2. MINIMUM AND SPECIFIC REQUIREMENTS.pdf

PDF 104 KB Posted

Attached to
Recruiting Station - Marines Career Center - Gainesville, FL
Solicitation number
DACA175260000400
Issued by

About this file

This document outlines the Minimum and Specific Requirements for a United States Marine Corps (USMC) Career Center facility lease. The space requirements range from 850 to 1,628 gross square feet and include specific spatial allocations: two 125 SF private offices, an open area for two 125 SF workstations, an 86 SF testing room with monitoring visibility, a 110 SF conference room, a 75 SF storage room, and a 48 SF network/security closet. Additional mandatory requirements include secondary egress for offices, 24-hour secured parking for four government vehicles and service members' private vehicles, 24-hour facility access, and a high-speed data service connection from the street to the building demarcation point.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Minimum and Specific Requirements

- 1 -

United States Marine Corps Career Center

Minimum Gross Square Footage: 850 SF

Maximum Gross Square Footage: 1,628 SF

Minimum Requirements for All Locations:

1. Secondary egress for each individual office leading away from the main entry door or shared common corridor.

2. 24-hour lighted or secured parking within the lessor’s premises for four (4) Government vehicle.

3. Adequate parking for service member privately owned vehicles during working hours.

4. 24-hour access to the leased spaces.

5. High-speed data service connection from the street to the building demarcation point.

USMC Specific Requirements:

1. Private Offices: Two (2) private office of 125 SF within each individual Armed Forces Center; see specific requirements detailed within the construction specifications.

2. Open Space for cubicles or workstations: Space lay out to include an open area within the suite for two (2) workstation of 125 SF.

3. Testing Room: One (1) testing room of 86 SF with a window or a glass door facing the open area for test monitoring.

4. Conference Room: One (1) conference room of 110 SF.

5. Storage Room: One (1) storage room of 75 SF for supplies/equipment storage, preferably in the rear of the suite.

6. Network/CCTV (Security) Closet: One (1) network equipment closet of approximately 48 SF for CCTV system and entry control system housing. This closet should be located in the private office if a single Service station, or built into the common area if a multiple Service station.