2. MINIMUM AND SPECIFIC REQUIREMENTS.pdf
PDF 106 KB Posted
- Solicitation number
- DACA175260001100
About this file
This document outlines the Minimum and Specific Requirements for a United States Marine Corps Career Center facility lease. The space requirements range from 1,140 to 1,215 gross square feet and include several mandatory specifications: 24-hour secured parking for three government vehicles, adequate parking for service members, 24-hour facility access, and high-speed data connectivity. Specific spatial requirements include one 125 SF private office, an open area for three workstations, an 80 SF testing/conference room, an 80 SF storage room, a 36 SF network/security closet, a 100 SF ADA-compliant unisex restroom, and a 20 SF janitorial equipment closet. Additional requirements include a secondary egress for each office and detailed construction specifications to be followed for each space component.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 3a. Construction_Specifications_Bid_Proposal_Worksheet.xlsx | XLSX spreadsheet | |
| a. U.S. Government Lease for Real Property.pdf | ||
| 1. Proposal to Lease Space Worksheet.xlsx | XLSX spreadsheet | |
| 3. Construction Specifications.pdf | ||
| b. General Clause, GSA Form 3517B.pdf | ||
| 4. Janitorial Services Specification - Requirements.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Minimum and Specific Requirements
- 1 -
United States Marine Corps Career Center
Minimum Gross Square Footage: 1,140 SF
Maximum Gross Square Footage: 1,215 SF
Minimum Requirements for All Locations:
1. Secondary egress for each individual office leading away from the main entry door or shared common corridor.
2. 24-hour lighted or secured parking within the lessor’s premises for three (3) Government vehicles.
3. Adequate parking for service member privately owned vehicles during working hours.
4. 24-hour access to the leased spaces.
5. High-speed data service connection from the street to the building demarcation point.
USMC Specific Requirements:
1. Private Offices: One (1) private office of 125 SF within each individual Armed Forces Center; see specific requirements detailed within the construction specifications.
2. Open Space for cubicles or workstations: Space lay out to include an open area within the suite for three (3) workstations.
3. Testing/Conference Room: One (1) testing room of 80 SF with a window or a glass door facing the open area for test monitoring.
4. Storage Room: One (1) storage room of 80 SF for supplies/equipment storage, preferably in the rear of the suite.
5. Network/CCTV (Security) Closet: One (1) network equipment closet of approximately 36 SF for CCTV system and entry control system housing. This closet should be located in the private office if a single Service station or built into the common area if a multiple Service station.
6. Restrooms: A minimum of one (1) unisex 100 SF restroom meeting ADA specifications. Construction specifications will indicate if more than one restroom is
Minimum and Specific Requirements
- 2 -required.
7. Janitorial Closet: One (1) janitorial equipment closet of a minimum of 20 SF, specific requirements detailed within the construction specifications.