| Brand name or equal - RFQ# RML-2024141 | ||||
| The proposed purchase is for Brand Name or Equal products. The brand name, and model | High-precision Colony Picker - Singer Instruments | |||
| number, and part number of the product(s) are: | ||||
| # | Description | Catalog | Qty | |
| 1 | 1 each CAT# PIX-001 - PIXL instrument | PIX-001 | 1 each | |
| 2 | 1 each CAT# PIX-MCI - 15.6" LCD touchscreen MCI for PIXL | PIX-MCI | 1 each | |
| 3 | 1 each CAT# CAB-003 - Power Cable (Type B) Power Cable for use in USA | CAB-003 | 1 each | |
| 4 | 1 each CAT# PIX-001-Q - PIXL Packing & Transit Pack | PIX-001-Q | 1 each | |
| 5 | 1 each CAT# PUL-001 - PickupLine Load a single 200m reel into PIXL to form more than 30,000 sterile, disposable tips | PUL-001 | 1 each | |
| 6 | 1 each CAT# PET-002 - Petri Dish Adaptor (90mm) for PIXL | PET-002 | 1 each | |
| 7 | 1 each CAT# RIC-004 - Installation RZ4 Installatio and training | RIC-004 | 1 each | |
| 8 | 1 each CAT# SLS-002 - Lab Support (1-Year) | SLS-002 | 1 each | |
| 9 | Shipping FOB Desitination | SHI-002 | 1 each | |
| Warranty information MUST be included in the quote | ||||
| Place of manufacturer must be included in the quote | ||||
| Brand name - manufacturer https://www.singerinstruments.com/solution/pixl/ | ||||
| To be considered for award, vendors of “equal” products, including “equal” products of the brand-name manufacturer, must meet the following criteria for the salient characteristics of the above COLONY PICKING: PIXL and accessories. | ||||
| Required Salient Characteristics | ||||
| 1 | Library Construction | |||
| 2 | Colorimetric (including blue/white) Screening | |||
| 3 | Synthetic Biology | |||
| 4 | Protein Expression | |||
| 5 | Strain Isolation | |||
| 6 | Phage Display | |||
| 7 | Enzyme Evolution | |||
| 8 | DNA Sequencing | |||
| 9 | Random Mutagenesis Screening | |||
| 10 | Fluorescence Detection | |||
| 11 | MAINTAIN PICKING ACCURACY & REPEATABILITY ACROSS UNEVEN AGAR SURFACES | |||
| 12 | Select up to 33,000 colonies with each PickupLine | |||
| 13 | LEDs that are configured as standard to emit: Blue, Cyan, Green, 2 intensities of UV and white light. | |||
| 14 | Scientific grade, HD camera and filter tray | |||
| 15 | 6-channel, flat-field incident illumination | |||
| 16 | Autoclavable waste drawer for used tips | |||
| 17 | at least 15.6’’, 1080p Full HD, LED-Backlit LCD Touch screen Monitor | |||
| 18 | Emergency stop button | |||
| 19 | TRANSFER EFFICIENCY Agar to agar: 99.78% | |||
| 20 | AGAR COMPATIBILITY 1.3% -> 2% | |||
| 21 | Load a single 200m reel into instrument to form up to 33,000 sterile, disposable tips. | |||
| 22 | PETRI DISH ADAPTOR: 90mm: PET-002 150mm: PET-003 source bay to work with PlusPlates, 90mm or 150mm Petri dishes. | |||
| 23 | FILTERS · 452nm: PXF-001 · 510nm: PXF-002 · 527nm: PXF-003 · 615nm: PXF-004 | |||
| 29 | Software capabilities | |||
| Multiple User profile. PIXL remembers last used settings; stores templates; and logs user actions and parameters. | ||||
| Select Source Plate - Petri or PlusPlate. Pick from the whole plate or define sectors of interest. | ||||
| Select Lighting Channel - Use white, or one of 5 other fluorescent channels | ||||
| Detect Colonies - Filter based on: size, intensity, colour or circularity. Pick them all, or choose a sorted, or randomised subset. | ||||
| Select Target Plate - Select number of replicates; on any density, in any pattern, agar or liquid. | ||||
| Pick Colonies - Review your routine, estimated time and number of plates required, then press go and walk away | ||||
| Export Data - Export your routine, colony information and parameters as a CSV file | ||||
| 30 | System Dimensions (H x W x D) (instrument can not exceed these dimensions) due to space limitations. | |||
| System can not exceed TECHNICAL SPECS · Length: 730mm · Width: 640mm · Height: 805mm and · Weight: 100kg | ||||
| 31 | Power requirements | |||
| Power: 240VAC at 3 Amps, 100-240VAC Compatible | ||||
| 32 | Top Light minimum requirements: | |||
| TOP LIGHT · 1x White Channel & 5x Fluorescence Channels · UV 1 (380-390 nm) · UV 2 (400-410 nm) · Blue (465-485 nm) · Cyan (490-510 nm) · Green (520-540 nm) | ||||
| 33 | Camera: minimum requirements: | |||
| CAMERA · 5MP (2448 x 2048) Resolution · USB 3.0 · 2/3” Sensor · 16mm Autofocus Liquid Lens | ||||
| 34 | Touch Screen Monitor: | |||
| Minumum requirements: 15.6’’, 1080p Full HD, LED-Backlit LCD Monitor |
· Edge-to-edge glass display with anti-glare
· 10 touch projected capacitive (PCAP)
| 35 | Installation and Training |
| Lab Support (1-Year) | |
| Includes free diagnosis, remote support, attended and | |
| unattended remote access, 50% off of parts and labour, all | |
| the latest software updates, and higher-wear machine | |
| components replaced at no cost. | |
| To Includes ongoing support for next 12 months support |