
D
SL
ID
E
PR
O
N E
SL
O
W
PE
R C
O
LA
TI
O
N
PI
PI
N G
PO
O
R S
O U
R C
E O
F
TO
PS
O
IL
FR
O
ST
A
C
TI
O N
SH
R
IN
K-
SW
EL
L
PO
TE
N
TI
AL
S
IN
KH
O
LE
PO
N
D
IN
G
W
ET
N
ES
S
SOIL
SYMBOL SOIL NAME
HYD.
SOIL
GRP.
EhB EDGEMONT CHANNERY SANDY LOAM (0-8% SLOPES) A - C X X - - X - - - X X - X - - GnA GLENVILLE SILT LOAM, SOMEWHAT POORLY DRAINED (0-3% SLOPES) C/D - C/S X X - X X - X - X X - X - X GnB GLENVILLE SILT LOAM (3-8% SLOPES) C/D - C/S X X - X X - X - X X - X - - ToA TOWHEE SILT LOAM (0-3% SLOPES) C/D - S X X - X X - X - X X - X - X
NA => NO DATA AVAILABLE
NORTH
SDE
TOTAL SITE LIMITS OF DISTURBANCE
= 25,292 SQ. FT. (0.581 AC)
EXISTING LAND USE
SINGLE FAMILY RESIDENTIAL DWELLINGS,
FIELDS, AND WOODED AREAS
PROPOSED LAND USE
NO CHANGE FROM EXISTING LAND USE
1 2/3/26 REVISED PER BCCD TECHNICAL DEFICIENCY LETTER DATED 1/21/26 GTS
SEE SH
EET 602
SITE
TRIB 01343 OF SWAMP CREEK (CWF-MF)
TRIB 01342 OF SWAMP CREEK (CWF-MF)
GENERAL PLAN NOTES:
1. THIS PLAN IS FOR RELOCATION OF AN EXISTING FORCE MAIN AWAY FROM AN EXISTING
PROPERTY BOUNDARY AND FENCE LINE. ACCESS TO THE SITE IS FROM THE EXISTING
SANITARY SEWER RIGHT-OF-WAY BEGINNING AT STAUFFER ROAD.
2. EXISTING FEATURES ARE BASED ON THE 'WASHINGTON TOWNSHIP SEWER' PLAN FROM
ASTON SURVEYORS/ENGINEERS, INC., DATED APRIL 8, 2025. TOPOGRAPHIC CONTOURS FOR
THE SITE ARE BASED ON LIDAR DATA.
3. HORIZONTAL DATUM: NAD83 PENNSYLVANIA STATE PLANES, SOUTH ZONE, US FOOT.
4. VERTICAL DATUM: NAVD88.
5. UTILITY INFORMATION FROM SURFACE EVIDENCE OBSERVED IN THE FIELD. ALL UTILITY
LOCATIONS AND DEPTHS SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION.
6. PURSUANT TO THE PA ACT 1999 (2004), NOTIFICATION TO THE “ONE-CALL SYSTEMS” IS
REQUIRED AT LEAST THREE (3) WORKING DAYS PRIOR TO DISTURBING EARTH WITH ANY
TYPE OF POWERED EQUIPMENT. CALL 1-800-242-1776.
7. THIS PARCEL IS LOCATED WITHIN ZONE X, AREA OF MINIMAL FLOOD HAZARD, AS DEPICTED ON FEMA FLOOD INSURANCE RATE MAP (FIRM) 42011C0438G, EFFECTIVE DATE 7/3/2012. THE
PROJECT SITE AND ACCESS PATH IS OUTSIDE OF THE SPECIAL FLOOD HAZARD AREAS.
8. SYSTEMS DESIGN ENGINEERING, INC. (SDEI) DOES NOT GUARANTEE THE ACCURACY OF THE
LOCATIONS OF THE SUBSURFACE UTILITY STRUCTURES SHOWN ON THE PLANS NOR DOES
SDEI GUARANTEE THAT ALL SUBSURFACE STRUCTURES ARE SHOWN.
9. ALL AREAS DISTURBED OUTSIDE THE LIMITS OF CONSTRUCTION SHALL BE REPAIRED OR
REPLACED TO THEIR ORIGINAL CONDITION AS DIRECTED BY THE ENGINEER AT NO
ADDITIONAL COST TO THE OWNER.
10. ALL SANITARY SEWER CONSTRUCTION SHALL BE IN ACCORDANCE WITH WASHINGTON
TOWNSHIP RULES, REGULATIONS AND SPECIFICATIONS.
11. ALL SANITARY SEWER PIPE AND LATERALS SHALL BE PVC C900 PIPE UNLESS OTHERWISE
INDICATED.
12. ALL FORCE MAIN SANITARY SEWER SHALL HAVE A MINIMUM COVER OF FOUR (4) FEET AND
CONSTRUCTED TO PREVENT LOCALIZED HIGH POINTS. AT LOCATIONS WHERE HIGH POINTS
CANNOT BE PREVENTED, AN IN-LINE AIR RELEASE MANHOLE SHALL BE INSTALLED. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR ELIMINATING ALL UNPLANNED LOCALIZED HIGH
POINTS.
13. A 6" WIDE DETECTABLE WARNING TAPE, "CAUTION: BURIED SEWER LINE BELOW" SHALL BE
PROVIDED OVER THE SANITARY SEWER MAIN 12" - 18" BELOW FINISHED GRADE AND AS
DIRECTED BY OWNER/ENGINEER.
14. ALL FORCE MAIN FITTINGS AND APPURTENANCES MUST BE RESTRAINED WITH 2000PV OR
2500 MEGALUG® MECHANICAL JOINT RESTRAINT.
15. INSTALL CURB STOP RAISED 18" ABOVE GRADE FOR ALL VALVES. MARKER POSTS
MUST BE INSTALLED WITHIN 2' OF RAISED CURB BOX.
15' 15'
FM
DENSE VEGETATION
DENSE VEGETATION
ToAToAGnA
TRIB 01343 O
F SW
AM
P
CREEK (CW
F-M
F) 48" R
C
P STO
R M
ASSUMED 50-FOOT
FLOODPLAIN
EDISON VIEW PARTNERS LLC
(FUTURE SITE OF EDISON WALK SUBDIVISION)
INSTR. #2024017251
44 BARTO ROAD
LIMITS OF DISTURBANCE
= 25,292 SF (0.581 AC)
ACCESS PATH
UGI
FM
LEGEND
PROPOSED FEATURES
UPRIGHT TEXT PROPOSED FEATURES
LOD
EXISTING FEATURES
SLANTED TEXT EXISTING FEATURES
INDEX CONTOURS
INTERMEDIATE CONTOURS
SANITARY FORCE MAIN & MANHOLE
UGI DISTRIBUTION LINE
PROPERTY LINE
LOT LINE
EDGE OF PAVING
E&SC FEATURES
LIMIT OF DISTURBANCE
CONCRETE WASHOUT
ANGLE FITTING & THRUST BLOCK
TEE FITTING & THRUST BLOCK
VALVE
CAP
S
FM SANITARY SEWER (FORCE MAIN)
POND EDGE
TREELINE
TRACK MAT PROTECTION
X FENCE
EASEMENT LINE
SOILS BOUNDARY
ACCESS PATH
NORTH
SDE
BYREVISIONDATENO.
SITUATE IN
CADD FILE NAMEDRAWN BY CHECKED APPROVED
DRAWING NUMBERSCALEDATE
1032 JAMES DR. LEESPORT, PA 19533
PHONE: 610.916.8500 FAX: 610.916.8501
BOYERTOWN, PA 610.369.1319
SCHUYLKILL HAVEN, PA 570.385.5549
SDESYSTEMS DESIGN
ENGINEERING, INC
C
O
PY
RI
G
HT
- S ys te m s D es ig n
En gi ne er in g, In c.
I:\
Pr oj ec ts
\W as hi ng to n
To w ns hi p\
-0
8-
F or ce
M ai n Re lo ca tio n
Sw am p C re ek
\0
- D es ig n
Ph as e\ D ra w in gs
\S he et s\
E&
S Pl an
II
.d w g
- F eb ru ar y
2, 5:
P M b y
'G .st ah l'
D-25-0148-0132-C6021/8/2026 1" = 20'
SHEET 5 OF 85 E&S PLAN II.DWGMJP MJPGTS
WASHINGTON TOWNSHIP BERKS COUNTY PA
BARTO, PA 19504
BISHOP PINE ROAD
EROSION AND SEDIMENT CONTROL PLAN II
SANITARY SEWER FORCE MAIN RELOCATION
WASHINGTON TOWNSHIP
1 2/3/26 REVISED PER BCCD TECHNICAL DEFICIENCY LETTER DATED 1/21/26 GTS
GRAPHIC SCALE
20 0
1" = 20'
10 20 40
GRAPHIC SCALE
2000 0
1" = 2000
1000 2000 4000LOCATION
MAP
GENERAL E&S NOTES
1. BEFORE INITIATING ANY REVISIONS TO THE EROSION AND SEDIMENT
CONTROL PLAN OR REVISIONS TO OTHER PLANS WHICH MAY AFFECT THE
EFFECTIVENESS OF THE EROSION AND SEDIMENT CONTROL PLAN, THE
OPERATOR MUST RECEIVE APPROVAL OF THE REVISIONS FROM FROM THE
ENGINEER. THE OPERATOR SHALL ASSURE THAT THE EROSION AND
SEDIMENT CONTROL PLAN IS PROPERLY AND COMPLETELY IMPLEMENTED.
IMMEDIATELY UPON DISCOVERING UNFORESEEN CIRCUMSTANCES POSING
THE POTENTIAL FOR ACCELERATED EROSION AND/OR SEDIMENT
POLLUTION, THE OPERATOR SHALL IMPLEMENT APPROPRIATE BEST
MANAGEMENT PRACTICES TO ELIMINATE THE POTENTIAL FOR
ACCELERATED EROSION AND/OR SEDIMENT POLLUTION.
2. A COPY OF THE EROSION AND SEDIMENT CONTROL PLAN (STAMPED,
SIGNED AND DATED BY THE ENGINEER) MUST BE AVAILABLE AT THE
PROJECT SITE AT ALL TIMES. THE OPERATOR SHALL ASSURE THAT AN
EROSION AND SEDIMENT CONTROL PLAN IS BEING IMPLEMENTED AND
MAINTAINED FOR ALL SOIL AND/OR ROCK SPOIL AND BORROW AREAS,
REGARDLESS OF THEIR LOCATIONS.
3. THE PROJECT RECEIVING WATERCOURSE IS TRIB 01342/01343 TO SWAMP
CREEK. THE CHAPTER 93 RECEIVING WATER CLASSIFICATION IS CWF-MF.
THE SITE STORMWATER DISCHARGE IS TRIBUTARY TO WATERS OF THE
COMMONWEALTH; THEREFORE NO OFF-SITE AGREEMENTS ARE REQUIRED.
4. AN AREA SHALL BE CONSIDERED TO HAVE ACHIEVED FINAL STABILIZATION
WHEN IT HAS A MINIMUM UNIFORM 70% PERENNIAL VEGETATIVE COVER OR
OTHER PERMANENT NON-VEGETATIVE COVER WITH A DENSITY SUFFICIENT
TO RESIST ACCELERATED SURFACE EROSION AND SUBSURFACE
CHARACTERISTICS SUFFICIENT TO RESIST SLIDING AND OTHER
MOVEMENTS. CUT AND FILL SLOPES SHALL BE CAPABLE OF RESISTING
FAILURE DUE TO SLUMPING, SLIDING, OR OTHER MOVEMENTS.
5. SEE SHEET C604 FOR SEQUENCE OF CONSTRUCTION.
6. THERE ARE NO ROCK OUTCROPPINGS SINKHOLES, ENVIRONMENTAL
HAZARDS, OR INTRUSION NOR ARE THERE ANY ALLUVIAL SOILS PRESENT IN
THE PROJECT AREA. HYDRIC SOILS ARE PRESENT AT THE SITE.
NOTIFICATION REQUIREMENTS
PRIOR TO COMMENCEMENT OF WORK, THE FOLLOWING NOTICES MUST BE
MADE:
1. BERKS COUNTY CONSERVATION DISTRICT
10 DAYS PRIOR TO START OF CONSTRUCTION
610-372-4657
2. PA FISH & BOAT COMMISSION
10 DAYS PRIOR TO START OF CONSTRUCTION
717-626-0228 (OR VIA FAX: 610-626-0486)
3. PA ONE-CALL
3 DAYS PRIOR TO ANY EXCAVATION
800-242-1776
SHEET NOTES:
1. SEE SHEET C604 & C605 FOR E&SC NOTES AND DETAILS.
2. SEE THIS SHEET FOR USGS LOCATION MAP.
3. SEE SHEET C604 FOR SEQUENCE OF CONSTRUCTION.
SOIL LEGEND & LIMITATIONS
C U
TB
AN
KS
C
AV
E
C O
R R
O
SI
VE
T
O C
O N
C R
ET
E/
ST
EE
L (C
/S
D R
O U
G H
TY
EA
SI
LY
E
R O
D
IB
LE
FL
O
O D
IN
G
D
EP
TH
T
O S
AT
U
R
AT
ED
ZO
N E/
S
EA
SO
N
AL
H
IG
H
W .T
H
YD
R
IC
/H
YD
R
IC
IN
C
LU
SI
O N
S
LO
W
S
TR
EN
G
TH
LA
N
D
SL
ID
E
PR
O
N E
SL
O
W
PE
R C
O
LA
TI
O
N
PI
PI
N G
PO
O
R S
O U
R C
E O
F
TO
PS
O
IL
FR
O
ST
A
C
TI
O N
SH
R
IN
K-
SW
EL
L
PO
TE
N
TI
AL
S
IN
KH
O
LE
PO
N
D
IN
G
W
ET
N
ES
S
SOIL
SYMBOL SOIL NAME
HYD.
SOIL
GRP.
EhB EDGEMONT CHANNERY SANDY LOAM (0-8% SLOPES) A - C X X - - X - - - X X - X - - GnA GLENVILLE SILT LOAM, SOMEWHAT POORLY DRAINED (0-3% SLOPES) C/D - C/S X X - X X - X - X X - X - X GnB GLENVILLE SILT LOAM (3-8% SLOPES) C/D - C/S X X - X X - X - X X - X - - ToA TOWHEE SILT LOAM (0-3% SLOPES) C/D - S X X - X X - X - X X - X - X
NA => NO DATA AVAILABLE
TOTAL SITE LIMITS OF DISTURBANCE
= 25,292 SQ. FT. (0.581 AC)
EXISTING LAND USE
SINGLE FAMILY RESIDENTIAL DWELLINGS,
FIELDS, AND WOODED AREAS
PROPOSED LAND USE
NO CHANGE FROM EXISTING LAND USE
NORTH
SDE
SEE SH
EET 603SE
E
SH
EE
T
SITE
TRIB 01343 OF SWAMP CREEK (CWF-MF)
TRIB 01342 OF SWAMP CREEK (CWF-MF)
GENERAL PLAN NOTES:
1. THIS PLAN IS FOR RELOCATION OF AN EXISTING FORCE MAIN AWAY FROM AN EXISTING
PROPERTY BOUNDARY AND FENCE LINE. ACCESS TO THE SITE IS FROM THE EXISTING
SANITARY SEWER RIGHT-OF-WAY BEGINNING AT STAUFFER ROAD.
2. EXISTING FEATURES ARE BASED ON THE 'WASHINGTON TOWNSHIP SEWER' PLAN FROM
ASTON SURVEYORS/ENGINEERS, INC., DATED APRIL 8, 2025. TOPOGRAPHIC CONTOURS FOR
THE SITE ARE BASED ON LIDAR DATA.
3. HORIZONTAL DATUM: NAD83 PENNSYLVANIA STATE PLANES, SOUTH ZONE, US FOOT.
4. VERTICAL DATUM: NAVD88.
5. UTILITY INFORMATION FROM SURFACE EVIDENCE OBSERVED IN THE FIELD. ALL UTILITY
LOCATIONS AND DEPTHS SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION.
6. PURSUANT TO THE PA ACT 1999 (2004), NOTIFICATION TO THE “ONE-CALL SYSTEMS” IS
REQUIRED AT LEAST THREE (3) WORKING DAYS PRIOR TO DISTURBING EARTH WITH ANY
TYPE OF POWERED EQUIPMENT. CALL 1-800-242-1776.
7. THIS PARCEL IS LOCATED WITHIN ZONE X, AREA OF MINIMAL FLOOD HAZARD, AS DEPICTED ON FEMA FLOOD INSURANCE RATE MAP (FIRM) 42011C0438G, EFFECTIVE DATE 7/3/2012. THE
PROJECT SITE AND ACCESS PATH IS OUTSIDE OF THE SPECIAL FLOOD HAZARD AREAS.
8. SYSTEMS DESIGN ENGINEERING, INC. (SDEI) DOES NOT GUARANTEE THE ACCURACY OF THE
LOCATIONS OF THE SUBSURFACE UTILITY STRUCTURES SHOWN ON THE PLANS NOR DOES
SDEI GUARANTEE THAT ALL SUBSURFACE STRUCTURES ARE SHOWN.
9. ALL AREAS DISTURBED OUTSIDE THE LIMITS OF CONSTRUCTION SHALL BE REPAIRED OR
REPLACED TO THEIR ORIGINAL CONDITION AS DIRECTED BY THE ENGINEER AT NO
ADDITIONAL COST TO THE OWNER.
10. ALL SANITARY SEWER CONSTRUCTION SHALL BE IN ACCORDANCE WITH WASHINGTON
TOWNSHIP RULES, REGULATIONS AND SPECIFICATIONS.
11. ALL SANITARY SEWER PIPE AND LATERALS SHALL BE PVC C900 PIPE UNLESS OTHERWISE
INDICATED.
12. ALL FORCE MAIN SANITARY SEWER SHALL HAVE A MINIMUM COVER OF FOUR (4) FEET AND
CONSTRUCTED TO PREVENT LOCALIZED HIGH POINTS. AT LOCATIONS WHERE HIGH POINTS
CANNOT BE PREVENTED, AN IN-LINE AIR RELEASE MANHOLE SHALL BE INSTALLED. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR ELIMINATING ALL UNPLANNED LOCALIZED HIGH
POINTS.
13. A 6" WIDE DETECTABLE WARNING TAPE, "CAUTION: BURIED SEWER LINE BELOW" SHALL BE
PROVIDED OVER THE SANITARY SEWER MAIN 12" - 18" BELOW FINISHED GRADE AND AS
DIRECTED BY OWNER/ENGINEER.
14. ALL FORCE MAIN FITTINGS AND APPURTENANCES MUST BE RESTRAINED WITH 2000PV OR
2500 MEGALUG® MECHANICAL JOINT RESTRAINT.
15. INSTALL CURB STOP RAISED 18" ABOVE GRADE FOR ALL VALVES. MARKER POSTS
UGI
UGI UGI UGI UGI UGI UGI UGI UGI UGI UGI UGI UGI UGI UGI
15' 15'
UGI DISTRIBUTION LINE
IP (FND)
N
' 3 8"
W
3.
N44° 12' 22"E 915.14'
FANGYUAN GE & WENHUAN QIU
INSTR. #2021007219
2213 OLD ROUTE 100
POND
6 437 43
8 43 9 44 0 44 1 44
2 44
6 447
449 450 451
8" SANITARY FORCE MAIN
61 62
OPEN SPACE "C"
PROPOSED LOTS OF THE EDISON WALK
SUBDIVISION (NOT APPROVED)
EDISON VIEW PARTNERS, LLC
INSTR. #2024017251
44 BARTO ROAD
P R
O P
O S
E D
LO
TS
O
F TH
E E
D
IS
O N
W A
LK
S
U B
D
IV
IS
IO
N (N
O T A
P P
R O
V E
D
FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM
30' E A
S E
M E
N T
(D B
. 2509, P G
. 0594)
20' S A
N
ITA
R Y
S E
W E
R E
A S
E M
E N
T
TREE COVER
TREE COVER
ToA
GnB
EhB ToA
TRIB 01342 OF SWAMP
CREEK (C
WF-M
F)
ASSUMED 50-FOOT
FLOODPLAIN
ASSUMED 50-FOOT
FLOODPLAIN
441 442
FM0+
1+00 2+003+004+005+00
5+
+50 +50+50+50+50
10+00 5+00
6+007+008+009+00 +50
+50 +50+50+50+50
FMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFM
FMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFM
FM
FMFMFMFMFMFMFM
8 IN C900 SANITARY SEWER FORCE MAIN
8 IN INSERTION VALVE & CAP
(LOCATE A MIN 5' FROM JOINTS)
WET TAP TEE
& VALVE
5'
RELOCATE NEW FORCE
MAIN MIN 5' FROM
EXISTING FORCE MAIN
8 IN INSERTION VALVE & CAP
(LOCATE A MIN 5' FROM JOINTS)
WET TAP TEE
& VALVE
5'
RELOCATE NEW FORCE
MAIN MIN 5' FROM
EXISTING FORCE MAIN
CLOSE BOTH INSERTION
VALVES AND REMOVE
EXISTING FORCE MAIN
45° BENDS TO TIE INTO
EXISTING FORCE MAIN
45° BENDS TO TIE INTO
EXISTING FORCE MAIN
FMFMFMFMFMFM
5'
CLOSE BOTH INSERTION
VALVES AND REMOVE
EXISTING FORCE MAIN
5'
LIMITS OF DISTURBANCE
= 25,292 SF (0.581 AC)
ACCESS PATH
PLACE BIODEGRADABLE ECB OVER
DISTURBED AREAS WITHIN THE
50-FOOT ASSUMED FLOODPLAIN
UGI
FM
LEGEND
PROPOSED FEATURES
UPRIGHT TEXT PROPOSED FEATURES
LOD
EXISTING FEATURES
SLANTED TEXT EXISTING FEATURES
INDEX CONTOURS
INTERMEDIATE CONTOURS
SANITARY FORCE MAIN & MANHOLE
UGI DISTRIBUTION LINE
PROPERTY LINE
LOT LINE
EDGE OF PAVING
E&SC FEATURES
LIMIT OF DISTURBANCE
EROSION CONTROL BLANKET
CONCRETE WASHOUT
ANGLE FITTING & THRUST BLOCK
TEE FITTING & THRUST BLOCK
VALVE
CAP
S
FM SANITARY SEWER (FORCE MAIN)
POND EDGE
TREELINE
TRACK MAT PROTECTION
X FENCE
EASEMENT LINE
SOILS BOUNDARY
ACCESS PATH
NORTH
SDE
BYREVISIONDATENO.
SITUATE IN
CADD FILE NAMEDRAWN BY CHECKED APPROVED
DRAWING NUMBERSCALEDATE
1032 JAMES DR. LEESPORT, PA 19533
PHONE: 610.916.8500 FAX: 610.916.8501
BOYERTOWN, PA 610.369.1319
SCHUYLKILL HAVEN, PA 570.385.5549
SDE SYSTEMS DESIGN
ENGINEERING, INC
C
O
PY
RI
G
HT
- S ys te m s D es ig n
En gi ne er in g, In c.
I:\
Pr oj ec ts
\W as hi ng to n
To w ns hi p\
-0
8-
F or ce
M ai n Re lo ca tio n
Sw am p C re ek
\0
- D es ig n
Ph as e\ D ra w in gs
\S he et s\
E&
S Pl an
II
I.d w g
- F eb ru ar y
, 2
2:
P M b y
'G .st ah l'
D-25-0148-0132-C6031/8/2026 1" = 20'
SHEET 6 OF 86 E&S PLAN III.DWGMJP MJPGTS
WASHINGTON TOWNSHIP BERKS COUNTY PA
BARTO, PA 19504
BISHOP PINE ROAD
EROSION AND SEDIMENT CONTROL PLAN III
SANITARY SEWER FORCE MAIN RELOCATION
WASHINGTON TOWNSHIP
GRAPHIC SCALE
20 0
1" = 20'
10 20 40
GRAPHIC SCALE
2000 0
1" = 2000
1000 2000 4000LOCATION
MAP
GENERAL E&S NOTES
1. BEFORE INITIATING ANY REVISIONS TO THE EROSION AND SEDIMENT
CONTROL PLAN OR REVISIONS TO OTHER PLANS WHICH MAY AFFECT THE
EFFECTIVENESS OF THE EROSION AND SEDIMENT CONTROL PLAN, THE
OPERATOR MUST RECEIVE APPROVAL OF THE REVISIONS FROM FROM THE
ENGINEER. THE OPERATOR SHALL ASSURE THAT THE EROSION AND
SEDIMENT CONTROL PLAN IS PROPERLY AND COMPLETELY IMPLEMENTED.
IMMEDIATELY UPON DISCOVERING UNFORESEEN CIRCUMSTANCES POSING
THE POTENTIAL FOR ACCELERATED EROSION AND/OR SEDIMENT
POLLUTION, THE OPERATOR SHALL IMPLEMENT APPROPRIATE BEST
MANAGEMENT PRACTICES TO ELIMINATE THE POTENTIAL FOR
ACCELERATED EROSION AND/OR SEDIMENT POLLUTION.
2. A COPY OF THE EROSION AND SEDIMENT CONTROL PLAN (STAMPED,
SIGNED AND DATED BY THE ENGINEER) MUST BE AVAILABLE AT THE
PROJECT SITE AT ALL TIMES. THE OPERATOR SHALL ASSURE THAT AN
EROSION AND SEDIMENT CONTROL PLAN IS BEING IMPLEMENTED AND
MAINTAINED FOR ALL SOIL AND/OR ROCK SPOIL AND BORROW AREAS,
REGARDLESS OF THEIR LOCATIONS.
3. THE PROJECT RECEIVING WATERCOURSE IS TRIB 01342/01343 TO SWAMP
CREEK. THE CHAPTER 93 RECEIVING WATER CLASSIFICATION IS CWF-MF.
THE SITE STORMWATER DISCHARGE IS TRIBUTARY TO WATERS OF THE
COMMONWEALTH; THEREFORE NO OFF-SITE AGREEMENTS ARE REQUIRED.
4. AN AREA SHALL BE CONSIDERED TO HAVE ACHIEVED FINAL STABILIZATION
WHEN IT HAS A MINIMUM UNIFORM 70% PERENNIAL VEGETATIVE COVER OR
OTHER PERMANENT NON-VEGETATIVE COVER WITH A DENSITY SUFFICIENT
TO RESIST ACCELERATED SURFACE EROSION AND SUBSURFACE
CHARACTERISTICS SUFFICIENT TO RESIST SLIDING AND OTHER
MOVEMENTS. CUT AND FILL SLOPES SHALL BE CAPABLE OF RESISTING
FAILURE DUE TO SLUMPING, SLIDING, OR OTHER MOVEMENTS.
5. SEE SHEET C604 FOR SEQUENCE OF CONSTRUCTION.
6. THERE ARE NO ROCK OUTCROPPINGS SINKHOLES, ENVIRONMENTAL
HAZARDS, OR INTRUSION NOR ARE THERE ANY ALLUVIAL SOILS PRESENT IN
THE PROJECT AREA. HYDRIC SOILS ARE PRESENT AT THE SITE.
NOTIFICATION REQUIREMENTS
PRIOR TO COMMENCEMENT OF WORK, THE FOLLOWING NOTICES MUST BE
MADE:
1. BERKS COUNTY CONSERVATION DISTRICT
10 DAYS PRIOR TO START OF CONSTRUCTION
610-372-4657
2. PA FISH & BOAT COMMISSION
10 DAYS PRIOR TO START OF CONSTRUCTION
717-626-0228 (OR VIA FAX: 610-626-0486)
3. PA ONE-CALL
3 DAYS PRIOR TO ANY EXCAVATION
800-242-1776
SHEET NOTES:
1. SEE SHEET C604 & C605 FOR E&SC NOTES AND DETAILS.
2. SEE THIS SHEET FOR USGS LOCATION MAP.
3. SEE SHEET C604 FOR SEQUENCE OF CONSTRUCTION.
SOIL LEGEND & LIMITATIONS
C U
TB
AN
KS
C
AV
E
C O
R R
O
SI
VE
T
O C
O N
C R
ET
E/
ST
EE
L (C
/S
D R
O U
G H
TY
EA
SI
LY
E
R O
D
IB
LE
FL
O
O D
IN
G
D
EP
TH
T
O S
AT
U
R
AT
ED
ZO
N E/
S
EA
SO
N
AL
H
IG
H
W .T
H
YD
R
IC
/H
YD
R
IC
IN
C
LU
SI
O N
S
LO
W
S
TR
EN
G
TH
LA
N
D
SL
ID
E
PR
O
N E
SL
O
W
PE
R C
O
LA
TI
O
N
PI
PI
N G
PO
O
R S
O U
R C
E O
F
TO
PS
O
IL
FR
O
ST
A
C
TI
O N
SH
R
IN
K-
SW
EL
L
PO
TE
N
TI
AL
S
IN
KH
O
LE
PO
N
D
IN
G
W
ET
N
ES
S
SOIL
SYMBOL SOIL NAME
HYD.
SOIL
GRP.
EhB EDGEMONT CHANNERY SANDY LOAM (0-8% SLOPES) A - C X X - - X - - - X X - X - - GnA GLENVILLE SILT LOAM, SOMEWHAT POORLY DRAINED (0-3% SLOPES) C/D - C/S X X - X X - X - X X - X - X GnB GLENVILLE SILT LOAM (3-8% SLOPES) C/D - C/S X X - X X - X - X X - X - - ToA TOWHEE SILT LOAM (0-3% SLOPES) C/D - S X X - X X - X - X X - X - X
NA => NO DATA AVAILABLE
NORTH
SDE
TOTAL SITE LIMITS OF DISTURBANCE
= 25,292 SQ. FT. (0.581 AC)
EXISTING LAND USE
SINGLE FAMILY RESIDENTIAL DWELLINGS,
FIELDS, AND WOODED AREAS
PROPOSED LAND USE
NO CHANGE FROM EXISTING LAND USE
1 2/3/26 REVISED PER BCCD TECHNICAL DEFICIENCY LETTER DATED 1/21/26 GTS
SE
E
SH
EE
T
SITE
TRIB 01343 OF SWAMP CREEK (CWF-MF)
TRIB 01342 OF SWAMP CREEK (CWF-MF)
GENERAL PLAN NOTES:
1. THIS PLAN IS FOR RELOCATION OF AN EXISTING FORCE MAIN AWAY FROM AN EXISTING
PROPERTY BOUNDARY AND FENCE LINE. ACCESS TO THE SITE IS FROM THE EXISTING
SANITARY SEWER RIGHT-OF-WAY BEGINNING AT STAUFFER ROAD.
2. EXISTING FEATURES ARE BASED ON THE 'WASHINGTON TOWNSHIP SEWER' PLAN FROM
ASTON SURVEYORS/ENGINEERS, INC., DATED APRIL 8, 2025. TOPOGRAPHIC CONTOURS FOR
THE SITE ARE BASED ON LIDAR DATA.
3. HORIZONTAL DATUM: NAD83 PENNSYLVANIA STATE PLANES, SOUTH ZONE, US FOOT.
4. VERTICAL DATUM: NAVD88.
5. UTILITY INFORMATION FROM SURFACE EVIDENCE OBSERVED IN THE FIELD. ALL UTILITY
LOCATIONS AND DEPTHS SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION.
6. PURSUANT TO THE PA ACT 1999 (2004), NOTIFICATION TO THE “ONE-CALL SYSTEMS” IS
REQUIRED AT LEAST THREE (3) WORKING DAYS PRIOR TO DISTURBING EARTH WITH ANY
TYPE OF POWERED EQUIPMENT. CALL 1-800-242-1776.
7. THIS PARCEL IS LOCATED WITHIN ZONE X, AREA OF MINIMAL FLOOD HAZARD, AS DEPICTED ON FEMA FLOOD INSURANCE RATE MAP (FIRM) 42011C0438G, EFFECTIVE DATE 7/3/2012. THE
PROJECT SITE AND ACCESS PATH IS OUTSIDE OF THE SPECIAL FLOOD HAZARD AREAS.
8. SYSTEMS DESIGN ENGINEERING, INC. (SDEI) DOES NOT GUARANTEE THE ACCURACY OF THE
LOCATIONS OF THE SUBSURFACE UTILITY STRUCTURES SHOWN ON THE PLANS NOR DOES
SDEI GUARANTEE THAT ALL SUBSURFACE STRUCTURES ARE SHOWN.
9. ALL AREAS DISTURBED OUTSIDE THE LIMITS OF CONSTRUCTION SHALL BE REPAIRED OR
REPLACED TO THEIR ORIGINAL CONDITION AS DIRECTED BY THE ENGINEER AT NO
ADDITIONAL COST TO THE OWNER.
10. ALL SANITARY SEWER CONSTRUCTION SHALL BE IN ACCORDANCE WITH WASHINGTON
TOWNSHIP RULES, REGULATIONS AND SPECIFICATIONS.
11. ALL SANITARY SEWER PIPE AND LATERALS SHALL BE PVC C900 PIPE UNLESS OTHERWISE
INDICATED.
12. ALL FORCE MAIN SANITARY SEWER SHALL HAVE A MINIMUM COVER OF FOUR (4) FEET AND
CONSTRUCTED TO PREVENT LOCALIZED HIGH POINTS. AT LOCATIONS WHERE HIGH POINTS
CANNOT BE PREVENTED, AN IN-LINE AIR RELEASE MANHOLE SHALL BE INSTALLED. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR ELIMINATING ALL UNPLANNED LOCALIZED HIGH
POINTS.
13. A 6" WIDE DETECTABLE WARNING TAPE, "CAUTION: BURIED SEWER LINE BELOW" SHALL BE
PROVIDED OVER THE SANITARY SEWER MAIN 12" - 18" BELOW FINISHED GRADE AND AS
DIRECTED BY OWNER/ENGINEER.
14. ALL FORCE MAIN FITTINGS AND APPURTENANCES MUST BE RESTRAINED WITH 2000PV OR
2500 MEGALUG® MECHANICAL JOINT RESTRAINT.
15. INSTALL CURB STOP RAISED 18" ABOVE GRADE FOR ALL VALVES. MARKER POSTS
2 2/25/26 REVISED PER BCCD COMMENTS DATED 2/25/26 GTS
BYREVISIONDATENO.
SITUATE IN
CADD FILE NAMEDRAWN BY CHECKED APPROVED
DRAWING NUMBERSCALEDATE
1032 JAMES DR. LEESPORT, PA 19533
PHONE: 610.916.8500 FAX: 610.916.8501
BOYERTOWN, PA 610.369.1319
SCHUYLKILL HAVEN, PA 570.385.5549
SDE SYSTEMS DESIGN
ENGINEERING, INC
C
O
PY
RI
G
HT
- S ys te m s D es ig n
En gi ne er in g, In c.
I:\
Pr oj ec ts
\W as hi ng to n
To w ns hi p\
-0
8-
F or ce
M ai n Re lo ca tio n
Sw am p C re ek
\0
- D es ig n
Ph as e\ D ra w in gs
\S he et s\
E&
S N ot es
.d w g
- F eb ru ar y
, 2
4:
P M b y
'G .st ah l'
D-25-0148-0132-C6041/8/2026 NONE
SHEET 7 OF 87 E&S NOTES.DWGMJP MJPGTS
WASHINGTON TOWNSHIP BERKS COUNTY PA
BARTO, PA 19504
BISHOP PINE ROAD
EROSION AND SEDIMENT CONTROL NOTES
SANITARY SEWER FORCE MAIN RELOCATION
WASHINGTON TOWNSHIP
STANDARD E&S PLAN NOTES
1. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION AND
MAINTENANCE OF ALL EROSION AND SEDIMENT CONTROLS PROPOSED FOR
THIS PROJECT. EROSION AND SEDIMENT CONTROLS SHALL BE
CONSTRUCTED, STABILIZED, AND FUNCTIONAL BEFORE SITE DISTURBANCE
WITHIN THE TRIBUTARY AREAS OF THOSE CONTROLS. THE E&S PLAN,
INCLUDING CONSTRUCTION SEQUENCING AND O&M OF BMPS, MUST BE
IMPLEMENTED AT ALL TIMES.
2. ALL EARTH DISTURBANCES, INCLUDING CLEARING AND GRUBBING AS WELL
AS CUTS AND FILLS SHALL BE DONE IN ACCORDANCE WITH THE APPROVED
EROSION AND SEDIMENT (E&S) PLAN. A COPY OF THE APPROVED DRAWINGS
(STAMPED, SIGNED, AND DATED BY THE REVIEWING AGENCY) MUST BE
AVAILABLE AT THE PROJECT SITE AT ALL TIMES. THE REVIEWING AGENCY
SHALL BE NOTIFIED OF ANY CHANGES TO THE APPROVED PLAN PRIOR TO
IMPLEMENTATION OF THOSE CHANGES. THE REVIEWING AGENCY MAY
REQUIRE A WRITTEN SUBMITTAL OF THOSE CHANGES FOR REVIEW AND
APPROVAL AT ITS DISCRETION.
3. CLEARING, GRUBBING, AND TOPSOIL STRIPPING SHALL BE LIMITED TO
THOSE AREAS DESCRIBED IN EACH STAGE OF THE CONSTRUCTION
SEQUENCE. GENERAL SITE CLEARING, GRUBBING AND TOPSOIL STRIPPING
MAY NOT COMMENCE IN ANY STAGE OR PHASE OF THE PROJECT UNTIL THE
E&S BEST MANAGEMENT PRACTICES (BMPS) SPECIFIED BY THE BMP
SEQUENCE FOR THAT STAGE OR PHASE HAVE BEEN INSTALLED AND ARE
FUNCTIONING AS DESCRIBED IN THIS E&S PLAN.
4. AT LEAST SEVEN (7) DAYS PRIOR TO STARTING ANY EARTH DISTURBANCE
ACTIVITIES, INCLUDING CLEARING AND GRUBBING, THE OWNER AND/OR
OPERATOR SHALL INVITE ALL CONTRACTORS, THE LANDOWNER,
APPROPRIATE MUNICIPAL OFFICIALS, THE E&S PLAN PREPARER, AND A
REPRESENTATIVE FROM THE LOCAL CONSERVATION DISTRICT TO AN
ON-SITE PRECONSTRUCTION MEETING.
5. ALL CONSTRUCTION VEHICLES AND EQUIPMENT ACCESSING OR LEAVING
THE LIMITS OF DISTURBANCE SHALL DO SO VIA PROTECTIVE TRACK MATS
AT THE LOCATION SHOWN ON THE PLANS OR SHALL ACCESS THE LIMITS OF
DISTURBANCE VIA A PAVED SURFACE. ALL CONSTRUCTION VEHICLES SHALL
BE ADEQUATELY CLEANED OF ALL SEDIMENT PRIOR TO LEAVING THE SITE
VIA THE PAVED SURFACE. OTHERWISE, ALL CONSTRUCTION VEHICLES
SHALL LEAVE THE SITE VIA A FLATBED TRAILER AND SHALL BE LOADED
WITHIN THE LIMITS OF DISTURBANCE. THE FLATBED TRAILER SHALL REMAIN
ON THE PAVED SURFACE AT ALL TIMES.
6. AREAS UTILIZED FOR CONSTRUCTION STAGING AND LAY DOWN SHALL BE
STABILIZED AT ALL TIMES DURING CONSTRUCTION.
7. ALL STRIPPING OF VEGETATION, GRADING, FILLING AND EXCAVATION SHALL
BE DONE IN SUCH A WAY AS TO MINIMIZE EROSION. WHENEVER NOTED ON
THE PLANS, NATURAL VEGETATION SHALL BE RETAINED, PROTECTED AND
SUPPLEMENTED. DISTURBED AREAS SHALL BE KEPT TO A PRACTICAL
MINIMUM AND STABILIZED AS QUICKLY AS POSSIBLE IN ACCORDANCE WITH
THE TEMPORARY OR PERMANENT MEASURES OUTLINED IN THE SEEDING
AND MULCHING SCHEDULES.
8. AREAS TO BE FILLED ARE TO BE CLEARED, GRUBBED, AND STRIPPED OF
TOPSOIL TO REMOVE TREES, VEGETATION, ROOTS AND OTHER
OBJECTIONABLE MATERIAL.
9. ALL EXCAVATION FOR UTILITY LINE INSTALLATION SHALL BE LIMITED TO THE
AMOUNT THAT CAN BE EXCAVATED, INSTALLED, BACKFILLED, AND
STABILIZED WITHIN ONE WORKING DAY. ALL EXCAVATED MATERIAL SHALL
BE DEPOSITED ON THE UPSLOPE SIDE OF THE TRENCH.
A. WITHIN PERVIOUS AREAS, IF THERE IS NO OTHER BMP DOWNSLOPE OF
THE DISTURBANCE, ALL DISTURBED TRENCHING AREAS FOR UTILITY
LINE INSTALLATION SHALL BE STABILIZED WITH TEMPORARY OR
PERMANENT SEEDING, MULCH, AND STRAW.
B. WITHIN EXISTING PAVED AREAS, ALL DISTURBED TRENCHING AREAS
SHALL BE STABILIZED BY IMMEDIATELY PLACING 4” MINIMUM DEPTH OF
COMPACTED STONE ON THE BACKFILL UP TO PAVING GRADE OR
TEMPORARILY OR PERMANENTLY PAVING THE TRENCH.
10. CONCRETE WASH WATER SHALL BE HANDLED IN THE MANNER DESCRIBED
ON THE PLAN DRAWINGS. IN NO CASE SHALL CONCRETE WASH WATER BE
ALLOWED TO ENTER ANY STORM SEWER CONVEYANCE SYSTEM OR ENTER
ANY SURFACE WATERS OR GROUNDWATER SYSTEMS.
11. ALL PUMPING OF SEDIMENT LADEN WATER SHALL BE THROUGH A DIRT BAG
FILTRATION DEVICE (IE. PUMPED WATER FILTER BAG), OR EQUIVALENT
SEDIMENT REMOVAL FACILITY, OVER UNDISTURBED VEGETATED AREAS
DOWNSTREAM OF ANY EARTH DISTURBANCE. DISCHARGE POINTS SHALL BE
ESTABLISHED TO PROVIDE FOR MAXIMUM DISTANCE TO ACTIVE
WATERWAYS.
12. SEEPS OR SPRINGS ENCOUNTERED DURING CONSTRUCTION SHALL BE
HANDLED IN ACCORDANCE WITH THE STANDARD AND SPECIFICATION FOR
SUBSURFACE DRAIN OR OTHER APPROVED METHOD.
13. STORMWATER RUNOFF SHALL BE PREVENTED FROM ENTERING STORM
SEWER FACILITIES VIA AN OPEN TRENCH. IF ANY EMERGENCY
REPAIRS/REPLACEMENT OF STORM SEWER FACILITIES MUST OCCUR
RUNOFF SHALL BE PREVENTED FROM ENTERING THE FACILITIES AT THE
POINTS OF REPAIR/REPLACEMENT.
14. IMMEDIATELY UPON DISCOVERING UNFORESEEN CIRCUMSTANCES POSING
THE POTENTIAL FOR ACCELERATED EROSION AND/OR SEDIMENT
POLLUTION, THE CONTRACTOR SHALL IMPLEMENT APPROPRIATE BEST
MANAGEMENT PRACTICES TO MINIMIZE THE POTENTIAL FOR EROSION AND
SEDIMENT POLLUTION AND NOTIFY THE LOCAL CONSERVATION DISTRICT
AND/OR THE REGIONAL OFFICE OF THE DEPARTMENT.
15. UPON REDUCTION, LOSS OR FAILURE OF THE EROSION AND SEDIMENT
CONTROLS, IMMEDIATE ACTION SHALL BE TAKEN TO RESTORE THE
CONTROLS OR PROVIDE AN ALTERNATIVE METHOD OF CONTROL.
16. WHERE EROSION AND SEDIMENT CONTROLS ARE FOUND TO BE
INOPERATIVE OR INEFFECTIVE DURING AN INSPECTION, OR ANY OTHER
TIME, THE CONTRACTOR SHALL IMMEDIATELY CONTACT THE LOCAL
CONSERVATION DISTRICT, BY PHONE OR PERSONAL CONTACT, FOLLOWED
BY THE SUBMISSION OF A WRITTEN REPORT WITHIN FIVE (5) DAYS OF THE
INITIAL CONTACT.
17. IN THE EVENT THAT ARCHEOLOGICAL ARTIFACTS ARE DISCOVERED, THE
GENERAL CONTRACTOR SHALL ENSURE PROTECTION AND REPORT THE
DISCOVERY TO THE OWNER AND THE DIRECTOR OF THE BUREAU OF
HISTORIC PRESERVATION, HISTORICAL AND MUSEUM COMMISSION, P.O.
BOX 1026, HARRISBURG, PA 17120.
18. IN THE EVENT OF SINKHOLE DISCOVERY A PROFESSIONAL GEOLOGIST OR
ENGINEER SHALL BE CONTACTED FOR THEIR PROFESSIONAL OPINION AND
REMEDIAL RECOMMENDATIONS. ADDITIONALLY, THE COUNTY
CONSERVATION DISTRICT SHALL BE MADE AWARE OF THE SINKHOLE
DISCOVERY IMMEDIATELY.
19. SEDIMENT TRACKED ONTO ANY PUBLIC ROADWAY OR SIDEWALK SHALL BE
RETURNED TO THE CONSTRUCTION SITE BY THE END OF EACH WORKDAY.
REMOVAL MAY BE COMPLETED THROUGH THE USE OF MECHANICAL OR
HAND TOOLS, BUT SEDIMENT SHALL NEVER BE WASHED OFF THE ROAD
SURFACE WITH WATER. IN NO CASE SHALL THE SEDIMENT BE WASHED,
SHOVELED, OR SWEPT INTO ANY ROADSIDE DITCH, STORM SEWER, OR
SURFACE WATER.
20. UPON COMPLETION OF ALL EARTH DISTURBANCE ACTIVITIES AND
PERMANENT STABILIZATION OF ALL DISTURBED AREAS, THE OWNER
AND/OR OPERATOR SHALL CONTACT THE LOCAL CONSERVATION DISTRICT
FOR A FINAL INSPECTION PRIOR TO REMOVAL OF TEMPORARY EROSION
AND SEDIMENT CONTROLS.
21. ALL BUILDING MATERIALS AND WASTES SHALL BE REMOVED FROM THE SITE
AND RECYCLED OR DISPOSED OF IN ACCORDANCE WITH THE
DEPARTMENT'S SOLID WASTE MANAGEMENT REGULATIONS AT 25 PA. CODE
260.1 ET SEQ., 271.1, AND 287.1 ET. SEQ. NO BUILDING MATERIALS OR
WASTES OR UNUSED BUILDING MATERIALS SHALL BE BURNED, BURIED,
DUMPED, OR DISCHARGED AT THE SITE.
22. THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ANY MATERIAL
BROUGHT ON SITE IS CLEAN FILL. FORM FP-001 MUST BE RETAINED BY THE
PROPERTY OWNER FOR ANY FILL MATERIAL AFFECTED BY A SPILL OR
RELEASE OF A REGULATED SUBSTANCE BUT QUALIFYING AS CLEAN FILL
DUE TO ANALYTICAL TESTING.
23. BEFORE DISPOSING OF SOIL OR RECEIVING BORROW FOR THE SITE, THE
OPERATOR SHALL ASSURE THAT EACH SPOIL OR BORROW AREA HAS AN
EROSION AND SEDIMENT CONTROL PLAN APPROVED BY THE GOVERNING
CONSERVATION DISTRICT, AND WHICH IS BEING IMPLEMENTED AND
MAINTAINED IN ACCORDANCE WITH CHAPTER 102 REGULATIONS. THE
OPERATOR SHALL NOTIFY THE LOCAL CONSERVATION DISTRICT IN WRITING
OF ALL RECEIVING SPOIL AND BORROW AREAS ONCE THEY HAVE BEEN
IDENTIFIED.
24. FAILURE TO CORRECTLY INSTALL E&S BMPS, FAILURE TO PREVENT
SEDIMENT-LADEN RUNOFF FROM LEAVING THE CONSTRUCTION SITE, OR
FAILURE TO TAKE IMMEDIATE CORRECTIVE ACTION TO RESOLVE FAILURE
OF E&S BMPS MAY RESULT IN ADMINISTRATIVE, CIVIL, AND/OR CRIMINAL
PENALTIES BEING INSTITUTED BY THE PENNSYLVANIA DEPARTMENT OF
ENVIRONMENTAL PROTECTION AS DEFINED IN SECTION 602 OF THE
PENNSYLVANIA CLEAN STREAMS LAW. THE CLEAN STREAMS LAW PROVIDES
FOR UP TO $10,000 PER DAY IN CIVIL PENALTIES, UP TO $10,000 IN SUMMARY
CRIMINAL PENALTIES, AND UP TO $25,000 IN MISDEMEANOR CRIMINAL
PENALTIES FOR EACH VIOLATION.
25. THE CONTRACTOR SHALL PROTECT EXISTING TREES, SHRUBS AND
VEGETATION IN ORDER TO ELIMINATE UNNECESSARY DAMAGE, UNLESS
REMOVAL IS SPECIFICALLY NOTED OR REQUIRED FOR CONSTRUCTION OF
THE PROPOSED E&S BMPS OR PERMANENT SITE IMPROVEMENTS.
26. AFTER FINAL SITE STABILIZATION HAS BEEN ACHIEVED, TEMPORARY E&S
BMPS MUST BE REMOVED OR CONVERTED TO PERMANENT POST
CONSTRUCTION STORMWATER MANAGEMENT BMPS. AREAS DISTURBED
DURING REMOVAL OR CONVERSION OF THE BMPS SHALL BE STABILIZED
IMMEDIATELY. IN ORDER TO ENSURE RAPID REVEGETATION OF DISTURBED
AREAS, SUCH REMOVAL/CONVERSIONS ARE TO BE DONE ONLY DURING THE
GERMINATING SEASON.
27. ALL EARTH DISTURBANCE ACTIVITIES SHALL PROCEED IN ACCORDANCE
WITH THE SEQUENCE PROVIDED ON THE PLAN DRAWINGS. DEVIATION FROM
THAT SEQUENCE MUST BE APPROVED IN WRITING FROM THE LOCAL
CONSERVATION DISTRICT OR BY THE DEPARTMENT PRIOR TO
IMPLEMENTATION.
28. E&S BMPS SHALL REMAIN FUNCTIONAL AS SUCH UNTIL ALL AREAS
TRIBUTARY TO THEM ARE PERMANENTLY STABILIZED OR UNTIL THEY ARE
REPLACED BY ANOTHER BMP APPROVED BY THE LOCAL CONSERVATION
DISTRICT OR THE DEPARTMENT.
29. UPON COMPLETION OF ALL EARTH DISTURBANCE ACTIVITIES AND
PERMANENT STABILIZATION OF ALL DISTURBED AREAS, THE OWNER
AND/OR OPERATOR SHALL CONTACT THE LOCAL CONSERVATION DISTRICT
TO SCHEDULE A FINAL INSPECTION.
30. UNDERGROUND UTILITIES CUTTING THROUGH ANY ACTIVE CHANNEL SHALL
BE BACKFILLED AND THE CHANNEL RESTORED TO ITS ORIGINAL
CROSS-SECTION AND PROTECTIVE LINING. ANY BASE FLOW WITHIN THE
CHANNEL SHALL BE CONVEYED PAST THE WORK AREA IN THE MANNER
DESCRIBED IN THIS PLAN UNTIL SUCH RESTORATION IS COMPLETE.
31. UPON REQUEST, THE APPLICANT OR HIS CONTRACTOR SHALL PROVIDE AN
AS-BUILT (RECORD DRAWING) FOR ANY SEDIMENT BASIN OR TRAP TO THE
MUNICIPAL INSPECTOR, LOCAL CONSERVATION DISTRICT OR THE
DEPARTMENT.
STABILIZATION NOTES
1. AN AREA SHALL BE CONSIDERED TO HAVE ACHIEVED FINAL STABILIZATION
WHEN IT HAS A MINIMUM OF 70% UNIFORM PERENNIAL VEGETATIVE COVER
OR OTHER PERMANENT NON-VEGETATIVE COVER WITH A DENSITY
SUFFICIENT TO RESIST ACCELERATED EROSION AND SUBSURFACE
CHARACTERISTICS SUFFICIENT TO RESIST SLIDING OR OTHER MOVEMENTS.
2. AREAS WHICH ARE TO BE TOPSOILED SHALL BE SCARIFIED TO A MINIMUM
DEPTH OF 3 TO 5 INCHES, OR 6 TO 12 INCHES ON COMPACTED SOILS, PRIOR
TO PLACEMENT OF TOPSOIL. AREAS TO BE VEGETATED SHALL HAVE A
MINIMUM 4 INCHES OF TOPSOIL IN PLACE PRIOR TO SEEDING AND
MULCHING. FILL 3:1 OR GREATER SHALL HAVE A MINIMUM OF 2 INCHES OF
TOPSOIL.
3. ALL GRADED AREAS SHALL BE PERMANENTLY STABILIZED IMMEDIATELY
UPON REACHING FINISHED GRADE. CUT SLOPES IN COMPETENT BEDROCK
AND ROCK FILLS NEED NOT BE VEGETATED.
4. UPON TEMPORARY CESSATION OF AN EARTH DISTURBANCE OR ANY STAGE
OR PHASE OF AN ACTIVITY WHERE A CESSATION OF EARTH DISTURBANCE
ACTIVITIES EXCEED 4 DAYS, THE SITE SHALL BE IMMEDIATELY SEEDED,
MULCHED, OR OTHERWISE PROTECTED FROM ACCELERATED EROSION AND
SEDIMENTATION PENDING FUTURE EARTH DISTURBANCE ACTIVITIES.
5. IMMEDIATELY AFTER EARTH DISTURBANCE ACTIVITIES CEASE IN ANY AREA
OR SUBAREA OF THE PROJECT, THE OPERATOR SHALL STABILIZE ALL
DISTURBED AREAS. DURING NON-GERMINATING MONTHS, MULCH OR
PROTECTIVE BLANKETING SHALL BE APPLIED AS DESCRIBED IN THE PLAN.
AREAS NOT AT FINISHED GRADE, WHICH WILL BE REACTIVATED WITHIN ONE
(1) YEAR, MAY BE STABILIZED IN ACCORDANCE WITH THE TEMPORARY
STABILIZATION SPECIFICATIONS. THOSE AREAS WHICH WILL NOT BE
REACTIVATED WITHIN ONE (1) YEAR SHALL BE STABILIZED IN ACCORDANCE
WITH THE PERMANENT STABILIZATION SPECIFICATIONS.
6. HAY OR STRAW MULCH SHALL BE APPLIED AT RATES OF AT LEAST THREE (3)
TONS PER ACRE. STRAW AND HAY MULCH SHALL BE ANCHORED
IMMEDIATELY AFTER APPLICATION TO PREVENT BEING WINDBLOWN. A
TRACTOR-DRAWN IMPLEMENT MAY BE USED TO “CRIMP” THE STRAW OR
HAY INTO THE SOIL. THIS METHOD IS LIMITED TO SLOPES LESS THAN 3H:1V.
THE MACHINERY SHALL BE OPERATED ALONG THE CONTOUR. (NOTE:
CRIMPING OF HAY OR STRAW BY RUNNING OVER IT WITH TRACKED
MACHINERY IS NOT RECOMMENDED.) STRAW MULCH SHALL BE APPLIED IN
LONG STRANDS, NOT CHOPPED OR FINELY BROKEN.
7. AS DISTURBED AREAS WITHIN A PROJECT APPROACH FINAL GRADE,
PREPARATIONS SHOULD BE MADE FOR SEEDING AND MULCHING TO BEGIN
(I.E. ANTICIPATE THE COMPLETION DATE AND SCHEDULE THE SEEDER). IN
NO CASE SHOULD AN AREA EXCEEDING 15,000 SQUARE FEET, WHICH IS TO
BE STABILIZED BY VEGETATION, REACH FINAL GRADE WITHOUT BEING
SEEDED AND MULCHED. WAITING UNTIL EARTHMOVING IS COMPLETED
BEFORE PREPARING FOR SEEDING AND MULCHING IS NOT ACCEPTABLE.
8. FILL SLOPES SHALL BE SEEDED AND STABILIZED IN 15 FEET TO 25 FEET
VERTICAL INCREMENTS.
9. EROSION CONTROL BLANKETING SHALL BE INSTALLED ON ALL SLOPES
3H:1V OR STEEPER WITHIN FIFTY (50) FEET OF SURFACE WATER AND ON ALL
OTHER DISTURBED AREAS SPECIFIED ON THE PLAN MAPS AND/OR DETAIL
SHEETS. ALTERNATE EROSION CONTROL BLANKETS (MATERIALS AND
INSTALLATION SPECIFICATIONS) MUST BE APPROVED BY THE DESIGNER
AND THE LOCAL CONSERVATION DISTRICT PRIOR TO INSTALLATION.
GRADING REQUIREMENTS
1. ALL FILLS SHALL BE COMPACTED AS REQUIRED TO REDUCE EROSION,
SLIPPAGE, SETTLEMENT, SUBSIDENCE OR OTHER RELATED PROBLEMS. FILL
INTENDED TO SUPPORT BUILDINGS, STRUCTURES AND CONDUITS, ETC.
SHALL BE COMPACTED IN ACCORDANCE WITH LOCAL REQUIREMENTS OR
CODES.
2. ALL EARTHEN FILLS SHALL BE PLACED IN COMPACTED LAYERS NOT TO
EXCEED 9 INCHES IN THICKNESS.
3. FILL MATERIALS SHALL BE FREE OF FROZEN PARTICLES, BRUSH, ROOTS,
SOD, OR OTHER FOREIGN OR OBJECTIONABLE MATERIALS THAT WOULD
INTERFERE WITH OR PREVENT CONSTRUCTION OF SATISFACTORY FILLS.
FROZEN MATERIALS OR SOFT, MUCKY, OR HIGHLY COMPRESSIBLE
MATERIALS SHALL NOT BE INCORPORATED INTO…