2. MINIMUM AND SPECIFIC REQUIREMENTS.pdf
PDF 108 KB Posted
- Solicitation number
- DACA175260001500
About this file
This document is a Minimum and Specific Requirements specification for an Armed Forces Career Center lease. The requirements cover both general and service-specific (USMC and Army) space needs for a facility between 3,600-3,944 gross square feet. Minimum requirements for all locations include secondary egress for offices, 24-hour secured parking for 11 government vehicles, adequate parking for service members' personal vehicles, 24-hour facility access, and high-speed data service connection.
Service-specific requirements differ in workspace configurations: USMC needs one 125 SF private office, four workstation spaces, an 80 SF testing/conference room, and an 80 SF storage room. The Army requires one 125 SF private office, twelve workstation spaces, a 100 SF testing/conference room, a 125 SF storage room, a 36 SF network/security closet, two 100 SF unisex ADA-compliant restrooms, and a 20 SF janitorial closet. Additional specifications note that network equipment closets should be located in the private office for single-service stations or in common areas for multi-service stations.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| a. U.S. Government Lease for Real Property.pdf | ||
| 1. Proposal to Lease Space Worksheet.xlsx | XLSX spreadsheet | |
| 3. Construction and Security Specifications.pdf | ||
| 4. Janitorial Services Specification - Requirement.pdf | ||
| b. General Clause, GSA Form 3517B.pdf | ||
| 3a. Construction_Specifications_Bid_Proposal_Worksheet.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Minimum and Specific Requirements
- 1 -
Armed Forces Career Center
Minimum Gross Square Footage: 3,600 SF
Maximum Gross Square Footage: 3,944 SF
Minimum Requirements for All Locations:
1. Secondary egress for each individual office leading away from the main entry door or shared common corridor.
2. 24-hour lighted or secured parking within the lessor’s premises for 11 Government vehicles.
3. Adequate parking for service member privately owned vehicles during working hours.
4. 24-hour access to the leased spaces.
5. High-speed data service connection from the street to the building demarcation point.
USMC Specific Requirements:
1. Private Offices: One (1) private office of 125 SF within each individual Armed Forces Center; see specific requirements detailed within the construction specifications.
2. Open Space for cubicles or workstations: Space lay out to include an open area within the suite for four (4) workstations.
3. Testing/Conference Room: One (1) testing room of 80 SF with a window or a glass door facing the open area for test monitoring.
4. Storage Room: One (1) storage room of 80 SF for supplies/equipment storage, preferably in the rear of the suite.
Army Specific Requirements:
1) Private Offices: One (1) private office of 125 SF within each individual Armed Forces Center; see specific requirements detailed within the construction specifications.
Minimum and Specific Requirements
- 2 -
2) Open Space for cubicles or workstations: Space lay out to include an open area within the suite for twelve (12) workstations.
3) Testing/Conference Room: One (1) testing room of 100 SF with a window or a glass door facing the open area for test monitoring.
4) Storage Room: One (1) storage room of 125 SF for supplies/equipment storage, preferably in the rear of the suite.
1) Network/CCTV (Security) Closet: One (1) network equipment closet of approximately 36 SF for CCTV system and entry control system housing. This closet should be located in the private office if a single Service station or built into the common area if a multiple Service station.
2) Restrooms: A minimum of two (2) unisex 100 SF restroom meeting ADA specifications. Construction specifications will indicate if more than one restroom is required.
3) Janitorial Closet: One (1) janitorial equipment closet of a minimum of 20 SF, specific requirements detailed within the construction specifications.
File details come from the government source that posted it. Updated .