2. MINIMUM AND SPECIFIC REQUIREMENTS.pdf
PDF 149 KB Posted
- Solicitation number
- DACA175260001800
About this file
This document outlines the minimum and specific requirements for an Armed Forces Career Center lease space. The facility must contain between 1,607 and 2,115 gross square feet and must meet baseline requirements applicable to all locations, including secondary egress from individual offices, 24-hour lighted or secured parking for five government vehicles, adequate parking for service members' privately owned vehicles during working hours, 24-hour access to leased spaces, and high-speed data service connection from the street to the building demarcation point.
Service-specific requirements vary by branch. The Air Force requires an open area with two workstations, one 50 square foot testing/conference room with window or glass door for test monitoring, and one 60 square foot storage room. The Navy requires three workstations in an open area, one 50 square foot testing/conference room, and one 60 square foot storage room. The USMC requires one workstation in an open area, one 50 square foot testing/conference room, and one 60 square foot storage room. All locations must include one network/CCTV security closet of approximately 54 square feet (located in the private office for single-service stations or in the common area for multi-service stations), a minimum of one unisex 100 square foot ADA-compliant restroom (with potential for additional restrooms as specified in construction specifications), and one janitorial closet of at least 20 square feet with specific requirements detailed in construction specifications.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| b. General Clause, GSA Form 3517B.pdf | ||
| a. U.S. Government Lease for Real Property.pdf | ||
| 3. Construction and Security Specifications.pdf | ||
| 4. Janitorial Services Specification - Requirements.pdf | ||
| 3a. Construction_Specifications_Bid_Proposal_Worksheet.xlsx | XLSX spreadsheet | |
| 1. Proposal to Lease Space Worksheet.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
- 1 -
Minimum and Specific Requirements
Armed Forces Career Center
Minimum Gross Square Footage: 1,607 SF
Maximum Gross Square Footage: 2,115 SF
Minimum Requirements for All Locations:
1. Secondary egress for each individual office leading away from the main entry door or shared common corridor.
2. 24-hour lighted or secured parking within the lessor’s premises for five (5) Government vehicle.
3. Adequate parking for service member privately owned vehicles during working hours.
4. 24-hour access to the leased spaces.
5. High-speed data service connection from the street to the building demarcation point.
Air Force Specific Requirements:
1. Open Space for cubicles or workstations: Space lay out to include an open area within the suite for two (2) workstations.
2. Testing/Conference Room: One (1) testing room of 50 SF with a window or a glass door facing the open area for test monitoring.
Storage Room: One (1) storage room of 60 SF for supplies/equipment storage, preferably in the rear of the suite.
Navy Specific Requirements:
1. Open Space for cubicles or workstations: Space lay out to include an open area within the suite for three (3) workstations.
2. Testing/Conference Room: One (1) testing room of 50 SF with a window or a glass door facing the open area for test monitoring.
Minimum and Specific Requirements
- 2 -
3. Storage Room: One (1) storage room of 60 SF for supplies/equipment storage, preferably in the rear of the suite.
USMC Specific Requirements:
1. Open Space for cubicles or workstations: Space lay out to include an open area within the suite for one (1) workstation.
2. Testing/Conference Room: One (1) testing room of 50 SF with a window or a glass door facing the open area for test monitoring.
3. Storage Room: One (1) storage room of 60 SF for supplies/equipment storage, preferably in the rear of the suite.
1. Network/CCTV (Security) Closet: One (1) network equipment closet of approximately 54 SF for CCTV system and entry control system housing. This closet should be located in the private office if a single Service station or built into the common area if a multiple Service station.
2. Restrooms: A minimum of one (1) unisex 100 SF restroom meeting ADA specifications. Construction specifications will indicate if more than one restroom is required.
3. Janitorial Closet: One (1) janitorial equipment closet of a minimum of 20 SF, specific requirements detailed within the construction specifications.