2-Exhibit I Plans Specs.pdf
PDF 16 MB Posted
- Solicitation number
- 2025-26
- Issued by
- Barnwell County, South Carolina
About this file
This is a comprehensive set of architectural, engineering, and construction documents for the Old Schoolhouse Park Toilet Facility project for the Town of Hilton Head Island, South Carolina. The project involves constructing a new single-story toilet and storage facility located at 152 William Hilton Parkway, spanning less than 1/4 acre in a Parks & Recreation zone. The design documents were prepared by Hord Coplan Macht, with engineering support from Sturre Engineering (civil), Shearlock Engineering (structural), and Islands Engineering. The project was issued for permitting and construction on August 18, 2025, following previous pre-application and design review submittals.
The facility will be a small masonry building with a standing seam metal roof, fiber cement siding, and a tabby stucco finish, designed to complement the local architectural style. The building includes an accessible unisex toilet room and a storage area, with mechanical, plumbing, and electrical systems sized appropriately for the small structure. The site plan includes provisions for stormwater management, tree and buffer protection, and connects to existing parking and pedestrian infrastructure. The project appears to be funded directly by the Town of Hilton Head Island and is designed to meet 2021 International Building Code requirements, with specific attention to accessibility standards and coastal environmental considerations.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 1-IFB 2025-26 Old Schoolhouse Park Restroom Improvements.pdf | ||
| 3-Exhibit B Bid Form - Old Schoolhouse Restroom.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ABBREVIATIONS
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
R
S
T
V
W
Q
G
T
A.C.
A.D.
A.H.U.
A.T.C.
A.T.
ARCH.
APPROX.
A.O.
AMP., A.
ALUM.
ALT.
A.F.F.
B.T.U.
BRK
BRG.
BOT.
BM.
BLK.
BLDG.
BD.
BAL.
CAB.
CAP.
C/B C.D.
CEM.
CER.
C.F.C.I.
C.F.M.
CIRC.
C.J.
CK'D
CIR
L, CL.
CEIL.
CL.
C.O.
COL.
CONC.
COND.
CONN.
CONST.
CONT.
CONTR. JT.
C.T.
C. TO C.
C
DET.
DIA.
DIFF.
DIM.
DISC.
D.J.
DN.
DR.
D.S.
DWG.(S)
EA.
E.C.
E.F.
EL.
ELEC.
EQUIP.
E.W.C.
EXH.
EXT.
EXIST.
F.A.
F.C.
F.D.
F.E.C.
FIN.
FL.
FT.
FTG.
FFE
F.E.
GA.
GAL.
GALV.
GL.
GND.
GOV'T
GPH
GPM
GR.
GWB
GYP.
H.
H.B.
H.C.
HT.
HM
H.P.
HR.
HTG.
HTR.
H.&V.
HW.
HYD.
I.D.
I.E.
IN.
INCAND.
INSUL.
INT.
J.B.
JCT.
JT.
KVA
KW
LB.,#
LG.
L.P.
LTG.
M.
MAINT.
MAX.
M.D.P.
MECH.
MTL.
MIN.
MISC.
M.O.
MTD.
MTG.
M.V.
M.G.T.
N.A.
N.I.C.
NO.
O.A.
O.C.
O.D.
OH.
OPNG.
OPP.
O.S.B.
PART.
PER.
L, PL.
PLBG.
PLYW'D
PNL.
PRESS.
PSF
PSI
P.T.
PTD.
QTR.
QUAN.
R.
R.A.
RAD.
RD.
REC'D.
RECIRC.
RECP.
REINF.
REQ.
RET.
R.G.
RM.
R.P.M.
T.
TEL.
TEMP.
THK.
THD.
TOIL.
TYP.
VCT
VENT.
VERT.
VTR
W/
WD.
WF
W.G.
WP.
S.A.
SCH.
SECT.
SERV.
SHT.
S.J.
SQ. FT.
ST.
STOR.
STRUCT.
SUSP.
SW.
S.
SIM.
P
O.H.
MAT.
PR.
SPEC.
SLR.
STN.
O.S.D.
O.F.E.
O.F.C.I.
O.F.O.I.
OWNER FURNISHED/
E.I.F.S.
STL.
MFR.
E.J.
M.B. T.B.
S.S. STAINLESS STEEL
BR
CG
C.M.U.
AIR CONDITIONED
AREA DRAIN
AIR HANDLING UN
ABOVE FINISHED FLOOR
ALTERNATE
ALUMINUM
AMPERES
ACCESS OPENING
APPROXIMATELY
ARCHITECTURAL
ASPHALT TILE
ACOUSTIC TILE CEILING
BALANCE
BOARD
BUILDING
BLANK
BEAM
BOTTOM
BUMPER RAIL
BEARING
BRICK
BRITISH THERMAL UNIT
CABINET
CAPACITY
CIRCUIT BREAKER
CEILING DIFFUSER
CEMENT
CERAMIC
CONTRACTOR FURNISHED/
CONTRACTOR INSTALLED
CUBIC FEET/MINUTE
CORNER GUARD
CIRCULATING
CONTROL JOINT
CHECKERED
CIRCUIT
CENTER LINE
CEILING
CLOSET
CONCRETE MASONRY
UNIT
CLEAN OUT
COLUMN
CONCRETE
CONDENSATE
CONNECTION
CONSTRUCTION
CONTINUOUS
CONTRACTION JOINT
CERAMIC TILE
CENTER TO CENTER
DETAIL
DIAMETER
DIFFUSER
DIMENSION
DISCONNECT
DUMMY JOINT
DOWN
DRAIN
DOWN SPOUT
DRAWING(S)
EACH
EMPTY CONDUIT
EXHAUST FAN
EXTERIOR INSULATION
AND FINISHING SYSTEM
ELEVATION
ELECTRIC
EQUIPMENT
ELECTRIC WATER COOLER
EXHAUST
EXPANSION JOINT
EXTERIOR
EXISTING
FIRE ALARM
FLEXIBLE CONNECTION
FLOOR DRAIN
FIRE EXTINGUISHER
FIRE EXTINGUISHER
CABINET
FINISH
FLOOR
FOOT, FEET
FOOTING
ELEVATION
FINISHED FLOOR
GAGE
GALLON
GALVANIZED
GLASS
GROUND
GOVERNMENT
GALLONS/HOUR
GRILLE
GALLONS/MINUTE
GYPSUM WALL BOARD
GYPSUM
HIGH
HOSE BIBB
HOLLOW CORE
HEIGHT
HOLLOW METAL
HORSE POWER
HOUR
HEATING
HEATER
HARDWARE
HYDRANT
INSIDE DIAMETER
INVERT ELEVATION
INCHES
INCANDESCENT
INSULATION
INTERIOR
W.W.F. WELDED WIRE FABRIC
WEATHERPROOF
WATER GAGE
WIDE FLANGE
WOOD
WITH
VENT THRU ROOF
VERTICAL
VENTILATION
NYL COMPOSITE TILE
TYPICAL
TOILET
THRESHOLD
THICKNESS
TEMPERATURE
TELEPHONE
TACK BOARD
TOILET
SWITCH
SUSPENDED
STRUCTURAL
STONE
STORAGE
STEEL
STAINED
SQUARE FEET
SEALER
SPECIFICATIONS
SLIP JOINT
SIMILAR
SHEET
SERVICE
SECTION
SCHEDULE
SUPPLY AIR
SUPPLY
REVOLUTIONS/MINUTE
ROOM
RETURN GRILLE
RETURN
REQUIRED
REINFORCING
RECEPTACLE
RECIRCULATING
RECESSED
ROOF DRAIN
RADIUS
RETURN AIR
RISER
QUANTITY
QUARTER
PAINTED
PRESSURE TREATED
POUNDS/SQUARE INCH
POUNDS/SQUARE FOOT
PRESSURE
PAIR
PANEL
PLYWOOD
PLUMBING
PLATE
PERIMETER
PARTITION
OPEN SIGHT DRAIN
ORIENTED STRANDBOARD
OPPOSITE
OPENING
OVERHEAD
OPPOSITE HAND
OWNER INSTALLED
OWNER FURNISHED/
CONTRACTOR INSTALLED
OUTSIDE DIAMETER
ON CENTER
OUTDOOR AIR
NUMBER
NOT IN CONTRACT
NOT APPLICABLE
MATT GLAZE TILE
MECHANICAL VENTILATION
MOUNTING
MOUNTED
MASONRY OPENING
MISCELLANEOUS
MINIMUM
METAL
MANUFACTURER
MECHANICAL
MAIN DISTRIBUTION PANEL
MARKER BOARD
MAXIMUM
MATERIAL
MAINTENANCE
MOTOR
LIGHTING
LIGHTING PANEL
LONG
POUND
KILOWATT
KILOVOLT AMPERE
JOINT
JUNCTION
JUNCTION BOX
VENTILATING
HEATING AND
EQUIPMENT
OWNER FURNISHED
U.N.O UNLESS NOTED OTHERWISE
MATERIALS LEGEND
BRICK (SEE PLANS AND DETAILS
FOR ALTERNATE CONFIGURATIONS)
CONCRETE
GROUT, MORTAR, SAND
EARTH
COMPACTED SOIL
CMU (SEE PLANS AND DETAILS
FOR ALTERNATE CONFIGURATIONS
ROUGH LUMBER (DISCONTINUOUS
ROUGH LUMBER (CONTINUOUS)
BLOCKING)
FINISH WOOD
ALUMINUM
FERROUS METALS - STEEL
POROUS FILL
GLAZING
GYPSUM WALLBOARD
(LARGE SCALE)
PLYWOOD
RIGID INSULATION
ACOUSTIC TILE
CARPET
BATT INSULATION
PROJECT TEAM
NAME OF PROJECT: TOWN OF HILTON HEAD ISLAND - OLD SCHOOLHOUSE PARK TOILET FACILITY
ADDRESS: 152 WILLIAM HILTON PARKWAY
HILTON HEAD ISLAND, SOUTH CAROLINA, 29926
DISCIPLINE DESIGNER CONTACT PHONE NUMBER
ARCHITECT HORD COPLAN MACHT BARRY H. TAYLOR, AIA, LEED 843-785-2199
STRUCTURAL ENGINEER SHEARLOCK ENGINEERING JAKE EAVENSON, PE 843-473-8767
PLUMBING ENGINEER
MECHANICAL ENGINEER
ELECTRICAL ENGINEER CDDC RYAN M. YOCCO, PE 843-384-4731
OWNER CONTACT: NEAL EIKE, SENIOR PROJECT MANAGER, TOWN OF HILTON HEAD ISLAND
ISLANDS ENGINEERING CARL QUANTE, PE 912-356-9036
ISLANDS ENGINEERING CARL QUANTE, PE 912-356-9036
CIVIL ENGINEER STURRE ENGINEERING NATHAN STURRE, PE 843-929-9432
GENERAL NOTES
1. DO NOT SCALE DRAWINGS. USE DIMENSIONS INDICATED ON DRAWINGS FOR LAYOUT OF WORK.
2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH LISTED BUILDING CODES AND WITH THE MOST
STRINGENT BEING ENFORCED WHERE A CONFLICT ARISES.
3. THE HOURS AND DAYS OF OPERATION SHALL CONFORM TO OWNER'S REQUIREMENTS. VERIFY WITH
OWNER.
4. THE SCHEDULING OF WORK WHICH PRODUCES EXCESSIVE NOISE OR VIBRATION SHALL BE
SHCEDULED WITH THE OWNER'S REPRESENTATIVE. THE OWNER'S REPRESENTATIVE SHALL
DEFINE THE TERM "EXCESSIVE".
5. THE GENERAL CONTRACTOR SHALL NOTIFY THE OWNER AND ARCHITECT IN WRITING
IMMEDIATELY UPON DISCOVERY OF CONDITIONS WHICH ARE IN CONFLICT WITH CONTRACT
DOCUMENTS.
ABBREVIATIONS SYMBOLS
ELEVATION INDICATOR
SECTION MARK
DOOR INDICATOR
EXTERIOR ELEVATION MARK
ELEVATION NUMBER
SHEET NUMBER
SHEET NUMBER
SECTION NUMBER
DIRECTION OF VIEW
NAME
ELEVATION
SIM
A-101
REF
REF
R
E F
R E
FA101
MATERIALS LEGEND
Table 5.6-2. BASIC CODE REVIEW INFORMATION
B. Municipality and/or County Where Project is Located:
C. Jurisdiction for:
(Provide the name of the applicable authority)
1. Site Work:
3. Water:
4. Sewer:
1.2. Is Project in a Flood Plain? Yes No
If building is a mixed occupancy per IBC 302.3, indicate the additional occupancy groups present:
3 Type of Construction (per IBC Chapter 6):
(All site information is required if project affects the site or if site information is necessary for design purposes. All floodplain information is required even if project does not affect site and is not in flood plain.
1.1 Total Area of Project Site (in acres):
5. Zoning: Land Use Zone:
A. Flood Map Information: Community No.: Panel No.:
B. Flood Zone: Base Flood Elevation (BFE):
1.3. Is Project in Wetlands Area? Yes No
(per IBC Chapter 3)
1 Site Development
2 Occupancy
A. Construction Classification:
B. Is the building construction protected or unprotected
C. Is the building construction of combustible or noncombustible materials
A. Occupancy Classification: Group:
B. Additional Occupancy Classification(s) Group:
2. Fire Department: Project in Fire District? Yes No
Table 5.6-6: Fire Resistance Rating of Building Elements
Building Element
Structural Frame Including Columns, Girders and Trusses (per IBC Table 601)
Bearing Walls, Exterior (per IBC Table 601)
C. Building Lowest Floor Elev.:
A. Total Area of Project Site that will be Disturbed/Developed :
Project Designed in Accordance With:
1. International Building Code, 2021 Edition with SC Modifications
2. International Energy Conservation Code, 2009 Edition
3. International Fire Code, 2021 Edition with SC Modifications
4. International Plumbing Code, 2021 Edition with SC Modifications
5. National Electrical Code, NFPA 70, 2020 Edition with SC Modifications
6. ICC/ANSI-A117.1-2017, Accessible and Usable Buildings and Facilities
7. NFPA 101 Life Safety Code, 2012 Edition
N/A
0 0
N/A
Hilton Head Island, SC
Hilton Head Island, SC
Hilton Head Island, SC
N/A
N/A
N/A
N/A
N/A
N/A
Utility & Accessory U
N/A
Unprotected
Combustible
N/A
N/A
Type VB
Hilton Head PSD
Less than 1/4 Acre
PR - Parks & Recreation
X
Hilton Head PSD
Rating As Designed (in hours)
Rating As Required (in hours)
Testing Agency & Design Number (UL, FM, etc.)
Bearing Walls, Interior (per IBC Table 601)
Non-bearing Walls & Partitions, Exterior (per IBC Table 601)
Non-bearing Walls & Partitions, Interior (per IBC Table 601)
Floor Construction, Including Supporting Beams & Joists (per IBC Table 601)
Roof Construction, Including Supporting Beams & Joists (per IBC Table 601)
Fire Walls (per IBC Table 705.4)
Fire Barriers (per IBC Table 706.3.9)
Shaft Enclosures (per IBC Section 707
Fire Partitions (per IBC Section 708
Parks & Recreation
X and X-Shaded 11.0'
TBD' MSL
X
BASIC CODE INFORMATION
VICINITY MAP
LIST OF DRAWINGS
GI-100 GENERAL INFORMATION
S300 FOUNDATION DETAILS
PLUMBING
P1.0 PLUMBING WATER/SEWER PLAN, SCHEDULES
STRUCTURAL
MECHANICAL
M1.0 MECHANICAL HVAC PLAN AND SCHEDULES
ELECTRICAL
E-001 ELECTRICAL NOTES AND SCHEDULES
E-100 ELECTRICAL PLANS AND DETAILS
S100 STRUCTURAL NOTES
GI-110 PROJECT NOTES AND SPECIFICATIONS
S200 FOUNDATION PLAN
AE-101 PLANS
AE-301 SECTIONS / DETAILS
ARCHITECTURAL
C-1 TITLE SHEET
AE-601 DOOR SCHEDULE & DETAILS
AI-201 INTERIOR ELEVATION / FINISH SCHEDULE
C-2 GENERAL NOTES & LEGEND
CIVIL
AE-201 BUILDING ELEVATIONS & SECTIONS
E-200 ELECTRICAL SITE PLAN
C-3 EXISTING CONDITIONS
C-4 DEMOLITION & SWPP PLAN
C-5 SWPPP DETAILS
C-6 SWPPP DETAILS
AS-101 ARCHITECTURAL SITE PLAN
C-7 SITE IMPROVEMENTS PLAN
C-8 GRADING & DRAINAGE PLAN
C-9 UTILITY PLAN
C-10 CIVIL DETAILS
C-11 UTILITY DETAILS
C-12 UTILITY DETAILS
S400 STRUCTURAL DETAILS
T H
E L
IN
E
S H
O W
N A
B O
V E
IS
X
A C
T
LY
O N
E
IN
C H
L O
N G
A T
T H
S
E E
T S
O R
IG
IN
A L
P A
G E
S
IZ
E
Drawing
DATE DESCRIPTION∆
T H
E S
Q U
A R
E S
A B
O V
E A
R E
C O
LO
R
, W
IT
H B
LA
C
K
N
D W
H
IT
E L
E T
T E
R S
, I F
P R
IN
T
E D
C O
R R
E C
T
LY
M C
Y K
ARCHITECT
Project Number:
Drawn By:
Checked By:
© Hord Coplan Macht, Inc.
A
B
C
D
1 2 3 4 5
8/
/2
4:
:0
P
M
Barry H. Taylor, AIA
GI-001
GENERAL
INFORMATION
W ill ia m
H ilt on P ar kw ay
H ilt on H ea d
Is la nd , S ou th
C ar ol in a, O ld
S ch o o lh o u se
P ar k T o ile t F ac ili ty
T ow n of
H ilt on H ea d
Is la nd
CIVIL ENGINEER
1536 Fording Island Road
STRUCTURAL ENGINEER
110 Traders Cross, Second Floor
MECHANICAL AND PLUMBING ENGINEER
110 Holcomb Street
STURRE ENGINEERING
SHEARLOCK ENGINEERING
ISLANDS ENGINEERING
Hilton Head Island, SC 29926
Okatie, SC 29909
Savannah, GA 31406
843.929.9432
843.473.8767
912.356.9035
224253.00 dns bht
Issue Date
AUGUST 18, 2025
ELECTRICAL ENGINEER
P.O. Box 2869
CDDC
Bluffton, SC 29910
843.384.4731
Town of Hilton Head Island
OLD SCHOOLHOUSE PARK
TOILET FACILITY
ARCHITECTURE
LANDSCAPE ARCHITECTURE
PLANNING
INTERIOR DESIGN
10 PALMETTO BUSINESS PARK
HILTON HEAD ISLAND, SC 29928
843.785.2199
HORD COPLAN MACHT
11/15/2024 Town Pre-Application Submittal
3/31/2025 Town DPR Application
8/18/2025 Issued for Permitting/Construction
PROJECT NOTES
CONTRACTOR / SUB-CONTRACTOR NOTES:
1. ALL TRADES SHALL CROSS REFERENCE ALL CONSTRUCTION
DOCUMENTS FOR COORDINATION AND SCOPE OF WORK.
2. ALL CONTRACTORS ARE TO COMPLY WITH ALL LOCAL AND STATE
CODES AND ORDINANCES.
3. REFER TO THE TOWN OF HILTON HEAD ISLAND'S BIDDING
DOCUMENTS FOR RESPONSIBILITY OF FEES / PERMITS ASSOCIATED
WITH TRADES FOR COMPLETION OF WORK OUTLINED.
GENERAL NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH ALL
APPLICABLE LOCAL, STATE AND FEDERAL BUILDING CODES AND /
OR REGULATIONS.
ALL WORK SHALL BE DONE IN A MANNER CONSISTENT WITH THE
HIGHEST STANDARDS OF THE RESPECTIVE TRADES.
THE CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE
HIMSELF WITH THE EXISTING CONDITIONS BEFORE BIDDING /
PRICING.
THE CONTRACTOR SHALL VERIFY ALL FIELD DIMENSIONS BEFORE
PROCEEDING WITH THE WORK. IN THE EVENT OF A DISCREPANCY,
THE CONTRACTOR SHALL NOTIFY THE OWNER IMMEDIATELY.
THE CONTRACTOR SHALL ABIDE BY ALL REQUIREMENTS OF THE
OWNER WITH THE RESPECT TO CONSTRUCTION SCHEDULING,
COORDINATION, TEMPORARY CONSTRUCTION UTILITIES, ETC.
ALL MATERIALS, PRODUCTS AND UNITS SHALL BE INSTALLED PER
MANUFACTURER'S RECOMMENDATIONS AND INSTRUCTIONS.
OWNER SHALL BE NOTIFIED IMMEDIATELY OF ANY
DISCREPANCIES.
INSTALLATION OF ALL MATERIALS AND/OR UNITS TO BE SELECTED
OR SUPPLIED BY OWNER SHALL BE SCHEDULED AND
COORDINATED BY THE CONTRACTOR TO MAINTAIN THE
CONSTRUCTION SCHEDULE PRIOR TO THE COMMENCEMENT OF
THE WORK.
ALL FINISH PAINT SHALL BE APPLIED OVER A COMPATIBLE
FACTORY OR FIELD APPLIED PRIMER.
THE CONTRACTOR SHALL PROTECT ALL EXISTING AND ADJACENT
AREAS AT ALL TIMES DURING CONSTRUCTION. ANY AREA
DAMAGED OR AFFECTED BY CONSTRUCTION SHALL BE PATCHED,
REPAIRED, OR REPLACED AS REQUIRED TO MATCH EXISTING OR
ADJACENT AREAS AT THE CONTRACTOR'S EXPENSE.
THE CONTRACTOR SHALL NOT DISRUPT THE BUILDING OR
OPERATION WITHOUT PRIOR SCHEDULING AND APPROVAL FROM
THE OWNER'S REPRESENTATIVE.
THE ARCHITECT ASSUMES NO RESPONSIBILITY FOR ANY
DEVIATION FROM THE FINAL CONSTRUCTION DOCUMENTS, NO
MATTER WHAT THE CAUSE, UNLESS A WRITTEN DIRECTIVE IS
GIVEN BY THE ARCHITECT.
IF CONFLICT OCCURS ON THESE CONSTRUCTION DOCUMENTS,
THE CONTRACTOR SHALL PRICE THE HIGHER QUALITY AND / OR
QUANTITY. THE CONTRACTOR SHALL ALSO CONTACT THE
OWNER'S REPRESENTATIVE FOR CLARIFICATION BEFORE
SUBMITTING HIS BID.
ALL WORK THAT IS EITHER IMPLIED OR REASONABLY INFERRED BY
THE CONTRACT DOCUMENTS SHALL BE THE RESPONSIBILITY OF
THE CONTRACTOR.
ALL WORK PERFORMED SHALL INCLUDE ALL APPURTENANCES
AND APPARATUS NORMALLY DEEMED TO BE PART OF A COMPLETE
PACKAGE WITHIN THE DEFINITION OF NORMAL INDUSTRY
STANDARDS.
ALL PLAN DIMENSIONS FOR NEW WORK ARE TO FACE OF STUDS
UNLESS NOTED OTHERWISE. ALL PLAN DIMENSIONS TO EXISTING
CONSTRUCTION ARE TO FACE OF GYPSUM BOARD UNLESS NOTED
OTHERWISE. ALL FINAL DIMENSIONS AND LAYOUT SHALL BE
VERIFIED WITH AND APPROVED BY THE OWNER AS REQUIRED
BEFORE PROCEEDING WITH THE WORK.
ALL PERMITS, INSPECTIONS AND APPROVALS SHALL BE SECURED
BY THE CONTRACTOR IN COORDINATION WITH THE OWNER.
THE CONTRACTOR SHALL PROVIDE ALL MISCELLANEOUS
BLOCKING AND BRACING AS REQUIRED.
NEITHER THE ARCHITECT NOR THE OWNER ASSUMES
RESPONSIBILITY FOR CONSTRUCTION MEANS AND METHODS,
MATERIALS, TECHNIQUES, PROCEDURES, SEQUENCES OR
SCHEDULING IN CONNECTION WITH THE WORK.
IN THE EVENT OF NOTE DIRECTION OR MATERIAL SPECIFICATION
CONFLICT IN THESE DOCUMENTS CONTACT THE OWNER'S
REPRESENTATIVE.
THE CONTRACTOR SHALL REMOVE ALL RUBBISH AND WASTE
MATERIAL ON A DAILY BASIS AND KEEP THE JOB SITE AND ALL
EGRESS EXIT PATHWAYS BROOM CLEAN AT ALL TIMES. ALL
WASTE MATERIAL SHALL BE DISPOSED OF PROPERLY.
GENERAL RESPONSIBILITY NOTES:
1.
2.
3.
4.
ALL CONTRACTORS ARE RESPONSIBILE TO REVIEW ALL NOTES ON
THIS SHEET. THESE ARE STANDARD MATERIAL AND METHODS FOR
CONSTRUCTION.
GENERAL CONTRACTOR IS RESPONSIBLE FOR FINAL GENERAL
CLEANING PRIOR TO TURN OVER TO OWNER'S REPRESENTATIVE.
GENERAL CONTRACTOR IS TO CONTACT OWNER'S
REPRESENTATIVE FOR FINAL INSPECTION.
ALL CONTRACTORS ARE TO PROTECT ALL FINISH MATERIALS,
WHEN APPLYING PAINT OR ANY MATERIAL. GENERAL
CONTRACTOR IS RESPONSIBLE FOR ALL SUBS AND SUB
CONTRACTORS ARE RESPONSIBLE FOR ALL CLEANUP COSTS TO
REPAIR MATERIAL TO ORIGINAL CONDITION.
GENERAL CONTRACTOR IS RESPONSIBLE FOR CONTACTING
OWNER'S REPRESENTATIVE FOR FINAL WALK THRU, PUNCH LIST
AND COMPLIANCE VERIFICATION PRIOR TO OWNER OCCUPANY
AND FINAL TURNOVER.
FINISH NOTES:
1. INTERIOR WALL AND CEILING FINISHES SHALL COMPLY WITH IBC
803.9 INTERIOR FINISH REQUIREMENTS BASED ON GROUP.
INTERIOR WALL AND CEILING FINISH SHALL HAVE A FLAME SPREAD
INDEX NOT GREATER THAN THAT SPECIFIED IN TABLE 803.11 FOR
THE GROUP AND LOCATION DESIGNATED. INTERIOR WALL AND
CEILING FINISH MATERIALS TESTED IN ACCORDANCE WITH NFPA
286 AND MEETING THE ACCEPTANCE CRITERIA OF SECTION
803.1.2.1 SHALL BE PERMITTED TO BE USED WHERE A CLASS A
CLASSIFICATION IN ACCORDANCE WITH ASTM E 84 IS REQUIRED.
HARDWARE NOTES:
1.
2.
3.
4.
5.
6.
HARDWARE LOCK KEYING - HARDWARE SUPPLIER TO PROVIDE
LOCK SCHEDULE KEY DIAGRAM AND HAVE A REPRESENTATIVE GO
OVER BUILDING KEYING DIRECTLY WITH OWNER'S
REPRESENTATIVE. KEYS TO BE HANDED DIRECTLY TO OWNER'S
REPRESENTATIVE.
FINAL CORES TO BE COORDINATED WITH OWNER'S
REPRESENTATIVE.
ALL HARDWARE TO BE AMERICAN WITH DISABILITIES ACT (ADA)
COMPLIANT.
HARDWARE SUPPLIER TO PROVIDE DOOR STOPS AT ALL DOORS
(I.E. WALL STOP, HINGE STOP, FLOOR STOP, OR OVERHEAD).
THESE STOPS TO BE PROVIDED IN THIS ORDER WITH WALL STOPS
AS THE PREFERRED APPLICATION.
AT NEW DOORS, DOOR HARDWARE MANUFACTURER AND TRIM IS
TO MATCH OWNER SELECTED MANUFACTURER, TRIM STYLE, AND
FINISH.
HARDWARE FOR DOORS THAT ARE TO RECEIVE PASSAGE,
STORAGE, OR PRIVACY SETS IS TO BE DETERMINED BY THE
OWNER'S REPRESENTATIVE.
GENERAL REQUIREMENTS:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
THE CONSTRUCTION DOCUMENTS ARE INTENDED TO GIVE A
DESCRIPTION OF THE WORK. NO DEVIATION FROM THE
CONSTRUCTION DOCUMENTS SHALL BE MADE WITHOUT THE
WRITTEN CONSENT OF THE ARCHITECT. THE CONTRACTOR IS TO
CLARIFY ANY DISCREPENCIES WITH THE OWNER PRIOR TO
BEGINNING WORK. THE CONTRACTOR SHALL VISIT THE SITE TO
VERIFY EXISTING CONDITIONS AND ACCESS TO THE WORK AREA.
THE CONTRACTOR HAS THE SOLE RESPONSIBILITY FOR AND SHALL
HAVE CONTROL OF CONSTRUCTION MEANS, METHODS,
TECHNIQUES, SEQUENCES, AND SAFETY PRECAUTIONS AND
PROCEDURES USED TO CONSTRUCT THE WORK.
THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS
(INCLUDING TAXES) AND EQUIPMENT AS NECESSARY TO
COMPLETE THE WORK. PERMITS SHALL BE OBTAINED AND PAID
FOR AS DIRECTED BY THE OWNER.
THE CONTRACTOR SHALL FURNISH TEMPORARY BRACING OF ALL
BUILDING ELEMENTS DURING CONSTRUCTION. TEMPORARY
BRACING SYSTEMS SHALL BE DESIGNED TO WITHSTAND CODE
DESIGN LOADS. CONTRACTOR SHALL RETAIN SERVICES OF A
PROFESSIONAL ENGINEER TO DESIGN AND SUPERVISE BRACING
INSTALLATION IF THEY DO NOT HAVE THE EXPERTISE REQUIRED.
ALL APPLICABLE FEDERAL, STATE, AND LOCAL CODES,
ORDINANCES AND REGULATIONS, INCLUDING THE REQUIREMENTS
OF THE AMERICANS WITH DISABILITIES ACT (ADA) ARE MADE PART
OF THESE SPECIFICATIONS AND SHALL BE COMPLED WITH BY THE
CONTRACTOR.
IN AS MUCH AS THE SPECIFICATIONS ARE BRIEF, THE
CONTRACTOR SHALL PROVIDE WORKMANSHIP THAT IS NEAT,
SECURE, AND OF THE BEST QUALITY WITH THE BEST POSSIBLE
APPEARANCE AND UTILITY. FAULTY WORK SHALL BE REPAIRED OR
REPLACED AT NO COST TO THE OWNER. INDUSTRY STANDARDS
SHALL BE USED AS THE GUIDE FOR QUALITY OF MATERIALS AND
WORKMANSHIP.
REFERENCE TO MATERIALS OR SYSTEMS HEREIN BY NAME, MAKE
OR CATALOG NUMBER IS INTENDED TO ESTABLISH A QUALITY
STANDARD, AND TO NOT LIMIT COMPETITION. THE WORDS "OR
APPROVED EQUAL" ARE IMPLIED FOLLOWING EACH BRAND NAME/
MODEL NUMBER UNLESS STATED OTHERWISE. "OR APPROVED
EQUAL" MATERIALS SHALL BE APPROVED BY THE OWNER.
THE CONTRACTOR SHALL OBTAIN THE OWNER'S APPROVAL OF THE
CONSTRUCTION SCHEDULE PRIOR TO PROCEEDING WITH THE
WORK.
THE CONTRACTOR SHALL PROVIDE COMPETENT ON-SITE
SUPERVISION, AND KEEP BROOM CLEAN THE CONSTRUCTION SITE.
THE CONTRACTOR SHALL PROVIDE DUMPSTERS FOR REFUSE
DISPOSAL.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY ON
SITE AND PROTECTION OF SITE PER LOCAL, STATE AND FEDERAL
REQUIREMENTS.
THE CONTRACTOR SHALL GUARANTEE ALL WORKMANSHIP AND
MATERIALS FOR A PERIOD OF ONE YEAR AFTER SUBSTANTIAL
COMPLETION OF THE PROJECT. FURNISH MANUFACTURER'S
WRITTEN WARRANTIES TO OWNER FOR SPECIFIED EQUIPMENT
STATING EFFECTIVE WARRANTY DATE.
SEALANTS:
CAULK AROUND ALL DOORS AND VENT OPENINGS, WHERE DIFFERENT
MATERIALS MEET, JOINTS, COUNTERTOPS, DOOR FRAMES, ETC. AND AS
REQUIRED FOR A WATERTIGHT CONNECTION. CAULK TO BE INSTALLED
AFTER FINISH IS APPLIED TO SURFACES PER MANUFACTURER'S
REQUIREMENTS.
DOORS AND FRAMES:
1.
2.
3.
4.
5.
6.
7.
8.
FURNISH AND INSTALL ALL DOOR ASSEMBLIES AS INDICATED ON
THE DRAWINGS ALONG WITH ALL HARDWARE INDICATED AND THAT
MAY BE REQUIRED FOR A COMPLETE INSTALLATION.
ALL DOORS SHALL OPERATE SMOOTHLY WITHOUT BIND AND BE
INSTALLED PLUMB AND TRUE.
ALL HARDWARE SHALL FIT PROPERLY AND BE ADJUSTED AS
REQUIRED FOR SMOOTH OPERATION.
ALL LOCKSETS SHALL BE LEVER TYPE AS REQUIRED TO MEET
REQUIREMENTS OF ADA AND ANSI A117.1.
ALL OTHER HARDWARE SHALL MEET REQUIREMENTS OF ADA AND
ANSI A117.1.
ALL EXIT DOORS SHALL BE EQUIPED WITH LEVER TYPE HARDWARE
OPERABLE FROM THE INSIDE WITHOUT THE USE OF A LATCH, KEY
OR BOLT.
CONTRACTOR TO COORDINATE KEYING SCHEDULE WITH OWNER'S
REPRESENTATIVE.
ALL DOOR HARDWARE TO BE APPROVED BY OWNER'S
REPRESENTATIVE FOR THE TYPE AND FINISH EXCEPT AS
REQUIRED TO MEET ADA AND ANSI A117.1 REQUIREMENTS.
GYPSUM BOARD
FINISHES - GENERAL:
1.
2.
3.
4.
PROVIDE AND INSTALL ALL FINISHES AS INDICATED ON THE
DRAWINGS.
INSTALL ALL MATERIALS PER MANUFACTURER'S
RECOMMENDATIONS AND SPECIFICATIONS.
"FINISH" INSTALLER SHALL INSPECT SUBSURFACE AND PREPARE
AS PER MANUFACTURER'S SPECIFICATION PRIOR TO INSTALLATION
OF PRODUCT.
ALL FINISHES SHALL MEET ALL CODE REQUIREMENTS AND
REGULATIONS INCLUDING FLAME SPREAD AND SMOKE
DEVELOPMENT.
PAINTING:
1.
2.
3.
4.
5.
6.
FURNISH ALL LABOR, MATERIALS, TOOLS, EQUIPMENT AND
SCAFFOLDING REQUIRED FOR COMPLETING SURFACE
PREPARATION, PAINTING, FINISHING AND RELATED ITEMS.
EXCESS MATERIALS, CONTAINERS, AND OTHER ITEMS NECESSARY
FOR THE COMPLETION OF THE WORK MUST BE DISPOSED OF IN A
MANNER THAT MEETS OR EXCEEDS THE STRICTEST LAWS
GOVERNING THE PROJECT'S MUNICIPALITY AND/OR STATE. THE
PAINTING CONTRACTOR IS RESPONSIBLE FOR COMPLETE
ADHERENCE TO ALL DISPOSAL REGULATIONS.
PAINT ALL EXPOSED MISCELLANEOUS ITEMS, FINISHED OR
UNFINISHED (EXCLUDING HVAC RETURN AIR GRILLES, CONDUIT,
ETC.) TO MATCH ADJOINING WALL SURFACES.
VERIFY THAT PAINT IS COMPATIBLE WITH PRIMER OF SHOP PRIMED
SURFACES. NOTIFY OWNER'S REPRESENTATIVE IF THERE ARE ANY
COMPATIBILITY ISSUES.
CONTRACTOR SHALL KEEP EMPTY CONTAINERS ON THE PROJECT
SITE UNTILL ALL PRODUCTS ARE VERIFIED AS TO COLOR AND/OR
SHEEN. THE CONTRACTOR SHALL LEAVE THE OWNER ALL OPENED
PAINT CONTAINERS.
PAINT FOR INTERIOR ITEMS:
a. CONCRETE FLOOR SEALER SUBSTRATES, TRAFFIC
SURFACES
i. SHERWIN-WILLIAMS H&C LOW VOC CONCRETE
SEALER CLEAR GLOSS SOLVENT-BASED
1. FIRST COAT: INTERIOR/EXTERIOR CLEAR
CONCRETE FLOOR SEALER
2. TOP COAT: INTERIOR/EXTERIOR CLEAR
CONCRETE FLOOR SEALER
b. CONCRETE MASONRY UNITS SUBSTRATES:
i. LATEX OVER BLOCK FILLER SYSTEM:
1. BLOCK FILLER. LATEX BLOCK FILLER
2. INTERMEDIATE COAT: LATEX, MATCHING
TOP COAT
3. TOPCOAT: INSTITUTIONAL LOW-ODOR/
VOC LATEX SEMI-GLOSS
7.
8.
9.
10.
11.
12.
13.
c. DRYWALL FINISH: SEMI-GLOSS
i. 1 COAT S-W PREPRITE 200 LATEX PRIMER B28
SERIES (4 MILS WET, 1.2 MILS DRY)
ii. 2 COATS S-W PROMAR 200 INTERIOR LATEX
SEMI-GLOSS B31 SERIES (4 MILS WET, 1.3 MILS
DRY/COAT)
d. NEW WOOD, STAINED:
i. 1 COAT S-W WOOD CLASSICS INTERIOR OIL, STAIN
A49 SERIES
ii. 1 COAT S-W WOOD CLASSICS POLYURETHANE
GLOSS VARNISH A67V1
iii. 1 COAT S-W CLASSIC POLYURETHANE SATIN
VARNISH A67 SERIES (4 MILS WET, 1.4 MILS DRY /
COAT)
e. NEW WOOD, PAINTED:
i. 1 COAT S-W PREPRITE CLASSIC INTERIOR LATEX
PRIMER B28 SERIES (4 MILS WET, 1.6 MILS DRY)
ii. 2 COATS S-W DURATION HOME LATEX SATIN B97
SERIES (4 MILS WET, 1.5 MILS DRY / COAT)
f. FERROUS METAL (PRIMED, BRUSH/ROLLER) DOORS, FRAMES, HANDRAILS, MISC METALS, ETC.: ACRYLIC
i. 1 COAT S-W DTM ACRYLIC SEMI-GLOSS PRIMER/
FINISH B66W192.5 (4 MILS DRY / COAT)
ii. 2 COATS S-W DTM ACRYLIC SEMI-GLOSS PRIMER/
FINISH B66W12.5 (4 MILS DRY / COAT)
g. FERROUS METAL (PRIMER, SPRAYED) ALL EXPOSED
STRUCTURAL STEEL AND EXPOSED MECHANICAL /
ELECTRICAL ITEMS: ACRYLIC
i. 1 COAT S-W DTM ACRYLIC PRIMER/ FINISH
B66W12.5 (4 MILS DRY / COAT)
ii. 1-2 COATS S-W SUPER SAVE-LITE HI-TEC DRYFALL
B48 SERIES (6 MILS WET, 3 MILS DRY)
REMOVE AND PROTECT ALL HARDWARE, HARDWARE
ACCESSORIES, MACHINED SURFACES, PLATES, LIGHTING
FIXTURES, SPRINKLER HEADS AND SIMILAR ITEMS THAT ARE NOT
TO BE PAINTED BUT REQUIRE PROTECTION FROM THE PAINTING
PROCESS. RE-INSTALL SAME AFTER COMPLETION OF PAINTING.
MASK OFF ALL NAMEPLATES, EQUIPMENT IDENTIFICATION AND
SIMILAR ITEMS. REMOVAL AND REINSTALLATION OF ITEMS IS TO BE
DONE BY CONTRACTOR SKILLED IN SUCH WORK.
SEAL TOPS, BOTTOMS AND CUTOUTS OF UNPRIMED DOORS WITH A
HEAVY COAT OF SEALER IMMEDIATELY UPON DELIVERY TO THE
PROJECT SITE.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER
PREPARATION OF ALL SURFACES PRIOR TO THE PAINTING
INSTALLATION.
THE FINISHED PROJECT SHALL HAVE A CONSISTENT, SMOOTH
APPEARANCE OF THE SPECIFIED LUSTER.
APPLY PAINT AND STAIN PER MANUFACTURER'S TEMPRATURE AND
HUMIDITY REQUIREMENTS.
COMPLETED WORK SHALL BE FREE FROM DEFECTS AND FLAWS.
ALL PAINT COLORS AND PAINT SHEENS ARE TO BE SELECTED BY
OWNER'S REPRESENTATIVE.
SIGNAGE:
1.
2.
3.
4.
5.
6.
7.
ALL SIGNAGE SHALL MEET THE REQUIREMENTS OF THE ADA AND
ANSI.
FURNISH AND INSTALL SIGNAGE PER LOCAL, STATE AND FEDERAL
CODES.
WHERE PERMANENT IDENTIFICATION IS PROVIDED FOR ROOMS
AND SPACES, SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT
TO THE LATCH SIDE OF THE DOOR. WHERE THERE IS NO WALL
SPACE ON THE LATCH SIDE OF THE DOOR, SIGNS SHALL BE
PLACED ON THE NEAREST ADJACENT WALL.
RAISED CHARACTERS SHALL BE 48" MINIMUM ABOVE THE FLOOR,
MEASURED TO THE BASELINE OF THE LOWEST RAISED
CHARACTER, AND 60" MAXIMUM ABOVE THE FLOOR MEASURED TO
THE BASELINE OF THE HIGHEST RAISED CHARACTER.
WHERE A SIGN CONTAINING RAISED CHARACTERS AND BRAILLE IS
PROVIDED AT A DOOR, THE SIGN SHALL BE ALONGSIDE THE DOOR
AT THE LATCH SIDE. WHERE A SIGN CONTAINING RAISED
CHARACTERS AND BRAILLE IS PROVIDED AT DOUBLE DOORS WITH
ONE ACTIVE LEAF, THE SIGN SHALL BE LOCATED ON THE INACTIVE
LEAF. WHERE A SIGN CONTAINING RAISED CHARACTERS AND
BRAILLE IS PROVIDED AT DOUBLE DOORS WITH TWO ACTIVE
LEAVES, THE SIGN SHALL BE TO THE RIGHT OF THE RIGHT-HAND
DOOR. WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE OF
A SINGLE DOOR, OR TO THE RIGHT SIDE OF DOUBLE DOORS, SIGNS
SHALL BE ON THE NEAREST ADJACENT WALL. SIGNS CONTAINING
RAISED CHARACTERS AND BRAILLE SHALL BE LOCATED SO THAT
THE CLEAR FLOOR AREA 18 INCHES MINIMUM BY 18 INCHES
MINIMUM CENTERED ON THE RAISED CHARACTERS IS PROVIDED
BEYOND THE ARC OF ANY DOOR SWING BETWEEN THE CLOSED
POSITION AND 45 DEGREE OPEN POSITION.
BRAILLE SHALL LBE 48 INCHES MINIMUM AND 48 INCHES MAXIMUM
ABOVE THE FLOOR MEASURED TO THE BASELINE OF THE BRAILLE
CELLS.
COORDINATE SIGNAGE TO BE INSTALLED WITH OWNER'S
REPRESENTATIVE.
STANDING SEAM METAL ROOF PANELS:
1.
2.
3.
4.
5.
6.
7.
PROVIDE METAL ROOF PANELS AND RELATED ROOFING MATERIALS
DESIGNED TO MEET ALL APPLICABLE BUILDING CODES WIND LOAD
REQUIREMENTS FOR THE SPECIFIC PROJECT LOCATION. ROOF
SYSTEM SHALL BE DESIGNED TO MEET UL CLASS 90 WIND UPLIFT
IN ACCORDANCE WITH UL STANDARD 580 AND PANEL SYSTEM
SHALL BE ASTM 1592 TESTED AND APPROVED. THE ROOF SYSTEM
SHALL BE SUPPORTED BY ASCE 7 "STAMPED/SEALED" BY A SOUTH
CAROLINA REGISTERED ENGINEER AND PROVIDE INDEPENDENT
ENGINEERING CALCULATIONS FROM THE ROOFING SYSTEM
MANUFACTURER TO SUPPORT THE APPLICABLE ZONE 1, ZONE 2
AND ZONE 3 LOADS FOR THIS PARTICULAR PROJECT LOCATION.
EXTRAPOLATIONS WILL NOT BE ALLOWED IN THESE
CALCULATIONS, ONLY INTERPOLATIONS BY THE ENGINEER TO
ILLUSTRATE THE CLIP LAYOUT FOR EACH ZONE LISTED ABOVE.
WARRANTY: THE MANUFACTURER SHALL WARRANT FOR TWENTY
(20) YEARS FROM THE DATE OF SUBSTANTIAL COMPLETION OF THE
WORK RELATED TO THIS SECTION, THAT THE WORK IS NOT
DEFECTIVE IN WORKMANSHIP OR MATERIAL, AND THAT THE ROOF
PANELS WILL BE ADEQUATE TO PREVENT LEAKS.
a. PROVIDE MANUFACTURER'S WARRANTY FOR
WEATHERTIGHTNESS OF ROOFING SYSTEMS, INCLUDING
AGREEMENT TO REPAIR OR REPLACE ROOFING THAT FAILS
TO KEEP OUT WATER WITHIN THE SPECIFIED WARRANTY
PERIOD AS NOTED FROM DATE OF SUBSTANTIAL
COMPLETION.
b. WRITTEN TWENTY (20) YEAR FINISH WARRANTY
(COASTAL PROJECT SITE APPLICATION).
BASIS-OF-DESIGN: ROOF PANELS: SPAN-CLAD PANEL SYSTEM,
MANUFACTURED BY PETERSEN ALUMINUM CORPORATION,
WWW.PAC-CLAD.COM.
a. PANEL DESIGN: ROOF PANELS SHALL BE STANDING
SEAM IN 12" WIDTHS WITH +/-2" HIGH SEAM
b. PANEL COLOR: ZINC
c. PANEL GAGE: MINIMUM 0.032" ALUMINUM GAGE
THICKNESS.
d. TEXTURE: SMOOTH
e. LENGTH: FULL LENGTH OF ROOF SLOPE, WITHOUT
LAPPED HORIZONTAL JOINTS.
f. WIDTH: MAXIMUM PANEL COVERAGE OF 12 INCHES.
g. FINISH: KYNAR 500 OR HYLAR 5000 FLUROCARBON
COATING WITH A TOP SIDE FILM THICKNESS OF 0.70 TO 0.90
MIL OVER 0.25 TO 0.31 MIL PRIME COAT TO PROVIDE A
TOTAL DRY FILM THICKNESS OF 0.95 TO 1.25 MIL. BOTTOM
SIDE SHALL BE COATED WITH A PRIMER WITH A DRY FILM
THICKNESS OF 0.25 MIL.
OTHER ACCEPTABLE MANUFACTURERS EQUAL TO BASIS-OF-
DESIGN:
a. ATAS INTERNATIONAL, INC
b. BERRIDGE MANUFACTURING COMPANY
c. METAL-SPAN, A DIVISION OF NCI GROUP, INC.
DECK BOARD: AS RECOMMENDED BY METAL ROOFING
MANUFACTURER - SEE ALSO STRUCTURAL SPECIFICATIONS.
ROOFING UNDERLAYMENT: AS RECOMMENDED BY METAL ROOFING
MANUFACTURER.
ACCESSORIES:
a. MISCELLANEOUS SHEET METAL ITEMS: PROVIDE
FLASHINGS, GUTTERS, DOWNSPOUTS, TRIM, MOLDINGS,
CLOSURE STRIPS, PREFORMED CRICKETS, CAPS, AND
EQUIPMENT CURBS OF THE SAME MATERIAL, THICKNESS
AND FINISH AS USED FOR THE ROOFING PANELS. ITEMS
COMPLETELY CONCEALED AFTER INSTALLATION MAY
OPTIONALLY BE MADE OF STAINLESS STEEL.
i. DOWNSPOUTS: OPEN FACE, RECTANGULAR
PROFILE
b. RIB AND RIDGE CLOSURES: PROVIDE PREFABRICATED, CLOSE-FITTING COMPONENTS OF STEEL WITH
CORROSION RESISTANT FINISH OR CLOSED-CELL
SYNTHETIC RUBBER, NEOPRENE, OR PVC.
c. SEALANTS:
i. EXPOSED SEALANT: ELASTOMERIC, SILICONE, POLYURETHANE, OR SILYL-TERMINATED
POLYETHER/POLYURETHANE
ii. CONCEALED SEALANT: NON-CURING BUTLY
SEALANT OR TAPE SEALANT
iii. SEAM SEALANT: FACTORY-APPLIED, NON-
SKINNING, NON-DRYING TYPE
GUTTERS AND DOWNSPOUTS:
1.
2.
3.
4.
5.
6.
7.
GUTTERS: SMACNA (ASMM), ALUMINUM, RECTANGULAR PROFILE.
DOWNSPOUTS: ALUMINUM, RECTANGULAR PROFILE.
GUTTERS AND DOWNSPOUTS: SIZE FOR RAINFALL INTENSITY
DETERMINED BY A STORM OCCURENCE OF 1 IN 10 YEARS IN
ACCORDANCE WITH SMACNA (ASMM).
ACCESSORIES: PROFILED TO SUIT GUTTERS AND DOWNSPOUTS.
a. ANCHORAGE DEVICES: IN ACCORDANCE WITH SMACNA
(ASMM) REQUIREMENTS.
b. GUTTER SUPPORTS: BRACKETS.
c. DOWNSPOUT SUPPORTS: BRACKETS.
COLOR: TO BE SELECTED BY OWNER FROM MANUFACTURER'S
FULL RANGE.
SPLASH PADS: PRECAST CONCRETE TYPE, OF SIZE AND PROFILES
INDICATED; MINIMUM 3000 PSI AT (28) DAYS WITH MINIMUM (5)
PERCENT AIR ENTRAINMENT.
SEAL METAL JOINTS.
1.
2.
3.
4.
5.
6.
7.
8.
APPLICATION: CEILING SHEATHING, UNLESS OTHERWISE
INDICATED.
MOLD RESISTANCE: SCORE OF 10, WHEN TESTED IN
ACCORDANCE WITH ASTM D3273.
GLASS MAT FACED SHEATHING: GLASS MAT FACED GYPSUM
SUBSTRATE AS DEFINED IN ASTM C1177/C1177M.
CORE TYPE: REGULAR.
REGULAR BOARD THICKNESS: 1/2 INCH
EDGES: SQUARE.
GLASS MAT FACED PRODUCTS - USE ONE OF THE FOLLOWING:
a. AMERICAN GYPSUM COMPANY: M-GLASS EXTERIOR
SHEATHING
b. CERTAINTEED CORPORATION: GLASROC 1/2"
EXTERIOR SHEATHING
c GEORGIA-PACIFIC GYPSUM: DENSGLASS SHEATHING
FINISH EXTERIOR SHEATHING BY EMBEDDING 2" WIDE
FIBERGLASS MESH TAPE IN 90 MINUTE GYPSUM SETTING TYPE
JOINT COMPOUND OVER ALL JOINTS. UPON SETTING, APPLY A
SKIM COAT OF SETTING COMPOUND OVER THE PANELS TO
ACHIEVE A UNIFORM, SMOOTH FINISH OVER THE ENTIRE AREA.
PRIME WITH EXTERIOR GRADE PRIMER AND FINISH WITH TWO
COATS OF EXTERIOR GRADE PAINT.
FIBER CEMENT SIDING:
1.
2.
3.
4.
LAP SIDING: INDIVIDUAL HORIZONTAL BOARDS MADE OF CEMENT
AND CELLULOSE FIBER FORMED UNDER HIGH PRESSURE WITH
INTEGRAL SURFACE TEXTURE, CONFORMING TO ASTM C1186, TYPE
A, GRADE II; WITH MACHINED EDGES FOR NAIL ATTACHMENT.
BASIS-OF-DESIGN: JAMES HARDIE BUILDING PRODUCTS, INC.;
HARDIEPLANK LAP SIDING, SELECT CEDARMILL
a. STYLE: STANDARD LAP STYLE
b. LENGTH: 12 FEET NOMINAL
c. WIDTH (HEIGHT): 7-1/4 INCHES (6 INCH EXPOSURE)
d. THICKNESS: 5/16 INCH, NOMINAL
e. FINISH: FACTORY APPLIED FINISH
f. WARRANTY: 30 YEAR LIMITED
OTHER ACCEPTABLE MANUFACTURERS EQUAL TO HARDIPLANK
LAP SIDING, CEDARMILL:
a. ALLURA, A DIVISION OF PLYCEM USA, INC.
b. NICHIHA USA, INC.
ACCESSORIES:
a. FURRING STRIPS: GALVANIZED METAL MEMBERS
b. STARTER STRIPS: PROVIDE STARTER STRIPS AND
OTHER ITEMS AS RECOMMENDED BY MANUFACTURER FOR
BUILDING CONFIGURATION AND TYPE OF SIDING.
c. TRIM: SAME MATERIAL AS SIDING WITH SMOOTH FINISH
d. FASTENERS: GALVANIZED FOR COASTAL ZONE
APPLICATION AND AS RECOMMENDED BY SIDING
MANUFACTURER.
i. SCREWS FOR ACCESSORIES: STAINLESS STEEL
e. SEALANT: ELASTOMERIC, POLYURETHANE OR SILYL-
TERMINATED POLYETHER/POLYURETHANE, AND CAPABLE
OF BEING PAINTED.
f. FINISH PAINT: PAINT ACCEPTABLE TO SIDING
MANUFACTURER; PRIMER RECOMMENDED BY PAINT
MANUFACTURER FOR TOUCH-UP TO PRE-PRIMED
MATERIAL.
PORTLAND CEMENT PLASTER:
1.
2.
3.
4.
PRODUCTS:
a. PORTLAND CEMENT, AGGREGATES, AND OTHER
MATERIALS: IN ACCORDANCE WITH ASTM C926
b. PREMIXED BASE COAT: BASIS OF DESIGN - FLORIDA
STUCCO CORPORATION OR APPROVED EQUAL
c. PREMIXED FINISH COAT: BASIS OF DESIGN - FLORIDA
STUCCO CORPORATION OR APPROVED EQUAL
i. COLOR TO MATCH OWNER'S SAMPLE
ii. TABBY APPLICATION WITH 50 PERCENT #1
OYSTER SHELL AND 50 PERCENT #2 OYSTER SHELL
d. AGGREGATE: NATURAL SAND AS NEEDED FOR
APPLICATION
e. WATER: CLEAN, FRESH, POTABLE AND FREE OF
MINERAL OR ORGANIC MATTER THAT COULD ADVERSELY
AFFECT PLASTER.
METAL LATH:
a. BEADS, SCREEDS, AND JOINT ACCESSORIES AS
RECOMMENDED BY PORTLAND CEMENT PLASTER
MANUFACTURER
b. INSTALL METAL LATH OVER WATERPROOF MEMBRANE
AS RQUIRED BY WATERPROOF MEMBRANE
MANUFACTURER.
PLASTER MIXES:
a. OVER SOLID BASES: TWO COAT APPLICATION, MIXED
AND PROPORTIONED IN ACCORDANCE WITH
MANUFACTURER'S INSTRUCTIONS.
b. PREMIXED PLASTER MATERIALS: MIX IN ACCORDANCE
WITH MANUFACTURER'S INSTRUCTIONS.
c. MIX ONLY AS MUCH PLASTER AS CAN BE USED PRIOR TO
INITIAL SET.
d. MIX MATERIALS DRY, TO UNIFORM COLOR AND
CONSISTENCY, BEFORE ADDING WATER.
e. PROTECT MIXTURES FROM FREEZING, FROST, CONTAMINATION, AND EXCESSIVE EVAPORATION.
f. DO NOT RETEMPER MIXES AFTER INITIAL SET HAS
OCCURED.
PLASTERING:
a. INSTALL STUCCO LATCH OVER WATERPROOF
MEMBRANE AS REQUIRED BY WATERPROOF MEMBRANE
MANUFACTUER. PROVIDE PROTECTIVE BOARD IF
REQUIRED BY WATERPROOF MEMBRANE MANUFACTURER.
b. APPLY PREMIXED PLASTER IN ACCORDANCE WITH
MANUFACTURER'S INSTRUCTIONS.
c. APPLY PLASTER IN ACCORDANCE WITH ASTM C926
d. TWO COAT APPLICATION:
1. APPLY FIRST COAT TO NOMINAL THICKNESS OF
3/8 INCH
2. APPLY FINISH COAT TO NOMINAL THICKNESS OF
1/8 INCH.
e. MOIST CURE BASE COATS.
f. AFTER CURING, DAMPEN PREVIOUS COAT PRIOR TO
APPLYING FINISH COAT.
g. AVOID EXCESSIVE WORKING OF SURFACE. DELAY
TROWELING AS LONG AS POSSIBLE TO AVOID DRAWING
EXCESS FINES TO SURFACE.
h. AGGREGATE / OYSTER SHELL SURFACE: HAND APPLY
TO FULL SURFACE COVERAGE.
i. MOIST CURE FINISH COAT FOR MINIMUM PERIOD OF 48
HOURS.
T H
E L
IN
E
S H
O W
N A
B O
V
A C
T
LY
O N
E
IN
C H
L O
N G
A T
T
E E
T S
O R
IG
IN
A L
P A
G E
S
IZ
E
Drawing
DATE DESCRIPTION∆
T H
E S
Q U
A R
E S
A B
O V
E A
R E
C O
LO
R
, W
IT
H B
LA
D W
H
IT
E L
E T
T E
R S
, I F
P R
IN
T
E D
C O
R R
E C
T
LY
M C
Y K
ARCHITECT
Project Number:
Drawn By:
Checked By:
© Hord Coplan Macht, Inc.
A
B
C
D
1 2 3 4 5
8/
/2
3:
:2
P
M
Barry H. Taylor, AIA
GI-110
PROJECT NOTES AND
SPECIFICATIONS
W ill ia m
H ilt on P ar kw ay
H ilt on H ea d
Is la nd , S ou th
C ar ol in a, O ld
S ch o o lh o u se
P ar k T o ile t F ac ili ty
T ow n of
H ilt on H ea d
Is la nd
CIVIL ENGINEER
1536 Fording Island Road
STRUCTURAL ENGINEER
110 Traders Cross, Second Floor
MECHANICAL AND PLUMBING ENGINEER
110 Holcomb Street
STURRE ENGINEERING
SHEARLOCK ENGINEERING
ISLANDS ENGINEERING
Hilton Head Island, SC 29926
Okatie, SC 29909
Savannah, GA 31406
843.929.9432
843.473.8767
912.356.9035
224253.00 dns bht
Issue Date
AUGUST 18, 2025
ELECTRICAL ENGINEER
P.O. Box 2869
CDDC
Bluffton, SC 29910
843.384.4731
ARCHITECTURE
LANDSCAPE ARCHITECTURE
PLANNING
INTERIOR DESIGN
10 PALMETTO BUSINESS PARK
HILTON HEAD ISLAND, SC 29928
843.785.2199
HORD COPLAN MACHT
Map data (c) OpenStreetMap contributors, Microsoft, Facebook, Google, Esri Community Maps contributors, Map layer by Esri Powered by Esri
C-1
SHEET NO.
SHEET NAME
TITLE SHEET
DATE 07/16/2025
TO
HH
D
PR
P
RO
JE
CT
N U
M
BE
R:
D
PR
-0
0-
Sheet List Table Sheet No. Sheet Title
C-1 TITLE SHEET
C-4 DEMOLITION & SWPP PLAN
C-3 EXISTING CONDITIONS
VICINITY MAP
SITE
C-2 GENERAL NOTES & LEGEND
PROJECT:
OLD SCHOOLHOUSE PARK
TOILET FACILITY
PREPARED FOR:
TOWN OF HILTON HEAD
ENGINEER OF RECORD
NATHAN STURRE, P.E.
SC PE# 40266
PO Box 2227
Bluffton, SC 29910 843.929.9432
HORIZ. DATUM:
STATE PLANE, NAD83
VERT. DATUM: NAVD88
SURVEYOR
JEREMY REEDER
ATLAS SURVEYING, INC.
SC PLS#28139
168 BOARDWALK DRIVE, STE A
RIDGELAND, SC 29936
843.645.9277
C-5 SWPPP DETAILS
C-6 SWPPP DETAILS
C-7 SITE IMPROVEMENTS PLAN
C-8 GRADING & DRAINAGE PLAN
C-9 UTILITY PLAN
C-10
C-11 UTILITY DETAILS
C-12 UTILITY DETAILS
PERMIT PLANS FOR
OLD SCHOOLHOUSE PARK
TOILET FACILITY
HILTON HEAD ISLAND, SC
PARCEL R511 007 000 0070 0000
EXISTING LAND USE: MUNICIPAL
FUTURE LAND USE: MUNICIPAL
152 WILLIAM HILTON PARKWAY
HILTON HEAD ISLAND, SOUTH CAROLINA 29926
HORIZONTAL DATUM IS BASED OFF
STATE PLANE COORDINATES NAD83.
VERTICAL DATUM IS NAVD88.
LATITUDE: 32°21'55.26"N
LONGITUDE: 80°75'07.28"W
TOWN OF HILTON HEAD ISLAND
PHONE: (843) 341-4600
1 TOWN CENTER COURT
HILTON HEAD ISLAND, SC 29928
PROPERTY OWNER / DEVELOPER
CIVIL DETAILS
7/16/2025
C-2
SHEET NO.
SHEET NAME
GENERAL NOTES & LEGEND
DATE
ENGINEER OF RECORD
NATHAN STURRE, P.E.
SC PE# 40266
PO Box 2227
Bluffton, SC 29910 843.929.9432
HORIZ. DATUM:
STATE PLANE, NAD83
VERT. DATUM: NAVD88
K
L
M
N
O
P
R
S
T
U
V
W
07/16/2025
PROJECT DATA:
UTILITIES:
PROJECT:
OLD SCHOOLHOUSE PARK
TOILET FACILITY
PREPARED FOR:
TOWN OF HILTON HEAD
SURVEYOR
JEREMY REEDER
ATLAS SURVEYING, INC.
SC PLS#28139
168 BOARDWALK DRIVE, STE A
RIDGELAND, SC 29936
843.645.9277
WILLIAM HILTON PARKWAY
U.S. HIGHWAY 278 R/W VARIES
N/F
KENNETH & MARGARETE JAMES
N/F
TUAN Q. NGUYEN
N/F
TOWN OF HILTON HEAD ISLAND
N/F
HEIRS OF HENRY SIMMONS
N/F
THE TOWN OF
HILTON HEAD ISLAND
N/F
DANIEL FRAZIER IV
N/F
HILTON HEAD CO INC.
PICKLEBALL
COURT
BASKETBALL
COURT
WILLIAM HILTON PARKWAY
U.S. HIGHWAY 278 R/W VARIES
N/F
TOWN OF HILTON HEAD ISLAND
N/F
BEAUFORT COUNTY
PICKLEBALL
COURT
EXISTING 1" WATER
HOSE BIBB
APPROXIMATE LINE OF
EXISTING TREE LINE
EXISTING
PARKING LOT
PROPERTY LINE
PROPERTY LINE
EXISTING CONCRETE SIDEWALK
C-3
EXISTING CONDITIONS
HORIZONTAL SCALE 1" = 40'
PLAN
SHEET NO.
SHEET NAME
DATE
ENGINEER OF RECORD
NATHAN STURRE, P.E.
SC PE# 40266
PO Box 2227
Bluffton, SC 29910 843.929.9432
HORIZ. DATUM:
STATE PLANE, NAD83
VERT. DATUM: NAVD88
07/16/2025
PROJECT:
OLD SCHOOLHOUSE PARK
TOILET FACILITY
PREPARED FOR:
TOWN OF HILTON HEAD
SURVEYOR
JEREMY REEDER
ATLAS SURVEYING, INC.
SC PLS#28139
168 BOARDWALK DRIVE, STE A
RIDGELAND, SC 29936
N/F
TOWN OF HILTON HEAD ISLAND
N/F
DANIEL FRAZIER IV
PICKLEBALL
COURT
N/F
TOWN OF HILTON HEAD ISLAND
PICKLEBALL
COURT
EXISTING 1" WATER
HOSE BIBB
APPROXIMATE LINE OF
EXISTING TREE LINE
EXISTING
PARKING LOT
PERTY LINE
EXISTING CONCRETE SIDEWALK
C-4
DEMOLITION &
SWPP PLAN
HORIZONTAL SCALE 1" = 20'
PLAN
SHEET NO.
SHEET NAME
DATE
ENGINEER OF RECORD
NATHAN STURRE, P.E.
SC PE# 40266
PO Box 2227
Bluffton, SC 29910 843.929.9432
HORIZ. DATUM:
STATE PLANE, NAD83
VERT. DATUM: NAVD88
07/16/2025
PROJECT:
OLD SCHOOLHOUSE PARK
TOILET FACILITY
PREPARED FOR:
TOWN OF HILTON HEAD
SURVEYOR
JEREMY REEDER
ATLAS SURVEYING, INC.
SC PLS#28139
168 BOARDWALK DRIVE, STE A
RIDGELAND, SC 29936
C-5
SWPPP DETAILS
SHEET NO.
SHEET NAME
DATE
ENGINEER OF RECORD
NATHAN STURRE, P.E.
SC PE# 40266
PO Box 2227
Bluffton, SC 29910 843.929.9432
HORIZ. DATUM:
STATE PLANE, NAD83
VERT. DATUM: NAVD88
07/16/2025
PROJECT:
OLD SCHOOLHOUSE PARK
TOILET FACILITY
PREPARED FOR:
TOWN OF HILTON HEAD
SURVEYOR
JEREMY REEDER
ATLAS SURVEYING, INC.
SC PLS#28139
168 BOARDWALK DRIVE, STE A
RIDGELAND, SC 29936
843.645.9277
FLAT-BOTTOM TRENCH DETAIL
V-SHAPED TRENCH DETAIL
SILT FENCE INSTALLATION
STANDARD DRAWING NO.
South Carolina Department of Health and Environmental Control
PLAN SYMBOL
DATE
South Carolina Department of Health and Environmental Control
DATE
STRAW BALES OR ABOVE GROUND
CONCRETE WASHOUT
SOUTH CAROLINA DEPARTMENT OF PUBLIC HEALTH
STANDARD DRAWING NO. RC-07 [PAGE 1]
SECTION B-B
PLAN
B B
STRAW BALE BARRIER CONCRETE WASHOUT
NOTES
CONCRETE WASHOUT SIGN DETAIL
CONCRETE
WASHOUT
TEMPORARY STOCKPILE
South Carolina Department of Health and Environmental Control
DATE
TEMPORARY STOCKPILE AREA
TREE PROTECTION FENCE DETAIL
N.T.S.
SPECIMEN TREE PROTECTION FENCE DETAIL
N.T.S.
South Carolina Department of Health and Environmental Control
PLAN SYMBOL
DATE
South Carolina Department of Health and Environmental Control
CONSTRUCTION ENTRANCE
DATE
C-6
SWPPP DETAILS
SHEET NO.
SHEET NAME
DATE
ENGINEER OF RECORD
NATHAN STURRE, P.E.
SC PE# 40266
PO Box 2227
Bluffton, SC 29910 843.929.9432
HORIZ. DATUM:
STATE PLANE, NAD83
VERT. DATUM: NAVD88
07/16/2025
PROJECT:
OLD SCHOOLHOUSE PARK
TOILET FACILITY
PREPARED FOR:
TOWN OF HILTON HEAD
SURVEYOR
JEREMY REEDER
ATLAS SURVEYING, INC.
SC PLS#28139
168 BOARDWALK DRIVE, STE A
RIDGELAND, SC 29936
N/F
TOWN OF HILTON HEAD ISLAND
N/F
DANIEL FRAZIER IV
PICKLEBALL
COURT
N/F
TOWN OF HILTON HEAD ISLAND
PICKLEBALL
COURT
FD
EXISTING 1" WATER
HOSE BIBB
APPROXIMATE LINE OF
EXISTING TREE LINE
EXISTING
PARKING LOT
PERTY LINE
EXISTING CONCRETE SIDEWALK
C-7
SITE IMPROVEMENTS PLAN
HORIZONTAL SCALE 1" = 20'
PLAN
SHEET NO.
SHEET NAME
DATE
ENGINEER OF RECORD
NATHAN STURRE, P.E.
SC PE# 40266
PO Box 2227
Bluffton, SC 29910 843.929.9432
HORIZ. DATUM:
STATE PLANE, NAD83
VERT. DATUM: NAVD88
07/16/2025
PROJECT:
OLD SCHOOLHOUSE PARK
TOILET FACILITY
PREPARED FOR:
TOWN OF HILTON HEAD
SURVEYOR
JEREMY REEDER
ATLAS SURVEYING, INC.
SC PLS#28139
168 BOARDWALK DRIVE, STE A
RIDGELAND, SC 29936
N/F
TOWN OF HILTON HEAD ISLAND
N/F
DANIEL FRAZIER IV
PICKLEBALL
COURT
N/F
TOWN OF HILTON HEAD ISLAND
PICKLEBALL
COURT
FD
EXISTING 1" WATER
HOSE BIBB
APPROXIMATE LINE OF
EXISTING TREE LINE
EXISTING
PARKING LOT
PERTY LINE
EXISTING CONCRETE SIDEWALK
C-8
GRADING & DRAINAGE PLAN
HORIZONTAL SCALE 1" = 20'
PLAN
SHEET NO.
SHEET NAME
DATE
ENGINEER OF RECORD
NATHAN STURRE, P.E.
SC PE# 40266
PO Box 2227
Bluffton, SC 29910 843.929.9432
HORIZ. DATUM:
STATE PLANE, NAD83
VERT. DATUM: NAVD88
07/16/2025
PROJECT:
OLD SCHOOLHOUSE PARK
TOILET FACILITY
PREPARED FOR:
TOWN OF HILTON HEAD
SURVEYOR
JEREMY REEDER
ATLAS SURVEYING, INC.
SC PLS#28139
168 BOARDWALK DRIVE, STE A
RIDGELAND, SC 29936
N/F
TOWN OF HILTON HEAD ISLAND
N/F
DANIEL FRAZIER IV
PICKLEBALL
COURT
N/F
TOWN OF HILTON HEAD ISLAND
PICKLEBALL
COURT
FD
EXISTING 1" WATER
HOSE BIBB
APPROXIMATE LINE OF
EXISTING TREE LINE
EXISTING
PARKING LOT
PERTY LINE
EXISTING CONCRETE SIDEWALK
C-9
UTILITY PLAN
HORIZONTAL SCALE 1" = 20'
PLAN
SHEET NO.
SHEET NAME
DATE
ENGINEER OF RECORD
NATHAN STURRE, P.E.
SC PE# 40266
PO Box 2227
Bluffton, SC 29910 843.929.9432
HORIZ. DATUM:
STATE PLANE, NAD83
VERT. DATUM: NAVD88
07/16/2025
PROJECT:
OLD SCHOOLHOUSE PARK
TOILET FACILITY
PREPARED FOR:
TOWN OF HILTON HEAD
SURVEYOR
JEREMY REEDER
ATLAS SURVEYING, INC.
SC PLS#28139
168 BOARDWALK DRIVE, STE A
RIDGELAND, SC 29936
C-10
CIVIL DETAILS
SHEET NO.
SHEET NAME
DATE
ENGINEER OF RECORD
NATHAN STURRE, P.E.
SC PE# 40266
PO Box 2227
Bluffton, SC 29910 843.929.9432
HORIZ. DATUM:
STATE PLANE, NAD83
VERT. DATUM: NAVD88
07/16/2025
PROJECT:
OLD SCHOOLHOUSE PARK
TOILET FACILITY
PREPARED FOR:
TOWN OF HILTON HEAD
SURVEYOR
JEREMY REEDER
ATLAS SURVEYING, INC.
SC PLS#28139
168 BOARDWALK DRIVE, STE A
RIDGELAND, SC 29936
843.645.9277
A
A
WHEEL STOP
N.T.S.
ISOMETRIC PLAN VIEW SECTION A-A
CONCRETE SIDEWALK DETAIL
N.T.S.
CONCRETE ADA PAD DETAIL
N.T.S.
N.T.S.
INFILTRATION BASIN
C-11
UTILITY DETAILS
SHEET NO.
SHEET NAME
DATE
ENGINEER OF RECORD
NATHAN STURRE, P.E.
SC PE# 40266
PO Box 2227
Bluffton, SC 29910 843.929.9432
HORIZ. DATUM:
STATE PLANE, NAD83
VERT. DATUM: NAVD88
07/16/2025
PROJECT:
OLD SCHOOLHOUSE PARK
TOILET FACILITY
PREPARED FOR:
TOWN OF HILTON HEAD
SURVEYOR
JEREMY REEDER
ATLAS SURVEYING, INC.
SC PLS#28139
168 BOARDWALK DRIVE, STE A
RIDGELAND, SC 29936
C-12
UTILITY DETAILS
SHEET NO.
SHEET NAME
DATE
ENGINEER OF RECORD
NATHAN STURRE, P.E.
SC PE# 40266
PO Box 2227
Bluffton, SC 29910 843.929.9432
HORIZ. DATUM:
STATE PLANE, NAD83
VERT. DATUM: NAVD88
07/16/2025
PROJECT:
OLD SCHOOLHOUSE PARK
TOILET FACILITY
PREPARED FOR:
TOWN OF HILTON HEAD
SURVEYOR
JEREMY REEDER
ATLAS SURVEYING, INC.
SC PLS#28139
168 BOARDWALK DRIVE, STE A
RIDGELAND, SC 29936
STRUCTURAL
NOTES
RO
OF
: 7 T
O
DE
GR
EE
S a a
GABLE ROOF a = 3.0 FT
COMPONENTS & CLADDING
W
AL
LS
2r
2e
3r
3e
2n a a
3r
3e
2n
ZONE AREA(SF) +P -P ASD
+P ASD -P
1 10 4.6 84.5 28.0 51.2
1 20 41.4 72.4 24.8 43.4
1 50 34.5 55.3 20.7 33.2
1 100 29.3 42.3 17.6 25.4
2e 10 46.6 85.4 28.0 51.2
2e 20 41.4 72.4 24.8 43.4
2e 50 34.5 55.3 20.7 33.2
2e 100 29.3 42.3 17.6 25.4
2n 10 46.6 94.0 28.0 56.4
2n 20 41.4 84.1 24.8 50.5
2n 50 34.5 70.9 10.7 42.5
2n 100 29.3 60.9 17.6 36.5
2r 10 46.6 85.4 28.0 51.2
2r 20 41.4 72.4 24.8 43.4
2r 50 34.5 55.3 20.7 33.2
2r 100 29.3 42.3 17.6 25.4
3e 10 46.6 115.3 28.0 69.2
3e 20 41.4 102.2 24.8 61.3
3e 50 34.5 84.8 20.7 50.9
3e 100 29.3 71.7 17.6 43.0
3r 10 46.6 94.0 28.0 56.4
3r 20 41.4 84.1 24.8 50.5
3r 50 34.5 70.9 20.7 42.5
3r 100 29.3 60.9 17.6 36.5
4 10 60.5 65.6 36.3 39.4
4 20 57.7 62.9 34.6 37.7
4 50 54.1 59.3 32.5 35.6
4 100 51.4 56.5 30.8 33.9
5 10 60.5 80.9 36.3 48.5
5 20 57.7 75.5 34.6 45.3
5 50 54.1 68.3 32.5 41.0
5 100 51.4 62.9 30.8 37.7
WIND PRESSURES (PSF)
1. BUILDING CODE:
2021 SOUTH CAROLINA BUILDING CODE (SCBC):
2. GRAVITY LOADS (ASCE 7-16):
DISTRIBUTED
ROOF LL = 20 PSF
DL = 15 PSF
ELEVATED FLOOR LL = 100 PSF
DL = 20 PSF
1ST FLOOR LL = SEE CHART
DL = 50 PSF
COLLATERAL LOAD CL = 5 PSF
3. WIND LOADS (ASCE 7-16/ 2021 SCBC):
BASIC DESIGN WIND SPEED, V = 145mph ALLOWABLE STRESS DESIGN WIND SPEED, VASD = 112.3mph
RISK CATEGORY II
WIND EXPOSURE C
INTERNAL PRESSURE COEFFICIENT, GC^pi = ±0.18
4. SEISMIC LOADS (ASCE 7-16/ 2021 SCBC):
RISK CATEGORY II
SEISMIC IMPORTANCE FACTOR, IE = 1.00
MAPPED SPECTRAL RESPONSE ACCELERATION PARAMETERS:
SS = 0.447g; S1 = 0.149g
SITE CLASS D
DESIGN SPECTRAL RESPONSE ACCELERATION PARAMETERS:
SDS = 0.430g; SD1 = 0.229g
SEISMIC DESIGN CATEGORY D
BASIC SEISMIC FORCE-RESISTING SYSTEM:
ORDINARY REIFNORCED MASONRY SHEAR WALLS
DESIGN BASE SHEAR:
V = CsW
W = EFFECTIVE SEISMIC MASS
SEISMIC RESPONSE COEFFICIENT, CS = 0.205
RESPONSE MODIFICATION FACTOR, R = 2
ANALYSIS PROCEDURE:
EQUIVALENT LATERAL FORCE METHOD
5. SNOW LOAD (ASCE 7-16):
GROUND SNOW LOAD Pg = 0 PSF
6. RAIN LOAD DATA (2021 SCBC):
RAIN INTENSITY i = 4.5 in/hr
STRUCTURAL NOTES STRUCTURAL DESIGN CRITERIA
GENERAL REQUIREMENTS
1. WHERE A SECTION OR DETAIL IS SHOWN FOR ONE CONDITION, IT SHALL APPLY TO ALL SIMILAR CONDITIONS.
2. COORDINATE ALL LIMITS AND DEPTHS OF DEPRESSIONS FOR FLOOR FINISHES WITH ARCHITECTURAL
DRAWINGS AND SCHEDULES. LIMITS SHOWN ON STRUCTURAL DRAWINGS ARE SCHEMATIC.
3. THE DESIGN ADEQUACY AND SAFETY OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC. SHALL BE
THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
4. DO NOT SCALE DRAWINGS. FOLLOW DIMENSIONS SHOWN ON PLANS.
5. CONTRACTOR SHALL COORDINATE AND VERIFY ALL DIMENSIONS AND ELEVATIONS SHOWN HEREIN WITH
ARCHITECTURAL PLANS, SECTIONS, AND DETAILS PRIOR TO CONSTRUCTION OR MATERIAL PURCHASE AND SHALL NOTIFY ARCHITECT OR ENGINEER IN WRITING OF DISCREPANCIES. SEE ARCHITECTURAL DRAWINGS
FOR ALL DIMENSIONS AND ELEVATIONS NOT SHOWN HEREIN.
6. DIMENSIONS INDICATED RELATIVE TO AN EXISTING STRUCTURE ARE APPROXIMATE AND SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION OR MATERIALS PURCHASE. CONTRACTOR SHALL
NOTIFY ARCHITECT OR ENGINEER IN WRITING OF DISCREPANCIES.
7. SPECIFIED ANCHOR SYSTEMS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS. SPECIAL ATTENTION SHALL BE GIVEN TO THE DRILLING, CLEANING, AND PREPARATION OF HOLES. WHERE ADHESIVE ANCHORS ARE SHOWN, SPECIAL ATTENTION SHALL BE GIVEN TO THE REQUIRED
MIXING, APPLICATION, AND CURING TIME OF ADHESIVE TYPE SPECIFIED.
SUBGRADE PREPARATION
1. CONTRACTOR SHALL STRIP AND REMOVE ALL VEGETATION, TOPSOIL, ROOTS, AND ORGANIC SOILS FROM THE
CONSTRUCTION AREA FOR A DISTANCE OF AT LEAST 10' BEYOND THE EXTENT OF BUILDING FOUNDATION LIMITS. THE DEPTH OF STRIPPING SHALL BE THAT REQUIRED TO REMOVE SIGNIFICANT ROOT ZONES, SMALL TREE STUMPS, AND OTHER UNACCEPTABLE MATERIALS, BUT IN NO CASE SHALL IT BE LESS THAN 12".
2. AFTER TOPSOILS, ETC. HAVE BEEN REMOVED FROM THE SITE WITHIN AND TO A POINT 10' OUTSIDE THE BUILDING CONSTRUCTION AREA, THE UPPER 24" OF EXPOSED SOILS SHALL BE COMPACTED TO A MINIMUM DENSITY OF 95% MODIFIED PROCTOR MAXIMUM DRY DENSITY (ASTM D1557) BY PROOFROLLING WITH A FULLY LOADED PNEUMATIC TIRED TANDEM AXLE DUMP TRUCK CAPABLE OF TRANSFERRING A LOAD OF 10 TO 20 TONS BY OVERLAPPING PASSES. A MINIMUM OF 8 COMPLETE PASSES SHALL BE MADE WITHIN THE BUILDING AREA.
3. PROOFROLLING SHALL BE PERFORMED UNDER THE OBSERVATION OF AN APPROVED TESTING LABORATORY SUPERVISED BY A GEOTECHNICAL ENGINEER. UNDERCUT, BACKFILL, AND COMPACT AREAS WHICH PUMP, DEFLECT, OR RUT EXCESSIVELY OR WHICH DO NOT STABILIZE AFTER SUCCESSIVE PASSES OF PROOFROLLING
EQUIPMENT.
4. AFTER COMPLETION OF DENSIFICATION OF EXISTING SOILS, PLACE STRUCTURAL FILL FOR BUILDING AND PAVEMENT AREAS IN THIN (8" TO 10") LIFTS COMPACT TO A MINIMUM DENSITY OF 95% MODIFIED PROCTOR MAXIMUM DRY DENSITY (ASTM D1557). MATERIAL USED AS STRUCTURAL FILL SHALL BE NON-PLASTIC GRANULAR MATERIAL CONTAINING LESS THAN 15% FINES PASSING THROUGH THE NO. 200 SIEVE AND FREE OF
ORGANICS, BOULDERS, OR OTHER DELETERIOUS MATERIALS.
CAST-IN-PLACE REINFORCED CONCRETE
1. THE FOLLOWING ACI STANDARDS (LATEST EDITION) APPLY:
A. ACI 318 - CODE
B. ACI 315 - DETAILING
C. ACI 301 - SPECIFICATIONS
D. ACI 304 - PLACING
E. ACI 347 - FORMWORK
F. ACI 211.1 - MIX PROPORTIONING
G. ACI 305 - HOT WEATHER CONCRETING
H. ACI 306 - COLD WEATHER CONCRETING
2. ALL CONCRETE SHALL BE NORMAL WEIGHT CONCRETE (145 PCF) WITH MIXES MEETING THE FOLLOWING
CRITERIA:
STRUCTURAL ELEMENT 28 DAY COMPRESSIVE STRENGTH
FOOTINGS, GRADE BEAMS &
FOUNDATION WALLS 3,000 PSI
SLAB ON GRADE 3,000 PSI
ELEVATED SLABS & BEAMS 4,000 PSI
COLUMNS 4,000 PSI
3. SLUMP SHALL NOT EXCEED 5".
SLAB ON GRADE
1. APPLY AN APPROVED CURING COMPOUND CONFORMING TO ASTM C309 AFTER FINISHING THE SLAB.
2. ALL WELDED WIRE FABRIC SHALL BE IN ACCORDANCE WITH ASTM A185. LAP ADJOINING PIECES AT LEAST
ONE FULL MESH OR 8" MINIMUM. UNLESS OTHERWISE APPROVED, ALL WELDED WIRE FABRIC SHALL BE BLOCKED INTO POSITION INDICATED WITH PRECAST CONCRETE BLOCKS HAVING A COMPRESSIVE STRENGTH
EQUAL TO THAT OF THE SLAB.
3. THE USE OF POLYPROPYLENE FIBERS (IN LIEU OF WELDED WIRE FABRIC) IS PROHIBITED WITHOUT THE
WRITTEN AUTHORIZATION OF THE ENGINEER.
4. THE MAXIMUM SPACING OF JOINTS SHALL BE 15' OR AS SHOWN ON PLANS.
5. ALL POROUS FILL MATERIAL SHALL BE A CLEAN GRANULAR MATERIAL WITH 100% PASSING 1 12" SIEVE AND
NO MORE THAN 5% PASSING A NO. 4 SIEVE. POROUS FILL SHALL BE COMPACTED TO 95% MODIFIED
PROCTOR. DRY DENSITY PER ASTM D1557.
6. SLAB JOINTS SHALL BE FILLED WITH APPROVED MATERIAL. THIS SHOULD TAKE PLACE AS LATE AS POSSIBLE, PREFERABLY 4 TO 6 WEEKS AFTER THE SLAB HAS BEEN CAST. PRIOR TO FILLING, REMOVE ALL DEBRIS FROM THE SLAB JOINTS, THEN FILL IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS.
7. SEE THE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS OF DEPRESSED SLAB AREAS AND DRAINS. SLOPE
SLAB TO DRAINS WHERE SHOWN.
8. THE FINISH TOLERANCE OF ALL SLABS SHALL BE IN ACCORDANCE WITH ACI 301, TYPE A.
9. WALKWAYS AND OTHER EXTERIOR SLABS ARE NOT INDICATED ON THE STRUCTURAL DRAWINGS. SEE THE
SITE PLAN AND ARCHITECTURAL DRAWINGS FOR LOCATIONS, DIMENSIONS, ELEVATIONS, JOINTING DETAILS
AND FINISH DETAILS.
10. CONTROL JOINT SEALANT SHALL BE SIKADUR 51 NS/SL OR APPROVED EQUAL. EXPANSION AND ISOLATION JOINT SEALANT SHALL BE SIKAFLEX 1a OR APPROVED EQUAL.
REINFORCING STEEL
1. ALL REINFORCING STEEL SHALL BE ASTM A615, GRADE 60, UNLESS NOTED OTHERWISE.
2. ALL WELDED WIRE FABRIC SHALL BE ASTM A185, 70 KSI MINIMUM YIELD STRENGTH.
3. ADDITIONAL REINFORCING AND THAT QUANTITY OF REINFORCING OCCURRING AT OPENINGS SHALL
BE PLACED EQUALLY EACH SIDE OF OPENINGS AS DETAILED.
4. HOOKS IN REINFORCING ARE IN ADDITION TO LENGTH SHOWN.
5. REINFORCING IS TO BE SUPPORTED IN FORMS AND SPACED WITH WIRE BAR SUPPORTS ACCORDING
TO CRSI "PLACING REINFORCING BARS" UNLESS NOTED OTHERWISE.
6. MINIMUM REINFORCING STEEL CLEAR COVERS ARE AS FOLLOWS:
A. CONCRETE CAST DIRECTLY AGAINST EARTH - 3"
B. INTERIOR SLABS - 1"
C. INTERIOR BEAMS AND COLUMNS - 1 1/2"
D. EXTERIOR BEAMS AND COLUMNS - 2"
E. EXTERIOR SLABS - 1 1/2"
7. UNLESS NOTED OTHERWISE, ALL BAR REINFORCING LAP SPLICES SHALL HAVE A MINIMUM LAP LENGTH
OF 48 BAR DIAMETERS.
PLYWOOD / GYPBOARD SHEATHING
1. ALL PLYWOOD CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE AMERICAN PLYWOOD ASSOCIATION (APA)
SPECIFICATIONS.
2. ALL ROOF PANEL SHEATHING SHALL BE PER PLAN. SUITABLE EDGE SUPPORT SHALL BE PROVIDED BY THE USE OF PANEL
CLIPS OR BLOCKING BETWEEN FRAMING.
3. ALL FLOOR SHEATHING SHALL BE TONGUE &…
This is the start of the file's text. The full file is on GovTribe.