Sheet1

Brand name or equal - RFQ# RML-2024141
The proposed purchase is for Brand Name or Equal products. The brand name, and modelHigh-precision Colony Picker - Singer Instruments
number, and part number of the product(s) are:
#DescriptionCatalogQty
11 each CAT# PIX-001 - PIXL instrumentPIX-0011 each
21 each CAT# PIX-MCI - 15.6" LCD touchscreen MCI for PIXLPIX-MCI1 each
31 each CAT# CAB-003 - Power Cable (Type B) Power Cable for use in USACAB-0031 each
41 each CAT# PIX-001-Q - PIXL Packing & Transit PackPIX-001-Q1 each
51 each CAT# PUL-001 - PickupLine Load a single 200m reel into PIXL to form more than 30,000 sterile, disposable tipsPUL-0011 each
61 each CAT# PET-002 - Petri Dish Adaptor (90mm) for PIXLPET-0021 each
71 each CAT# RIC-004 - Installation RZ4 Installatio and trainingRIC-0041 each
81 each CAT# SLS-002 - Lab Support (1-Year)SLS-0021 each
9Shipping FOB DesitinationSHI-0021 each
Warranty information MUST be included in the quote
Place of manufacturer must be included in the quote
Brand name - manufacturer https://www.singerinstruments.com/solution/pixl/
To be considered for award, vendors of “equal” products, including “equal” products of the brand-name manufacturer, must meet the following criteria for the salient characteristics of the above COLONY PICKING: PIXL and accessories.
Required Salient Characteristics
1Library Construction
2Colorimetric (including blue/white) Screening
3Synthetic Biology
4Protein Expression
5Strain Isolation
6Phage Display
7Enzyme Evolution
8DNA Sequencing
9Random Mutagenesis Screening
10Fluorescence Detection
11MAINTAIN PICKING ACCURACY & REPEATABILITY ACROSS UNEVEN AGAR SURFACES
12Select up to 33,000 colonies with each PickupLine
13LEDs that are configured as standard to emit: Blue, Cyan, Green, 2 intensities of UV and white light.
14Scientific grade, HD camera and filter tray
156-channel, flat-field incident illumination
16Autoclavable waste drawer for used tips
17at least 15.6’’, 1080p Full HD, LED-Backlit LCD Touch screen Monitor
18Emergency stop button
19TRANSFER EFFICIENCY Agar to agar: 99.78%
20AGAR COMPATIBILITY 1.3% -> 2%
21Load a single 200m reel into instrument to form up to 33,000 sterile, disposable tips.
22PETRI DISH ADAPTOR: 90mm: PET-002 150mm: PET-003 source bay to work with PlusPlates, 90mm or 150mm Petri dishes.
23FILTERS · 452nm: PXF-001 · 510nm: PXF-002 · 527nm: PXF-003 · 615nm: PXF-004
29Software capabilities
Multiple User profile. PIXL remembers last used settings; stores templates; and logs user actions and parameters.
Select Source Plate - Petri or PlusPlate. Pick from the whole plate or define sectors of interest.
Select Lighting Channel - Use white, or one of 5 other fluorescent channels
Detect Colonies - Filter based on: size, intensity, colour or circularity. Pick them all, or choose a sorted, or randomised subset.
Select Target Plate - Select number of replicates; on any density, in any pattern, agar or liquid.
Pick Colonies - Review your routine, estimated time and number of plates required, then press go and walk away
Export Data - Export your routine, colony information and parameters as a CSV file
30System Dimensions (H x W x D) (instrument can not exceed these dimensions) due to space limitations.
System can not exceed TECHNICAL SPECS · Length: 730mm · Width: 640mm · Height: 805mm and · Weight: 100kg
31Power requirements
Power: 240VAC at 3 Amps, 100-240VAC Compatible
32Top Light minimum requirements:
TOP LIGHT · 1x White Channel & 5x Fluorescence Channels · UV 1 (380-390 nm) · UV 2 (400-410 nm) · Blue (465-485 nm) · Cyan (490-510 nm) · Green (520-540 nm)
33Camera: minimum requirements:
CAMERA · 5MP (2448 x 2048) Resolution · USB 3.0 · 2/3” Sensor · 16mm Autofocus Liquid Lens
34Touch Screen Monitor:
Minumum requirements: 15.6’’, 1080p Full HD, LED-Backlit LCD Monitor

· Edge-to-edge glass display with anti-glare

· 10 touch projected capacitive (PCAP)

35Installation and Training
Lab Support (1-Year)
Includes free diagnosis, remote support, attended and
unattended remote access, 50% off of parts and labour, all
the latest software updates, and higher-wear machine
components replaced at no cost.
To Includes ongoing support for next 12 months support

https://www.singerinstruments.com/wp-content/uploads/2019/10/pixl_colony_picking_brochure_2019_email_3.3.pdf image1.png