The document is a Minimum and Specific Requirements file for a United States Marine Corps Career Center lease in Inverness, FL. The requirements specify a lease space between 1,083 and 1,425 usable square feet, with detailed specifications including one 125 SF private office, an open area for three 125 SF workstations, an 80 SF testing/conference room, an 80 SF storage room, a 30 SF security closet, a 100 SF ADA-compliant restroom, and a 20 SF janitorial closet. Additional requirements include 24-hour lighted parking for four government vehicles, adequate parking for service members and visitors, 24-hour facility access, high-speed data service connection, and secondary egress for offices. The lease will be for a five-year term with government termination rights, and a full-service lease is preferred.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Minimum and Specific Requirements
- 1 -
United States Marine Corps Career Center
Minimum Usable Square Footage: 1083 SF
Maximum Usable Square Footage: 1425 SF
Minimum Requirements for All Locations:
1. Secondary egress for each individual office leading away from the main entry door or shared common corridor.
2. 24-hour lighted or secured parking within the lessor’s premises for four (4) Government vehicles.
3. Adequate parking for service member’s privately owned vehicles during working hours as well as for visitors.
4. 24-hour access to the leased spaces.
5. High-speed data service connection from the street to the building demarcation point.
USMC Specific Requirements:
1. Private Office Space: One Private Office of 125 SF.
2. Open Space for cubicles or workstations: Space lay out to include an open area within the suite for three (3) workstations, 125 SF each.
3. Testing/Conference Room: One (1) testing room of 80 SF with a window or a glass door facing the open area for test monitoring.
4. Storage Room: One (1) storage room of 80 SF for supplies/equipment storage, preferably in the rear of the suite. The storage room will also accommodate for a communications board. An additional 30 SF shall be allocated for a separate CCTV/security closet is required.
Minimum and Specific Requirements
- 2 -
Additional Office Requirements:
1. Network/CCTV (Security) Closet: One (1) network equipment closet of approximately 30 SF for CCTV system and entry control system housing. This closet should be located within the storage room.
2. Restrooms: A minimum of ONE (1) 100 SF, located in the common area, each restroom meeting ADA specifications built to accommodate at least two occupants at one time.
3. Janitorial Closet: One (1) janitorial equipment closet of a minimum of 20 SF, specific requirements detailed within the construction specifications. The janitorial closet must be located in the common area.