2-Antrhacite Mem - Drawings 10-12-2026.pdf

PDF 6 MB Posted

Attached to
REBID of Anthracite Memorial Park Wall Bracing Project
Solicitation number
US.258314
Issued by
Luzerne County, Pennsylvania

About this file

Summary of Anthracite Memorial Park Wall Bracing Project - Structural Drawings

This document consists of structural drawings and general notes prepared by Hemmler & Camayd Architects for the Anthracite Memorial Park Wall Bracing Project located at 74 Hill Road, Pottsville, Pennsylvania 17901. The project involves the installation of structural bracing systems to stabilize existing stone walls at the memorial park site. The work includes removal of existing temporary wall bracing, roofing, and roof framing; demolition of an existing chimney; installation of new hollow structural steel (HSS) bracing posts and outriggers; placement of concrete encasements with reinforcing steel; and epoxy-anchored connections to the existing stone wall using Hilti adhesive anchor systems. The project has been issued for construction as of October 12, 2026, with a project rebid status noted. According to the related contract opportunity, bid proposals are due by 2:00 PM on November 4, 2026, via the PennBid program, with public opening at 6:30 PM the same day. Work is scheduled to commence no later than December 1, 2026, with final completion required by March 1, 2027. A pre-bid conference will be held on October 22, 2026, at 10:00 A.M. at the project site.

The contract is structured as a single prime lump sum contract with a proposal guarantee requirement of ten percent of the bid amount. The successful contractor must provide performance and payment bonds equal to the full contract price, maintaining such bonds for twelve months after final payment. Design criteria incorporate 2021 International Building Code standards, with seismic design category B, basic wind speed of 113 MPH, and ground snow load of 50 PSF. Structural materials are specified per AISC standards for steel and ACI standards for concrete. All new steel shall receive Tnemec paint per project specifications. The project includes multiple bid options for alternative coping treatments and concrete encasement details. All project labor shall be priced in accordance with prevailing minimum wage determinations of the Pennsylvania Department of Labor and Industry. The Owner reserves the right to reject any or all bids.

View the file

Other files

File Type Posted
1-Anthracite Mem - Project Manual 10-14-2026.pdf PDF
4-Add 02 - REBID.pdf PDF
3-Add 01 - REBID-10.22.26.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

(UNLESS OTHERWISE NOTED OR SHOWN ON PLAN, THE FOLLOWING NOTES SHALL APPLY)

SYMBOL KEY/LEGEND

NEW COLUMN GRID LINE

EXISTING COLUMN GRID LINE

MOMENT CONNECTION

INDICATES SPAN OF METAL DECK.

DECK SPANS PERPENDICULAR TO

FRAMING UNLESS OTHER WISE

NOTED.

SECTION NUMBER

SECTION SHEET LOCATION

DROP-IN FRAME FOR

OPENING IN ROOF

CONSTRUCTION

(UNLESS OTHERWISE NOTED OR SHOWN ON PLAN, THE FOLLOWING NOTES SHALL APPLY)

ABBREVATIONS

ADJ.

ALT.

ATTACH.

BOTT.

BLDG.

BM.

CANT.

CLR.

CA; C.A.

CB; C.B.

COL.

CONC.

CONN.

CONT.

DIA.;

DWG.

EA.

E.F.

EL.; ELEV.

E.O.D.

E.O.S.

EQ.

ADJUSTMENT

ALTERNATIVE

ATTACHMENT

BOTTOM

BUILDING

BEAM

CANTILEVER

CENTERLINE

CLEAR

COLUMN ABOVE

COLUMN BELOW

COLUMN

CONCRETE

CONNECTION

CONTINUOUS

DIAMETER

DRAWING

EACH

EACH FACE

ELEV.ELEVATION

EDGE OF DECK

EDGE OF SLAB

EQUALLY

E.W.

EXP.

E.J.

EXT.

FIN.

FT.

FTG.

H H.P.

HOR.; HORIZ.

HSB; H.S.B.

IN.

JT.

LBS.

LLH; L.L.H.

LLV; L.L.V.

L.P.

LOC'N(S)

MAX.

MID.

MIN.

NO.

N.T.S.

O.C.

PSF

PSI

R.A.

REINF.

REQ'D

S.C.

S.O.G.

SPL.

SP.

SQ.

SYM. S

T & B

THK.

T.O.J.

T.O.S.

TYP.

U.O.N.

VERT.

W.W.F.

EACH WAY

EXPANSION

EXPANSION JOINT

EXTENSION

FINISH

FOOT/FEET

FOOTING

HANGER

HIGH POINT

HORIZONTAL

HIGH STRENGTH BOLT

INCH, INCHES

JOINT

POUNDS

LONG LEG HORIZONTAL

LONG LEG VERTICAL

LOW POINT

LOCATION(S)

MAXIMUM

MIDDLE

MINIMUM

NUMBER

NOT TO SCALE

ON-CENTER

PLATE

POUNDS PER SQUARE FOOT

POUNDS PER SQUARE INCH

ROOF DRAIN

REINFORCING

REQUIRED

SLIP CONNECTION

SLAB-ON-GRADE

SPLICE

SPACING

SQUARE

SYMMETRY

TOP AND BOTTOM

THICKNESS

TOP OF JOIST

TOP OF STEEL

TYPICAL

UNLESS OTHERWISE NOTED

VERTICAL

WELDED WIRE FABRIC

DESIGN INFORMATION

2021 INTERNATIONAL BUILDING CODE

SEISMIC DESIGN DATA

SEISMIC DESIGN (PER ASCE 7-16 Chapters 11-17 AS INDICATED IN

2021 IBC SECTION 1613)

• IBC OCCUPANCY CATEGORY = II

• SEISMIC IMPORTANCE FACTOR (IE) = 1.00

• ANALYSIS PROCEDURE = EQUIVALENT LATERAL FORCE PROCEDURE

• SITE CLASS = D (ASSUMED IN THE ABSENCE OF A SOILS REPORT)

• 0.2 SPECTRAL RESPONSE ACCELERATION (SS) = 0.136

• 1.0 SPECTRAL RESPONSE ACCELERATION (S1) = 0.044

• DAMPED DESIGN SPECTRAL RESPONSE (SDS) = 0.145

• ACCELERATION (SHORT PERIOD)

• DAMPED DESIGN SPECTRAL RESPONSE (SD1) = 0.070

• ACCELERATION (1-second PERIOD)

• SEISMIC DESIGN CATEGORY = B

WIND LOAD

WIND DESIGN (PER ASCE 7-16 Chapter 6 AS INDICATED IN

2021 IBC SECTION 1609)

• BASIC WIND SPEED (V3S) = 113 MPH

• EXPOSURE CATEGORY = B

• GUST EFFECT FACTOR (G) = 0.85

SNOW LOAD

SNOW DESIGN (PER ASCE 7-16 Chapter 7 AS INDICATED IN 2021

IBC SECTION 1608)

• GROUND SNOW LOAD (PG) = 50 PSF

• FLAT ROOF SNOW LOAD (PF) = 35 PSF

• SNOW EXPOSURE FACTOR (CE) = 1.0

• SNOW IMPORTANCE FACTOR (IS) = 1.00

• SNOW THERMAL FACTOR (Ct) = 1.0

(UNLESS OTHERWISE NOTED OR SHOWN ON PLAN, THE FOLLOWING NOTES SHALL APPLY)

1. CONCRETE WORK SHALL CONFORM WITH THE REQUIREMENTS OF THE AMERICAN CONCRETE INSTITUTE ACI 318

(LATEST EDITION).

2. UNLESS OTHERWISE INDICATED ON DRAWINGS CAST-IN-PLACE CONCRETE SHALL DEVELOP A STRENGTH OF 4,000 PSI

AT 28 DAYS.

3. REINFORCEMENT SHALL BE DEFORMED BARS ASTM DESIGNATION A-615, GRADE 60.

4. CONCRETE PROTECTION FOR REINFORCEMENT SHALL CONFORM TO LATEST A.C.I. SPECIFICATION.

5. TEMPERATURE REINFORCING SHALL BE SUFFICIENTLY EMBEDDED TO DEVELOP FULL STRENGTH IN CONCRETE WALLS

AND SLABS.

6. PROVIDE ADEQUATE TIES FOR REINFORCEMENT IN SLABS, BEAMS, PIERS AND WALLS. REINFORCEMENT TO BE HELD AT

CORRECT DISTANCE FROM FORMS AND EARTH BY STEEL CHAIRS OR TIES.

7. FOLLOW C.R.S.I. RULES FOR PLACING OF REINFORCING STEEL AND ACCESSORIES.

8. NO CONCRETE SHALL BE CAST UNTIL THE PRELIMINARY TESTS REQUIRED HAVE BEEN MADE, REPORTS THEREOF FILED

WITH THE ENGINEER, AND APPROVED. THE CONTROLLED CONCRETE TO BE USED SHALL CONFORM TO THE APPROVED DESIGN MIX OBTAINED AS A RESULT OF THE PRELIMINARY TESTS. THE USE OF ANY ADDITIVES NOT PRESENT IN THE

PRELIMINARY TEST MIX IS PROHIBITED.

9. REPRESENTATIVE TEST CYLINDERS WILL BE TAKEN FROM THE CONCRETE PLACED EACH DAY IN ACCORDANCE WITH

CONCRETE SPECIFICATIONS.

10. WELDED WIRE FABRIC SHALL HAVE A MINIMUM ULTIMATE STRENGTH OF 70,000 PSI AND SHALL CONFORM TO ASTM A-185

AND A-497.

11. MESH SHALL BE SPLICED SO THAT THE OVERLAP BETWEEN OUTERMOST CROSS WIRES OF EACH SHEET IS NOT LESS THAN THE SPACING OF THE CROSS WIRES PLUS TWO INCHES, UNLESS OTHERWISE SHOWN ON THE DRAWINGS.

12. THIS CONTRACTOR SHALL COOPERATE WITH OTHER TRADES AND WHERE REQUIRED INSTALL ALL BUILT-IN WORK, SLEEVES, INSERTS, ETC., AS REQUIRED FOR A COMPLETE JOB.

13. STRUCTURAL MEMBERS SHALL BE POURED FOR THEIR FULL DEPTHS IN ONE OPERATION. CONSTRUCTION JOINTS SUCH AS A DAY'S POUR JOINTS SHALL BE LOCATED IN THE MIDDLE THIRD OF THE SPAN, MAIN REINFORCING TO RUN THROUGH

THE JOINT, KEY AND ROUGHEN JOINTS TO EXPOSE AGGREGATE FOR CHEMICAL BOND.

14. NO HORIZONTAL JOINTS SHALL BE PLACED IN PIERS OR FOOTINGS EXCEPT AS SHOWN ON THE DRAWINGS, WITHOUT

THE APPROVAL OF THE ENGINEER.

15. BACKFILL TO BE PLACED IN 6" LAYERS AND COMPACTED TO 95% OF MAXIMUM MODIFIED DENSITY.

CAST-IN-PLACE CONCRETE GENERAL NOTES

(UNLESS OTHERWISE NOTED OR SHOWN ON PLAN, THE FOLLOWING NOTES SHALL APPLY)

1. ALL DETAILS MARKED "TYPICAL" IN THE SET OF STRUCTURAL DRAWINGS SHALL BE APPLIED THROUGHOUT THE

PROJECT AS REQUIRED TO SATISFY THE REQUIREMENTS OF THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL COORDINATE REQUIREMENTS FOR QUANTITY AND LOCATION WHERE THE "TYPICAL" DETAILS APPLY.

2. FAILURE ON THE PART OF THE CONTRACTOR TO REVIEW THE DRAWINGS OF OTHER DISCIPLINES (i.e. ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, ETC.) TOGETHER WITH THE FULL EXTENT OF THE PROJECT SPECIFICATIONS DOES NOT RELIEVE THEM OF THE RESPONSIBILITY TO FURNISH AND INSTALL ITEMS THAT ARE PART OF THEIR WORK AS INDICATED BY THE DRAWINGS AND SPECIFICATIONS OF OTHER TRADES. ALL STRUCTURAL TRADE CONTRACTORS AND SUBCONTRACTORS ARE PROHIBITED FROM EXCLUDING STRUCTURAL WORK FROM THEIR CONTRACT NOT SHOWN IN

THE STRUCTURAL DRAWINGS.

3. THE STRUCTURAL DRAWINGS FOR THIS PROJECT ARE NOT ISSUED FOR BID OR CONSTRUCTION UNLESS THE INDIVIDUAL

SHEETS ARE IDENTIFIED AS "ISSUED FOR BID" OR "ISSUED FOR CONSTRUCTION."

4. THESE DRAWINGS DO NOT INCLUDE INFORMATION PERTAINING TO WEATHERPROOFING OR DRAINAGE OF STORM WATER, SUBSURFACE WATER, INTERIOR SURFACES, OR ANY OTHER AREAS THAT MAY BE IN CONTACT WITH WATER OR FLUIDS OF ANY KIND. ALL TREATMENTS OF SURFACES INCLUDING PITCH, SLOPE, FINISHES, WATERPROOFING, ETC. AND CONVEYANCE OF ANY FLUIDS AWAY FROM THE STRUCTURE IS INDICATED ELSEWHERE IN THE CONTRACT DOCUMENTS.

STRUCTURAL SLABS, BALCONIES, PITS, STAIRS ROOFS, WALLS, AND MEMBERS DEPICTED ON THE PLANS, SECTIONS, AND DETAILS ARE SHOWN FOR THE SOLD PURPOSE OF COMMUNICATING STRUCTURAL INFORMATION AND MAY NOT BE ACCURATE REGARDING THE INTENT OF HOW FLUIDS FLOW AROUND AND AWAY FROM THE STRUCTURE. ANY INFORMATION SHOWN ON THE STRUCTURAL DRAWINGS RELATED TO SYSTEMS THAT CONTROL FLUID FLOW AGAINST THE STRUCTURAL ELEMENTS IS DIAGRAMMATIC AND MUST BE CONFIRMED WITH THE FULL REQUIREMENTS OF THE

BUILDING CODE AND THE CONTRACT DOCUMENTS.

GENERAL INFORMATION

(UNLESS OTHERWISE NOTED OR SHOWN ON PLAN, THE FOLLOWING NOTES SHALL APPLY)

1. EXCEPT WHERE INDICATED ON THE DRAWINGS, POST-INSTALLED ANCHORS SHALL CONSIST OF THE FOLLOWING

ANCHOR TYPES AS PROVIDED BY HILTI, INC. CONTACT HILTI AT (800)879-8000 FOR PRODUCT RELATED QUESTIONS.

2. ANCHOR TYPES:

• 2.1. ANCHORAGE TO CONCRETE:

• - ADHESIVE ANCHORS FOR CRACKED AND UNCRACKED CONCRETE USE:

• -- HILTI HIT-HY 200 SAFE SET SYSTEM WITH HILTI HOLLOW HIT-Z ROD PER ICC ESR-3187

• -- HILTI HIT-HY 200 SAFE SET SYSTEM WITH HILTI HOLLOW DRILL BIT SYSTEM WITH HAS-E

THREADED ROD PER ICC ESR-3187

• -- HILTI HIT-RE 500 -SD EPOXY ADHESIVE ANCHORING SYSTEM WITH HAS-E THREADED ROD PER ICC

ESR-2322 FOR SLOW CURE APPLICATIONS

• - MEDIUM DUTY MECHANICAL ANCHORS FOR CRACKED AND UNCRACKED CONCRETE USE:

• -- HILTI KWIK HUS EZ AND KWIK HUS EX-I SCREW ANCHORS PER ICC ESR-3027.

• -- HILTI KWIK BOLT-TZ EXPANSION ANCHORS PER ICC ESR-1917

• -- HILTI KWIK BOLT 3 EXPANSION ANCHORS (UNCRACKED CONCRETE ONLY) PER ISS ESR-2302

• - HEAVY DUTY MECHANICAL ANCHORS FOR CRACKED AND UNCRACKED CONCRETE USE:

• -- HILTI HDA UNDERCUT ANCHORS PER ICC ESR-1546

• -- HILTI HSL-3 EXPANSION ANCHORS PER ICC ESR-1545

• 2.2 REBAR DOWELING INTO CONCRETE:

• - ADHESIVE ANCHORS FOR CRACKED AND UNCRACKED CONCRETE USE:

• -- HILTI HIT-HY 200 SAFE SET SYSTEM WITH HILTI HOLLOW DRILL BIT SYSTEM WITH CONTINUOUSLY

DEFORMED REBAR PER ICC ESR-3187

• -- HILTI HIT-RE 500-SD EPOXY ADHESIVE ANCHORING SYSTEM WITH CONTINUOUSLY DEFORMED

REBAR PER ICC ESR-2322

• 2.3 ANCHORAGE TO SOLID GROUTED MASONRY:

• - ADHESIVE ANCHORS USE:

• -- HILTI HILTI HIT-HY 270 MASONRY ADHESIVE ANCHORING SYSTEM

• -- STEEL ANCHOR ELEMENT SHALL BE HILTI HAS-E CONTINUOUSLY THREADED ROD OR

CONTINUOUSLY DEFORMED STEEL REBAR

• - MECHANICAL ANCHORS USE:

• -- HILTI KWIK BOLT-3 EXPANSION ANCHORS PER ICC ESR-1385

• 2.4 ANCHORAGE TO HOLLOW / MULTI-WYTHE MASONRY:

• - ADHESIVE ANCHORS USE:

• -- HILTI HIT-HY 270 MASONRY ADHESIVE ANCHORING SYSTEM PER ICC ESR-3342

• -- STEEL ANCHOR ELEMENT SHALL BE HILTI HAS-E CONTINUOUSLY THREADED ROD OR

CONTINUOUSLY DEFORMED STEEL REBAR

• -- THE APPROPRIATE SIZE SCREEN TUBE SHALL BE USED PER ADHESIVE MANUFACTURER'S

RECOMMENDATIONS.

3. ANCHOR CAPACITY USED IN DESIGN SHALL BE BASED ON THE TECHNICAL DATA PUBLISHED BY HILTI OR SUCH OTHER

METHOD AS APPROVED BY THE STRUCTURAL ENGINEER OF RECORD. SUBSTITUTION REQUESTS FOR ALTERNATE PRODUCTS MUST BE APPROVED IN WRITING BY THE STRUCTURAL ENGINEER OF RECORD PRIOR TO USE. CONTRACTOR SHALL PROVIDE CALCULATIONS DEMONSTRATING THAT THE SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING THE PERFORMANCE VALUES OF THE SPECIFIED HILTI PRODUCT. SUBSTITUTIONS WILL BE EVALUATED BY THEIR HAVING AN ICC ESR SHOWING COMPLIANCE WITH THE RELEVANT BUILDING CODE FOR SEISMIC USES, LOAD RESISTANCE, INSTALLATION CATEGORY, AND AVAILABILITY OF COMPREHENSIVE INSTALLATION INSTRUCTIONS. ADHESIVE ANCHOR EVALUATION WILL ALSO CONSIDER CREEP, IN-SERVICE TEMPERATURE AND INSTALLATION TEMPERATURE.

4. INSTALL ANCHORS PER THE MANUFACTURERS INSTRUCTIONS, AS INCLUDED IN THE ANCHOR PACKAGING

5. OVERHEAD ADHESIVE ANCHORS MUST BE INSTALLED USING THE HILTI PROFI SYSTEM.

6. THE CONTRACTOR SHALL ARRANGE ANCHOR MANUFACTURER'S REPRESENTATIVE TO PROVIDE ONSITE INSTALLATION

TRAINING FOR ALL OF THEIR ANCHORING PRODUCTS SPECIFIED. THE STRUCTURAL ENGINEER MUST RECEIVE DOCUMENTED CONFIRMATION THAT ALL OF THE CONTRACTOR'S PERSONNEL WHO WILL INSTALL ANCHORS ARE

TRAINED PRIOR TO THE COMMENCEMENT OF INSTALLING ANCHORS.

7. ANCHOR CAPACITY IS DEPENDENT UPON SPACING BETWEEN ADJACENT ANCHORS AND PROXIMITY OF ANCHORS TO EDGE OF CONCRETE. INSTALL ANCHORS IN ACCORDANCE WITH SPACING AND EDGE CLEARANCES INDICATED ON THE

DRAWINGS.

8. EXISTING REINFORCING BARS IN THE CONCRETE STRUCTURE MAY CONFLICT WITH SPECIFIC ANCHOR LOCATIONS.

UNLESS OTHERWISE NOTED ON THE DRAWINGS THAT THE BARS CAN BE CUT, THE CONTRACTOR SHALL REVIEW THE EXISTING STRUCTURAL DRAWINGS AND SHALL UNDERTAKE TO LOCATE THE POSITION OF THE REINFORCING BARS AT THE LOCATIONS OF THE CONCRETE ANCHORS, HILTI PS 200 FERROSCAN, HILTI PS 1000 X-SCAN, GPR SCAN, X-RAY, CHIPPING OR OTHER MEANS. DESTRUCTIVE INVESTIGATIVE METHODS MUST BE APPROVED BY THE

ARCHITECT/ENGINEER OF RECORD.

POST-INSTALLED ANCHOR GENERAL NOTES

(UNLESS OTHERWISE NOTED OR SHOWN ON PLAN, THE FOLLOWING NOTES SHALL APPLY)

1. CONTRACTOR SHALL PROVIDE LAYOUT DRAWINGS AND CALCULATIONS FOR SHORING AND BRACING SYSTEM AND

OTHER DATA, AS REQUIRED, PREPARED AND SEALED BY A REGISTERED PROFESSIONAL ENGINEER LICENSED IN THE

STATE OF PENNSYLVANIA. SUBMIT TO ARCHITECT ONE WEEK PRIOR TO THE START OF WORK.

2. SHORING AND BRACING SHALL COMPLY WITH THE LOCAL BUILDING CODE AND ORDINANCES OF THE LOCAL GOVERNING

AUTHORITIES.

3. INSPECTION FOR STRUCTURAL STABILITY SHALL BE PROVIDED BY AN APPROVED LICENSED ENGINEER EMPLOYED BY

THE CONTRACTOR, AS REQUIRED BY LOCAL GOVERNING AUTHORITIES.

4. SUBMIT WEEKLY FIELD OBSERVATION REPORTS TO ARCHITECT DURING THE DURATION OF THE SHORING OPERATION.

5. BENCHMARKS ARE TO BE ESTABLISHED BEFORE EXCAVATIONS AND RESURVEYED WEEKLY BY A LICENSED LAND

SURVEYOR EMPLOYED BY THE CONTRACTOR.

6. BRACING SHALL BE LOCATED TO CLEAR NEW CONSTRUCTION AND OTHER PERMANENT WORK.

7. MAINTAIN SHORING AND BRACING UNTIL STRUCTURAL ELEMENTS ARE REBRACED BY OTHER BRACING OR UNTIL

PERMANENT CONSTRUCTION IS IN PLACE.

SHORING AND BRACING NOTES

(UNLESS OTHERWISE NOTED OR SHOWN ON PLAN, THE FOLLOWING NOTES SHALL APPLY)

1. STRUCTURAL STEEL SHALL CONFORM TO THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) STEEL

CONSTRUCTION MANUAL AND THE SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS (2010).

2. UNLESS OTHERWISE NOTED, ALL MATERIALS SHALL BE IN ACCORDANCE WITH THE FOLLOWING SPECIFICATIONS:

A. MEMBER ASTM MINIMUM STRENGTH

ROLLED SHAPES A992 50 KSI

OTHER ROLLED PLATES A36 36 KSI

STRUCTURAL TUBING A500 (GRADE B) 46 KSI

STEEL PIPE A500 (GRADE B) 42 KSI

CONNECTION BOLTS A325 92 KSI

ANCHOR BOLTS F1554 ----

THREADED RODS A36 36 KSI

NON-SHRINK GROUT C1107 8,000 PSI

3. CONNECTIONS SHALL BE SHEAR TYPE CONNECTIONS AND DESIGNED BY THE FABRICATOR IN ACCORDANCE WITH THE AISC FOURTEENTH EDITION SPECIFICATIONS. MINIMUM BOLT DIAMETER SHALL BE 3/4" UNLESS OTHERWISE NOTED.

BOLTS SHALL BE SHEAR/BEARING TYPE BOLTS AND BE "SNUG-TIGHT". STEEL BEAM CONNECTIONS SHALL BE DESIGNED TO SUPPORT A MINIMUM OF ONE HALF THE MAXIMUM TOTAL UNIFORM LOAD FOR PARTICULAR BEAM AND SPAN

CONDITION AS DEFINED BY THE AISC MANUAL OF STEEL CONSTRUCTION.

4. WELDING SHALL BE IN ACCORDANCE WITH AMERICAN WELDING SOCIETY (AWS) SPECIFICATION D1.1 USING E7OXX ELECTRODES. UNLESS OTHERWISE NOTED, PROVIDE CONTINUOUS MINIMUM SIZED FILLET WELDS PER AISC

REQUIREMENTS. FILLER MATERIALS SHALL HAVE A MINIMUM YIELD STRENGTH OF 58 KSI.

5. PROVIDE 1/8" CAP PLATE FOR ALL OPEN ENDS OF HSS MEMBERS. INCREASE CAP PLATE THICKNESS TO 3/4" FOR ANY LOCATIONS WHERE FRAMING BEARS ON THE COLUMN CAP. ANY VENT HOLES REQUIRED IN THE TUBE WALLS FOR WELDING SHOULD BE PLACED IN NON-VISIBLE LOCATIONS FOR EXPOSED MEMBERS IF POSSIBLE.

6. HOLES IN STEEL BEAMS SHALL BE DRILLED OR PUNCHED. ALL SLOTTED HOLES SHALL BE PROVIDED WITH SMOOTH

EDGES. BURNING OF HOLES AND TORCH CUTTING AT THE SITE IS NOT PERMITTED.

7. THE STRUCTURAL STEEL ERECTOR SHALL PROVIDE TEMPORARY GUYING AND BRACING AS REQUIRED. COLUMNS, ANCHOR BOLTS, BASE PLATES, ETC. HAVE BEEN DESIGNED FOR THE FINAL COMPLETE CONDITION, AND HAVE NOT BEEN INVESTIGATED FOR POTENTIAL LOADINGS ENCOUNTERED DURING STEEL ERECTION AND CONSTRUCTION. ANY INVESTIGATION OF THE COLUMNS, ANCHOR BOLTS, FRAMING, ETC. FOR ADEQUACY DURING THE STEEL ERECTION AND

CONSTRUCTION PROCESS IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR.

8. THE OWNER WILL HIRE AN INDEPENDENT TESTING AGENCY TO PROVIDE SPECIAL INSPECTIONS OF THE BOLTING, WELDING, AND OTHER ITEMS IN ACCORDANCE WITH THE LATEST BUILDING CODES HAVING JURISDICTION.

9. REINFORCING SHALL BE PROVIDED AT CONNECTIONS WHERE CUTS HAVE REDUCED THE SHEAR OR MOMENT CAPACITY BELOW THAT REQUIRED TO SUSTAIN THE REACTION. FLANGES AND WEB ARE TO BE REINFORCED WHERE THE LOCAL

CAPACITY TO SUSTAIN LOAD IS INADEQUATE.

10. MISCELLANEOUS IRON CONTRACTOR TO PROVIDE MISCELLANEOUS STEEL SHOWN ON ARCHITECTURAL DRAWINGS

THAT IS NOT SHOWN ON STRUCTURAL DRAWINGS.

11. ALL STEEL USED IN THE FABRICATION OF EXPOSED STRUCTURAL STEEL, INCLUDING CONNECTIONS, SHALL BE CONSIDERED ARCHITECTURALLY EXPOSED STRUCTURAL STEEL AND WILL BE SUBJECT TO THE OF SECTION 10 OF THE AISC CODE OF STANDARD PRACTICE FOR ALL STEEL BUILDINGS AND BRIDGES, MARCH 18, 2005.

12. AT LOCATIONS ON THE ARCHITECTURAL DRAWINGS OR OTHER TRADES WHERE A STEEL ANGLE OR PLATE IS SHOWN DIAGRAMMATICALLY AND REFERENCE IS MADE TO THE STRUCTURAL DRAWINGS FOR SIZE, PROVIDE MINIMUM THICKNESS OF 3/8" MATERIAL AND PLATE WIDTH OR ANGLE SIZE AS SCALED FOR THE DRAWINGS. INSTALL THE PLATE

OR ANGLE TO THE EXTENT REQUIRED TO ACCOMPLISH A COMPLETE JOB.

STRUCTURAL STEEL GENERAL NOTES

(UNLESS OTHERWISE NOTED OR SHOWN ON PLAN, THE FOLLOWING NOTES SHALL APPLY)

1. FOUNDATION DESIGN CRITERIA IS ASSUMED IN ABSENCE OF GEOTECHNICAL SOILS REPORT.

2. FOOTINGS HAVE BEEN DESIGNED FOR AN ASSUMED ALLOWABLE SOIL BEARING CAPACITY OF 1 TON PER SQUARE FOOT

(2,000 PSF) IN ABSENCE OF A GEOTECHNICAL REPORT.

3. MINIMUM DEPTH PER THE SOILS REPORT REQUIRED FOR FROST PROTECTION TO BOTTOM OF FOUNDATION =(-4'-0"). THIS

APPLIES TO ALL FOUNDATIONS.

4. BACKFILL SHALL BE BROUGHT UP EQUALLY ON BOTH SIDES OF FOUNDATION WALLS UNTIL THE FINAL ELEVATION IS

ACHIEVED. VARIATIONS SHALL NOT EXCEED 2'-0" BETWEEN BACKFILL ELEVATIONS ON EITHER SIDE WITHOUT

ENGINEER'S APPROVAL.

5. WHEN STEPPING WALL FOUNDATIONS THE MAXIMUM STEP SHALL BE ONE VERTICALLY TO TWO HORIZONTALLY WHERE

ELEVATIONS CHANGE.

6. LOCATIONS OF FOOTING STEPS SHOWN ON THE FOUNDATION PLAN ARE APPROXIMATE. THE GENERAL CONTRACTOR SHALL FIELD VERIFY EXACT GRADE LOCATIONS AROUND THE BUILDING AND LOCATE ANY FOOTING STEPS ACCORDINGLY IN ORDER TO MAINTAIN A PROPER FROST DEPTH COVER AT ALL LOCATIONS, UNLESS OTHERWISE NOTED

ON THE DRAWINGS.

FOUNDATION DESIGN AND CONSTRUCTION CRITERIA

(UNLESS OTHERWISE NOTED OR SHOWN ON PLAN, THE FOLLOWING NOTES SHALL APPLY)

1. THE SURFACE OF THE EXPOSED SUB-GRADE SHALL BE INSPECTED BY PROBING OR TESTING TO CHECK FOR POCKETS

OF SOFT OF UNSUITABLE MATERIAL. EXCAVATE UNSUITABLE SOIL AS DIRECTED BY THE ON-SITE GEOTECHNICAL

ENGINEER AND/OR TESTING AGENCY.

2. FILL ALL EXCAVATED AREAS WITH APPROVED CONTROLLED FILL. PLACE IN 12 INCH MAXIMUM LOOSE LIFTS AND COMPACT TO A MINIMUM OF 95% OF THE MAXIMUM DRY DENSITY IN ACCORDANCE WITH ASTM D-1557.

3. ALL CONTROLLED FILL MATERIAL SHALL BE A SELECT GRANULAR MATERIAL FREE FROM ALL ORGANICS OR OTHERWISE DELETERIOUS MATERIAL WITH NOT MORE THAN 20% BY WEIGHT PASSING A NO. 200 SIEVE (CLASSIFIED AS SC, SM, SP OR BETTER IN ACCORDANCE WITH THE UNIFIED SOIL CLASSIFICATION SYSTEM) AND WITH A PLASTICITY INDEX NOT

EXCEEDING 6%.

4. PROVIDE FIELD DENSITY TESTS FOR EACH 3,000 S.F. OF BUILDING AREA FOR EACH LIFT OF CONTROLLED FILL.

5. EXCAVATIONS SHALL BE KEPT DRY BY PUMPING UNTIL UNDERGROUND CONSTRUCTION IS COMPLETE.

6. LOOSENED BEARING SOILS SHALL BE RECOMPACTED WITH A SMALL VIBRATORY PLATE COMPACTOR PRIOR TO

PLACEMENT OF REINFORCING BARS.

7. ALL FOUNDATION EXCAVATIONS SHALL BE INSPECTED BY THE GEOTECHNICAL ENGINEER PRIOR TO CONCRETE

PLACEMENT. ALL SOFTENED OR OTHERWISE UNSUITABLE BEARING MATERIALS SHALL BE REMOVED AND REPLACED

WITH LOAD-BEARING FILL OR WITH LEAN CONCRETE (2000 PSI).

8. THE CONTRACTOR SHALL LAYOUT THE ENTIRE BUILDING AND FIELD VERIFY ALL DIMENSIONS PRIOR TO EXCAVATION.

SITE PREPARATION GENERAL NOTES

(UNLESS OTHERWISE NOTED OR SHOWN ON PLAN, THE FOLLOWING NOTES SHALL APPLY)

1. DIMENSIONS AND ELEVATIONS OF EXISTING CONDITIONS SHOWN ON THE STRUCTURAL DRAWINGS ARE BASED ON

LIMITED AVAILABLE INFORMATION CONTAINED IN EITHER VARIOUS ORIGINAL DESIGN AND CONSTRUCTION DOCUMENTS OR FIELD SURVEY. ACTUAL FIELD CONDITIONS NEED TO BE CONFIRMED BY THE CONTRACTOR PRIOR TO THE START OF

WORK.

2. THE CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS BY ACTUAL MEASUREMENT PRIOR TO BEGINNING WORK, AND WHEN FEASIBLE, PRIOR TO SHOP DRAWING SUBMITTALS. ANY AND ALL DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR

TO COORDINATE SAID DISCREPANCIES WITH ALL SUBCONTRACTORS AND MATERIAL SUPPLIERS.

3. DURING CONSTRUCTION THE CONTRACTOR MAY ENCOUNTER EXISTING CONDITIONS WHICH ARE NOT KNOWN OR ARE AT VARIANCE WITH THE PROJECT DOCUMENTS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ALL UNFORESEEN AND DEVIATING CONDITIONS INCLUDING, BUT NOT LIMITED TO: SIZES OR DIMENSIONS OTHER THAN THOSE SHOWN, DAMAGE OR DETERIORATION TO MATERIALS AND COMPONENTS AND CONDITIONS OF INSTABILITY OR LACK OF

SUPPORT.

4. THE CONTRACTOR SHALL PROVIDE TEMPORARY SHORING AND BRACING AND MAKE SAFE ALL EXISTING BUILDING CONSTRUCTION AND/OR ADJACENT PROPERTY AS PROJECT CONDITIONS REQUIRE. DESIGN OF TEMPORARY SHORING AND BRACING SHALL BE PERFORMED AND OVERSEEN BY A LICENSED ENGINEER EMPLOYED BY THE CONTRACTOR.

5. WHERE NEW CONSTRUCTION IS REQUIRED TO SUPPORT THE EXISTING FRAMING AND/OR CONSTRUCTION THE CONTRACTOR IS TO ENSURE ALL EXISTING FRAMING IS SHORED AND BRACED PRIOR TO INSTALLATION OF THE NEW

STRUCTURAL SUPPORT SYSTEM.

EXISTING CONDITIONS GENERAL NOTES

(UNLESS OTHERWISE NOTED OR SHOWN ON PLAN, THE FOLLOWING NOTES SHALL APPLY)

TESTING: OWNER SHALL ENGAGE A QUALIFIED INDEPENDENT TESTING AND INSPECTING AGENCY TO PERFORM THE

FOLLOWING SERVICES:

1. INSPECTION AND TESTING OF ALL STRUCTURAL FILL WITH REPORTS SUBMITTED TO THE ARCHITECT STATING

COMPLIANCE OR NONCOMPLIANCE WITH PERCENT COMPACTION REQUIREMENTS.

2. SPECIAL INSPECTIONS FOR EXISTING SITE SOIL CONDITIONS, FILL PLACEMENT AND LOAD-BEARING REQUIREMENTS

SHALL BE PERFORMED IN ACCORDANCE WITH SECTION 1704.7 OF IBC.

3. CONCRETE AND REINFORCEMENT: SHALL BE INSPECTED PER THE REQUIREMENTS OF IBC TABLE 1704.4.

4. STRUCTURAL STEEL: STRUCTURAL STEEL MEMBERS AND CONNECTIONS SHALL BE INSPECTED PER THE REQUIREMENTS

OF IBC TABLE 1704.3.

5. WRITTEN REPORTS SHALL BE SUBMITTED TO THE ARCHITECT STATING COMPLIANCE OR NONCOMPLIANCE WITH THE

DESIGN DOCUMENTS. ALL REPORTS SHALL BE SIGNED AND SEALED BY A LICENSED ENGINEER FROM THE STATE OF

PENNSYLVANIA.

6. FAILURE TO RETAIN A TESTING AGENCY TO PERFORM THE REQUIRED SERVICES SPECIFIED ABOVE, OR FAILURE TO SUBMIT SIGNED AND SEALED REPORTS, INDICATES NONCOMPLIANCE WITH THE CONTRACT DOCUMENTS.

7. SEE ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING CONSTRUCTION DOCUMENTS FOR ADDITIONAL NON-

STRUCTURAL SPECIAL INSPECTION ITEMS.

STATEMENT OF TESTING

AND SPECIAL INSPECTION REQUIREMENTS

hemmler & camayd architects, ltd.

512 Lackawanna Avenue, Scranton, PA 18503

C

IV

IL

S T R U C T U R A L

M E P /F P

570-961-1302 voice 570-9613919 fax www.hc-architects.com checked:

drawn:

reviewed:

Copyright 2025

S he et In fo rm at io n R e vi si on s P ro je ct N a m e

L o ca tio n A

/E T ea m project no.:

project date:

R e v

D a te

D e s c ri p ti o n

/1

/2

:0 :3

P

M

A N

T H

R A

C

IT

E M

E M

O R

IA

L P

A R

K W

A L L B

R A

C

IN

G P

R O

JE

C

T

H

IL

L R

O A

D

P O

T T

S V

IL

L E

P

E N

N S

Y L V

A N

IA

S001

G E

N E

R A

L N

O T

E S

D

E S

IG

N

C R

IT

E

R

IA

TJB

MJS

JK

25.034

Issue Date

/0

/2

IS

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

/1

2/

P R

O

JE

C T

R E

B

ID

HSS8x8x3/8 BRACE

POST; TYP.

S300

EXISTING STONE

WALL, TYP.

EXISTING STONE

WALL, TYP.

FR

A

M E

FR

A

M E

S300

TOP OF EXISTING WALL SHALL BE

CLEANED OF LOOSE DEBRIS AND

CAPPED WITH 2x NAILER AND

METAL COPING.

EX. CHIMNEY TO BE DEMOLISHED DOWN TO

12" ABOVE EXISTING ADJACENT T/WALL

ELEVATION. REMOVE LOOSE DEBRIS AND CAP

WITH 2x NAILER AND METAL COPING.

REMOVE EXISTING TEMPORARY

WALL BRACING

REMOVE EXISTING ROOFING,

ROOF FRAMING, AND MISC.

BLOCKING AT TOP OF WALL.

PATCH AND REPAIR AS REQ'D.

hemmler & camayd architects, ltd.

512 Lackawanna Avenue, Scranton, PA 18503

C

IV

IL

S T R U C T U R A L

M E P /F P

570-961-1302 voice 570-9613919 fax www.hc-architects.com checked:

drawn:

reviewed:

Copyright 2025

S he et In fo rm at io n R e vi si on s P ro je ct N a m e

L o ca tio n A

/E T ea m project no.:

project date:

R e v

D a te

D e s c ri p ti o n

/1

/2

:0 :3

P

M

A N

T H

R A

C

IT

E M

E M

O R

IA

L P

A R

K W

A L L B

R A

C

IN

G P

R O

JE

C

T

H

IL

L R

O A

D

P O

T T

S V

IL

L E

P

E N

N S

Y L V

A N

IA

S100

W A

LL

B

R A

C

IN

G P

LA

N

TJB

MJS

JK

25.034

Issue DateSCALE: 1/8" = 1'-0"

WALL BRACING PLAN

1. ALL NEW STEEL SHALL RECEIVE TNEMEC PAINT PER PROJECT SPECIFICATIONS

2. COORDINATE WITH EXISTING CONDITIONS OR NOTIFY ARCHITECT / ENGINEER OF ANY DISCREPANCIES.

/0

/2

IS

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

REMOVE EXISING SPRAY

INSULATION DOWN TO

SUBSTRATE (MASONRY / STONE,

WOOD) - REMOVE AT EACH

GABLE END RECEIVING NEW

WALL BRACING

PHOTO VIEWS (SEE ABOVE)

BID OPTION #5:

/1

2/

P R

O

JE

C T

R E

CONCRETE ENCASEMENT

1/2" Ø SHEAR STUDS

@ 16" o.c. ALL SIDES

(4) #6 VERTICAL BARS

#3 TIES @ 8" o.c.

(5) #5 BARS EACH WAY

L4x4x5/16x0'-9" @ 48" o.c. MAX. w/ (2) 5/8"Ø THREADED RODS w/ HILTI HIT-

HY 270 EPOXY INTO EXISTING WALL

GRADE

5'-0"SQUARE

1' -0

3/4" BASEPLATE w/ (4)

3/4"Ø ANCHOR RODS

1'-8"

COLUMNCOLUMN

CONCRETE ENCASEMENT

1/2" Ø SHEAR STUDS

@ 16" o.c. ALL SIDES

(4) #6 VERTICAL BARS

#3 TIES @ 8" o.c.

(5) #5 BARS EACH WAY

GRADE

5'-0"SQUARE

1' -0

3/4" BASEPLATE w/ (4)

3/4"Ø ANCHOR RODS

1'-8"

4' -0

"M

IN

H S

S 8x

8x 3/

H S

S 8x

8x 3/

HSS8x8x3/8

HSS8x 8x

3/8

HSS8x8x3/8

MITER w/ FULL-PENETRATION

WELD (TYP.)

V.I.F.

17'-0 1/2"

'-1

1"

HSS8x8x1/4 OUTRIGGER (TYP.)

NOTE:

ALL DIMENSIONS/GEOMETRY OF EXISTING WALL ARE

TO BE VERIFIED IN FIELD BEFORE START OF WORK. (TYP.)

3/4" PLATES w/ (4)

3/4"Ø BOLTS EACH

SIDE OF HSS

3/4" PLATES w/ (4)

3/4"Ø BOLTS EACH

SIDE OF HSS

3/4" END PLATES w/ (4)

3/4"Ø BOLTS EACH SIDE

OF HSS.

COLUMN COLUMN

CONCRETE ENCASEMENT

1/2" Ø SHEAR STUDS

@ 16" o.c. ALL SIDES

(4) #6 VERTICAL BARS

#3 TIES @ 8" o.c.

(5) #5 BARS EACH WAY

GRADE

5'-0"SQUARE

1' -0

3/4" BASEPLATE w/ (4)

3/4"Ø ANCHOR RODS

1'-8"

CONCRETE ENCASEMENT

1/2" Ø SHEAR STUDS

@ 16" o.c. ALL SIDES

#3 TIES @ 8" o.c.

(5) #5 BARS EACH WAY

GRADE

5'-0"SQUARE

1' -0

3/4" BASEPLATE w/ (4)

3/4"Ø ANCHOR RODS

1'-8"

4' -0

"M

IN

(4) #6 VERTICAL BARS

L4x4x3/8x0'-9" @ 48" o.c. MAX. w/ (2) 5/8"Ø THREADED RODS w/ HILTI HIT-

HY 270 EPOXY INTO EXISTING WALL

H S

S 8x

8x 3/

HSS8x8x3/8

MITER w/ FULL-PENETRATION

WELD (TYP.)

H S

S 8x

8x 3/

HSS8x 8x

3/8 HSS8x8x3/8

'-1

3/

V.I.F.

17'-0 1/2"

HSS8x8x1/4 OUTRIGGER

(TYP.)

NOTE:

ALL DIMENSIONS/GEOMETRY OF EXISTING WALL ARE

TO BE VERIFIED IN FIELD BEFORE START OF WORK. (TYP.)

3/4" END PLATES w/

(4) 3/4"Ø BOLTS EACH

SIDE OF HSS

3/4" END PLATES w/ (4) 3/4"Ø

BOLTS EACH SIDE OF HSS

3/4" PLATES w/ (4)

3/4"Ø BOLTS EACH

SIDE OF HSS

VARIES; V.I.F.

±2'-6"

(2) 5/8"⌀ THREAD ROD DRILLED

AND EPOXIED WITH HILTI HIT-HY

270 INTO EXISTING STONE WALL.

(MIN. EMBED. 6")

HSS OUTRIGGER

GRADE

CONCRETE ENCASEMENT; SEE

ELEVATIONS FOR ADDITIONAL

INFORMATION.

CONCRETE FOOTING; SEE

ELEVATIONS FOR ADDITIONAL

INFORMATION

1/8" CLOSURE PLATE

EXISTING STONE WALL; V.I.F.

HORIZONTAL SLOTTED HOLES

WITH (2) 3/4"⌀ BOLTS. WELD

ANGLE INTO FINAL POSITION.

BOTTOM OF NEW FOUNDATIONS TO

MATCH EX CONCRETE WALL

FOUNDATION

EXISTING WALL

FOUNDATION; SIZE

VARIES V.I.F.

HSS COLUMN

#5 DOWELS AT 12" O.C. DRILL AND EPOXY WITH

HILTI HY HIT-200 FOR CONCRETE FOUNDATION

(USE HILTI HIT-HY 270 FOR STONE FOUNDATION)

0'-8" MIN.

V .I.

F.

hemmler & camayd architects, ltd.

512 Lackawanna Avenue, Scranton, PA 18503

C

IV

IL

S T R U C T U R A L

M E P /F P

570-961-1302 voice 570-9613919 fax www.hc-architects.com checked:

drawn:

reviewed:

Copyright 2025

S he et In fo rm at io n R e vi si on s P ro je ct N a m e

L o ca tio n A

/E T ea m project no.:

project date:

R e v

D a te

D e s c ri p ti o n

/1

/2

:0 :3

P

M

A N

T H

R A

C

IT

E M

E M

O R

IA

L P

A R

K W

A L L B

R A

C

IN

G P

R O

JE

C

T

H

IL

L R

O A

D

P O

T T

S V

IL

L E

P

E N

N S

Y L V

A N

IA

S300

B R

A C

IN

G

S E

C T

IO

N

S

TJB

MJS

JK

25.034

Issue Date

SCALE: 3/4" = 1'-0"S300

FRAME #2 ELEVATION2

SCALE: 3/4" = 1'-0"S300

FRAME #1 ELEVATION1

/0

/2

IS

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

SCALE: 3/4" = 1'-0"

TYPICAL WALL BRACING DETAIL

CLEAN AND

RE-POINT - EXTENT

AS INDICATED

ADD ALTERNATE #2

A D

D E

N D

U M

/1 8/

CLEAN AND

RE-POINT - EXTENT

AS INDICATED

ADD ALTERNATE #1

BID OPTION #1 BID OPTION #2

COPING BID OPTION #3

COPING BID OPTION #4

/1

2/

P R

O

JE

C T

R E

File details come from the government source that posted it. Updated .