2. MINIMUM AND SPECIFIC REQUIREMENTS.pdf

PDF 105 KB Posted

Attached to
Recruiting - Air Force Career Center - Stuart, FL
Solicitation number
DACA175260001700
Issued by

About this file

This document specifies the minimum and spatial requirements for a United States Air Force Career Center lease space. The facility must be between 870 and 1,145 gross square feet and include specific rooms and functional areas to support Air Force recruiting and testing operations.

The minimum requirements for all locations include secondary egress from individual offices, 24-hour lighted or secured parking for two government vehicles, adequate parking for service member privately owned vehicles during working hours, 24-hour access to the leased space, and high-speed data service connection from the street to the building demarcation point. Air Force-specific requirements mandate an open area for three workstations, one 50-square-foot testing/conference room with a window or glass door facing the open area for test monitoring, one 60-square-foot storage room for supplies and equipment (preferably in the rear), one 36-square-foot network/CCTV security closet for equipment housing, a minimum of one 100-square-foot unisex ADA-compliant restroom, and one 20-square-foot janitorial closet. The network/CCTV closet location depends on whether it is a single or multiple service station configuration.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Minimum and Specific Requirements

- 1 -

United States Air Force Career Center

Minimum Gross Square Footage: 870 SF

Maximum Gross Square Footage: 1,145 SF

Minimum Requirements for All Locations:

1. Secondary egress for each individual office leading away from the main entry door or shared common corridor.

2. 24-hour lighted or secured parking within the lessor’s premises for two (2) Government vehicles.

3. Adequate parking for service member privately owned vehicles during working hours.

4. 24-hour access to the leased spaces.

5. High-speed data service connection from the street to the building demarcation point.

Air Force Specific Requirements:

1. Open Space for cubicles or workstations: Space lay out to include an open area within the suite for three (3) workstations.

2. Testing/Conference Room: One (1) testing room of 50 SF with a window or a glass door facing the open area for test monitoring.

3. Storage Room: One (1) storage room of 60 SF for supplies/equipment storage, preferably in the rear of the suite.

4. Network/CCTV (Security) Closet: One (1) network equipment closet of approximately 36 SF for CCTV system and entry control system housing. This closet should be located in the private office if a single Service station, or built into the common area if a multiple Service station.

5. Restrooms: A minimum of one (1) unisex 100 SF restroom meeting ADA specifications. Construction specifications will indicate if more than one restroom is required.

Minimum and Specific Requirements

- 2 -

6. Janitorial Closet: One (1) janitorial equipment closet of a minimum of 20 SF, specific requirements detailed within the construction specifications.

File details come from the government source that posted it. Updated .